Skip to main content
Saudi Journal of Ophthalmology logoLink to Saudi Journal of Ophthalmology
. 2012 Jan 6;26(1):19–24. doi: 10.1016/j.sjopt.2011.10.004

Intraocular lens power calculation after myopic and hyperopic laser vision correction using optical coherence tomography

Maolong Tang a, Li Wang b, Douglas D Koch b, Yan Li a, David Huang a,
PMCID: PMC3729348  PMID: 23960964

Abstract

Purpose

To use optical coherence tomography (OCT) to measure corneal power and calculate intraocular lens (IOL) power in cataract surgeries after myopic and hyperopic laser vision correction (LVC).

Methods

Patients with previous LVC were enrolled in this prospective study at two centers (Doheny Eye Institute, Los Angeles, CA, USA and Cullen Eye Institute, Houston, TX, USA). Corneal power was measured with a Fourier-domain OCT system. The intravisit repeatability of OCT corneal power measurement was evaluated by the pooled standard deviation of repeat scans. Axial length, anterior chamber depth, and automated keratometry were measured with the IOLMaster. An OCT-based IOL formula was developed. The mean absolute error (MAE) of refractive prediction for OCT-based IOL formula was calculated. The results were compared with the MAE for Haigis-L formula.

Results

A total of 31 eyes of 24 subjects who had uncomplicated cataract surgery with monofocal IOL implantation were enrolled in the two sites. Twenty-two eyes of 16 subjects had previous myopic LVC that ranged from −12.46 D to −0.88 D. Nine eyes of 8 subjects had previous hyperopic LVC that ranged from 0.66 D to 5.52 D. The intravisit repeatability of OCT corneal power measurement was 0.24 D. For the myopic LVC group, the OCT formula had a MAE of 0.57 D compared to an MAE of 0.73 D for the Haigis-L formula (p = 0.19). For the hyperopic LVC group, the MAE for OCT and Haigis-L formula was 0.26 D and 0.54 D, respectively (p > 0.05).

Conclusions

Corneal power can be precisely measured with OCT. The predictive accuracy of OCT-based IOL power calculation is equal to current standards for post-LVC eyes.

Keywords: Intraocular lens, Lasik, PRK, Optical coherence tomography

Introduction

LASIK, PRK, and other laser vision correction (LVC) procedures are popular surgical options for the correction of myopia, astigmatism, and hyperopia. An unfortunate consequence of LVC is the difficulty in accurately calculating intraocular lens (IOL) power for cataract surgery.1,2 More and more people who had LVC will face this problem as they age and develop cataract.

Theoretic formulae, including SRK/T, Hoffer Q and Holladay I, work well on virgin eyes that have not had LVC procedures. The achieved refractions after cataract surgery are within 1.0 D of the target in a great majority of eyes.3–5 However, prior LVC introduces error in corneal power measurement which introduces error in IOL power calculation because conventional instruments for measuring corneal power such as the manual keratometer, automated keratometer, and Placido-ring topography measure only the anterior corneal power and extrapolate the posterior corneal power by assuming a fixed relation between anterior and posterior surface curvatures. This assumption is implicit in the use of a fixed keratometric index (1.3375) to convert anterior corneal curvature to a net (or total) corneal power value.6 The assumption does not hold in eyes after LVC, which alters the anterior curvature but leaves the posterior surface unchanged.7–9 Therefore, myopic LVC will lead to overestimation of corneal power by standard keratometry because the negative power of the posterior corneal surface is underestimated, which results in hyperopic refractive outcome after cataract surgery.10,11 Similarly, hyperopic LVC will lead to the underestimation of corneal power by standard keratometry and may lead to myopic outcome.12

Theoretically, the most accurate way to obtain true corneal power should be to measure the posterior surface as well as the anterior surface, in each individual eye. This was pointed out in an editorial in the special issue of the Journal of Cataract of Refractive Surgery featuring this subject:13

“Resolution of this problem will require a method for accurately measuring posterior corneal power or a technique for adjusting IOL power after implantation. Until then, surgeons are faced with performing multiple calculations to ‘guesstimate’ the correct IOL for patients who, by their original decision to have PRK or LASIK, have demonstrated that they have above-average refractive demands.”

Direct measurement of the posterior corneal power can be accomplished by several corneal tomography systems. Slit-scanning tomography (Orbscan II, Bausch & Lomb), rotating slit Scheimpflug-camera (Pentacam, Oculus GmbH, Wetzlar, Germany) and dual-Scheimpflug (Galilei, Ziemer Ophthalmic Systems AG, Port, Switzerland) systems have been used for this purpose.14–19 However, the axial (depth) resolutions of these slit-scanning devices (we use this term to include Scheimpflug variants) are between 50 and 100 microns due to the diffraction limit of optical focusing. The relatively poor resolution can lead to large errors in the delineation of the posterior corneal border in the presence of corneal haze or opacity, a problem that is well documented for the slit-scanning devices.20–23

Optical coherence tomography (OCT) can also measure both anterior and posterior corneal powers.24,25 The higher axial resolution of OCT (3–17 microns in commercial instruments) allows for the clear delineation of corneal boundaries even in the presence of opacities.20 With the recent advance from time-domain to Fourier-domain detection, the speed of OCT corneal mapping is now faster than slit-scanning devices. Based on these theoretic advantages, we believe OCT is a promising technology to be developed for measuring corneal power and for IOL power calculations.

Materials and methods

This prospective observational study was conducted at the Doheny Eye Institute, University of Southern California, Los Angeles, CA, USA; and Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. The study protocols were approved by the institutional review boards of the two universities. Written informed consents were obtained from all participants. The study adhered to the tenets of the Declaration of Helsinki.

To be included in the study, the participants must be scheduled for cataract surgery with a participating surgeon and have previous LVC. The allowed LVC techniques included LASIK, photorefractive keratectomy (PRK), and laser subepithelial keratomileusis (LASEK). The participants must not have any vision limiting eye disease other than cataract.

The preoperative measurements for IOL calculation were performed at either Doheny or Cullen. Only eyes that received a monofocal IOL were included. These IOL’s included Alcon Acrysof™ SN60AT, SA60AT, SN60WF; and AMO ZA9003, SN6AT3, and SN6AT4. Axial length (AL) and anterior chamber depth (ACD) were measured with a partial coherence interferometer (IOLMaster, Carl Zeiss Meditec Inc.). The IOLMaster also provided the standard automated keratometry. Manifest refraction was measured at the 1-month postoperative visit (at least 30 days after cataract surgery) by study technicians at Cullen or Doheny.

Corneal power measurement by optical coherence tomography

Fourier-domain OCT systems (RTVue, Optovue Inc.) were used to measure anterior, posterior, net corneal powers and central corneal thickness (CCT) at both Doheny and Cullen. The OCT systems were calibrated once a month using a ceramic ball with a radius of 7.9328 mm to maintain accurate curvature measurement. The cornea was scanned with a mapping pattern (Pachymetry + Power) that consisted of 6 mm lines on 8 evenly-spaced meridians within an acquisition period of 0.31 s. Each meridional line comprised of 1019 axial scans. The subject was instructed to gaze at an internal fixation target with the eye being imaged. The operator centered the scan on the pupil by observing the real-time video image of the anterior eye during the scan. The corneal power was calculated by automated software that was jointly developed by the authors (M.T. and Y.L.) and Optovue Inc.25 Three OCT scans were taken at the preoperative visit.

IOL power formulae

The OCT-based IOL power formula was previously described.26 It used an eye model consisting of four optical surfaces: anterior corneal surface, posterior corneal surface, IOL, and the retina. The IOL was modeled as a thin lens.

For eyes after myopic LVC, the OCT net corneal power was converted to an effective corneal power (ECP) before insertion into the IOL formula:

ECP=1.0208*net corneal power-1.6622 (1)

For eyes after hyperopic LVC, the OCT net corneal power was converted to an effective corneal power (ECP) before insertion into the IOL formula:

ECP=1.1*net corneal power-5.736 (2)

Eqs. (1) and (2) were based on linear regression of back-calculated ECP against OCT net corneal power. The back-calculated ECP was from the actual refractive outcome of all subjects. If both eyes of a subject were included in the study, only one eye was used to generate back-calculated ECP.

For comparison, we used the ASCRS IOL calculator (http://iol.ascrs.org) to obtain Haigis-L formula27 results. The mean absolute errors (MAEs) in predicting the postoperative manifest refraction spherical equivalent (MRSE) for each formula was calculated by:

MAE=|predicted-actual MRSE| (3)

Cataract surgery

Cataract surgery was performed by standard phacoemulsification through corneal tunnel incisions. The foldable IOLs were inserted and positioned in the capsular bag. The surgeons included coauthors DDK, DH, and others at Cullen and Doheny. The Doheny dataset included two cases performed by two referring surgeons outside the Doheny Eye Institute. Personalized IOL constants optimized for the surgeons were used at Cullen based on a broad range of previous IOL cases. The IOL constants in the standard IOL-Master database were used at Doheny.

Statistical analysis

The Wilcoxon signed-rank test (for paired samples) was used to compare the MAE between different OCT-based IOL formula and Haigis-L formula. The chi-square test was used to compare the proportion of eyes within 1 D of predicted refraction. A p-value of less than 0.05 is considered statistically significant. Repeatability was measured by the standard deviation (SD) of repeat measurements.

Results

Subject characteristics

A total of 31 eyes from 24 cataract surgery patients (13 women, 10 men) with previous LVC were enrolled at the two sites. The age was 58.1 ± 10.7 years (range 34–77 years) at the time of surgery. Twenty-two eyes of 16 subjects had previous myopic LVC with the average magnitude −4.97 ± 3.16 D and ranged from −12.46 D to −0.88 D. Nine eyes of eight subjects had previous hyperopic LVC with the average magnitude 2.32 ± 2.22 D and ranged from 0.66 D to 5.52 D.

Corneal power measurements

The intravisit repeatabilities of OCT corneal power measurements were 0.25, 0.04, and 0.24 D anterior, posterior, and net corneal power, respectively.

For the myopic LVC group, the net corneal power measured by Fourier-domain OCT (38.89 ± 4.46 D) was significantly lower than standard keratometry (40.50 ± 3.61 D). The average difference was −1.61 ± 1.29 D (p < 0.001). The differences were more negative for corneas with lower net powers (Fig. 1). For the hyperopic LVC group, the difference between net corneal power measured by Fourier-domain OCT (45.59 ± 1.18 D) and standard keratometry (45.74 ± 1.31 D) was not significant (p = 0.49).

Figure 1.

Figure 1

Bland–Altman plot assessing the agreement between net corneal powers measured by OCT and IOL-Master automated keratometry. Assuming normal distribution, the 95% confidence interval is given by mean ± 1.96 times the standard deviation (SD).

The ECP calculation formulae for the myopic group and hyperopic group are shown in Figs. 2 and 3, respectively. Data from the two sites seemed to follow the same trend lines for both myopic group and hyperopic group.

Figure 2.

Figure 2

Effective corneal power for eyes after myopic laser vision correction (n = 16 eyes of 16 subjects). ECP = effective corneal power. NCP = net corneal power. Square = data from Doheny Eye Institute. Diamond = data from Cullen Eye Institute.

Figure 3.

Figure 3

Effective corneal power for eyes after hyperopic laser vision correction (n = 8 eyes of 8 subjects). ECP = effective corneal power. NCP = net corneal power. Square = data from Doheny Eye Institute. Diamond = data from Cullen Eye Institute.

Predictive accuracy of intraocular power calculation

We compared the error of predicting the postoperative refraction (predicted − actual MRSE) for OCT-based IOL formula with the results for the Haigis-L formula (Table 1). For the myopic LVC group, the MAE of OCT-based formula was 0.57 D while the MAE was 0.73 D for Haigis-L (p = 0.19). There was a trend toward fewer large prediction errors using OCT (Fig. 4), with 18 eyes (82%) being within 1 D of actual refractive outcome, compared to 16 eyes (73%) within 1 D for Haigis-L. The difference was not significant. A Bland–Altman plot of prediction errors of OCT and Haigis-L formulas are shown in Fig. 5.

Table 1.

Accuracy of OCT-based IOL power formula compared with Haigis-L.

Keratometry method Best IOL formula Prediction error (D) Range (D) MAE (D)
After myopic LVC (n = 22 eyes)
IOL Master Haigis-L, myopic −0.35 ± 0.94 (−2.32, 1.30) 0.73
OCT OCT 0.07 ± 0.80 (−1.24, 2.15) 0.57
After hyperopic LVC (n = 9 eyes)
IOL Master Haigis-L, hyperopic 0.36 ± 0.72 (−0.61, 1.71) 0.54
OCT OCT −0.08 ± 0.34 (−0.64, 0.44) 0.26

LVC = laser vision correction. Prediction error = predicted MRSE − actual MRSE 1 month after surgery; MRSE = manifest refraction spherical equivalent. MAE = mean absolute prediction error in MRSE.

Figure 4.

Figure 4

Distribution of prediction errors in spherical equivalent manifest refraction for Haigis-L and OCT-based IOL formula in eyes after myopic laser vision correction. For OCT formula, 18 out of 22 eyes were within 1 D of actual refractive outcome, compared to 16 eyes within 1 D for Haigis-L formula.

Figure 5.

Figure 5

Bland–Altman plot assessing the agreement between prediction errors in spherical equivalent manifest refraction for Haigis-L and OCT-based IOL formula in eyes after myopic laser vision correction (n = 22 eyes of 16 subjects).

For the hyperopic LVC group, the MAE of OCT-based IOL formula was 0.26 D while the MAE was 0.54 D for Haigis-L (p > 0.05). There was also a trend toward fewer large prediction errors using OCT (Fig. 6), with 9 eyes (100%) being within 1 D of the actual refractive outcome, compared to 7 eyes (78%) within 1 D for Haigis-L. The difference was not significant. A Bland–Altman plot of prediction errors of OCT and Haigis-L formulas are shown in Fig. 7.

Figure 6.

Figure 6

Prediction errors in spherical equivalent manifest refraction for Haigis-L and OCT-based IOL formula in eyes after hyperopic laser vision correction (n = 9 of 8 subjects). For OCT formula, 9 out of 9 eyes were within 1 D of actual refractive outcome, compared to 7 eyes within 1 D for Haigis-L formula.

Figure 7.

Figure 7

Bland–Altman plot assessing the agreement between prediction errors in spherical equivalent manifest refraction for Haigis-L and OCT-based IOL formula in eyes after hyperopic laser vision correction (n = 9 of 8 subjects).

Discussions

Laser vision correction was introduced in the 1980s.28,29 By now, many of the early patients have reached an age when cataracts are common,30–32 and some already have had cataract surgery.2,12,33–35 With millions of LVC procedures done each year, the number of cataract patients with previous LVC will eventually reach a similar magnitude. Therefore, an accurate method for selecting IOL power in these patients will be increasingly important. The main challenge in calculating IOL power in these cases is measuring the true posterior corneal power, because the assumption of a fixed relationship between anterior and posterior curvatures no longer applies after LVC. Thus standard keratometry can produce large errors in corneal power estimate and conventional IOL formulae can easily lead to significant un-intended hyperopic or myopic outcome.

Many methods have been proposed to improve the accuracy of IOL power selection for post-LVC eyes. The clinical history method36 and the rigid gas-permeable contact lens over-refraction method37,38 are well known because they were introduced early. These methods have obvious limitations. Historical data on keratometry and refraction taken around the time of LVC may not be readily available, and even if they were, may not account for corneal changes since the initial LVC procedure. Contact lens overrefraction suffers from the relatively inaccurate visual endpoint in cataract patients, who may have significantly decreased vision due to cataract.39 Other investigators have also found these two methods to perform poorly relative to newer methods.39,40

Some of the newer methods for post-LVC IOL calculation do not rely on historical data or refraction. One class of methods uses a standard keratometer but calculates the corneal power in alternative fashions more suitable for post-LVC eyes. The Koch method uses standard keratometry to measure the anterior corneal power, and then add a constant posterior corneal power.34 The Haigis-L formula uses empirical linear regression analysis of post-LVC cataract surgery results to optimize the estimate of corneal power from standard keratometry.27 Theoretically, these methods should work well for eyes with average posterior curvature, but could err in eyes that are much steeper or flatter than the average. We included the Haigis-L IOL formula in the current study because it is relatively well studied27 and is available on the commonly used IOLMaster biometer as well as the ASCRS IOL calculator website (http://iol.ascrs.org). We found that OCT-based IOL calculation had similar predictive accuracy with the Haigis-L formula.

Because the lack of accurate measurement posterior corneal power is the main cause of the error in post-LVC IOL power calculation, the direct measurement of posterior corneal power is potentially the optimal solution. OCT as well as slit scanning instruments such as the Orbscan II, Pentacam, and Galilei all have such capability. Theoretically, compared to OCT, slit scanning has a relatively poor axial resolution of 50–100 microns due to the diffraction limit of optical focusing. The poor resolution can lead to large errors in the detection of the corneal surface boundaries in the presence of corneal haze or opacity, a problem that was well documented in the Orbscan II.20–23 We will perform the comparison between OCT and slit scanning instruments in other studies.

In summary, we have shown that OCT-based IOL power calculation performs at least as well as a regression-optimized post-LVC IOL formula (Haigis-L). Future improvements in hardware and software of OCT systems can be anticipated to further improve corneal power measurement and IOL power selection. This is a promising technology that could eventually become the best way to calculate IOL power for post-LVC cataract surgery.

Financial and proprietary interest

Maolong Tang, Yan Li, and David Huang have significant financial interests in Optovue Inc., a company that may have a commercial interest in the results of this research and technology. This potential individual conflict of interest has been reviewed and managed by the Oregon Health & Science University. Li Wang received research support from Ziemer. Douglas D. Koch is a consultant for Alcon Surgical Inc.

Financial support

This study was supported by NIH grants R01 EY018184 and a grant from Optovue Inc.

References

  • 1.Speicher L., Gottinger W. Intraocular lens power calculation after decentered photorefractive keratectomy. J Cataract Refract Surg. 1999;25(1):140–143. doi: 10.1016/s0886-3350(99)80024-8. [DOI] [PubMed] [Google Scholar]
  • 2.Hamilton D.R., Hardten D.R. Cataract surgery in patients with prior refractive surgery. Curr Opin Ophthalmol. 2003;14(1):44–53. doi: 10.1097/00055735-200302000-00008. [DOI] [PubMed] [Google Scholar]
  • 3.Holladay J.T., Prager T.C., Chandler T.Y. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14(1):17–24. doi: 10.1016/s0886-3350(88)80059-2. [DOI] [PubMed] [Google Scholar]
  • 4.Sanders D.R., Retzlaff J.A., Kraff M.C. Comparison of the SRK/T formula and other theoretical and regression formulas. J Cataract Refract Surg. 1990;16(3):341–346. doi: 10.1016/s0886-3350(13)80706-7. [DOI] [PubMed] [Google Scholar]
  • 5.Hoffer K.J. The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg. 1993;19(6):700–712. doi: 10.1016/s0886-3350(13)80338-0. [DOI] [PubMed] [Google Scholar]
  • 6.Olsen T. On the calculation of power from curvature of the cornea. Br J Ophthalmol. 1986;70(2):152–154. doi: 10.1136/bjo.70.2.152. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Mandell R.B. Corneal power correction factor for photorefractive keratectomy. J Refract Corneal Surg. 1994;10(2):125–128. [PubMed] [Google Scholar]
  • 8.Gobbi P.G., Carones F., Brancato R. Keratometric index, videokeratography, and refractive surgery. J Cataract Refract Surg. 1998;24(2):202–211. doi: 10.1016/s0886-3350(98)80201-0. [DOI] [PubMed] [Google Scholar]
  • 9.Savini G., Barboni P., Zanini M. Correlation between attempted correction and keratometric refractive index of the cornea after myopic excimer laser surgery. J Refract Surg. 2007;23(5):461–466. doi: 10.3928/1081-597X-20070501-07. [DOI] [PubMed] [Google Scholar]
  • 10.Koch D.D., Foulks G.N., Moran C.T., Wakil J.S. The Corneal EyeSys System: accuracy analysis and reproducibility of first-generation prototype. Refract Corneal Surg. 1989;5(6):424–429. [PubMed] [Google Scholar]
  • 11.Seitz B., Langenbucher A., Nguyen N.X. Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy. Ophthalmology. 1999;106(4):693–702. doi: 10.1016/S0161-6420(99)90153-7. [DOI] [PubMed] [Google Scholar]
  • 12.Zientara S., MacLachlan N.J., Calistri P. Bluetongue vaccination in Europe. Expert Rev Vaccines. 2010;9(9):989–991. doi: 10.1586/erv.10.97. [DOI] [PubMed] [Google Scholar]
  • 13.Koch D.D. New options for IOL calculations after refractive surgery. J Cataract Refract Surg. 2006;32(3):371–372. doi: 10.1016/j.jcrs.2006.01.034. [DOI] [PubMed] [Google Scholar]
  • 14.Srivannaboon S., Reinstein D.Z., Sutton H.F., Holland S.P. Accuracy of Orbscan total optical power maps in detecting refractive change after myopic laser in situ keratomileusis. J Cataract Refract Surg. 1999;25(12):1596–1599. doi: 10.1016/s0886-3350(99)00286-2. [DOI] [PubMed] [Google Scholar]
  • 15.Leyland M. Validation of Orbscan II posterior corneal curvature measurement for intraocular lens power calculation. Eye. 2004;18(4):357–360. doi: 10.1038/sj.eye.6700659. [DOI] [PubMed] [Google Scholar]
  • 16.Sonego-Krone S., Lopez-Moreno G., Beaujon-Balbi O.V. A direct method to measure the power of the central cornea after myopic laser in situ keratomileusis. Arch Ophthalmol. 2004;122(2):159–166. doi: 10.1001/archopht.122.2.159. [DOI] [PubMed] [Google Scholar]
  • 17.Li Y., Tang M., Zhang X. Pachymetric mapping with Fourier-domain optical coherence tomography. J Cataract Refract Surg. 2010;36(5):826–831. doi: 10.1016/j.jcrs.2009.11.016. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Borasio E., Stevens J., Smith G.T. Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula. J Cataract Refract Surg. 2006;32(12):2004–2014. doi: 10.1016/j.jcrs.2006.08.037. [DOI] [PubMed] [Google Scholar]
  • 19.Qazi M.A., Cua I.Y., Roberts C.J., Pepose J.S. Determining corneal power using Orbscan II videokeratography for intraocular lens calculation after excimer laser surgery for myopia. J Cataract Refract Surg. 2007;33(1):21–30. doi: 10.1016/j.jcrs.2006.08.026. [DOI] [PubMed] [Google Scholar]
  • 20.Khurana R.N., Li Y., Tang M. High-speed optical coherence tomography of corneal opacities. Ophthalmology. 2007;114(7):1278–1285. doi: 10.1016/j.ophtha.2006.10.033. [DOI] [PubMed] [Google Scholar]
  • 21.Boscia F., La Tegola M.G., Alessio G., Sborgia C. Accuracy of Orbscan optical pachymetry in corneas with haze. J Cataract Refract Surg. 2002;28(2):253–258. doi: 10.1016/s0886-3350(01)01162-2. [DOI] [PubMed] [Google Scholar]
  • 22.Kim S.W., Byun Y.J., Kim E.K., Kim T.I. Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry. J Refract Surg. 2007;23(9):888–894. doi: 10.3928/1081-597X-20071101-04. [DOI] [PubMed] [Google Scholar]
  • 23.Prisant O., Calderon N., Chastang P. Reliability of pachymetric measurements using orbscan after excimer refractive surgery. Ophthalmology. 2003;110(3):511–515. doi: 10.1016/S0161-6420(02)01298-8. [DOI] [PubMed] [Google Scholar]
  • 24.Tang M., Li Y., Avila M., Huang D. Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography. J Cataract Refract Surg. 2006;32(11):1843–1850. doi: 10.1016/j.jcrs.2006.04.046. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Tang M., Chen A., Li Y., Huang D. Corneal power measurement with Fourier-domain optical coherence tomography. J Cataract Refract Surg. 2010;36(12):2115–2122. doi: 10.1016/j.jcrs.2010.07.018. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Tang M., Li Y., Huang D. An intraocular lens power calculation formula based on optical coherence tomography: a pilot study. J Refract Surg. 2010;26(6):430–437. doi: 10.3928/1081597X-20090710-02. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Haigis W. Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J Cataract Refract Surg. 2008;34(10):1658–1663. doi: 10.1016/j.jcrs.2008.06.029. [DOI] [PubMed] [Google Scholar]
  • 28.Munnerlyn C.R., Koons S.J., Marshall J. Photorefractive keratectomy: a technique for laser refractive surgery. J Cataract Refract Surg. 1988;14(1):46–52. doi: 10.1016/s0886-3350(88)80063-4. [DOI] [PubMed] [Google Scholar]
  • 29.McDonald M.B., Frantz J.M., Klyce S.D. One-year refractive results of central photorefractive keratectomy for myopia in the nonhuman primate cornea. Arch Ophthalmol. 1990;108(1):40–47. doi: 10.1001/archopht.1990.01070030046026. [DOI] [PubMed] [Google Scholar]
  • 30.Klein B.E., Klein R., Lee K.E., Gangnon R.E. Incidence of age-related cataract over a 15-year interval the Beaver Dam Eye Study. Ophthalmology. 2008;115(3):477–482. doi: 10.1016/j.ophtha.2007.11.024. [DOI] [PubMed] [Google Scholar]
  • 31.Rochtchina E., Mukesh B.N., Wang J.J. Projected prevalence of age-related cataract and cataract surgery in Australia for the years 2001 and 2021: pooled data from two population-based surveys. Clin Experiment Ophthalmol. 2003;31(3):233–236. doi: 10.1046/j.1442-9071.2003.00635.x. [DOI] [PubMed] [Google Scholar]
  • 32.Tan A.G., Wang J.J., Rochtchina E. Increase in cataract surgery prevalence from 1992–1994 to 1997–2000: analysis of two population cross-sections. Clin Experiment Ophthalmol. 2004;32(3):284–288. doi: 10.1111/j.1442-9071.2004.00817.x. [DOI] [PubMed] [Google Scholar]
  • 33.Kalski R.S., Danjoux J.P., Fraenkel G.E. Intraocular lens power calculation for cataract surgery after photorefractive keratectomy for high myopia. J Refract Surg. 1997;13(4):362–366. doi: 10.3928/1081-597X-19970701-12. [DOI] [PubMed] [Google Scholar]
  • 34.Koch D.D., Wang L. Calculating IOL power in eyes that have had refractive surgery. J Cataract Refract Surg. 2003;29(11):2039–2042. doi: 10.1016/j.jcrs.2003.10.009. [DOI] [PubMed] [Google Scholar]
  • 35.Latkany R.A., Chokshi A.R., Speaker M.G. Intraocular lens calculations after refractive surgery. J Cataract Refract Surg. 2005;31(3):562–570. doi: 10.1016/j.jcrs.2004.06.053. [DOI] [PubMed] [Google Scholar]
  • 36.Holladay J.T. In discussion of: Determining the power of an intraocular lens to achieve a postoperative correction of −1.00 D. Refract Corneal Surg. 1989;5:203. [PubMed] [Google Scholar]
  • 37.Zeh W.G., Koch D.D. Comparison of contact lens overrefraction and standard keratometry for measuring corneal curvature in eyes with lenticular opacity. J Cataract Refract Surg. 1999;25(7):898–903. doi: 10.1016/s0886-3350(99)00088-7. [DOI] [PubMed] [Google Scholar]
  • 38.Holladay J.T. Cataract surgery in patients with previous keratorefractive surgery (RK, PRK and LASIK) Ophthalmol Practice. 1997;15:238–244. [Google Scholar]
  • 39.Wang L., Booth M.A., Koch D.D. Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK. Ophthalmology. 2004;111(10):1825–1831. doi: 10.1016/j.ophtha.2004.04.022. [DOI] [PubMed] [Google Scholar]
  • 40.Savini G., Hoffer K.J., Carbonelli M., Barboni P. Intraocular lens power calculation after myopic excimer laser surgery: clinical comparison of published methods. J Cataract Refract Surg. 2010;36(9):1455–1465. doi: 10.1016/j.jcrs.2010.02.029. [DOI] [PubMed] [Google Scholar]

Articles from Saudi Journal of Ophthalmology are provided here courtesy of Wolters Kluwer -- Medknow Publications

RESOURCES