Skip to main content
Applied Microbiology logoLink to Applied Microbiology
. 1969 Aug;18(2):180–187. doi: 10.1128/am.18.2.180-187.1969

Biological Evaluation of Carpeting

Roger L Anderson 1
PMCID: PMC377940  PMID: 5807156

Abstract

Studies of microbial contamination were carried out on a carpet strip (acrilan) installed in a laboratory corridor and on two carpet strips (acrilan and wool) installed in two rooms in a pediatric hospital. A sampling procedure of randomly removing 8-mm plugs from the carpets was used for subsequent enumeration and identification of contaminating microorganisms. Microbial counts increased with time, reached a “plateau” at about 4 weeks, and appeared to be related to the amount of activity present in the carpeted area. Vacuuming of carpets showed only a slight reduction in the number of recoverable microorganisms. Qualitative studies on a strip of acrilan carpet installed in a hospital room indicated that Staphylococcus epidermidis and gram-positive nonsporeforming rods were the predominating microorganisms. Coagulase-positive S. aureus organisms were isolated during every sampling period, and gram-negative rods were also regularly isolated. Most nitrate-reducing gram-negative rods belonged to the Enterobacter and Escherichia groups. Survival studies conducted on carpet strips after hospital installation showed relatively constant levels of contamination for about 6 weeks, followed by a gradual reduction in numbers; coagulase-positive S. aureus were found for 35 days, whereas the proportions of most organisms remained relatively constant with time.

Full text

PDF
180

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. BEDFORD J., SARDISCO E. CARPET STANDS TEST OF TIME AND TRAFFIC. Mod Hosp. 1964 Feb;102:138–140. [PubMed] [Google Scholar]
  2. BUCKLAND F. E., TYRRELL D. A. Loss of infectivity on drying various viruses. Nature. 1962 Sep 15;195:1063–1064. doi: 10.1038/1951063a0. [DOI] [PubMed] [Google Scholar]
  3. CORMACK D. V., MORRISON H. G. RELATIVE HUMIDITY, INOSITOL AND THE EFFECT OF RADIATIONS ON AIR-DRIED MICRO-ORGANISMS. Nature. 1964 Mar 14;201:1103–1105. doi: 10.1038/2011103a0. [DOI] [PubMed] [Google Scholar]
  4. GRECO J. T. CARPETING VS. RESILIENT FLOORING: A COMPARATIVE STUDY IN A METROPOLITAN HOSPITAL. Hospitals. 1965 Jun 16;39:55–PASSIM. [PubMed] [Google Scholar]
  5. HARPER G. J. Airborne micro-organisms: survival tests with four viruses. J Hyg (Lond) 1961 Dec;59:479–486. doi: 10.1017/s0022172400039176. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. HEMMES J. H., WINKLER K. C., KOOL S. M. Virus survival as a seasonal factor in influenza and polimyelitis. Nature. 1960 Oct 29;188:430–431. doi: 10.1038/188430a0. [DOI] [PubMed] [Google Scholar]
  7. KETHLEY T. W., FINCHER E. L., COWN W. B. The effect of sampling method upon the apparent response of airborne bacteria to temperature and relative humidity. J Infect Dis. 1957 Jan-Feb;100(1):97–102. doi: 10.1093/infdis/100.1.97. [DOI] [PubMed] [Google Scholar]
  8. Shaffer J. G., Key I. The microbiological effects of carpeting on the hospital environment. Hospitals. 1966 Nov 16;40(22):126–139. [PubMed] [Google Scholar]
  9. Shaffer J. G., Key I., Thomas B. High-power vacuum keeps bacteria low in care of carpeting. Mod Hosp. 1966 Oct;107(4):166–174. [PubMed] [Google Scholar]
  10. Shaffer J. G. Microbiology of hospital carpeting. Health Lab Sci. 1966 Apr;3(2):73–85. [PubMed] [Google Scholar]
  11. Snyder J. Carpeting in the modern hospital. Can Hosp. 1966 Apr;43(4):56–58. [PubMed] [Google Scholar]
  12. Songer J. R. Influence of relative humidity on the survival of some airborne viruses. Appl Microbiol. 1967 Jan;15(1):35–42. doi: 10.1128/am.15.1.35-42.1967. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. WEBB S. J. Factors affecting the viability of air-borne bacteria. II. The effect of chemical additives on the behavior of air-borne cells. Can J Microbiol. 1960 Feb;6:71–87. doi: 10.1139/m60-010. [DOI] [PubMed] [Google Scholar]
  14. WEBB S. J. Factors affecting the viability of air-borne bacteria. III. The role of bonded water and protein structure in the death of air-borne cells. Can J Microbiol. 1960 Feb;6:89–105. doi: 10.1139/m60-011. [DOI] [PubMed] [Google Scholar]
  15. Walter W. G., Stober A. Probe method for the microbial sampling of hospital carpets. Health Lab Sci. 1968 Jul;5(3):162–170. [PubMed] [Google Scholar]
  16. de Jong J. C., Winkler K. C. The inactivation of poliovirus in aerosols. J Hyg (Lond) 1968 Dec;66(4):557–565. doi: 10.1017/s0022172400028308. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Applied Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES