Utility of an open field Shack-Hartmann aberrometer for measurement of refractive error in infants and young children

Erin M Harvey a,b, Joseph M Miller a,b,c, Jim Schwiegerling a,c
PMCID: PMC3881277  NIHMSID: NIHMS530660  PMID: 24160970

Abstract

PURPOSE

To assess the utility of an open-field Shack-Hartmann aberrometer for measurement of refractive error without cycloplegia in infants and young children.

METHOD

Data included 2698 subject encounters with Native American infants and children aged 6 months to <8 years. We attempted right eye measurements without cycloplegia using the pediatric wavefront evaluator (PeWE) on all participants while they viewed near (50 cm) and distant (2 m) fixation targets. Cycloplegic autorefraction (Rmax [Nikon Retinomax K-plus2]) measurements were obtained for children aged ≥3 years.

RESULTS

The success rates of noncycloplegic PeWE measurement for near (70%) and distant targets (56%) significantly improved with age. Significant differences in mean spherical equivalent (M) across near versus distant fixation target conditions were consistent with the difference in accommodative demand. Differences in astigmatism measurements for near versus distant target conditions were not clinically significant. Noncycloplegic PeWE and cycloplegic Rmax measurements of M and astigmatism were strongly correlated. Mean noncycloplegic PeWE M was significantly more myopic or less hyperopic and astigmatism measurements tended to be greater in magnitude compared with cycloplegic Rmax.

CONCLUSIONS

The PeWE tended to overestimate myopia and underestimate hyperopia when cycloplegia was not used. The PeWE is useful for measuring accommodation and astigmatism.


Cycloplegic retinoscopy is considered the gold standard for measuring refractive errors in infants and young children. However, an objective instrument that would accurately measure refractive error in infants and toddlers without cycloplegia would be of great value. While traditional tabletop autorefractors are generally not suitable because of their stationary design and their close working distance,1,2 there has been some success in estimating refractive error in infants and young children using handheld instruments.237 Measurements in children without cycloplegia often show “instrument myopia,” that is, an underestimation of hyperopia or overestimation of myopia because of accommodation.6,9,10,14,16,25,2932,38,39 Instrument designers have attempted to deal with this issue by using “non-accommodative” fixation targets, by incorporating a fogging mechanism, or by using a correction factor in estimation of spherical refractive error. However, these methods do not consistently relax accommodation in children. Since accommodation is often variable, applying a simple correction factor has a limited effect on increasing accuracy. One study reported less minus overcorrection in noncycloplegic autorefraction of primary school children using an autorefractor with an open-field design and distant target.39

The pediatric wavefront evaluator (PeWE) is a prototype handheld open-field Shack–Hartmann aberrometer designed to measure refractive error in infants and young children without cycloplegia. The open-field design has been shown to provide measurements with less minus over-correction in children.39 The PeWE also features continuous video capture, which increases the likelihood of acquiring centered and well-focused wavefront images for analysis. Its handheld design allows flexibility in aligning the instrument with a young child’s eyes while the child views a target through the instrument. The purpose of the present study was to assess (1) feasibility of obtaining measurements in infants and young children by evaluating the instrument’s success rate across age in children aged 6 months to <8 years, (2) effectiveness of the open-field design for relaxation of accommodation by comparing non-cycloplegic PeWE measurements of spherical equivalent (M) while children viewed near versus distant fixation targets, and (3) accuracy of noncycloplegic PeWE measurements compared with cycloplegic autorefraction.

Methods and Subjects

Subjects were children aged 6 months to <8 years who participated in a longitudinal study of refractive development between January 2007 and May 2010. The present study includes secondary analyses of PeWE measurements that were collected as part of a larger study of refractive development in order to measure higher-order aberrations and accommodation. The majority of subjects were members of the Tohono O’odham Nation, who have a high prevalence of astigmatism that is present in infancy and persists through grade school.37,4044 Children were recruited from the Women, Infants and Children clinics, from the Tohono O’odham Early Childhood Head Start Program, from the Tohono O’odham community, and from kindergarten and first grade classrooms on the Tohono O’odham reservation. Follow-up was attempted yearly until either the child completed the first grade or the study ended (May 2010). This study was approved by the Tohono O’odham Nation and the Institutional Review Board of the University of Arizona and conformed to the requirements of the US Health Insurance Portability and Accountability Act of 1996. Parents provided written informed consent prior to testing.

Apparatus and Data Processing

The design of the PeWE (Figure 1) is a variation of the Shack–Hartmann system previously described by Straub et al.45 The PeWE is built around a large acrylic window that allows the subject to view real world targets binocularly. It was designed to allow the examiner to slip the window in front of the child’s eyes for measurement while the child views a fixation target with minimal distraction from the target. The window is coated to transmit visible light and reflect infrared light. An infrared superluminescent diode of wavelength 830 nm is collimated and projected into the eye of the subject to create a spot nominally on the retina. Light scattered from the retina encodes the ocular aberrations and emerges from the eye. This light is captured by the PeWE optics and relayed to a lenslet array (Part 0300-7.6-S, Adaptive Optics Associates, Cambridge, MA; 300 mm diameter, 7.6 mm focal length). The spot pattern created by the lenslet array is captured and analyzed with custom software to recover low- and high-order aberrations of the eye. A report on accuracy and validity of the PeWE with simulated refractive errors is provided in e-Supplement 1 (available at jaapos.org).

FIG 1.

FIG 1

The PeWE is used to measure refractive error in a preschool child as she views a cartoon on a laptop computer.

Output video from the instrument is captured on a laptop computer for each subject encounter. After testing, the video (audio video interleave) file is converted to individual bitmap image files, which are manually reviewed for quality. The images deemed centered and in-focus (Figure 2) are then put through an automated processing program that analyzes each image and provides measurements of refractive error in the form of power vectors M (spherical equivalent), J0 (astigmatism in the horizontal or vertical meridian [90°/180°]), and J45 (astigmatism in the oblique meridian [45°/135°]).4648 For each encounter, mean and median M, J0, and J45 across images, as well the number of images used for processing, are output to a spreadsheet. Encounters on which at least 7 images were obtained were considered “successful” and acceptable for further analysis (see e-Supplement 2, available at jaapos.org, for a detailed report on determination of the minimum number of images necessary for valid measurement).

FIG 2.

FIG 2

The videos from each encounter/condition are processed to extract individual images. Images are manually reviewed, and in-focus centered images, as shown in the figure, are selected for analysis. An automated program is used to analyze the images to determine refractive error.

Noncycloplegic PeWE measurements were attempted on all children. Children aged 3 years and older also completed cycloplegic PeWE and cycloplegic autorefraction using the Retinomax K-plus2 (Rmax [Nikon Inc, Melville, NY]), which provides accurate and reliable measurements of refractive error in children.9 Right eye measurements were obtained in a dimly lit room whenever possible.

Noncycloplegic PeWE

Younger children sat on a parent’s lap and older children sat on a chair by themselves. Children were asked to view a fixation target at 50 cm (near) or 2 m (distance), with testing order counterbalanced across subjects. The target was an animated cartoon screensaver displayed on a tablet computer (visual angle 17.3° × 22.7° at 50 cm, 4.4° × 6.0° at 2 m).

The examiner initiated video capture by pressing a key on a laptop computer. While standing to the side of the child, the examiner placed the instrument in front of and below the child’s line of sight, directed the child’s attention to the fixation target, and gradually raised the PeWE until the child was viewing the target through the window. The examiner monitored the image quality in real time through video displayed on the laptop computer and adjusted the position of the PeWE to achieve centered and focused video images. The video capture was terminated when the examiner judged that centered in-focus video had been obtained, or when the child was no longer cooperative. The target was then moved to the second target location, and testing proceeded in the same manner.

Cycloplegic Autorefraction and Cycloplegic PeWE

Cycloplegia was achieved with 1 drop proparacaine 0.5% followed by 2 drops of cyclopentolate 1%. Measurements were obtained using both the Rmax and PeWE at least 30 minutes after administration of eye drops. The examiner attempted to obtain Rmax measurements with a confidence of at least 8, per manufacturer recommendations. PeWE measurements under cycloplegia were only obtained with the target at one distance (2 m).

Results

A total of 2841 subject encounters (data collection points) for 1425 subjects were conducted, with some subjects participating at more than one age and therefore contributing data for more than one encounter. Data from 143 encounters were excluded because PeWE measurement was not obtained because of a technical problem with the instrument (eg, instrument out of alignment or instrument and data files damaged because of vandalism). For the remaining 2698 encounters (1403 subjects with 518, 526, 308, and 51 subjects contributing data for 1, 2, 3, and 4 encounters, respectively), mean age at time of measurement was 4.14 years (SD 2.05).

Noncycloplegic PeWE

Results of noncycloplegic measurements with the PeWE are shown in Table 1. Measurement success for near targets was 70%; for distance targets, 56%. Success rates increased significantly with age for both near and distance (χ2 test; P < 0.001). Analyses conducted within each age group, indicated that the success rate was significantly higher at near than at distance (P < 0.001).

Table 1.

Measurement success rates by age for near and distant target conditions

Age group Sample
size for
age group
Percent of age
group successful
with near
target (n)
Percent of age
group successful
with distant
target (n)
<1 y 206 60.2% (124) 46.1% (95)
1 to <2 y 306 60.5% (185) 53.3% (163)
2 to <3 y 363 61.7% (224) 51.8% (188)
3 to <4 y 391 70.6% (276) 52.4% (205)
4 to <5 y 397 71.3% (283) 53.4% (212)
5 to <6 y 426 77.9% (332) 59.6% (254)
6 to <7 y 403 76.4% (308) 59.1% (238)
7 to <8 y 206 81.6% (168) 72.8% (150)
Total 2698 70.4% (1900) 55.8% (1505)

Results from the 1362 encounters at which successful near and distant target condition noncycloplegic PeWE measurements were obtained are summarized in Table 2. Near versus distance measurements of M, J0, and J45 were strongly correlated (P < 0.001). However, t tests indicated significant differences across near versus distance in mean measurements of M, J0, and J45 (P < 0.001 for M and J0, P < 0.02 for J45).

Table 2.

Comparison of noncycloplegic PeWE near and distant target condition measurements for encounters on which both measurements were obtained

Measure Target condition Mean, D SD Std error mean Mean difference SD of difference Correlation (r2)
M Near −1.26 0.98 0.03 −1.05a 0.73 0.52a
Distant −0.21 0.91 0.02
J0 Near 0.78 0.64 0.02 0.06a 0.28 0.81a
Distant 0.72 0.61 0.02
J45 Near −0.18 0.33 0.01 −0.01a 0.21 0.61a
Distant −0.16 0.29 0.01
a

Statistically significant.

Agreement between near and distance noncycloplegic PeWE measurements by age is summarized in Table 3. There were significant effects of age on agreement for M (P < 0.002) and J0 (P < 0.03) (effect neared significance for J45, P < 0.07). Post hoc comparisons with Bonferroni correction indicated that 1 to <2-year-olds showed significantly less change in M from near to distance fixation than 3 to <4, 4 to <5, and 5 to <6-year-olds (Ps < 0.04). There was also a trend toward greater variability (SD) in 1 to <2-year-olds. Post hoc comparisons yielded no significant differences across age groups for agreement (near verses distance) in J0 and J45 measurements.

Table 3.

Comparison of noncycloplegic PeWE near and distant target condition measurements by age group

Difference in M Difference in J0 Difference in J45



Age N Mean SD Mean SD Mean SD
<1 y 80 −0.93 0.77 0.06 0.32 0.00 0.24
1 to <2 y 141 −0.85 0.97 0.09 0.32 −0.02 0.22
2 to <3 y 163 −0.97 0.79 0.06 0.34 −0.04 0.22
3 to <4 y 189 −1.12 0.68 0.09 0.27 0.01 0.18
4 to <5 y 195 −1.18 0.64 0.09 0.31 0.01 0.20
5 to <6 y 238 −1.09 0.62 0.05 0.23 0.00 0.22
6 to <7 y 218 −1.09 0.66 0.01 0.25 −0.04 0.21
7 to <8 y 138 −1.04 0.73 0.04 0.24 −0.04 0.17
Total 1362 −1.05 0.73 0.06 0.28 −0.01 0.21

Noncycloplegic PeWE versus Cycloplegic Rmax

Results are shown in Table 4 for the 966 encounters where successful results were obtained for near and distance noncycloplegic PeWE and cycloplegic Rmax. PeWE measurements (for both near and distance) were significantly correlated with Rmax measurements (P < 0.001 for M, J0, and J45). However, t tests comparing mean values for PeWE near and distance fixation to those for the Rmax yielded significant differences in M, J0 and J45 (P < 0.001). The PeWE tended to overestimate myopia or underestimate hyperopia by about 1.00 D at distance and 2.00 D at near, and it tended to over-estimate both J0 and J45.

Table 4.

Comparison of noncycloplegic PeWE measurements (near and distant target conditions) to cycloplegic Rmax measurements for encounters on which all 3 measurements were obtained

Measure Instrument/condition Mean SD Mean difference from cRmax SD of difference Correlation with cRmax (r)
M Rmax 0.80 1.05
PeWE, near fixation −1.25 0.95 2.05 1.01 0.50
PeWE, distance fixation −0.15 0.82 0.94 0.85 0.61a
J0 Rmax 0.50 0.57
PeWE, near fixation 0.78 0.67 −0.28a 0.31 0.88a
PeWE, distance fixation 0.72 0.64 −0.23a 0.31 0.87a
J45 Rmax 0.00 0.22
PeWE, near fixation −0.17 0.33 0.17a 0.48 −0.45a
PeWE, distance fixation −0.16 0.29 0.16a 0.44 −0.46a

Rmax, cycloplegic autorefraction using the Retinomax K-plus2; PeWE, noncycloplegic pediatric wavefront evaluator.

a

Statistically significant, P < 0.001.

Separate repeated measures analyses of variance for M, J0, and J45 data were conducted to assess accuracy of PeWE at near and distance by age group (Table 5). There were significant main effects of age at both near (P < 0.04) and distance (P < 0.05). However, post hoc comparisons with Bonferroni correction yielded a significant difference in accuracy only for distance results between the 5 to <6 years and the 6 to <7 years age groups.

Table 5.

Summary of agreement between noncycloplegic PeWE (near and distant target conditions) and cycloplegic Rmax by age group

Comparison Age N Mean difference SD
Rmax vs PeWE with near target 3 to <4 y 185 2.03 0.99
4 to <5 y 193 2.16 1.02
5 to <6 y 234 2.15 0.91
6 to <7 y 216 1.88 1.07
7 to <8 y 138 2.02 1.03
Total 966 2.05 1.01
Rmax vs PeWE with distant target 3 to <4 y 185 0.91 0.86
4 to <5 y 193 0.97 0.86
5 to <6 y 234 1.05 0.81
6 to <7 y 216 0.81 0.87
7 to <8 y 138 0.98 0.89
Total 966 0.94 0.85

Rmax, cycloplegic autorefraction using the Retinomax K-plus2; PeWE, noncycloplegic pediatric wavefront evaluator.

Discussion

The present study provides data regarding the feasibility of examining infants and toddlers without cycloplegia using an autorefractor or vision screener with the general design of the PeWE. Our success rates for near (70%) and distance (56%) fixation are less than ideal; furthermore, success rates may have been elevated because of the fact that many children participated on more than one occasion and may have been more cooperative as they became more familiar with the PeWE. And whereas the success rates for the present study are comparable to those reported for two previous large population-based studies with respect to infants tested by the Retinomax, they were poorer than the success rates for toddlers and young children.2,20

Several strategies could be implemented to increase measurement success. Testers had to judge, based on real-time monitoring of the video, whether or not they were obtaining sufficient data during testing. Providing testers with more precise feedback regarding data quality during the measurement process might improve success rates. Other strategies entail modifying the target design and testing environment. Success rates were lower for measurement at distance. Many children may have had difficulty seeing the target at distance because of astigmatism-related blur and the smaller visual angle of the stimulus. Children may have also been more vulnerable to distraction when the target was at distance. A more salient and attractive target is likely to improve subject cooperation with regard to fixation.

Second, we evaluated the usefulness of the PeWE open-field design in relaxing accommodation in order to obtain valid measurements of refractive error in the absence of cycloplegia. If hyperopic subjects were accurately accommodating, we would expect mean M to be −2.00 for the 50 cm target and −0.50 for the 2 m target, that is, a 1.50 D difference in accommodative demand between the two conditions. Mean values of M were generally consistent with the difference in accommodative demand to the near versus the distant targets (−1.25 D for near [0.75 D accommodative lag] and −0.15 for distance [0.35 D accommodative lag]). Thus subjects tended to underaccommodate to the targets, but the PeWE was able to measure changes of accommodation in response to near versus distance targets (1.10 D change measured with 1.50 D change in accommodative demand). Some of the underaccommodation observed may have been because of the inclusion of myopic children who were unable to focus near targets by accommodating. However, this would likely have had a minimal effect on the results because only 18 (1.8%) of 966 subjects with Rmax data in addition to near and distance PeWE measurements (ie, children aged ≥3 years) had a myopic spherical equivalent ≥1.50 D per Rmax. Analyses examining effects of age indicated that 1 to <2-year-olds showed significantly less change in M, that is, less change in accommodation, from near to distance fixation than did 3- to <6-year-olds. There was also a trend toward greater variability (SD) in this age group. These findings are consistent with our observations that children in this age range are often distracted and less cooperative. We were initially concerned that subjects might look at the beamsplitter of the PeWE, rather than through the PeWE window, thus overaccommodating. The results suggest that this was not the case, as subjects tended to underaccommodate. Finally, results indicated that differences in measurements of astigmatism at near versus at distance were not clinically significant and did not vary by age. This was expected, as accommodation typically has only a small influence on measurements of astigmatism,4953 although changes in astigmatism with accommodation have been reported.54

Overall, results comparing measurements obtained for near versus distant target conditions suggest that the PeWE without cycloplegia might be useful for assessment of accommodation and astigmatism in infants and young children.

Our final assessment examined accuracy of the noncycloplegic PeWE for near and distant fixation target conditions compared with cycloplegic Rmax measurements in children age 3 to <8 years of age. Analysis of M data indicated that PeWE tended to overestimate myopia or underestimate hyperopia by about 1.00 D at distance and 2.00 D at near. The high correlation between noncycloplegic PeWE and cycloplegic Rmax measurements of M indicate that the PeWE provides valid measurements, and with the properly selected cutoff values, may be useful for screening for significant spherical refractive errors.55 However, in its present form and using the procedures outlined here, it is limited in its ability to accurately measure magnitude of spherical refractive error without cycloplegia. Reducing peripheral distraction and revising the nature of the fixation target may result in more reliable relaxation of accommodation and more accurate measurements. For example, research suggests that binocular targets receding into the distance result in maximum relaxation of accommodation.56

Compared to Rmax with cycloplegia, PeWE without cycloplegia tended to overestimate both J0 (about 0.25 D) and J45 (about 0.17 D), but these effects were small and of minimal clinical significance. This is consistent with the results of a previous study in which we found little difference between cycloplegic and non-cycloplegic measures of astigmatism in this population.9

The present study has several limitations. First, the study population had a high prevalence of with-the-rule astigmatism. Second, the instrument under study is not commercially available and in its current form requires significant data processing in order to provide estimates of refractive error (eg, analysis of the data required manual review of thousands of images). Third, an optimal study design would have compared PeWE to the gold standard for infants and toddlers, that is, cycloplegic retinoscopy. However, these data were collected as part of a longitudinal study in which we used Rmax to measure refractive error to ensure consistency in measurements across children and over time and because a previous study of this population established the validity of Rmax measurements.9

In conclusion, the PeWE is prone to “instrument myopia” when measuring non-cyclopleged children. However, it does seem to accurately reflect changes in accommodation from distance to near targets without cycloplegia, which may prove to be useful in the objective assessment of accommodation in infants and young children. In order to improve the utility of the PeWE, further work is needed to develop software that will automatically score data and testing procedures that will increase measurement success rates and maximize relaxation of accommodation during measurement.

Supplementary Material

1
2

Acknowledgments

The authors thank the Tohono O’odham Nation, the Tohono O’odham Early Childhood Head Start Program, the Baboquivari School District, the Bureau of Indian Affairs Office of Indian Education Programs, the San Xavier Mission School, and our National Institutes of Health/National Eye Institute Data Monitoring and Oversight Committee [Robert Hardy, PhD (Chair), Tina Aguilar, Donald Everett, MA, Jeanette Francisco, Jonathan Holmes, MD, Ronald Johnson, MD, Rosemary Lopez, and Karla Zadnik, OD, PhD].

Supported by National Institutes of Health/National Eye Institute (grant EY13153 [EMH]) and by funding from Research to Prevent Blindness (grant to the University of Arizona Department of Ophthalmology and Vision Science [JMM]), a Walt and Lilly Disney Award for Amblyopia Research (JMM), and a Career Development Award (EMH).

References

  • 1.Trager MJ, Dirani M, Fan Q, et al. Testability of vision and refraction in preschoolers: the strabismus, amblyopia, and refractive error study in singaporean children. Am J Ophthalmol. 2009;148:235–241. doi: 10.1016/j.ajo.2009.02.037. [DOI] [PubMed] [Google Scholar]
  • 2.Pai AS, Rose KA, Samarawickrama C, et al. Testability of refraction, stereopsis, and other ocular measures in preschool children: the Sydney Paediatric Eye Disease Study. J AAPOS. 2012;16:185–192. doi: 10.1016/j.jaapos.2011.09.017. [DOI] [PubMed] [Google Scholar]
  • 3.Harvey EM, Miller JM, Wagner LK, Dobson V. Reproducibility and accuracy of measurements with a hand held autorefractor in children. Br J Ophthalmol. 1997;81:941–948. doi: 10.1136/bjo.81.11.941. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Cordonnier M, Dramaix M. Screening for abnormal levels of hyperopia in children: a non-cycloplegic method with a hand held refractor. Br J Ophthalmol. 1998;82:1260–1264. doi: 10.1136/bjo.82.11.1260. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Cordonnier M, Dramaix M, Kallay O, de Bideran M. How accurate is the hand-held refractor Retinomax(R) in measuring cycloplegic refraction: a further evaluation. Strabismus. 1998;6:133–142. doi: 10.1076/stra.6.3.133.661. [DOI] [PubMed] [Google Scholar]
  • 6.el-Defrawy S, Clarke WN, Belec F, Pham B. Evaluation of a hand-held autorefractor in children younger than 6. J Pediatr Ophthalmol Strabismus. 1998;35:107–109. doi: 10.3928/0191-3913-19980301-10. [DOI] [PubMed] [Google Scholar]
  • 7.Dobson V, Miller JM, Harvey EM. Corneal and refractive astigmatism in a sample of 3- to 5-year-old children with a high prevalence of astigmatism. Optom Vis Sci. 1999;76:855–860. doi: 10.1097/00006324-199912000-00022. [DOI] [PubMed] [Google Scholar]
  • 8.Miller JM, Harvey EM, Dobson V. Visual acuity screening versus noncycloplegic autorefraction screening for astigmatism in Native American preschool children. J AAPOS. 1999;3:160–165. doi: 10.1016/s1091-8531(99)70062-5. [DOI] [PubMed] [Google Scholar]
  • 9.Harvey EM, Miller JM, Dobson V, Tyszko R, Davis AL. Measurement of refractive error in Native American preschoolers: validity and reproducibility of autorefraction. Optom Vis Sci. 2000;77:140–149. doi: 10.1097/00006324-200003000-00013. [DOI] [PubMed] [Google Scholar]
  • 10.Wesemann W, Dick B. Accuracy and accommodation capability of a handheld autorefractor. J Cataract Refract Surg. 2000;26:62–70. doi: 10.1016/s0886-3350(99)00325-9. [DOI] [PubMed] [Google Scholar]
  • 11.Cordonnier M, Kallay O. Non-cycloplegic screening for refractive errors in children with the hand-held autorefractor Retinomax: final results and comparison with non-cycloplegic photoscreening. Strabismus. 2001;9:59–70. doi: 10.1076/stra.9.2.59.701. [DOI] [PubMed] [Google Scholar]
  • 12.Miller JM, Dobson V, Harvey EM, Sherrill DL. Comparison of pre-school vision screening methods in a population with a high prevalence of astigmatism. Invest Ophthalmol Vis Sci. 2001;42:917–924. [PubMed] [Google Scholar]
  • 13.Gole GA, Schluter PJ, Hall J, Colville D. Comparison of the Retinomax autorefractor with hand-held retinoscopy in 1-year-old infants. Clin Experiment Ophthalmol. 2003;31:341–347. doi: 10.1046/j.1442-9071.2003.00668.x. [DOI] [PubMed] [Google Scholar]
  • 14.Liang CL, Hung KS, Park N, Chan P, Juo SH. Comparison of measurements of refractive errors between the hand-held Retinomax and on-table autorefractors in cyclopleged and noncyclopleged children. Am J Ophthalmol. 2003;136:1120–1128. doi: 10.1016/s0002-9394(03)00789-x. [DOI] [PubMed] [Google Scholar]
  • 15.Steele G, Ireland D, Block S. Cycloplegic autorefraction results in pre-school children using the Nikon Retinomax Plus and the Welch Allyn SureSight. Optom Vis Sci. 2003;80:573–577. doi: 10.1097/00006324-200308000-00010. [DOI] [PubMed] [Google Scholar]
  • 16.Cordonnier M, De Maertelaer V. Comparison between two hand-held autorefractors: the Sure-Sight and the Retinomax. Strabismus. 2004;12:261–274. doi: 10.1080/09273970490886594. [DOI] [PubMed] [Google Scholar]
  • 17.Schmidt P, Maguire M, Dobson V, et al. Vision in Preschoolers Study Group. Comparison of preschool vision screening tests as administered by licensed eye care professionals in the Vision in Preschoolers Study. Ophthalmology. 2004;111:637–650. doi: 10.1016/j.ophtha.2004.01.022. [DOI] [PubMed] [Google Scholar]
  • 18.Vision in Preschoolers Study Group. Preschool vision screening tests administered by nurse screeners compared with lay screeners in the vision in preschoolers study. Invest Ophthalmol Vis Sci. 2005;46:2639–2648. doi: 10.1167/iovs.05-0141. [DOI] [PubMed] [Google Scholar]
  • 19.Ying GS, Kulp MT, Maguire M, Ciner E, Cyert L, Schmidt P Vision in Preschoolers Study Group. Sensitivity of screening tests for detecting vision in preschoolers-targeted vision disorders when specificity is 94% Optom Vis Sci. 2005;82:432–438. doi: 10.1097/01.OPX.0000162660.14378.30. [DOI] [PubMed] [Google Scholar]
  • 20.Borchert M, Wang Y, Tarczy-Hornoch K, et al. MEPEDS Study Group. Testability of the Retinomax autorefractor and IOLMaster in preschool children: the Multi-ethnic Pediatric Eye Disease Study. Ophthalmology. 2008;115:1422–1425. doi: 10.1016/j.ophtha.2007.10.036. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Prabakaran S, Dirani M, Chia A, et al. Cycloplegic refraction in pre-school children: comparisons between the hand-held autorefractor, table-mounted autorefractor and retinoscopy. Ophthalmic Physiol Opt. 2009;29:422–426. doi: 10.1111/j.1475-1313.2008.00616.x. [DOI] [PubMed] [Google Scholar]
  • 22.Giordano L, Friedman DS, Repka MX, et al. Prevalence of refractive error among preschool children in an urban population: the Baltimore Pediatric Eye Disease Study. Ophthalmology. 2009;116:739–746. doi: 10.1016/j.ophtha.2008.12.030. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Kulp MT Vision in Preschoolers Study Group. Findings from the Vision in Preschoolers (VIP) Study. Optom Vis Sci. 2009;86:619–623. doi: 10.1097/OPX.0b013e3181a59bf5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Borchert M, Tarczy-Hornoch K, Cotter SA, Liu N, Azen SP, Varma R MEPEDS Group. Anisometropia in Hispanic and African American infants and young children the multi-ethnic pediatric eye disease study. Ophthalmology. 2010;117:148–153. doi: 10.1016/j.ophtha.2009.06.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Paff T, Oudesluys-Murphy AM, Wolterbeek R, et al. Screening for refractive errors in children: the plusoptiX S08 and the Retinomax K-plus2 performed by a lay screener compared to cycloplegic retinoscopy. J AAPOS. 2010;14:478–483. doi: 10.1016/j.jaapos.2010.09.015. [DOI] [PubMed] [Google Scholar]
  • 26.Ciner E, Carter A, Ying GS, Maguire M, Kulp MT Vision in Pre-schoolers (VIP) Study Group. Comparison of the Retinomax and Palm-AR Auto-Refractors: a pilot study. Optom Vis Sci. 2011;88:830–836. doi: 10.1097/OPX.0b013e3182192658. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Ying GS, Maguire M, Quinn G, Kulp MT, Cyert L Vision in Pre-schoolers (VIP) Study Group. ROC analysis of the accuracy of Non-cycloplegic retinoscopy, Retinomax Autorefractor, and SureSight Vision Screener for preschool vision screening. Invest Ophthalmol Vis Sci. 2011;52:9658–9664. doi: 10.1167/iovs.11-8559. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Adams RJ, Dalton SM, Murphy AM, Hall HL, Courage ML. Testing young infants with the Welch Allyn SureSight non-cycloplegic autorefractor. Ophthalmic Physiol Opt. 2002;22:546–551. doi: 10.1046/j.1475-1313.2002.00073.x. [DOI] [PubMed] [Google Scholar]
  • 29.Schimitzek T, Wesemann W. Clinical evaluation of refraction using a handheld wavefront autorefractor in young and adult patients. J Cataract Refract Surg. 2002;28:1655–1666. doi: 10.1016/s0886-3350(02)01426-8. [DOI] [PubMed] [Google Scholar]
  • 30.Schimitzek T, Schworm HD. Wave-front analysis as screening technique for amblyogenic ametropia with and without cycloplegia. Strabismus. 2003;11:133–143. doi: 10.1076/stra.11.3.133.16648. [DOI] [PubMed] [Google Scholar]
  • 31.Büchner TF, Schnorbus U, Grenzebach UH, Busse H. Examination of preschool children for ametropia: first experiences using a new hand-held autorefractor. Strabismus. 2004;12:111–117. doi: 10.1080/09273970490517854. [DOI] [PubMed] [Google Scholar]
  • 32.Iuorno JD, Grant WD, Noël LP. Clinical comparison of the Welch Allyn SureSight handheld autorefractor versus cycloplegic autorefraction and retinoscopic refraction. J AAPOS. 2004;8:123–127. doi: 10.1016/j.jaapos.2003.10.006. [DOI] [PubMed] [Google Scholar]
  • 33.Rowatt AJ, Donahue SP, Crosby C, Hudson AC, Simon S, Emmons K. Field evaluation of the Welch Allyn SureSight vision screener: incorporating the vision in preschoolers study recommendations. J AAPOS. 2007;11:243–248. doi: 10.1016/j.jaapos.2006.09.008. [DOI] [PubMed] [Google Scholar]
  • 34.Harvey EM, Dobson V, Miller JM, et al. Accuracy of the Welch Allyn SureSight for measurement of magnitude of astigmatism in 3- to 7-year-old children. J AAPOS. 2009;13:466–471. doi: 10.1016/j.jaapos.2009.08.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Silverstein E, Lorenz S, Emmons K, Donahue SP. Limits on improving the positive predictive value of the Welch Allyn SureSight for pre-school vision screening. J AAPOS. 2009;13:45–50. doi: 10.1016/j.jaapos.2008.08.011. [DOI] [PubMed] [Google Scholar]
  • 36.Dobson V, Harvey EM, Clifford-Donaldson CE, Green TK, Miller JM. Amblyopia in astigmatic infants and toddlers. Optom Vis Sci. 2010;87:330–336. doi: 10.1097/OPX.0b013e3181d951c8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Harvey EM, Dobson V, Clifford-Donaldson CE, Green TK, Messer DH, Miller JM. Prevalence of astigmatism in Native American infants and children. Optom Vis Sci. 2010;87:400–405. doi: 10.1097/OPX.0b013e3181d95b23. [DOI] [PubMed] [Google Scholar]
  • 38.Suryakumar R, Bobier WR. The manifestation of noncycloplegic refractive state in pre-school children is dependent on autorefractor design. Optom Vis Sci. 2003;80:578–586. doi: 10.1097/00006324-200308000-00012. [DOI] [PubMed] [Google Scholar]
  • 39.Choong YF, Chen AH, Goh PP. A comparison of autorefraction and subjective refraction with and without cycloplegia in primary school children. Am J Ophthalmol. 2006;142:68–74. doi: 10.1016/j.ajo.2006.01.084. [DOI] [PubMed] [Google Scholar]
  • 40.Kershner RM, Brick DC. Prevalence of high corneal astigmatism in Papago school children. Invest Ophthalmol Vis Sci. 1984;25(Suppl):217. [Google Scholar]
  • 41.Dobson V, Miller JM, Harvey EM, Sherrill DL. Vision Science and Its Applications. Washington, DC: Optical Society of America; 1999. Prevalence of astigmatism, astigmatic anisometropia, and glasses wearing among pre-school- and school-age Native American children; pp. 177–180. [Google Scholar]
  • 42.Harvey EM, Dobson V, Miller JM. Prevalence of high astigmatism, eyeglass wear, and poor visual acuity among Native American grade school children. Optom Vis Sci. 2006;83:206–212. doi: 10.1097/01.opx.0000214333.84822.71. [DOI] [PubMed] [Google Scholar]
  • 43.Harvey EM, Dobson V, Miller JM, et al. Prevalence of corneal astigmatism in Tohono O’odham Native American children 6 months to 8 years of age. Invest Ophthalmol Vis Sci. 2011;52:4350–4355. doi: 10.1167/iovs.10-6061. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Harvey EM, Miller JM, Schwiegerling J, Sherrill D, Messer DH, Dobson V. Developmental changes in anterior corneal astigmatism in Tohono O’odham Native American infants and children. Ophthalmic Epidemiol. 2013;20:102–108. doi: 10.3109/09286586.2013.767355. [DOI] [PubMed] [Google Scholar]
  • 45.Straub J, Schwiegerling J, Gupta A. Vision Science and Its Applications, OSA Technical Digest. Washington DC: Optical Society of America; 2011. Design of a compact Shack–Hartmann aberrometer for real-time measurement of aberrations in human eyes; pp. 110–113. [Google Scholar]
  • 46.Long WF. A matrix formalism for decentration problems. Am J Optom Physiol Opt. 1976;53:27–33. doi: 10.1097/00006324-197601000-00005. [DOI] [PubMed] [Google Scholar]
  • 47.Harris WF. The mean and variance of samples of dioptric power: the basic calculations. Clin Exp Optom. 1990;73:89–92. [Google Scholar]
  • 48.Miller JM. Clinical applications of power vectors. Optom Vis Sci. 2009;86:599–602. doi: 10.1097/OPX.0b013e3181a6a211. [DOI] [PubMed] [Google Scholar]
  • 49.Millodot M, Thibault C. Variation of astigmatism with accommodation and its relationship with dark focus. Ophthalmic Physiol Opt. 1985;5:297–301. [PubMed] [Google Scholar]
  • 50.Ukai K, Ichihashi Y. Changes in ocular astigmatism over the whole range of accommodation. Optom Vis Sci. 1991;68:813–818. doi: 10.1097/00006324-199110000-00011. [DOI] [PubMed] [Google Scholar]
  • 51.Mutti DO, Enlow NL, Mitchell GL. Accommodation and induced with-the-rule astigmatismin emmetropes. Optom Vis Sci. 2001;78:6–7. doi: 10.1097/00006324-200101010-00004. [DOI] [PubMed] [Google Scholar]
  • 52.Cheng H, Barnett JK, Vilupuru AS, et al. A population study on changes in wave aberrations with accommodation. J Vis. 2004;4:272–280. doi: 10.1167/4.4.3. [DOI] [PubMed] [Google Scholar]
  • 53.Radhakrishnan H, Charman WN. Changes in astigmatism with accommodation. Ophthalmic Physiol Opt. 2007;27:275–280. doi: 10.1111/j.1475-1313.2007.00474.x. [DOI] [PubMed] [Google Scholar]
  • 54.Tsukamoto M, Nakajima K, Nishino J, Hara O, Uozato H, Saishin M. Accommodation causes with-the-rule astigmatism in emmetropes. Optom Vis Sci. 2000;77:150–155. doi: 10.1097/00006324-200003000-00014. [DOI] [PubMed] [Google Scholar]
  • 55.Donahue SP, Arthur B, Neely DE, Arnold RW, Silbert D, Ruben JB. AAPOS Vision Screening Committee. Guidelines for automated pre-school vision screening: a 10-year, evidence-based update. J AAPOS. 2013;17:4–8. doi: 10.1016/j.jaapos.2012.09.012. [DOI] [PubMed] [Google Scholar]
  • 56.Horwood AM, Riddell PM. Receding and disparity cues aid relaxation of accommodation. Optom Vis Sci. 2009;86:1276–1286. doi: 10.1097/OPX.0b013e3181bb41de. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

1
2

RESOURCES