Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study.

Ramandeep Dugal 1, Bhargavi Railkar 2, Smita Musani 3
PMCID: PMC3845290  PMID: 24324310

Abstract

Background: Dimensional accuracy when making impressions is crucial to the quality of fixed prosthodontic treatment, and the impression technique is a critical factor affecting this accuracy. The purpose of this in vitro study was to compare the dimensional accuracy of the casts obtained from one step double mix, two step double mix polyvinyl siloxane putty- wash impression techniques using three different spacer thicknesses (0.5mm, 1mm and 1.5mm), in order to determine the impression technique that displays the maximum linear dimensional accuracy.

Materials & Methods: A Mild steel model with 2 abutment preparations was fabricated, and impressions were made 15 times with each technique. All impressions were made with an addition-reaction silicone impression material (Express, 3M ESPE) and customarily made perforated metal trays. The 1-step putty/light-body impressions were made with simultaneous use of putty and light-body materials. The 2-step putty/light-body impressions were made with 0.5-mm, 1mm and 1.5mm-thick metal-prefabricated spacer caps. The accuracy of the 4 different impression techniques was assessed by measuring 7 dimensions (intra- and inter abutment) (20-μm accuracy) on stone casts poured from the impressions of the mild steel model. The data were analyzed by one sample‘t’ test.

Results: The stone dies obtained with all the techniques had significantly larger or smaller dimensions as compared to those of the mild steel model (P<0.05). The order for highest to lowest deviation from the mild steel model was: single step putty/light body, 2-step putty/light body with 0.5mm spacer thickness, 2-step putty/light body1.5mm spacer thickness, and 2-step putty/light body with 1mm spacer thickness. Significant differences among all of the groups for both absolute dimensions of the stone dies, and their standard deviations from the master model (P<0.05), were noted.

Conclusions: The 2-step putty/light-body impression technique with 1mm spacer thickness was most dimensionally accurate impression methods in terms of resultant casts.

How to cite this article: Dugal R, Railkar B, Musani S. Dimensional accuracy when making impressions is crucial to the quality of fixed prosthodontic treatment, and the impression technique is a critical factor affecting this accuracy. J Int Oral Health 2013;5(5):85-94.

Key Words:  : accuracy, impression, laboratory research, polyvinyl siloxane, spacer thickness


Introduction

Making impressions to replicate oral conditions and tooth morphology is an integral part of prosthetic dentistry.

Polyvinyl siloxane impression materials have the best fine detail reproduction and elastic recovery of all available materials. Because there is no by-product, they possess remarkable dimensional stability and are odorless, tasteless and pleasant for patients. They are provided in wide range of viscosities, rigidities, and working and setting times.

Impression techniques can be categorized as monophase or dualphase. Techniques that use dual-phase materials such as the putty and light-body may be accomplished in one or two step. The one-step

putty/light-body technique requires less chair-side time. In the two-step putty/ light-body technique, the details are recorded by the light-body material only.1 The problem of accuracy of impressions has reported that over 89% of the impressions investigated had one or more observable errors2,3 Several factors can influence the quality of impressions, including technique4-8 the material5,9 the bulk of material2,10-12 and others.5,13,14

Therefore the objective of this study was to evaluate the dimensional accuracy of casts obtained from single step and double step polyvinyl siloxane putty wash impression techniques and in the double step impression technique 0.5mm, 1mm and 1.5mm spacer thicknesses were used to evaluate that which one gives maximum linear accuracy.

Materials and Methods

A mild steel master model containing 2 complete-crown, tapered abutment preparations was made. This model had two dies which simulated a clinical crown preparation with 6 degrees total taper. The occluso-gingival length of the die was 8 mm. the width of the die is 6mm and the base of the each die was 2 mm in height. Cross grooves were provided on the occlusal surfaces 1mm in depth to serve as reference points for making measurements (Figure 1). The two dies were then welded onto a horizontal metal platform measuring 120mm×40mm. A distance of 28 mm was maintained between the dies at the occlusal level. Two metallic stumps were fixed on either side of the horizontal metal platform for proper orientation of the perforated metal tray. Grooves were made on the platform for the escaping of the light body. A mark was made near the base of one die to recognize the right and left die after pouring the cast.

Fig. 1: METAL MASTER MODEL.

Fig. 1: METAL MASTER MODEL

This was then used as the definitive standardized model for the comparison of the impression

techniques. All of the impressions were made in customarily made perforated metal trays (Figure 2). These were fabricated maintaining a space of 7 mm for the impression material between the abutment preparation and the inner tray surface. Holes of 2 mm diameter were provided for mechanical retention and a tray adhesive (3M, ESPE VPS) was used. Four holes

Fig. 2: IMPRESSION TRAY.

Fig. 2: IMPRESSION TRAY

were provided on the base for proper orientation of the tray during impression making. Metallic spacers were fabricated.0.5 mm, 1mm and 1.5mm spacer caps were milled in polymethyl methacrylate resin and then they were cast in Ni-Cr alloy (Figure 3). Three wax pattern were fabricated and then were cast in Ni-Cr alloy. All the metallic components were fabricated from mild steel and were chrome plated to avoid rusting. 15 Impressions of the stainless steel model were made for each of the 4 techniques.

Fig. 3: METAL SPACER CAPS.

Fig. 3: METAL SPACER CAPS

Impressions were made with addition-reaction silicone impression material (3M ESPE Seefeld; Germany )Putty (Express TM XT Putty soft) and Light body (Express TM XT Light body)

The putty material was mixed with fingertips until the color was uniform, and all of the other materials were dispensed with an automatic mixing syringe. Care was taken to maintain a working time of three minutes for putty and three and half minutes for light body impression material as recommended by the manufacturer.

All the impressions were allowed to set on the master model for twice the recommended setting time in the mouth. This was in order to compensate for the polymerization occurring at room temperature (25 oC ±

Graph 1: Comparison of Mesio-distal distances across all study groups.

Graph 1: Comparison of Mesio-distal distances across all study groups

2 oC) rather than mouth temperature (32 oC ± 2 oC) in accordance with ADA specification No 19. 15-17

Proper care was taken to check metal to metal contact of the tray and the base to confirm exact seating of the tray.

The impressions (figure 4) were poured after thirty minutes simulating clinical situations.

Fig. 4: IMPRESSION.

Fig. 4: IMPRESSION

Group I - single step putty light body impression: Equal quantities of the base and catalyst of putty impression material were mixed and loaded into the tray, while the light body material was injected over the abutment preparations on the master model with the help of mixing gun. Once the light body material was injected, the tray was seated over the master model. All the impressions were allowed to set on the master model for twice the recommended setting time in the mouth (six minutes for putty and light body). Metal to metal contact was established and held in place with gentle finger pressure. (Figure 4)

Group II - two step impression with 0.5 mm of spacer: 0.5mm Ni-Cr spacer caps and the in between spacer plates were placed over the abutments .Equal quantities of the base and catalysts of putty impression material were mixed and then it was loaded into the tray. This tray was then seated over the master model till the material set. The tray was then removed from the master model, spacer caps and spacer plates were removed from the model and then the light body material was injected over the abutment preparations

Graph 2: Comparison of Facio-lingual distances across all study groups.

Graph 2: Comparison of Facio-lingual distances across all study groups

on the master model. Once the light body material was injected, the tray with putty was again seated over the master model. All the impressions were allowed to set with gentle finger pressure.

Group III - Two Step Impression with 1mm of spacer thickness: 1mm Ni-Cr spacer caps and the spacer plate were placed over the abutments .Equal quantities of the base and catalysts of putty impression material were mixed and then it was loaded into the impression tray. This tray was then seated over the master model till the material set. The tray was then removed from the master model, spacer caps and spacer plates were removed from the model and then the light body

Graph 3: Comparison of Abutment heights across all study groups.

Graph 3: Comparison of Abutment heights across all study groups

material was injected over the abutment preparations on the master model with the help of mixing gun. Once the light body material was injected, the tray with putty was again seated over the master model. All the impressions were allowed to set with gentle finger pressure.

Group IV – Two Step Impression with 1.5 mm of spacer thickness: 1.5mm Ni-Cr spacer caps and the in between spacer plate were placed over the abutments. Equal quantities of the base and catalysts of putty impression material were mixed and then it was loaded into the impression tray. This tray was then seated over the master model till the material set. The

Graph 4: Comparison of Inter-abutment distances across all study groups.

Graph 4: Comparison of Inter-abutment distances across all study groups

tray was then removed from the master model, spacer caps and spacer plates were removed from the model and then the light body material was injected over the abutment preparations on the master model with the help of mixing gun. Once the light body material was injected, the tray with putty was again seated over the master model. All the impressions were allowed to set with gentle finger pressure.

All the impressions were poured in type IV dental stone. A ratio of 22 ml water: 100 gm die stone was used as recommended. Models were allowed to set for one hour before they were separated. The master models as well as the stone models were laser scanned using laser scanner ‘LaserDenta’ and the virtual image was obtained. This image was then opened with the computer software Rhino 3D and interabutment and intraabutment measurements were made and compared. The measurements of interabutment, abutment height, faciolingual and mesiodistal distances were made.

Mesiodistal Distances

  • AB (die 1)

  • CD (die 2)

Faciolingual Distances

  • EF (die 1)

  • GH (die 2)

Abutment heights

  • EI (die 1)

  • GJ (die 2)

Inter - abutment distances

  • KL (between die 1 and die 2)

All the distances were calculated using Rhino 3D computer software. Each distance was measured three times and the mean value was calculated.

Table 2: Distance measurements for group II stone models.

Distances mm
AB CD EF GH EI GJ KL
1 5.42432 5.65587 5.91012 5.88653 8.53345 7.84548 28.3080
2 6.20489 5.78957 6.18624 5.96333 8.12327 7.93417 28.0134
3 5.84973 5.46792 5.35663 5.44882 7.62722 7.78130 27.4531
4 5.91784 5.94419 5.91274 5.78489 8.02110 7.83670 27.9266
5 5.73962 5.69516 5.63321 5.90498 7.52361 7.62291 27.9579
6 5.98601 6.04859 5.88921 5.86881 7.88260 7.86280 27.7407
7 5.95678 6.03454 5.87964 5.78956 8.07362 7.84435 27.6009
8 5.93456 6.11345 5.72435 5.98734 7.68894 7.79098 27.8456
9 5.99973 5.98796 5.89735 5.78365 7.88374 7.98976 27.9564
10 6.03345 5.87623 5.88345 5.80038 7.90029 7.60098 28.0134
11 6.00435 5.89364 5.98375 5.72235 8.00294 7.97743 28.2234
12 5.90433 5.85739 5.77839 5.98547 8.17765 7.68976 28.3990
13 5.99032 5.78936 5.90362 5.89684 7.68795 7.89987 27.9665
14 5.83430 6.00983 6.09472 5.97633 8.18874 7.95564 27.8435
15 5.75390 6.02365 5.93649 6.07483 7.97464 8.02234 27.5948

Results

(Table 5) lists the mean of distance measurements across various groups and the distribution of various distance measurements across various groups in comparison with master model

Table 5: The distribution of various distance measurements across various groups in comparison with master model.

Distance (mm) Group I (n=15) Group II (n=15)
Mesiodistal distances Mean (SD) Model Reference P-value Mean (SD) Model Reference P-value
AB 5.89 (0.16) 6.0 0.018 5.90 (0.18) 6.0 0.049
CD 6.00 (0.17) 6.0 0.998 5.88 (0.17) 6.0 0.018
Faciolingual distances Mean (SD) Model Reference P-value Mean (SD) Model Reference P-value
EF 6.06 (0.12) 6.0 0.089 5.86 (0.19) 6.0 0.017
GH 5.97 (0.19) 6.0 0.522 5.86 (0.15) 6.0 0.003
Abutment heights Mean (SD) Model Reference P-value Mean (SD) Model Reference P-value
EI 8.14 (0.11) 8 0.001 7.96 (0.26) 8 0.490
GJ 7.95 (0.08) 8 0.050 7.84 (0.13) 8 0.001
Inter - abutment distances Mean (SD) Model Reference P-value Mean (SD) Model Reference P-value
KL 27.5 (0.58) 28 0.004 27.9 (0.26) 28 0.274

P-values were obtained by simple‘t’ test with reference values by master model.

  1. Mesiodistal distances (Graph 1):

  2. Faciolingual distances (Graph 2):

  3. Abutment heights (Graph 3):

  4. Inter - abutment distance (Graph 4):

  5. Overall Group III had relatively better accuracy compared all other study groups.

Discussion:

In the present study, the accuracy of 4 different impression techniques was investigated. Some authors found that there was no difference in accuracy between one step and two step techniques18 while others

criticized the one step technique.19,20 Disadvantages include lack of control of the bulk of wash material and the high risk of capturing portions of the prepared margin in putty material rather than lower viscosity material. Putty is inadequate for fine detail reproduction.20

This present study was designed to determine the impression technique that displays the maximum linear dimensional accuracy for polyvinyl siloxane putty wash impression technique by assessing the linear dimensional change occurring along the various axes of tooth preparation in a partial arch impression .Thus, the null hypothesis of no difference between the master model and stone models and the accuracy of the four impression techniques was tested at α=0.05.

For group I casts, uneven results were obtained. There was decrease in mesiodistal distance of die 1 (AB) by 0.11mm as compared to the master model. The faciolingual distances showed an increase in distance of die 1 (EF) by 0.06mm and decrease in dimension of die 2 (GH) by 0.03mm from the master model. The height of die 1(EI) was more by 0.14mm than the master model, whereas the height of die 2 (GJ) was smaller by 0.05mm. The inter-abutment distance KL between die 1 and die 2 was found to be less than the master model by 0.50mm which was statistically insignificant.

The putty / wash one step technique for addition silicones was criticized by Chee and Donovan9 Clinically, smaller die dimensions would result in castings that are too small or too tight. In this situation, laboratory procedures should not only compensate for the cement thickness (20μm - 40μm) and casting shrinkage of metal but also for the decreased width of the die by using a suitable die relief method. In the single step technique, the small amount of variation in the dimension can be compensated by one coat of die spacer which has been shown to vary from 8μm - 40μm.21

For group II casts, the results showed a decrease in the mesiodistal distances (AB, CD) as compared to the master model varying between 0.1mm to 0.12mm. The faciolingual distances (EF, GH) also showed a decrease in dimension from the master model by 0.14mm. Die 1 and die 2 showed a negligible decrease in height (EI, GJ) by 0.04mm and 0.16mm respectively. Interabutment (KL) distance is decreased by 0.10mm than the master model.

The dies produced were smaller than the master model for all the distances measured. The decrease in the mesiodistal dimension and buccolingual dimension was attributed to the unrestricted polymerization shrinkage of the setting material towards the center of the mass in the interproximal areas.

For group III casts, the results showed a decrease in the mesiodistal distances as compared to the master model varying between 0.02mm and 0.07mm. The faciolingual distance was found to be less than the master model in die 1 (EF) by 0.01mm and increase in die 2 (GH) by 0.02mm. The height of die 1 (EI) and die 2 (GJ) were increased by 0.01mm and 0.03mm respectively. The inter-abutment distances KL between die 1 and die 2 was decrease by 0.01mm.

All the dimensions except for EI and GJ were less compared to master model.

However, even though there was an uneven die size variation, the range of discrepancy from the master model was small. The common observation in group I, II, and III was that the interabutment distance decreased, though there was no statistical significance. For group IV casts, the results showed a decrease in the mesiodistal distances AB, CD as compared to the master model varying between 0.03mm to 0.04mm. The faciolingual distances (EF, GH) showed an increase in dimension from the master model varying between 0.02mm to 0.04mm. The height of die 1 and die 2 (EI) and (GJ) was found to be more than the master model by 0.11mm to 0.09mm respectively. The inter-abutment distances between die 1 and die 2 (KL) was more than the master model by 0.22mm.

In general, the dies produced were oversized for all the distances measured except for mesiodistal measurements. The dimensional variation may have occurred probably due to the higher thickness of light body.

Our findings show that group III (Table 3) produced the most accurate result in the anteroposterior and vertical dimensions, followed by group IV (Table 4) in the anteroposterior dimension, and group II in the vertical dimension. Group I (Table 1) produced the least accurate results in all dimensions.

Table 3: Distance measurements for group III stone model.

Distances mm
AB CD EF GH EI GJ KL
1 6.05129 5.95457 5.95390 6.09805 8.23003 8.00028 27.8785
2 6.02629 6.07012 5.87921 5.91281 7.72664 7.77882 28.1784
3 5.97558 5.94603 6.10066 6.16380 8.07450 8.23214 27.8840
4 5.76936 6.08600 6.04451 6.08952 8.04208 8.11814 27.9617
5 6.00238 5.98876 5.99064 6.01297 8.09023 8.08894 27.9876
6 6.06674 6.09876 5.80982 5.90475 8.00493 8.10020 27.9564
7 5.98947 6.00956 6.00043 6.09474 7.93526 7.97839 27.8990
8 5.90028 5.08764 6.18987 6.06647 8.00385 8.03547 28.0007
9 5.89089 5.96754 5.88986 6.00384 7.89904 8.01435 28.0997
10 6.15544 6.07654 5.93425 6.10001 7.90094 7.99485 27.9954
11 6.03324 6.00934 5.99985 5.99940 8.00036 8.10015 27.9859
12 5.90048 6.00231 5.86758 5.87483 8.16573 7.89905 28.0032
13 5.98867 5.90564 5.99098 5.98894 8.09304 7.99047 28.1023
14 5.95463 5.88976 6.10054 5.99038 7.99040 8.00384 27.9873
15 6.06635 5.90896 6.09087 6.00345 8.00463 8.10023 28.0068

Table 4: Distance measurements for group IV stone models.

Distances mm
AB CD EF GH EI GJ KL
1 5.88921 6.00751 5.99034 6.10381 8.05479 7.86502 28.3966
2 5.86669 6.06570 6.06251 6.08897 8.01298 8.22569 28.4796
3 6.11167 5.93163 6.04262 6.05183 8.10930 7.95410 28.1173
4 6.08278 6.04180 6.08351 6.04203 8.11898 7.93637 28.0348
5 6.19840 6.06647 5.98894 6.04897 8.08825 8.27748 28.1679
6 5.88930 5.96758 5.86849 6.18947 8.19854 8.16748 28.1238
7 5.78890 6.18894 6.00493 6.03748 8.16673 7.98859 28.3659
8 5.90957 5.78836 6.09948 5.98864 8.18594 8.09937 28.2345
9 5.77839 5.89673 6.13382 5.89304 8.05620 8.09485 28.3567
10 6.05793 5.96734 5.88857 6.04483 7.95720 7.96573 28.0986
11 6.12038 5.79304 5.95738 5.89974 8.00937 8.09526 28.1425
12 6.20027 6.12758 6.04563 5.93829 8.26893 8.14536 28.2456
13 5.99046 6.00348 6.19948 5.99904 8.12837 8.29473 28.3675
14 5.78624 5.70037 6.07586 6.17375 8.14676 8.20293 28.1667
15 5.89937 5.87784 5.87738 6.09375 8.11898 7.96674 28.0756

Table 1: Distance measurements for group I stone models.

Distances mm
AB CD EF GH EI GJ KL
1 5.97762 5.85680 6.03572 5.86542 7.97499 7.84307 26.5487
2 5.51052 6.08229 6.17854 5.65311 8.30443 7.98255 28.0624
3 6.06499 5.88732 6.09281 5.80439 8.10035 7.97720 27.9598
4 5.94223 6.27815 5.91990 6.13215 8.12780 8.02439 28.0936
5 5.99032 5.88920 6.18963 6.22320 8.14860 7.94180 27.8210
6 6.18398 6.02243 6.00506 6.00521 8.10339 7.96698 27.7559
7 5.77024 6.11231 6.12365 6.11234 8.22356 7.94350 27.5678
8 5.84735 6.28821 6.00596 6.12654 8.13356 7.84324 26.7786
9 5.90323 6.30111 6.23476 6.20032 8.30454 7.99789 27.6785
10 5.75213 5.88744 5.92234 5.87765 8.14356 7.88243 27.6574
11 5.84567 5.78922 5.93321 5.67843 7.99432 8.01245 26.5649
12 6.02234 5.82342 5.84532 5.78954 7.90450 8.11485 28.0476
13 5.77601 5.89432 6.12332 6.20001 8.20032 8.00234 27.0956
14 5.93422 6.00223 6.17923 5.86543 8.19876 7.98567 27.8830
15 5.83453 5.88733 6.03847 5.97657 8.23467 7.78365 26.6673

The accuracy of group III could be attributed to a controlled amount of bulk of impression material, adhesive systems and low polymerization contraction with the heavy-body material.

Conclusion:

  1. The two step double mix putty wash impression technique with 1mm of spacer yielded casts that showed the least dimensional variation as compared to the single step putty wash impression technique.

  2. One step putty wash impression technique produced casts that showed the greatest dimensional variation in all the distances, compared to all the groups.

Footnotes

Source of Support: Nil

Conflict of Interest: None Declared

Contributor Information

Ramandeep Dugal, Department of Prosthodontics, M A Rangoonwala College of Dental Sciences & Research Centre, Pune, Maharashtra, India.

Bhargavi Railkar, Department of Prosthodontics, M A Rangoonwala College of Dental Sciences & Research Centre, Pune, Maharashtra, India.

Smita Musani, Department of Prosthodontics, M A Rangoonwala College of Dental Sciences & Research Centre, Pune, Maharashtra, India.

References

  • 1.S Caputi, G Varvara. Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step Putty/light-body impression technique: An in vitro study. J Prosthet Dent. 2008;99:274–281. doi: 10.1016/S0022-3913(08)60061-X. [DOI] [PubMed] [Google Scholar]
  • 2.B Marshak, D Assif, R Pilo. A controlled putty-wash impression technique. J Prosthet Dent. 1990;64:635–636. doi: 10.1016/0022-3913(90)90285-k. [DOI] [PubMed] [Google Scholar]
  • 3.N Samet, M Shohat, A Livny, EI Weiss. A clinical evaluation of fixed partial denture impressions. J Prosthet Dent. 2005;94:112–117. doi: 10.1016/j.prosdent.2005.05.002. [DOI] [PubMed] [Google Scholar]
  • 4.SH Hung, JH Purk, DE Tira, JD Eick. Accuracy of one-step versus two-step putty wash addition silicone impression technique. J Prosthet Dent. 1992;67:583–589. doi: 10.1016/0022-3913(92)90151-y. [DOI] [PubMed] [Google Scholar]
  • 5.SY Chen, WM Liang, FN Chen. Factors affecting the accuracy of elastometric impression materials. J Dent. 2004;32:603–609. doi: 10.1016/j.jdent.2004.04.002. [DOI] [PubMed] [Google Scholar]
  • 6.J Nissan, BZ Laufer, T Brosh, D Assif. Accuracy of three polyvinyl siloxane putty-wash impression techniques. J Prosthet Dent. 2000;83:161–165. doi: 10.1016/s0022-3913(00)80007-4. [DOI] [PubMed] [Google Scholar]
  • 7.SM Morgano, P Milot, P Ducharme, L Rose. Ability of various impression materials to produce duplicate dies from successive impressions. J Prosthet Dent. 1995;73:333–340. doi: 10.1016/s0022-3913(05)80327-0. [DOI] [PubMed] [Google Scholar]
  • 8.RG Craig. Review of dental impression materials. Adv Dent Res. 1988;2:51–64. doi: 10.1177/08959374880020012001. [DOI] [PubMed] [Google Scholar]
  • 9.WW Chee, TE Donovan. Fine detail reproduction of very high viscosity polyvinyl siloxane) impression materials. Int J Prosthodont. 1989;2:368–370. [PubMed] [Google Scholar]
  • 10.J Nissan, M Gross, A Shifman, D Assif. Effect of wash bulk on the accuracy of polyvinyl siloxane putty-wash impressions. J Oral Rehabil. 2002;29:357–361. doi: 10.1046/j.1365-2842.2002.00820.x. [DOI] [PubMed] [Google Scholar]
  • 11.WW Chee, TE Donovan. Polyvinyl siloxane impression materials: a review of properties and techniques. J Prosthet Dent. 1992;68:728–732. doi: 10.1016/0022-3913(92)90192-d. [DOI] [PubMed] [Google Scholar]
  • 12.I Lewinstein. The ratio between vertical and horizontal changes of impressions. J Oral Rehab. 1993;20:107–114. doi: 10.1111/j.1365-2842.1993.tb01520.x. [DOI] [PubMed] [Google Scholar]
  • 13.JL Boulton, JP Gage, PF Vincent, KE Basford. A laboratory study of dimensional changes for three elastomeric impression materials using custom and stock trays. Aust Dent J. 1996;41:398–404. doi: 10.1111/j.1834-7819.1996.tb06026.x. [DOI] [PubMed] [Google Scholar]
  • 14.PV Carrotte, A Johnson, RB Winstanley. The influence of the impression tray on the accuracy of impressions for crown and bridge work - an investigation and review. Br Dent J. 1998;185:580–585. doi: 10.1038/sj.bdj.4809870. [DOI] [PubMed] [Google Scholar]
  • 15.RG Craig, WJ O' Brien, JM Powers. Dental Materials: Properties and Manipulation, 11th ed. Maryland, Missouri:Mosby Year Book, Inc. 2002:353–356. [Google Scholar]
  • 16.N Gautam, SM Sajjan. Matrix impression system (MIS) versus conventional putty reline technique (PRT): A comparative evaluation. J Ind Prosthodont Soc. 2003;3:44–48. [Google Scholar]
  • 17.RG Craig, P John. Restorative Dental Materials, 11th ed. Maryland, Missouri:Mosby Inc. 2002:362–365. [Google Scholar]
  • 18.SH Hung, JH Purk, DE Tira, JD Eick. Accuracy of one step verses two step putty wash addition silicone impression technique. J Prosthet Dent. 1992;67:583–589. doi: 10.1016/0022-3913(92)90151-y. [DOI] [PubMed] [Google Scholar]
  • 19.GH Johnson, RG Craig. Accuracy of addition silicones as a function of technique. J Prosthet Dent. 1986;55:197–203. doi: 10.1016/0022-3913(86)90342-2. [DOI] [PubMed] [Google Scholar]
  • 20.Saunders, SW Sharkey, GM Smith, WG Taylor. Effect of WP impression tray design and impression technique upon the accuracy of stone casts produced from a putty-wash polyvinyl siloxane impression material. J Dent. 1991;19:283–289. doi: 10.1016/0300-5712(91)90072-7. [DOI] [PubMed] [Google Scholar]
  • 21.JA Ceyhan, GH Johnson, X Lepe. The effect of tray selection, viscosity of impression material and sequence of pour on the accuracy of dies made from dual arch impression. J Prosthet Dent. 2003;90:143–149. doi: 10.1016/s0022-3913(03)00276-2. [DOI] [PubMed] [Google Scholar]