Abstract
A method is described for determining the number of bacteria in a solution by the use of a machine which deposits a known volume of sample on a rotating agar plate in an ever decreasing amount in the form of an Archimedes spiral. After the sample is incubated, different colony densities are apparent on the surface of the plate. A modified counting grid is described which relates area of the plate of volume of sample. By counting an appropriate area of the plate, the number of bacteria in the sample is estimated. This method was compared to the pour plate procedure with the use of pure and mixed cultures in water and milk. The results did not demonstrate a significant difference in variance between duplicates at the α = 0.01 level when concentrations of 600 to 12 × 105 bacteria per ml were used, but the spiral plate method gave counts that were higher than counts obtained by the pour plate method. The time and materials required for this method are substantially less than those required for the conventional aerobic pour plate procedure.
Full text
PDF








Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bowman R. L., Blume P., Vurek G. G. Capillary-tube scanner for mechanized microbiology. A photoelectric scanner measures growth in agar-filled capillaries and gives a new approach to microbiology. Science. 1967 Oct 6;158(3797):78–83. doi: 10.1126/science.158.3797.78. [DOI] [PubMed] [Google Scholar]
- Clark D. S. Comparison of pour and surface plate methods for determination of bacterial counts. Can J Microbiol. 1967 Nov;13(11):1409–1412. doi: 10.1139/m67-187. [DOI] [PubMed] [Google Scholar]
- DeLand F. H., Wagner H. N., Jr Early detection of bacterial growth, with carbon-14-labeled glucose. Radiology. 1969 Jan;92(1):154–155. doi: 10.1148/92.1.154. [DOI] [PubMed] [Google Scholar]
- MANSBERG H. P. Automatic particle and bacterial colony counter. Science. 1957 Oct 25;126(3278):823–827. doi: 10.1126/science.126.3278.823. [DOI] [PubMed] [Google Scholar]
- Mitz M. A. The detection of bacteria and viruses in liquids. Ann N Y Acad Sci. 1969 Jun 20;158(3):651–664. doi: 10.1111/j.1749-6632.1969.tb56187.x. [DOI] [PubMed] [Google Scholar]
- NELSON S. S., BOLDUAN O. E., SHURCLIFF W. A. The partichrome analyzer for the detection and enumeration of bacteria. Ann N Y Acad Sci. 1962 Jun 29;99:290–297. doi: 10.1111/j.1749-6632.1962.tb45314.x. [DOI] [PubMed] [Google Scholar]
- Read R. B., Jr, Reyes A. L. Variation in plating efficiency of Salmonellae on eight lots of brilliant green agar. Appl Microbiol. 1968 May;16(5):746–748. doi: 10.1128/am.16.5.746-748.1968. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Trotman R. E. The automatic spreading of bacterial culture over a solid agar plate. J Appl Bacteriol. 1971 Sep;34(3):615–616. doi: 10.1111/j.1365-2672.1971.tb02324.x. [DOI] [PubMed] [Google Scholar]
- VAN Soestbergen A. A., Lee C. H. Pour plates or streak plates? Appl Microbiol. 1969 Dec;18(6):1092–1093. doi: 10.1128/am.18.6.1092-1093.1969. [DOI] [PMC free article] [PubMed] [Google Scholar]