Abstract.
Posterior lumbar interbody fusion (PLIF) using threaded cages has gained wide popularity for lumbosacral spinal disease. Our biomechanical tests showed that PLIF using a single diagonal cage with unilateral facetectomy does add a little to spinal stability and provides equal or even higher postoperative stability than PLIF using two posterior cages with bilateral facetectomy. Studies also demonstrated that cages placed using a posterior approach did not cause the same increase in spinal stiffness seen with pedicle screw instrumentation, and we concluded that cages should not be used posteriorly without other forms of fixation. On the other hand, placement of two cages using a posterior approach does have the disadvantage of risk to the bilateral nerve roots. We therefore performed a prospective study to determine whether PLIF can be accomplished by utilizing a single diagonal fusion cage with the application of supplemental transpedicular screw/rod instrumentation. Twenty-seven patients underwent a PLIF using one single fusion cage (BAK, Sulzer Spine-Tech, Minneapolis, MN, USA) inserted posterolaterally and oriented anteromedially on the symptomatic side with unilateral facetectomy and at the same level supplemental fixation with a transpedicular screw/rod system. The internal fixation systems included 12 SOCON spinal systems (Aesculap AG, Germany) and 15 TSRH spinal systems (Medtronic Sofamor Danek, USA). The inclusion criteria were grade 1 to 2 lumbar isthmic spondylolisthesis, lumbar degenerative spondylolisthesis, and recurrent lumbar disc herniations with instability. Patients had at least 1 year of low back pain and/or unilateral sciatica and a severely restricted functional ability in individuals aged 28–55 years. Patients with more than grade 2 spondylolisthesis or adjacent-level degeneration were excluded from the study. Patients were clinically assessed prior to surgery by an independent assessor; they were then reassessed at 1, 3, 6, 12, 18, and 24 months postoperatively by the same assessor and put into four categories: excellent, good, fair, and poor. Operative time, blood loss, hospital expense, and complications were also recorded. All patients achieved successful radiographic fusion at 2 years, and this was achieved at 1 year in 25 out of 27 patients. At 2 years, clinical results were excellent in 15patients, good in 10, fair in 1, and poor in 1. Regarding complications, one patient had a postoperative motor and sensory deficit of the nerve root. Reoperation was required in one patient due to migration of pedicle screws. No implant fractures or deformities occurred in any of the patients. PLIF using diagonal insertion of a single threaded cage with supplemental transpedicular screw/rod instrumentation enables sufficient decompression and solid interbody fusion to be achieved with minimal invasion of the posterior spinal elements. It is a clinically safer, easier, and more economical means of accomplishing PLIF.
Keywords: Lumbar Fusion cage Implant Transpedicular screw Interbody
Full Text
The Full Text of this article is available as a PDF (222.5 KB).
Footnotes
Electronic Publication