CT Image Sequence Restoration Based on Sparse and Low-Rank Decomposition

Shuiping Gou 1,*, Yueyue Wang 1, Zhilong Wang 2, Yong Peng 3, Xiaopeng Zhang 2, Licheng Jiao 1, Jianshe Wu 1
Editor: Ge Wang4
PMCID: PMC3762821  PMID: 24023764

Abstract

Blurry organ boundaries and soft tissue structures present a major challenge in biomedical image restoration. In this paper, we propose a low-rank decomposition-based method for computed tomography (CT) image sequence restoration, where the CT image sequence is decomposed into a sparse component and a low-rank component. A new point spread function of Weiner filter is employed to efficiently remove blur in the sparse component; a wiener filtering with the Gaussian PSF is used to recover the average image of the low-rank component. And then we get the recovered CT image sequence by combining the recovery low-rank image with all recovery sparse image sequence. Our method achieves restoration results with higher contrast, sharper organ boundaries and richer soft tissue structure information, compared with existing CT image restoration methods. The robustness of our method was assessed with numerical experiments using three different low-rank models: Robust Principle Component Analysis (RPCA), Linearized Alternating Direction Method with Adaptive Penalty (LADMAP) and Go Decomposition (GoDec). Experimental results demonstrated that the RPCA model was the most suitable for the small noise CT images whereas the GoDec model was the best for the large noisy CT images.

Introduction

Accurate display of anatomical detail, in the form of small structures, features and objects, is a key requirement of computed tomography (CT). These details carry important information that may be associated with distinction between normal and pathological diagnosis. However, blurring of the CT images often compromises the visibility of such fine details.

Generally, CT modality is an economical way to generate high-resolution images of human anatomy. CT images show more complex details of bones structures, compared to magnetic resonance imaging (MRI) images. However, one side CT images are degraded by blurring due to many reasons, such as the imperfect resolution of the imaging system, data loss in acquisition, and acquisition noise, to name a few. These artifacts and data loss result in weak contrast and blurry organ boundaries. Furthermore, streak artifact around thick cortical bone results in degraded visibility of some soft tissue tumors present in low contrast regions. Therefore, contrast enhancement for CT images is critical to facilitate evaluating the extent of disease in soft tissue area [1]. Another, source of degraded CT image is the presence of noise, which adds further blur to organ boundaries.

Recently, many CT image deblurring methods have been studied to visualize miniature-sized features. Jiang et al proposed a deblurring method for spiral CT image based on edge signal-to-noise ratio in 2003 [2]. Their method obtained the standard deviationInline graphicof two-dimension Gaussian blur kernel by calculating the minimum value of the edge signal-to-noise ratio of the blurred CT image, and then deblurred the CT image using the EM algorithm. This deblurring method significantly improved the identification of cochlear CT details. In 2005, Wang made an improvement to Jiang's method using the Wiener filter in place of the EM algorithm [3], and accelerated the speed of deblurring algorithm without sacrificing the deblurring effect. Later, based on edge-to-noise ratio and constrained least squares, Zhou proposed a filter blind deblurring algorithm and an iterative blind deblurring algorithm respectively [4]. Both of them significantly improved the image quality, compared with Jiang's and Wang's methods. In 2010, Hussien also used the Wiener filter to restore CT soft tissue [1]. In 2012, Zohair presented a fast deblurring method for CT medical images using a novel kernel set [5].

All the deblurred methods mentioned above only deal with a single CT image without considering the context of image sequence. these methods can also deal with CT image sequences via one by one, which just likes to deblur repeat single image several times with the same operations and the information between adjacent frames are not considered. There may be time-consuming. In this study, we will explore a new image sequence deblurred algorithm by using sparse representation and low-rank decompose model. For the reason that we always obtained CT image sequences from CT medical imaging system and the doctors judge the state of illness according to the changes of the CT image sequence, so we think that dealing with CT image sequence is more significant than dealing with a single CT image. Our method is also suitable for a single CT image, the difference is that we deblur the low-rank component working out the average low-rank image for sequence image but on own rank of a slice CT for single image. The result may slightly worse than using the average rank of image sequence if sequence image have big difference from slices. It is the fact that a single image can use information between adjacent slices. Recently, low-rank technology is used to decompose image sequence into a low-rank component and a sparse component. In low-rank model, noise and blur information is considered to exist in the sparse component of decomposition image, whereas original image information exists in the low-rank component [6]. Following a similar philosophy, CT sequence images can also be decomposed into the sparse and low-rank component, and restoration can be applied to the sparse and low-rank components, respectively. In this paper, a CT sequence image restoration algorithm is proposed based on low-rank decomposition. Three classic low-rank models have been assessed in the experiments; and comparisons were performed on different medical images.

Review

A CT medical imaging system can be modeled as a linear transformation of an incoming analog signal, which is corrupted by intrinsic measurement fluctuations or electronic noise. A blurred image Inline graphicis assumed to be generated by convolving the latent image Inline graphic with a blur kernel Inline graphicwith a latent image, with additive noiseInline graphic:

graphic file with name pone.0072696.e006.jpg (1)

whereInline graphic denotes convolution operator [7][10].

The main cause of degradation in medical CT images is the imperfect resolution of the imaging system, and the degradation function of a two-dimensional medical CT image is generally approximated as an isotropic two-dimensional Gaussian Point Spread Function (PSF) [11]:

graphic file with name pone.0072696.e008.jpg (2)

whereInline graphicis a constant, Inline graphicis the variance.

Image restoration technique aims to recover an image from its observation, degraded with blur and noise. In order to restore the image, prior knowledge of the degradation and inverse filtering must be obtained. Direct inverse filtering is usually used. Unfortunately,it is invalid when noise is taken into consideration. Another, degradation process typically happens in CT medical imaging, which includes blurring caused by imperfect resolution of the imaging system and noise by random fluctuations in signal intensity. Therefore, Wiener filtering [12][14] is a better choice than inverse filtering since it takes noise into consideration for inverse filtering.

We can obtain the expression of the formulaInline graphicin the frequency domain through the discrete Fourier transform:

graphic file with name pone.0072696.e012.jpg (3)

whereInline graphic,Inline graphic,Inline graphic and Inline graphic are the discrete Fourier transform of the latent imageInline graphic, blur kernel Inline graphic, blurred input imageInline graphic and noise Inline graphic respectively. Wiener filtering restoration is a method that regards Inline graphic as its transmission function, and generates the recovery image Inline graphic by minimizing the mean square error between the recovery image Inline graphicand the latent imageInline graphic, namelyInline graphic. The expression of the recovery image by wiener filtering is

graphic file with name pone.0072696.e026.jpg (4)

whereInline graphicdenotes wiener filtering, Inline graphic is the conjugate matrix of Inline graphic,Inline graphic and Inline graphic are the power spectrums of noise and latent image respectively. It is often hard to estimate the values of Inline graphicandInline graphic, and we use the following expression to approximate the wiener filtering restoration.

graphic file with name pone.0072696.e034.jpg (5)

whereInline graphicis a constant, which is numerically takes the reciprocal value of the signal-to-noise ratio of the blur image. The recovery image can be further calculated according to equation Inline graphicby the Fourier inverse transform:Inline graphic.

Our Method

1. Ethics Statement

This study was approved by Key Lab of Intelligent Perception and Image Understanding of Ministry of Education and by the institutional review board (IRB) of The School of Oncology, Peking University (Beijing Cancer Hospital). The doctors obtained signed informed consent forms from all selected patients prior to the routine clinical course of CT examinations.

2. Motivation

Generally, we obtained CT image sequences from CT medical imaging system, but the existing deblurred methods always focus on the single image. In fact, each CT image in the same sequence is similar with its adjacent frames or maybe with a little change. Another, it was shown that a low-rank matrix could be recovered from incomplete sampling of its entries by computing the matrix of minimum nuclear norm the data [15]. Inspired by the image decomposition in Ref. [6] and the video processing, CT image sequences are decomposed by sparse and low-rank here. We can find noise and blur information exist in the sparse component of decomposition image, whereas most of the original image information exists in the low-rank component. Thus, CT sequence images restoration can be operated both in sparse and low-rank components, respectively. Now, sparse and low-rank technology mainly includes three kinds of low-rank decomposition models, and each low-rank model has its emphasis. In this study, both RPCA and GoDec models will be used to deblur CT image sequences. More details can be seen from the following subsections. The frame of our work is shown in Figure 1.

Figure 1. Flow chart of our algorithm.

Figure 1

3. Framework of sparse and low-rank matrix decomposition

Sparse and low-rank decomposition is widely used in background modeling and shadow removal; it usually focuses on image sequences due to their intrinsic sparse characteristics. Medical CT image sequence has strong correlation between adjacent frames, and it is pointed out that medical CT images are sparse [16], Inspired by the image decomposition in natural image deblurring, we applied the sparse and low-rank decomposition for CT image deblurring. In this section, we will briefly introduce the image decomposition with three low-rank models.

Model 1

Inline graphic , whereInline graphicis the data matrix of the original image,Inline graphicis a low-rank matrix, Inline graphicis a sparse matrix.

By using theInline graphic-norm as the proxy of sparsity and the nuclear norm as the surrogate for low-rank, as in statistics and image processing [15]-[18], the sparse and low-rank recovery can be accomplished by solving the following RPCA problem:

graphic file with name pone.0072696.e043.jpg (6)

whereInline graphicis the data matrix of the original image,Inline graphicis the low-rank component ofInline graphic,Inline graphicis the sparse component ofInline graphic, Inline graphicis the Inline graphic-norm defined by the component-wise sum of the absolute values of all entries,Inline graphicis the nuclear norm defined by the sum of singular values, Inline graphicis a positive weighting parameter. This problem arises in many applications, such as image processing, web data ranking, and bioinformatic data analysis. Under surprisingly broad conditions, the RPCA problem can be exactly solved via convex optimization that minimizes a combination of the nuclear norm and the Inline graphic-norm. It has the advantages of high speed and precision. For the RPCA problemInline graphic, we may apply the augmented Lagrange multiplier method by identifying:

graphic file with name pone.0072696.e055.jpg (7)

Then its Lagrangian function [19][22] is:

graphic file with name pone.0072696.e056.jpg (8)

whereInline graphicis the Lagrange multiplier, Inline graphicis a positive scalar, Inline graphicdenotes the standard trace inner product and Inline graphicis the Frobenius norm. Its iterative scheme is:

graphic file with name pone.0072696.e061.jpg (9)

Formula Inline graphiccan be solved by the following:

graphic file with name pone.0072696.e063.jpg (10)

This algorithm solves the RPCA problem through the Lagrange multiplier method, which recovers a low-rank matrix with an unknown fraction of its entries arbitrarily corrupted.

Model 2

Inline graphic, whereInline graphicis the data matrix of the original image, Inline graphicis the skinny SVD, Inline graphicis a sparse matrix.

The decomposition problem based on model 2 can be converted into the following optimization problem:

graphic file with name pone.0072696.e068.jpg (11)

Its augmented Lagrangian function [23][28] can be written as the following equation:

graphic file with name pone.0072696.e069.jpg (12)

where Inline graphic is the Lagrange multiplier, Inline graphicand Inline graphic are linear mappings, Inline graphicand Inline graphicare convex functions,Inline graphicis the penalty parameter, Inline graphic denotes the inner product, Inline graphic is the Frobenius norm. Its iterative scheme is:

graphic file with name pone.0072696.e078.jpg (13)

whereInline graphicis the adjoint ofInline graphic,Inline graphic and Inline graphicare parameters. Penalty parameterInline graphicis updated according to the formula: Inline graphic, whereInline graphicis an upper bound of Inline graphic. The value ofInline graphicis defined as

graphic file with name pone.0072696.e088.jpg (14)

whereInline graphicis a constant.

This is the LADMAP algorithm. It solves the low-rank representation problem through the alternating direction method, and linearizes the quadratic penalty term adaptively. Compared with the traditional alternating direction method, this method has a novel rule to update the penalty so that it converges fast, without the need to introduce auxiliary variables or to invert matrices during the operation process. It has found wide applications in computer vision and machine learning.

Model 3

Inline graphic,Inline graphic, whereInline graphicis the data matrix of the original image,Inline graphicis a low-rank matrix, Inline graphicis a sparse matrix, Inline graphicis a noise matrix, Inline graphicis the rank ofInline graphic, Inline graphicis the candinality. During the decomposition process, the algorithm alternatingly assigns the Inline graphicapproximation ofInline graphictoInline graphicand assigns the sparse approximation with cardinalityInline graphicofInline graphictoInline graphic.

The decomposition problem based on model 3 can be converted into the following optimization problem [29][34]:

graphic file with name pone.0072696.e105.jpg (15)

Formula Inline graphic can be converted into the following two sub-problems:

graphic file with name pone.0072696.e107.jpg (16)

which is equivalent to

graphic file with name pone.0072696.e108.jpg (17)

where Inline graphic,Inline graphic,Inline graphic;Inline graphic, Inline graphic,Inline graphicand Inline graphicare the QR-decomposition of Inline graphicand Inline graphicrespectively.

This is the GoDec algorithm, which is a low-rank approximation method based on bilateral random projections. The algorithm can approximate the low-rank component, the sparse component and the noise component of the input data matrix. It has the advantage of small relative error and high decomposition speed.

To sum up, RPCA and GoDec share similar motivations in that they both explore the low-rank and sparse structures in the given data matrixInline graphic. They differ, however, by their distinctive ways of handling the specific decomposition but they are intrinsically different. RPCA assumesInline graphic (Inline graphicis sparse noise) and exactly decomposesInline graphicintoInline graphicandInline graphicwithout pre-defined rank(Inline graphic) and card(Inline graphic), that is, RPCA offers a blind separation of low-rank data and sparse noise, however, GoDec produces approximated decomposition of a general matrix Inline graphicwhose exact RPCA decomposition does not exist due to the additive noise Inline graphicand pre-defined rank(Inline graphic) and card(Inline graphic); GoDec directly constrains the rank range of Inline graphicand the cardinality range of Inline graphic, while RPCA minimizes their corresponding convex polytopes (i.e., the nuclear norm of Inline graphicand Inline graphic-norm of Inline graphic); GoDec usually produces less relative error with much less CPU seconds than RPCA. And the improvement of accuracy for the model of GoDec is due to more general than that of RPCA by considering the noise component. LADMAP and RPCA are same intrinsically, but LADMAP reduces the auxiliary variables and constraints, further accelerates the convergence speed and improves the accuracy of decomposition.

4. Restoration using low-rank matrix decomposition on CT image sequence

In this paper, sparse and low-rank matrix decomposition was applied to the problem of medical CT image sequence restoration. For the blurred CT image, it is necessary to recover its low-rank component, because it conveys major information on the latent image. The sparse component, on the other hand, normally reflects the majority of blurring. In practice, CT images differ in their characteristics: some contain high level of noise that seriously degrades image quality and affects visualization; in others, the noise level is relatively low and has little impact on the visual quality of the image or diagnosis of the lesions. Therefore, it is necessary for us to select the appropriate low-rank model based on the image characteristics, and to perform low-rank decomposition and restoration in order to obtain the desirable recovery results.

We propose a new CT image sequence restoration model based on low-rank decomposition as follows:

graphic file with name pone.0072696.e135.jpg (18)

whereInline graphicis the Inline graphic slice of the original CT sequence, Inline graphicis a low-rank matrix, Inline graphicis a sparse matrix, Inline graphic is a noise matrix of Inline graphic, Inline graphicis the average of all the low-rank matrix Inline graphic,Inline graphic, Inline graphic are recovery functions, Inline graphicis 0 or 1 according to the low-rank model.

Also, there exist several methods using the information of the adjacent frames, such as the methods introduced in ref. [35], [36], but they use the idea that the corrupted portions of the projection data can be substituted with the corresponding portions from an unaffected adjacent slice, and restore the image one by one. Our method can restore the image sequence by one-time processing, which can not only consider the common characters of the image sequence but also take the different features of each image into account.

In natural imaging, the image blur can be regarded as atmospheric turbulence affecting the observed scene captured by the camera due to fluctuations of the refraction index of the medium [37]. This phenomenon may also exist in the medical CT imaging process caused by the refraction of the human tissue when the X-ray go into the human body, so we propose another degradation function we call turbulence PSF in this paper, which is acted on the sparse component for wiener filtering, the expression is as follows [38]:

graphic file with name pone.0072696.e147.jpg (19)

whereInline graphic is a constant.

This degradation function we provided was inspired by the blurring natural image and then we think the turbulence also exist in CT imaging based on the reference [11]. Furthermore, after CT image sequences are decomposed into sparse and low-rank components, blur information has often concentrated on the sparse component of decomposition image and there is not much difference from low-rank components. Therefore, turbulence PSF is acted on the sparse component as well as Gaussian PSF is used on the average low-rank component. In order to demonstrate the performance of provided degradation function, we did some comparison experiments that we deblur a single CT image with only turbulence PSF, only Gaussian PSF and both the two PSFs, the result shows that use both the PSFs have more advantages.

The detailed steps of our algorithm are as follows:

Algorithm: CT image sequence restoration based on sparse and low-rank decomposition

Input: the blurred CT image sequence

Output: the latent CT image sequence

Step 1: Input the medical CT image sequenceInline graphic. Inline graphicrepresents theInline graphicimage in the sequence Inline graphic,Inline graphic. IfInline graphicis acolor image, convert it to gray scale;

Step 2: Use all the CT images in the sequenceInline graphicto synthesize a high dimensional matrix, each column of the high dimensional matrix represents a single CT imageInline graphic;

Step 3: select a reasonable low-rank model to decompose the high dimensional matrix in step 2 into high dimensional sparse matrix, low-rank matrix and noise matrix according to the actual situation of the CT image sequenceInline graphic;

Step 4: convert the high dimensional sparse matrix, low-rank matrix and noise matrix into sparse image sequenceInline graphic, low-rank image sequenceInline graphicand noise image sequence Inline graphic, respectively;

Step 5: Using our restoration model Inline graphicto restore the blurred CT imageInline graphic, whereInline graphic. Inline graphic,Inline graphicand Inline graphicare theInline graphicimages of image sequenceInline graphic,Inline graphicandInline graphic,respectively. For each slice image, when Gaussian PSF acts on Inline graphic, common knowledge of sequence images is used to restore a low-rank matrix of Inline graphic whereas sparse blurring component uses own Inline graphic matrix to restore by turbulence PSF.

5. Evaluation of Recover

In order to objectively evaluate the performance of the image restoration algorithm, we use standard deviation, image information entropy and image quality measurement function value [39][41] as evaluation indices for comparison in this paper.

The formula of standard deviation is as follows

graphic file with name pone.0072696.e174.jpg (20)

where Inline graphicdenotes the pixel value of location Inline graphicof the recovery image, and the size of the recovery image is Inline graphic.The greater the standard deviation value, the more dispersed the gray level distribution, the greater the image contrast, and the more detailed information.

Information entropy is one of the key indicators to measure how much image information is: the greater the value, the larger the amount of information contained in the image, its expression is

graphic file with name pone.0072696.e178.jpg (21)

where Inline graphicdenotes the probability.

Image quality measurement function value is defined as

graphic file with name pone.0072696.e180.jpg (22)

The greater the image quality measurement function value, the more uniform the gray level distribution, and the better the image quality.

Experiments and Analysis

Based on the methods we described in Section 3, we investigate the most appropriate low-rank models for various types of CT images, differing in their noise levels and properties. Each image in our CT image sequences is 512 by 512 in size, with RGB color, obtained on a Discovery CT750 HD at the Beijing Cancer Hospital. We used Inline graphic in the Gaussian PSF, andInline graphic in the turbulence PSF for our experiments. All methods were implemented in Matlab7.10.0 (R2010a), running on desktop with an Intel Core i3 CPU at 2.20GHz and 2GB memory, employing a 32-bit windows 7 operating system.

A. Comparison of different low-rank models

We first use the chest CT image sequence to evaluate the contrast of different low-rank models. The noise is small on each image of the CT sequence and does not affect the basic visualization. We decompose the input chest CT image sequence into a sparse component and a low-rank component in the RPCA model, and then recover the two components using wiener filtering, we useInline graphicin this experiment, and the decomposition criterion is to keep all the low-rank component as much as possible, the procedure is shown in Figure 2.

Figure 2. Shows restoration procedure of sparse and low-rank decomposition.

Figure 2

From left to right, from top to bottom: the first image of the chest CT image sequence, the sparse component, the low-rank component, the recovery image of the sparse component, the recovery image of the low-rank component and the recovery CT image. We can see that the detailed information and the visual effect of the CT image after restoration are obviously improved.

In order to analyze the scope of application of the three different low-rank models, we applied all decomposition models to the same chest CT image, and restored the chest CT image sequence. To illustrate the effectiveness of the proposed method in recovering the CT image sequence, the 10th original image of the chest CT image sequence and its recovery images in different models are shown in Figure 3. For RPCA and LADMAP, we usedInline graphicandInline graphicrespectively, and for GoDec,Inline graphic.

Figure 3. Shows comparison of restoration effect of three low-rank models in dealing with the noiseless CT images.

Figure 3

From left to right: the 10th original chest CT image, the result of RPCA model, the result of LADMAP model, the result of GoDec model.We can see that for noiseless CT image, our method can get satisfactory results, but ringing effect of the recovery image based on the RPCA model is much smaller than the other two models, its advantage in visual effect especially shown in the component which is circled with red ellipses in the images.

To further compare the recovery effect of the three models, we list in Table 1 the image evaluation index values mentioned above for every image in Figure 3, as is shown.

Table 1. Comparison of evaluation index values of the recovery images of the three models.

SD IE IQMFV
The 10th CT image 49.2172 5.5966 2422.3
RPCA model 55.0057 6.1122 3025.6
LADMAP model 54.4365 6.0759 2963.3
GoDec model 57.1869 6.0368 3270.3

From Table 1, we can see that the recovery images using our method have great improvement in image standard deviation, information entropy, and quality measurement function value, compared with the original chest CT image. Although the image standard deviation and quality measurement function value of GoDec model is much greater, indicating sharper contrast, the recovery image has more serious ringing effect. Therefore, for the medical CT image sequence containing a low level of noise, the RPCA model is preferable to decompose the sequence, resulting in better recovery results.

The same comparative experiments were also performed on a stomach CT image sequence, which has a much larger noise component. The results of comparison are shown in Figure 4 and the corresponding evaluation index values of every image are shown in Table 2. For RPCA and LADMAP, we usedInline graphic and Inline graphicrespectively, and for GoDec, Inline graphic.

Figure 4. Shows comparison of restoration effect of three low-rank models in dealing with the CT images that contain large noise.

Figure 4

From left to right: the 10th original stomach CT image, the result of RPCA model, the result of LADMAP model, the result of GoDec model, we can see our method can do some good effect on the medical CT images which contain large noise, the contrast of the images after restoration enhance obviously and the human organ boundaries are clear, there is more detailed information shown out, but the recovery image based on GoDec model shows less noise than the other two images.

Table 2. Comparison of evaluation index values of the recovery images of the three models.

SD IE IQMFV
The 10th CT image 68.0978 3.9737 4637.3
RPCA model 75.8182 4.7177 5748.4
LADMAP model 75.1148 4.7347 5642.2
GoDec model 76.3726 4.6915 5832.7

From Table 2, we can see the recovery images using our method have a great improvement in image standard deviation, information entropy and quality measurement function value compared with the original CT image. Although the difference among the evaluation index values of the three recovery images is small, the recovered image based on the GoDec model shows less noise than the results from the other two methods. Therefore, for the CT images with large noise, the GoDec model is more preferable to decompose the image sequence.

B. Comparison of different recovery methods

To illustrate the effectiveness of the proposed method, we make several groups of contrast experiments between different methods which are shown in Figure 5. We list the image evaluation index values of every group above in Tables 36.

Figure 5. Shows comparisons of different methods.

Figure 5

From top to bottom: chest CT experiment, lung CT experiment, stomach CT (1) experiment, stomach CT (2) experiment. From left to right in each row: the original image, the recovery image using Wang's method, the recovery image using Hussien's method, the recovery image using our method. It needs to say, we select the RPCA model in chest CT and lung CT, and select the GoDec model in stomach CT. We can see that using our method to restore the medical CT image sequence can obtain satisfactory results, the recovery images can show high contrast, clear detail information and clear organ boundaries which are especially shown in the components circled with red ellipses in the images.

Table 3. Comparison of evaluation index values of the chest CT image.

SD IE IQMFV
Original CT image 50.3358 5.5876 2533.7
Wang's [3] 50.2142 5.2891 2521.5
Hussien's [1] 50.4130 5.7766 2541.5
ours 54.5948 6.0645 2980.6

Table 6. Comparison of evaluation index values of the stomach CT image (2).

SD IE IQMFV
Original CT image 71.1016 4.2681 5055.4
Wang's [3] 71.9176 4.9294 5172.1
Hussien's [1] 71.3398 5.1978 5089.3
ours 78.4211 4.8226 6149.9

Table 4. Comparison of evaluation index values of the lung CT image.

SD IE IQMFV
Original CT image 47.2274 5.5265 2230.4
Wang's [3] 46.7205 5.2103 2182.8
Hussien's [1] 48.6962 5.8733 2371.3
ours 54.3555 6.0751 2954.5

Table 5. Comparison of evaluation index values of the stomach CT image (1).

SD IE IQMFV
Original CT image 71.1016 4.2681 5055.4
Wang's [3] 71.9176 4.9294 5172.1
Hussien's [1] 67.9674 4.9868 4619.5
ours 74.0204 4.6054 5479.0

For the chest CT image comparative experiment, we used varianceInline graphic, noise-to-signal Inline graphicfor Wang's method, and usedInline graphicfor Hussien's method. The decomposition parameter in our method were 0.002,Inline graphic. For the lung CT image comparative experiment, we usedInline graphic, Inline graphicfor Wang's method, and Inline graphic for Hussien's method. In our method, the decomposition parameter were 0.0025,Inline graphic. For the stomach CT image comparative experiment, we used Inline graphic, Inline graphic for Wang's method, and Inline graphic for Hussien's method. In our method, the decomposition parameters were 8.15e4,Inline graphic.

The four groups of comparison of evaluation index values reveal that our method have advantages in all the evaluation index values when deal with the low level noise CT image. But the information entropy values of our method is lower than some of the others in case of high level noise CT images. What we want to clear is that there is no more other effective evaluation index to address this problem so far, So we used information entropy to try it on. Overall, our method is more effective in CT image sequence restoration than the alternative methods.

Conclusion and Prospect

This paper proposed image sequence restoration for CT scan image using Wiener filtering, based on sparse and low-rank decomposition. One of the key points to this method is uniting the CT image restoration under the framework of low-rank models: we first decompose the CT image sequence into sparse component and low-rank component in the RPCA model if noise level is low, and then restore both the two components using wiener filtering; in the presence of high level noise, it is better to select the GoDec model to decompose the images into three components, namely a sparse component, a low-rank component and a noise component, and then restore the sparse component and low-rank component using wiener filtering. It takes about 1.5s for our algorithm to recover a CT image of size 512Inline graphic512. Experiments demonstrated that our method generated better results, compared with the other methods. In terms of medical CT image sequence restoration, our method is highly practical, with clear organ boundary and detailed information in the recovered image. The recovered images also have good soft tissue visibility and image quality. One limitation of our method is the reliance on matrix decomposition: in particular, if the low-rank component of every image in the sequence has a large variation, then our method does not work well. In this paper, both the parameters of the blur kernel and the noise-signal ratio of wiener filtering take empirical values, in the future work, we will seek other paths to determine these parameter values automatically and to explore more accurate blur kernels for the CT images.

Acknowledgments

The authors would like to thank anonymous reviewers for their suggestions as well as Assistant Professor Ruan D providing English writing help who is in the Radiation Oncology Department at University of California, Los Angeles.

Funding Statement

This work was supported in part by the Fundamental Funds for the Center Universities (No. K5051302027), the National Basic Research Program (973 Program) of China (No. 2013CB329402), the fund for Foreign Scholars in University Research and Teaching Programs (the 111 Project) (No. B07048), and the Provincial Natural Science Foundation of Shaanxi of China (No. 2011JQ8020). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

References

  • 1.Hussien MN, IqbalSaripan M (2010) Computed Tomography Soft Tissue Restoration using Wiener Filter. Proceedings of 2010 IEEE Student Conference on Research and Development, 13–14 Dec Putrajaya, Malaysia.
  • 2. Jiang M, Wang G, Skinner MW, Rubinstein JT, Vannier MW (2003) Blind deblurring of Spiral CT image. IEEE Trans. Med. Imaging 22: 251–262. [DOI] [PubMed] [Google Scholar]
  • 3. Wang J, Wang G, Jiang M (2005) Blind deblurring of spiral CT images Based on ENR and Wiener filter. IOS Press Journal of X-Ray Science and Technology 13: 49–60. [Google Scholar]
  • 4.Liu WB (2007) Blind deblurring algorithm of CT image based on edge to noise ratio and constrained least squares [D]. Peking University, BeiJing.
  • 5. Al-Ameen Z, Sulong G, Johar MGM (2012) Fast Deblurring Method for Computed Tomography Medical Images Using a Novel Kernels Set. International Journal of Bio-Science and Bio-Technology 4(3): 9–19. [Google Scholar]
  • 6.Xu YQ, Hu XY, Wang L, Peng S (2012) Single Image Blind Deblurring with Image Decomposition. IEEE, ICASSP.
  • 7. Fazel M, Hindi H, Boyd S (2001) A rank minimization heuristic with application to minimum order system approximation. Proceedings American Control Conference 6: 4734–4739. [Google Scholar]
  • 8. Cai JF, Ji H, Liu CQ, Shen ZW (2012) Framelet based blind motion deblurring from a single image. IEEE Transaction on Image Processing. 21(2): 562–572. [DOI] [PubMed] [Google Scholar]
  • 9. Cai JF, Osher S, Shen ZW (2009) Split Bregman method and frame based image restoration. Multiscale model, Simul 8(2): 337–369. [Google Scholar]
  • 10.Fergus R, Singh B, Hertzmann A, Roweis ST, FreemanWT (2006) Removing camera shake from a single photograph. ACM Transactions on Graphics 25, 787–794.
  • 11. Wen CY, Lee CH (2002) Point spread functions and their applications to forensic image restoration. Forensic Science Journal 1: 15–26. [Google Scholar]
  • 12. Jiang M, Wang G (2003) Development of blind image deconvolution and its applications. J. X-ray Science and Technology 11 (1): 13–19. [PubMed] [Google Scholar]
  • 13.William KP, Faramarz D (1997) Fast computational techniques for Pseudo inverse and Wiener image restoration. 06.
  • 14.Hu XP, Chen GL, Mao ZY (2007) Study on Wiener filtering for restoration of defocus blur image. Chinese Journal of Scientific Instrument. 28(3).
  • 15.Yuan XM, Yang JF (2009) Sparse and low-rank matrix decomposition via alternating direction method. Available: http://math.nju.edu.cn/~jfyang/files/LRSD-09.pdf. Accessed 2013 Aug 12.
  • 16. Xing B, Wang J (2012) Denoising of Medical CT Image Based on Sparse Decomposition. Journal of Biomedical Eng 29(3): 456–459. [PubMed] [Google Scholar]
  • 17. Chen S, Donoho D, Saunders M (2012) tomic decomposition by basis pursuit. SIAM Journal on Scientific Computing 29(3): 456–459. [Google Scholar]
  • 18.Fazel M (2002) rank minimization with applications. PhD thesis, Stanford University.
  • 19.Lin ZC, Chen MM, Ma Y (2011) The Augmented Lagrange Multiplier Method for Exact Recovery of Corrupted Low-Rank Matrices. Available: http://arxiv.org/abs/1009.5055. Accessed 2013 Aug 12.
  • 20.Bertsekas D (1982) Constrained Optimization and Lagrange Multiplier Method. Waltham, MA: Academic Press.
  • 21.Bertsekas D (1999) Non-linear Programming. Nashua, NH: Athena Scientific.
  • 22.Wright J, Peng Y, Ma Y, Ganesh A, Rao S (2009) Robust principal component analysis: Exact recovery of corrupted low-rank matrices via convex optimization. Available: http://perception.csl.illinois.edu/matrix-rank/Files/nips2009.pdf. Accessed 2013 Aug 12.
  • 23.Lin ZC, Liu RS, Su ZX (2011) Linearized Alternating Direction Method with Adaptive Penalty for Low-Rank Representation. NIPS, Optimization and Control.
  • 24.Cai J, Candès E, Shen Z (2008) A singular value thresholding algorithm for matrix completion. Available: http://arxiv.org/abs/0810.3286. Accessed 2013 Aug 12.
  • 25.Lin Z, Chen M, Wu L, Ma Y (2009) The augmented Lagrange multiplier method for exact recovery of corrupted low-rank matrices. UIUC Technical Report UILU-ENG-09-2215; arxiv:1009.5055.
  • 26.Liu G, Lin Z, Yu Y (2010) Robust subspace segmentation by low-rank representation. In Proceedings of the 27th International Conference on Machine Learning, Haifa, Israel.
  • 27. Tao M, Yuan XM (2011) Recovering low-rank and sparse components of matrices from incomplete and noisy observations. SIAM Journal on Optimization 21(1): 57–81. [Google Scholar]
  • 28. Yang J, Yuan X (2011) Linearized augmented Lagrangian and alternating direction methods for nuclear norm minimization. Mathematics of Computation 82: 301–329. [Google Scholar]
  • 29.Zhou TY, Tao DC (2011) GoDec: Randomized Low-rank & Sparse Matrix Decomposition in Noisy Case. Proceedings of the 28th International Conference on Machine Learning, Bellevue, WA, USA.
  • 30. Bredies K, Lorenz, D A (2008) Iterated hard shrinkage for minimization problems with sparsity constraints. SIAM Journal on Scientific Computing 30(2): 657–683. [Google Scholar]
  • 31. Cai J, Candès EJ (2010) ShenZ (2010) A singular value thresholding algorithm for matrix completion. SIAM Journal on Optimization 20(4): 1956–1982. [Google Scholar]
  • 32. Cheng L, Gong M, SchuurmansD, Caelli T (2011) Real-time discriminative background subtraction. IEEE Trans on Image Processing 20(5): 1401–1414. [DOI] [PubMed] [Google Scholar]
  • 33. Donoho DL (2006) Compressed sensing. IEEE Trans. on Information Theory 52(4): 1289–1306. [Google Scholar]
  • 34.Zhou T, Tao D (2011) Bilateral random projection based low-rank approximation. Technical report.
  • 35. Tohnak S, Mehnert AJH, Mahoney M, Crozier S (2011) Dental CT metal reduction based on sequential substitution. Dentomaxillofacial Radiology 40: 184–190. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36. Dong J, Kondo A, Abe K, Hayakawa Y (2011) Successive iterative restoration applied to streak artifact reduction in X-ray CT image of dento-alveolar region. Int J CARS 6: 635–640. [DOI] [PubMed] [Google Scholar]
  • 37.Aftab K, Yin H (2012) Quality Measure for Blind Image Deblurring. Imaging Systems and Techniques (IST), 2012 IEEE International Conference on Date of Conference: 16–17 July 2012.
  • 38. Hufnagel RE, Stanley NR (1964) Modulation Transfer Function Associated with Image Transmission through Turbulent Media. Journal of the Optical Society of America 54(1): 52–61. [Google Scholar]
  • 39. Wang Z, Bovik AC, Ligang L (2002) Why is image quality assessment so difficult? Acoustics, Speech, and Signal Processing,2002 Proceedings 14: IV–3313-IV-3316. [Google Scholar]
  • 40. Zhou JL, Hang Lv (2001) Image enhancement based on a new g0065netical algorithm. Chinese journal of computers 24(9): 959–964. [Google Scholar]
  • 41.Rosenfeld A, Avinash C K (1982) Digital Picture Processing[M]. NewYork:Academic Press. 154–167.