Skip to main content
Applied Microbiology logoLink to Applied Microbiology
. 1973 Oct;26(4):478–484. doi: 10.1128/am.26.4.478-484.1973

Microtiter Solid-Phase Radioimmunoassay for Hepatitis B Antigen

Robert H Purcell 1,2, Doris C Wong 1,2, Harvey J Alter 1,2, Paul V Holland 1,2
PMCID: PMC379831  PMID: 4201649

Abstract

A micro-solid-phase radioimmunoassay (micro-SPRIA) for hepatitis B antigen (HB Ag) was developed for use with microtiter serological equipment. Radiolabeled immunoglobulin G was prepared from human and animal sera containing hepatitis B antibody (HB Ab); it was not necessary to isolate specific HB Ab by immunochemical means. A micro-SPRIA prepared with guinea pig reagents was approximately as sensitive as the AusRIA radioimmunoassay, but, like the AusRIA test, yielded false positive results. A micro-SPRIA prepared with human reagents was slightly less sensitive but did not yield false positive results. These micro-SPRIA tests offer several advantages, including conservation of reagents, adaptability to other antigen-antibody systems, ease of performance (especially when testing large numbers of specimens), and economy.

Full text

PDF
478

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Aach R. D., Grisham J. W., Parker C. W. Detection of Australia antigen by radioimmunoassay. Proc Natl Acad Sci U S A. 1971 May;68(5):1056–1060. doi: 10.1073/pnas.68.5.1056. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Almeida J. D., Rubenstein D., Stott E. J. New antigen-antibody system in Australia-antigen-positive hepatitis. Lancet. 1971 Dec 4;2(7736):1225–1227. doi: 10.1016/s0140-6736(71)90543-5. [DOI] [PubMed] [Google Scholar]
  3. Catt K., Tregear G. W. Solid-phase radioimmunoassay in antibody-coated tubes. Science. 1967 Dec 22;158(3808):1570–1572. doi: 10.1126/science.158.3808.1570. [DOI] [PubMed] [Google Scholar]
  4. Coller J. A., Millman I., Halbherr T. C., Blumberg B. S. Radioimmunoprecipitation assay for Australia antigen, antibody, and antigen-antibody complexes. Proc Soc Exp Biol Med. 1971 Oct;138(1):249–257. doi: 10.3181/00379727-138-35872. [DOI] [PubMed] [Google Scholar]
  5. Gerin J. L., Purcell R. H., Hoggan M. D., Holland P. V., Chanock R. M. Biophysical properties of Australia antigen. J Virol. 1969 Nov;4(5):763–768. doi: 10.1128/jvi.4.5.763-768.1969. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. HUNTER W. M., GREENWOOD F. C. Preparation of iodine-131 labelled human growth hormone of high specific activity. Nature. 1962 May 5;194:495–496. doi: 10.1038/194495a0. [DOI] [PubMed] [Google Scholar]
  7. Hollinger F. B., Vorndam V., Dreesman G. R. Assay of Australia antigen and antibody employing double-antibody and solid-phase radioimmunoassay techniques and comparison with the passive hemagglutination methods. J Immunol. 1971 Oct;107(4):1099–1111. [PubMed] [Google Scholar]
  8. Lander J. J., Alter H. J., Purcell R. H. Frequency of antibody to hepatitis-associated antigen as measured by a new radioimmunoassay technique. J Immunol. 1971 May;106(5):1166–1171. [PubMed] [Google Scholar]
  9. Le Bouvier G. L. The heterogeneity of Australia antigen. J Infect Dis. 1971 Jun;123(6):671–675. doi: 10.1093/infdis/123.6.671. [DOI] [PubMed] [Google Scholar]
  10. Ling C. M., Overby L. R. Prevalence of hepatitis B virus antigen as revealed by direct radioimmune assay with 125 I-antibody. J Immunol. 1972 Oct;109(4):834–841. [PubMed] [Google Scholar]
  11. London W. T., Alter H. J., Lander J., Purcell R. H. Serial transmission in rhesus monkeys of an agent related to hepatitis-associated antigen. J Infect Dis. 1972 Apr;125(4):382–389. doi: 10.1093/infdis/125.4.382. [DOI] [PubMed] [Google Scholar]
  12. Prince A. M., Brotman B., Jass D., Ikram H. Specificity of the direct solid-phase radioimmunoassay for detection of hepatitis-B antigen. Lancet. 1973 Jun 16;1(7816):1346–1350. doi: 10.1016/s0140-6736(73)91674-7. [DOI] [PubMed] [Google Scholar]
  13. Purcell R. H., Gerin J. L., Holland P. V., Cline W. L., Chanock R. M. Preparation and characterization of complement-fixing hepatitis-associated antigen and antiserum. J Infect Dis. 1970 Feb;121(2):222–226. doi: 10.1093/infdis/121.2.222. [DOI] [PubMed] [Google Scholar]
  14. Rosenthal J. D., Hayashi K., Notkins A. L. Comparison of direct and indirect solid-phase microradioimmunoassays for the detection of viral antigens and antiviral antibody. Appl Microbiol. 1973 Apr;25(4):567–573. doi: 10.1128/am.25.4.567-573.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Sgouris J. T. Limitations of the radioimmunoassay for hepatitis B antigen (HB Ag). N Engl J Med. 1973 Jan 18;288(3):160–161. doi: 10.1056/NEJM197301182880317. [DOI] [PubMed] [Google Scholar]
  16. Tilden R. L., DeLand F. H. Electroosmophoretic radioimmunoassay: application to hepatitis-associated antigen. J Nucl Med. 1972 Aug;13(8):599–603. [PubMed] [Google Scholar]
  17. Walsh J. H., Yalow R., Berson S. A. Detection of Australia antigen and antibody by means of radioimmunoassay techniques. J Infect Dis. 1970 May;121(5):550–554. doi: 10.1093/infdis/121.5.550. [DOI] [PubMed] [Google Scholar]

Articles from Applied Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES