Abstract
An automated hemagglutination-inhibition (HI) test for the “shipping fever” strain (SF-4) of parainfluenza 3 antibody in bovine sera was developed and compared to manual tube and microtiter test procedures. The automated system operating at 60 samples per hr provided the most test results per specified time period, and the manual tube test provided the least. The manual microtiter test and the automated system at 40 samples per hr, falling between the two above procedures, were comparable in the number of sera that could be titrated in 1 day by one technician. There was little difference between automated and manual test reproducibility when measured at the twofold titer one-dilution difference level. However, the automated system titrated a higher number of sera at the same titer on repeat runs than either of the manual test procedures. The automated one-quartile difference reproducibility (each twofold dilution subdivided into 4 units—“quartiles”) was equal to the manual test one-dilution difference reproducibility. The standard deviation of the per cent variation from the mean of paired serum titers for 40-sample-per-hr runs ranged from ±3.49 to ±5.36%. The manual and automated systems were of comparable sensitivity in their detection of negative sera.
Full text
PDF












Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- ABINANTI F. R., HOERLEIN A. B., WATSON R. L., HUEBNER R. J. Serologic studies on myxovirus para-influenza 3 in cattle and the prevalence of antibodies in bovines. J Immunol. 1961 May;86:505–511. [PubMed] [Google Scholar]
- CLARKE D. H., CASALS J. Techniques for hemagglutination and hemagglutination-inhibition with arthropod-borne viruses. Am J Trop Med Hyg. 1958 Sep;7(5):561–573. doi: 10.4269/ajtmh.1958.7.561. [DOI] [PubMed] [Google Scholar]
- Cohen A. Automatic technique for titration of influenza virus haemagglutination inhibitors. J Clin Pathol. 1966 Nov;19(6):589–594. doi: 10.1136/jcp.19.6.589. [DOI] [PMC free article] [PubMed] [Google Scholar]
- DeBellis D. J., Erie G. R., Lawlis J. F. Comparative studies of reagents used in automated CCA testing of influenza virus. Ann N Y Acad Sci. 1968 Nov 15;153(2):582–594. doi: 10.1111/j.1749-6632.1968.tb11771.x. [DOI] [PubMed] [Google Scholar]
- Gaillon R., Ripault J., Studievic C., Dausset J. Use of the Auto-Analyzer to perform serological tests for syphilis. Study of 1,009 sera using a complement fixation test with the cardiolipidic antigen. Int Arch Allergy Appl Immunol. 1967;32(3):278–281. doi: 10.1159/000229937. [DOI] [PubMed] [Google Scholar]
- Grunmeier P. W., Gray A., Ferrari A. Automated hemagglutination assays. Ann N Y Acad Sci. 1965 Nov 9;130(2):809–818. doi: 10.1111/j.1749-6632.1965.tb12624.x. [DOI] [PubMed] [Google Scholar]
- HOERLEIN A. B., MANSFIELD M. E., ABINANTI F. R., HUEBNER R. J. Studies of shipping fever of cattle. I. Para-influenza 3 virus antibodies in feeder calves. J Am Vet Med Assoc. 1959 Aug 1;135(3):153–160. [PubMed] [Google Scholar]
- Hall E. C., Felker M. B. Reproducibility in the serological laboratory. Health Lab Sci. 1970 Apr;7(2):63–68. [PubMed] [Google Scholar]
- Hebeka E. K., Brandon F. B., Molteni J. C. Assay of hemagglutination titer of influenza with the auto analyzer. Appl Microbiol. 1967 Jul;15(4):956–958. doi: 10.1128/am.15.4.956-958.1967. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hebeka E. K., Walker R. M., Beardmore W. B. Automated procedure for measuring antigenicity of extracted and intact influenza virus. Appl Microbiol. 1968 Nov;16(11):1699–1705. doi: 10.1128/am.16.11.1699-1705.1968. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McGrew B. E., Stout G. W., Falcone V. H. Further studies of an automated flocculation test for syphilis. Am J Med Technol. 1968 Nov;34(11):634–643. [PubMed] [Google Scholar]
- Pugh V. W., Gaze R. W. The Reiter protein complement-fixation test using the Auto-Analyzer. J Clin Pathol. 1966 Nov;19(6):595–599. doi: 10.1136/jcp.19.6.595. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Roumiantzeff M., Fayet M. T. Emploi de sérums spécifiques d'éléments viraux dans des réactions de fixation du complément du virus de la fièvre aphteusee. Ann Inst Pasteur (Paris) 1969 Jun;116(6):833–851. [PubMed] [Google Scholar]
- Stevens R. W., Stroebel E. The automated reagin test: results compared with VDRL and FTA-ABS tests. Am J Clin Pathol. 1970 Jan;53(1):32–34. doi: 10.1093/ajcp/53.1.32. [DOI] [PubMed] [Google Scholar]