Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2013 Jul 17.
Published in final edited form as: Hypertens Res. 2009 Mar 27;32(5):404–410. doi: 10.1038/hr.2009.32

A 15-year longitudinal study on ambulatory blood pressure tracking from childhood to early adulthood

Zhibin Li 1, Harold Snieder 1,2,3, Gregory A Harshfield 1, Frank A Treiber 1,4, Xiaoling Wang 1
PMCID: PMC3713484  NIHMSID: NIHMS483140  PMID: 19325561

Abstract

This study evaluates the tracking stability of office blood pressure (BP), ambulatory BP (ABP), BP variability (BPV) and nocturnal BP drops (dipping) from childhood to early adulthood, and their dependence on ethnicity, gender and family history (FH) of essential hypertension (EH). Generalized estimating equations (GEEs) were used to estimate tracking coefficients for 295 European Americans and 252 African Americans, with a maximum of 12 measurements over a 15-year period. Office BP and ABP had moderate-to-relatively high tracking coefficients (r= 0.30–0.59; P≤0.001). Twenty-four hour readings tracked better than office readings for diastolic BP (DBP; 0.57 vs. 0.46, P=1.72×10−6) and pulse pressure (PP) (0.59 vs. 0.51, P=2.70×10−4), and equally well for systolic BP (SBP; 0.55 vs. 0.54, P=0.805). Daytime readings tracked better than their night-time counterparts for SBP (0.50 vs. 0.37, P=7.62×10−13), DBP (0.49 vs. 0.30, P=7.98×10−32) and PP (0.55 vs. 0.50, P=0.0061). All BPV (r=0.08–0.28; P≤0.001) and dipping measures (r=0.07–0.12; odds ratio, 1.60–1.73; P≤0.001) had low tracking coefficients. Males had significantly higher tracking stability for office SBP, DBP and ambulatory PP than females (P<0.01). Subjects with a positive FH of EH had significantly higher tracking stability for daytime and night-time DBP and dipping indexed by continuous variables than those with a negative FH (P<0.001). No significant ethnic differences were observed. The high tracking stability of 24-h ABP highlights the importance of using ambulatory BP monitoring in both research and clinical settings.

Keywords: ambulatory blood pressure, blood pressure variability, dipping, longitudinal study, tracking

INTRODUCTION

Tracking of a characteristic is defined as either the stability of a certain variable over time or the predictability of later values from earlier measurements.1,2 Longitudinal studies have shown significant office blood pressure (BP) tracking stability from childhood to adulthood,38 which is of considerable public health interest because children who are at high risk to develop adult hypertension might be identified at an early age. Although existing evidence suggests that ambulatory BP (ABP) is superior to office BP as a predictor of target-organ damage and cardiac morbidity and mortality,913 little is known about the long-term tracking ability of ABP, especially during the important transition period from childhood to early adulthood.

A non-invasive ABP monitor makes it possible to measure not only the ABP mean value, but also BP variability (BPV), which is generally estimated by the s.d. of ABP measures over 24 h and the separate subperiods of daytime and night time. Recently, BPV has been increasingly used as a predictor of target-organ damage and cardiovascular events;9,1417 however, little is known about its stability over time.

A nocturnal BP drop is another interesting feature revealed by ABP. A large number of studies have reported that individuals with a blunted nocturnal decline in BP, referred to as non-dippers, display the highest risk of target-organ damage and cardiovascular disease morbidity,18,19 because this pattern exposes these individuals to a greater cardiovascular load each day. Limited evidence is available on the reproducibility of the nocturnal BP drop. The evidence is conflicting: some studies show no reproducibility,2024 whereas others indicate relatively good reproducibility.2528 It should be noted that, in all of the available evidence, the nocturnal BP drop was studied across only two visits within a short period of follow-up, so evidence regarding tracking of the nocturnal BP drop from multiple visits with a longer period of follow-up is needed.

In this study of 295 European American (EA) and 252 African American (AA) youths evaluated up to 12 times over a 15-year period from childhood to early adulthood, we examined and contrasted the tracking ability of office BP and ABP, as well as the tracking stability of BPV and the nocturnal BP drop. We further determined the extent to which these tracking stabilities may depend on gender, ethnicity and family history (FH) of essential hypertension (EH).

METHODS

Study population

Subjects were selected from participants (n=745) in an ongoing longitudinal study evaluating the development of cardiovascular risk factors in youth.29,30 The data encompass a 15-year period (1989–2004) in which 12 assessments were conducted. The data set is complicated because not all subjects had the same number of visits; subjects were recruited into the study at different ages and in different years. Of the 745 subjects, 547 participants were included in this study based on the following criteria: (1) valid readings for both office and ABP and (2) at least two visits during the 15-year period. No significant difference in either office BP or ABP was found between individuals who qualified for this study and those who were excluded. The median age at the first visit was 14.1 years (range: 7.4–27.4; 25–75%: 12.2–16.2), and the median age at the last visit was 20.1 years (range: 11.4–29.5; 25–75%: 18.4–22.1). The median follow-up period was 5.8 years (range: 0.8–18; 25–75%: 3.6–7.9). The number of subjects with different numbers of office and ABP assessments is shown in Supplementary Table 1. More than 60% of participants had ≥4 visits, making this data set very informative for the study of BP tracking over time.

Subject recruitment, evaluation, classification and attrition rate have been described earlier.29 Briefly, recruitment and evaluation of subjects began in 1989. Participants who met the following criteria were recruited: (1) 7–16 years old in 1989; (2) AAs or EAs; (3) normotensive for age and gender based on BP screening; and (4) apparently healthy based on parental reports of medical history. The annualized attrition rate was <4% per year. There were no significant differences in age, ethnicity or gender distribution between dropouts and the subjects who remained in the study. A positive FH of EH was defined as the occurrence of EH in one or both biological parents at any visit. The diagnosis of EH was verified by the physician or medical records.29 Eleven subjects began to take antihypertensive medication during the study, and the data obtained during this period were excluded from analyses. The Institutional Review Board at the Medical College of Georgia gave approval for the study, and informed consent was obtained from one of the parents and from the child.

Measurements

Office BP recordings

At each annual laboratory visit during the 15-year period, both anthropometric and cardiovascular evaluations were conducted.29,31,32 Subjects’ height and weight were measured with a Healthometer medical scale that was calibrated daily. Body mass index (BMI) was calculated as a measure of general obesity. Office systolic BP (SBP) and diastolic BP (DBP) were measured with the Dinamap Vital Signs Monitor (model 1864 SX; Criticon Incorporated, Tampa, FL, USA). Cuff size was selected according to mid-arm circumference (12–19, 17–25, 23–33, 31–40 and 38–50 cm). BP measurements were taken at the 11th, 13th and 15th minutes of a 15-min supine relaxation period. The average of the last two readings was used to represent SBP and DBP values. Pulse pressure (PP) was defined as the difference between SBP and DBP (SBP—DBP).

Ambulatory BP recordings

Our procedures for ABP recordings have been described earlier in detail.30,33 Briefly, an ABP monitor was fitted to the non-dominant arm (model 90207, SpaceLabs, Redmond, WA, USA). Cuff size was selected according to mid-arm circumference (12–20, 17–26, 24–32, 32–42 and 38–50 cm). Measures were obtained every 20 min during the day (0800–2200 hours) and every 30 min at night (2400–0600 hours). Transitional periods from 0600 to 0800 hours and from 2200 hours to midnight were not included in the analyses. Adequacy of the recordings was based on acceptable readings using previously established criteria33 for ≥14 readings over the 14 h designated as daytime and ≥6 readings over the 6 h designated as the night time, as suggested by the European Society of Hypertension Working Group on Blood Pressure Monitoring.34 Mean values of SBP, DBP and PP for 24-h daytime and night-time subperiods were used as indices of ABP recordings.

BP variability

BP variability was indexed by the s.d. of the ABP recordings over the entire 24-h period and separately for daytime and night-time subperiods. In addition, to account for the influence of the nocturnal BP fall on the 24-h BP s.d., and to quantify 24-h BPV without the circadian component, the weighted 24-h BP s.d. was also used in this study, which is the mean of the daytime and night-time s.d. weighted for the duration of the daytime and night-time subperiods.35

Nocturnal BP fall (dipping)

Three indices of the nocturnal BP drop were used in this study. First, the difference between daytime and night time was evaluated. Second, the night-time BP drop expressed as a proportion of the daytime value was evaluated ((daytime—night time)/daytime). Third, subjects were classified into two categories: those whose night-time BP fell more than 10% of the daytime values (dippers) and those in whom it fell less (non-dippers).12

Statistical analyses

Tracking coefficients were estimated using the following multivariate linear regression model.

Yit=β0+β1Yit1+β2t+j=1jβ3jXijt+k=1kβ4kZik+εit

Yit is the dependent variable (which, in our study, may be office BP, ABP, BPV or dipping) for individual i from t2 to tm (where m is the number of measurements). Yit1 is the initial observation of individual i at t1 (t=time). Xijt is the time-dependent covariate j for individual i. Zik is the time-independent covariate k for subject i. εit is the measurement error for individual i.

In this model, the initial measurement of the dependent variable Y at time t1 (for example, office SBP reading on the first visit) is regressed on the same variable Y from time t2 to tm. β1 is the standardized regression coefficient of the initial measurement of the dependent variable, which can be interpreted as the average tracking coefficient across the duration of the study.36 A logistic regression model can be used to quantify tracking of a dichotomous variable (for example, dipper vs. non-dippers). In this case, the coefficient β1 can be transformed into an odds ratio, which gives the magnitude of the ‘odds’ of a subject belonging to a group at t1, with regard to the development of the subject’s group status from t2 to tm relative to the ‘odds’ of a subject not belonging to that group at t136.

This model has several advantages compared with other tracking models. First, it can handle missing values of the dependent variable, so a balanced data set is not required. Second, the use of covariates allowed us to adjust for possible confounders. In the present analysis, ethnicity, gender, FH of EH, age of the subjects’ initial visit and age of the subjects at follow-up visits were included as covariates.

To contrast tracking ability between office BP and 24-h BP or between daytime and night-time BP, we calculated the test statistic Z=(β1β2)(s.e.1×β1)2+(s.e.2×β2)2 which approximately follows a standard normal distribution, where β1 and β2 are standardized regression coefficients for different BP measurements, and s.e.1 and s.e.2 are s.e. for β1 and β2, respectively.37 A Bonferroni correction for multiple comparisons (n=6) was applied, and a value of P<0.008 was deemed statistically significant for this comparison.

For the tracking of BPV, mean ABP values were also included as a covariate. To investigate whether there was a significant effect of ethnicity, gender or FH of EH on tracking stability, the interaction terms among ethnicity, gender, FH of EH and Yit1 were tested. In an alternative model, BMI, height, weight and heart rate were further added to the model separately. To control for dependence between repeated observations in the same subjects, we used generalized estimating equations (GEEs), which yield unbiased s.e. and P-values.36 For the dichotomous variable of nocturnal BP drop, a GEE analysis for dichotomous outcome variables was used.36 All analyses were performed using STATA 8.0 (StataCorp, College Station, TX, USA).

RESULTS

The baseline (first visit) characteristics of demographics, office BP, ABP, BPV and dipping by ethnicity and gender are shown in Table 1. For the mean values of office BP and ABP, males had higher SBP and PP than females, whereas AAs had higher SBP and DBP than EAs. For BPV, males had higher levels in both SBP and DBP during 24 -h, daytime and weighted 24-h periods, whereas AAs had higher values of DBP during daytime, night-time, and weighted 24-h periods. For the nocturnal BP drop, EAs had a higher prevalence of dippers than AAs.

Table 1.

Characteristics of subjects’ first visit by ethnicity and gender

EA
AA
P-value
Males Females Males Females Gender Ethnicity
Demographics
n 156 139 107 145
 Age, years 14.2±3.1 14.4±3.1 14.2±3.0 14.4±3.2 NS NS
 Family history of EH, % 65.4 64.5 84.1 88.7 NS <0.001
 Subjects with ≥4 visits, % 60.3 64.0 72.0 71.7 NS <0.05
Anthropometrics
 Height, cm 162.8±16.3 158.1±11.2 162.2±14.1 159.2±10.9 <0.001 NS
 Weight, kg 58.5±19.3 56.6±17.4 61.2±22.1 63.5±22.4 NS <0.01
 BMI, kg/m2 21.4±4.5 22.3±5.3 22.6±5.6 24.7±7.3 <0.01 <0.001
Office BP, mmHg
 SBP 109.3±9.5 104.9±8.1 112.5±11.0 108.3±9.6 <0.001 0.001
 DBP 56.9±5.7 58.3±6.0 59.8±6.5 60.0±6.3 NS <0.001
 PP 52.4±9.3 46.6±7.0 52.7±10.0 48.4±8.6 <0.001 NS
ABP, mmHg
 24-h SBP 115.1±7.7 111.3±6.6 117.7±9.0 113.6±7.1 <0.001 <0.001
 24-h DBP 66.2±4.6 65.9±5.0 68.1±5.9 68.0±5.2 NS <0.001
 24-h PP 48.9±6.8 45.5±4.5 49.6±7.3 45.6±5.3 <0.001 NS
 Daytime SBP 119.4±8.5 115.5±7.4 121.4±9.6 117.2±7.9 <0.001 <0.05
 Daytime DBP 70.8±5.9 70.6±6.4 72.5±7.0 72.1±6.1 NS <0.01
 Daytime PP 48.6±7.0 44.9±4.4 48.9±7.6 45.1±5.5 <0.001 NS
 Night-time SBP 107.4±8.9 104.1±8.0 110.8±9.9 106.8±8.1 <0.001 0.001
 Night-time DBP 57.9±6.8 57.7±5.8 60.2±6.9 60.3±7.0 NS <0.001
 Night-time PP 49.5±7.6 46.4±5.4 50.7±8.2 46.4±6.1 <0.001 NS
BPV, mmHg
 24-h SBP s.d. 11.5±2.3 10.7±2.0 10.8±2.0 10.6±2.1 <0.01 <0.05
 24-h DBP s.d. 11.5±1.8 10.8±2.0 11.5±2.2 11.3±2.1 <0.01 NS
 Daytime SBP s.d. 9.9±2.4 9.3±2.1 9.5±2.1 9.3±2.0 <0.05 NS
 Daytime DBP s.d. 9.7±2.1 9.0±2.0 10.2±2.4 9.8±2.3 <0.01 0.001
 Night-time SBP s.d. 8.0±3.0 7.5±2.7 8.4±2.7 8.1±2.7 NS <0.05
 Night-time DBP s.d. 7.8±2.8 7.1±2.6 8.2±3.0 8.2±3.0 NS 0.001
 Weighted 24-h SBP s.d. 9.3±2.1 8.7±1.6 9.2±1.8 9.0±1.7 <0.01 NS
 Weighted 24-h DBP s.d. 9.1±1.8 8.4±1.7 9.5±2.0 9.3±2.0 <0.01 <0.001
Dipping
 Day–night SBP, mmHg 12.1±8.3 11.4±7.6 10.6±7.8 10.4±7.8 NS NS
 Day–night DBP, mmHg 13.0±8.4 12.9±6.9 12.3±7.5 11.8±8.1 NS NS
 (Day–night)/day SBP, % 9.9 9.7 8.6 8.7 NS NS
 (Day–night)/day DBP, % 17.8 17.8 16.6 16.0 NS NS
 Dipper for SBP, % 57.1 54.0 44.9 43.4 NS <0.01
 Dipper for DBP, % 84.0 85.6 77.6 76.6 NS <0.05

Abbreviations: AA, African American; ABP, ambulatory blood pressure; BMI, body mass index; BPV, blood pressure variability; DBP, diastolic blood pressure; EA, European American; EH, essential hypertension; NS, not significant; PP, pulse pressure; SBP, systolic blood pressure.

Values are mean ±s.d.

After adjustment for age, gender, ethnicity and FH of EH (with additional adjustment for mean ABP values for BPV measures), the tracking coefficients and their 95% confidence intervals (CIs) for office BP, ABP, BPV and dipping are shown in Table 2. The tracking coefficients of office BP and ABP measures ranged from 0.30–0.59 (P≤0.001), which indicated moderate-to-relatively high stability of tracking. In all, 24-h readings tracked better than office readings for DBP (0.57 vs. 0.46, P=1.72×10−6) and PP (0.59 vs. 0.51, P=2.70×10−4), whereas they tracked equally well for SBP (0.55 vs. 0.54, P=0.805). Daytime readings tracked better than their night-time counterparts for SBP (0.50 vs. 0.37, P=7.62×10−13), DBP (0.49 vs. 0.30, P=7.98×10−32) and PP (0.55 vs. 0.50, P=0.0061). Additional adjustments for other potential confounders (BMI, height, weight and heart rate separately) did not change the results (data not shown).

Table 2.

Tracking coefficients of office BP, ABP, BPV and nocturnal BP fall (dipping) in all subjects

SBP
Tracking coefficient (95% CI)
DBP
Tracking coefficient (95% CI)
PP
Tracking coefficient (95% CI)
Office BPa 0.54 (0.49, 0.60) 0.46 (0.41, 0.51) 0.51 (0.46, 0.56)
ABP a
 24 h 0.55 (0.50, 0.60) 0.57 (0.51, 0.62) 0.59 (0.53, 0.64)
 Daytime 0.50 (0.45, 0.55) 0.49 (0.44, 0.55) 0.55 (0.50, 0.60)
 Night time 0.37 (0.31, 0.42) 0.30 (0.23, 0.36) 0.50 (0.44, 0.55)
BPV b
 24-h s.d. 0.20 (0.14, 0.25) 0.28 (0.22, 0.33)
 Daytime s.d. 0.08 (0.02, 0.13) 0.21 (0.15, 0.26)
 Night-time s.d. 0.08 (0.03, 0.13) 0.11 (0.06, 0.16)
 Weighted 24-h s.d. 0.09 (0.04, 0.15) 0.21 (0.16, 0.27)
Dipping a
 1. Day–night 0.12 (0.07, 0.18) 0.09 (0.04, 0.15)
 2. (Day–night)/day 0.11 (0.06, 0.17) 0.07 (0.02, 0.12)
 3. Dipper vs. non-dipperc 1.73 (1.39, 2.16) 1.60 (1.17, 2.18)

Abbreviations: ABP, ambulatory blood pressure; BPV, blood pressure variability; DBP, diastolic blood pressure; PP, pulse pressure; SBP, systolic blood pressure.

P-value for tracking coefficients is ≤0.001.Tracking coefficient is the standardized regression coefficient for continuous variables.

a

All the tracking coefficients were adjusted for age, gender, ethnicity and family history of essential hypertension.

b

All the tracking coefficients were adjusted for age, gender, ethnicity, family history of essential hypertension and mean BP.

c

Odds ratio for dichotomous dipping (dipper: those whose night-time BP drop is >10% of the daytime values; non-dipper: those whose night-time BP drop is <10% of the daytime values).

Tracking coefficients for all measures of BPV were lower than 0.30 (range: 0.08–0.28, P≤0.001), indicating that BPV was not very stable over time.

For the nocturnal BP drop, both the absolute value of the difference between daytime and night time, and the night-time drop expressed as a proportion of the daytime BP had low tracking coefficients (range: 0.07–0.12). When subjects were classified as dippers vs. non-dippers, the tracking stability indexed by the odds ratio (range: 1.60–1.73) was also quite low. These results indicated that nocturnal BP drop was not stable over time, regardless of the index used.

Males had significantly higher tracking stability of office SBP, office DBP and ambulatory PP, but lower tracking stability on weighted 24-h s.d. of SBP than females (Table 3, Ps<0.01). Subjects with a positive FH of EH had significantly higher tracking of daytime and night-time DBP as well as the nocturnal BP drop in comparison with subjects with a negative FH (Table 4, Ps≤0.001). No significant ethnic differences in tracking stability of office BP, ABP, BPV and dipping were found (data not shown).

Table 3.

Tracking coefficients of office BP, ABP and BPV by gender

Male
Female
Tracking coefficient (95% CI) P-value Tracking coefficient (95% CI) P-value
Office BP a
 SBP 0.62 (0.54, 0.70) <0.001 0.51 (0.43, 0.59) <0.001
 DBP 0.50 (0.42, 0.57) <0.001 0.44 (0.36, 0.51) <0.001
ABP a
 24-h PP 0.73 (0.64, 0.83) <0.001 0.64 (0.57, 0.71) <0.001
 Daytime PP 0.69 (0.60, 0.79) <0.001 0.58 (0.51, 0.66) <0.001
 Night-time PP 0.58 (0.49, 0.67) <0.001 0.54 (0.46, 0.62) <0.001
BPV b
 Weighted 24-h SBP s.d. 0.05 (−0.03, 0.13) NS 0.14 (0.06, 0.21) <0.001

Abbreviations: ABP, ambulatory blood pressure; BPV, blood pressure variability; DBP, diastolic blood pressure; PP, pulse pressure; SBP indicates systolic blood pressure.

Tracking coefficient is the standardized regression coefficient.

a

All the tracking coefficients were adjusted for age, ethnicity and family history of essential hypertension.

b

All the tracking coefficients were adjusted for age, ethnicity, 24-h mean SBP and family history of essential hypertension.

Table 4.

Tracking coefficients of ABP and dipping by family history of essential hypertension

Negative on family history of EH
Positive on family history of EH
Tracking coefficient (95% CI) P-value Tracking coefficient (95% CI) P-value
ABP a
 Daytime DBP 0.40 (0.28, 0.53) <0.001 0.52 (0.46, 0.58) <0.001
 Night-time DBP 0.18 (0.06, 0.30) <0.01 0.32 (0.26, 0.38) <0.001
Dipping a
 SBP (day–night) 0.03 (−0.09, 0.15) NS 0.16 (0.11, 0.22) <0.001
 DBP (day–night) 0.02 (−0.10, 0.14) NS 0.12 (0.06, 0.18) <0.001
 SBP ((day–night)/day) 0.01 (−0.10, 0.13) NS 0.16 (0.10, 0.21) <0.001
 DBP ((day–night)/day) −0.01 (−0.12, 0.10) NS 0.10 (0.04, 0.16) 0.001

Abbreviations: ABP, ambulatory blood pressure; DBP, diastolic blood pressure; EH, essential hypertension; NS, not significant; SBP, systolic blood pressure.

Tracking coefficient is the standardized regression coefficient.

a

All the tracking coefficients were adjusted for age, gender and ethnicity.

DISCUSSION

Consistent with most of the earlier studies that have shown significant tracking of office BP from childhood to adulthood, we found moderate-to-relatively high tracking stability for office BP in this study. Little is known about the long-term tracking stability of ABP, especially during the important transition period from childhood to early adulthood. Lurbe et al.38 found good reproducibility of ABP monitoring in 30 healthy normotensive children. O’Sullivan et al.39 found high correlation coefficients for 24-h SBP (0.79) and DBP (0.55) in a study of 50 teenagers in whom ABP measurements were repeated 1 year later. On the basis of a 5-year follow-up of ABP in 162 healthy older adults, Goldstein et al.40 also found relatively high correlation coefficients for ABP (range: 0.62–0.70). It should be noted, however, that in these studies that suggest high tracking of ABP, only ABP at the first and the last visits within relatively short periods of follow-up was measured.3840 In this study with up to 12 repeated measurements over a 15-year period from childhood to early adulthood, we found moderate-to-relatively high tracking stability for all of the ABP measurements. The only earlier study comparing the tracking stability of ABP with that of office BP showed that 24-h ABP tracked better than office BP.39 We also found that 24-h ABP generally tracked better than office BP, although office SBP and 24-h SBP tracked equally well. Together with the evidence that ABP is a better predictor of organ damage, cardiovascular morbidity and mortality than office BP,913,41 our results highlight the importance of the use of ABP monitoring in clinical practice and the entire 24-h BP monitoring period in predicting future BP.

Evidence regarding BPV tracking stability over a long time period is lacking. In this study, we found that BPV had much lower tracking coefficients in comparison with ABP and office BP. Existing evidence indicates that the predictability/reproducibility of BPV is also low during a short time period,40,42,43 which is consistent with our results on the low tracking stability of BPV during a long time period. Some studies have suggested that the underlying reason for the low reproducibility of BPV may be frequent behavior changes and the responsiveness of BP to ‘external demands and internal homeostatic requirements’.44 Another possible reason for the low tracking stability of BPV is that BPV is strongly affected by outliers of ABP recordings; however, there is still no gold standard for the ABP editing procedure.34 Therefore, more objective criteria to identify a universally accepted editing procedure for ABP recordings and more suitable methods to properly assess BPV are warranted.

Existing evidence on the tracking stability of the nocturnal BP drop is conflicting; some studies show no reproducibility,2024 whereas others studies have indicate relatively good reproducibility.2528 On the basis of an investigation of 18 normotensive and 3 unmedicated hypertensive young adults, Dimsdale and Heeren20 found no reproducibility of nocturnal BP dipping indexed by the decrease in BP from daytime to night-time levels. In this study, consistent with the study of Dimsdale and Heeren,20 we found that the tracking coefficients were quite low (range: 0.07–0.13) for both the absolute difference between daytime and night time, and the night-time BP drop expressed as a proportion of the daytime values. With regard to dichotomous dipping (dipper vs. non-dipper), we found that the odds ratios were also quite low, which indicated that the nocturnal BP drop was not stable over time in youth and young adults, regardless of the index of dipping used.

In earlier studies concerning gender differences in office BP tracking, neither the Tromso Study5 nor the Amsterdam Growth and Health Study45 found any major differences. In this study, we found that males tracked better than females not only for office BP but also for ambulatory PP. The underlying reason for different tracking in males and females from childhood to adulthood in this study is not fully understood. One possible reason is that BP for females in adolescence or early adulthood is more likely to be influenced by their pubertal circadian activities (for example, menses) resulting in relatively poorer tracking stability than in males.

Although a positive FH of EH has been shown to predict higher BP levels in childhood and hypertension in later life,46 most of the earlier studies on tracking of BP failed to adjust for FH of EH as a potential confounder. To the best of our knowledge, we are the first to test potential differences on the basis of FH of EH in tracking ABP and the nocturnal BP drop. We found that individuals who had positive FHs of EH had significantly higher tracking stability of daytime and night-time DBP and all measures of the nocturnal BP drop than those who did not. The potential mechanisms behind this intriguing finding await further clarification.

The existing evidence on ethnic differences in BP tracking from childhood to early adulthood is scarce. Bao et al.47 showed similar tracking of BP in EAs and AAs from childhood to early adulthood, with correlation coefficients ranging from 0.36 to 0.50. In this study, consistent with the study of Bao et al.47, we did not find significant ethnic differences in the tracking of office BP, and this lack of ethnic differences in tracking was further extended to ABP, BPV and the nocturnal BP drop.

There are four limitations to this study. First, the pubertal maturation stage may have an effect on the tracking stability of BP, BPV and dipping. According to Daniels et al.48 the effect of sexual maturation on BP was dependent on body size. As we addressed the effects of height and BMI in our study, which did not change the tracking coefficients of BP, BPV and dipping, we have at least partly controlled for sexual maturation. Second, the use of Dinamap to measure office BP has been criticized.49 This should not have had any influence on the tracking stability of office BP because the same device was used throughout the study. Moreover, in a recent meta-analysis by Chen et al.,50 an automated BP device was equally good or even better than other devices at predicting long-term DBP tracking from childhood to adulthood. Third, BPV indices in this study represented 20 (daytime)/30 min (night time) intermittent BPV, but not beat-to-beat BPV. Although a study by di Rienzo et al.51 showed that BPV obtained by intermittent measurements was not significantly different from that obtained by beat-to-beat measurements when the time period between the intermittent measurements of ABP ranged from 5 to 20 min, future studies on BPV using beat-to-beat BP measurement are warranted. Fourth, the method used to calculate tracking coefficients in this study differs from that used by others (for example, correlation coefficients). Thus, we should be cautious in generalizing of the magnitude of the tracking coefficients in this study in comparison with those assessed using different methods.

In this study, we observed that office BP and ABP had moderate-to-relatively high tracking stability from childhood to early adulthood. The better tracking stability of 24-h ABP in comparison with office BP established by this study does not suggest that 24-h ABP will be able to identify children who will definitely develop hypertension in their adult life. In combination with the better predictive values of end-organ damage and cardiovascular events of 24-h ABP, however, it does indicate the use of 24-h ABP monitoring in future cardiovascular risk assessment and daily clinical practice. Furthermore, the better tracking stability of 24-h ABP monitoring will increase the acceptance of ABP monitoring as a useful modality for the evaluation of BP levels in children and adolescents. Although BPV and nocturnal dipping have been widely used to predict target-organ damage and cardiovascular events, this study suggests that neither of these measures shows stability over time. This should be emphasized in longitudinal studies using these two measures to predict the development of target-organ damage and cardiovascular outcomes, especially in studies involving pediatric populations.

Supplementary Material

supplemenatry data

ACKNOWLEDGEMENTS

This study was supported by the following Grants: (1) HL086530 and HL69999 from the National Heart, Lung and Blood Institute; (2) 0730156N from the American Heart Association.

Footnotes

CONFLICT OF INTEREST The authors declare no conflict of interest.

Supplementary Information accompanies the paper on Hypertension Research website (http://www.nature.com/hr)

References

  • 1.Ware JH, Wu MC. Tracking: prediction of future values from serial measurements. Biometrics. 1981;37:427–437. [Google Scholar]
  • 2.Foulkes MA, Davis CE. An index of tracking for longitudinal data. Biometrics. 1981;37:439–446. [Google Scholar]
  • 3.Elliott WJ. Blood pressure tracking. J Cardiovasc Risk. 1997;4:251–256. [PubMed] [Google Scholar]
  • 4.Fuentes RM, Notkola IL, Shemeikka S, Tuomilehto J, Nissinen A. Tracking of systolic blood pressure during childhood: a 15-year follow-up population-based family study in eastern Finland. J Hypertens. 2002;20:195–202. doi: 10.1097/00004872-200202000-00008. [DOI] [PubMed] [Google Scholar]
  • 5.Wilsgaard T, Jacobsen BK, Schirmer H, Thune I, Lochen ML, Njolstad I, Arnesen E. Tracking of cardiovascular risk factors: the Tromso study, 1979–1995. Am J Epidemiol. 2001;154:418–426. doi: 10.1093/aje/154.5.418. [DOI] [PubMed] [Google Scholar]
  • 6.Burke V, Beilin LJ, Dunbar D. Tracking of blood pressure in Australian children. J Hypertens. 2001;19:1185–1192. doi: 10.1097/00004872-200107000-00002. [DOI] [PubMed] [Google Scholar]
  • 7.Kelder SH, Osganian SK, Feldman HA, Webber LS, Parcel GS, Leupker RV, Wu MC, Nader PR. Tracking of physical and physiological risk variables among ethnic subgroups from third to eighth grade: the Child and Adolescent Trial for Cardiovascular Health cohort study. Prev Med. 2002;34:324–333. doi: 10.1006/pmed.2001.0990. [DOI] [PubMed] [Google Scholar]
  • 8.Woelk G. Blood pressure tracking from child to adulthood: a review. Cent Afr J Med. 1994;40:163–169. [PubMed] [Google Scholar]
  • 9.Parati G, Pomidossi G, Albini F, Malaspina D, Mancia G. Relationship of 24-h blood pressure mean and variability to severity of target-organ damage in hypertension. J Hypertens. 1987;5:93–98. doi: 10.1097/00004872-198702000-00013. [DOI] [PubMed] [Google Scholar]
  • 10.Appel LJ, Stason WB. Ambulatory blood pressure monitoring and blood pressure self-measurement in the diagnosis and management of hypertension. Ann Intern Med. 1993;118:867–882. doi: 10.7326/0003-4819-118-11-199306010-00008. [DOI] [PubMed] [Google Scholar]
  • 11.Verdecchia P, Porcellati C, Schillaci G, Borgioni C, Ciucci A, Battistelli M, Guerrieri M, Gatteschi C, Zampi I, Santucci A. Ambulatory blood pressure. An independent predictor of prognosis in essential hypertension. Hypertension. 1994;24:793–801. doi: 10.1161/01.hyp.24.6.793. [DOI] [PubMed] [Google Scholar]
  • 12.Mancia G, Parati G. Ambulatory blood pressure monitoring and organ damage. Hypertension. 2000;36:894–900. doi: 10.1161/01.hyp.36.5.894. [DOI] [PubMed] [Google Scholar]
  • 13.Dolan E, Stanton A, Thijs L, Hinedi K, Atkins N, McClory S, Den Hond E, McCormack P, Staessen JA, O’Brien E. Superiority of ambulatory over clinic blood pressure measurement in predicting mortality: the Dublin outcome study. Hypertension. 2005;46:156–161. doi: 10.1161/01.HYP.0000170138.56903.7a. [DOI] [PubMed] [Google Scholar]
  • 14.Palatini P, Penzo M, Racioppa A, Zugno E, Guzzardi G, Anaclerio M, Pessina AC. Clinical relevance of nighttime blood pressure and of daytime blood pressure variability. Arch Intern Med. 1992;152:1855–1860. [PubMed] [Google Scholar]
  • 15.Frattola A, Parati G, Cuspidi C, Albini F, Mancia G. Prognostic value of 24-h blood pressure variability. J Hypertens. 1993;11:1133–1137. doi: 10.1097/00004872-199310000-00019. [DOI] [PubMed] [Google Scholar]
  • 16.Verdecchia P, Angeli F, Gattobigio R, Rapicetta C, Reboldi G. Impact of blood pressure variability on cardiac and cerebrovascular complications in hypertension. Am J Hypertens. 2007;20:154–161. doi: 10.1016/j.amjhyper.2006.07.017. [DOI] [PubMed] [Google Scholar]
  • 17.Sander D, Kukla C, Klingelhofer J, Winbeck K, Conrad B. Relationship between circadian blood pressure patterns and progression of early carotid atherosclerosis: A 3-year follow-up study. Circulation. 2000;102:1536–1541. doi: 10.1161/01.cir.102.13.1536. [DOI] [PubMed] [Google Scholar]
  • 18.Verdecchia P, Schillaci G, Guerrieri M, Gatteschi C, Benemio G, Boldrini F, Porcellati C. Circadian blood pressure changes and left ventricular hypertrophy in essential hypertension. Circulation. 1990;81:528–536. doi: 10.1161/01.cir.81.2.528. [DOI] [PubMed] [Google Scholar]
  • 19.Verdecchia P, Schillaci G, Gatteschi C, Zampi I, Battistelli M, Bartoccini C, Porcellati C. Blunted nocturnal fall in blood pressure in hypertensive women with future cardiovascular morbid events. Circulation. 1993;88:986–992. doi: 10.1161/01.cir.88.3.986. [DOI] [PubMed] [Google Scholar]
  • 20.Dimsdale JE, Heeren MM. How reliable is nighttime blood pressure dipping? Am J Hypertens. 1998;11:606–609. doi: 10.1016/s0895-7061(98)00033-8. [DOI] [PubMed] [Google Scholar]
  • 21.Omboni S, Parati G, Palatini P, Vanasia A, Muiesan ML, Cuspidi C, Mancia G. Reproducibility and clinical value of nocturnal hypotension: prospective evidence from the SAMPLE study. Study on Ambulatory Monitoring of Pressure and Lisinopril Evaluation. J Hypertens. 1998;16:733–738. doi: 10.1097/00004872-199816060-00003. [DOI] [PubMed] [Google Scholar]
  • 22.Mochizuki Y, Okutani M, Donfeng Y, Iwasaki H, Takusagawa M, Kohno I, Mochizuki S, Umetani K, Ishii H, Ijiri H, Komori S, Tamura K. Limited reproducibility of circadian variation in blood pressure dippers and nondippers. Am J Hypertens. 1998;11:403–409. doi: 10.1016/s0895-7061(97)00497-4. [DOI] [PubMed] [Google Scholar]
  • 23.Cuspidi C, Meani S, Salerno M, Valerio C, Fusi V, Severgnini B, Lonati L, Magrini F, Zanchetti A. Reproducibility of nocturnal blood pressure fall in early phases of untreated essential hypertension: a prospective observational study. J Hum Hypertens. 2004;18:503–509. doi: 10.1038/sj.jhh.1001681. [DOI] [PubMed] [Google Scholar]
  • 24.Cuspidi C, Meani S, Valerio C, Sala C, Fusi V, Masaidi M, Zanchetti A, Mancia G. Reproducibility of dipping/nondipping pattern in untreated essential hypertensive patients: impact of sex and age. Blood Press Monit. 2007;12:101–106. doi: 10.1097/MBP.0b013e32809efa51. [DOI] [PubMed] [Google Scholar]
  • 25.Kario K, Shimada K. Differential effects of amlodipine on ambulatory blood pressure in elderly hypertensive patients with different nocturnal reductions in blood pressure. Am J Hypertens. 1997;10:261–268. doi: 10.1016/s0895-7061(96)00409-8. [DOI] [PubMed] [Google Scholar]
  • 26.Dimsdale JE, von Kanel R, Profant J, Nelesen R, Ancoli-Israel S, Ziegler M. Reliability of nocturnal blood pressure dipping. Blood Press Monit. 2000;5:217–221. doi: 10.1097/00126097-200008000-00004. [DOI] [PubMed] [Google Scholar]
  • 27.Rahman M, Griffin V, Heyka R, Hoit B. Diurnal variation of blood pressure; reproducibility and association with left ventricular hypertrophy in hemodialysis patients. Blood Press Monit. 2005;10:25–32. doi: 10.1097/00126097-200502000-00006. [DOI] [PubMed] [Google Scholar]
  • 28.Stenehjem AE, Os I. Reproducibility of blood pressure variability, white-coat effect and dipping pattern in untreated, uncomplicated and newly diagnosed essential hypertension. Blood Press. 2004;13:214–224. doi: 10.1080/08037050410021432. [DOI] [PubMed] [Google Scholar]
  • 29.Dekkers JC, Snieder H, Van Den Oord EJ, Treiber FA. Moderators of blood pressure development from childhood to adulthood: a 10-year longitudinal study. J Pediatr. 2002;141:770–779. doi: 10.1067/mpd.2002.128113. [DOI] [PubMed] [Google Scholar]
  • 30.Wang X, Poole JC, Treiber FA, Harshfield GA, Hanevold CD, Snieder H. Ethnic and gender differences in ambulatory blood pressure trajectories: results from a 15-year longitudinal study in youth and young adults. Circulation. 2006;114:2780–2787. doi: 10.1161/CIRCULATIONAHA.106.643940. [DOI] [PubMed] [Google Scholar]
  • 31.Barnes VA, Johnson MH, Dekkers JC, Treiber FA. Reproducibility of ambulatory blood pressure measures in African-American adolescents. Ethn Dis. 2002;12:S3-101–S3-106. [PMC free article] [PubMed] [Google Scholar]
  • 32.Dekkers JC, Treiber FA, Kapuku G, Snieder H. Differential influence of family history of hypertension and premature myocardial infarction on systolic blood pressure and left ventricular mass trajectories in youth. Pediatrics. 2003;111:1387–1393. doi: 10.1542/peds.111.6.1387. [DOI] [PubMed] [Google Scholar]
  • 33.Harshfield GA, Barbeau P, Richey PA, Alpert BS. Racial differences in the influence of body size on ambulatory blood pressure in youths. Blood Press Monit. 2000;5:59–63. [PubMed] [Google Scholar]
  • 34.O’Brien E, Asmar R, Beilin L, Imai Y, Mallion JM, Mancia G, Mengden T, Myers M, Padfield P, Palatini P, Parati G, Pickering T, Redon J, Staessen J, Stergiou G, Verdecchia P, European Society of Hypertension Working Group on Blood Pressure Monitoring European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J Hypertens. 2003;21:821–848. doi: 10.1097/00004872-200305000-00001. [DOI] [PubMed] [Google Scholar]
  • 35.Parati G, Bilo G, Vettorello M, Groppelli A, Maronati A, Tortorici E, Caldara G, Mancia G. Assessment of overall blood pressure variability and its different components. Blood Press Monit. 2003;8:155–159. doi: 10.1097/00126097-200308000-00005. [DOI] [PubMed] [Google Scholar]
  • 36.Twisk WR. Applied Longitudinal Data Analysis For Epidemiology—A Practical Guide. Cambridge University Press; United Kingdom: 2003. [Google Scholar]
  • 37.Wang Y, Wang X. Re: ‘Tracking of cardiovascular risk factors: the Tromsø Study, 1979–1995’. Am J Epidemiol. 2002;155:1144–1145. doi: 10.1093/aje/155.12.1144. [DOI] [PubMed] [Google Scholar]
  • 38.Lurbe E, Aguilar F, Gomez A, Tacons J, Alvarez V, Redon J. Reproducibility of ambulatory blood pressure monitoring in children. J Hypertens Suppl. 1993;11:S288–S289. [PubMed] [Google Scholar]
  • 39.O’Sullivan JJ, Derrick G, Foxall RJ. Tracking of 24-h and casual blood pressure: a 1-year follow-up study in adolescents. J Hypertens. 2000;18:1193–1196. doi: 10.1097/00004872-200018090-00004. [DOI] [PubMed] [Google Scholar]
  • 40.Goldstein IB, Shapiro D, Guthrie D. A 5-year follow-up of ambulatory blood pressure in healthy older adults. Am J Hypertens. 2003;16:640–645. doi: 10.1016/s0895-7061(03)00906-3. [DOI] [PubMed] [Google Scholar]
  • 41.Sega R, Facchetti R, Bombelli M, Cesana G, Corrao G, Grassi G, Mancia G. Prognostic value of ambulatory and home blood pressures compared with office blood pressure in the general population: follow-up results from the Pressioni Arteriose Monitorate e Loro Associazioni (PAMELA) study. Circulation. 2005;111:1777–1783. doi: 10.1161/01.CIR.0000160923.04524.5B. [DOI] [PubMed] [Google Scholar]
  • 42.Gerin W, Rosofsky M, Pieper C, Pickering TG. A test of reproducibility of blood pressure and heart rate variability using a controlled ambulatory procedure. J Hypertens. 1993;11:1127–1131. doi: 10.1097/00004872-199310000-00018. [DOI] [PubMed] [Google Scholar]
  • 43.Palatini P, Mormino P, Canali C, Santonastaso M, de Venuto G, Zanata G, Pessina AC. Factors affecting ambulatory blood pressure reproducibility. Results of the HARVEST trial. Hypertension and Ambulatory Recording Venetia Study. Hypertension. 1994;23:211–216. doi: 10.1161/01.hyp.23.2.211. [DOI] [PubMed] [Google Scholar]
  • 44.Ward MMTJ, Johnston DW. Temporal stability of ambulatory cardiovascular monitoring. Ann Behav Med. 1994;16:12–23. [Google Scholar]
  • 45.Twisk JW, Kemper HC, van Mechelen W, Post GB. Tracking of risk factors for coronary heart disease over a 14-year period: a comparison between lifestyle and biologic risk factors with data from the Amsterdam Growth and Health Study. Am J Epidemiol. 1997;145:888–898. doi: 10.1093/oxfordjournals.aje.a009048. [DOI] [PubMed] [Google Scholar]
  • 46.Munger RG, Prineas RJ, Gomez-Marin O. Persistent elevation of blood pressure among children with a family history of hypertension: the Minneapolis Children’s Blood Pressure Study. J Hypertens. 1988;6:647–653. doi: 10.1097/00004872-198808000-00008. [DOI] [PubMed] [Google Scholar]
  • 47.Bao W, Threefoot SA, Srinivasan SR, Berenson GS. Essential hypertension predicted by tracking of elevated blood pressure from childhood to adulthood: the Bogalusa Heart Study. Am J Hypertens. 1995;8:657–665. doi: 10.1016/0895-7061(95)00116-7. [DOI] [PubMed] [Google Scholar]
  • 48.Daniels SR, Obarzanek E, Barton BA, Kimm SY, Similo SL, Morrison JA. Sexual maturation and racial differences in blood pressure in girls: the National Heart, Lung, and Blood Institute Growth and Health Study. J Pediatr. 1996;129:208–213. doi: 10.1016/s0022-3476(96)70244-5. [DOI] [PubMed] [Google Scholar]
  • 49.O’Brien E, Waeber B, Parati G, Staessen J, Myers MG. Blood pressure measuring devices: recommendations of the European Society of Hypertension. BMJ. 2001;322:531–536. doi: 10.1136/bmj.322.7285.531. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50.Chen X, Wang Y, Appel LJ, Mi J. Impacts of measurement protocols on blood pressure tracking from childhood into adulthood: a meta regression analysis. Hypertension. 2008;51:642–649. doi: 10.1161/HYPERTENSIONAHA.107.102145. [DOI] [PubMed] [Google Scholar]
  • 51.di Rienzo M, Grassi G, Pedotti A, Mancia G. Continuous vs intermittent blood pressure measurements in estimating 24-h average blood pressure. Hypertension. 1983;5:264–269. doi: 10.1161/01.hyp.5.2.264. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

supplemenatry data

RESOURCES