Abstract
The standardization and quantitation of immunofluorescence with a Farrand microphotometer in the rabies fluorescent-antibody technique were determined. The system is useful in maintaining the quality of examinations for rabies in a public health laboratory since quantitation of reagent, equipment performance, and specificity of reaction can be evaluated. An analysis of the results demonstrates the high degree of reproducibility and the accuracy of the techniques described.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- CLARK H. F., SHEPARD C. C. A DIALYSIS TECHNIQUE FOR PREPARING FLUORESCENT ANTIBODY. Virology. 1963 Aug;20:642–644. doi: 10.1016/0042-6822(63)90292-7. [DOI] [PubMed] [Google Scholar]
- COONS A. H., KAPLAN M. H. Localization of antigen in tissue cells; improvements in a method for the detection of antigen by means of fluorescent antibody. J Exp Med. 1950 Jan 1;91(1):1–13. doi: 10.1084/jem.91.1.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Debbie J. G., Trimarchi C. V. Pantropism of rabies virus in free-ranging rabid red fox Vulpes fulva. J Wildl Dis. 1970 Oct;6(4):500–506. doi: 10.7589/0090-3558-6.4.500. [DOI] [PubMed] [Google Scholar]
- Espmark J. A., Grandien M., Bergquist N. R. Quantitative evaluation of direct and indirect immunofluorescence tests for viral antigens. Ann N Y Acad Sci. 1971 Jun 21;177:98–112. doi: 10.1111/j.1749-6632.1971.tb35036.x. [DOI] [PubMed] [Google Scholar]
- GOLDWASSER R. A., KISSLING R. E. Fluorescent antibody staining of street and fixed rabies virus antigens. Proc Soc Exp Biol Med. 1958 Jun;98(2):219–223. doi: 10.3181/00379727-98-23996. [DOI] [PubMed] [Google Scholar]
- Goldman M. An improved microfluorimeter for measuring brightness of fluorescent antibody reactions. J Histochem Cytochem. 1967 Jan;15(1):38–45. doi: 10.1177/15.1.38. [DOI] [PubMed] [Google Scholar]
- Irvine W. J., Chan M. M., Williamson W. G. The application of microphotometry to the indirect immunofluorescent antibody technique using the human gastric parietal cell antigen-antibody system. Clin Exp Immunol. 1969 May;4(5):607–617. [PMC free article] [PubMed] [Google Scholar]
- Nairn R. C., Herzog F., Ward H. A., De Boer W. G. Microphotometry in immunofluorescence. Clin Exp Immunol. 1969 Jun;4(6):697–705. [PMC free article] [PubMed] [Google Scholar]
- Pittman B., Herbert G. A., Cherry W. B., Taylor G. C. The quantitation of nonspecific staining as a guide for improvement of fluorescent antibody conjugates. J Immunol. 1967 Jun;98(6):1196–1203. [PubMed] [Google Scholar]
- SOKOL F., HULKA A., ALBRECHT P. Fluorescent antibody method. Folia Microbiol (Praha) 1962 May;7:155–161. doi: 10.1007/BF02928236. [DOI] [PubMed] [Google Scholar]
