Abstract
Recent restrictions on the testing of cosmetic ingredients in animals have resulted in the need to test the genotoxic potential of chemicals exclusively in vitro prior to licensing. However, as current in vitro tests produce some misleading positive results, sole reliance on such tests could prevent some chemicals with safe or beneficial exposure levels from being marketed. The 3D human reconstructed skin micronucleus (RSMN) assay is a promising new in vitro approach designed to assess genotoxicity of dermally applied compounds. The assay utilises a highly differentiated in vitro model of the human epidermis. For the first time, we have applied automated micronucleus detection to this assay using MetaSystems Metafer Slide Scanning Platform (Metafer), demonstrating concordance with manual scoring. The RSMN assay’s fixation protocol was found to be compatible with the Metafer, providing a considerably shorter alternative to the recommended Metafer protocol. Lowest observed genotoxic effect levels (LOGELs) were observed for mitomycin-C at 4.8 µg/ml and methyl methanesulfonate (MMS) at 1750 µg/ml when applied topically to the skin surface. In-medium dosing with MMS produced a LOGEL of 20 µg/ml, which was very similar to the topical LOGEL when considering the total mass of MMS added. Comparisons between 3D medium and 2D LOGELs resulted in a 7-fold difference in total mass of MMS applied to each system, suggesting a protective function of the 3D microarchitecture. Interestingly, hydrogen peroxide (H2O2), a positive clastogen in 2D systems, tested negative in this assay. A non-genotoxic carcinogen, methyl carbamate, produced negative results, as expected. We also demonstrated expression of the DNA repair protein N-methylpurine-DNA glycosylase in EpiDerm™. Our preliminary validation here demonstrates that the RSMN assay may be a valuable follow-up to the current in vitro test battery, and together with its automation, could contribute to minimising unnecessary in vivo tests by reducing in vitro misleading positives.
Introduction
An understanding of the genotoxic effects of chemicals in humans is imperative for the prediction of genotoxic potential resulting from chemical exposure. This is particularly important for chemicals utilised in products and treatments with repeated human exposure, such as cosmetics, pharmaceuticals and food. Further, following the 7th Amendment to the Cosmetics Directive in 2009, use of laboratory animals in cosmetics testing has been banned in the European Union (1). Due to the fact that in vivo testing has previously been heavily relied upon to confirm positive results of in vitro genotoxicity assays, it is now vital that in vitro tests alone can accurately identify human carcinogens (2). However, in vitro tests often exaggerate toxic effects when compared with in vivo results, possibly due to lack of normal human tissue structure or dosing strategies being unrealistic. Further, some in vitro tests have used p53-deficient cell lines, which tend to be over-sensitive for genotoxic endpoints compared to normal human cells, contributing to misleading positives (3). Therefore, improvement of the current in vitro test battery is urgently required, to allow chemicals with safe, or even beneficial, human exposure levels to be identified and subsequently utilised in products and treatments (2).
3D EpiDerm™ reconstructed human skin models
An alternative to the current genotoxicity test battery is the inclusion of in vitro methods that mimic human tissues, such as EpiDerm™ 3D reconstructed human skin models (1). Such models are predicted to better reflect the microarchitecture of human tissues and more accurately recapitulate human metabolism than cell lines. They are also predicted to exhibit near-normal DNA repair and cell cycle control (1,4). It has been demonstrated that 87% of tested xenobiotic metabolising enzymes were expressed consistently between the EpiDerm™ model and human skin, further supporting the relevance to the human condition (5). As skin is an organ frequently exposed directly to chemicals, particularly via dermal application of cosmetics and occupational exposure, the EpiDerm™ models represent one of the most common human chemical exposure routes (1). The stratum corneum of EpiDerm™ provides more relevant exposure conditions for target cells during topical dosing, avoiding the non-physiological concentrations of test chemical that are often used in in vitro tests (1,4). Therefore, an advantage of such models is that realistic concentrations of chemicals may be tested, with any associated kinetic effects that may occur as the test article diffuses from the epidermal surface to the basal layer of proliferating keratinocytes (4). Additionally, the reconstructed skin micronucleus (RSMN) assay has been shown to detect some chemicals that require metabolic activation (6). Previous studies utilising this assay have established that it is reproducible between laboratories in the USA and Europe, and also that it correctly classifies chemicals into either genotoxic or non-genotoxic carcinogens (1,2,5). Application of test chemicals to the medium instead of topically may also serve as a basic model of systemic exposure to chemicals. The hair dye ingredient, p-phenylenediamine (PPD), has previously been added to medium of EpiDerm™ models by Hu et al. (7), who noted cytotoxicity and evidence of PPD metabolites (7). An aim of this study was to expand the database for the RSMN assay in another European laboratory and to explore medium exposure in more depth. To our knowledge, this is the first publication exploring the use of models from MatTek’s Slovakia laboratory.
Exploring genotoxic dose responses in 3D systems
In recent years, experimental techniques for the detection of genotoxicity have become more sensitive, allowing more accurate detection of genotoxic dose responses. This has led to non-linear dose responses, for example, threshold dose-responses, being described (8,9). The demonstration of non-linear dose responses has led to the suggestion that low doses of a genotoxin may not pose a risk to health, unlike higher doses. Cellular resistance to genetic damage at low doses may be due to homeostatic maintenance by DNA repair (10), insufficient levels of chemical traversing cell membranes (bioavailability) or the genotoxin reacting with molecules within the cytoplasm and surroundings (8). As most human exposures occur at low doses, it is vital that low-dose effects are studied. While genotoxic thresholds have been well characterised in 2D cell culture, they have not yet been fully investigated with 3D approaches. Furthermore, previous studies involving the 3D EpiDerm™ models have been primarily used for evaluating whether chemicals induce a positive response for micronuclei in this assay, rather than for obtaining complete dose responses. The parameters—no observed genotoxic effect level and lowest observed genotoxic effect level (LOGEL)—are currently used to define non-linear dose responses at low doses (9) but require substantial statistical power. Therefore, by applying an automated micronucleus scoring platform, as discussed in the next section, to the RSMN assay, such analyses of the low-dose region can be performed in 3D cultures. Given the aforementioned advantages of the RSMN assay, defining the low-dose region in primary cells with 3D microarchitecture maybe more robust. With recent interest in the effects of low-dose genotoxicity, this is the first study to investigate the effects in the low-dose region (i.e. a low-dose range which is several fold lower than that for toxic effects) in 3D culture. The non-linear parameters will be used as a convenient comparison between 2D and 3D and not to define thresholds for the chemicals used. We have investigated low doses of three direct-acting, model genotoxins that have previously tested positive for genotoxic thresholds in vitro in human lymphoblastoid cell lines (9,11).
Use of the Metafer Slide Scanning Platform with the RSMN assay
While the RSMN assay has successfully detected genotoxicity of some chemicals in 3D EpiDerm™ models in previous studies, the scoring for micronuclei was completed manually. In this study, an automated approach, using the MetaSystems Metafer Slide Scanning Platform (Metafer), was introduced for the first time to detect micronuclei in keratinocytes isolated from 3D EpiDerm™ models. As manual scoring is laborious and partially subjective, use of the Metafer to identify micronucleus induction in 3D EpiDerm™ keratinocytes minimises delays associated with time-consuming manual scoring and reduces subjectivity (12). The automated approach also results in more cells being scored than with manual scoring. Therefore, we investigated the application of the Metafer in the RSMN assay, using the RSMN assay’s currently recommended harvest protocol (13).
The objective of this study was to evaluate the use of the RSMN assay in our laboratory for characterisation of the genotoxicity dose responses for low doses of four chemicals of diverse mechanism of action and to validate the Metafer system for use as a more efficient method for micronucleus scoring in keratinocytes from the RSMN assay.
Materials and methods
Chemicals
Chemicals were purchased from Sigma-Aldrich (Gillingham, UK) and stored according to the manufacturer’s instructions.
EpiDerm™ tissues
Tissues were purchased from MatTek In Vitro Life Science Laboratories (Bratislava, Slovakia) and ordered 3 weeks in advance. All tissues shipped to Swansea were derived from cells from the same donor (Keratinocyte strain: 4F1188), as confirmed by MatTek. There are 24 tissues in one batch, and this work represents data generated from ~28 individual batches and, therefore, shipments. Following overnight shipping, tissues were kept at 4°C until assay commencement, with the time spent at 4°C standardised between batches to ensure that transfer to 37°C was completed at the same time on the day of arrival.
Assessing growth of EpiDerm™ during the RSMN assay
Each day during a typical RSMN assay, EpiDerm™ tissues were sectioned and stained using haematoxylin and eosin (H&E) at Singleton Hospital, Swansea. Sections were analysed using the ×100 objective of an Olympus BX51 light microscope. Size of the stratum corneum was taken as an indicator of cell growth and differentiation (Figure 1).
RSMN assay
Tissue inserts were inspected for morphological defects, such as blisters. Excess moisture on the surface of the tissue was removed by gentle blotting with sterile gauze. Tissues were placed into 6-well plates with each well containing 900 µl of new maintenance medium (NMM) (MatTek) pre-warmed to 37°C. Tissues were incubated overnight under standard culture conditions (37°C, 5% CO2 humidified atmosphere). After 16h, the NMM within the well was aspirated and replaced with 900 µl sterile 37°C NMM containing 3 µg/ml cytochalasin B (cytoB) (Sigma-Aldrich). Test articles were dissolved and diluted in acetone (Fisher Scientific, Loughborough, UK). Ten microlitres of test article was administered onto the topical surface using a positive displacement pipette and the plate rotated for even distribution. Tissues were incubated under standard conditions for 24h. On Day 3, the treatment protocol was repeated and the models incubated for a further 24h with fresh test article.
All tissues were harvested within 48±3h after the first treatment, according to Curren et al. (14) and as mentioned previously. For successful trypsin digestion, each tissue was submerged in 5ml Dulbecco’s phosphate-buffered saline (DPBS; Invitrogen, Paisley, UK) for 15min at room temperature (RT) prior to transfer to 5ml ethylenediaminetetraacetic acid (EDTA), pH 8.0 (Ambion, Warrington, UK), diluted to 1mg/ml in DPBS, for 15min at RT. The tissue inserts were blotted before transfer to 1ml 0.25% Trypsin–EDTA pre-warmed to 37°C (Invitrogen). An additional 400 µl of trypsin solution was added directly into the insert and incubated at 37°C for 15min. After this time, tissues were carefully removed from the insert using sterile fine forceps and placed in fresh trypsin solution (1ml). To maximise cell recovery, the insert was rinsed thoroughly and the aforementioned 400 µl was combined with the 1ml in the well. The resulting 1.4ml of the cell suspension was added to 1ml Dulbecco’s modified Eagle’s medium (Invitrogen) (supplemented with foetal bovine serum (10%) (Invitrogen)) to inactivate trypsin.
For in-medium dosing, 10 µl of a stock concentration of methyl methanesulfonate (MMS) was added directly into the medium (890 µl), with the dilution factor accounted for, and mixed. For the mononucleate assay, cytoB was not added to the NMM and tissues were harvested 24h later than for the binucleate assay.
Cell fixation
Cell suspensions were centrifuged at 100 × g for 5min and the supernatant aspirated. One millilitre of potassium chloride (KCl, 75mM; Sigma-Aldrich) pre-warmed to 37°C was added slowly to the pellet. After 3min at RT, 3ml of fixative (3:1 methanol:acetic acid; Fisher Scientific) chilled to 4°C was added. Cells were kept in fixative at 4°C awaiting slide preparation.
Slide preparation and staining for manual scoring
Cells in fixative were centrifuged at 100 × g for 5min at 4°C, the supernatant removed and 5 µl of the cell pellet gently pipetted onto a clean, dry slide as a concentrated dot to minimise cell spreading. Following air drying, slides were stained for 3min using acridine orange (Sigma-Aldrich) diluted to 40 µg/ml in Gurr phosphate buffer (0.1M NaH4PO4, 0.1M Na2HPO4) at pH 6.8 (Gibco). Slides were rinsed in Gurr phosphate buffer and left to de-stain for 30min in fresh Gurr phosphate buffer. Micronucleus frequencies were assessed by visualisation under UV light on an Olympus BX50 microscope, using ×100 objective. One thousand binucleated cells were scored for the presence of micronuclei and cell viability assessed by binucleate frequency in 500 cells. Cells with a cytoplasm stained green were excluded from binucleate and micronucleus scores, as these are highly differentiated keratinocytes.
Slide preparation and staining for automated scoring
For the comparison of automated and manual scoring methodologies, slides for automated scoring were prepared from the same cell pellet used for manual scoring. Following preparation for manual scoring, 200 µl fixative was added and 100 µl of cell suspension was distributed over the entire surface of a wet slide cleaned using 70% ethanol prior to soaking in water. Cell density was adjudged under a light microscope and, if required, the volume of fixative amended accordingly. Once air dried, slides were stored at −20°C awaiting staining. Slides were evenly covered with 20 µl Vectashield Mounting Medium with 4′,6-diamino-2-phenylindole (Vector Laboratories, Peterborough, UK), coverslip applied and kept in the dark for 15min prior to automated scoring using the Metafer system
Assessment of micronucleus frequency using Metafer
Micronucleus detection in binucleated cells was performed using the parameters specified by A. L. Seager et al. (13). As described by Seager et al., parameters for analysis of micronuclei were developed using cell lines. In our studies, Metafer parameters developed for cell lines were unchanged in the analysis of micronuclei in cells from EpiDerm™. Metafer was allowed to systematically scan the slide using the ×10 objective and following scanning, all binucleated cells identified as containing a micronucleus were confirmed by reanalysis of the image by a trained scorer using the ×100 objective. All images of binucleates in the on-screen gallery, which were predicted to not contain micronuclei by Metafer, were also confirmed to be true negatives. Gallery images that appeared to contain a micronucleus were assessed further under ×100 objective (Supplementary Figure 1, available at Mutagenesis Online). Therefore, with the need for by-eye confirmation, Metafer analysis could perhaps be considered to currently be a semi-automated scoring approach, rather than fully automated. The criteria for classification of micronuclei, as recommended by Fenech et al. (15), were used to characterise micronuclei. Binucleate frequency was scored manually under a Carl Zeiss Axio Imager fluorescence microscope and micronucleus frequency scored using this microscope with the Metafer 4 software, version 3.5 (MetaSystems, Altlussheim, Germany). Separate software for the analysis of frequency of mononucleates, binucleates and multinucleates for cell lines is available for Metafer but was not used in these studies. Approximately 500 cells were scored for binucleate frequency per tissue and 1000 cells were scored for presence of micronuclei. A final micronucleus frequency score was generated based on the number of true micronucleus events following by-eye confirmation. A previously optimised mononucleate classifier was used to detect mononucleates.
Preparation of positive control
Two 10 µl applications of a 6 µg/ml solution of mitomycin-C (MMC; 0.1875 µg/cm2) over 48h were distributed uniformly over the 0.64cm2 topical surface area. This gave consistent statistically significant increases in micronucleus frequencies over solvent (negative) controls (2).
Collaboration with Procter and Gamble Laboratories
To further compare Metafer and manual scoring approaches, Procter and Gamble (P&G), a company that has been involved with validation of the RSMN assay, shipped slides to Swansea University for Metafer analysis. The assay was completed in P&G’s laboratories in the USA and slides were prepared for Metafer analysis using the fixation and slide preparation protocol described previously. Slides were shipped coded to Swansea University, stained and analysed using Metafer, as outlined previously. Comparative acridine orange (manual) scoring was completed in P&G’s laboratories.
DNA repair gene expression analysis
Following the second chemical treatment, cells were harvested as previously outlined, for tissues treated topically with 0, 1000 and 1900 µg/ml MMS. Following centrifugation at 100 × g, supernatant was removed and total RNA extracted from the pellet using the RNeasy Kit (Qiagen, Crawley, UK) and RNase-free DNase Set (Qiagen). Eluted RNA solution was quantified using the NanoDrop (ND 1000) Spectrophotometer, software version 3.1.2. Synthesis of complementary DNA (cDNA) was performed via reverse transcription of 1 µg RNA using the Quantitect Reverse Transcription Kit (Qiagen) and BioRad T100 Thermal Cycler using conditions specified by the manufacturer. The polymerase chain reaction (PCR) was performed for each cDNA sample, using the GoTaq® Flexi DNA Polymerase kit (Promega, Southampton, UK). N-methylpurine-DNA glycosylase (MPG) primers (Sigma-Aldrich): Forward primer: GGTCCGAGTCCCACGAAGCC. Reverse primer: CTGCATGACCTGGGCCCCG. β–actin (housekeeping gene): Forward primer: GATGGCCACGGCTGCTTC. Reverse primer: TGCCTCAGGGCAGCGGAA. Polyacrylamide gels (5.4%) were cast and DNA polyacrylamide gel electrophoresis (PAGE) performed at 170V for 30min. DNA was stained by washing the gel for 7min in 1g/l silver nitrate solution (Sigma-Aldrich), followed by a 3min wash in sodium hydroxide/formaldehyde solution (Sigma-Aldrich) until the bands were visible, followed by submersion in ddH2O.
Micronucleus detection in a human lymphoblastoid cell line
TK6 cells were seeded at a density of 1×105 cells/ml in RPMI 1640 medium (Gibco, Paisley, UK) [supplemented with 10% horse serum (Gibco) and 1% glutamine (Gibco)]. After 24h incubation at 37°C and 5% CO2, cells were dosed for 24h with MMS diluted in H2O. Following the dosing period, medium was replaced with fresh medium and a further 24h recovery period was allowed. Samples were then harvested using the standard Metafer harvest protocol, as described by A. L. Seager et al. (13). A mononucleate classifier was used to detect micronuclei in mononucleates and determine micronucleus frequency, using the aforementioned Metafer protocol.
Statistical analysis
A two-tailed Fisher’s exact test was used to assess whether statistically significant (P ≤ 0.05) differences exist between control and treated sample micronucleus frequencies and to predict LOGELs. Doses demonstrating a statistically significant increase in micronuclei above control levels are indicated on graphs by an asterisk. All error bars represent standard deviation around the mean of three biological replicates. Pearson’s product moment correlation was used to determine whether a correlation exists between two separate treatments, where a correlation coefficient, r, of +1 is a total positive correlation, 0 is no correlation and −1 is a total negative correlation. The Broken Stick Model (16) was used to predict whether the data fitted a threshold or linear dose response for genotoxicity. Unless otherwise stated in figure legends, each data point is the mean (±SD) of three tissues, with each, where possible, from a separate shipment of Epiderm™ models, thus representing three biological replicates in cases where n = 3.
Results
Using three clastogens with different mechanisms of action (MMC, MMS and H2O2), for which there is a wealth of in vitro micronucleus data available, we evaluated the practicality of the RSMN assay as an advancement in traditional cell culture techniques for modelling genotoxicity and constructing dose-responses. A non-genotoxic carcinogen, methyl carbamate, was also included to validate the specificity of the assay and use of the Metafer Slide Scanning Platform. Dose ranges were selected using preliminary dose-finding studies with escalating doses applied until 50% toxicity (TD50) was reached, based on binucleate frequency values.
Morphology of Epiderm™ models
Sectioning and visualisation of these models was simple, effective and could prove useful in examining the absorption kinetics through skin by similar approaches. We established the morphological changes over time of untreated tissues and those treated with acetone, the recommended solvent, and water, our preferred solvent (Figure 1). No discernable differences were observed between the treatments but, crucially, water gave much lower binucleate frequencies than untreated and acetone-treated tissues (data not shown). Therefore, despite our initial reservations, acetone appears to be the most applicable solvent.
From our experiences with the assay, we were able to observe how the tissues responded to various conditions. For example, delivery of the models was at 4°C overnight from Bratislava and the manufacturers state that tissues are stable for 6 days at this temperature. On one occasion, tissues were delayed by 24h but were without observable defects. Although the vital statistics are within the expected range for a working assay (1,14), several batches were compromised, presumably during transit, and had poor cell yield. Such tissues had a distinct pink coloration once the topical surface had been blotted dry of residual medium following unpacking. It seems likely that the observed pink colouration was due to a leak in the polymer at the bottom of each tissue support, leading to movement of media into the tissue. Remnants of dried medium remained on the topical surface, giving the appearance of a red ring around the perimeter of some tissues, which could not be removed by sterile gauze. However, this had no adverse effect on tissue behaviour. Incidentally, blotting the topical surface to remove condensation accumulated during transit was important for ensuring optimal development of the models. This step was omitted on one occasion and this appeared to reduce binucleate frequency.
Reproducibility
Low inter-batch variability (where a batch is defined as an individual plate of 24 tissues; each batch was usually shipped independently, unless two batches were ordered to arrive in one package) was generally observed in tissues processed in our laboratory, suggesting that the assay is reproducible and supporting previous findings (2). It is also worth noting that as the same donors are used for tissues cultured in both MatTek’s USA and Slovakia laboratories (S. Letasiová, MatTek, personal communication), direct comparisons between the two MatTek laboratories is a possibility. Historical solvent control data from our laboratory were concordant with levels of previous studies (1,2), with a micronucleus frequency of 0.05% (±0.05%, n = 26) (Figure 2). Historical binucleate frequency for the solvent control was 52.9±7.75%, which also corresponded with previous studies and was within the expected range (2,17).
MMC positive control data were also reproducible (0.8±0.64%) (n = 18) (Figure 3). Although caution is urged with regard to large inter-batch variation received over an 18-week period, our positive control data remain significantly greater than solvent control (Figure 3). Previous inter-laboratory studies have demonstrated variation in micronucleus induction at 6 µg/ml MMC, with frequencies <0.7% reported which are still significantly greater than solvent control levels (2). Further, our historical positive control micronucleus frequency is also around 14× greater than the solvent control frequency, yet it is clear that the aforementioned overlap is an observation that would need addressing for regulatory acceptance. Interestingly, the historical positive control binucleate frequency of 44.2±9.04% is remarkably similar to that observed in three USA-based laboratories, which ranged from 40.9 to 47.1% (2). Overall cell yield was also within the ranges achieved in previous studies (2), according to trypan blue-based cell counting from early batches, which generally yielded between 180000 and 345000 cells.
LOGELs for topical MMS treatments in other laboratories ranged between 600 and 1000 µg/ml (1,2). Considering the inevitable, if slight, variation between laboratories performing the assay, and distributors and donors of the models (2), these figures are within around 3× of our LOGEL for topical MMS of 1750 µg/ml, a relatively minor variation. As mentioned previously, variability was also observed for binucleate frequency at high doses of H2O2, yet micronucleus frequency remained at background levels.
The mononucleate assay is less sensitive than the binucleate assay for detection of micronuclei
To validate the influence of cytokinesis block for the RSMN assay’s sub-acute dosing approach (two separate doses of cytoB and test chemical, rather than a single, acute dose, as per 2D), the mononucleate assay was performed (Figure 2). Micronucleus frequency for the binucleate assay in 3D tissues was greater than for the mononucleate assay for the three test articles investigated: there was a 2.9-fold difference for acetone, 3.4-fold for 6 µg/ml MMC positive control and 2.3-fold for MMS treatment. However, only MMC gave a statistically significant difference between mononucleate and binucleate frequency.
Applicability of the Metafer for detecting micronucleus events in keratinocytes
Tissues were treated with a solvent control and 6 µg/ml MMC per day for 2 days to elicit a positive response. From the same tissue, slides were prepared and stained for manual and automated scoring methods allowing for a direct comparison (Figure 3). Although Metafer produced a greater micronucleus frequency than manual for MMC, a strong positive correlation (r = 0.921) was observed between the two methodologies, indicating their congruency. There was no significant difference between the two methodologies for the solvent control (P < 0.05), and although Metafer was again slightly greater, producing 0.07% compared to 0% for manual, the Metafer value fell within the expected range (14). Due to the advantages of automation over manual methods, automated scoring was preferred and hereafter utilised in the detection of micronuclei. We also found that counting samples of cells upon harvesting with trypan blue, as recommended by MatTek In Vitro Life Science Laboratories, did not give reproducible scores for toxicity. Instead, binucleate frequency was used as a toxicity measure, as mentioned previously.
MMC produced a LOGEL for micronucleus induction when applied topically
In this assay, 48 µg/ml MMC (a total of 1.5 µg/cm2 over 48h) was found to be the TD50. The TD50 achieved was greater than that reported in the literature, possibly due to differences in miscibility of MMC, although the reason for this is unknown and warrants further investigation (2). The dose–response in Figure 4 was at low doses of MMC, at least 4-fold lower than the TD50 to establish low-dose trends. Doses up to 3.6 µg/ml MMC did not cause a significant increase in micronucleus frequency compared to the solvent control. The lowest alpha value was P = 0.685 at 1.2 µg/ml MMC. The lowest dose causing significant micronucleus induction over the solvent control was 4.8 µg/ml for topical application of MMC (P = 0.03) (Figure 4A), thus representing the LOGEL. However, subsequent broken stick dose–response modelling (16) (Figure 4B), used to define a threshold doses in non-linear dose responses, found no evidence of a threshold and therefore, the null hypothesis of a linear dose–response cannot be rejected (P > 0.05). The model may, however, be skewed by the variation at higher doses.
H2O2 and methyl carbamate did not cause an increase in micronucleus frequency when applied topically
Topical administrations of doses of H2O2 exceeding 35mg/ml (>1.1 µg/cm2) caused substantial blistering of the stratum corneum but failed to elicit a positive micronucleus response (Figure 5A). It is interesting to note that other parameters may play a role in determining ‘maximum tolerated doses’ other than the TD50 in 3D models. The highest dose of H2O2 tested for micronucleus induction (50mg/ml) caused a 45% reduction in binucleate frequency compared to control without an increase in micronuclei events. However, there was considerable variation between tissues where binucleate frequency, following treatment with 60mg/ml, which ranged from 45 to 12.5%, thereby giving misleading TD50 values, which could impact on hazard identification by these models (3).
In other studies performed within our laboratory, Metafer has consistently given slightly higher micronucleus frequencies than manual scoring. We questioned the specificity of the Metafer and whether this slight over-exaggeration would lead to false positives. Therefore, methyl carbamate, a non-genotoxic carcinogen, was used to validate the specificity of the assay and scoring approach. Methyl carbamate elicited a negative response for micronucleus induction, with no LOGEL (P > 0.05) (Figure 5B). Using a non-genotoxin suggests that there is concordance between manual and Metafer scoring, and that the Metafer is not likely to over-predict micronucleus frequency. The doses used here were 100-fold greater than those previously used in vitro to conclude that methyl carbamate is non-genotoxic (18). Despite this, toxicity was not observed at these higher doses for methyl carbamate in EpiDerm™ models. Higher doses (up to 800 µg/ml, data not shown) resulted in a reduction of binucleate frequency to 39.1%, without an increase in micronucleus frequency (n = 2). As TD50 was not observed, the dose range utilised was perhaps not optimal.
MMS induced LOGELs for both topical and medium dosing
We explored topical and medium application of the well-characterised methylating agent and clastogen, MMS. Initially, the selected topical dose range was based upon previous studies where increases in micronucleus frequency above solvent control levels were obtained (1,2). When these were found to give negative results in our laboratory, higher doses were tested until binucleate frequency decreased to <50% of control tissues. Topical application with MMS produced a LOGEL at 1750 µg/ml (54.69 µg/cm2) (Figure 6A). Addition of MMS directly into the medium produced a LOGEL of 20 µg/ml (Figure 6C). Whereas broken stick modelling suggests a threshold dose–response for topical application (P = 0.047) (Figure 6B), the medium dose–response is, interestingly, linear (P = 1) (Figure 6D).
The EpiDerm™ models express MPG mRNA
To assess whether 3D tissues express DNA repair genes relevant to the methylating agent used in this study, expression of the glycosylase MPG was measured in RNA extracted from 3D models. In addition, to examine dose-dependent differences in DNA repair enzyme expression following topical treatment of the EpiDerm™ models with MMS, reverse transcription–PCR was performed and visualised using DNA PAGE for MPG. Following treatment, no notable dose-dependent differences were observed for MPG expression (Figure 7). Although not quantitative, levels appeared consistent throughout samples, supporting expression of this DNA repair enzyme in the EpiDerm™ models. Inclusion of a sample of RNA from human lymphoblastoid cell line TK6 for comparison (Lane 10) suggests slightly higher expression of MPG in the EpiDerm™ tissues compared to TK6 cells.
Discussion
This study further validates the RSMN assay with the EpiDerm™ 3D human skin model and supports its use in the in vitro genotoxicity test battery, particularly when assessing cosmetic ingredients. For the first time, we have linked these 3D skin models with automated micronucleus detection using an image analysis system (Metafer). We have used this approach to generate robust dose responses for four chemicals, which have allowed initial comparisons with genotoxicity in traditional 2D cell culture systems.
Success of inter-laboratory transfer of RSMN methodology
Initial RSMN assays were performed as detailed by Mun et al. (1). Accordingly, 3 µg/ml MMC was used to cause a positive response, where micronucleus frequency exceeded 1%. However, in our hands, 3 µg/ml failed to produce such an effect (Figure 3) and 6 µg/ml MMC was used instead. Similarly, a higher dose of MMS was needed (1750 µg/ml) to produce a statistically significant increase in micronucleus frequency over the solvent control compared to previous laboratories’ findings (600 µg/ml) (1), although this was a relatively minor variation, as mentioned previously. The reason for the observed variation is unknown, but this would need to be addressed for standardisation of the RSMN assay.
Furthermore, differences between dose responses for the same chemicals in different laboratories may be due to technical (i.e. chemical preparation and/or dosing techniques), Metafer-based, or donor-related differences within our approach compared to that of previous studies. Such inevitable variations could be due to chemical preparation and dosing technique, for example. Inter-batch variation within a laboratory, as mentioned previously, may also play a role. The lower background micronucleus frequency of EpiDerm™ models compared to cell lines is possibly due to greater genetic stability of primary keratinocytes within the tissues, compared to genetically transformed cell lines, where background micronucleus frequency is potentially more than 10-fold greater (9). This further supports the use of such approaches for providing a more representative model of human exposure in vitro than current approaches.
Automation of micronucleus detection in the RSMN assay
We have demonstrated the Metafer’s potential for automating micronucleus detection in the RSMN assay. We have also found that the assay’s shorter cell fixation protocol is compatible with Metafer analysis and, therefore, with further validation, this protocol might be adapted as a standard harvest protocol for Metafer, reducing time and materials required compared to the current harvest procedure for cell culture experiments. Furthermore, a negative result for methyl carbamate, a non-genotoxic carcinogen, confirmed that Metafer is unlikely to elicit false-positive micronucleus frequency results for non-genotoxic chemicals, despite showing exaggerated micronuclei frequencies compared to manual methods for genotoxins. Given this, we are confident that Metafer analysis is specific for positive genotoxins.
To further validate the use of Metafer in micronucleus quantitation in the RSMN assay, three coded chemicals, MMC, N-ethyl-N-nitrosourea and etoposide, were scored using our Metafer System and results compared to manual scoring performed at P&G Laboratories (USA) (Figure 8). In all cases, methodologies showed remarkable similarity in dose-responses. Importantly, this comparison demonstrated that, for the majority, automated scoring correctly distinguished positive results from concurrent controls analogous to manual scoring. Additionally, the inter-study differences we have observed for MMC and MMS cannot be attributed to the scoring methodology. Although Metafer appeared to slightly under-predict micronucleus frequency in general, the only statistically significant difference between the two methodologies occurred at 10 µg/ml etoposide. Here, manual scoring showed this to be significantly different to the solvent control. Upon investigation, it appeared that the magnification used for scanning slides might influence the number of both binucleates and micronuclei detected by the Metafer. For example, use of the ×20 objective appears to enable greater visual clarity and could, therefore, give results closer to manual micronucleus detection than lower magnifications, such as ×10. This may partly be due to the relatively small nuclear diameter of EpiDerm™-derived cells, when compared with that of the lymphoblastoid cell lines that our Metafer system is optimised to detect. Further, P&G uses ×400 magnification to identify micronuclei, while ×100 is used for by-eye confirmation for Metafer; this difference may partly explain the difference observed between Metafer and manual in this case. It would also be possible to, in future, experiment with a lower power objective, more commonly used in manual scoring, with Metafer for by-eye confirmation (e.g. ×60). An interesting observation resulting from this collaboration was that P&G’s 6 µg/ml MMC produced a micronucleus frequency of 4.4% following Metafer analysis (Figure 8), compared to 0.7% at Swansea. This indicates that further investigation may be required, perhaps including inter-laboratory validations. However, as mentioned previously, a highly significant difference was observed between historical solvent and positive control micronucleus frequencies.
Based on the preliminary investigations outlined in this study, it is recommended that further optimisation be completed prior to Metafer being incorporated into this assay routinely. However, these findings are encouraging and provide a solid starting point for combining objective micronucleus scoring with the RSMN assay, giving increased statistical power from analysis of a greater number of cells. Combining 3D skin models with automated micronucleus detection could, therefore, be a major step forward in the quest for animal replacements.
Correlation with 2D data
The parameters defining non-linearity used here serve as a comparison between 2D and 3D systems and not to define thresholds. The mechanisms of such thresholds are beyond the scope of this study, although differences in LOGELs between 2D and 3D maybe due to assay sensitivity, differential cellular dynamics (cell cycle time), repair capacities and checkpoint proficiencies, or different diffusion and reaction kinetics owing to the different microenvironments. Comparisons between LOGELs obtained in 2D cell culture, such as cells grown in suspension, to those of 3D EpiDerm™ models, may, however, be informative for evaluation of the RSMN assay. For MMS, it is apparent that 2D cell culture models are more susceptible to MMS than the 3D models used here (Figure 6). Around 7×, more chemical was required to elicit a LOGEL in 3D, for both topical and medium dosing, than 2D (Figure 9). Interestingly, approximately the same overall mass elicited a LOGEL in 2D (0.1 µg) and 3D topical (0.096 µg) for MMC (Table I). Whereas topical dosing involves concentrating the chemical over a small area, treatment within a 2D culture disperses chemical over a relatively large volume. This emphasises the difficulty of accurately extrapolating between 2D and 3D topical exposure, due to the contrasting kinetics of the two approaches. A more accurate comparison would be between 2D and 3D medium exposure, as in both cases, the chemical is diluted in medium.
Table I.
MMC | MMS | ||||
---|---|---|---|---|---|
2D | 3D (topical) | 2D | 3D (topical) | 3D (medium) | |
LOGEL (µg/ml) | 0.01 | 4.8 | 0.5 | 1750 | 20 |
Final concentration (µg/ml) | 0.01 | 9.6 | 0.5 | 3500 | 40 |
Total µg applied to system | 0.1 | 0.096 | 5 | 35 | 36 |
LOGEL for MMC in 2D represents that of L5178Y tk+/− cells (25). LOGEL for 2D was multiplied by 10 to account for 10ml culture, whereas 3D doubled to account for the two doses administered during the RSMN assay. Adjustments for total mass (µg) applied to system due to two 10 µl applications on the topical surface and 900 µl volume of medium.
Interestingly, a similar mass of MMS was required to elicit a LOGEL in both medium (36 µg) and topical (35 µg) treatments in EpiDerm™ (Table I). This perhaps suggests that EpiDerm™’s stratum corneum has limited barrier function, as observed previously (19). This also provides cause to question the suitability of the solvent, which may enhance the permeability of MMS through barrier disruption (20). However, this may also be explained by chemical on the topical surface being highly concentrated in a small area, yet in medium, it is relatively sparse. Therefore, it is necessary to acknowledge that these are extremely different dosing routes and that further investigation with other chemicals is required. With further study, it is possible that ‘sensitivity factors’ could be defined and applied for comparing 2D and 3D, if consistent levels of variation in LOGELs between the two systems are identified.
Our experience of using the models
H&E stained tissue sections (Figure 1) demonstrated that the stratum corneum thickened over the course of the assay, supporting the models as functional, dynamic representations of the human epidermis. Further, our observations when using the models demonstrated that specific characteristics, such as colour, are important indicators of cell yield and overall health of the models. As mentioned previously, maintaining a dry topical surface is crucial for ensuring that the models remain at their optimum. This became apparent when we questioned the suitability of using the recommended solvent, acetone, by applying a supposedly more biologically compatible alternative, water. When water alone was applied topically, there was a substantial reduction in the binucleate frequency, suggesting that the layer of water remaining on the topical surface prevented cell proliferation and impeded cellular gas exchange. Additionally, a positive dose of 6 µg/ml MMC in acetone was negative in water for micronucleus induction. Whether this is due to water inhibition or acetone potentiation is still unknown. Potential reactivity of acetone with the test article should be realized and may explain the negative result for H2O2 in Figure 5 (21). Referring to this, a positive result was expected given that H2O2 has been shown to cause strand breaks in the comet assay in HaCaT transformed keratinocytes (22). Additionally, micronucleus induction following treatment with H2O2 in human lymphoblastoid cell lines has previously been observed by our research group (10). Whether our negative result is an artefact of the RSMN assay or whether it demonstrates a true null effect in the micronucleus assay through either detoxification (11), efficient oxidative adduct repair or lack of exposure to the deeper epidermal layers is unknown. Indeed, clastogenic effects may be diminished by reaction of H2O2 with dead cellular matter prior to entry into the cells, and it is possible that chemicals derived from these reactions contributed to reduction in binucleate frequency. Whether there is a full complement of DNA repair and antioxidant capacities or sufficient barrier protection from the stratum corneum remains to be seen. In this instance, medium application of H2O2 may be informative.
Mononucleate assay
The mononucleate assay appeared to be less sensitive than the binucleate assay for detection of micronuclei. This may be due to the binucleate assay only considering cells that had divided since the addition of cytoB, whereas the mononucleate assay indiscriminately considers all intact cells (23). Consequently, cells that are senescent, in cell cycle arrest, or pre-apoptotic during the assay, would not have undergone nuclear division since, and indeed due to, chemical exposure (24). Such cells will not contain micronuclei, regardless of the presence of sufficient chromosomal damage (24). This may also occur when the culture conditions do not allow an optimal number of dividing cells for analysis (24). As a result, this is likely to lead to underestimation of micronucleus frequency, generating false-negative results (23). Another disadvantage of the mononucleate assay was that binucleate frequencies could not be obtained for these tissues, due to no cytoB to inhibit cytokinesis.
Gene expression
Evidence of the mRNA of the DNA repair enzyme, MPG, in tissues of different treatments, indicates that these models are likely to be DNA repair competent. This develops the findings of previous studies of mRNA expression in EpiDerm™, which confirmed comparable expression of xenobiotic metabolising enzymes between human skin and EpiDerm™ (5). However, as presence of mRNA is not necessarily indicative of protein or DNA repair activity, further investigation is required. MPG expression in EpiDerm™ appears slightly greater than for human lymphoblastoid cell line TK6 (Figure 7, Lane 10), suggesting possibly only subtle differences in repair capacity of cell lines and 3D models. Studies of gene expression in EpiDerm™ are particularly important for comparisons with normal human skin, as well as comparisons to existing in vivo test models. It was also possible to quantify protein from the models by western blotting of total protein extracts (data not shown).
Conclusions
We have made advancement in the RSMN assay through inclusion of an automated scoring procedure. Although our data are preliminary, and further validation is required to confirm that Metafer correlates reproducibly with manual scoring, it is clear that there is potential for incorporating the Metafer into this assay. Further optimisation of the ×20 objective in slide scanning by Metafer would be beneficial if the Metafer’s potential in this assay is to be maximised. Combining the assay with the major statistical and practical benefits of Metafer may play a significant role in the reduction of unnecessary animal tests in toxicology. We have also demonstrated that the assay is reproducible and possibly less susceptible to producing misleading positives than existing in vitro tests, perhaps providing an alternative follow-up for positives generated by standard in vitro genotoxicity assays.
Supplementary data
Supplementary Figure 1 is available at Mutagenesis Online.
Funding
This work was supported by the National Centre for the Replacement, Refinement and Reduction of Animals in Research (NC3Rs; Jenkins.G.10-07-2009), the Medical Research Council (MRC; G1000821) and the Engineering and Physical Sciences Research Council (EPSRC; EP/H008683/1).
Supplementary Material
Acknowledgements
We would like to thank Dr Rodger Curren at the Institute for In Vitro Sciences, MD, USA, for kindly providing training prior to introduction of the assay to our laboratory. Tissues in Figure 1 were sectioned by Samantha Spencer-Harty at the Department of Histopathology, Singleton Hospital, Swansea. The processing of tissues and manual scoring shown in Figure 8 were completed by Brenda Barnett of The Procter & Gamble Co., OH, USA. The UK Environmental Mutagen Society (UKEMS) is also gratefully acknowledged for their Technology Transfer and Training Bursary awarded to J.W.W.
Conflict of interest statement: None declared.
References
- 1. Mun G. C., Aardema M. J., Hu T., Barnett B., Kaluzhny Y., Klausner M., Karetsky V., Dahl E. L., Curren R. D. (2009). Further development of the EpiDerm 3D reconstructed human skin micronucleus (RSMN) assay. Mutat. Res., 673, 92–99 [DOI] [PubMed] [Google Scholar]
- 2. Hu T., Kaluzhny Y., Mun G. C., Barnett B., Karetsky V., Wilt N., Klausner M., Curren R. D., Aardema M. J. (2009). Intralaboratory and interlaboratory evaluation of the EpiDerm 3D human reconstructed skin micronucleus (RSMN) assay. Mutat. Res., 673, 100–108 [DOI] [PubMed] [Google Scholar]
- 3. Fowler P., Smith R., Smith K., Young J., Jeffrey L., Kirkland D., Pfuhler S., Carmichael P. (2012). Reduction of misleading (“false”) positive results in mammalian cell genotoxicity assays. II. Importance of accurate toxicity measurement. Mutat. Res., 747, 104–117 [DOI] [PubMed] [Google Scholar]
- 4. Kirsch-Volders M., Decordier I., Elhajouji A., Plas G., Aardema M. J., Fenech M. (2011). In vitro genotoxicity testing using the micronucleus assay in cell lines, human lymphocytes and 3D human skin models. Mutagenesis, 26, 177–184 [DOI] [PubMed] [Google Scholar]
- 5. Hu T., Khambatta Z. S., Hayden P. J., et al. (2010). Xenobiotic metabolism gene expression in the EpiDerm™ in vitro 3D human epidermis model compared to human skin. Toxicol. In Vitro, 24, 1450–1463 [DOI] [PubMed] [Google Scholar]
- 6. Aardema M. J., Barnett B. B., Mun G. C., Dahl E. L., Curren R. D., Hewitt N. J., Pfuhler S. (2013). Evaluation of chemicals requiring metabolic activation in the EpiDerm™ 3D human reconstructed skin micronucleus (RSMN) assay. Mutat. Res., 750, 40–49 [DOI] [PubMed] [Google Scholar]
- 7. Hu T., Bailey R. E., Morrall S. W., Aardema M. J., Stanley L. A., Skare J. A. (2009). Dermal penetration and metabolism of p-aminophenol and p-phenylenediamine: application of the EpiDerm human reconstructed epidermis model. Toxicol. Lett., 188, 119–129 [DOI] [PubMed] [Google Scholar]
- 8. Jenkins G. J., Doak S. H., Johnson G. E., Quick E., Waters E. M., Parry J. M. (2005). Do dose response thresholds exist for genotoxic alkylating agents? Mutagenesis, 20, 389–398 [DOI] [PubMed] [Google Scholar]
- 9. Doak S. H., Jenkins G. J., Johnson G. E., Quick E., Parry E. M., Parry J. M. (2007). Mechanistic influences for mutation induction curves after exposure to DNA-reactive carcinogens. Cancer Res., 67, 3904–3911 [DOI] [PubMed] [Google Scholar]
- 10. Thomas A. D., Jenkins G. J., Kaina B., Bodger O. G., Tomaszowski K. H., Lewis P. D., Doak S. H., Johnson G. E. (2013). Influence of DNA repair on nonlinear dose-responses for mutation. Toxicol. Sci., 132, 87–95 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11. Seager A. L., Shah U. K., Mikhail J. M., et al. (2012). Pro-oxidant induced DNA damage in human lymphoblastoid cells: homeostatic mechanisms of genotoxic tolerance. Toxicol. Sci., 128, 387–397 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12. Rossnerova A., Spatova M., Schunck C., Sram R. J. (2011). Automated scoring of lymphocyte micronuclei by the MetaSystems Metafer image cytometry system and its application in studies of human mutagen sensitivity and biodosimetry of genotoxin exposure. Mutagenesis, 26, 169–175 [DOI] [PubMed] [Google Scholar]
- 13. Seager A. L., Shah U. K., Brüsehafer K., Wills J. W., Manshian B., Chapman K. E., Thomas A. D., Scott A., Doherty A., Doak S. H., Johnson G. E., Jenkins G. J. S. (2014) Recommendations, evaluation and validation of a semi-automated, fluorescent-based scoring protocol for micronucleus testing in human cells. Mutagenesis, Accompanying paper. [DOI] [PubMed]
- 14. Curren R. D., Mun G. C., Gibson D. P., Aardema M. J. (2006). Development of a method for assessing micronucleus induction in a 3D human skin model (EpiDerm). Mutat. Res., 607, 192–204 [DOI] [PubMed] [Google Scholar]
- 15. Fenech M., Chang W. P., Kirsch-Volders M., et al. (2003). HUMN project: detailed description of the scoring criteria for the cytokinesis-block micronucleus assay using isolated human lymphocyte cultures. Mutat. Res., 534, 65–75 [DOI] [PubMed] [Google Scholar]
- 16. Lutz W. K., Lutz R. W. (2009). Statistical model to estimate a threshold dose and its confidence limits for the analysis of sublinear dose-response relationships, exemplified for mutagenicity data. Mutat. Res., 678, 118–122 [DOI] [PubMed] [Google Scholar]
- 17. Dahl E. L., Curren R., Barnett B. C., et al. (2011). The reconstructed skin micronucleus assay (RSMN) in EpiDerm™: detailed protocol and harmonized scoring atlas. Mutat. Res., 720, 42–52 [DOI] [PubMed] [Google Scholar]
- 18. Wang T. C., Chiou C. M., Chang Y. L. (1998). Genetic toxicity of N-methylcarbamate insecticides and their N-nitroso derivatives. Mutagenesis, 13, 405–408 [DOI] [PubMed] [Google Scholar]
- 19. Yuki K., Ikeda N., Nishiyama N., Kasamatsu T. (2013. ) The reconstructed skin micronucleus assay in EpiDerm™: reduction of false-positive results – a mechanistic study with epigallocatechin gallate. Mutat. Res., 757, 148–157 [DOI] [PubMed] [Google Scholar]
- 20. Tsai J. C., Sheu H. M., Hung P. L., Cheng C. L. (2001). Effect of barrier disruption by acetone treatment on the permeability of compounds with various lipophilicities: implications for the permeability of compromised skin. J. Pharm. Sci., 90, 1242–1254 [DOI] [PubMed] [Google Scholar]
- 21. Jensen L., Mortensen P. M., Trane R., Harris P., Berg R. W. (2009). Reaction kinetics of acetone peroxide formation and structure investigations using Raman spectroscopy and X-ray diffraction. Appl. Spectrosc., 63, 92–97 [DOI] [PubMed] [Google Scholar]
- 22. Petersen A. B., Gniadecki R., Vicanova J., Thorn T., Wulf H. C. (2000). Hydrogen peroxide is responsible for UVA-induced DNA damage measured by alkaline comet assay in HaCaT keratinocytes. J. Photochem. Photobiol. B., 59, 123–131 [DOI] [PubMed] [Google Scholar]
- 23. Fenech M. (2000). A mathematical model of the in vitro micronucleus assay predicts false negative results if micronuclei are not specifically scored in binucleated cells or in cells that have completed one nuclear division. Mutagenesis, 15, 329–336 [DOI] [PubMed] [Google Scholar]
- 24. Fenech M. (2000). The in vitro micronucleus technique. Mutat. Res., 455, 81–95 [DOI] [PubMed] [Google Scholar]
- 25. Kirsch-Volders M., Sofuni T., Aardema M. J., et al. (2003). Report from the in vitro micronucleus assay working group. Mutat. Res., 540, 153–163 [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.