Abstract
Background
Fine needle aspiration biopsy is usually performed to evaluate thyroid lesions. The purpose of this study was to evaluate the usefulness of diffusion weighted imaging to differentiate malignancy of thyroid lesions.
Methods
The study was approved by ethics committee of Shanghai Changzheng Hospital.Forty-two patients, 10 men and 32 women (range: 20–72 years, mean age 42.4 years) with thyroid lesions were included in the study. Routine neck MR and diffusion-weighted MR imaging was performed using multiple b-values. ADC values were computed for the different b-values. Histological results of the thyroidectomy samples were obtained for all the patients. ADC values of benign and malignant thyroid lesions were compared with the pathology results. Logistic regression analysis was used to detect independent parameters for differentiating benign and malignancy of lesions.
Result
Based on the histology results there were 28 benign and 14 malignant cases. The difference of ADC value between benign and malignant thyroid lesions was significant for ADC values obtained using b-values of 0 and 300 s/mm2 (p < 0.001). The ADC values were significantly higher in benign lesions (benign ADC: 2.37 ± 0.47 × 10-3 mm2/s vs. malignant: 1.49 ± 0.60 × 10-3 mm2/s). ADC values obtained with b-values of 0 and 300 mm2/s and max nodular diameter was regarded as the two most discriminative parameters for differentiating malignancy. Using the pathology results as a standard reference, area under ROC curve was found to be 0.876 for an ADC cutoff value of 2.17 × 10-3 mm2/s that corresponded to an acquisition with b-values of 0 and 300 mm2/s.
Conclusion
Diffusion-weighted MR imaging is a promising non-invasive method to differentiate malignancy in thyroid lesions.
Keywords: Thyroid lesions, Diffusion weighted imaging, ADC mapping
Background
Incidence and prevalence of thyroid disease has seen a great increase in recent years. An increasing incidence of thyroid cancer has been reported worldwide [1-3]. The reported incidence of thyroid cancer is up to 0.07% over the past 30 years [4]. 44,670 new cases and 1,690 deaths were attributed to thyroid cancer in 2010 [5]. Fine needle aspiration biopsy (FNAB) is regarded as the standard reference for diagnosis, but it has been reported before that FNAB results may mimic some other diseases [6-8]. Ultrasound is the most common non-invasive and sensitive diagnostic imaging modality for diagnosing thyroid lesions, but there are still no reliable criteria for distinguishing benign from malignant lesions. In addition, it is difficult to access the malignancy of the nodule when it is large or multinodular [9]. Despite tremendous improvement in diagnostic techniques such as ultrasound, radionuclide imaging and CT, there is still a big challenge to have a non-invasive and reliable technique to differentiate benign from malignant lesions. Recent developments in MRI may show that some MR protocols are of diagnostic value for these types of lesions [10]. Routine T1- and T2-weighted MR imaging can provide information on the location and size of thyroid lesions. But these protocols still don’t have the specificity for distinguishing benign from malignant nodules or assessing the functional status of these thyroid nodules.
Diffusion-weighted MR imaging (DWI) is an emerging technique for central nervous system (CNS) diseases. DWI is sensitive to changes in the microstructural organization of tissue that may affect water diffusion. It has been used in various forms to evaluate head and neck tumors [11-13]. The Apparent Diffusion Coefficient (ADC) value, a metric obtained from DWI scans, could be a quantitative parameter for distinguishing malignant tumors from benign lesions.
In our current study, we compared ADC values of thyroid lesions with their pathology reports in order to evaluate its usefulness for distinguishing malignancy.
Methods
Patient selection
Between July 2007 and Jan 2011, 42 patients (10 male; 32 female) with palpable or ultrasonography determined thyroid nodules were prospectively enrolled and patient consent was obtained. The study was approved by ethics committee of Shanghai Changzheng Hospital. Mean age of those patients was 42.9 yrs (range 20-72 yrs). Routine neck MR imaging and diffusion-weighted MR imaging was performed for each patient. All patients enrolled for this study have been scheduled to have thyroidectomy within 2 weeks. Thyroidectomy was performed afterwards and pathology results were obtained for each patient. Conventional histology revealed that 28 patients had benign lesions, including thyroid adenoma (N = 20), nodular goiter (N = 5), and Hashimoto's thyroiditis (N = 3) while 14 patients were found to have malignant lesions, including thyroid papillary carcinoma (N = 10), follicular thyroid cancer (N = 3), atypical hyperplasia (N = 1). Thyroid lesions less than 1 cm were excluded because of diagnostic difficulties in evaluation.
MRI protocol
MR scanning was performed on GE Signa HD 1.5 T MR scanner (GE healthcare, USA). Routine MRI examinations were done with the following parameters: fast spin echo FSE scanning for neck, axial T1WI (TR = 520 ms, TE = 14 ms), T2WI (TR = 3500 ms, TE = 95 ms) and coronal T2WI (TR = 3000 ms, TE = 85 ms). Thickness = 4 mm, Spacing = 1 mm. FOV = 14 cm × 14 cm, Matrix = 320 × 256, NEX = 4.
Diffusion Weighted MR Imaging (DWI) was acquired using four different b factors (0, 300, 500, and 800 s/mm2) in a STIR fat suppressed SE-EPI sequence. All DWI scans were acquired with the same parameters:TR = 3000 ms, TE = 60 ms, Matrix = 96 × 128, thickness - 4 mm and 6 averages were obtained. Total scanning time of about 10 minutes for the DWI scan.
Image post processing
Using the post processing software Functool from GE, ADC maps were automatically generated for each of the b factors. ADC values were extracted from ADC maps. Circular ROIs (regions of interests)with an area of 1 cm2 were carefully placed on the lesions (areas of necrosis, hemorrhage, calcium and cyst formation were excluded). ROIs were placed on one ADC map and then propagated to the other 2 by two experienced radiologists blinded to each other’s delineations. To minimize noise, each radiologist made three measurements for each lesion and the mean ADC value was recorded. Interrater reliability of the ROIs ADC values had ICC > 0.87. Final ADC value was determined by the mean values from two raters.
Analysis
ADC maps were computed for each of the b-values used in the DWI protocol. This was done automatically for the b-factors of 300 s/mm2, 500 s/mm2 and 800 s/mm2. ADC values were extracted from the ADC maps. Statistical analysis was performed using the Statistical Package for the Social Sciences for Windows (SPSS, Chicago, Ill). All ADC data were recorded in Mean ± SD (×10-3 mm2/s) form. Mann–Whitney U-test was performed to compare the quantitative ADC value of benign and malignant thyroid nodules. A value of p < .05 was considered significant. In addition, receiver operating characteristic (ROC) curve was constructed to determine a cutoff value for differentiating benign and malignant thyroid lesions. Receiver operating characteristic (ROC) curves were constructed and areas under the ROC curve (Az) were computed using MedCalc version 10.2.0.0 (http://www.medcalc.com/).
Results
MRI results revealed that among those 42 cases of lesions in the thyroid, 10 were located in the left lobe of thyroid gland, 16 of were in the right lobes, 14 had lesions on both lobes and 2 lesions were in thyroid isthmus. For those with lesions on both lobes, one was randomly chosen (matched with pathology) for ADC measurements. Mean major diameter of the benign and malignant lesions were 3.63 cm and 2.55 cm respectively. Historical findings confirmed there were 28 benign cases and 14 malignant lesions. Independent of malignancy, thyroid lesions occurred more frequently in female than in male (Table 1).
Table 1.
Histological categories | Number (%) | Mean age (yrs) | Female (%) | Mean maximum diameter (cm) |
---|---|---|---|---|
Benign |
28(66.7) |
41.7 |
21(75) |
3.63 ± 0.37 |
Thyroid adenoma |
20(47.6) |
42.6 |
15(53.6) |
3.53 ± 0.25 |
Nodular goiter |
6(14.3) |
39.3 |
5(17.9) |
3.95 ± 0.65 |
Hashimoto's thyroiditis |
2(4.8) |
35.6 |
1(3.6) |
3.71 ± 0.11 |
Malignant |
14(33.3) |
45.3 |
11(78.6) |
2.55 ± 0.41 |
Thyroid papillary carcinoma |
11(26.2) |
41.9 |
9(64.4) |
2.73 ± 0.54 |
Follicular thyroid cancer |
2(4.8) |
49.1 |
1(7.1) |
1.7 ± 0.13 |
Atypical hyperplasia | 1(2.4) | 45 | 1(7.1) | 2.3 |
Parameters for differentiating lesion malignancy
Using histology results to group the ADC values we found that the ADC values were significantly different (p < 0.001) between benign and malignant lesions for the ADC values computed for b = 300 s/mm2. Mean ADC value for benign group (Figure 1) is much higher than that for malignant group (Figure 2), with the values of 2.37 ± 0.47 × 10-3 mm2/s and 1.49 ± 0.60 × 10-3 mm2/s respectively. However, no significant difference was observed between the two groups for the ADC values obtained using b = 500 s/mm2 or 800 s/mm2 (Table 2). Sensitivity, specificity and AUC were also compared among three different b-factors. Highest sensitivity and AUC was observed at b-factor of 300 s/mm2 (Table 3).We also selected four variables (age, sex, ADC value, max nodular diameter) as independent variables to perform logistic regression analysis. Odds ratios (and 95% CIs) based on the logistic regression model were also calculated. The results obtained from the logistic regression model showed that ADC values obtained with a b factor of 300 s/mm2 (OR = 4.76, p <0.001) and max nodular diameter (OR = 3.22, p = 0.034) were the two most discriminative independent variables for differentiating between benign and malignant lesions (Table 2).
Table 2.
Benign group (n = 28) | Malignant group (n = 14) | P value* | OR | 95% CI | |
---|---|---|---|---|---|
Age (yrs) |
41.7 |
45.3 |
0.79 |
0.62 |
0.26, 2.59 |
Sex (Female %) |
21(75) |
11(78.6) |
0.61 |
0.50 |
0.16, 1.54 |
Max nodular diameter (cm) |
3.63 ± 0.37 |
2.55 ± 0.41 |
0.034 |
3.22 |
1.27, 6.76 |
ADC values [mm2/s] |
|
|
|
|
|
b-0,300 |
2.37 ± 0.47 |
1.49 ± 0.60 |
<0.001 |
4.76 |
1.56, 9.89 |
b-0,500 |
1.87 ± 0.25 |
1.61 ± 0.45 |
0.138 |
1.01 |
0.3, 1.81 |
b-0,800 | 1.68 ± 0.25 | 1.41 ± 0.34 | 0.059 | 0.091 | 0.03, 0.73 |
*p value reflected from logistic analysis.
Table 3.
b = 0,300 | b = 0,500 | b = 0,800 | |
---|---|---|---|
AUC |
0.88(0.77–0.97) |
0.63(0.47–0.77) |
0.63(0.46–0.77) |
Criterion [10-3 mm2/s] |
>2.17 |
>1.74 |
>1.65 |
Sensitivity % |
76.5 |
67.9 |
53.6 |
Specificity % | 100 | 64.3 | 71.4 |
ROC analysis
Furthermore, a Receiver Operator Characteristic (ROC) curve was computed for the ADC values obtained from DWI scans using b = 300 s/mm2. We determined a cutoff point from the ROC curve that would differentiate benign from malignant lesions. The area under the ROC curve was 0.876. When we selected a cutoff ADC value of 2.17 × 10-3 mm2/s, sensitivity and specificity was found to be 76.5% and 100% respectively (Figure 3).
Discussion
To date, only a few studies have focused on the use of DWI in evaluating thyroid disease. Tezuka [14] et al. used both routine T1WI, T2WI and DWI techniques to diagnose thyroid diseases (Graves’ disease, sub-acute thyroiditis and Hashimoto's disease). Although no obvious difference using T1WI and T2WI were detected on those thyroid diseases, ADC values of thyroid lesions of Graves’ disease was found much higher than that of sub-acute thyroiditis or Hashimoto's disease. An ADC value of 1.82 × 10-3 mm2/s was suggested as the cutoff point to diagnose Graves’ disease (Sensitivity 75% and Specificity 80%). DWI has emerged as a potential new noninvasive technique that can provide more quantitative information on thyroid lesions and help make clinical differential diagnosis.
MR technique
Diffusion weighted MR imaging can be done with single shot or multi-shot. Wang and Adel Razek [11,15] applied single-shot multisection echo-planar technique, using b values of 0, 500 and 1000 s/mm2 respectively. This sequence is characterized by a train of gradient echoes with a short echo time image and good signal-to-noise ratio (SNR), but it was associated with more magnetic susceptibility artifacts. Tezuka [14] et al., used a fast spin echo sequence for diffusion-weighted imaging to avoid magnetic susceptibility artifacts, but not only was the imaging time increased but the SNR was also decreased.
In this study, we used a STIR (Short TI Inversion Recovery) fat suppressed SE EPI (Spin-Echo Echo Planar Imaging) sequence. STIR is a very robust fat suppression technique with minimal artifacts. It has low sensitivity to magnetic field inhomogeneities or susceptibility effects and thus improves image quality. It also produces a slight T1-weighted background suppression but does not affect the accuracy of the images. EPI is the fastest acquisition method and it only requires 30 ms ~ 100 ms to collect one image which helps in reducing most physiological movement artifacts [16]. Furthermore, short TE time of 60 ms was used to reduce T2* effect in our study. Thus, using this sequence we were able to obtain more accurate tissue ADC values.
The b-factor in the DWI was an important factor for image quality. We obtained diffusion-weighted MR images with different b factors simultaneously to avoid misregistration in computing the different ADC values. Higher b-values produce more diffusion weighting and therefore higher contrast between thyroid lesions and normal tissue. However, higher b value also leads to increased signal attenuation and usually required more averages to compensate for the SNR. Higher b-values also produce more susceptibility distortions and could increase the noise in the DWI images because the distortions are different depending on the gradient directions. In addition, different tumors within different organs or tissues may be more sensitive to different b-values. In this study, we applied an SE EPI diffusion imaging with b-factors of 300, 500 and 800 s/mm2. Our results showed that a b-factor of 300 s/mm2 was sufficient to obtain high quality ADC values and it was also the one with had a high sensitivity and accuracy for differentiating benign and malignancy. These results are consistent with Bozgeyik’s [17] results.
Pathological mechanism of ADC values in thyroid lesions
In our study we were able to use the most reliable reference for malignancy which was based on the histopathology of a thyroidectomy. Our results showed a significant difference in the ADC value between benign and malignant thyroid lesions, with ADC values in benign lesions being higher than malignant lesions (2.37 ± 0.47 × 10-3 mm2/s vs. 1.49 ± 0.60 × 10-3 mm2/s) at the b factor of 300 s/mm2. These results are consistent with other similar studies [17-19]. Diffusion weighted imaging provides more information on the microstructure of tissues and their physiological processes. Changes in the distributions of intracellular organelles and macromolecules in the tissues affect the random motion of water protons. ADC values of tissues vary according to its cellularity and histopathology. Anderson [20]’s study showed that malignant lesions in thyroid glands was characterized by compact cellularity which increased the nucleocyte-cytoplasmic ratio (NCR). These microscopic pathological changes results in the reduction of extracellular space which limits diffusional motion of water protons. Reduced ADC values are presented as high signal on DWI sequences.
Abdel’s [21] study demonstrated that when selecting ADC value of 0.98 × 1.0-3 mm2/s as a cutoff point to differentiate benign and malignant lesions, the sensitivity and specificity was 97.5% and 91.7%, respectively. The accuracy was up to 98.9%. In this study a single pair of b-values (0, 1000 s/mm2) were studied. Although we also looked at the ADC values obtained using higher b-values (0,800 s/mm2), we did not detect any useful threshold at the higher b-values. Abdel’s study included a variety of cervical lymph nodes whereas our study focused on the thyroid. Lesion heterogeneity might have accounted for the differences in sensitivity. It was also suggested that the ADC values of benign thyroid nodule may vary according to the complex composition within the nodule (colloid, tiny necrosis and cystic change, hemorrhage, fibrosis and calcium). ADC values were highest in thyroid cysts since it contained colloid cyst made of serous or concentrated thyroglobulin. Conversely, increasing NCR and grit-like calcification mainly lead to a decrease of ADC values in papillary thyroid carcinoma.
Bozgeyik [17] also studied thyroid nodules with DWI at lower b-values. Bozgeyik [17] also found that a b-factor of 300 s/mm2 was the most useful for differentiating benign or malignant lesions. In Bozgeyik’s study 3 b-value pairs were used to computed the ADC (0, 100 s/mm2), (0, 200 s/mm2) and (0, 300 s/mm2). We expanded on these results and investigated ADC values obtained using larger b-values. Our sample includes about 33% malignancy rates whereas in Bozgevik’s study less than 5% of the nodules were malignant. In their study, malignancy was determined using FNAB whereas in our study we have used pathology results from thyroidectomy, a more accurate reference. Erdem [19] also suggested that tiny calcification was closely correlated with the reduction of ADC values in thyroid malignancy.
However, in Weidekamm’s [22,23] study, the opposite result was reported. ADC values were predominantly higher in malignant thyroid nodules than that in benign nodules with values equal or more than 2.25 × 10-3 mm2/s. The higher ADC values may be due to the over production of thyroprotein follicle in malignant thyroid nodules which do not restrict the diffusion of the water protons.
ADC values has been used as a quantitative parameter for differentiating benign and malignant lesions [24]. The ADC values depend on many factors such as tissue microstructure, necrosis, presence of macromolecules and also perfusion phenomenon. When compared to benign lesions, abnormal blood perfusion is more prevalent in malignant lesions and ADC values will be affected by both blood perfusion and extracellular space. Unlike some other studies [17], in the current study, we chose three different b factors all over 300 s/mm2 since ADC value would better reflect the true water diffusion in the tissue with larger b factors. However, there was no significant difference in ADC value between benign and malignant lesions when the b factors were 500 s/mm2 and 800 s/mm2. Delormere [25] demonstrated that malignant lesions usually do not have a complete basal membrane of blood vessel which enhances the molecular exchange in the capillary bed. ADC values could be influenced by both blood perfusion and extracellular space. In thyroid malignancy, increased blood perfusion increases the apparent speed of the diffusing water protons while narrow extracellular space will restrict its movement. Although at higher b-values the sensitivity to perfusion is reduced, our results show no difference in ADC values between benign and malignant groups with b-values of 500 s/mm2 or 800 s/mm2. The ADC values obtained using the lower b-value of 300 s/mm2 is most likely affected by both perfusion and diffusion effects. It is possible that the discriminatory effect of this lower 300 s/mm2 reflect a combination of altered vascularity and changes in cellular composition that characterizes malignancy.
Fine-needle aspiration biopsy (FNAB) cytology can give 4 different results: benign, malignant, suspicious and non-diagnostic. No definite diagnosis is possible for the two categories of suspicious and non-diagnostic. Although FNAB is commonly used to screen for malignancy, a unique approach in this study is that we used histological results from thyroidectomy as the standard reference for distinguishing benign and malignant lesions. Based on final histological results, we were able to obtain a definite diagnosis of each lesion. ROC curves and cut off point for b-values are more accurate in this approach.
There are still some limitations in this study. First, the relatively small number (33.3%) of the malignant nodules somehow limits the statistical power. This study needs to be expanded further with a larger number of patients. B-values should be extended to lower values and higher ranges to verify that 300 s/mm2 is an optimal value. Second, thyroid nodules less than 10 mm were not included in this study. Improvement in the software of diffusion-weighted MR imaging will help in the detection of smaller lesions in future studies. Third, we have not studied the correlation of ADC values with subtypes of thyroid lesions such as cysts from hemorrhagic nodules because of the small number which would reduce its statistical power.
Conclusion
In conclusion, diffusion-weighted MR imaging is a relatively new and non-invasive approach to assess thyroid lesions. ADC values seem to be able to differentiate benign from malignant thyroid disease. Further studies should be performed to expand the utility of DWI in thyroid lesions.
Abbreviations
DWI: Diffusion-weighted imaging; ADC: Apparent diffusion coefficient; T1WI: T1 weighted imaging; T2WI: T2 weighted imaging; FNAB: Fine needle aspiration biopsy; ICC: Intraclass correlation coefficient; ROC: Receiver operating characteristic.
Competing interests
The authors declare that they have no competing interests.
Authors’ contributions
YW collect data from patients and drafted the manuscript. XY participated in the sequence alignment. WS participated in the sequence alignment. YD did postprocessing and measurement on images. YY did postprocessing and measurement on images. XT conceived of the study, and participated in its design and coordination. CT participated in the design of the study and performed the statistical analysis. All authors read and approved the final manuscript.
Pre-publication history
The pre-publication history for this paper can be accessed here:
Contributor Information
Yingwei Wu, Email: wuyw0103@hotmail.com.
Xiuhui Yue, Email: wuyw0103@gmail.com.
Weiwen Shen, Email: sww_281@sina.com.
Yushan Du, Email: sww_281@sina.com.
Ying Yuan, Email: yuany83@163.com.
Xiaofeng Tao, Email: cjr.taoxiaofeng@vip.163.com.
Cheuk Ying Tang, Email: cheukying.tang@mssm.edu.
Acknowledgments
The manuscript was supported by grant of National Natural Science Foundation of China (Dr. Xiaofeng Tao No. 81272802) and Key scientific and innovation grant of Education Commission of Shanghai (Dr. Yingwei Wu No. 12ZZ028). Outstanding academic leader of Shanghai Science and Technology Committee of Dr. Xiaofeng Tao (Grant No. 13XD1402400).
References
- Wong CK, Wheeler MH. Thyroid nodules: rational management. World J Surg. 2000;24:934–941. doi: 10.1007/s002680010175. [DOI] [PubMed] [Google Scholar]
- Brander A, Viikinkoski P, Nickels J, Kivisaari L. Thyroid gland: US screening in a random adult population. Radiology. 1991;181:683–687. doi: 10.1148/radiology.181.3.1947082. [DOI] [PubMed] [Google Scholar]
- Davies L, Welch HG. Increasing incidence of thyroid cancer in the United States, 1973–2002. JAMA. 2006;295:2164–2167. doi: 10.1001/jama.295.18.2164. [DOI] [PubMed] [Google Scholar]
- Mazzaferri EL, Harmer C, Mallick UK, Kendall-Taylor P. Practical management of thyroid cancer: a multidisciplinary approach. London: Springer; 2006. [Google Scholar]
- Jemal A, Siegel R, Xu J, Ward E. Cancer statistics, 2010. CA Cancer J Clin. 2010;60:277–300. doi: 10.3322/caac.20073. [DOI] [PubMed] [Google Scholar]
- Bakshi NA, Mansoor I, Jones BA. Analysis of inconclusive fine-needle aspiration of thyroid follicular lesions. Endocr Pathol. 2003;14:167–175. doi: 10.1385/EP:14:2:167. [DOI] [PubMed] [Google Scholar]
- Koike E, Yamashita H, Noguchi S, Murakami T, Ohshima A. et al. Effect of combining ultrasonography and ultrasound-guided fine-needle aspiration biopsy findings for the diagnosis of thyroid nodules. Eur J Surg. 2001;167:656–661. doi: 10.1080/11024150152619273. [DOI] [PubMed] [Google Scholar]
- McCoy KL, Jabbour N, Ogilvie JB, Ohori NP, Carty SE. et al. The incidence of cancer and rate of false-negative cytology in thyroid nodules greater than or equal to 4 cm in size. Surgery. 2007;142:837–844. doi: 10.1016/j.surg.2007.08.012. discussion 844 e831-833. [DOI] [PubMed] [Google Scholar]
- Solbiati L, Osti V, Cova L, Tonolini M. Ultrasound of thyroid, parathyroid glands and neck lymph nodes. Eur Radiol. 2001;11:2411–2424. doi: 10.1007/s00330-001-1163-7. [DOI] [PubMed] [Google Scholar]
- Kiyosue H, Miyake H, Komatsu E, Mori H. MRI of cervical masses of thymic origin. J Comput Assist Tomogr. 1994;18:206–208. doi: 10.1097/00004728-199403000-00006. [DOI] [PubMed] [Google Scholar]
- Wang J, Takashima S, Takayama F, Kawakami S, Saito A. et al. Head and neck lesions: characterization with diffusion-weighted echo-planar MR imaging. Radiology. 2001;220:621–630. doi: 10.1148/radiol.2202010063. [DOI] [PubMed] [Google Scholar]
- Eida S, Sumi M, Sakihama N, Takahashi H, Nakamura T. Apparent diffusion coefficient mapping of salivary gland tumors: prediction of the benignancy and malignancy. AJNR Am J Neuroradiol. 2007;28:116–121. [PMC free article] [PubMed] [Google Scholar]
- King CH, Higa AT, Culjat MO, Han SH, Bisley JW. et al. A pneumatic haptic feedback actuator array for robotic surgery or simulation. Stud Health Technol Inform. 2007;125:217–222. [PubMed] [Google Scholar]
- Tezuka M, Murata Y, Ishida R, Ohashi I, Hirata Y. et al. MR imaging of the thyroid: correlation between apparent diffusion coefficient and thyroid gland scintigraphy. Journal of magnetic resonance imaging: JMRI. 2003;17:163–169. doi: 10.1002/jmri.10247. [DOI] [PubMed] [Google Scholar]
- Abdel Razek AA, Soliman NY, Elkhamary S, Alsharaway MK, Tawfik A. Role of diffusion-weighted MR imaging in cervical lymphadenopathy. Eur Radiol. 2006;16:1468–1477. doi: 10.1007/s00330-005-0133-x. [DOI] [PubMed] [Google Scholar]
- Murtz P, Krautmacher C, Traber F, Gieseke J, Schild HH. et al. Diffusion-weighted whole-body MR imaging with background body signal suppression: a feasibility study at 3.0 Tesla. Eur Radiol. 2007;17:3031–3037. doi: 10.1007/s00330-007-0717-8. [DOI] [PubMed] [Google Scholar]
- Bozgeyik Z, Coskun S, Dagli AF, Ozkan Y, Sahpaz F. et al. Diffusion-weighted MR imaging of thyroid nodules. Neuroradiology. 2009;51:193–198. doi: 10.1007/s00234-008-0494-3. [DOI] [PubMed] [Google Scholar]
- Razek AA, Sadek AG, Kombar OR, Elmahdy TE, Nada N. Role of apparent diffusion coefficient values in differentiation between malignant and benign solitary thyroid nodules. AJNR Am J Neuroradiol. 2008;29:563–568. doi: 10.3174/ajnr.A0849. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Erdem G, Erdem T, Muammer H, Mutlu DY, Firat AK. et al. Diffusion-weighted images differentiate benign from malignant thyroid nodules. Journal of magnetic resonance imaging: JMRI. 2010;31:94–100. doi: 10.1002/jmri.22000. [DOI] [PubMed] [Google Scholar]
- Anderson JR, editor. Muir’sTextbook of Pathology. 13. London: Edward Arnold; 1992. [Google Scholar]
- Abdel Razek AA, Soliman NY, Elkhamary S, Alsharaway MK, Tawfik A. Role of diffusion-weighted MR imaging in cervical lymphadenopathy. Eur Radiol. 2006;16:1468–1477. doi: 10.1007/s00330-005-0133-x. [DOI] [PubMed] [Google Scholar]
- Schueller-Weidekamm C, Kaserer K, Schueller G, Scheuba C, Ringl H. et al. Can quantitative diffusion-weighted MR imaging differentiate benign and malignant cold thyroid nodules? Initial results in 25 patients. AJNR Am J Neuroradiol. 2009;30:417–422. doi: 10.3174/ajnr.A1338. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schueller-Weidekamm C, Schueller G, Kaserer K, Scheuba C, Ringl H. et al. Diagnostic value of sonography, ultrasound-guided fine-needle aspiration cytology, and diffusion-weighted MRI in the characterization of cold thyroid nodules. Eur J Radiol. 2010;73:538–544. doi: 10.1016/j.ejrad.2008.12.013. [DOI] [PubMed] [Google Scholar]
- Herneth AM, Guccione S, Bednarski M. Apparent diffusion coefficient: a quantitative parameter for in vivo tumor characterization. Eur J Radiol. 2003;45:208–213. doi: 10.1016/S0720-048X(02)00310-8. [DOI] [PubMed] [Google Scholar]
- Delorme S, Knopp MV. Non-invasive vascular imaging: assessing tumour vascularity. Eur Radiol. 1998;8:517–527. doi: 10.1007/s003300050428. [DOI] [PubMed] [Google Scholar]