Applying 21st Century Imaging Technology to Wound Healing: An Avant-Gardist Approach

Frank Lee Bowling 1,2, James Paterson 2, Agbor Ndip 1
PMCID: PMC3876362  PMID: 24124945

Abstract

A significant arising complication in the care of patients with diabetes is increased susceptibility to chronic wounds, including diabetic foot ulcers and pressure sores. This is driven by, e.g., neuropathy and peripheral arterial disease. It is well recognized that best practice in wound care requires wound assessment, including measurement, on presentation and regularly throughout the treatment program. Proper assessment is necessary to ensure that the most appropriate and cost-effective therapy is used at all times, with quantitative measurement necessary to track the efficacy of the chosen approach. A documented assessment can also assist patient–clinician dialog and discussion within the multidisciplinary team. Remote evaluation and assessment of the wound is also of increasing importance and practicality through the use of a telemedicine approach. There has been considerable progress in the space of imaging for wounds, including systems that include three-dimensional measurement and telemedicine features. This literature review examines the available options and reviews the clinical evidence for measurement accuracy, scope for remote assessment, and published user feedback on the systems.

Keywords: diabetic foot, imaging, technology, wound healing, wounds


Foot ulcers are one of the most common complications of diabetes, affecting up to 25% of patients during their lifetime1 and frequently resulting in hospitalization.24

Diabetic foot ulcers are also associated with significant morbidity and mortality,5 with 80% of all diabetes-related lower extremity amputation being preceded by a foot ulcer.6 Together with prevention strategies, proper management must be a mainstay in the approach to curbing the burden associated with foot ulcers.

Accurate recognition and monitoring of ulcer characteristics facilitates benchmarking therapeutic response. Further, if research into new agents/interventions for wound healing should continue to inform practice, it is essential that ulcer characteristics are well defined in order to (i) enable comparison between studies, (ii) determine which patients/ulcers derive the most benefits from a particular therapeutic approach, and (iii) allow accurate monitoring of wound healing in order to guide clinical decision making.

In fact, wound care is a complex and time-consuming process that involves many different disciplines within the foot care continuum. It is well established that best practice in wound care is to perform regular assessment of the wound, including measurement.7 Measurement can inform the clinical decision making process to optimize the therapeutic approach8 and can improve communication between the multidisciplinary team and between clinician and patient. High-quality communication can, in turn, motivate and empower the patient, improving compliance.9 There is also an increasing drive for efficiency in wound care, leveraging technological advances to utilize telemedicine approaches to allow remote assessment and monitoring of wounds.10,11

We have reported on the importance of measurements in a thematic series on diabetic wound healing in general.12 Numerous academic and commercial groups have developed systems aimed at facilitating the goals mentioned earlier. A major component of many of these systems is to provide tools to facilitate the accurate and repeatable measurement of wounds; it is well understood that this can be time-consuming and ultimately inaccurate using conventional means, e.g., a ruler or tracing paper and “depth probe.”13 Typically, the process involves computerized image capture and processing, then input of data, demarcation of wounds, and so forth in order to generate measurements and health records. These systems typically center around the use of a bespoke clinical imaging device; however, with the burgeoning smartphone economy, there have also been several applications (apps) developed for this space.

Methods

In this nonsystematic review, the clinical evidence underpinning the most significant of the wound imaging systems available is reviewed. Three main evidence areas are considered:

  1. Measurement accuracy. Has the measurement capability of the system been clinically validated by comparing measurements “like-for-like” with conventional measurements?

  2. Potential for remote assessment. Has the potential for the system to be deployed in a remote assessment context been examined, and is there supporting evidence or case studies?

  3. User feedback on system efficacy. To what extent have external parties used and benefited from the system and provided feedback on use in practice?

In addition to clinical evidence, it is also useful to consider the feature set of the system, with the most critical features being

  • Two-dimensional (2D) or three-dimensional (3D) imaging. To perform measurements of, e.g., wound volume, a 3D image map of the wound is required. This is technically challenging, and many systems instead provide measurements based on 2D images (a planimetric approach).

  • Electronic data capture. Some systems support data capture beyond imaging and measurement, moving toward an electronic medical record (EMR) type application. This may be useful if the clinical site does not already have such a system.

  • Networking and interfacing. In a collaborative hospital environment, it is important that the images and measurements acquired with the system can be shared and reviewed throughout the clinical team. It may also be beneficial to clinician workflow to integrate with existing EMR systems.

Results

Perhaps the most well-known system is the Aranz Silhouette (Aranz Medical, Christchurch, New Zealand). Two versions of the system exist; the first is a handheld unit based on a portable data assistant with a camera and laser striping attachment (SilhouetteMobile), and the second, later-released offering is a bespoke tethered device akin to a webcam, with a more advanced laser striping system (SilhoutteStar). The system provides 2D color images with correction for distance, skew, and shape based on analysis of projected laser stripes. The Silhouette system supports detailed EMR keeping and integration with third-party electronic systems through the SilhoutteCentral server product. There is a good quantity of clinical evidence both on measurement accuracy1417 and system efficacy18,19 for the Silhouette system.

The measurement of area and volume instrument system was originally developed at the University of Glamorgan in 1988. It is now in its third hardware iteration and marketed as the 3D LifeVis (Quantificare, Nice-Sophia Antipolis, France). The system consists of an imaging device (either fully bespoke or based on an off-the-shelf camera) and provides a fully 3D color representation of the wound from which a variety of measurements, including volume, can be taken. Using an array of mirrors and lenses, two laterally displaced images are first obtained and then reconstructed into a 3D image. There have been numerous clinical and technical publications around measurement accuracy.2023 However, data on remote assessment and user feedback are less available. Nonetheless, it is a portable and user-friendly system.

The Eykona Wound Measurement System (Eykona Medical, Oxford, England) uses a bespoke imaging device with single-use disposable targets to acquire data. The system provides a fully 3D color representation of the wound with a wide variety of measurement tools, including a form of color analysis. The system is known to support networked operation with basic data export to third-party EMR systems. Several credible publications exist on this system’s measurement accuracy in well-known journals,24,25 and a preliminary investigation into the accuracy of remote assessment supports the potential for the system to be used for telemedicine.25 In this article, remote assessment is the validation of clinically relevant observations made from a remote view of 3D wound images. At least one published paper examines clinician and patient feedback on the system, in the context of healing wounded soldiers.26 There are also several examples of the system being used beyond wounds, for example, quantifying inflammation due to tattooing27 and scarring.28

Wound Zoom (Wound Zoom, CO) uses a bespoke handheld imaging device with projected laser dots alongside a camera sensor to acquire a 2D image with depth and skew correction. Evidence of measurement accuracy can be found in the work of Nemeth and coauthors.29 There is presently a lack of clinical publications supporting other aspects of the system. Wound Zoom supports portable document format output, which may allow basic integration with third-party systems.

PictZar (BioVisual Technologies, LLC, NJ) is wound measurement software that can perform planimetry on 2D digital images acquired with a scale available in the image. The images themselves can be acquired with any digital camera and then loaded into the software. Measurements acquired using the system have been validated, including inter-rater reliability;30 user experience is also documented. The system supports exports of reports, including pressure ulcer scale for healing score, which may facilitate integration with third-party systems.

In addition to the dedicated clinical imaging systems mentioned here, there are also several examples of general-purpose 3D imaging systems being used to measure wounds.31,32 The Next Engine Laser Scanner HD (NextEngine Inc., CA) has been demonstrated to have application in the assessment of cutaneous leishmaniasis wounds.32 The Konica Minolta Vivid 910 (Konica Minolta, Tokyo, Japan)33 and Polhemus FastSCAN (Aranz, Christchurch, New Zealand) have similarly been shown to be of use in imaging and measurement of wounds.34 The generalist 3D imaging space has a continual drive for decreased cost and improved image quality, making these systems increasingly attractive for the wound measurement application. However, there is not as yet an “off-the-shelf” clinical wound measurement solution available for use with these hardware platforms.

Finally, a review of smartphone app stores reveals a number several smartphone applications aimed at imaging and measuring wounds. Of these, Mobile Wound Analyzer (Health Path Srl, Rome, Italy) appears the most capable and best supported. It claims planimetric measurement capability based on having a scale in the image and the ability to determine tissue type in the wound bed (necrotic, fibrinous, and granulation). Presently there does not appear to be any published clinical evidence to support these claims.

Conclusion

Accurate, reliable, reproducible measurements have been important cornerstones in medical practice used in objective assessment and benchmarking success. Accurate determination of ulcer size is widely accepted as an indication of wound closure and, thus, of wound healing. While ruler and hand-tracing methods are simple to use, they are limited by the subjectivity of the point-of-care assessor. The newer digital methods and optical systems that have been evaluated still require clinician input to demark wound boundaries for measurement; however, they can then automate higher-order metrics, such as wound area and volume. These systems also offer an opportunity to reduce intraobserver bias, as a single clinical expert can perform the markup on data collected by potentially many different clinicians at the point of care.

It is evident that wound imaging with clinically validated measurement can be beneficial to the healing process. Continual technical improvements, alongside the burgeoning clinical evidence, suggest that eventually these techniques will be commonplace and accepted as the standard. Telemedicine, facilitated by electronic imaging and measurement systems as described in this article, has great potential to reduce cost and improve standards in wound care; this derives from reducing patient and clinician transport and providing higher-level and more immediate access to expert clinical knowledge. However, while several existing commercial products, notably the Aranz and Eykona systems, have a reasonable body of associated clinical evidence, the pace of technological development means the field remains rapidly changing; the authors are aware of several groups active in this area of research.31,35,36 As yet, no system has demonstrated widespread adoption in routine clinical use.

Glossary

(2D)

two-dimensional

(3D)

three-dimensional

(app)

application

(EMR)

electronic medical record

Disclosure

James Paterson is an employee, director, and shareholder of Eykona Medical Ltd.

References

  • 1.Singh N, Armstrong DG, Lipsky BA. Preventing foot ulcers in patients with diabetes. JAMA. 2005;293(2):217–228. doi: 10.1001/jama.293.2.217. [DOI] [PubMed] [Google Scholar]
  • 2.Armstrong DG, Lavery LA, Quebedeaux TL, Walker SC. Surgical morbidity and the risk of amputation due to infected puncture wounds in diabetic versus nondiabetic adults. J Am Podiatr Med Assoc. 1997;87(7):321–326. doi: 10.7547/87507315-87-7-321. [DOI] [PubMed] [Google Scholar]
  • 3.Goldner MG. The fate of the second leg in the diabetic amputee. Diabetes. 1960;9:100–103. doi: 10.2337/diab.9.2.100. [DOI] [PubMed] [Google Scholar]
  • 4.Lavery LA, Ashry HR, van Houtum W, Pugh JA, Harkless LB, Basu S. Variation in the incidence and proportion of diabetes-related amputations in minorities. Diabetes Care. 1996;19(1):48–52. doi: 10.2337/diacare.19.1.48. [DOI] [PubMed] [Google Scholar]
  • 5.Winkley K, Stahl D, Chalder T, Edmonds ME, Ismail K. Risk factors associated with adverse outcomes in a population-based prospective cohort study of people with their first diabetic foot ulcer. J Diabetes Complications. 2007;21(6):341–349. doi: 10.1016/j.jdiacomp.2007.09.004. [DOI] [PubMed] [Google Scholar]
  • 6.Boulton AJ, Vileikyte L, Ragnarson-Tennvall G, Apelqvist J. The global burden of diabetic foot disease. Lancet. 2005;366(9498):1719–1724. doi: 10.1016/S0140-6736(05)67698-2. [DOI] [PubMed] [Google Scholar]
  • 7.Flanagan M. Wound measurement: can it help us to monitor progression to healing? J Wound Care. 2003;12(5):189–194. doi: 10.12968/jowc.2003.12.5.26493. [DOI] [PubMed] [Google Scholar]
  • 8.Oyibo SO, Jude EB, Tarawneh I, Nguyen HC, Armstrong DG, Harkless LB, Boulton AJ. The Effects of ulcer size and site, patient’s age, sex and type and duration of diabetes on the outcome of diabetic foot ulcers. Diabet Med. 2001;18(2):133–138. doi: 10.1046/j.1464-5491.2001.00422.x. [DOI] [PubMed] [Google Scholar]
  • 9.Gethin GT, Cowman S. Wound measurement: the contribution to practice. EWMA J. 2007;7(1):26–28. [Google Scholar]
  • 10.Ratlif CR, Forch W. Telehealth for wound management in long-term care. Ostomy Wound Manage. 2005;51(9):40–45. [PubMed] [Google Scholar]
  • 11.Jennett PA, Afeck Hall L, Hailey D, Ohinmaa A, Anderson C, Thomas R, Young B, Lorenzetti D, Scott RE. The socio-economic impact of telehealth: a systematic review. J Telemed Telecare. 2003;9(6):311–320. doi: 10.1258/135763303771005207. [DOI] [PubMed] [Google Scholar]
  • 12.Ndip A, Jude EB. Diabetic foot disease and wound healing. In: Mani R, Romanelli M, Shukla V, editors. Measurements in wound healing: science and practice. 1st. London: Springer-Verlag; 2012. pp. 17–38. [Google Scholar]
  • 13.Majeske C. Reliability of wound surface area measurements. Phys Ther. 1992;72(2):138–141. doi: 10.1093/ptj/72.2.138. [DOI] [PubMed] [Google Scholar]
  • 14.Nixon D, Philps A, Jonsson L, Nixon M. Measurement of diabetic foot ulcers using SilhouetteMobile. J Wound Technol. 2009;3:37–38. [Google Scholar]
  • 15.Nixon MA, Davey BK, Fright WR, McCallum BC, Kieser DC. Finland: European Wound Management Association Congress (EWMA), Helsinki; 2009. A comparison of the measurement accuracy of an electronic, hand-held wound measurement system with acetate tracing. [Google Scholar]
  • 16.Nixon M, Rivett T, Robinson B. Atlanta, GA: Symposium for Advanced Wound Care (SAWC); 2012. Assessment of accuracy and repeatability on wound models of a new hand-held, electronic wound measurement device. [Google Scholar]
  • 17.Hammond CE, Nixon MA. The reliability of a handheld wound measurement and documentation device in clinical practice. J Wound Ostomy Continence Nurs. 2011;38(3):260–264. doi: 10.1097/WON.0b013e318215fc60. [DOI] [PubMed] [Google Scholar]
  • 18.Filetcher J. The use of electronic data capture devices in wound care settings. Wounds UK. 2012;8(4):119–122. [Google Scholar]
  • 19.Romanelli M, Dini V, Rogers L, Hammond C, Nixon M. Clinical evaluation of a wound measurement and documentation system. Wounds. 2008;20(9):256–264. [PubMed] [Google Scholar]
  • 20.Plassmann P. MAVIS-II development: a progress report. Med Phys Engineer Wales. 1999 [Google Scholar]
  • 21.Plassmann P. Measuring wounds. J Wound Care. 1995;4(6):269–272. doi: 10.12968/jowc.1995.4.6.269. [DOI] [PubMed] [Google Scholar]
  • 22.Plassmann P, Jones CD, McCarthy M. Accuracy and precision of the hand-held MAVIS wound measurement device. Int J Lower Extrem Wounds. 2007;6(3):176–190. [Google Scholar]
  • 23.Davis AJ, Nishimura J, Seton J, Goodman BL, Ho CH, Bogie KM. Repeatability and clinical utility in stereophotogrammetric measurements of wounds. J Wound Care. 2013;22(2):90–92. 94–97. doi: 10.12968/jowc.2013.22.2.90. [DOI] [PubMed] [Google Scholar]
  • 24.Bowling FL, King L, Fadavi H, Paterson JA, Preece K, Daniel RW, Matthews DJ, Boulton AJ. An assessment of the accuracy and usability of a novel optical wound measurement system. Diabet Med. 2009;26(1):93–96. doi: 10.1111/j.1464-5491.2008.02611.x. [DOI] [PubMed] [Google Scholar]
  • 25.Bowling FL, King L, Paterson JA, Hu J, Lipsky BA, Matthews DR, Boulton AJ. Remote assessment of diabetic foot ulcers using a novel wound imaging system. Wound Repair Regen. 2011;19(1):25–30. doi: 10.1111/j.1524-475X.2010.00645.x. [DOI] [PubMed] [Google Scholar]
  • 26.Savage JM, Jefery SLA. Use of 3D photography in complex-wound assessment. J Wound Care. 2013;22(3):156, 158–160. doi: 10.12968/jowc.2013.22.3.156. [DOI] [PubMed] [Google Scholar]
  • 27.Butcher M, White R. Wounds UK: Harrogate; 2012. Using a 3-D imaging system to monitor tissue response following minor partial-thickness skin trauma. [Google Scholar]
  • 28.Hallam MJ, McNaught K, Thomas AN, Nduka C. A practical and objective approach to scar colour assessment. J Plast Reconstr Aesthet Surg. 2013 doi: 10.1016/j.bjps.2013.06.021. Epub ahead of print. [DOI] [PubMed] [Google Scholar]
  • 29.Nemeth M, Sprigle S, Gajjala A. Clinical usability of a wound measurement device. 36th Annual American Spinal Injury Conference; Nashville, TN. 2010. [Google Scholar]
  • 30.Wendelken M, Berg WT, Lichtenstein P, Markowitz L, Comfort C, Alvarez OM. Wounds measured from digital photographs using photodigital planimetry software: validation and rater reliability. Wounds. 2011;23(9):267–275. [PubMed] [Google Scholar]
  • 31.Treuillet S, Albouy B, Lucas Y. Three-dimensional assessment of skin wounds using a standard digital camera. IEEE Trans Med Imaging. 2009;28(5):752–762. doi: 10.1109/TMI.2008.2012025. [DOI] [PubMed] [Google Scholar]
  • 32.Zvietcovich F, Castaneda B, Valencia B, Llanos-Cuentas A. A 3D assessment tool for accurate volume measurement for monitoring the evolution of cutaneous leishmaniasis wounds. Conf Proc IEEE Eng Med Biol Soc. 2012. 2012:2025–2028. doi: 10.1109/EMBC.2012.6346355. [DOI] [PubMed] [Google Scholar]
  • 33.Hani AF, Eltegani NM, Hussein SH, Jamil A, Gill P. Assessment of ulcer wounds size using 3D skin surface imaging. Proceedings of the 1st International Visual Informatics Conference on Visual Informatics. 2009:243–253. [Google Scholar]
  • 34.Liu X, Kim W, Schmidt R, Drerup B, Song J. Wound measurement by curvature maps: a feasibility study. Physiol Meas. 2006;27(11):1107–1123. doi: 10.1088/0967-3334/27/11/005. [DOI] [PubMed] [Google Scholar]
  • 35.Kecelj-Leskovec N, Jezersek M, Mozina J, Pavlović MD, Lunder T. Measurement of venous leg ulcers with a laser-based three-dimensional method: comparison to computer planimetry with photography. Wound Repair Regen. 2007;15(5):767–771. doi: 10.1111/j.1524-475X.2007.00300.x. [DOI] [PubMed] [Google Scholar]
  • 36.Callieri M, Cignoni P, Coluccia M, Pingi P, Romanelli M, Scopigno R. Derma: monitoring the evolution of skin lesions with a 3D system. 8th International Fall Workshop on Vision, Modelling, and Visualization. 2003 [Google Scholar]

Articles from Journal of Diabetes Science and Technology are provided here courtesy of Diabetes Technology Society

RESOURCES