Abstract
Blood–brain barrier damage, which can be quantified by measuring vascular permeability, is a potential predictor for hemorrhagic transformation in acute ischemic stroke. Permeability is commonly estimated by applying Patlak analysis to computed tomography (CT) perfusion data, but this method lacks precision. Applying more elaborate kinetic models by means of nonlinear regression (NLR) may improve precision, but is more time consuming and therefore less appropriate in an acute stroke setting. We propose a simplified NLR method that may be faster and still precise enough for clinical use. The aim of this study is to evaluate the reliability of in total 12 variations of Patlak analysis and NLR methods, including the simplified NLR method. Confidence intervals for the permeability estimates were evaluated using simulated CT attenuation–time curves with realistic noise, and clinical data from 20 patients. Although fixating the blood volume improved Patlak analysis, the NLR methods yielded significantly more reliable estimates, but took up to 12 × longer to calculate. The simplified NLR method was ∼4 × faster than other NLR methods, while maintaining the same confidence intervals (CIs). In conclusion, the simplified NLR method is a new, reliable way to estimate permeability in stroke, fast enough for clinical application in an acute stroke setting.
Keywords: CT perfusion, DCE-CT imaging, nonlinear regression, Patlak plot, permeability
Introduction
Computed tomography (CT) perfusion (CTP) imaging, or dynamic contrast enhanced CT, is frequently used for the evaluation of acute stroke.
It has previously been hypothesized that blood–brain barrier damage is a predictor for hemorrhagic transformation in acute stroke.1, 2, 3 With CTP imaging, blood–brain barrier damage can be quantified by measuring vascular permeability. Along with other perfusion parameters, including cerebral blood volume (CBV) and flow (CBF), vascular permeability is a tissue property that can be estimated by comparing tissue attenuation–time curves with the curve of a reference artery or arterial input function (AIF). While CBF and CBV can be measured by imaging the first-pass bolus passage, leakage of contrast agent to the extravascular space is a slower process, only discernible in a delayed phase, and therefore requiring longer scan times. In stroke imaging, permeability is most frequently estimated using linearized regression, that is, by graphical analysis of a Patlak plot.1, 3, 4, 5, 6 This technique transforms the data in the attenuation–time curves so that, in case of irreversible leakage, the data points lie on a straight line when the capillary tracer concentration reaches steady state. The permeability transfer constant Ktrans is the slope of this line, and the relative blood volume is the intersection with the y axis. Patlak analysis is used in, e.g., Extended Brilliance Workspace 4.5 (Philips Healthcare, Best, The Netherlands), syngo Volume Perfusion-CT Neuro 2010 (Siemens Healthcare, Erlangen, Germany), and Vitrea fX 6.4 (Toshiba Medical Systems, Otawara-shi, Japan).
The Patlak method is preferred in the acute stroke setting, because it is fast, despite some inherent drawbacks. First, due to the linearized regression, only the steady-state data points, that is, the last part of the scan, can be used. The estimated values are therefore dependent on the definition of the onset of this steady state, and potentially useful information in the first part of the signal is disregarded. Second, linear least-squares regression assumes that the errors on the samples are normally distributed. For linearized data, this is not the case and therefore the result will not be an optimal least-squares fit.7 Third, other parameters, such as the CBV and CBF, are estimated using a different method, which usually includes Gaussian or gamma variate curve fits, or a regularized inverse filter.8 Because two different methods are used for estimating parameters that essentially describe the same tissue model, the results may disagree. For example, the CBV, which should measure the intravascular volume only, may be overestimated by methods that do not take into account the additional extravascular distribution volume due to increased permeability of the blood–brain barrier.9, 10
As an alternative to the Patlak method, the use of a tissue perfusion model applied with nonlinear regression (NLR) uses the full length of the attenuation–time curves, does not transform the measurement errors, and allows for a simultaneous measurement of all perfusion parameters. For these reasons, NLR methods may provide a superior alternative to the use of Patlak plots in stroke imaging.2, 11, 12 However, NLR methods rely on iterative algorithms that are relatively time consuming. A rapid diagnosis is crucial for treatment of acute stroke; and therefore, these methods may not be practical in an acute stroke setting.
The purpose of this study was to compare the reliability and computation time of permeability estimation using various implementations of the Patlak method and NLR methods using clinical and simulated data. In addition, a novel simplified NLR method is proposed as a faster potential alternative to existing NLR methods.
Materials and methods
This section first describes a first-pass bolus model that is required for the calculation of some of the Patlak methods. Second, details are provided for the theory and technical implementation of different Patlak and NLR methods. Third, a novel method for NLR, based on the adiabatic approximation to the tissue homogeneity (TH) (AATH) model,13 is introduced. Table 1 summarizes all in this study included methods for estimating permeability. Finally, methods for evaluating the models' reliability of estimating Ktrans in both simulated data and clinical CTP scans are presented.
Table 1. An overview of the studied methods and their free and fixed parameters, according to Equation 5.
Method | Free parameters | Vi | tm | Ktrans | Ve | tΔ |
---|---|---|---|---|---|---|
Patlak | 2 | ✓ | 0 | ✓ | ∞ | 0 |
Patlak+delay | 3 | ✓ | 0 | ✓ | ∞ | ✓a |
Patlak fixed | 2 | ✓a | 0 | ✓ | ∞ | 0 |
Patlak fixed+delay | 3 | ✓a | 0 | ✓ | ∞ | ✓a |
AATH | 4 | ✓ | ✓ | ✓ | ✓ | 0 |
AATH+delay | 5 | ✓ | ✓ | ✓ | ✓ | ✓ |
NLR | 3 | ✓ | ✓ | ✓ | ∞ | 0 |
NLR+delay | 4 | ✓ | ✓ | ✓ | ∞ | ✓ |
NLR+Ve | 4 | ✓ | ✓ | ✓ | ✓ | 0 |
NLR+Ve+delay | 5 | ✓ | ✓ | ✓ | ✓ | ✓ |
Simpl. NLR | 3 | ✓ | ✓ | ✓ | ∞ | 0 |
Simpl. NLR+delay | 4 | ✓ | ✓ | ✓ | ∞ | ✓ |
Abbreviations: AATH, adiabatic approximation to the tissue homogeneity; NLR, nonlinear regression.
tm, 0 means that the method does not account for a transit time, Ve, ∞ assumes irreversible leakage, and tΔ, 0 indicates a delay-sensitive method.
Estimated using gamma variate curve fitting.
First-Pass Bolus Fitting
Some implementations of the Patlak plot (described below) require estimates of the CBV and time-to-peak (TTP). To obtain these values, and estimates for the CBF and mean transit time (MTT), the attenuation–time curves can be analyzed using a broad range of methods. Despite that more sophisticated methods exist for estimating the CBF and MTT, this study uses gamma variate curve fitting of the first-pass bolus for obtaining the CBV and TTP, because the variability in outcome between the methods for estimating these parameters was found to be very small.8
A gamma variate fit gives a robust estimate of the area under the curve (AUC) and TTP of the first-pass bolus in the attenuation–time curve.14, 15, 16 Subsequently, the CBV can be estimated by dividing the AUC of the tissue curve by the AUC of the AIF.10 The bolus arrival time (BAT), which is in this study used to define the start of contrast enhancement, is defined as the 0.05% quantile of the gamma variate fit (Figure 1B).
Patlak Linearized Regression
An underlying assumption of Patlak analysis is that the vascular leakage is irreversible during the acquisition time. In that case, the total tracer concentration in the tissue, Ct(t), can be described as a function of the capillary concentration Cc(t), the intravascular blood volume Vi, and a transfer constant Ktrans that represents the flow from the intravascular to the extravascular space:
If both sides of the equation are divided by Cc(t), then a parametric relationship is found that should be linear when the capillary concentration reaches a steady state:
Equation 1 shows that when a linear fit y(t)=ax(t)+b is applied to the Patlak plot of the delayed phase3 of the attenuation–time curves, the slope of the fit (a) and its intersection with the y axis (b) give an estimation of the transfer constant Ktrans and the blood volume Vi, respectively.
The onset of the delayed phase, in which steady state is reached, is in this study empirically defined as the arterial TTP plus 3.5 × the standard deviation of the first-pass bolus, measured using a gamma variate curve fit as described above. This is a reliable method, because gamma variate fits give a robust estimate of the width and position of the first-pass bolus peak.
Patlak Analysis with a Fixed Offset
The blood volume can be read from the Patlak plot (Equation 1). Alternatively, if an estimate of Vi is available from, e.g., first-pass bolus analysis, then Ktrans can be estimated more robustly, using the prior estimated CBV as a fixed offset.17
For comparison, both the ‘standard' and the ‘fixed' Patlak methods are examined (Table 1).
Patlak Analysis with Delay Correction
In CTP imaging, the arterial concentration Ca(t) rather than the capillary concentration Cc(t) is measured to solve Equation 1. In comparison with Ca(t), the average capillary tracer concentration can be affected by an arterial delay and the transit time in the tissue. Schneider et al18 suggested correcting for such a delay by incorporating the difference in TTP between the tissue curve and the AIF, dTTP, taken from gamma variate curve fits to the first-pass bolus, into Equation 1:
In line with this, both the ‘standard' and ‘fixed' Patlak methods are also extended with a delay correction (Table 1). The gamma variate fits to the AIF and tissue curves provide a robust estimate of the TTP values if the leakage is small.
Nonlinear Regression
A Perfusion Model for Nonlinear Regression
Tissue perfusion is frequently modeled as a linear time-invariant system. Under that assumption the dynamics of the tracer concentration in the tissue can be described as the convolution of the AIF with a characteristic impulse response function (IRF). An IRF can be thought of the attenuation–time curve of a small tissue volume in response to an infinitesimal short AIF.
The NLR technique in this study uses a mathematical tissue response model to describe the IRF. The convolution of the measured AIF with a computed IRF gives an estimate of the true attenuation–time curve of the tissue volume. Non-linear regression is used to iteratively adapt any of the parameters in the mathematical model, such as the blood volume and transit time, to minimize the error between this estimate and the measured attenuation–time curve.
Sawada et al19 and Sourbron and Buckley12 found that the detailed TH model, describing the blood flow using a complex set of differential equations,20 fitted the physiology of the brain the best, because of the high density and tortuous nature of the brain capillary network. The full TH model, however, lacks a closed-form time domain solution. Lawrence and Lee13 noticed that, because the contrast agent concentration in the extravascular space changes slowly relative to that in the intravascular space, the IRF of the TH model can be very well approximated by a box function followed by an exponential decay. In this AATH, a box function with a width of tt seconds (the transit time) represents the vascular phase, and an exponential decay represents the parenchymal tissue phase:
In Equation 2, U(t) is the unit step function, F is the plasma flow, and Ve is the extravascular distribution volume. Note that the intravascular distribution volume Vi (the CBV) equals tt × F. Because this model gives estimates for tt and F as opposed to models that only estimate Vi, this type of model is often referred to as a ‘distributed parameter' model, in contrast to ‘lumped parameter' models like the extended Tofts model.21
The AATH model describes the tracer concentration dynamics in a small volume containing a single capillary vessel with a uniform (plug) flow. In reality, however, brain tissue is heterogeneous and even a small volume contains capillaries with variable lengths. This heterogeneity causes a small tissue volume to have a distribution of transit times P(tt;tm), rather than one unique transit time tt. tm is known as the mean transit time, or MTT. When this distribution is taken into account, the full model that is used in this study becomes:
In this equation, QAATH(t;tt) is the IRF of the AATH model for a unique transit time tt and P(tt;tm) is the probability distribution of transit times for tm.
Bredno et al22 found, using highly detailed simulations, that an exponential decay with a delay of a × tm is a good approximation for P(tt;tm) in case a=0.632. The equation for this distribution can be written as:
Solving the model assumes knowledge about the capillary concentration. In practice, due to resolution and noise limits, the AIF is measured in a large artery, often located away from the tissue of interest, so extra travel time for the contrast to arrive in the tissue needs to be accounted for. This is particularly important in the study of tissue regions that are fed through collateral routes. It has been shown that the performance of other deconvolution methods is improved by making them delay insensitive.23, 24 This can be performed by introducing an additional parameter for the delay, tΔ. In the rare case that a collateral artery is chosen for the AIF, tΔ could even be negative at the contralateral side. By substituting Equations 2 and 4 into Equation 3, and introducing tΔ, the following solution is obtained:
The parameter E (0⩽E⩽1) in this equation is the fraction of the flow that leaks into the extravascular space, i.e., Ktrans equals E × F.
The AATH model (Equation 2), and also the tracer kinetic models used by Larson et al,25 are subclasses of Q(t) in which a approximates 1 and tΔ=0. The extended Tofts model, frequently used in the analysis of dynamic contrast enhanced magnetic resonance images, reduces complexity by combining the flow and transit time into a single variable for the blood volume (a lumped parameter), requiring that tm approximates 0 and tΔ=0. The IRF for the standard Patlak model,4 i.e., assuming irreversible leakage, would require that tm approximates 0, tΔ=0 and Ve=∞.
Simplified Nonlinear Regression
Nonlinear regression with five unknown variables is a computational intensive task. Bottlenecks involve the calculation of exponentials, divisions, and a convolution operation in each iteration.
However, the computational complexity is highly reduced by two simplifications to Q(t). Assuming that a approximates 1 and Ve=∞, the two exponentials can be reduced to0 and 1, respectively, and Q(t) can be written as the sum of two step functions:
What is even more important, is that it is now no longer necessary to apply a convolution in each iteration. The convolution of Ca(t) (the AIF) with a shifted unit step function U(t−tΔ) equals:
The integral of Ca(t) just needs to be calculated once, and the convolution of the Ca(t) with QS(t) can be reduced to two interpolations into this integral, at t-tΔ and t-tΔ-tt, respectively.
This simplified version of Q(t) can be used to give estimates of tm (or MTT), F, Ktrans, and tΔ that would be found if the full model was used. These estimates are also used as initial parameters to initialize fitting the full model.
Model Variations
A total of 12 different methods were compared. Both Patlak and the NLR methods include parameters that are either free for estimation or fixed to a predefined value. The full tissue response model Q(t) (Equation 5) has five perfusion parameters, Vi, tm, Ktrans, Ve, and tΔ. Table 1 gives an overview of all methods and parameters. The initial values for NLR were Vi=4 mL/100 g, tm=4 seconds, Ktrans=1.5 mL/min per 100 g, Ve=20 mL/100 g, and tΔ=1 second, and the initial step sizes were2 mL/100 g, 5 seconds, 1.5 mL/min per 100 g, 25 mL/100 g, and 2 seconds, respectively. The initial parameters for the full NLR model are optimized by first applying the simplified NLR model. For all NLR methods, a generic Nelder-Mead downhill simplex method26, 27 with linear constraints was used for optimization.
If global optima are found, which is not guaranteed, then increasing the number of free parameters will result in a better fit (a higher R2), but as a counter-effect it may decrease the reliability of the estimated values. In other words, adding complexity to a model may not necessarily improve the results.
All methods were implemented in a similar manner in C routines that are accessible in Matlab (version 2011b, The MathWorks Inc., Natick, MA, USA) through the Matlab MEX programming interface.
Simulations were applied to gain insight in the response of the models to noise and varying perfusion parameters, and CT brain perfusion scans were analyzed to estimate the reliability of the measured permeability in clinical practice.
Simulated Data
To evaluate in a setting with controlled noise levels and perfusion parameters, tissue attenuation–time curves were simulated by convolving a measured AIF with a generated IRF, and adding Gaussian noise. An AIF (Figure 1A) was extracted from a clinical CTP brain scan as described below.
The AATH model20, 13 (Equation 2) was used to generate the IRFs, because the TH model is thought to match the physiology of the brain better than other published models.19, 12 The blood flow F was kept constant at a rate of 15 mL/min per 100 g, which is comparable to an ischemic penumbra,28 and the leakage was assumed to be irreversible.
The noise level, Ktrans, tm, and delay were varied between the simulations. Four sets of simulations were made. The first is a series of Monte Carlo simulations in which the Ktrans was randomized between 0 and 2 mL/min per 100 g, the tm between 4 and 20 seconds, and the delay between 0 and 5 seconds. In all, 1,000 random simulations were made at noise levels of 0.5, 1.0, and 2.0 Hounsfield units (HU) (s.d.).
In the remaining three sets, one out of three parameters was varied while the others were fixed to 1 HU for the noise level, 0.5 mL/min per 100 g for the Ktrans, 12 seconds for the tm. The delay was fixed to 0 second. In the second set, only the standard deviation of the noise was varied between 0 and 2 HU, in the third set only the Ktrans was varied between 0 and 2 mL/min per 100 g, and in the fourth set only tm was varied between 4 and 20 seconds.
The simulated attenuation curves were analyzed using all methods listed in Table 1, while keeping track of the mean, standard error, and average approximate standard error of the estimated Ktrans values.
Figures 1A, 1C, and 1D give an overview of the measured AIF, and the default IRF, and attenuation–time curve. Both the IRF and the AIF were band limited using a Bartlett kernel (triangular) with a full width at half maximum of 4 seconds. Figures 1E and 1F show how the shape of Q(t) (Equation 5) and the resulting attenuation curves change with different parameters.
Computed Tomography Brain Perfusion Scans
Data Acquisition
The CTP scans of 20 acute ischemic stroke patients that participated in the Dutch Acute Stroke Trial (NCT00880113) were included (chronological order). Dutch Acute Stroke Trial is large prospective multicenter observational cohort study, approved by the institutional medical ethics committee (METC), and in accordance with the Good Clinical Practice guidelines as provided by the International Conference on Harmonisation (ICH-GCP) and Dutch act on medical research involving human subjects (WMO).
For CTP, 40 mL of nonionic contrast agent (Iopromide, Ultravist, 300 mg/mL iodine; Bayer HealthCare Pharmaceuticals, Berlin, Germany) was injected intravenously at a rate of 6 mL/s followed by a 40-mL saline flush at a rate of 6 mL/s. The scans were acquired using a Philips Brilliance iCT scanner (Philips Healthcare) at 80 kVp and 150 mAs/rot and a field-of-view of ∼200 × 200 mm2 with an axial coverage of 65 mm at most. The total acquisition time was 210 seconds, divided into 25 frames with a 2-second interval, followed by 6 frames with a 30-second interval (Figure 1A). The scans were reconstructed in a 512 × 512 matrix with filtered backprojection and a Philips UB filter.
Preprocessing
The open source registration toolbox Elastix29 was used to register the original, 3D high-resolution CTP data (voxel size 0.39 × 0.39 × 0.83 mm3) to the first time frame. Next, slabs of six adjacent registered slices were averaged to obtain 8 to 13 slabs of 5 mm per volume.
Noise reduction is crucial in CTP analysis. Because of the limited radiation dose, the unfiltered scans have a very low signal-to-noise ratio, especially in the areas with low perfusion where blood–brain barrier damage is to be expected. Sophisticated noise filtering, where e.g. temporal information is used to adapt the filter kernel to its spatial neighborhood, is therefore desirable.
A temporal Gaussian filter with a standard deviation of 4 seconds, followed by a 3D bilateral filter (the time-intensity profile similarity filter, or TIPS)30 with a spatial standard deviation (σd) of 4 mm and a profile-similarity standard deviation (σζ) of 50 HU2 were applied to reduce the noise with a minimum loss of resolution.
Arterial Input Function
The AIF was semiautomatically selected either in an internal carotid or in the basilar artery by drawing a circular region of interest in which the attenuation curve with the highest enhancement was chosen. To correct the AUC of the AIF for partial volume effect, a venous output function was in the same way semiautomatically selected in a great sinus perpendicular to the slices,31 which is in line with the clinical scan protocol. A gamma variate curve was fitted to both the AIF and venous output function to estimate their AUCs, the arterial BAT, and the steady-state concentration time (see First-Pass Bolus Fitting section).
Postprocessing
Only the voxels that were classified as penumbra (tissue at risk) were used for statistical analysis. This was performed because the signal-to-noise ratio of the attenuation–time curves in the infarct (irreversible ischemia) is low, which might hamper reliable measurements. The Ktrans in the remainder of the brain (healthy tissue) should in theory be nearly zero.
To extract the penumbra and exclude vessels, tissue types in the brain were segmented based on the CT values in the first frames of the filtered scan, before the BAT. By removing voxels with a CT value of <17 HU or >55 HU (unenhanced), air, fat, and bone are excluded from the analysis, while gray and white matter remain. Within the brain tissue, the infarct and penumbra were defined based on the CBV and relative MTT that were estimated by the simplified NLR method.
To calculate the relative MTT, a symmetry plane was manually drawn to separate the hemispheres. The original MTT map is mirrored over this plane and blurred by a 3D Gaussian kernel with a standard deviation of 3 mm. The relative MTT values are found by dividing the original MTT map by the mirrored, blurred map.
Wintermark et al32 found that the CBV most accurately describes the infarct, with an optimal threshold of 2.0 mL/100 g, and that the relative MTT most accurately describes the penumbra, with an optimal threshold of 145% and the infarct excluded. A CBV threshold of 9 mL/100 g was used to exclude vessels.
A correction factor kH=(1−HLV)/(1−HSV) was applied to correct the tracer concentration for the difference between the hematocrit in large vessels (AIF) and small vessels (arterioles and capillaries).10 The values used for HLV and HSV are 0.45 and 0.25, respectively.33 This correction affects all perfusion parameters that scale with the plasma concentration, i.e., the CBV, CBF, Ktrans, and Ve.
Statistical Analysis
Besides the Ktrans estimate itself, the approximate standard error on the estimated Ktrans for each method was calculated in all voxels. In all, 95% confidence intervals (CIs) were calculated by applying Student's t-distribution to these standard errors. Average CIs are more suitable for estimating the reliability than the standard deviation for two reasons. First, the standard deviation might represent a true variability instead of an error, which is what we like to measure. Second, the standard deviation might be biased due to constraints to the estimated parameter, i.e., Ktrans cannot be negative, nor can it be larger than the flow.
The estimated values and CIs in the penumbra regions were averaged per patient and a Wilcoxon signed-rank test was applied to each pair of methods to test if the differences between the methods were significant (P<0.001).
Results
Simulated Data
Figure 2A shows the standard error on the Ktrans estimates in the Monte Carlo simulations for each method and at different noise levels. Figures 2B to 2G show graphs of the average Ktrans estimates and CIs versus the varied input parameters (noise level, Ktrans, and tm). A narrower CI indicates a more reliable estimate. The results for the six delay corrected methods (Table 1) were very similar to the uncorrected methods, and for that reason the results for the delay corrected methods are not shown to make the graphs more readable. The NLR and simplified NLR methods showed very similar results, which caused these lines to overlap in all of the plots.
Because the steady-state time was defined as the TTP plus 3.5 × the standard deviation of the first-pass bolus, 9 time frames were included for Patlak analysis.
The results showed that noise gives a positive bias to the average Ktrans estimates (Figure 2B), affecting the standard Patlak, AATH, and NLR+Ve the most. Figure 2D shows that, at the default noise level of 1.0 HU, all methods had a positive bias for small Ktrans values, while the methods that assume irreversible leakage (Ve=∞) gave unbiased estimates for larger Ktrans values. The bias for the methods that assume reversible leakage (AATH and NLR+Ve) is also reflected in the high standard errors in Figure 2A. Figure 2F shows that the average Ktrans is not affected by the MTT for transit times shorter than 12 seconds. For long transit times, the AATH and NLR+Ve methods overestimated the Ktrans, while the standard Patlak method returned underestimated Ktrans values.
In all cases with noise, the NLR methods with irreversible leakage were found to have the smallest CIs, while the standard Patlak method had the largest CI, implying that it is least reliable (Figures 2C, 2E, and 2G). All methods gave estimates of which the width of the CI scaled linearly with the noise level (Figure 2C). Figure 2E shows that the confidence of the estimation did not scale with the Ktrans for the methods that assume irreversible leakage (Ve=∞). The methods that assume reversible leakage, AATH and NLR+Ve, showed an increased CI for Ktrans values in the order of 1 mL/min per 100 g. For Ktrans values higher than 2 mL/min per 100 g (not shown in the graph), however, the CI of these methods decreases again to reach a steady state of 0.4 mL/min per 100 g at a Ktrans of 10 mL/min per 100 g, while CIs of the other methods are unaffected. In line with Figure 2F, Figure 2G shows that the average CI was not affected by the MTT for transit times shorter than 12 seconds. For long transit times, the AATH, NLR+Ve, and standard Patlak methods showed an increased CI.
Computed Tomography Brain Perfusion Scans
The Ktrans and CI maps for Ktrans were generated for 20 CTP scans (Figure 3).
There was a large variance in Ktrans and CI between the patients (Table 2), but the Wilcoxon signed-rank tests (Table 3) showed that the average CIs were significantly different between most methods that assume irreversible leakage.
Table 2. The K trans values and 95% confidence intervals (mL/min per 100 g) in the clinical data and in the simulations (default parameters).
Avg. Ktrans |
Avg. 95% CI width |
|||
---|---|---|---|---|
Method | Clinical data | Simulation | Clinical data | Simulation |
Simpl. NLR | 0.39±0.23 | 0.59 | 0.82±0.29 | 0.67 |
Simpl. NLR+delay | 0.36±0.21 | 0.57 | 0.82±0.29 | 0.66 |
NLR | 0.34±0.21 | 0.53 | 0.85±0.31 | 0.69 |
NLR+delay | 0.33±0.19 | 0.53 | 0.85±0.32 | 0.67 |
Patlak fixed | 0.43±0.33 | 0.57 | 1.42±0.49 | 0.93 |
Patlak fixed+delay | 0.45±0.35 | 0.58 | 1.53±0.56 | 1.03 |
AATH | 0.87±0.89 | 1.40 | 1.95±0.94 | 1.50 |
NLR+Ve+delay | 0.72±0.73 | 0.85 | 1.97±1.06 | 1.25 |
AATH+delay | 0.83±0.88 | 0.95 | 2.04±1.07 | 1.21 |
NLR+Ve | 0.77±0.77 | 1.10 | 2.18±1.20 | 1.46 |
Patlak | 0.73±0.45 | 0.69 | 2.65±1.33 | 2.11 |
Patlak+delay | 0.78±0.48 | 0.96 | 2.78±1.45 | 2.10 |
Abbreviations: AATH, adiabatic approximation to the tissue homogeneity; CI, confidence interval; NLR, nonlinear regression; Ve, extravascular distribution volume.
The values are ordered to the width of the confidence interval in the clinical data. The average confidence intervals are visualized in the graph in Figure 4A.
Table 3. P values for the Wilcoxon signed-rank tests on the 95% CIs for K trans between the different methods.
Patlak | Patlak+delay | Patlak fixed | Patlak fixed+delay | AATH | AATH+delay | NLR | NLR+delay | NLR+Ve | NLR+Ve+delay | Simpl. NLR | |
---|---|---|---|---|---|---|---|---|---|---|---|
Patlak+delay | 0.001 | ||||||||||
Patlak fixed | 0 | 0 | |||||||||
Patlak fixed+delay | 0 | 0 | 0 | ||||||||
AATH | 0.056 | 0.035 | 0.015 | 0.052 | |||||||
AATH+delay | 0.126 | 0.073 | 0.012 | 0.030 | 0.018 | ||||||
NLR | 0 | 0 | 0 | 0 | 0 | ||||||
NLR+delay | 0 | 0 | 0 | 0 | 0 | 0 | 0.823 | ||||
NLR+Ve | 0.232 | 0.145 | 0.009 | 0.017 | 0.005 | 0.153 | 0 | 0 | |||
NLR+Ve+delay | 0.048 | 0.030 | 0.017 | 0.062 | 0.737 | 0.014 | 0 | 0 | 0.002 | ||
Simpl. NLR | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.002 | 0 | 0 | |
Simpl. NLR+delay | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.695 |
Abbreviations: AATH, adiabatic approximation to the tissue homogeneity; CI, confidence interval; NLR, nonlinear regression; Ve, extravascular distribution volume.
Probabilities smaller than 0.001 are considered as significant and written as 0.
Because the steady-state time for Patlak analysis was defined as the TTP plus 3.5 × the standard deviation of the first-pass bolus, on average 9 time frames were included for Patlak analysis.
Figure 4A, and Table 2 together with Table 3 show that the Ktrans values that are estimated using the NLR methods with irreversible leakage (Ve=∞) were significantly more reliable than the Patlak methods. The introduction of reversible leakage, as in the AATH method and NLR+Ve, more than doubled the width of the CI of the estimation. The difference in reliability between the full and simplified NLR methods was found to be very small.
Figure 4A also shows that fixating the CBV significantly improved the reliability of the Patlak estimates.
The delay correction had a minor effect on the CIs. With P values higher than 0.001, the CIs of the standard Patlak, AATH, NLR, NLR+Ve, and simplified NLR methods were not significantly different from the delay corrected versions. The delay corrected CBV-fixed Patlak method performed slightly but significantly worse than its delay-sensitive version (P<0.001).
Also, the MTT distribution parameter a had a minor effect. The CI of the NLR+Ve method (a=0.632) was not significantly different from the interval of the AATH method (a=1). The CIs of the simplified NLR and simplified NLR+delay methods (a=1) were slightly but significantly smaller than respectively the NLR and NLR+delay methods (a=0.632).
Figure 4B gives an overview of the average computation time for each method. It is not surprising that the simplest method, standard Patlak, was the fastest with 0.3 second per slice (512 × 512 pixels and 31 time frames). The other Patlak methods require additional input provided by a gamma variate fit, extending the computation time to 5.9 seconds per slice. The simplified NLR methods had computation times of respectively 5 and 9 seconds per slice, where the other NLR methods required between 19 and 45 seconds.
Discussion
This study uses CIs to compare the reliability between different methods for estimating Ktrans values. The ‘reliability' can be thought of as a quantity that is inversely proportional to the width of these CIs. The experiments showed that the simplified NLR method has a CI that is a bit smaller than the full NLR methods, and significantly smaller than the Patlak methods in both the simulations and clinical measurements.
‘Reliability' is a nonscientific term that should be used with care. Some ‘reliability metrics', like the Akaike information criterion,34 quantify the goodness of fit of a model. For two reasons, however, this type of metric is not applicable to this study. First, the Patlak fits are applied to different (linearized) data than the nonlinear fits; and therefore, the goodness of fit between these methods may not be compared. Second, the reliability of a single parameter, Ktrans, is of importance, rather than the goodness of fit of the complete model. Not all time frames have an equal contribution to the estimated Ktrans, and therefore the CI, which is specific to this parameter, is more appropriate.
A wider CI means a larger standard deviation in repeated measurements. For Ktrans values close to zero, the probability distribution is skewed because the estimates are constrained to positive values, and therefore the mean will have a positive bias. This phenomenon is visible in Figures 2B and 2D. The estimated CI, however, appears to be independent of the value for Ktrans, which makes it a valid measure for evaluating the reliability of the methods, even if the true Ktrans is close to zero. It has been shown that the estimates from the clinical data are in line with the simulations, for which reason it can be concluded that the variation in average Ktrans between the methods has to be addressed to a variation in the CIs rather than a bias in estimates.
The standard Patlak method was found to be two to three times less reliable than the NLR and simplified NLR method in both the simulated and clinical cases. However, fixating the CBV to a value estimated with a more sophisticated method, which is usually available anyway, roughly doubles its reliability. This means that fixating the CBV in the Patlak plot is a simple but very effective way to enhance the reliability of the permeability estimates in general.
The standard Patlak method showed a decrease in reliability for long transit times. The performance of this method could in those cases probably be increased by determining the steady state of the tissue attenuation curve instead of the AIF, as was performed in this study. A longer MTT means that it takes more time for the capillary concentration to reach a steady state and therefore fewer samples should be included in the Patlak plot.
The addition of a delay time tΔ as an extra parameter had a minor effect on the reliability of the Ktrans. It has although been proven that delay-insensitive methods, i.e., methods that incorporate tΔ, give better estimates for the CBV, CBF, and MTT.8 Therefore, and because the CIs for the NLR methods did not increase despite the introduction of an extra-free parameter, it can be concluded that tΔ is an appropriate additional parameter for the NLR methods.
The shape of the MTT distribution, controlled by the parameter a in Equation 5, is another feature that could improve the credibility of the IRF and therefore enhance the reliability of the Ktrans estimates. The methods that use a=0.632 instead of a=1 have IRFs that are thought to be more realistic,17 but none of those methods showed a significant narrower CI on the clinical data, nor did the simulations show significant differences between these methods. Although this parameter might increase the accuracy and reliability of other perfusion parameters, such as the CBF and MTT, it did not affect the estimation of Ktrans.
The simulations showed that the AATH and NLR+Ve methods, both assuming reversible leakage, overestimate Ktrans in case the leakage is virtually irreversible (Figure 2D). This is most likely caused by the error in the estimated extravascular distribution volume, Ve (Equations 2 and 5). In case Ve is underestimated, i.e., the model overestimated the washout from the extravascular space, then Ktrans needs to be larger to compensate for the measured concentration levels. In theory, a Ve of nearly zero allows high Ktrans values without noticeable leakage, because any leaked contrast is washed out instantly. The reliability of the AATH and NLR+Ve methods increases with larger Ktrans values, in the order of 2 to 10 mL/min per 100 g, which can be explained by the fact that a higher permeability results in better Ve estimates. Therefore, it cannot be concluded from our study that AATH and NLR+Ve perform worse than the other NLR methods in general. Models that account for reversible leakage are more applicable in pathologies with high vascular permeability, such as tumors, and in those particular cases they will likely give more reliable estimates.
On many points, the NLR method provides a more sound theoretical basis than Patlak analysis for permeability analysis, and gamma variate fits or deconvolution8, 35 for perfusion analysis. First, the NLR method does not make any assumptions of the shape of the attenuation curves themselves, but rather on the process that transforms the AIF into a tissue curve. The curves do not necessarily need to have a gamma variate-like profile, nor do they have to reach a steady state. A potential second pass bolus due to recirculation does not hamper the analysis. Second, at about tm seconds after the BAT, the permeability will start to affect the shape of the attenuation–time curve measured in the tissue, including part of the first-pass bolus. As opposed to the Patlak method, which uses only steady-state time frames, the NLR methods include all time frames. This means that no potentially useful information is wasted, and the results do not depend on the definition of the steady state. Third, because the NLR methods do not transform the attenuation curves, the (approximate) normal distribution of the measurement errors is preserved, which fulfills the requirements for proper least squares fitting. In linearized regression using a Patlak plot, this is no longer the case. Values are divided by Cc(t), which is a nonlinear operation that distorts the measurement errors. Fourth, all perfusion parameters, including permeability, are measured using a single method in which a change in one parameter affects all others. This reduces the bias in estimates that are influenced by other relevant factors that a method does not account for. For example, if the permeability is significant, then the intravascular blood volume can be biased if this is estimated by a method does not account for leakage into the extravascular volume.
A disadvantage of NLR is that it is an iterative method, and so a straightforward implementation is time consuming. This is most likely the reason why currently this technique is not much used in CTP analysis yet. The simplified NLR method, however, tackles two bottlenecks by omitting the need for convolutions and the calculation of exponentials, and is thereby at least four times faster than the full NLR methods. By further increasing the performance using, e.g., parallel computing or GPU acceleration the analysis of high-resolution volumes in a clinical setting might be feasible.
In conclusion, the CI, and thereby the reliability, of the simplified NLR method is similar to the full NLR methods, and better than the Patlak methods in both the simulations and clinical measurements. The simplified NLR analysis just takes 5 seconds per 512 × 512 slice, making it suitable for time-critical clinical use. The simplified NLR method therefore seems to be a superior alternative to Patlak analysis. Further research is required to evaluate the predictive value of the simplified NLR method for hemorrhagic transformation in acute ischemic stroke.
The techniques described in this study are potentially applicable to other purposes as well, like tumor assessment using dynamic contrast enhanced magnetic resonance imaging or positron emission tomography, even though the signal-to-noise ratio and kinetics might differ.
The authors declare no conflict of interest.
Footnotes
This work was supported by a research grant from the Dutch Technology Foundation STW ‘Perspectief' program ‘CARISMA', project ‘AIRSPACE' (11632).
References
- Lin K, Kazmi K, Law M, Babb J, Peccerelli N, Pramanik B. Measuring elevated microvascular permeability and predicting hemorrhagic transformation in acute ischemic stroke using first-pass dynamic perfusion CT imaging. Am J Neuroradiol. 2007;28:1292–1298. doi: 10.3174/ajnr.A0539. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bisdas S, Hartel M, Cheong L, Koh T, Vogl T. Prediction of subsequent hemorrhage in acute ischemic stroke using permeability CT imaging and a distributed parameter tracer kinetic model. J Neuroradiol. 2007;34:101–108. doi: 10.1016/j.neurad.2007.02.003. [DOI] [PubMed] [Google Scholar]
- Dankbaar JW, Hom J, Schneider T, Cheng SC, Lau BC, Van Der Schaaf I, et al. Dynamic perfusion CT assessment of the blood-brain barrier permeability: first pass versus delayed acquisition. Am J Neuroradiol. 2008;29:1671–1676. doi: 10.3174/ajnr.A1203. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Patlak CS, Blasberg RG, Fenstermacher JD. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab. 1983;3:1–7. doi: 10.1038/jcbfm.1983.1. [DOI] [PubMed] [Google Scholar]
- Patlak CS, Blasberg RG. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations. J Cereb Blood Flow Metab. 1985;54:584–590. doi: 10.1038/jcbfm.1985.87. [DOI] [PubMed] [Google Scholar]
- Larsson HBW, Courivaud F, Rostrup E, Hansen AE. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T1-weighted MRI at 3 tesla. Magn Reson Med. 2009;62:1270–1281. doi: 10.1002/mrm.22136. [DOI] [PubMed] [Google Scholar]
- Motulsky HJ, Ransnas LA. Fitting curves to data using nonlinear regression: a practical and nonmathematical review. FASEB J. 1987;1:365–374. [PubMed] [Google Scholar]
- Kudo K, Sasaki M, Yamada K, Momoshima S, Utsunomiya H, Shirato H, et al. Differences in CT perfusion maps generated by different commercial software: Quantitative analysis by using identical source data of acute stroke patients. Radiology. 2010;254:200–209. doi: 10.1148/radiol.254082000. [DOI] [PubMed] [Google Scholar]
- Roberts HC, Roberts TPL, Brasch RC, Dillon WP. Quantitative measurement of microvascular permeability in human brain tumors achieved using dynamic contrast-enhanced MR imaging: correlation with histologic grade. Am J Neuroradiol. 2000;21:891–899. [PMC free article] [PubMed] [Google Scholar]
- Konstas AA, Goldmakher GV, Lee TY, Lev MH. Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke, part 1: theoretic basis. Am J Neuroradiol. 2009;30:662–668. doi: 10.3174/ajnr.A1487. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lee TY, Purdie TG, Stewart E. CT imaging of angiogenesis. Q J Nucl Med. 2003;47:171–187. [PubMed] [Google Scholar]
- Sourbron SP, Buckley DL. Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability. Phys Med Biol. 2012;57:R1–R33. doi: 10.1088/0031-9155/57/2/R1. [DOI] [PubMed] [Google Scholar]
- Lawrence KSS, Lee TY. An adiabatic approximation to the tissue homogeneity model for water exchange in the brain: I. Theoretical derivation. J Cereb Blood Flow Metab. 1998;18:1365–1377. doi: 10.1097/00004647-199812000-00011. [DOI] [PubMed] [Google Scholar]
- Axel L. A method of calculating brain blood flow with a CT dynamic scanner. Adv Neurol. 1981;30:67–71. [PubMed] [Google Scholar]
- Mlynash M, Eyngorn I, Bammer R, Moseley M, Tong DC. Automated method for generating the arterial input function on perfusion-weighted MR imaging: validation in patients with stroke. Am J Neuroradiol. 2005;26:1479–1486. [PMC free article] [PubMed] [Google Scholar]
- Fischer MA, Donati OF, Reiner CS, Hunziker R, Nanz D, Boss A. Feasibility of semiquantitative liver perfusion assessment by ferucarbotran bolus injection in double-contrast hepatic MRI. J Magn Reson Imaging. 2012;36:168–176. doi: 10.1002/jmri.23611. [DOI] [PubMed] [Google Scholar]
- Bredno J, Hom J, Schneider T, Wintermark M.Simulation-based validation and arrival-time correction for Patlak analyses of perfusion-CT scans Proceedings of SPIE vol. 72622009. p72620G [Google Scholar]
- Schneider T, Hom J, Bredno J, Dankbaar J, Cheng SC, Wintermark M. Delay correction for the assessment of blood-brain barrier permeability using first-pass dynamic perfusion CT. Am J Neuroradiol. 2011;32:E134–E138. doi: 10.3174/ajnr.A2152. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sawada Y, Patlak CS, Blasberg RG. Kinetic analysis of cerebrovascular transport based on indicator diffusion technique. Am J Physiol. 1989;256:H794–H812. doi: 10.1152/ajpheart.1989.256.3.H794. [DOI] [PubMed] [Google Scholar]
- Johnson JA, Wilson TA. A model for capillary exchange. Am J Physiol Legacy Content. 1966;210:1299–1303. doi: 10.1152/ajplegacy.1966.210.6.1299. [DOI] [PubMed] [Google Scholar]
- Tofts PS, Brix G, Buckley DL, Evelhoch JL, Henderson E, Knopp MV, et al. Estimating kinetic parameters from dynamic contrast-enhanced T1-weighted MRI of a diffusable tracer: standardized quantities and symbols. J Magn Reson Imaging. 1999;10:223–232. doi: 10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s. [DOI] [PubMed] [Google Scholar]
- Bredno J, Olszewski ME, Wintermark M. Simulation model for contrast agent dynamics in brain perfusion scans. Magn Reson Med. 2010;64:280–290. doi: 10.1002/mrm.22431. [DOI] [PubMed] [Google Scholar]
- Kudo K, Sasaki M, Ogasawara K, Terae S, Ehara S, Shirato H. Difference in tracer delay-induced effect among deconvolution algorithms in CT perfusion analysis: quantitative evaluation with digital phantoms. Radiology. 2009;251:241–249. doi: 10.1148/radiol.2511080983. [DOI] [PubMed] [Google Scholar]
- Konstas AA, Lev MHCT. Perfusion imaging of acute stroke: the need for arrival time, delay insensitive, and standardized postprocessing algorithms. Radiology. 2010;254:22–25. doi: 10.1148/radiol.09091610. [DOI] [PubMed] [Google Scholar]
- Larson KB, Markham J, Raichle ME. Tracer-kinetic models for measuring cerebral blood flow using externally detected radiotracers. J Cereb Blood Flow Metab. 1987;7:443–463. doi: 10.1038/jcbfm.1987.88. [DOI] [PubMed] [Google Scholar]
- Nelder JA, Mead R. A simplex method for function minimization. Comput J. 1965;74:308–313. [Google Scholar]
- Press WH, Teukolsky SA, Vetterling WT, Flannery BP.Numerical recipes The Art of Scientific Computing3rd edn.Cambridge University Press: New York, NY; 2007 [Google Scholar]
- Wiesmann MCT. Perfusion of the brain. Visions J (Online) 2006;9:6–9. [Google Scholar]
- Klein S, Staring M, Murphy K, Viergever MA, Pluim J. Elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging. 2010;29:196–205. doi: 10.1109/TMI.2009.2035616. [DOI] [PubMed] [Google Scholar]
- Mendrik AM, Vonken E, van Ginneken B, de Jong HW, Riordan A, van Seeters T, et al. TIPS bilateral noise reduction in 4D CT perfusion scans produces high-quality cerebral blood flow maps. Phys Med Biol. 2011;56:3857–3872. doi: 10.1088/0031-9155/56/13/008. [DOI] [PubMed] [Google Scholar]
- Van der Schaaf I, Vonken EJ, Waaijer A, Velthuis B, Quist M, van Osch T. Influence of partial volume on venous output and arterial input function. Am J Neuroradiol. 2006;27:46–50. [PMC free article] [PubMed] [Google Scholar]
- Wintermark M, Flanders AE, Velthuis B, Meuli R, Van Leeuwen M, Goldsher D, et al. Perfusion-CT assessment of infarct core and penumbra receiver operating characteristic curve analysis in 130 patients suspected of acute hemispheric stroke. Stroke. 2006;37:979–985. doi: 10.1161/01.STR.0000209238.61459.39. [DOI] [PubMed] [Google Scholar]
- Rempp KA, Brix G, Wenz F, Becker CR, Gückel F, Lorenz WJ. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology. 1994;193:637–641. doi: 10.1148/radiology.193.3.7972800. [DOI] [PubMed] [Google Scholar]
- Akaike H. A new look at the statistical model identification. IEEE Trans Autom Control. 1974;196:716–723. [Google Scholar]
- Wu O, Østergaard L, Weisskoff RM, Benner T, Rosen BR, Sorensen AG. Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix. Magn Reson Med. 2003;501:164–174. doi: 10.1002/mrm.10522. [DOI] [PubMed] [Google Scholar]