Skip to main content
PLOS One logoLink to PLOS One
. 2014 Apr 2;9(4):e92792. doi: 10.1371/journal.pone.0092792

Quantitative Study of the Effect of Tissue Microstructure on Contraction in a Computational Model of Rat Left Ventricle

Valentina Carapella 1,*, Rafel Bordas 1, Pras Pathmanathan 1, Maelene Lohezic 2, Jurgen E Schneider 2, Peter Kohl 3, Kevin Burrage 1, Vicente Grau 4
Editor: Vincenzo Lionetti5
PMCID: PMC3973660  PMID: 24695115

Abstract

Tissue microstructure, in particular the alignment of myocytes (fibre direction) and their lateral organisation into sheets, is fundamental to cardiac function. We studied the effect of microstructure on contraction in a computational model of rat left ventricular electromechanics. Different fibre models, globally rule-based or locally optimised to DT-MRI data, were compared, in order to understand whether a subject-specific fibre model would enhance the predictive power of our model with respect to the global ones. We also studied the impact of sheets on ventricular deformation by comparing: (a) a transversely isotropic versus an orthotropic material law and (b) a linear model with a bimodal model of sheet transmural variation. We estimated ejection fraction, wall thickening and base-to-apex shortening and compared them with measures from cine-MRI. We also evaluated Lagrangian strains as local metrics of cardiac deformation. Our results show that the subject-specific fibre model provides little improvement in the metric predictions with respect to global fibre models while material orthotropy allows closer agreement with measures than transverse isotropy. Nonetheless, the impact of sheets in our model is smaller than that of fibres. We conclude that further investigation of the modelling of sheet dynamics is necessary to fully understand the impact of tissue structure on cardiac deformation.

Introduction

Cardiac tissue is arranged into a complex architecture. Due to their elongated shape, myocytes are highly anisotropic and their local orientation in cardiac tissue is usually called the fibre direction [1]. Furthermore, the extracellular connective tissue matrix that surrounds myocytes groups them into layers 4-6 cells thick [2], separated by cleavage planes, forming a branching laminar architecture. Such layers are commonly referred to as sheets. Although there is general agreement about the local alignment of cells and their organisation into sheets, disagreement remains on their exact characteristics in beating hearts, their alteration due to pathology and in general their degree of contribution to cardiac function [3]. Tissue microstructure contributes to the heterogeneity of tissue conductivity and therefore directly affects electrical wave propagation, with dramatic consequences in the case of pathology. Regarding mechanics, the importance of taking into account fibre and sheet orientation in the definition of passive and active behaviour of cardiac tissue has already been highlighted [4]. It is along the fibre direction that electrical excitation propagates fastest and that the principal component of contraction takes place. When included in an electromechanical model, fibres are often mathematically prescribed [5]. Recent advances in imaging technology have made it possible to measure local microstructure from data such as ex vivo diffusion tensor MRI (DT-MRI). The primary eigenvector of the diffusion tensor has been shown to correlate with the fibre direction in the tissue [6]. Electromechanical models based on DT-MRI data suggest that fibres are a dynamical system in cardiac structure, undergoing adaptation that minimises shear strains, behaviour that can have important consequences in tissue remodelling in pathology [7]. The importance of local myocyte orientation in cardiac function, both in health and disease, has promoted considerable effort in recent years towards subject-specific modelling of cardiac electromechanics [8], [9], [10]. Pathological conditions such as dyssynchrony [11] have been investigated, with realistic ventricular to whole-organ geometries, combined with fibre orientations obtained from imaging [10]. The results are promising, but it is an open question as to whether current electromechanical models are becoming a useful support tool in clinical decision-making.

The laminar structure of myocardial tissue is also important for cardiac electromechanics. It has been established that sheets undergo shortening in the fibre direction, extension in the in-sheet/cross-fibre plane, thickening and shear, whose regional variability and transmural distribution are important for the distribution of strain and stress throughout the ventricle during cardiac motion [12]. More recently, changes in sheet intersection angles have been identified to occur during the cycle of contraction and relaxation [13]. These sheet dynamics are thought to form one of the underlying mechanisms to explain wall-thickening during contraction [14]. Sheets have been modelled as continuously varying transmurally [2], although more recent experimental findings suggest that the transmural distribution of sheets is more complex and discontinuous [13], see for example Figure 1(f). Sheet orientations directly obtained from histological data, usually from a small number of ventricular locations only, have been employed in computational studies of the effect of tissue microstructure on electrophysiology [15], but in general the importance of sheets has not been fully acknowledged in the cardiac modelling community in spite of the experimental evidence.

Figure 1. Modelling ventricular geometry and tissue structure.

Figure 1

(a) The ellipsoidal mesh seen in a transmural-longitudinal cut. (b) Basal slice of the mesh cut parallel to the short axis. (c) Midventricular slice from rat cine-MRI at beginning of contraction. (d)-(e) Helix, and sheet angle definition. (f) Image of transmural histological sample highlighting the sheets.

Two motivations underlie our study. First, we aim to understand whether the use of subject-specific fibres would enhance the predictive power of our model, or whether it would be as informative as simple globally prescribed fibres within our modelling framework. To this purpose, globally defined rule-based fibres were compared with a subject-specific model of fibres that is locally optimised in order to minimise the discrepancy with DT-MRI data [5].

Our second motivation is the exploration of the often underestimated importance of sheet dynamics in the common electromechanical models. We want to test the impact of sheet orientation in the mechanics of the left ventricle. This was achieved by (a) comparing transverse isotropic with orthotropic material laws for cardiac tissue and (b) under the orthotropic material properties, testing two global models of transmural variation of the sheet orientation, namely a linear and a bimodal model. The aim of the latter comparison was to see whether the latest findings regarding the discontinuous multiple-population distribution of sheets [13] (mimicked by the bimodal model) can improve the accuracy of the electromechanical model, as opposed to the standard smooth variation of sheet orientation [2] (the linear model).

In order to quantify the effect of the different models of fibre and sheet orientation on contraction, global and local metrics were considered. The global metrics are ejection fraction, wall thickening, and shortening in the base-to-apex direction. We compared their predicted values with those obtained from rat cine-MRI data. The local metrics considered are the Lagrangian circumferential strain, as a measure of contraction, circumferential-radial shear strain, as a measure of the relative twist of sub-endocardial and sub-epicardial layers, and circumferential-longitudinal shear strain, as a measure of torsion [16].

A preliminary study of the effect of fibre direction and material orthotropy on contraction had been performed with a simplified electromechanical model (without pressure boundary conditions) [17]. The current study represents a significant extension in our model development, to further the study of the impact of sheets and the analysis of the local effect of tissue structure on deformation. The contribution of the study is twofold. First, we show that the fibre model affects significantly the prediction of the metrics considered. Therefore, it is important to choose the most suitable fibre setting. On the other hand, our results question the efficacy of using personalised myocyte orientations when compared to the limitations of state-of-the-art electromechanical models, since they do not seem to provide substantial improvements, both in terms of global and local measures, compared to simpler global rule-based fibre definitions, at least for the healthy left ventricle of rat. Secondly, we highlight the need for further development of models of sheets. On the one hand, the introduction of sheet orientation in the model by switching from transverse isotropy to orthotropy shows a small but consistent improvement in the metrics predictions. On the other hand, we found that, although experimentally more realistic, the bimodal model for sheet orientation did not improve and in some cases counteracted the effect of introducing material orthotropy. We believe that such an important structural change should affect more evidently the predicted deformation patterns. Given the results presented in this study, we conclude that our current electromechanical modelling approach may not be able to successfully make use of subject-specific tissue structure, with all its additional complexity and computational cost, unless a better understanding of the biological roles, and the computational modelling of sheets and their mechanical properties is achieved.

Materials and Methods

No new animal experiment was required for the results presented in this paper. The images used come from a dataset previously published and for which the ethics statement was duly reported [18]. However, with respect to those experiments, the authors confirm that all animal work was conducted in accordance with Schedule 1 of the UK Home Office Guidance on the Operation of Animals (Scientific Procedures) Act of 1986, and was approved by the Oxford University ethical review board.

MRI dataset

In vivo cine-MRI and subsequent ex vivo DT-MRI of rat hearts were acquired on a 9.4T (400 MHz) MR system (Agilent, Santa Clara, CA, USA). The cine-MRI dataset used a 2D multi-frame gradient echo sequence, and consisted of a stack of eight contiguous short-axis slices covering the heart from apex to the atrioventricular separation. Each short-axis slice comprised of 32–36 frames acquired throughout the cardiac cycle with an in-plane resolution of Inline graphic and a slice thickness of Inline graphic. A short-axis view in end-diastole is shown in Figure 1(c). The DT-MRI images where subsequently acquired on excised rat hearts, fixed either in resting state or in contracture and embedded in agarose, at an isotropic resolution of Inline graphic as described in [18].

Geometrical mesh for rat left ventricle

We approximate the left ventricle with a thick-walled truncated ellipsoid. A first coarse tetrahedral mesh was generated with semi-axes and wall thickness estimated from the end-diastolic frame of one of the cine-MRI rat scans described (Figure 1(c)), which we took as the reference mesh (Figures 1(a) –1(b)). In order to estimate the shape of a mesh representative of the left ventricle in absence of blood pressure (called pre-P mesh), an iterative approach was applied. The reference mesh was shrunk by applying a uniform scaling matrix to give the pre-P mesh, which was then allowed to expand passively under a constant pressure of Inline graphic applied to the endocardial surface to give the post-P mesh (the negative sign means that the pressure is applied inwards along the normal to the surface). This step was repeated for several iterations adjusting the scaling factor until we obtained an optimal pre-P mesh producing a post-P mechanics mesh close to the reference mesh. Details about the pre-P and post-P meshes are given in Table 1. The mechanics mesh for the electromechanical simulations is the pre-P mesh resulting from the optimisation performed, and has quadratic elements. The mesh for the electrophysiological component is instead obtained by refining the post-P mechanics mesh and has approximately Inline graphic linear tetrahedral elements with a mean edge length of Inline graphic. All meshes were generated with the open-source 3D finite element grid generator Gmsh [19].

Table 1. Mechanical mesh properties.

pre-P mesh post-P mesh
Inline graphic 0.34 0.40
Inline graphic 0.48 0.48
Inline graphic 0.95 0.99
Inline graphic 0.16 0.26
Inline graphic 0.27 0.3
Inline graphic 0.79 0.84
mean wall thickness 0.18 0.16
Cavity volume (Inline graphic) 0.07 0.132
Tissue volume (Inline graphic) 0.267 0.267
Mean edge length Inline graphic Inline graphic
No. of elements Inline graphic Inline graphic

Mechanical mesh properties before (pre-P) and after (post-P) passive expansion under pressure. Length unit is Inline graphic. See Figures 1(a) –1(b) for reference to the ellipsoid parameters.

Tissue structure definition

Tissue structure is defined at the centroid of each element of the mechanical mesh by assigning fibre, sheet and sheet-normal directions. This orthonormal local system of coordinates is assigned according to a well-established approach [2]. First, the orthonormal system of material coordinates (radial Inline graphic, circumferential Inline graphic and longitudinal Inline graphic directions) for the centroid of a given element is identified. A first rotation about the radial direction Inline graphic is performed, that transforms the vectors Inline graphic and Inline graphic into Inline graphic and Inline graphic. The rotation angle Inline graphic is the helix angle that defines the fibre direction Inline graphic. The second step consists of a rotation about the fibre direction Inline graphic of the angle Inline graphic, the sheet angle. The vector Inline graphic is rotated to Inline graphic that represents the sheet direction Inline graphic, while the vector Inline graphic is rotated into Inline graphic that gives the sheet-normal direction Inline graphic. Figures 1(d) and 1(e) illustrate the first and second step, respectively.

Different models for the fibre and sheet orientation are introduced in this tissue structure generation framework by modelling the transmural variation of the helix and sheet angle as described below.

Models of fibre direction

A set of rule-based globally defined fibres were generated by assigning to each element of the mesh a value of the helix angle Inline graphic, defined as the function Inline graphic and calculated by eqn. (1)

graphic file with name pone.0092792.e040.jpg (1)

where Inline graphic stands for the sign function, Inline graphic is the normalised transmural depth, varying from Inline graphic to Inline graphic from endocardium to epicardium, Inline graphic is the transmural rotation, i.e. the maximum absolute value of Inline graphic allowed by the model, which will span between Inline graphic at epicardium and Inline graphic and endocardium. Finally, the exponent Inline graphic modulates the transmural variation of Inline graphic, so for Inline graphic it will be linear, Inline graphic cubic. This is a standard approach for globally prescribed fibres introduced by Streeter et al. [1]. Four values of Inline graphic were tested, Inline graphic degrees, spanning the range of values found experimentally [5]. For each value of Inline graphic, four values of the exponent Inline graphic were considered, Inline graphic, for a total of 16 globally defined fibre models. In the rest of the paper, these models are referred to as SnInline graphicRInline graphic, where S stands for Streeter-based and nInline graphicRInline graphic refers to the value of Inline graphic and Inline graphic used. For example, the fibre model Sn0.5R70 is obtained by imposing Inline graphic and Inline graphic in eqn. (1). Figure 2(a) shows the transmural variation of Inline graphic for a subset of these fibre models.

Figure 2. Helix and sheet angle variation.

Figure 2

(a) Transmural models of the helix angle Inline graphic for four of the global rule-based fibre models. (b) Transmural models of sheet angle Inline graphic.

The global fibre models are compared with a subject-specific fibre model developed by Karadag et al. [5]. This is based on a local optimisation of Inline graphic and Inline graphic carried out on 6 subjects from the DT-MRI rat dataset previously described. The cine-MRI rat scan used to generate the mesh comes from one of the subjects from this set. The left ventricle was divided into 16 regions, an adaptation of the 17-region classification of the American Heart Association [20], and on each of them eqn. (1) was fitted in order to minimise the angular difference with the data. The result is a 16-regions model of fibres angles, with a single couple Inline graphic obtained for each region. We refer to this model as Karadag.

Models of sheet orientation

The standard approach to the modelling of sheet orientation is that of a smooth variation in the transmural direction [2]. Recent experiments question this modelling approach showing the presence in the tissue of sheet populations with opposing orientation angles [3] and a strong level of discontinuity [13]. In order to compare the effect of the two different approaches, we have compared a simple linear transmural variation of the sheet angle Inline graphic with a bimodal model. The linear model for Inline graphic goes from Inline graphic at endocardium to Inline graphic at epicardium, and is described by Inline graphic. The bimodal model consists of a continuous approximation obtained by means of the sigmoidal function in eqn. (2)

graphic file with name pone.0092792.e077.jpg (2)

where Inline graphic is a parameter affecting the steepness of the sigmoidal function. We chose Inline graphic in order to have a distinct but smooth step in the trace. Figure 2(b) shows the transmural variation of the sheet angle Inline graphic for the two models used in this study. In the following, unless it is specified, the linear model for the sheet angle is used.

Electromechanical model

Model of electrophysiology

At the tissue level the monodomain equations (eqn. (3) and (4)) for electrical wave propagation are solved,

graphic file with name pone.0092792.e081.jpg (3)
graphic file with name pone.0092792.e082.jpg (4)

where Inline graphic is the transmembrane voltage (Inline graphic), Inline graphic is time (Inline graphic), Inline graphic is the membrane capacitance (Inline graphic), Inline graphic is the surface area-to-volume ratio (Inline graphic), Inline graphic is the effective conductivity (Inline graphic), a matrix encoding the conductivity along the fibre, sheet and sheet-normal directions. The function Inline graphic is the ionic current provided by the cell model (Inline graphic) and Inline graphic is the external stimulus (Inline graphic). The vector Inline graphic represents the set of state variables forming the cell electrophysiological model, whose temporal variation is regulated by the ordinary differential equation (ODE) system in eqn. (4). The model of cellular electrophysiology is that of Wang and Sobie [21]. Table 2 provides the parameters values we used for eqn. (3). The value of the surface area-to-volume ratio Inline graphic is typical for rat myocytes [22]. The conductivities were adjusted in order to ensure that the resulting conduction velocity in the fibre and cross-fibre directions was within experimental range, with ratio Inline graphic [23]. Cubic wedge simulations of electrophysiology with straight fibres parallel to one of the coordinates axes were used for this purpose.

Table 2. Parameters of the monodomain equation (eq. (3)).
Parameter Value(s)
Inline graphic Inline graphic
Inline graphic Inline graphic
Inline graphic Inline graphic
stim duration Inline graphic
Inline graphic Inline graphic
Inline graphic Inline graphic
Inline graphic Inline graphic

Model of mechanical behaviour

The mechanical component is coupled to the electrical component via the transmembrane voltage. At the tissue level, the mechanical behaviour is modelled according to finite elasticity theory. Let us consider two systems of Cartesian coordinates, a reference system defined on the undeformed body, Inline graphic, and a second system representing the deformed state, Inline graphic. The components of the deformation gradient tensor Inline graphic, which describes the transformation from the undeformed state to deformed one, can be written as Inline graphic. The Green deformation tensor Inline graphic, i.e. Inline graphic, describes the deformation in the undeformed coordinate system. Finally, the Lagrangian strain tensor is Inline graphic, where Inline graphic is the identity matrix.

The Inline graphic Piola-Kirchoff stress tensor Inline graphic for the total stress produced by the tissue is the sum Inline graphic of the stress due to the tissue passive response, Inline graphic, and active contraction, Inline graphic. The constitutive relation between passive stress and strain is given by Inline graphic, where Inline graphic is the exponential strain-energy function used by Usyk et al. [4] and given in eqn. (5),

graphic file with name pone.0092792.e128.jpg (5)
graphic file with name pone.0092792.e129.jpg

where Inline graphic, Inline graphic is a stiffness constant and Inline graphic for Inline graphic are stiffness parameters. The parameter Inline graphic regulates the level of compressibility allowed by the material law: the higher the value the closer it is to being incompressible. After a preliminary analysis of the effect Inline graphic on the overall compressibility of the tissue we chose Inline graphic, since it ensures a negligible volume reduction Inline graphic between beginning and end of contraction. Furthermore the distribution of the Jacobian of the deformation Inline graphic over the mesh elements between beginning and end of contraction has an average Inline graphicInline graphic percentile range of Inline graphicInline graphic, confirming that the model is nearly incompressible.

Two models of material passive behaviour were tested representing transversely isotropic and orthotropic behaviour. The stiffness parameters for the orthotropic case are taken from [4]. The parameters for the transversely isotropic law are obtained by averaging the relevant parameters of the orthotropic law. The parameter values for both laws are reported in Table 3.

Table 3. Stiffness parameters values for the material law (eq. (5)).
Parameter transverse isotropy orthotropy
Inline graphic 6.0 6.0
Inline graphic 4.3 7.0
Inline graphic 4.3 3.0
Inline graphic 7.5 12.0
Inline graphic 7.5 3.0
Inline graphic 4.3 3.0

The active stress at the tissue level, Inline graphic, depends on the active tension generated at the cell level. The cell contraction model we used was originally developed by Kerkchoffs [24] for canine myocytes. The model parameters associated with the mechanical activation time in the twitch component of the model, (Inline graphic and Inline graphic), were reduced by Inline graphic in order to get a shorter contraction duration (Inline graphic), more compatible with the rat cardiac cycle frequency, while still generating an analogous amount of active tension (Inline graphic at peak contraction) in that shorter interval. Finally, the total stress Inline graphic is required to satisfy the conservation of momentum as shown in eq. (6)

graphic file with name pone.0092792.e156.jpg (6)

where the effect of inertia and gravity is neglected. The system is solved with appropriate Dirichlet boundary conditions for displacement and Neumann boundary conditions for tractions, in this case the blood cavity pressure onto the endocardial surface, which is defined as follows.

Cavity pressure trace

The temporal evolution of the intra-cavital blood pressure is approximated by means of a sigmoidal function ranging from Inline graphic to Inline graphic, where the negative sign is due to the fact the pressure is applied in the inward direction along the normal to the surface. The range of pressure applied is significantly lower than that typically measured in the rat left ventricle, which reaches approximately Inline graphic (or more, for example during physical activity) at end-systole [25]. This is a known limitation of some contraction models and follows existing computational modelling literature [26]. However, the chosen pressure trace ensures that the left ventricle undergoes first an isovolumic contraction and then an ejection phase. Figure 3(a) shows the pressure trace with an example of the resulting cavity volume.

Figure 3. Pressure and volume traces and global metric Inline graphic.

Figure 3

(a) Pressure trace and resulting cavity volume trace for simulation with fibre Sn1R70 and transverse isotropy. (b) Inline graphic for the different fibre models, with transversely isotropic material law.

Electromechanical simulations

All simulations were run using Chaste, an open-source simulation package for computational biology developed in our group (http://www.cs.ox.ac.uk/chaste) [27]. The simulation duration is Inline graphic which is approximately the time at which full contraction is achieved. The timesteps used for solving the electrophysiology are Inline graphic for the cell model (eq. (4)) and Inline graphic for the monodomain equation, while for the mechanics they are Inline graphic for the contraction model and Inline graphic for eq. (6). The numerical scheme used has been described in previous work [28]. A single electrical stimulus of Inline graphic intensity is applied to the apical region, identified as the lower Inline graphic of the left ventricle. This type of activation region is commonly used in experiments with Langendorff-perfused hearts, and it was chosen to mimic the apex-to-base direction of the electrical activation in the left ventricle. Dirichlet boundary conditions fix the nodes at the base of the ventricle in the long-axis direction, so that they are allowed to move in the short-axis plane.

Global and local metrics

The global measures used to evaluate the simulations are: ejection fraction Inline graphic, wall thickening Inline graphic and shortening in the base-to-apex direction Inline graphic. All the quantities are computed by comparing the state of the mesh at the beginning (Inline graphic) and end (Inline graphic) of contraction. Inline graphic is calculated as the relative difference between the mesh cavity volume Inline graphic at Inline graphic and Inline graphic, Inline graphic. Inline graphic is the difference in wall-thickness Inline graphic, Inline graphic, where Inline graphic at a given time is obtained by averaging four measures of wall-thickness taken symmetrically onto a short-axis slice in the midventricular region (at approximately Inline graphic of the long axis from the base). We chose this specific short-axis slice to compare with the cine images, where Inline graphic is more easily measured in the midventricular region. Inline graphic is calculated by comparing the Inline graphic coordinate of the epicardial apical node along the Inline graphic axis (which coincides with the long axis of the left ventricle, see Figure 1(a)) at Inline graphic and Inline graphic, Inline graphic. This is an adequate measure of the shortening along the base-to-apex direction since the base is kept fixed in the model and the apex moves almost exclusively along the long axis (of course, in situ, the movement is in the opposite direction, i.e. the atrio-ventricular valve plane moves ‘downwards’ in the direction of the apex, but in terms of changes in apico-basal length, this parameter offers a satisfactory approximation within the modelling framework used). Here Inline graphic represents shortening, while Inline graphic represents elongation of the ventricle during contraction.

In order to compare the predicted values with experimental data, we measured these metrics on the cine-MRI dataset used for building the ellipsoidal mesh by applying analogous methods. The measured values are Inline graphic, Inline graphic which are consistent with values in the literature [29], and Inline graphic.

As local metrics we considered the Lagrangian circumferential strain Inline graphic, and two shear strains, the circumferential-longitudinal shear strain Inline graphic, and the circumferential-radial shear strain Inline graphic. The Lagrangian strain tensor Inline graphic in the Cartesian system is obtained from the deformation tensor Inline graphic calculated during the simulation, that was sampled every Inline graphic. Then the conversion to cylindrical coordinates was applied. We could not compare these strain predictions directly with data, but they show good agreement with results in the literature as further explained in the Discussion.

Results

In this section we present the results of the series of electromechanical simulations we performed in order to (a) compare sixteen globally defined fibre models (SnInline graphicRInline graphic for Inline graphic and Inline graphic) against one subject-specific fibre model (Karadag), and (b) evaluate the effect of introducing sheets by comparing transverse isotropy to orthotropy and with linear and bimodal sheet models. The results are grouped into global and local measures.

Global measures

The global measures considered in this study are 1) ejection fraction Inline graphic, 2) wall thickening Inline graphic, and 3) shortening in the long-axis direction Inline graphic. The variation in Inline graphic due to the different fibre models is shown in Figure 3(b), with the transversely isotropic material law. Inline graphic is plotted vs Inline graphic, and the global fibre models SnInline graphicRInline graphic are grouped according to the exponent Inline graphic in order to highlight the pattern of Inline graphic with increasing values of Inline graphic for each value of the exponent Inline graphic. The single value of Inline graphic for the Karadag fibres is represented as an horizontal line. The predicted Inline graphic is overall in the range Inline graphicInline graphic, which can be considered physiological [30], but which is still lower than the measured value Inline graphic. Among the global fibre models, for Inline graphic increasing values of the angle Inline graphic and decreasing values of the exponent Inline graphic raise the value of Inline graphic. The reverse holds for Inline graphic, for which the increase in the maximum angle Inline graphic causes a rapid decrease of the Inline graphic. A possible explanation for this downward trend is provided in the Discussion. The subject-specific Karadag model gives one of the highest values of Inline graphic together with the global models SnInline graphicRInline graphic and SnInline graphicRInline graphic.

Changing from the transversely isotropic to the orthotropic material law (with the linear sheet model) has the general effect of increasing the Inline graphic value for all the fibre models, with an average increase of Inline graphic (percentage points), resulting in Inline graphic values in the range Inline graphicInline graphic, i.e. still below the measured value. Figure 4(a) shows the comparison of Inline graphic between transversely isotropic and orthotropic material laws with a linear sheet model for the simulations with global fibres with Inline graphic and Karadag fibres. Similar results are obtained for the other values of Inline graphic. Within the orthotropic case, the effect of using a linear or a bimodal sheet model has the interesting effect of producing predictions much closer to those obtained under transverse isotropy than to orthotropy with the linear sheet model, but in general with a less consistent pattern across the fibre models (and therefore this is not shown).

Figure 4. Material orthotropy vs transverse isotropy.

Figure 4

Effect of introducing sheets by swicthing from transverse isotropy to orthotropy. (a) Inline graphic (b) Inline graphic and (c) Inline graphic for global fibre models (with Inline graphic) and Karadag model.

For Inline graphic, Figure 5(a) represents the wall thickening Inline graphic vs Inline graphic, with the transversely isotropic material law. For the global fibre models, we observe the same trend as with Inline graphic, i.e. for increasing values of Inline graphic and decreasing values of Inline graphic Inline graphic increases. Karadag fibres still produce one of the highest values of Inline graphic, but some global fibres models also give good results. The use of the orthotropic material law with the linear sheet model further increases the value of Inline graphic for every fibre model, as shown in Figure 4(b), with an average increase of Inline graphic. The effect of varying the sheet model from linear to bimodal produces again values closer to the transversely isotropic case. Overall the range of variability for Inline graphic is Inline graphicInline graphic, with only some fibre models giving values close to the physiological range. In any case there is a clear discrepancy between the predicted Inline graphic values and that measured on cine-MRI, Inline graphic.

Figure 5. Global metrics Inline graphic and Inline graphic.

Figure 5

(a) Inline graphic and (b) Inline graphic for the different fibre models, with transversely isotropic material law.

The shortening in the base-to-apex direction (negative values of Inline graphic) is also substantially affected by the fibre type and material law, ranging from Inline graphic to Inline graphic. Figure 5(b) shows Inline graphic vs Inline graphic, with the transversely isotropic material law. Within the global fibre models SnInline graphicRInline graphic, high values of the exponent Inline graphic combined with low values of Inline graphic produce lengthening (positive values of Inline graphic), whereas there is increasing shortening for low values of Inline graphic and increasing values of Inline graphic. In particular, some global fibre models match or exceed the measured shortening Inline graphic. Karadag fibres produce a shortening value smaller than the measured one. The effect of changing form transversely isotropic to orthotropic material law (with the linear sheet model) is shown in Figure 4(c). The orthotropic material law increases the shortening by Inline graphic on average. By changing the sheet model to bimodal approximately Inline graphic less shortening was obtained.

Local measures

We considered the circumferential strain Inline graphic, the circumferential-longitudinal shear strain Inline graphic and the circumferential-radial shear strain Inline graphic, which were uniformly averaged in the basal (upper Inline graphic of the left ventricle), midmyocardial (middle Inline graphic of the left ventricle) and apical sections. We show only the average strain in the midmyocardial region, because it is a good measure of the average behaviour of the left ventricle. In the absence of direct strain data, we compared the predicted traces with experimental results in the literature. Figure 6(a) shows the Inline graphic trace for the subset of global fibres models with Inline graphic and for the Karadag model in the case of transverse isotropy. The Karadag model has an intermediate behaviour between the fibre models Sn1R70 and Sn1R80, as we have already found for the global measures. Amongst the global fibre models, the magnitude of the strain decreases for increasing values of the angle Inline graphic. All traces start from a positive value of Inline graphic rather than zero, due to the passive expansion performed prior to the electromechanical simulation, which leaves a residual strain component in Inline graphic. In order to compare predicted Inline graphic traces with experimental results on Inline graphic in rat, the study by Daire et al. [29], who employed cine-MRI and Tagged-MRI, was considered. The measurements of Inline graphic were taken by Daire et al. [29] at fixed percentages of the cardiac cycle, therefore it was necessary to convert this temporal subdivision into a sequence of time points in the range Inline graphicInline graphic (the duration of our simulations). The data (mean and standard deviation) for the first half of the cardiac cycle, which corresponds approximately to the simulation duration, are shown in red in Figure 6(b). The green line is the Inline graphic trace for the simulation with the Karadag fibre model and transverse isotropy, after subtraction of the residual strain from the pre-simulation passive expansion. Apart from the inevitable inaccuracy of the conversion from cardiac cycle percentages to the simulation time interval, there is very good agreement between predicted and measured Inline graphic.

Figure 6. Predicted temporal variation of Inline graphic.

Figure 6

(a) Average midventricular Inline graphic for global fibre models (with Inline graphic) and the Karadag model (b) Comparison of predicted Inline graphic for the simulation with the Karadag fibre model and transverse isotropy and measured Inline graphic in rat [29].

Figures 7(a) and 8(a) show the Inline graphic and Inline graphic midventricular traces for the subset of global fibres models with Inline graphic and for the Karadag model in the case of transverse isotropy. With regards to Inline graphic, the Karadag model shows an intermediate behaviour with respect to the other fibre models, for which the magnitude of the strain decreases for increasing values of the angle Inline graphic. To the best of our knowledge, data on temporal variation of such strains in rat heart was not available in the literature. Instead, we compared predicted shear strains with the measures performed in mouse by Zhong et al. [31]. As with the Inline graphic, it was necessary to convert from percentages of cardiac cycle to time points in the range Inline graphicInline graphic. Figures 7(b) and 8(b) show the comparison between data and predicted Inline graphic and Inline graphic, respectively, for the simulation with the Karadag fibre model and transverse isotropy. The agreement for Inline graphic is poorer than for Inline graphic. However, in both cases the trends are similar to the experimental ones.

Figure 7. Predicted temporal variation of Inline graphic.

Figure 7

(a) Average Inline graphic for global fibre models (with Inline graphic) and the Karadag model.(b) Comparison of predicted Inline graphic for the simulation with the Karadag fibre model and transverse isotropy and measured Inline graphic in mouse [31].

Figure 8. Predicted temporal variation of Inline graphic.

Figure 8

(a) Average midventricular Inline graphic for global fibre models (with Inline graphic) and the Karadag model. (b) Comparison of predicted Inline graphic for the simulation with the Karadag fibre model and transverse isotropy and measured Inline graphic in mouse[31].

The effect of sheets was negligible on Inline graphic, while it was substantial on the shear strains. Changing from transverse isotropy to orthotropy, and within the orthotropic behaviour, from a linear to a bimodal model for the sheets, caused a consistent increase in the magnitude of Inline graphic and Inline graphic, as shown in Figure 9(a) –9(b) for the Karadag fibre model in the midmyocardial region.

Figure 9. Effect of sheets on Lagrangian strains.

Figure 9

Average midmyocardial (a) Inline graphic and (b) Inline graphic with transverse isotropy, orthotropy with the linear sheet model and orthotropy with bimodal sheet model, in the case of Karadag fibre model.

Discussion

In the previous section, results are presented of a systematic computational study into the effect of tissue microstructure on contraction, using a simplified model of rat left ventricle. It consists of a series of electromechanical simulations carried out on a thick-walled truncated ellipsoid, with the aim of quantifying the combined effect of different models for fibre and sheet directions with different tissue passive behaviours during simulated active contraction. Sixteen global fibre models were compared against a subject-specific model. The impact of sheets was also investigated by comparing transversely isotropic and orthotropic material properties as well as two models for the sheet orientation, namely a linear and a bimodal model.

In the development of the model we tried to be as species-specific as possible in all the components, with the exception of the reduced range for the cavity pressure, as described in Methods and further discussed later on. The geometry has dimensions taken from rat cine-MRI scans, the parameters of tissue electrophysiology are based on measurements in rat. Regarding the AP model, we preferred the mouse model of Wang and Sobie [21] over other available rat models for reasons of computational efficiency. Of course, the ventricular activation sequence with simulated apical pacing differs from normal in vivo patterns that were present during cine-MRI. However, as we compared pre-activation (diastole) with peak contraction (systole), we believe that this is unlikely to have had a major effect on our findings related to steady-state comparisons. As for the mechanics, there are rat-specific biophysical contraction models. However, we preferred to use the model of Kerckhoffs et al. [24] as it allowed us to adjust its parameters in a controlled manner while retaining a good description of the contractile behaviour of the myocyte. The stiffness parameters of the exponential constitutive law (eqn. (5)) for material orthotropy are taken from a study carried out on canine hearts by Usyk et al. [4]. In their paper Usyk et al. explore the stiffness parameters space in order to study their effect on mechanics, providing a range of variation for each of the parameters. We chose the orthotropic parameter set that showed magnitudes comparable with the values reported for rat in transverse isotropy by Omens et al. [32]. This was necessary because we did not find published orthotropic stiffness parameters values for exponential constitutive laws for rat. We obtained the stiffness parameters for transverse isotropy by averaging the orthotropic ones in the sheet and normal directions. We ensured that the two parameters sets for orthotropy and transverse isotropy had the same magnitudes in order to minimise the effect of parameters magnitude and explore only that of material symmetry.

Various measures were considered, grouped into global and local parameters, in order to study the effect of the fibre model, material law and sheet model on contraction. For the global measures, ejection fraction (Inline graphic), wall thickening (Inline graphic) and base-to-apex shortening (Inline graphic) were compared. We chose these measures because they are representative of the main features of cardiac function in the left ventricle. Furthermore, most electromechanical models do not currently predict Inline graphic and Inline graphic well enough. The global measures are consistently affected by the fibre model and material law, while they show smaller variation when changing the sheet model. The only exception seems to be the downward trend of Inline graphic in the case of Inline graphic (Figure 3(b)). We believe this is due to an inverse correlation between the magnitude of Inline graphic and the rate of increase of Inline graphic. In other words, the more Inline graphic increases in magnitude for a given value of Inline graphic and increasing values of Inline graphic, the smaller the increase in Inline graphic. This effect can be seen in Figure 3(b), where the steepness of the Inline graphic curves decreases consistently going from n = 3 to n = 0.5. This observation suggests that there is a trade-off between shortening and efficiency of the pumping function. Too much shortening is as detrimental to pumping function as elongation. Regarding the fibre models, the subject-specific fibre model does not produce values of the global measures that are notably closer to the measured values than those obtained using the best global fibre models. In particular, among the fibre models, those with low exponent Inline graphic and high torsion angle Inline graphic (such as Sn1R70 and Sn1R80) produce values of the global metrics that are comparable or better than those of the subject specific model. These results are encouraging in that they confirm that, in the case of the Streeter-like fibre models (see eqn. (1)), the exponent Inline graphic describes fibres in rat left ventricle better than other values, in accordance with previous comparisons of rule-based versus DT-MRI-derived fibres in rat [33]. In general, the predicted values for Inline graphic and Inline graphic, although being at the physiological range ([30],[13]), are lower than the measured ones, while some global fibre models are able to match or exceed the measured value for Inline graphic. Changing from transversely isotropic to orthotropic material properties (with the linear sheet model) increases the predicted values of the three metrics, but this is not enough to match the measured values for Inline graphic and Inline graphic. Within the orthotropic setting, no significant effect was seen on Inline graphic, while for Inline graphic and Inline graphic the bimodal model case gave results intermediate between those for transverse isotropy and orthotropy with the linear sheet model.

The Lagrangian strains Inline graphic, Inline graphic and Inline graphic are used as local measures. The Karadag subject-specific model has strain traces close to those of global fibre models with lower exponent Inline graphic and higher angle Inline graphic. In particular the models Sn1R70 and Sn1R80 are those that in terms of strains give the most similar results to the Karadag model. This confirms our findings in the analysis of the global metrics. Interestingly, the fibre models that produce higher magnitude of strains (that is higher Inline graphic and lower Inline graphic) are the same that gave poorest results in terms of the global metrics. Conversely, this means that fibre models such as Karadag, Sn1R70 and Sn1R80 are able to convert smaller strains into more efficient cardiac function. Changing from transversely isotropic to orthotropic material properties has a negligible effect on Inline graphic, a small effect on Inline graphic, while a more pronounced change was evident in Inline graphic. In particular, introducing the bimodal model increases the average magnitude of Inline graphic in the midmyocardial region by Inline graphic with respect to both transverse isotropy and orthotropy with the linear sheet model. This is as expected since the effect of introducing orthotropy is more likely to have a larger effect on Inline graphic rather than Inline graphic. In general, the results show strain traces and magnitudes close to those reported in the literature for rodents [29] [31], especially in the case of Inline graphic, as shown in Figures 6(b), 7(b) and 8(b), for Inline graphic, Inline graphic and Inline graphic traces, respectively, for the simulation with Karadag fibre model and transverse isotropy.

It is important to discuss the limitations of our model. (a) The use of a simplified geometry: the natural geometrical variability of the left ventricle is not taken into account in this study, including the lack of a neighbouring contracting chamber (right ventricle), or of papillary muscles whose orientation is predominantly axial. Previous studies suggest this might not bring a significant improvement [9], nonetheless, it would be interesting to investigate if the conclusions about the subject-specific vs global fibre models hold also in the case of a subject-specific geometry. (b) The electrical activation pattern: the apical region was chosen for the electrical stimulation in order to mimic the apex-to-base direction of the electrical activation in the left ventricle. This type of activation pattern is consistent, for example, with the type of external stimulation employed in the Langendorff-perfused experiments. However, this is not what happens in the living heart [34]. Evaluating the influence of changes in activation pattern on predicted left ventricular mechanics would be an interesting application of our model. (c) The ad-hoc procedure to estimate the pre-P mesh prior to applying the pressure load: this step should be tackled in a more automatic and rigorous approach, by solving an inverse problem. (d) The reduced range of pressures applied in the model: this is probably the most important limitation of the model as pressure is one of the best characterised physiological parameters of the heart. If we compare the results of the preliminary study we carried out using the model without pressure [17] with those presented here, we find similar trends in the global measures for the different fibre models. By introducing pressure in the model, we find that the magnitude of those measures increases significantly on average, meaning that the pressure boundary condition is fundamental for the efficiency of the simulated pumping function, but does not interfere with the effect of the different fibre models on contraction. The use of a reduced pressure range is the result of the best compromise between realistic contraction patterns and physiological pressures in the model. With the current modelling setting, the use of realistic (based on laboratory measurements) material properties in combination with the chosen contraction model forces the pressure to be reduced to avoid non-physiological contraction patterns. The alternative would be to enforce physiological pressures by modifying the material properties (which would no longer be based on experimental measurements) and fully re-parametrizing the contraction model (for which experimental data would not be available). We chose the first approach for several reasons. The first is to reduce the degrees of freedom of the model, setting one parameter (the pressure) rather than a set of mechanical properties. Another is that of consistency with existing literature, which allows us to compare results directly. Still, as mentioned above, this is a major study limitation. As such, it identifies a key direction for further study, reinforcing an important role of quantitative models as a drivers of scientific progress [35], and highlighting that currently available data, implemented mechanisms, and attempted explanations are insufficient to fully reproduce reality. (e) The lack of the transverse angle in the fibre model definitions: this angle regulates the level of crossover of fibres which may be important in a correct prediction of shear strains [16]. (f) Cross-fibre generation of active tension: at the tissue level, the model generates active tension along the fibre direction only. Experimental studies have shown that there is a certain amount of active tension generated in the cross-fibre plane as well [36], and some important electromechanical simulation studies already take this into consideration [4], [16]. In particular, Bovendeerd et al. [16] have shown that including the cross-fibre active tension generation into their model improved the prediction of Inline graphic. (g) The fibre models considered: the choice of rule-based and subject-specific fibre models analysed was necessarily reduced in order to focus on a specific scientific question. It is important to note that we did not consider asymmetrical fibre angle intervals for the rule-based model, which have been found experimentally [1] and might affect, at least locally, the predicted contraction patterns. However, we expect that their effect would remain within the ranges predicted by the fibre models already examined. Eriksson et al [37], for example, have compared symmetric and asymmetric transmural fibre angles for a linear rule-based fibre model and found generally consistent predictions in the metrics considered. Another important aspect we did not take into account is the variability in subject-specific fibre distribution. Karadag et al [5] report standard deviations of Inline graphic 15 degrees for Inline graphic and Inline graphic 0.25 for Inline graphic. It would be interesting to investigate the inter-subject variability of the Karadag fibre model and its effect on contraction patterns in the future. (h) The sheet orientation models: we used two simplified models of sheet transmural variation, neglecting the great regional variability in terms of sheet patterns that has been found experimentally, and that is thought to give rise to a concertina-like re-arrangement during contraction and relaxation [13]. Overall the impact of sheet inclusion in our study was small, with the exception of changes in Inline graphic. It could be argued that this could be due to the high stiffness in the sheet direction imposed by the constitutive law. However, preliminary tests with different magnitudes of the stiffness parameters did not show such a substantial variation in the global metrics results to make us believe that this problem could be addressed simply by tuning the constitutive law parameters. Furthermore, introducing the more realistic bimodal sheet model did not affect the global metrics in the way we expected. For example, it did not cause a significant increase in the predicted wall-thickening, while it has been shown that this mechanism is directly related to sheets dynamics [14].

To conclude, we developed and tested an electromechanical model and performed a computational study of the impact of tissue microstructure on contraction of the left ventricle in rat. We showed that the model predicts values of global metrics that are within physiological ranges but, except for Inline graphic, they fall below the values measured on cine-MRI scans. Introducing subject-specific fibre models, as opposed to global fibre models, does not provide a substantial increase in Inline graphic and Inline graphic values. The analysis of strains confirmed that the subject-specific fibre model gave predictions similar to linear global fibre models with higher rotation angle. Changing from transverse isotropy to orthotropy in the passive behaviour, therefore introducing the effect of tissue anisotropy due to the sheets, improves the predictions of Inline graphic and Inline graphic, but they still remain lower than the measured values. This means that including the sheet orientation in the model is an important factor, and a more detailed representation of angular re-orientation of sheet material may be required. Therefore, we believe that, within the current modelling framework, the subject-specific approach in fibre definition by itself is not able to compensate for the model limitations that are believed to come from the underestimation of sheet dynamics, and that further investigation of the dynamics of sheet orientation should be carried out and novel approaches developed in order to fully represent its effect on cardiac mechanics.

Acknowledgments

The authors would like to thank Dr Rebecca Rowland for providing the image of the histological sample shown in Figure 1(f).

Funding Statement

The work presented here was supported by BBSRC grants E003443 and BB/I012117, by the British Heart Foundation New Horizon grant NH/13/30238, and by EPSRC grant EP/J013250/1. VC was partially funded by the EPSRC and would like to thank the Systems Biology Doctoral Training Centre. RB was funded by the EU FP7 AirPROM project (grant agreement no. 270194). JES is a BHF Senior Basic Science Research Fellow. PK acknowledges additional support by the British Heart Foundation and the European Research Council. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

References

  • 1. Streeter DD, Spontnitz HM, Patel D, Ross J, Sonnenblick EH (1969) Fiber orientation in the canine left ventricle during diastole and systole. Circ Res 24: 339–347. [DOI] [PubMed] [Google Scholar]
  • 2. LeGrice IJ, Smaill BH, Chai LZ, Edgar SG, Gavin JB, et al. (1995) Laminar structure of the heart: ventricular myocyte arrangement and connective tissue architecture in the dog. Am J Physiol Heart Circ Physiol 269: H571–H582. [DOI] [PubMed] [Google Scholar]
  • 3. Gilbert SH, Benson AP, Li P, Holden AV (2007) Regional localisation of left ventricular sheet structure: integration with current models of cardiac fibre, sheet and band structure. Eur J Cardiothorac Surg 32: 231–249. [DOI] [PubMed] [Google Scholar]
  • 4. Usyk TP, Mazhari R, McCulloch AD (2000) Effect of Laminar Orthotropic Myofiber Architecture on Regional Stress and Strain in the Canine Left Ventricle. J Elast 61: 143–164. [Google Scholar]
  • 5.Karadag IE, Bishop M, Hales PW, Schneider JE, Kohl P, et al. (2011) Regionally optimised mathematical models of cardiac myocyte orientation in rat hearts. In: FIMH. Springer, volume 6666 of LNCS, pp. 294–301.
  • 6. Scollan DF, Holmes A, Winslow R, Forder J (1998) Histological validation of myocardial microstructure obtained from diffusion tensor magnetic resonance imaging. Am J Physiol Heart Circ Physiol 275: H2308–H2318. [DOI] [PubMed] [Google Scholar]
  • 7. Kroon W, Delhaas T, Bovendeerd PH, Arts T (2009) Computational analysis of the myocardial structure: Adaptation of cardiac myofiber orientations through deformation. Med Image Anal 13: 346–353. [DOI] [PubMed] [Google Scholar]
  • 8. Burton RA, Plank G, Schneider JE, Grau V, Ahammer H, et al. (2006) Three-Dimensional models of individual cardiac histoanatomy: Tools and challenges. Ann N Y Acad Sci 1080: 301–319. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Geerts L, Kerckhoffs R, Bovendeerd P, Arts T (2003) Towards patient specific models of cardiac mechanics: A sensitivity study. In: FIMH, Springer, volume 2674 of LNCS. pp. 1006–1007.
  • 10. Vadakkumpadan F, Arevalo H, Prassl AJ, Chen J, Kickinger F, et al. (2010) Image-based models of cardiac structure in health and disease. Wiley Interdiscip Rev Syst Biol Med 2: 489–506. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Aguado-Sierra J, Krishnamurthy A, Villongco C, Chuang J, Howard E, et al. (2011) Patient-specific modeling of dyssynchronous heart failure: a case study. Prog Biophys Mol Biol 107: 147–155. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12. Coppola BA, Omens JH (2008) Role of tissue structure on ventricular wall mechanics. Mol Cell Biomech 5: 183–196. [PMC free article] [PubMed] [Google Scholar]
  • 13. Hales PW, Schneider JE, Burton RA, Wright BJ, Bollensdorff C, et al. (2012) Histo-anatomical structure of the living isolated rat heart in two contraction states assessed by diffusion tensor MRI. Prog Biophys Mol Biol 110: 319–330. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14. Cheng A, Nguyen TC, Malinowski M, Daughters GT, Miller DC, et al. (2008) Heterogeneity of Left Ventricular Wall Thickening Mechanisms. Circulation 118: 713–721. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Hooks DA, Trew ML, Caldwell BJ, Sands GB, LeGrice IJ, et al. (2007) Laminar arrangement of ventricular myocytes influences electrical behavior of the heart. Circ Res 101: e103–e112. [DOI] [PubMed] [Google Scholar]
  • 16. Bovendeerd PHM, Kroon W, Delhaas T (2009) Determinants of left ventricular shear strain. Am J Physiol Heart Circ Physiol 297: H1058–H1068. [DOI] [PubMed] [Google Scholar]
  • 17.Carapella V, Bordas R, Pathmanathan P, Schneider JE, Kohl P, et al. (2013) Effect of fibre orientation optimisation in an electromechanical model of left ventricular contraction in rat. In:FIMH, Springer, volume 7945 of LNCS. pp. 46–53.
  • 18. Plank G, Burton RA, Hales P, Bishop M, Mansoori T, et al. (2009) Generation of histo-anatomically representative models of the individual heart: tools and application. Philos Trans A Math Phys Eng Sci 367: 2257–2292. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19. Geuzaine C, Remacle JF (2009) Gmsh: a three-dimensional finite element mesh generator with built-in pre- and post-processing facilities. Int J Numer Methods Eng 79: 1309–1331. [Google Scholar]
  • 20. Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, et al. (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the cardiac imaging committee of the council on clinical cardiology of the american heart association. Circulation 105: 539–542. [DOI] [PubMed] [Google Scholar]
  • 21. Wang LJ, Sobie EA (2008) Mathematical model of the neonatal mouse ventricular action potential. Am J Physiol Heart Circ Physiol 294: H2565–H2575. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22. Satoh H, Delbridge LM, Blatter LA, Bers DM (1996) Surface:volume relationship in cardiac myocytes studied with confocal microscopy and membrane capacitance measurements: species- dependence and developmental effects. Biophys J 70: 1494–1504. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Bourgeois EB, Fast VG, Collins RL, Gladden JD, Rogers JM (2009) Change in conduction velocity due to fiber curvature in cultured neonatal rat ventricular myocytes. IEEE Trans Biomed Eng 56: 855–861. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24. Kerckhoffs RC, Bovendeerd PH, Kotte JC, Prinzen FW, Smits K, et al. (2003) Homogeneity of Cardiac Contraction Despite Physiological Asynchrony of Depolarization: A Model Study. Ann Biomed Eng 31: 536–547. [DOI] [PubMed] [Google Scholar]
  • 25. Connelly KA, Prior DL, Kelly DJ, Feneley MP, Krum H, et al. (2006) Load-sensitive measures may overestimate global systolic function in the presence of left ventricular hypertrophy: a comparison with load-insensitive measures. American Journal of Physiology - Heart and Circulatory Physiology 290: H1699–H1705. [DOI] [PubMed] [Google Scholar]
  • 26.Niederer SA, Smith NP (2009) The role of the frankstarling law in the transduction of cellular work to whole organ pump function: A computational modeling analysis. PLoS Comput Biol 5 : Available: http://dx.doi.org/10.1371/journal.pcbi.1000371. Accessed 2013 Oct 1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Mirams GR, Arthurs CJ, Bernabeu MO, Bordas R, Cooper J, et al. (2013) Chaste: An open source c++ library for computational physiology and biology. PLoS Comput Biol 9 : Available: http://dx.doi.org/10.1371/journal.pcbi.1002970. Accessed 2013 Oct 1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28. Pathmanathan P, Whiteley J (2009) A Numerical Method for Cardiac Mechanoelectric Simulations. Ann Biomed Eng 37: 860–873. [DOI] [PubMed] [Google Scholar]
  • 29. Daire JL, Jacob JP, Hyacinthe JN, Croisille P, Montet-Abou K, et al. (2008) Cine and tagged cardiovascular magnetic resonance imaging in normal rat at 1.5 t: a rest and stress study. 10: 1–10. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30. Wise RG, Huang CL, Gresham GA, Al-Shafei AIM, Carpenter TA, et al. (1998) Magnetic resonance imaging analysis of left ventricular function in normal and spontaneously hypertensive rats. J Physiol 513: 873–887. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Zhong X, Gibberman L, Spottiswoode B, Gilliam A, Meyer C, et al. (2011) Comprehensive cardiovascular magnetic resonance of myocardial mechanics in mice using three-dimensional cine DENSE. J Cardiovasc Magn Reson 13 : 83+. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32. Omens JH, MacKenna DA, McCulloch AD (1993) Measurement of strain and analysis of stress in resting rat left ventricular myocardium. J Biomech 26: 665–676. [DOI] [PubMed] [Google Scholar]
  • 33.Bishop M, Hales P, Plank G, Gavaghan D, Schneider J, et al. (2009) Comparison of Rule-Based and DTMRI-derived fibre architecture in a whole rat ventricular computational model. In: FIMH, Springer, volume 5528 of LNCS. pp. 87–96.
  • 34. Durrer D, Van Dam RTH, Freud GE, Janse MJ, Meijler FL, et al. (1970) Total excitation of the isolated human heart. Circulation 41: 899–912. [DOI] [PubMed] [Google Scholar]
  • 35. Kohl P, Crampin EJ, Quinn TA, Noble D (2010) Systems biology: an approach. Clinical pharmacology and therapeutics 88: 25–33. [DOI] [PubMed] [Google Scholar]
  • 36. Lin DH, Yin FC (1998) A multiaxial constitutive law for mammalian left ventricular myocardium in steady-state barium contracture or tetanus. J Biomech Eng 120: 504–517. [DOI] [PubMed] [Google Scholar]
  • 37. Eriksson TSE, Prassl AJ, Plank G, Holzapfel GA (2013) Inuence of myocardial fiber/sheet orientations on left ventricular mechanical contraction. Mathematics and Mechanics of Solids 18: 592–606. [Google Scholar]

Articles from PLoS ONE are provided here courtesy of PLOS

RESOURCES