Skip to main content
The Journal of Clinical Investigation logoLink to The Journal of Clinical Investigation
. 1977 Sep;60(3):611–619. doi: 10.1172/JCI108812

Circulating Immune Complexes after Renal Transplantation

CORRELATION OF INCREASED 125I-C1q BINDING ACTIVITY WITH ACUTE REJECTION CHARACTERIZED BY FIBRIN DEPOSITION IN THE KIDNEY

Yuet M Ooi 1,2,3, Boon S Ooi 1,2,3, Enrique H Vallota 1,2,3, Martin R First 1,2,3, Victor E Pollak 1,2,3
PMCID: PMC372405  PMID: 330564

Abstract

To assess the role of circulating immune complexes in the pathogenesis of acute rejection, sera were measured for such complexes by the 125I-C1q binding assay in 45 normal subjects, 24 allografted patients undergoing acute rejection, and in 11 allografted patients in a quiescent phase. Increased C1q-binding activity (C1q-BA) was detected in 14 patients with acute rejection, 9 of whom had renal biopsies showing fibrin deposition in the vasculature together with cellular infiltrates in the tubulo-interstitial structures; renal histology was not available in the other 5 patients. The other 10 patients with acute rejection, whose biopsies showed only cellular infiltrates, and the 11 patients in a quiescent phase posttransplantation did not have increased levels of serum C1q-BA.

Of the group with increased serum C1q-BA, serial studies in eight patients showed a correlation between increased serum C1q-BA and the occurrence of rejection; with reversal by therapy, serum C1q-BA returned to within normal levels. Complexes from six patients were analyzed by sucrose density gradient ultracentrifugation to have sedimentation coefficients ranging from 15S to 18.4S. After acid dissociation and analysis by double-diffusion techniques, C1q-reactive complexes were shown to contain IgG. Immunofluorescent studies done in five renal biopsies from this group revealed granular deposits of immunoglobulin, and (or) less frequently, of complement in the glomeruli or the tubular basement membranes.

The findings suggest that circulating immune complexes may mediate the type of acute rejection characterized by fibrin deposition in the kidney. The role of circulating immune complexes arising from the recipient's original kidney disease could be excluded in 10 patients with humoral rejection, inasmuch as the underlying renal pathology was of a “nonimmunologic” nature; this was corroborated by sequential studies in six patients in whom circulating immune complexes could not be demonstrated before rejection. The participation of administered antilymphocyte globulin (ALG) as an antigen also appears to be excluded in four patients, two who were not given ALG, and in two of whom episodes of rejection occurred unrelated temporally to ALG administration.

Full text

PDF
611

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Heusser C., Boesman M., Nordin J. H., Isliker H. Effect of chemical and enzymatic radioiodination on in vitro human Clq activities. J Immunol. 1973 Mar;110(3):820–828. [PubMed] [Google Scholar]
  2. LEE L. Antigen-antibody reaction in the pathogenesis of bilateral renal cortical necrosis. J Exp Med. 1963 Mar 1;117:365–376. doi: 10.1084/jem.117.3.365. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Levine P. H., Merrill D. A., Kohler P. F., Claman H. N. Changes in serum immunoglobulin and complement levels following renal homotransplantation. Transplantation. 1970 Aug;10(2):141–154. doi: 10.1097/00007890-197008000-00001. [DOI] [PubMed] [Google Scholar]
  4. MARSHALL J. D., EVELAND W. C., SMITH C. W. Superiority of fluorescein isothiocyanate (Riggs) for fluorescent-antibody technic with a modification of its application. Proc Soc Exp Biol Med. 1958 Aug-Sep;98(4):898–900. doi: 10.3181/00379727-98-24222. [DOI] [PubMed] [Google Scholar]
  5. McKenzie I. F., Whittingham S. Deposits of immunoglobulin and fibrin in human allografted kidneys. Lancet. 1968 Dec 21;2(7582):1313–1316. doi: 10.1016/s0140-6736(68)91815-1. [DOI] [PubMed] [Google Scholar]
  6. Nydegger U. E., Lambert P. H., Gerber H., Miescher P. A. Circulating immune complexes in the serum in systemic lupus erythematosus and in carriers of hepatitis B antigen. Quantitation by binding to radiolabeled C1q. J Clin Invest. 1974 Aug;54(2):297–309. doi: 10.1172/JCI107765. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Ooi B. S., Jao W., First M. R., Mancilla R., Pollak V. E. Acute interstitial nephritis. A clinical and pathologic study based on renal biopsies. Am J Med. 1975 Nov;59(5):614–628. doi: 10.1016/0002-9343(75)90223-5. [DOI] [PubMed] [Google Scholar]
  8. Ooi Y. M., Vallota E. H., West C. D. Classical complement pathway activation in membranoproliferative glomerulonephritis. Kidney Int. 1976 Jan;9(1):46–53. doi: 10.1038/ki.1976.6. [DOI] [PubMed] [Google Scholar]
  9. Ooi Y. M., Vallota E. H., West C. D. Serum immune complexes in membranoproliferative and other glomerulonephritides. Kidney Int. 1977 Apr;11(4):275–283. doi: 10.1038/ki.1977.41. [DOI] [PubMed] [Google Scholar]
  10. Palosuo T., Kano K., Anthone S., Gerbasi J. R., Milgrom F. Circulating immune complexes after kidney transplantation. Transplantation. 1976 Apr;21(4):312–316. doi: 10.1097/00007890-197604000-00007. [DOI] [PubMed] [Google Scholar]
  11. Porter K. A., Andres G. A., Calder M. W., Dossetor J. B., Hsu K. C., Rendall J. M., Seegal B. C., Starzl T. E. Human renal transplants. II. Immunofluorescent and immunoferritin studies. Lab Invest. 1968 Feb;18(2):159–171. [PubMed] [Google Scholar]
  12. Ratnoff O. D. Some relationships among hemostasis, fibrinolytic phenomena, immunity, and the inflammatory response. Adv Immunol. 1969;10:145–227. doi: 10.1016/s0065-2776(08)60417-4. [DOI] [PubMed] [Google Scholar]
  13. Rosenau W., Lee J. C., Najarian J. S. A light, fluorescence, and electron microscopic study of functioning human renal transplants. Surg Gynecol Obstet. 1969 Jan;128(1):62–76. [PubMed] [Google Scholar]
  14. Shehadeh I. H., Carpenter C. B., Monterio C. H., Merrill J. P. Renal allograft rejection. An analysis of lysozymuria, serum complement, lymphocyturia, and heterophil antibodies. Arch Intern Med. 1970 May;125(5):850–857. doi: 10.1001/archinte.125.5.850. [DOI] [PubMed] [Google Scholar]
  15. Yokoyama T., Torisu M., Durst A. L., Schroter G., Groth C. G., Starzl T. E. The complement system in renal homograft recipents. Surgery. 1972 Oct;72(4):611–618. [PMC free article] [PubMed] [Google Scholar]
  16. Yonemasu K., Stroud R. M. Clq: rapid purification method for preparation of monospecific antisera and for biochemical studies. J Immunol. 1971 Feb;106(2):304–313. [PubMed] [Google Scholar]
  17. Zubler R. H., Lange G., Lambert P. H., Miescher P. A. Detection of immune complexes in unheated sera by modified 125I-Clq binding test. Effect of heating on the binding of Clq by immune complexes and application of the test to systemic lupus erythematosus. J Immunol. 1976 Jan;116(1):232–235. [PubMed] [Google Scholar]
  18. Zubler R. H., Nydegger U., Perrin L. H., Fehr K., McCormick J., Lambert P. H., Miescher P. A. Circulating and intra-articular immune complexes in patients with rheumatoid arthritis. Correlation of 125I-Clq binding activity with clinical and biological features of the disease. J Clin Invest. 1976 May;57(5):1308–1319. doi: 10.1172/JCI108399. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Investigation are provided here courtesy of American Society for Clinical Investigation

RESOURCES