Abstract
Despite major advances in neuroimaging, no lesion is visualized on MRI in up to a quarter of patients with drug-resistant focal epilepsy presenting for presurgical evaluation. These patients demonstrate poorer surgical outcomes than those with lesion seen on MRI. Accurate localization of the seizure onset zone (SOZ) is more difficult in MRI-negative patients and often requires invasive EEG recordings. Positron emission tomography (PET) and magnetoencephalography (MEG) have been proposed as clinically relevant tools to localize the SOZ prior to intracranial EEG recordings. However, there is no consensus regarding the optimal gold standard that should be used for assessing the performance of these presurgical investigations. Here, we review the current knowledge concerning the usefulness of PET and MEG for presurgical assessment of MRI-negative epilepsy. Beyond the individual diagnostic performance of MEG and of different PET tracers, including [18F]-fluorodeoxyglucose, [11C]flumazenil, and markers of 5-HT1A receptors, recent data suggest that the combination of PET and MEG might provide greater sensitivity and specificity than that of each of the two individual tests in patients with normal MRI.
Keywords: PET, magnetoencephalography, partial epilepsy, epilepsy surgery
Introduction
Patients’ selection for epilepsy surgery is a two-step procedure that first aims to identify potential candidates for presurgical evaluation, and then to determine in each assessed individual whether benefit:risk ratio for surgery is acceptable (1). This process primarily requires localizing the seizure onset zone (SOZ), i.e., the minimum amount of brain tissue that should be resected to render the patient seizure-free. The identification of the SOZ results from the integration of a set of arguments, particularly electro-clinical data obtained during long-term video-EEG monitoring and results of optimal high-resolution brain MRI (1). Identification of a structural abnormality on brain MRI is of paramount importance, since such abnormality usually represents the core of the presurgical and surgical strategy. Post-operative seizure outcome positively correlates with the presence of an epileptogenic brain lesion on MRI (2). Despite major advances in neuroimaging, MRI remains negative in up to a quarter of patients presenting for presurgical evaluation (3). Poorer surgical outcome in patients with MRI-negative partial epilepsy partly reflects the difficulties for determining the exact localization and extension of the SOZ. In these patients, intracranial EEG recording is usually mandatory to ensure the delineation of the SOZ. Whatever the invasive recording technique used, subdural electrodes or stereoelectroencephalography (SEEG), brain sampling remains limited by safety issues. The placement of subdural or depth electrodes should therefore be individualized according to the most possibly precise and reliable hypothesis regarding the localization of the SOZ. Overall, the outcome of invasive EEG monitoring primarily depends on the quality and interpretation of the non-invasive data used to decide of the brain regions to be targeted.
Positron emission tomography (PET) and magnetic source imaging (MSI) have been proposed as valuable tools to help localizing the SOZ prior to intracranial EEG recordings. However, the comparative performance of these presurgical investigations remains controversial, especially in patients with MRI-negative epilepsy. On the other hand, recent data suggest that PET and magnetoencephalography (MEG) might be complementary, with their combination yielding increased sensitivity and specificity as compared to each test used in isolation. Here, we review the current knowledge concerning the usefulness of PET and MEG for presurgical assessment of MRI-negative epilepsy and discuss the impact of combining their results on SOZ localization.
PET Studies in MRI-Negative Focal Epilepsy
Several PET tracers have been evaluated as potential markers of the SOZ in patients with epilepsy. [18F]-fluorodeoxyglucose ([18F]-FDG), which brain accumulation reflects the local cerebral metabolic rate of glucose, is the most widely used tracer in patients with epilepsy (4). However, multiples other tracers that target neurotransmitter systems have also been studied in epilepsy, primarily those labeling GABAA and 5-HT1A receptors (1).
Before discussing the individual diagnostic performance of these tracers, some general methodological points should be underscored: (i) whatever the radiotracer used, PET data are usually obtained during the interictal period. Although programing ictal PET is feasible (5), its constraints, related to radioligands kinetics and images acquisition, usually overcome its potential benefit in daily practice. Possibility of seizure occurrence during “interictal” PET acquisition should however be taken into account since this might result in false lateralization of PET abnormality; (ii) PET findings should be assessed with reference to structural imaging, especially in patients with normal MRI. Indeed, PET/MRI coregistration allows to more easily distinguish true hypometabolism from the sole impact of focal atrophy or wide sulcus, and to detect subtle MRI abnormalities which would not have been recognized otherwise. It has been shown that [18F]-FDG-PET/MRI coregistration in patients with focal cortical dysplasia (FCD) improved detection of focal metabolic abnormalities by 35–40%, both in patients with abnormal and normal MRI (6). A study in children with MRI-negative epilepsy also reported that coregistered [18F]-FDG-PET/MRI data resulted in the detection of subtle MRI abnormalities not previously recognized in 9 out 31 patients (7); (iii) interpretation of PET images primarily relies on standard visual analysis, but statistical analysis, with the widely used Statistical Parametric Mapping (SPM) software, might improve the diagnostic yield of PET. Over the past years, some authors have thus reported that the use of SPM can result in greater sensitivity and specificity of PET imaging in patients with MRI-negative epilepsy (8, 9). However, other studies did not confirm this finding (10). In addition, various methodological pitfalls of SPM analyses should be kept in mind, including artifacts of various origins, presence of abnormalities in some control subjects (11), and age difference between patients and controls (12). In our clinical experience of more than 300 FDG-PET where both visual and SPM analyses were performed, the latter proved useful in two situations: (i) detecting subtle hypometabolism over the mesial frontal or parietal regions, where spill-over and partial volume effects often result in bilateral and symmetrical abnormalities difficult to capture with visual analysis and (ii) demonstrating the area of maximum hypometabolism in patients with multiple or extensive visually detected abnormalities. Improvement in the performance of SPM findings can be obtained by running such voxel-based analysis on maps of asymmetry index between the two hemispheres, rather than on the raw data (13).
[18F]-FDG-PET
Hypometabolism on interictal [18F]-FDG-PET is a hallmark of the SOZ as well as surrounding areas (4). Several studies have evaluated the sensitivity and specificity of [18F]-FDG-PET in patients with MRI-negative focal epilepsy (see Table 1).
Table 1.
Study | Epilepsy | Age group | Number of patients | Abnormal PET findings (%) | Specificity of PET abnormalities |
Remarks | |
---|---|---|---|---|---|---|---|
Concordant lateralization with the SOZ (%) | Focal hypometabolism concordant with the localization of SOZ (%) | ||||||
Juhasz et al. (14) | T, ET | Children and adults | 9 | 100 | 100 | 11 | – |
O’Brien et al. (15) | T, ET | Adults | 36 | – | – | 69.4 | – |
Hong et al. (16) | T, ET | Children and adults | 28 | 57.1 | 57.1 | 42.9 | – |
Carne et al. (17) | T | Adults | 30 | – | 86.7 | 33.3 | – |
Chapman et al. (18) | T, ET | Children and adults | 24 | – | 66.7 | 66.7 | – |
Lee et al. (19) | ET | Children and adults | 79 | – | 44.3 | – | – |
Bien et al. (20) | T, ET | Adults | 17 | 58.8 | – | 29.4 | – |
Jayakar et al. (21) | T, ET | Children | 10 | 100 | – | 60 | – |
Knowlton et al. (22, 23) | T, ET | Children and adults | 64 | 85.2 | – | 29 | – |
Brodbeck et al. (24) | T, ET | Children and adults | 9 | 77.8 | 77.8 | 55.5 | – |
Immonen et al. (25) | T | Adults | 17 | – | 58.8 | – | – |
Rubi et al. (7) | ET | Children | 31 | 67.7 | 58.1 | 32.2 | – |
Seo et al. (26) | ET | Children | 14 | 100 | 71.4 | 21.4 | – |
Chassoux et al. (10) | T, ET | Children and adults | 23 | 95.6 | 95.6 | 59.1 | Taylor-type FCD |
LoPinto-Khoury et al. (27) | T | Adults | 46 | 100 | 100 | – | All included patients had PET+/MRI− |
Gok et al. (28) | T | Adults | 38 | – | 84.1 | 6.7 | – |
T, temporal lobe epilepsy; ET, extra-temporal epilepsy; SOZ, seizure onset zone.
[18F]-FDG-PET abnormalities were observed in a majority of patients, both in adults and children. In the largest cohorts, abnormal PET was reported in 53–100% of patients (7, 12, 17, 20, 22, 27). However, the congruence between PET findings and the SOZ localization was generally low. Although abnormalities usually showed concordant lateralization with the SOZ, non-localizing multilobar abnormalities, or falsely localizing abnormalities were reported in up to 50% of patients (7, 16, 19, 20, 22, 29). Furthermore, in patients with focal abnormality, the hypometabolic area was frequently more widespread than the SOZ (7, 14, 16, 17, 26), although remote abnormalities appeared to be related to the location of the primary seizure focus (14, 17). In a cohort of 61 patients with temporal or extra-temporal MRI-negative epilepsy, where intracranial EEG was used as a gold standard to localize the SOZ, [18F]-FDG-PET sensitivity, and specificity were 39.5% (95% CI: 31.4–47.4) and 53.3% (95% CI: 30.0–76.0), respectively (22). When the resected area of the 51 patients with Engel class I surgical outcome served as a reference for defining the SOZ, [18F]-FDG-PET sensitivity, and specificity increased to 59% (95% CI: 47.4–67.4) and 79% (95% CI: 58.7–92.5), respectively (23). The concordance between [18F]-FDG-PET data and the SOZ was particularly low in patients with extra-temporal SOZ. Accordingly, sensitivity of [18F]-FDG-PET to detect focal hypometabolism concordant with the SOZ and to predict seizure outcome was <40% in the majority of studies which evaluated patients with extra-temporal epilepsy (7, 8, 16, 22, 26). However, two situations, in which the diagnostic accuracy of [18F]-FDG-PET in patients with MRI-negative epilepsy might be higher, should be individualized: (i) patients with mesial temporal lobe epilepsy without evidence of hippocampal sclerosis on MRI; and (ii) patients with MRI-negative Taylor-type focal cortical dysplasia.
In a series of 30 patients with MRI-negative temporal lobe epilepsy, [18F]-FDG-PET showed abnormalities concordant with SOZ localization in 26 patients (87%) (17). Among the subgroup of 17 patients with focal hypometabolism on [18F]-FDG-PET who had undergone temporal lobe surgery, 15 (88%) were seizure-free after a mean post-operative follow-up of 38 months, a surgical outcome similar to that observed in a control group that included patients with hippocampal sclerosis on MRI (17). Interestingly, the authors individualized some clinical differences between the two patient’s groups. Those with MRI-negative PET-positive temporal lobe epilepsy demonstrated lower frequency of history of febrile convulsions and of hippocampal sclerosis at pathological examination, but more widespread hypometabolism than those with hippocampal sclerosis on MRI (17). In a larger series of 46 patients with MRI-negative TLE and unilateral temporal hypometabolism on PET, 5-years seizure-free rate was 75%, versus 78% in the 147 patients with MRI signs of mesial temporal sclerosis (27).
Among patients with extra-temporal MRI-negative epilepsy, those with MRI-occult FCD demonstrate better post-operative seizure outcome than those with normal pathological examination of the surgical specimen (2, 30). Whether or not detected on MRI, Taylor-type FCD are typically associated with clearcut focal hypometabolism on [18F]-FDG-PET at the site of the malformation (10, 31, 32). In a recent study of 23 patients with histologically proven Taylor-type FCD and negative MRI, [18F]-FDG-PET disclosed a focal or regional hypometabolism in 22 patients (96%), 20 of whom were seizure-free post-operatively (10). Correlation with SEEG data in 20 patients showed that hypometabolic zones restricted to a single gyrus usually matched with the underlying epileptogenic FCD, whereas larger hypometabolic areas included the epileptogenic FCD but also cortical regions not involved at seizure onset. However, the detection of small hypometabolic areas associated with MRI-occult FCD can be challenging in some of the typical locations of such FCD, such as the bottom of the F1–F2 sulcus, if not appropriately oriented by electro-clinical data.
Overall, MRI-negative patients can be separated into two groups: (1) those with TLE or MRI-occult Taylor-type FCD where [18F]-FDG-PET demonstrates high sensitivity and specificity associated with excellent surgical outcome and (2) those with other types of MRI-negative drug-resistant partial epilepsy where both [18F]-FDG-PET and surgery proved less effective. This raises the issue as to whether normal or not clearly localizing [18F]-FDG-PET (i.e., multifocal or multilobar hypometabolism with unclear borders) should be interpreted as a reliable indicator of a very poor surgical prognosis, rather than as a limitation of PET.
Radioligands of receptors
Imaging of GABAA receptors
11C-flumazenil ([11C]-FMZ) is a selective antagonist of GABAA – benzodiazepine (BZD) receptors (4). The BZD receptors labeled with [11C]-FMZ represent modulator sites of the GABAA receptors, which are primarily expressed post-synaptically on the apical dendrites of neurons. A reduced FMZ binding, as observed in patients with partial epilepsies, is thought to primarily reflect an underlying neuronal loss. However, it has been shown that [11C]-FMZ PET can demonstrated transient and falsely lateralizing asymmetries, possibly reflecting seizure-related short-term plasticity of BZD receptors (33). In a test-re-test [11C]-FMZ PET study, significant seizure-related variations were observed in 5 out of 10 patients, including all three with MRI-negative temporal lobe epilepsy (34).
Several studies have evaluated the clinical utility of [11C]-FMZ in patients with MRI-negative focal epilepsy. Most studies evaluated [11C]-FMZ PET as a marker of the SOZ and compared it with [18F]-FDG-PET. In 2004, a review of the literature identified 45 patients with TLE and a normal MRI who had undergone [11C]-FMZ PET (35). [11C]-FMZ PET was abnormal in 38 patients (84%), but these abnormalities were considered as surgically informative in only 21 of them (47%). Similar results were observed in patients with extra-temporal epilepsy where [11C]-FMZ PET detected abnormalities in 73 out of 102 retrieved cases, including 52 which were judged as clinically relevant (35). Some studies suggested that [11C]-FMZ PET sensitivity and specificity might be greater than that of [18F]-FDG-PET in patients with MRI-negative epilepsy of both temporal and extra-temporal origin (14, 36, 37). However, other studies did not confirm these findings (29, 38). [11C]-FMZ PET has also been proposed to detect subtle MRI-occult cortical microdysgenesis, specifically heterotopic neurons within the periventricular white matter (39–41). However, it should be noted that most [11C]-FMZ PET studies in patients with MRI-negative epilepsies were performed more than 10 years ago, using less optimal MRI investigations than those currently available, raising the possibility that subtle MRI abnormalities might have been overlooked. One exception is a recent study that has used [18F]-FMZ instead of [11C]-FMZ, and reported correct localization of [18F]-FMZ abnormalities in 42% of patients with normal MRI, in comparison with 58.8% with [18F]-FDG-PET (42).
Imaging of 5-HT1A receptors
Three different 5-HT1A receptors antagonist have been used in epilepsy: [11C]WAY 100635, [18F]FCWAY, and [18F]MPPF (11). PET studies with either of these ligands showed a high level of binding in limbic (hippocampus, amygdala, parahippocampal gyrus) and paralimbic (temporal pole, insula, anterior, and posterior cingulate gyri) regions as compared with other neocortical areas (43). In patients with mesial TLE, decreased binding of all three tested tracers was consistently observed within the epileptogenic mesial temporal structures (4), with correlation between the degree of binding reduction and epileptogenicity as evaluated by intracranial EEG recording (44).
A limited number of patients with MRI-negative temporal lobe epilepsy have been investigated with 5-HT1A receptors PET. The studies evaluating [18F]MPPF in patients with temporal lobe epilepsy included a total of 10 patients with normal MRI, including nine with mesial temporal SOZ and one with neocortical temporal seizure focus (45, 46). Among the nine patients with a mesial SOZ, seven showed decreased [18F]MPPF within the epileptogenic limbic structure, including one with normal [18F]-FDG-PET (45, 46). Voxel-based analysis of asymmetry index maps increased the specificity of [18F]MPPF abnormalities (13).
Similar data were reported with both [18F]FCWAY and [11C]WAY 100635. [18F]FCWAY has been evaluated in 12 patients with MRI-negative TLE, nine of whom showed congruent abnormalities (75%) with intracranial EEG data or surgical outcome, with a slightly better sensitivity than that of [18F]-FDG-PET (47). Another six patients with MRI-negative epilepsy were evaluated with [11C]WAY 100635. All showed decreased ipsilateral mesial temporal binding potential of [11C]WAY 100635 (48), including four with unremarkable [18F]-FDG-PET (48).
Overall, these studies suggest that PET study of 5-HT1A receptors might be of interest in identifying or confirming temporal lobe SOZ, particularly when other imaging modalities, including [18F]-FDG-PET, are non-conclusive. Whether or not 5-HT1A receptor PET might have an added value in patients with epilepsy of extra-temporal origin remains to be investigated.
Other tracers
Among the other PET tracers evaluated in epilepsy, [11C]alpha-methyl-tryptophan (AMT) has a specific relevance in tuberous sclerosis, by showing increased AMT uptake within the epileptogenic tuber, selectively (49). However, this pattern is only observed in about half of patients in the majority of series, and in an even lower proportion of patients in our personal experience (50). Some studies have also shown abnormal AMT asymmetry or increased AMT binding in the presumed SOZ in patients with MRI-negative epilepsy, including a few cases with non-localizing [18F]-FDG-PET (51– 53).
MSI Studies in MRI-Negative Focal Epilepsy
MSI basics
Source localization of epileptic brain signals (such as epileptic spikes, fast oscillatory signals, or focal background slowing) can be used in the interictal period or during seizures using MEG. Source modeling of those signals and subsequent coregistration on individual brain MRI is referred to as MSI.
During the last 40 years, MEG instruments have evolved from a single-channel portable system to the modern whole head systems with more than 300 channels that are housed in multilayered shielded rooms. Moreover, validated source modeling procedures are now available in several commercial softwares, so that routine clinical use of MSI is now feasible (54–56).
Magnetic source imaging of epileptic spikes require several sequential steps (55, 57, 58): (i) recording of pathological signals with MEG; (ii) preprocessing of MEG data (artifact detection and removal, filtering, visual, or automatic detection of epileptic spikes, averaging or not of epileptic spikes to increase signal-to-noise ratio); (iii) modeling the conduction volumes of the brain using brain MRI tissue segmentation (spherical head models or more realistic head models which take into account individual brain geometry and possible conduction anisotropies between different brain elements); (iv) resolving the so-called inverse problem (i.e., determining the exact location of the neural source(s) best accounting for the recorded MEG data); and (v) co-registrating anatomical MRI data and functional data (brain sources of epileptic spikes). The choice of the conduction and inverse models is important as both solutions have a potential impact on MSI results (59, 60).
Inverse models can be divided into three families. Most clinical studies have used only the first family: classical single or multiple dipole modeling in which a current dipole source model is fitted to the MEG data. Parameters that have to be estimated are the dipole position and strength. The second and third families have been used much less. In the second family [example of methods: MUSIC (61), beamforming (62)], a source is found by scanning all possible positions in the brain. These methods require assumptions about which part of the measured data is signal and which is background or noise. The third family [examples of methods: LORETA (63) or MEM (64)], consists of linear inverse methods in which the data are modeled with only the source strengths as parameters for a distributed set of dipoles at known locations. Assumptions about or constraints on source strength are required for these methods.
The theoretical background of each inverse model is well known but studies comparing the location accuracy of all methods in clinical setting are lacking. Recently, de Gooijer-van de Groep et al. (65) showed that three well known inverse methods (MUSIC, SAMg2, and LORETA) had approximately the same localization accuracy, but that their sensitivity depended on the anatomical location of spike sources. The authors advised to use a combination of those methods in clinical practice.
Magnetic fields recorded by MEG are almost uninfluenced by variation in tissue conductivities (55, 66). Thus, simple models of the volume conductor for MEG source analysis offer high spatial resolution with only minimal distortion (60). In contrast, EEG recordings are more sensitive to volume currents. This explains why more complex models, derived from individual anatomy, are needed for optimal EEG source analysis, and why the latter is more prone to localization errors due to inaccurate segmentation of the brain compartments associated with distinct conductivity. This is especially relevant for patients with large brain lesions or malformations, and those who have undergone prior brain surgery. MEG also suffers limitations, being insensitive to exclusively radially oriented sources, such as those found at the depth of sulci or top of gyri (55, 66). As a consequence, activity from radial sources may be overlooked, while those from oblique source will suffer reduction in amplitude.
Magnetoencephalography benefit from high temporal resolution of less than a millisecond and, under optimal circumstances, spatial resolution of several millimeters (66). However, precisely estimating the accuracy of MSI localization would require reference information as to the actual source location of epileptic paroxysmal transients, which is seldom the case. The degree of inaccuracy may be calculated directly by modeling simulated data from known sources, or alternatively by creating current dipoles between two adjacent intracerebral electrodes in vivo. A mean localization error of about 10 mm may be accepted, but this can vary from a few millimeters to as much as a few centimeters. Indeed it is generally well accepted that the localization error: (i) is larger when the source is deeply located; (ii) is smaller when realistic head models are used, compared with spherical models; (iii) is smaller when the spatial sampling of MEG captors is increased; and (iv) decreases when the signal–noise ratio increases (66).
The diagnostic yield of MSI in MRI-negative patients
Evaluating the diagnostic yield of MSI requires to evaluate the sensitivity of the method and its accuracy. During the last 15 years, numerous studies have been performed to evaluate the sensitivity of MEG for: (a) the detection of epileptic spikes and (b) the detection of localized and focal sources of spikes (see Table 1). The vast majority of those studies have been performed in selected groups of patients referred for MEG evaluation because scalp-EEG disclosed frequent interictal spikes. Therefore, the sensitivity of MSI in the general population is not known. Moreover, very few of these studies specifically investigated MSI in negative MRI patients.
Based on existing studies, the sensitivity of MSI for the detection of focal sources of spikes is estimated between 35 and 90% (67–69). The wide range of sensitivity estimates is partly due to the different methodological approaches used to determine the spatial extent of spike sources. Most studies used spatial clustering of spikes modeled with single dipole models as an estimate of the volumetric extent of spiking volumes (26, 68–70). However, the extent of spikes’ cluster remains difficult to interpret since it depends on multiple factors including: (1) the spatio-temporal heterogeneity of spike’s MEG signal; (2) their signal- to-noise ratio; and (3) the statistical stability of the solution (71). Other modeling approaches have been proposed to overcome this limitation. Our group assesses the volumetric sources of spikes based on a beamforming method, which has been validated using intracranial EEG as a gold standard (Volumetric Imaging of Epileptic Spikes, VIES) (71). Using that method, we found that 8 out of 21 patients had focal sources of spikes while nine others had either lateralized but non-focal or bilateral sources of spikes. In successfully operated patients (i.e., seizure-free post-operatively), the proportion of those with focal sources of spikes on preoperative MEG varies between 71 and 100% (26, 68–70). Chowdhury et al. proposed to use the MEM source localization framework with realistic models based on cortical parcels to localize spatially extended generators (64). That study showed that methods implemented within the MEM framework were sensitive to all spatial extents of the sources ranging from 3 to 30 cm2, whatever were the number and size of the parcels defining the model.
The localizing value of MSI to delineate the SOZ has been evaluated in several studies with various gold standards (see Table 2). Those using intracranial EEG have reported high spatial congruence between the center of spiking areas determined with MSI and the SOZ, varying from 81 to 100% (26, 70, 72). The level of spatial overlap between MSI volumes and SOZ is lower due to: (a) spiking volumes determined with MSI are only a statistical model of the true brain spiking volumes and (b) brain spiking areas are usually more widespread than the true SOZ. The accuracy of MSI is higher for focal spiking volumes than for more widespread epileptiform paroxysms, since conventional modeling approaches with current equivalent dipoles are not well adapted to model sources of widespread abnormalities (71). For the latter, alternative methods using distributed sources models or beamforming methods have been proposed, but large-scale clinical validation is still lacking (71). The accuracy of MSI is also higher for superficial cortical sources with tangential orientation (e.g., neocortical areas of the frontal or parietal lobes), than for deep sources with radial orientation.
Table 2.
Study | Lobe | Channels | Number of patients | Inverse model | Patients’ age | Sensitivity | Accuracy |
---|---|---|---|---|---|---|---|
Minassian et al. (73) | TL, ET | 74/148 | 11 | SDM | 8–16 | Focal MEG: 8/11 | Congruence MEG/iEEG: 8/8 |
Surgery: 5/5 | MEG good outcome prediction: 4/8 | ||||||
Congruence MEG/surgery: NA | |||||||
RamachandranNair et al. (67) | TL, ET | 151 | 22 | SDM | 4–18 | Focal MEG: 18/22 | Congruence MEG/iEEG: NA |
Surgery: 9/9 | MEG good outcome prediction: 8/18 | ||||||
Congruence MEG/surgery: 18/22 | |||||||
Funke et al. (74) | TL, ET | 306 | 17 | SDM | 3–54 | Focal MEG: 6/17 | Congruence MEG/iEEG: NA |
Surgery: NA | MEG good outcome prediction: NA | ||||||
Congruence MEG/surgery: NA | |||||||
Seo et al. (26) | TL, ET | 275 | 14 | Beamforming | 3–18 | Focal MEG: 11/14 | Congruence MEG/iEEG: 9/11 |
Surgery: 6/7 | MEG good outcome prediction: 6/9 | ||||||
Congruence MEG/surgery: 9/11 | |||||||
Heers et al. (75) | ET | 74 | 3 | SDM | 19–45 | Focal MEG: 3/3 | Congruence MEG/iEEG: 3/3 |
Surgery: 2/2 | MEG good outcome prediction: 2/3 | ||||||
Congruence MEG/surgery: 3/3 | |||||||
Jung et al. (70) | TL, ET | 275 | 21 | Beamforming | 4–55 | Focal MEG: 8/21 | Congruence MEG/iEEG: 8/8 |
Surgery: 6/6 | MEG good outcome prediction: 6/7 | ||||||
Congruence MEG/surgery: 7/7 | |||||||
Widjaja et al. (76) | TL, ET | 151 | 26 | SDM | 0.9–17.6 | Focal MEG: 19/22 | Congruence MEG/iEEG: NA |
Surgery: 14/16 | MEG good outcome prediction: 14/18 | ||||||
Congruence MEG/surgery: 18/22 | |||||||
Wilenius et al. (72) | TL, ET | 306 | 13 | SDM | 12–47 | Focal MEG: 8/13 | Congruence MEG/iEEG: 8/8 |
Surgery: 5/7 | MEG good outcome prediction: 5/8 | ||||||
Congruence MEG/surgery: 7/22 | |||||||
Wu et al. (69) | TL, ET | 74/248 | 18 | SDM | 23–60 | Focal MEG: 12/18 | Congruence MEG/iEEG: NA |
Surgery: 10/10 | MEG good outcome prediction: 10/12 | ||||||
Congruence MEG/surgery: NA |
Studies defining SOZ as the resected area in patients seizure-free post-operatively have also reported high accuracy of MSI, between 80 and 100% (26, 68, 70). However, the accuracy of MSI should not be overestimated since only a minority of the single source localizations corresponding to individual spikes are finally included in the surgical resection. For example, Fischer et al. proposed to generate statistical volumes from the sources of individual spikes (77). Using that method, they showed that an average of 20% of the MEG volumes were included in the resection volumes. Moreover, there was a correlation between a favorable outcome and a high coverage of the MEG volumes by the resection volume. For patients with several clusters of spikes, seizure freedom is not directly related to the proportion of clusters of spikes being resected. As a whole, this suggests that MSI is a good indicator of the site of surgical resection, although it is not yet possible to delineate perfectly the cortical regions to be resected based on MSI results only.
Several MEG studies have shown that the presence of a focal spiking source was predictive of surgical success. A recent study showed that the odds-ratio (adjusted for epilepsy and MRI classification) for MSI prediction of seizure-free outcome was 4.4 (23). Tightly clustered spike dipoles were also associated with favorable surgery outcome. Our group recently showed that the extent of the spiking volume determined with MSI is predictive of likelihood of successful localization of the SOZ using intracranial EEG (70). For patients with a focal spiking volume, the SOZ defined by SEEG was clearly localized in all cases and most patients (6/7, 86%) had a good surgical outcome. Conversely, SEEG failed to delineate a SOZ in 57% of patients with a lateralized spiking volume, and in two patients with bilateral spiking volume.
Combination of PET and MSI Data during Presurgical Evaluation
Comparative advantages and limitations of PET and MSI in patients with MRI-negative epilepsy
According to the data discussed above, the advantages and limitations of PET imaging and MSI in the assessment of the SOZ in patients with MRI-negative epilepsy appear comparable. Both approaches show variable sensitivity among series, which could be explained by differences in the population studied, selection bias (e.g., operated patients or patients with clearcut spikes on scalp-EEG selected for MEG), and various methods used for data analysis. The presence of a single focal abnormality, either on MEG or PET, is associated with a good surgical outcome. However, the spatial congruence between the volume of PET or MEG abnormalities, and that of the SOZ, is far from perfect in many patients. Overall, the diagnostic accuracy of these investigations often remains insufficient to guide surgical decision without prior intracranial EEG in patients with MRI-negative epilepsy. Conversely, both investigations appear useful to guide the placement of depth or subdural electrodes, and help promoting an optimal sampling of the SOZ by these electrodes. A few MEG studies specifically investigated this issue (22, 78, 79). Knowlton et al. showed that MSI indicated additional electrode coverage in 18 of their 77 patients (not initially planed when MSI results were blinded but added after MSI was unblinded). Thirty-nine percent of those patients had seizures involving the additional electrodes implanted on the basis of MSI findings (78). Similarly, several studies have suggested that PET results might be useful to guide electrode placement and to improve coverage of the SOZ (36, 80).
Potential diagnostic added value of the combination of PET and MSI data
Considering the diagnostic performance of MSI and PET imaging, an important issue is to evaluate whether multimodal imaging using a combination of the two techniques might improve the presumptive localization of the SOZ, as compared to each technique used in isolation. Only two studies investigated this issue (23, 76). Knowlton and colleagues studied the localizing value of association of MSI and [18F]-FDG-PET in 51 patients with MRI-negative epilepsy who had achieved seizure freedom after epilepsy surgery (23). The proportion of patients with localized abnormalities on both MSI and [18F]-FDG-PET was low, with a combined sensitivity of 25% (95% CI 15.2–28.0). However, this diagnostic criterion was highly specific: 95% specificity for MSI + PET in comparison with 79% (58.7–92.5) for MSI or PET alone (23). In addition, when associated with intracranial EEG data, the localizing accuracy of [18F]-FDG-PET-MSI combination reached 100% (23). The other study included 22 children with MRI-negative epilepsy and showed similar results (76). When both [18F]-FDG-PET and MSI demonstrated abnormalities concordant with the cortical resection, specificity for Engel I seizure outcome was 100% (95.7–100) whereas sensitivity of the combination was lower than that of individual tests (55.0%) (76).
Further research issues
Despite these encouraging results, several issues remain to be addressed. The exact impact of combining MSI and PET on the placement of intracranial electrode, the final surgical decision, and the post-operative outcome has not been specifically investigated. According to the above studies, a positive impact is expected but still needs to be demonstrated and quantified in various populations (e.g., TLE and extra-temporal epilepsy). For instance, the sensitivity and the specificity of [18F]-FDG-PET in MRI-negative patients appears higher in TLE than in extra-temporal epilepsy, while the intrinsic characteristics of MSI result in higher accuracy in neocortical epilepsy than in deeply located epileptic foci, such as those responsible for mTLE. Combination of both tests might improve SOZ localization in both situations, but also requires careful interpretation of potential discordances between PET and MSI. In neocortical epilepsy, where [18F]-FDG-PET abnormalities are frequently more widespread than the SOZ, the detection of a MEG focus might help to refine the interpretation of PET images by highlighting spatially concordant abnormalities that may be the core of the epileptogenic network. In mesial temporal lobe epilepsy where a MEG focus is not detected or falsely localized outside the mesial temporal structure, second interpretation of MSI results in light of PET data might be useful. Both PET and MEG were found to help detecting subtle MRI abnormalities, and in particular small FCD, in patients previously considered MRI-negative (7, 10, 72, 74, 75). Whether the combination of [18F]-FDG-PET and MSI remains useful when one of the two investigations has allowed to identified a MRI-occult FCD also needs to be addressed. The combination of PET-MSI has been studied using [18F]-FDG-PET only. As detailed previously, other PET tracers might have greater sensitivity and specificity than [18F]-FDG-PET in specific situations (i.e., 5-HT1A receptors PET in TLE). It might thus be worth investigating the combination of MSI with these other tracers.
Conclusion
Positron emission tomography and MSI have been proposed as valuable tools to help localizing the SOZ prior to intracranial EEG recordings. However, each of these techniques suffers from limitations which might hamper a precise delineation of the SOZ in patients with MRI-negative focal epilepsy. Combination of PET and MEG might increase the sensitivity and specificity relatively to individual diagnostic tests in these patients, an issue which still needs to be formally demonstrated.
Conflict of Interest Statement
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References
- 1.Ryvlin P, Rheims S. Epilepsy surgery: eligibility criteria and presurgical evaluation. Dialogues Clin Neurosci (2008) 10:91–103 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Tellez-Zenteno JF, Hernandez Ronquillo L, Moien-Afshari F, Wiebe S. Surgical outcomes in lesional and non-lesional epilepsy: a systematic review and meta-analysis. Epilepsy Res (2010) 89:310–8 10.1016/j.eplepsyres.2010.02.007 [DOI] [PubMed] [Google Scholar]
- 3.Berg AT, Vickrey BG, Langfitt JT, Sperling MR, Walczak TS, Shinnar S, et al. The multicenter study of epilepsy surgery: recruitment and selection for surgery. Epilepsia (2003) 44:1425–33 10.1046/j.1528-1157.2003.24203.x [DOI] [PubMed] [Google Scholar]
- 4.Mauguiere F, Ryvlin P. The role of PET in presurgical assessment of partial epilepsies. Epileptic Disord (2004) 6:193–215 [PubMed] [Google Scholar]
- 5.Meltzer CC, Adelson PD, Brenner RP, Crumrine PK, Van Cott A, Schiff DP, et al. Planned ictal FDG PET imaging for localization of extratemporal epileptic foci. Epilepsia (2000) 41:193–200 10.1111/j.1528-1157.2000.tb00139.x [DOI] [PubMed] [Google Scholar]
- 6.Barbaro NM, Quigg M, Broshek DK, Ward MM, Lamborn KR, Laxer KD, et al. A multicenter, prospective pilot study of gamma knife radiosurgery for mesial temporal lobe epilepsy: seizure response, adverse events, and verbal memory. Ann Neurol (2009) 65:167–75 10.1002/ana.21558 [DOI] [PubMed] [Google Scholar]
- 7.Rubi S, Setoain X, Donaire A, Bargallo N, Sanmarti F, Carreno M, et al. Validation of FDG-PET/MRI coregistration in nonlesional refractory childhood epilepsy. Epilepsia (2011) 52:2216–24 10.1111/j.1528-1167.2011.03295.x [DOI] [PubMed] [Google Scholar]
- 8.Kim YK, Lee DS, Lee SK, Chung CK, Chung JK, Lee MC. (18)F-FDG PET in localization of frontal lobe epilepsy: comparison of visual and SPM analysis. J Nucl Med (2002) 43:1167–74 [PubMed] [Google Scholar]
- 9.Kumar A, Juhasz C, Asano E, Sood S, Muzik O, Chugani HT. Objective detection of epileptic foci by 18F-FDG PET in children undergoing epilepsy surgery. J Nucl Med (2010) 51:1901–7 10.2967/jnumed.110.075390 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Chassoux F, Rodrigo S, Semah F, Beuvon F, Landre E, Devaux B, et al. FDG-PET improves surgical outcome in negative MRI Taylor-type focal cortical dysplasias. Neurology (2010) 75:2168–75 10.1212/WNL.0b013e31820203a9 [DOI] [PubMed] [Google Scholar]
- 11.Hammers A. Epilepsy. In: Gruender G, editor. Neuromethods: Molecular Imaging in the Clinical Neurosciences. Springer: Humana Press; (2012). p. 377–95 [Google Scholar]
- 12.Archambaud F, Bouilleret V, Hertz-Pannier L, Chaumet-Riffaud P, Rodrigo S, Dulac O, et al. Optimizing statistical parametric mapping analysis of 18F-FDG PET in children. EJNMMI Res (2013) 3:2. 10.1186/2191-219X-3-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Didelot A, Mauguiere F, Redoute J, Bouvard S, Lothe A, Reilhac A, et al. Voxel-based analysis of asymmetry index maps increases the specificity of 18F-MPPF PET abnormalities for localizing the epileptogenic zone in temporal lobe epilepsies. J Nucl Med (2010) 51:1732–9 10.2967/jnumed.109.070938 [DOI] [PubMed] [Google Scholar]
- 14.Juhasz C, Chugani DC, Muzik O, Shah A, Shah J, Watson C, et al. Relationship of flumazenil and glucose PET abnormalities to neocortical epilepsy surgery outcome. Neurology (2001) 56:1650–8 10.1212/WNL.56.12.1650 [DOI] [PubMed] [Google Scholar]
- 15.O’Brien TJ, Hicks RJ, Ware R, Binns DS, Murphy M, Cook MJ. The utility of a 3-dimensional, large-field-of-view, sodium iodide crystal – based PET scanner in the presurgical evaluation of partial epilepsy. J Nucl Med (2001) 42:1158–65 [PubMed] [Google Scholar]
- 16.Hong KS, Lee SK, Kim JY, Lee DS, Chung CK. Pre-surgical evaluation and surgical outcome of 41 patients with non-lesional neocortical epilepsy. Seizure (2002) 11:184–92 10.1053/seiz.2001.0616 [DOI] [PubMed] [Google Scholar]
- 17.Carne RP, O’Brien TJ, Kilpatrick CJ, MacGregor LR, Hicks RJ, Murphy MA, et al. MRI-negative PET-positive temporal lobe epilepsy: a distinct surgically remediable syndrome. Brain (2004) 127:2276–85 10.1093/brain/awh257 [DOI] [PubMed] [Google Scholar]
- 18.Chapman K, Wyllie E, Najm I, Ruggieri P, Bingaman W, Luders J, et al. Seizure outcome after epilepsy surgery in patients with normal preoperative MRI. J Neurol Neurosurg Psychiatry (2005) 76:710–3 10.1136/jnnp.2003.026757 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Lee SK, Lee SY, Kim KK, Hong KS, Lee DS, Chung CK. Surgical outcome and prognostic factors of cryptogenic neocortical epilepsy. Ann Neurol (2005) 58:525–32 10.1002/ana.20569 [DOI] [PubMed] [Google Scholar]
- 20.Bien CG, Szinay M, Wagner J, Clusmann H, Becker AJ, Urbach H. Characteristics and surgical outcomes of patients with refractory magnetic resonance imaging-negative epilepsies. Arch Neurol (2009) 66:1491–9 10.1001/archneurol.2009.283 [DOI] [PubMed] [Google Scholar]
- 21.Jayakar P, Dunoyer C, Dean P, Ragheb J, Resnick T, Morrison G, et al. Epilepsy surgery in patients with normal or nonfocal MRI scans: integrative strategies offer long-term seizure relief. Epilepsia (2008) 49:758–64 10.1111/j.1528-1167.2007.01428.x [DOI] [PubMed] [Google Scholar]
- 22.Knowlton RC, Elgavish RA, Limdi N, Bartolucci A, Ojha B, Blount J, et al. Functional imaging: I. Relative predictive value of intracranial electroencephalography. Ann Neurol (2008) 64:25–34 10.1002/ana.21389 [DOI] [PubMed] [Google Scholar]
- 23.Knowlton RC, Elgavish RA, Bartolucci A, Ojha B, Limdi N, Blount J, et al. Functional imaging: II. Prediction of epilepsy surgery outcome. Ann Neurol (2008) 64:35–41 10.1002/ana.21419 [DOI] [PubMed] [Google Scholar]
- 24.Brodbeck V, Spinelli L, Lascano AM, Pollo C, Schaller K, Vargas MI, et al. Electrical source imaging for presurgical focus localization in epilepsy patients with normal MRI. Epilepsia (2010) 51:583–91 10.1111/j.1528-1167.2010.02521.x [DOI] [PubMed] [Google Scholar]
- 25.Immonen A, Jutila L, Muraja-Murro A, Mervaala E, Aikia M, Lamusuo S, et al. Long-term epilepsy surgery outcomes in patients with MRI-negative temporal lobe epilepsy. Epilepsia (2010) 51:2260–9 10.1111/j.1528-1167.2010.02720.x [DOI] [PubMed] [Google Scholar]
- 26.Seo JH, Holland K, Rose D, Rozhkov L, Fujiwara H, Byars A, et al. Multimodality imaging in the surgical treatment of children with nonlesional epilepsy. Neurology (2011) 76:41–8 10.1212/WNL.0b013e318204a380 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.LoPinto-Khoury C, Sperling MR, Skidmore C, Nei M, Evans J, Sharan A, et al. Surgical outcome in PET-positive, MRI-negative patients with temporal lobe epilepsy. Epilepsia (2012) 53:342–8 10.1111/j.1528-1167.2011.03359.x [DOI] [PubMed] [Google Scholar]
- 28.Gok B, Jallo G, Hayeri R, Wahl R, Aygun N. The evaluation of FDG-PET imaging for epileptogenic focus localization in patients with MRI positive and MRI negative temporal lobe epilepsy. Neuroradiology (2013) 55:541–50 10.1007/s00234-012-1121-x [DOI] [PubMed] [Google Scholar]
- 29.Ryvlin P, Bouvard S, Le Bars D, De Lamerie G, Gregoire MC, Kahane P, et al. Clinical utility of flumazenil-PET versus [18F]fluorodeoxyglucose-PET and MRI in refractory partial epilepsy. A prospective study in 100 patients. Brain (1998) 121:2067–81 10.1093/brain/121.11.2067 [DOI] [PubMed] [Google Scholar]
- 30.McGonigal A, Bartolomei F, Regis J, Guye M, Gavaret M, Trebuchon-Da Fonseca A, et al. Stereoelectroencephalography in presurgical assessment of MRI-negative epilepsy. Brain (2007) 130:3169–83 10.1093/brain/awm218 [DOI] [PubMed] [Google Scholar]
- 31.Chugani HT, Shields WD, Shewmon DA, Olson DM, Phelps ME, Peacock WJ. Infantile spasms: I. PET identifies focal cortical dysgenesis in cryptogenic cases for surgical treatment. Ann Neurol (1990) 27:406–13 10.1002/ana.410270408 [DOI] [PubMed] [Google Scholar]
- 32.Cohen-Gadol AA, Ozduman K, Bronen RA, Kim JH, Spencer DD. Long-term outcome after epilepsy surgery for focal cortical dysplasia. J Neurosurg (2004) 101:55–65 10.3171/jns.2004.101.1.0055 [DOI] [PubMed] [Google Scholar]
- 33.Ryvlin P, Bouvard S, Le Bars D, Mauguiere F. Transient and falsely lateralizing flumazenil-PET asymmetries in temporal lobe epilepsy. Neurology (1999) 53:1882–5 10.1212/WNL.53.8.1882 [DOI] [PubMed] [Google Scholar]
- 34.Bouvard S, Costes N, Bonnefoi F, Lavenne F, Mauguiere F, Delforge J, et al. Seizure-related short-term plasticity of benzodiazepine receptors in partial epilepsy: a [11C]flumazenil-PET study. Brain (2005) 128:1330–43 10.1093/brain/awh470 [DOI] [PubMed] [Google Scholar]
- 35.Hammers A. Flumazenil positron emission tomography and other ligands for functional imaging. Neuroimaging Clin N Am (2004) 14:537–51 10.1016/j.nic.2004.04.012 [DOI] [PubMed] [Google Scholar]
- 36.Muzik O, da Silva EA, Juhasz C, Chugani DC, Shah J, Nagy F, et al. Intracranial EEG versus flumazenil and glucose PET in children with extratemporal lobe epilepsy. Neurology (2000) 54:171–9 10.1212/WNL.54.1.171 [DOI] [PubMed] [Google Scholar]
- 37.Savic I, Thorell JO, Roland P. [11C]flumazenil positron emission tomography visualizes frontal epileptogenic regions. Epilepsia (1995) 36:1225–32 10.1111/j.1528-1157.1995.tb01066.x [DOI] [PubMed] [Google Scholar]
- 38.Debets RM, Sadzot B, van Isselt JW, Brekelmans GJ, Meiners LC, van Huffelen AO, et al. Is 11C-flumazenil PET superior to 18FDG PET and 123I-iomazenil SPECT in presurgical evaluation of temporal lobe epilepsy? J Neurol Neurosurg Psychiatry (1997) 62:141–50 10.1136/jnnp.62.2.141 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Hammers A, Koepp MJ, Hurlemann R, Thom M, Richardson MP, Brooks DJ, et al. Abnormalities of grey and white matter [11C]flumazenil binding in temporal lobe epilepsy with normal MRI. Brain (2002) 125:2257–71 10.1093/brain/awf233 [DOI] [PubMed] [Google Scholar]
- 40.Hammers A, Koepp MJ, Richardson MP, Hurlemann R, Brooks DJ, Duncan JS. Grey and white matter flumazenil binding in neocortical epilepsy with normal MRI. A PET study of 44 patients. Brain (2003) 126:1300–18 10.1093/brain/awg138 [DOI] [PubMed] [Google Scholar]
- 41.Yankam Nijiwa J, Bouvard S, Catenoix H, Mauguiere F, Ryvlin P, Hammers A. Periventricular [11C]flumazenil binding for predicting postoperative outcome in individual patients with temporal lobe epilepsy and hippocampal sclerosis. Neurorimage Clin (2013) 3:242–8 10.1016/j.nicl.2013.07.008 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Vivash L, Gregoire MC, Lau EW, Ware RE, Binns D, Roselt P, et al. 18F-flumazenil: a gamma-aminobutyric acid A-specific PET radiotracer for the localization of drug-resistant temporal lobe epilepsy. J Nucl Med (2013) 54:1270–7 10.2967/jnumed.112.107359 [DOI] [PubMed] [Google Scholar]
- 43.Costes N, Merlet I, Ostrowsky K, Faillenot I, Lavenne F, Zimmer L, et al. A 18F-MPPF PET normative database of 5-HT1A receptor binding in men and women over aging. J Nucl Med (2005) 46:1980–9 [PubMed] [Google Scholar]
- 44.Merlet I, Ryvlin P, Costes N, Dufournel D, Isnard J, Faillenot I, et al. Statistical parametric mapping of 5-HT1A receptor binding in temporal lobe epilepsy with hippocampal ictal onset on intracranial EEG. Neuroimage (2004) 22:886–96 10.1016/j.neuroimage.2004.02.014 [DOI] [PubMed] [Google Scholar]
- 45.Didelot A, Ryvlin P, Lothe A, Merlet I, Hammers A, Mauguiere F. PET imaging of brain 5-HT1A receptors in the preoperative evaluation of temporal lobe epilepsy. Brain (2008) 131:2751–64 10.1093/brain/awn220 [DOI] [PubMed] [Google Scholar]
- 46.Merlet I, Ostrowsky K, Costes N, Ryvlin P, Isnard J, Faillenot I, et al. 5-HT1A receptor binding and intracerebral activity in temporal lobe epilepsy: an [18F]MPPF-PET study. Brain (2004) 127:900–13 10.1093/brain/awh109 [DOI] [PubMed] [Google Scholar]
- 47.Liew CJ, Lim YM, Bonwetsch R, Shamim S, Sato S, Reeves-Tyer P, et al. 18F-FCWAY and 18F-FDG PET in MRI-negative temporal lobe epilepsy. Epilepsia (2009) 50:234–9 10.1111/j.1528-1167.2008.01789.x [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Savic I, Lindstrom P, Gulyas B, Halldin C, Andree B, Farde L. Limbic reductions of 5-HT1A receptor binding in human temporal lobe epilepsy. Neurology (2004) 62:1343–51 10.1212/01.WNL.0000123696.98166.AF [DOI] [PubMed] [Google Scholar]
- 49.Chugani DC, Chugani HT, Muzik O, Shah JR, Shah AK, Canady A, et al. Imaging epileptogenic tubers in children with tuberous sclerosis complex using alpha-[11C]methyl-L-tryptophan positron emission tomography. Ann Neurol (1998) 44:858–66 10.1002/ana.410440603 [DOI] [PubMed] [Google Scholar]
- 50.Rubi S, Costes N, Heckemann RA, Bouvard S, Hammers A, Marti B, et al. Positron emission tomography with α-[11C]Methyl-L-Tryptophan in tuberous sclerosis complex related epilepsy. Epilepsia (2013). 10.1111/epi.12412 [DOI] [PubMed] [Google Scholar]
- 51.Fedi M, Reutens D, Okazawa H, Andermann F, Boling W, Dubeau F, et al. Localizing value of alpha-methyl-L-tryptophan PET in intractable epilepsy of neocortical origin. Neurology (2001) 57:1629–36 10.1212/WNL.57.9.1629 [DOI] [PubMed] [Google Scholar]
- 52.Juhasz C, Chugani DC, Muzik O, Shah A, Asano E, Mangner TJ, et al. Alpha-methyl-L-tryptophan PET detects epileptogenic cortex in children with intractable epilepsy. Neurology (2003) 60:960–8 10.1212/01.WNL.0000049468.05050.F2 [DOI] [PubMed] [Google Scholar]
- 53.Natsume J, Kumakura Y, Bernasconi N, Soucy JP, Nakai A, Rosa P, et al. Alpha-[11C] methyl-L-tryptophan and glucose metabolism in patients with temporal lobe epilepsy. Neurology (2003) 60:756–61 10.1212/01.WNL.0000052682.99812.F5 [DOI] [PubMed] [Google Scholar]
- 54.Knowlton RC. Magnetoencephalography: clinical application in epilepsy. Curr Neurol Neurosci Rep (2003) 3:341–8 10.1007/s11910-003-0012-2 [DOI] [PubMed] [Google Scholar]
- 55.Stefan H. Magnetic source imaging. Rev Neurol (Paris) (2009) 165:742–5 10.1016/j.neurol.2009.07.014 [DOI] [PubMed] [Google Scholar]
- 56.Stufflebeam SM, Tanaka N, Ahlfors SP. Clinical applications of magnetoencephalography. Hum Brain Mapp (2009) 30:1813–23 10.1002/hbm.20792 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.Kaiboriboon K, Luders HO, Hamaneh M, Turnbull J, Lhatoo SD. EEG source imaging in epilepsy – practicalities and pitfalls. Nat Rev Neurol (2012) 8:498–507 10.1038/nrneurol.2012.150 [DOI] [PubMed] [Google Scholar]
- 58.Salmelin R, Baillet S. Electromagnetic brain imaging. Hum Brain Mapp (2009) 30:1753–7 10.1002/hbm.20795 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59.Baillet S, Mosher JC, Leahy RM. Electromagnetic brain mapping. IEEE Signal Process Mag (2001) 18:14–30 10.1109/79.962275 [DOI] [Google Scholar]
- 60.Tarkiainen A, Liljestrom M, Seppa M, Salmelin R. The 3D topography of MEG source localization accuracy: effects of conductor model and noise. Clin Neurophysiol (2003) 114:1977–92 10.1016/S1388-2457(03)00195-0 [DOI] [PubMed] [Google Scholar]
- 61.Mosher JC, Lewis PS, Leahy RM. Multiple dipole modeling and localization from spatio-temporal MEG data. IEEE Trans Biomed Eng (1992) 39:541–57 10.1109/10.141192 [DOI] [PubMed] [Google Scholar]
- 62.Hillebrand A, Singh KD, Holliday IE, Furlong PL, Barnes GR. A new approach to neuroimaging with magnetoencephalography. Hum Brain Mapp (2005) 25:199–211 10.1002/hbm.20102 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63.Pascual-Marqui RD, Michel CM, Lehmann D. Low resolution electromagnetic tomography: a new method for localizing electrical activity in the brain. Int J Psychophysiol (1994) 18:49–65 10.1016/0167-8760(84)90014-X [DOI] [PubMed] [Google Scholar]
- 64.Chowdhury RA, Lina JM, Kobayashi E, Grova C. MEG source localization of spatially extended generators of epileptic activity: comparing entropic and hierarchical Bayesian approaches. PLoS One (2013) 8:e55969. 10.1371/journal.pone.0055969 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 65.de Gooijer-van de Groep KL, Leijten FS, Ferrier CH, Huiskamp GJ. Inverse modeling in magnetic source imaging: comparison of MUSIC, SAM(g2), and sLORETA to interictal intracranial EEG. Hum Brain Mapp (2013) 34:2032–44 10.1002/hbm.22049 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 66.Mauguiere F, Merlet I, Jung J. Experimental neurophysiological techniques. In: Shorvon S, Perucca E, Engel J, editors. The Treatment of Epilepsy. Oxford: Blackwell Publishing; (2009). p. 829–49 [Google Scholar]
- 67.RamachandranNair R, Otsubo H, Shroff MM, Ochi A, Weiss SK, Rutka JT, et al. MEG predicts outcome following surgery for intractable epilepsy in children with normal or nonfocal MRI findings. Epilepsia (2007) 48:149–57 10.1111/j.1528-1167.2006.00901.x [DOI] [PubMed] [Google Scholar]
- 68.Widjaja E, Li B, Medina LS. Diagnostic evaluation in patients with intractable epilepsy and normal findings on MRI: a decision analysis and cost-effectiveness study. AJNR Am J Neuroradiol (2013) 34(1004–9):S1–2 10.3174/ajnr.A3474 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 69.Wu XT, Rampp S, Buchfelder M, Kuwert T, Blumcke I, Dorfler A, et al. Interictal magnetoencephalography used in magnetic resonance imaging-negative patients with epilepsy. Acta Neurol Scand (2013) 127:274–80 10.1111/j.1600-0404.2012.01712.x [DOI] [PubMed] [Google Scholar]
- 70.Jung J, Bouet R, Delpuech C, Ryvlin P, Isnard J, Guenot M, et al. The value of MEG for seizure-onset zone localization in MRI-negative partial epilepsy. Brain (2013) 136:3176–86 10.1093/brain/awt213 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 71.Bouet R, Jung J, Delpuech C, Ryvlin P, Isnard J, Guenot M, et al. Towards source volume estimation of interictal spikes in focal epilepsy using magnetoencephalography. Neuroimage (2012) 59:3955–66 10.1016/j.neuroimage.2011.10.052 [DOI] [PubMed] [Google Scholar]
- 72.Wilenius J, Medvedovsky M, Gaily E, Metsahonkala L, Makela JP, Paetau A, et al. Interictal MEG reveals focal cortical dysplasias: special focus on patients with no visible MRI lesions. Epilepsy Res (2013) 105:337–48 10.1016/j.eplepsyres.2013.02.023 [DOI] [PubMed] [Google Scholar]
- 73.Minassian BA, Otsubo H, Weiss S, Elliott I, Rutka JT, Snead OC., III Magnetoencephalographic localization in pediatric epilepsy surgery: comparison with invasive intracranial electroencephalography. Ann Neurol (1999) 46:627–33 [DOI] [PubMed] [Google Scholar]
- 74.Funke ME, Moore K, Orrison WW, Jr, Lewine JD. The role of magnetoencephalography in “nonlesional” epilepsy. Epilepsia (2011) 52(Suppl 4):10–4 10.1111/j.1528-1167.2011.03144.x [DOI] [PubMed] [Google Scholar]
- 75.Heers M, Rampp S, Stefan H, Urbach H, Elger CE, von Lehe M, et al. MEG-based identification of the epileptogenic zone in occult peri-insular epilepsy. Seizure (2012) 21:128–33 10.1016/j.seizure.2011.10.005 [DOI] [PubMed] [Google Scholar]
- 76.Widjaja E, Shammas A, Vali R, Otsubo H, Ochi A, Snead OC, et al. FDG-PET and magnetoencephalography in presurgical workup of children with localization-related nonlesional epilepsy. Epilepsia (2013) 54:691–9 10.1111/epi.12114 [DOI] [PubMed] [Google Scholar]
- 77.Fischer MJ, Scheler G, Stefan H. Utilization of magnetoencephalography results to obtain favourable outcomes in epilepsy surgery. Brain (2005) 128:153–7 10.1093/brain/awh333 [DOI] [PubMed] [Google Scholar]
- 78.Knowlton RC, Razdan SN, Limdi N, Elgavish RA, Killen J, Blount J, et al. Effect of epilepsy magnetic source imaging on intracranial electrode placement. Ann Neurol (2009) 65:716–23 10.1002/ana.21660 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 79.Sutherling WW, Mamelak AN, Thyerlei D, Maleeva T, Minazad Y, Philpott L, et al. Influence of magnetic source imaging for planning intracranial EEG in epilepsy. Neurology (2008) 71:990–6 10.1212/01.wnl.0000326591.29858.1a [DOI] [PMC free article] [PubMed] [Google Scholar]
- 80.Uijl SG, Leijten FS, Arends JB, Parra J, van Huffelen AC, Moons KG. The added value of [18F]-fluoro-D-deoxyglucose positron emission tomography in screening for temporal lobe epilepsy surgery. Epilepsia (2007) 48:2121–9 10.1111/j.1528-1167.2007.01197.x [DOI] [PubMed] [Google Scholar]