Accurate Image Analysis of the Retina Using Hessian Matrix and Binarisation of Thresholded Entropy with Application of Texture Mapping

Xiaoxia Yin 1,*, Brian W-H Ng 2, Jing He 1, Yanchun Zhang 1, Derek Abbott 2
Editor: Alfred S Lewin3
PMCID: PMC4004557  PMID: 24781033

Abstract

In this paper, we demonstrate a comprehensive method for segmenting the retinal vasculature in camera images of the fundus. This is of interest in the area of diagnostics for eye diseases that affect the blood vessels in the eye. In a departure from other state-of-the-art methods, vessels are first pre-grouped together with graph partitioning, using a spectral clustering technique based on morphological features. Local curvature is estimated over the whole image using eigenvalues of Hessian matrix in order to enhance the vessels, which appear as ridges in images of the retina. The result is combined with a binarized image, obtained using a threshold that maximizes entropy, to extract the retinal vessels from the background. Speckle type noise is reduced by applying a connectivity constraint on the extracted curvature based enhanced image. This constraint is varied over the image according to each region's predominant blood vessel size. The resultant image exhibits the central light reflex of retinal arteries and veins, which prevents the segmentation of whole vessels. To address this, the earlier entropy-based binarization technique is repeated on the original image, but crucially, with a different threshold to incorporate the central reflex vessels. The final segmentation is achieved by combining the segmented vessels with and without central light reflex. We carry out our approach on DRIVE and REVIEW, two publicly available collections of retinal images for research purposes. The obtained results are compared with state-of-the-art methods in the literature using metrics such as sensitivity (true positive rate), selectivity (false positive rate) and accuracy rates for the DRIVE images and measured vessel widths for the REVIEW images. Our approach out-performs the methods in the literature.

Introduction

Retinal vascular disorders refer to a range of eye diseases that affect the blood vessels in the eye. Assessment of vascular characteristics plays an important role in various medical diagnoses, such as diabetes [1], [2], hypertension [3] and arteriosclerosis [4]. Retinal vessel segmentation algorithms are a fundamental component of computer aided retinal disease screening systems. Manual delineation of retinal blood vessels is a long and tedious task and requires extensive training and skill [5]. This motivates accurate machine-based quantification of retinal vessels that assist ophthalmologists in increasing the accuracy of their screening processes, allowing fewer highly trained individuals to carry out the screening processes, which may be of clinical benefit [6].

Fundus photography involves taking digital images of the back of the eye, such as the retina, optic disc, and macula [7]. Fundus photography is used clinically to diagnose and monitor progression of a disease. It is needed to obtain measurements of vessel width, colour, reflectivity, etc. State-of-the-art algorithms can be divided into a few main categories that deal with retinal vessel segmentation from fundus photographs, and recent review papers have already discussed these in some detail [8], [9]. We include only a brief summary of these reviews to sufficiently set the context for our work.

Classifier based approaches are perhaps the simplest. Two distinct categories of pattern classification techniques for vessel segmentation are supervised (which requires training) [10] and unsupervised (which do not) [11]. Training a classifier uses datasets of manually labelled vessel images to allow the classifier to recognise retinal vessel regions from the background; such techniques have been employed by Nekovei and Ying [12], Staale et al. [5] and Soares et al. [13], among others. In contrast, unsupervised classifiers attempt to find, directly, inherent differences between blood vessels and the background in images of the retina; examples include fuzzy C-means clustering [14] and Bayesian classification [15]. The finding in [8] is that in general, supervised classification has improved performance over unsupervised schemes, although the performance is affected by issues such as non-uniform illumination.

Apart from classifier-based approaches, other main categories of techniques in the literature include: matched filtering, morphological processing, vessel tracing, multi-scale processing, and model-based approaches [8]. Matched filtering attempts to find correlation between a fundus photograph with templates of vessels, known as kernels. Examples are reported in [16][18]. Regions with high correlation are thus detected as blood vessel structures. Another method, which uses matched filtering, is based on a binarisation via local entropy that is applied by Villalobos-Castaldi et al. [19] for vessel segmentation. The binarization approach involves a matched filter for vessel enhancement with combination of the gray-level co-occurrence matrix to calculate a statistical feature in relation to local entropy. The statistical feature acts as a threshold value for segmentation of the vessel network. Morphological processing applies operations with pre-determined structuring elements, designed to capture certain shapes, to the image. To carry out vessel segmentation with morphological operations, the base assumption is that vessels are constructed as connected linear segments. Such approaches possess an improved reduction in noise within the segmentation result, but the main disadvantage lies in a lack of ability to fit complex vessel structures. Examples of this approach in the literature can be found in [20], [21]. Vessel tracking attempts to find the path that best matches the vessels in a given image, subject to pre-determined vessel profile models, by following vessel centre lines using local characteristics for guidance. Such approaches [22][24] lead to accurate vessel width calculation and can identify individual vessel segments that other methods struggle to find. Multi-scale approaches exploit the fact that vessel widths decrease as they extend away from the optical disk. Many of the multi-scale algorithms involve vessel enhancement filters, such as in [25][27]. Model based approaches construct explicit models for vessels, designed to capture various properties, such as a Laplacian cross profile in intensity across a vessel [28], robust selection of blood vessel models [29] and deformable models [30], [31], for just a selection.

Studies in the literature provide inspiration for our proposed framework. In particular, our approach uses Hessian matrix analysis for curvature evaluation, which delineates the texture features of retinal vessels accurately, in combination with binarization via thresholded entropy to achieve a basic segmentation of retinal vessels. Fine-tuning the segmentation is performed by a further application of morphological operations to prune and identify the vessel segments and remove noise pixels. A novel aspect of this work is the separation of post processing for vessels of different thicknesses, partitioned into two broad classes. This is accomplished using texture mapping with a spectral clustering approach [32], and it assists in increasing the accuracy of final segmentation.

This paper makes three contributions. First, image enhancement is a significant pre-processing step in this paper's algorithm for smoothing retinal images and enhancing the contrast between vessels and the background. It aims to remove noisy regions from the overall retinal image to enable accurate segmentation of retinal vessels. One way to increase the image contrast is to enhance the image ridges associated with the retinal vessels. However, in order to better enhance vessels of different widths, traditional approaches require construction of multi-scale matched filters at multiple orientations [33]. In contrast, this paper's approach uses eigenvalue analysis of the Hessian matrix to enhance ridges in the retinal images without changing the filter width. The texture analysis using features from local area estimates then allows areas with predominantly different vessel widths to be discriminated from each other.

Second, accurate segmentation of retinal vessels has the potential to improve the diagnosis of retinal disorders. To achieve accurate segmentation, our approach pre-groups vessels using a morphology based spectral clustering technique. This produces a simple colour map of the fundus images according to textural vasculature features instead of complex threshold processing for the evaluation of multi-scale images. Thereafter, the connectivity constraint is applied to the extracted vessels, with the constraints varied according to different texture regions: for regions where fine-grained noise in relation to small vessels are dominant, a smaller connectivity constraint is selected, and vice versa for regions that mainly consist of coarse-grained noise in relation to large vessels. The texture mapping operation also yields a partition of the pathological vessels from heathy ones, and allows to accurate removal of noise via morphological processing, aiming for accurate isolation of noise from vessels. The results in this paper show that the proposed algorithm outperforms other supervised and unsupervised segmentation methods in achieving high accuracy.

Third, one of the key goals of this paper is to achieve mostly automatic width measurement of blood vessels in retinal images from the segmented vessels. An important step in measuring retinal vessels is to extract centrelines and localise vessel edges from the segment image, by making use of the thinning morphology operation and calculating the number of pixels with overlap between the line perpendicular to each of the local vessel centrelines and the pixels from vessel segments. In this method, we introduce a 3×3 window to deal with each of the vessel branches, which is especially effective for vessel branches that cross. Using images from the REVIEW database [34], we show that our algorithm is capable of achieving a high level of accuracy and low measurement error, both for low and high resolution images. The algorithm described here automates of the analysis of retinal vessel widths, and is capable of finding widths at all points along the length of each vessel rather than at specific points of interest.

Materials and Methods

The method presented in this paper is based on unsupervised classification by finding inherent patterns of blood vessels in retinal images that can then be used to determine whether a particular pixel belongs to a vessel or not. The method uses region-based properties of retinal blood vessels for segmentation via using colour coded mapping to partition eigenvalue related enhancement of retinal images. A flow chart for image segmentation process is shown in Fig. 1; subsequent discussions of the details of our method will refer to steps illustrated in this figure.

Figure 1. Illustration of the flow chart regarding the proposed retinal image segmentation algorithm.

Figure 1

We number each of the steps in this figure from 1 to 5, which are associated with texture mapping, enhanced image extraction, partition, entropy binarisation for vessels with central light reflex (second entropy), and validation, respectively.

Image sources

The standard paradigm for validating medical image processing algorithms is to compare their outputs with a ground truth, or gold standard, generated by one or more human experts. To enable comparative assessment, we use image and associated manual segmentations from two public data sets available on the web, DRIVE [5] and REVIEW [35]. Both DRIVE and REVIEW databases include ground truth segmentations for their images.

The DRIVE database contains 40 colour images of the retina, Inline graphic pixels per colour channel from three colour channels, represented in LZW compressed TIFF format. These images are originally captured from a Canon CR5 non-mydriatic 3 charge-coupled device (CCD) camera with a Inline graphic field of view (FOV), and are initially saved in JPEG-format. In addition to the colour images, the database includes binary images with results of manual segmentation. The 40 images are divided into a training set and a test set by the authors of the database. The results of the two manual segmentations are available for all the images of this test. The twenty colour images from a test set are to be analysed. One set of gold standard binary images and one set of manually segmented binary images showing blood vessels are made available. To validate blood vessel width measurements, we use the REVIEW database, because this database also offers gold standard vessel measurements. These images are of higher resolution than the DRIVE images, ranging in size from Inline graphic to Inline graphic pixels. In all cases, the colour images are converted to grayscale by extracting the green channel information, because the green channel exhibits the best contrast for vessel detection [36]. To improve the local contrast of the retinal image, a preprocessing step, using morphological top-hat transform, is adopted from [37].

Fig. 2 shows the green channel image that is selected from the original image named 02_test from the DRIVE database. The image is clear and shows no signs of any pathological tissues.

Figure 2. The green channel only image of a fundus photograph.

Figure 2

The image is 02_test from DRIVE database.

Morphology Based Spectral Clustering

Photography of the eye fundus typically gives rise to complications such as inadequate contrast, lighting variations, influence of noise and anatomic variability affecting both the retinal background texture and the blood vessel structures [9]. Spectral clustering methods are promising approaches to perceptual retinal vessel segmentation that take into account global image properties as well as local spatial relationships. The method in [20], [38] integrates complex wavelet transforms with spectral clustering for a measure of spatial variation in texture via the morphological watershed algorithm [39]. It consists of four major stages. First, a dual-tree complex wavelet transform in the decimated domain is carried out to produce a set of image subbands. Next, a median filter is used to smooth the subband coefficients before the application of the gradient operator. The filtering operation is separable, scale- and orientation-adaptive, which produces nonlinear, edge-preserving smoothing and removes artificial noise from retinal images. The watershed algorithm, using image gradients, is then applied to the filtered image to produce an over segmented image. In our case, the implementation of the watershed algorithm [39] relies on the morphological H-minima transform, which controls over-segmentation. In the fourth stage, an image region similarity graph (RSG) is constructed from the over-segmented image. This is an undirected weighted graph where the set of nodes correspond to the atomic region (consisting of a set of connected pixels). For each pair of regions, the set of links represents relationships and the link weights represent similarity measures between the regions. Finally, we apply the spectral clustering technique to approximately solve this graph partitioning problem. This technique finds a partition of the graph such that the edges between different groups have a very low weight (which means that points in different clusters are dissimilar to each other) and the edges within a group have high weight (which means that points within the same cluster are similar to each other) [32].

In the context of this paper, spectral clustering groups together those regions in the RSG that have come from the same perceptual region, as illustrated in Fig. 3(A). This step produces the colour coded mapping contained in outline box 1 in Fig. 1. The texture features are grouped together according to a region's predominant blood vessel size, as demonstrated in Fig. 3(B). We then merge all the small regions (Fig. 3(A)) into two large regions (Fig. 3(B)) according to the local texture, i.e. fine-grained noise and coarse-grained noise. The detail regarding the texture will be discussed later in this manuscript. We manually adjust the threshold according to the connection limitation with application of morphology close operations. After application of different value of selected threshold to connection limitation, it is expected that the connection limitation with smaller threshold allows us to keep the small vessels as much as possible and filter out most fine-grained noise from background; for the connection limitation with larger threshold, it is expected to filter out most coarse-grained noise and obtain larger vessel branchings as clear as possible. An threshold is selected randomly and then we adjust it to see if there shows obvious change in texture of noise. If it exists, the spectral cluster can be used to regroup these small clusters.

Figure 3. Illustration of the texture-based partitioning of fundus photograph.

Figure 3

(A) Colour-coded mapping of the vessel texture, with the original image named 02_test from DRIVE database. (B) Colour-coded mapping of the two partitions of vessel texture: one is dominated by small blood vessels (labeled by blue colour) and the other is mainly controlled by large blood vessels (labeled by red colour).

Eigenvalue Analysis of Hessian Matrix

The vessel enhancement technique used in this paper is an eigenvalue analysis of the image Hessian matrix at a single scale, and is adapted from the multiscale version of Frangi el al. [25]. The fundus photograph is once again pre-processed using the top-hat transformation to produce the image Inline graphic. The local behaviour of the pre-processed image Inline graphic can be determined from its second order Taylor's series expansion in the neighbourhood of a point Inline graphic. The idea behind eigenvalue analysis of the Hessian Inline graphic is to extract the principal directions in which the local second order structure of the image can be decomposed [25]. In this case, the direction of smallest curvature along the vessel can be computed directly. This is achieved by finding the eigenvectors corresponding to the smallest eigenvalues. Fig. 4 shows the enhancement via eigenvalue analysis.

Figure 4. Illustration of a curvature based enhancement of the image of the retina via the eigenvalue analysis of Hessian matrix.

Figure 4

The image used is 02_test from the DRIVE database.

Maximum Entropy Binarisation

When a grayscale image is binarised, a threshold value must be specified. In our approach, the optimum threshold value is determined as the pixel intensity from the histogram of the image that exhibits the maximum entropy over the entire image. To represent spatial structural information of an image, a co-occurrence matrix is generated from the pre-processed image. It is a mapping of the pixel to pixel greyscale transitions (i.e. the gray level Inline graphic follows the gray level Inline graphic) in the image between the neighbouring pixel to the right and below each pixel in the image. The co-occurrence matrix of the pre-processed image Inline graphic (element wise), satisfying with the equation Inline graphic, is a two dimensional matrix of size Inline graphic, where the elements Inline graphic are defined as:

graphic file with name pone.0095943.e015.jpg (1)

where Inline graphic, if

graphic file with name pone.0095943.e017.jpg (2)

and otherwise, Inline graphic.

The probability of co-occurrence satisfies the equation, Inline graphic. A threshold Inline graphic that divides an image into two classes, background and object, also divide the co-occurrence matrix into four regions representing within object (Inline graphic), within background (Inline graphic), object to background (Inline graphic), and background to object class transitions (Inline graphic). Inline graphic is the maximum intensity value of the image to be analysed. The second-order entropy of the object (Inline graphic) and background (Inline graphic) are defined as:

graphic file with name pone.0095943.e028.jpg (3)
graphic file with name pone.0095943.e029.jpg (4)

Both Inline graphic and Inline graphic are functions of Inline graphic. By summing up the local transition entropies, the total second-order local entropy of the object and the background is given by

graphic file with name pone.0095943.e033.jpg (5)

Finally, the optimal threshold Inline graphic corresponding to the maximum of entropies Inline graphic over Inline graphic gives the optimal threshold for value [40]

graphic file with name pone.0095943.e037.jpg (6)

The final segmented binary mask of the vessel image is obtained by thresholding the pre-processed image Inline graphic with the optimal threshold Inline graphic:

graphic file with name pone.0095943.e040.jpg (7)

In order to obtain the initial mask of retinal vessels, we select a smaller magnitude of the threshold at vessel pixels near the vessel edges. Finally, we multiply the eigenvalue based enhanced image (after threshold) shown in Fig. 4 with the entropy based mask shown in Fig. 5(A). The resultant image is shown in Fig. 5(B). The method performs well in extracting the enhanced retinal vessels from the background with significantly reduced noise compared to other unsupervised mask or segmentation techniques.

Figure 5. Multiplication of images with the original image named 02_test from the DRIVE database.

Figure 5

(A) Illustration of the resultant mask used for extraction of the enhanced retinal vessels via entropy based binarisation. (B) A global thresholded image after combining (A) and Fig. 4.

Combining multiple segmentations to handle non-uniform illumination

This subsection addresses accurate segmentation techniques when combining the applications of several classical image processing algorithms mentioned above. Segmentations using a curvature based method (Eigenvalue analysis) show obvious signs of central light reflex. According to Spencer [41], the normal light reflex of the retinal vasculature is formed by reflection from the interface between the blood column and vessel wall, and thicker vessel walls cause the light reflex to be more diffuse and have lower intensity [42], [43]. In order to eliminate the effect of the central light reflex, we repeat the binarisation procedure on the top-hat preprocessed images, but with a larger threshold at vessel pixels near the related centreline of the retina vessels affected by the central light reflex. We manually select the thresholds and calculate the ideal segments of the central light reflex vessels. The final segmentation is the superposition of the segmentation from the extracted enhanced image, as shown in Fig. 5(B) and binarisation via entropy shown Fig. 6 (A), where the effect of the central light reflex, indicated by green arrows in Fig. 5(B), has been removed in the resultant image, as shown in Fig. 6 (B). We name this the dual-threshold entropy approach, to position it in the overall taxonomy of retina vessel segmentation methods, e.g. [8].

Figure 6. Outputs of interim processing steps.

Figure 6

(A) Illustration of binarisation with threshold selected to maximise entropy. (B) Illustration of the final segmentation, where the effect of central light reflex, indicated by green arrows in Fig. 5(B) has been removed in the resultant image.

To achieve clear segmentation of blood vessels in the images of the retina, we conduct simple morphology post-processing, i.e. morphological connectivity constraint operations on the extracted curvature based enhanced images. The connectivity constraint is varied according to different background texture of noise that dominates the image. The fine-grained noise texture (small contiguous bright region) determines small connectivity constraint, and vice versa for coarse-grained noise texture (relatively large contiguous bright region). The morphological spectral clustering is applied for the identification of textural regions. This is to consider the fact that texture appearance is changing with image recording parameters, for instance, illumination variation and direction of view, a problem common to any real surface. The extracted segmentation of texture works like windowing an image, which determines window size, position and shape with different texture appearance, different intensity distribution associated with different texture of background noise [44]. Regarding non-uniformed illumination of a retinal image, it is normally partitioned into two regions obviously according to the variation of illumination with change of vessel size. For instance, the extracted enhanced image illustrated in Fig. 7(A), consists of two regions: for regions where fine-grained noise (in relation to small retinal vessels) are dominant, shown in Fig. 7(B), it is reasonable to select the smaller connectivity constraint than the regions that consist of coarse-grained noise related to large vessels, shown in Fig. 7(C). The vessel segments corresponding to different background textures are linearly combined to produce the whole segmentation for the curvature based enhanced image. A similar method is used for a retinal image with pathological tissue, which will be differentiated into two parts with and without the pathology. The criteria to merge these segments into two are as follows. If the illumination is non-uniform, the segment with noise can be divided into two parts: (i) a segment with fine-grained noise texture and (ii) a segment with coarse-grained noise texture. The texture of noise is associated with the size of much smaller contiguous bright regions from the background after segmentation, which is different from retinal vessels that contain larger contiguous regions of bright pixels. The two portions in relation to two different textures of noise lead to two different segments. For pathological tissue, we consider the texture segments that contain the pathological tissue. Therefore we locate two groups of segments: (i) the group of segments containing pathological tissues and (ii) the group of segments containing healthy tissue. This is illustrated in the subsection on qualitative segmentation results.

Figure 7. Overview of the main steps taken by our algorithm when processing a fundus image.

Figure 7

(A) Illustration of globally thresholded image after multiplication between Fig. 4 and Fig. 5(A). (B) and (C) Illustration of two partitions of segmentation of (A) according to color coded mapping in Fig. 3(B). (D) Illustration of good overlapping (blue) between the resultant segment (yellow) and gold standard segment (green).

In order to achieve accurate segmentation of the retinal images, there are nine parameters produced in the segmentation procedure that need be adjusted manually. Actually, according to the resultant segmentation, it is found that such adjustments are simple and slightly changed among each retinal image. For reproducibility, these parameters are illustrated in the discussion section.

Width Measurement

We propose a vessel width measurement method to identify a pair of edge points representing the width of a vessel at a specific center point. The first step is to apply a morphological thinning algorithm [11] on the segmentation to locate the centreline; thinning iteratively removes exterior pixels from the detected vessels, finally resulting in a new binary image containing connected line segmentation of “on” pixels running along the vessel centres. Thereafter, we apply a skeletonisation operation on the thinned vessel segments to detect the vessel centrelines. Skeletonisation is a binary morphological operation that removes pixels on the boundaries of objects without destroying the connectivity in an eight-connected scheme [45]. The remaining pixels make up the image skeleton without affecting the general shape of the pattern. Therefore, the one pixel thin vessel centreline is obtained with a recognizable pattern of the vessel. The pixels that consist of vessel centreline are viewed as a series of specific centre points for the subsequent width measurements.

All edge points are detected using Inline graphic windows on the vessel centreline image using the following steps. First, we convolve the vessel centreline image with the window for the selected candidate points to be processed. We consider only three windowed centreline pixels, so that the positions of the three pixels along horizontal (Inline graphic) or vertical (Inline graphic) orientations are not repeated. Such windowed centreline pixels are aligned along one of 14 different possible orientations, illustrated in Fig. 8. Such aligned pixels as candidate pixels avoid vessel crossing to be detected with two adjacent branchings on the vessel centreline image. As shown in Fig. 9(A), the image pixels covered by the window consist of blue pixels and black pixels. The black pixels are validated as candidate pixels and the corresponding filter orientations along Inline graphic or Inline graphic axis are regarded unique. Considering there are two groups of filter orientations, (consisting of the dash-dot line and the solid line with three centreline pixels, respectively), we select the pixels with larger Inline graphic coordinates (black pixels) as candidate points for edge detection and the pixels with smaller Inline graphic coordinates are rejected.

Figure 8. Represents 14 possible windows with three unique orientations along its horizontal axis.

Figure 8

These Inline graphic windows are used to detect all edge points on the vessel centreline image. These windows are convolved with the vessel centreline image. The pixels inside each window are the connected pixels consisting of only three unique coordinates, or along the Inline graphic-axis, or along the Inline graphic-axis. We use black and pink dots to separately represent the possible positions of pixels involved in the window.

Figure 9. A schematic drawing that illustrates the processing steps of the width measurements.

Figure 9

(A) Illustration of the pixels with black color used for edge detection and with the blue pixels to be viewed as branch pixels that are rejected for edge detection. (B) Illustration of the process of width measurement, which is used to determine the detected edge points.

We linearly extrapolate the pixels which form the centreline and make rotation afterwards, as a result, each of the resultant profile contains widest segmented pixels and pixels from additional background region. The principle is to approximate the tangent of windowed centreline mentioned above at any point of it via the connected neighbor pixels in the local region. The resultant profiles perpendicularly cross through tangents and go through the pixel with central coordinate. For windowed centreline consisting of pixels with the same Inline graphic position, we directly find its perpendicular line. Such a resultant profile overlaps with vessel segment and its background, and the distances between the central coordinate pixels and the pixels from vessel segments are calculated. The edges of the extracted segments are located with the largest distances from the central coordinate points (centreline pixels). Fig. 9(B) illustrates such a process. In this figure, green solid lines indicate the observed retinal vessel edges. The line passing through the blue and black dots indicates the centreline. The thin black line BD is a vessel branch that should not be involved for edge detection. The black dots inside the red Inline graphic window form the centreline ABC. After a counterclockwise rotation of Inline graphic around the central point Inline graphic, the line segment ABC maps to Inline graphic. The extended line Inline graphic is the linear extrapolation of line Inline graphic until it reaches the blood vessel edge. The points Inline graphic and Inline graphic that are highlighted by the crosshairs are the intersection points between the blood vessels and line Inline graphic. These two points are the detected edge points and the Euclidean distance between the two points is registered as the vessel width. Fig. 10 is an illustration of the centreline (in blue) that is rotated 90 degree counterclockwise around the central point (red), to the green solid line. The black dash line is the resultant positions of the candidate centreline pixels after rotation and exploration. The black dash line is overlapped with some of the white segment pixels. The length of these overlapped pixels is the measured vessel width for the corresponding red centre point.

Figure 10. Illustration of width measurement via the retinal image segment.

Figure 10

The blue centreline is rotated Inline graphic counterclockwise around the red central point, to the green solid line, overlapping with some of the white segment pixels.

Results

The algorithm has been implemented in MATLAB version R2013a on a personal computer running Windows 7 with an Intel(R) Core(TM) i5-3470 CPU (3.20 GHz) and 8 GB of memory. On this platform, it takes about 24 seconds to process a DRIVE retina image to complete the segmentation. Considering that these results are obtained with MATLAB on a standard PC, the processing times are reasonable, and there is more headroom for improvement with further optimisation or customised hardware [46]. Even without speed improvements, our method can reasonably be incorporated into assisted-diagnosis systems and supply a result within an appropriate time frame (e.g. compared to a manual evaluation).

In the remainder of this section we first report qualitative results aimed at giving a visual appreciation for the quality of the vessel segmentation and vessel width measurements generated by our method. We then report the quantitative results for our method. The resultant vessel segmentation is calculated for images on the DRIVE database and compared with those reported by Jiang et al. [17], Perez et al. [27], and Zana et al. [20], Staal et al. [5] as well as human observation. The first three use unsupervised learning algorithms, and the last uses a supervised learning based algorithm. All these resultant segments are downloaded from the DRIVE database's website [47]. Typical vessel width measurements are performed on the REVIEW database. We compare the performance of our algorithm with the performance of two human experts. All these detected vessel edges are downloaded from the website containing the REVIEW database [34].

Qualitative segmentation results

To evaluate the performance of segmentation, we apply our approach to all 20 images of the test set of the DRIVE database. Considering that the masks depicting the FOV included with the DRIVE images are not enough to clean the noise edge of the FOV produced by applying algorithms (shown in Fig. 4 and Fig. 5), for our segmentation implementation, we used a FOV mask computed simply by Sobel edge detection before applying a morphological closing operation. The use of the Sobel operator is to mark features on each side of a wide ridge and the closing operation close regions where multiple detected edges of blood vessels are close together. The morphological closing operation is conducted via a line shaped structural element with length of 3 at 12 directions.

To begin, we apply our method to process the image named 02_test from DRIVE database for illustrative purposes, as the retinal image is clear and without complicating pathology requiring further processing. Following our proposed method, top-hat based morphology preprocessing is first applied on the selected channel shown in Fig. 2 for contrast enhancement. Morphology based spectral clustering is then carried out in order to partition the fundus region, as shown in two colour-coded regions, as shown in Fig. 3. One forms a larger texture region which includes most of the smaller blood vessels (blue region); the other mainly consists of major vessels (red). Afterwards, eigenvalue analysis of Hessian matrix is conducted for an enhanced image. This is illustrated in Fig. 4. To extract the blood vessels from the background, entropy-maximising binarization is applied to yield Fig. 5(A). We then perform an element-by-element multiplication of Fig. 4 and Fig. 5(A), followed by a global thresholding, to obtain an initial segmentation, as illustrated in Fig. 7(A). Using the earlier two-colour partition, the segmentation is separated into Fig. 7(B) and Fig. 7(C), which correspond to the blue and red regions in Fig. 2, respectively. At this stage, the images are likely to be over-segmented, where many non-vessel pixels have been misclassified as vessels. However, the majority of the vasculature is represented by one large connected structure in the binary image, whereas misclassified pixels tend to be clustered to form isolated objects. It is not difficult to see that there is relatively larger connected structure in Fig. 7(C) than Fig. 7(B). Even the connectivity of misclassified pixels associated with isolated objects is also larger in Fig. 7(C) than the connected structure in related to small blood vessels.

By applying different connectivity constraints to the two sub-segmentations, we extract the curvature based segmentation, illustrated in Fig. 5(B), from the background. The clear segmentation is illustrated in Fig. 6(B). It is clear that a pronounced dark region runs through some of the vessels, indicated by green arrows. Then a second binarization is performed, with a larger threshold value to eliminate the effect of central light reflex, to produce the image in Fig. 6(A), where there are no dark regions going through of large pixels. To evaluate the retinal segmentation, we overlay the segmentation generated according to our method with gold standard segmentation. In Fig. 7(D), the blue colour indicates the overlapping pixels between the two segmentation, the yellow colour indicates the pixels found to be vessels by our proposed algorithm (this means they are false positives) and the green colour indicates vessel pixels in the gold standard segmentation (this means they are false negatives). The Fig. 7(D) shows good overlapping between the two segmentations with slight errors.

Fig. 11 and Fig. 12 show the effect of images containing pathological tissues, corresponding to images 03_test and 08_test from DRIVE database, respectively. Their green channel-only images are shown in Fig. 11(A) and Fig. 12(A). The extracted enhanced image associated with the original image of 03_test after a global threshold and a global connectivity constraint is shown in Fig. 11(C). It has been split into two parts according to the colour coded mapping shown in Fig. 11(B). The part in relation to blue coded mapping is shown in Fig. 11(D) is a region consisting of obvious pathological tissues, highlighted by yellow dash and green dash-dot lines. The diseased tissues circled by yellow dash line can be removed via specific connectivity constraint but leaving the potion circled by green dash-dot line that could not be removed, illustrated in Fig. 11(E). The binarisation via thresholded entropy used to diminish the central light reflex tends to broaden vessel size compared to the vessel size from extracted enhanced image. It leads to an increment of the noise effect. The pathological region that could not be removed thoroughly is one of reasons which lead to false identification of blood vessels. This then leads to an increased false positive rate of the resultant segment, which will be further explained and discussed in the quantitative analysis subsection.

Figure 11. An example showing noise effects from a pathological image.

Figure 11

(A) The green channel of original image named 03_test. (B) Colour coded mapping. (C) The extracted enhanced image after a global threshold and a global connectivity constraint. (D) The part in relation to blue coded mapping with pathological regions indicated by yellow dash and green dash-dot lines. (E) Final segmentation with part of pathological tissue existing indicated by green dash-dot line.

Figure 12. A further example showing the source of noise effects.

Figure 12

(A) The green channel of original image named 08_test. (B) Colour coded mapping. (C) Final segmentation with noise effect partly from pathological tissue, indicated by yellow dash line, and partly from optic disk, indicated by green dash-dot line. (D) The superposition of the segmentation produced by our algorithm and manual segmentation, the yellow part of which represents the misclassified pixels of retinal blood vessels.

Fig. 12(C) with the yellow dash-line further illustrates such a noise effect from pathological tissue. Though the coloured mapping shown in Fig. 12(B) has recognized the pathological tissue region, the tight connectivity between the diseased tissue and retinal vessels results in difficulty in the separation of pathological region. The region highlighted by green dash-dot line shows the noise from optical disk. We apply the red channel image to detect the optical disk region with morphology operation to remove the noise effect, but only part of the noise is removed, which is another reason leading to false segmentation of blood vessel. The comparison with manual segmentation is illustrated in Fig. 12(D). The segmentation with yellow coded is the false identification of blood vessels, most of which is concentrated in the pathological and optical disk region.

More results of the proposed method that are related to the difference size of noise corresponding to the coloured mapped partitions, as applied to images 04_test and 14_test in the DRIVE database, are illustrated in Fig. 13.

Figure 13. Overview of the main steps taken by our algorithm when processing more fundus images.

Figure 13

From left to right, they are the green channels of the original images named 04_test and 13_test from DRIVE database, colour-coded mapping of the two partitions of vessel texture, results of enhanced images via eigenvalue analysis, masks using binarisation via thresholded entropy with difference size of noise corresponding to the coloured mapped partitions, final clear segmentation with remove of central light reflex, superposition of segments between the gold standard for retinal segmentation and the segmentation produced by the proposed algorithm.

Quantitative segmentation results

Three measures are used to quantitatively assess our algorithm's performance: true positive rate (TPR), false positive rate (FPR) and accuracy (ACC). Note that TP and TN are the number of blood vessel pixels and background pixels which are correctly detected, respectively; FP is the number of pixels not belonging to a vessel, but is recognised as one, and FN is the number of pixels belonging to a vessel, but is recognised as background pixels, mistakenly. Based on these definitions, TPR, FPR and ACC are defined as follows:

graphic file with name pone.0095943.e062.jpg (8)
graphic file with name pone.0095943.e063.jpg (9)
graphic file with name pone.0095943.e064.jpg (10)

The three measures are calculated for the final segmentations from our algorithm, as well as several other retina vessel segmentation algorithms in the literature. We divide the 20 test images from DRIVE database into three classes: the images with approximately uniform illumination throughout the background and well localised central light reflex (Class 1); the images with approximately uniform illumination but with broken vessels due to central light reflex effect (Class 2); the images with non-uniform illumination and pathological tissues (Class 3). Characteristics of these three class members are easily observed. According to different classes of the images, we adopt different steps of our algorithm. For example, well localised central light reflex is viewed as the large vessels with thin central light reflex effect compared to the space between the vessels and their neighbours. The uniform illumination is viewed such that after a global threshold, the size of background pixels is distributed uniformly, and are not obviously large in one region and small in another. The pathological tissues in retinal images show complex morphology, appearing as a bright protuberance on or around a vessel branch. For the first class of the images with enough spacing between two vessels, we apply multiplication between curvature segmentation and binarisation, with morphological closing operation to eliminate the central light reflex. We adopt disk-shaped structuring element with the radius of 2 pixels to conduct morphological closing operation. For the second class of the images, where the spacing is small and the large vessels show low contrast, we apply entropy filtering to eliminate the central light reflex, after multiplication operation for segmentation. For the third class of the images, we apply the entire set of operations of our algorithm. In Table 1, we list the steps involved to process the three classes of retina images.

Table 1. The steps are involved to process three class members of retina images.

Class member Class 1 Class 2 Class 3
Steps numbered (shown in Fig. 1) 2+5 2+3+5 1–5

The numbered steps are illustrated in Fig. 1.

The average quantitative results of the three classes of images are listed in Tables 24, while the average results of the overall set of 20 images are listed in Table 5. The quantitative performance of our method with the other approaches in terms of TPR, FPR, and ACC is compared as well as the percentage of improvement (Imp) between our method (Inline graphic) and the methods represented in literature (Inline graphic). The percentage of improvement satisfies the equation: Inline graphic. The hand segmented images from the first manual observer are used as the benchmark. True and false positive rates (TPR and FPR) are included where these are available in the DRIVE database web site. Improving on the accuracy score of the second observer is not necessarily beneficial, since the choice of the first observer as the benchmark is arbitrary [11].

Table 2. Quantitative evaluation of vessel segmentation algorithms related to the first class of the images.

Method TPR FPR ACC Improvement (Inline graphic) TPR FPR ACC
Our method 0.6988 0.0267 0.9504
Jiang et al. [17] 0.5993 0.031 0.9238 our method vs Jiang et al. 17 −0.14 2.9
Perez et al. [27] 0.5772 0.0367 0.9172 our method vs Perez et al. 21.1 −27.2 3.6
Staal et al. [5] 0.674 0.0178 0.9566 our method vs Staal et al. 3.7 0.5 −0.6
Zana et al. [20] 0.6287 0.0197 0.9375 our method vs Zana et al. 11.1 35.53 1.4
2nd observer 0.7825 0.0378 0.9460 our method vs 2nd observer −10.7 −29.37 0.5

Comparison of performance between the recent studies according to the first class of the images, including 6th, 9th, 12th, 17th, 18th, 20th test images from the DRIVE database.

Table 4. Quantitative evaluation of vessel segmentation algorithms related to the third class of the images.

Method TPR FPR ACC Improvement (Inline graphic) TPR FPR ACC
Our method 0.7636 0.0348 0.9478
Jiang et al. [17] 0.6182 0.0306 0.9245 our method via Jiang et al. 24 13.73 2.5
Perez et al. [27] 0.7229 0.0508 0.9202 our method via Perez et al. 5.5 −31.5 3.0
Staal et al. [5] 0.6952 0.0211 0.9427 our method via Staal et al. 9.8 64.93 0.6
Zana et al. [20] 0.5915 0.0152 0.9343 our method via Zana et al. 29.1 128.9 1.4
2nd observer 0.7118 0.0202 0.9466 our method via 2nd observer 7.3 72.28 0.1

Comparison of performance between the recent studies according to the second class of the images, including 2th, 3th, 4th, 7th, 8th, 10th, 13th, 14th test images from the DRIVE database.

Table 5. Quantitative evaluation of vessel segmentation algorithms related to the 20 images from the test set.

Method TPR FPR ACC Improvement (Inline graphic) TPR FPR ACC
Our method 0.7556 0.0344 0.9475
Jiang et al. [17] 0.6220 0.0318 0.9244 our method via Jiang et al. 21.5 8.18 2.7
Perez et al. [27] 0.7123 0.0524 0.9196 our method via Perez et al. 6.1 −34.35 3.0
Staal et al. [5] 0.6969 0.0214 0.9441 our method via Staal et al. 8.4 60.75 0.4
Zana et al. [20] 0.6125 0.0163 0.9372 our method via Zana et al. 23.4 111.04 1.1
2nd observer 0.7316 0.0208 0.9470 our method via 2nd observer 3.3 65.38 0.05

Validation of width measurement accuracy

Comparison with manually detected edge images

In order to evaluate the reliability of automatic vessel edge detection including width measurements, we make use of the images included in the REVIEW database. This comprises of three Image Sets (IS) containing full fundus images: high-resolution (HRIS), central light reflex (CLRIS) and vascular disease (VDIS) with each set containing representative images that are particularly large, show visible pathologies and have vessels exhibiting prominent central light reflexes, respectively. A fourth set, the kick-point image set (KPIS), contains downsampled high-resolution images of several large diameter non-tortuous vessels. The database also offers manual width measurements made by three independent observers using a custom software tool for marking vessel edge points, so that the ground truth edge points are considered to be the average of the measurement made by the three observers at the same location in a vessel segment. A total of around 2000 locations are available for vessel width analysis.

Considering the similarity between the vessel widths in ground truth manually delineated edge points and the width measured entirely by our algorithm, width measurement accuracy cannot readily be quantified. The edge image produced by our method will differ from the manual edge detection, which will cause measurement locations and angles to not match up. One way, however, results in good agreement with the manually delineated vessels by overlaying the vessel edge points calculated from our algorithm located on top of the manually segmented images. In order to achieve the manually segmented images, we conduct a morphological close operation on the ground truth points with structuring elements of size Inline graphic and this closed version is used as the ground truth segments. The closed versions of the manually delineated edges are obtained with variable Inline graphic, only if at this value, all edge points can be connected to form segments—this is for accurate computation and comparison. We locate the centreline on the overlay image, where the centreline is produced using morphological thinning operation on our segments for the calculation of the widths in relation to the vessels. The resultant images with such processing are illustrated in Fig. 14(A), (C), (E), (G), which correspond to the HRIS, CLRIS, VDIS, and KPIS respectively. The corresponding images used from the REVIEW database are named as: HRIS001, CLRIS002, VDIS006, KPIS001 image datasets. These images show good agreement between the edge points produced by our algorithm and the ground truth segments, with centreline (black line) within the ground truth segments, with most pixels within the middle. In order to reflect the error in width measurement between the proposed algorithm and the ground truth, the morphological closing operation is also conducted on the selected edge points from our algorithm that are matched with the edge points detected manually. The matched edge points are calculated as follows. The morphological dilation operation on the closed version of manual edge points is obtained and the dilated version is used as the mask to select the position of edge points for comparison in width measurement. The difference between the two closed version of edge image are illustrated in Fig. 14(B), (D), (F), (H).

Figure 14. Comparison between manually detected edge images using the image datasets of HRIS, CLRIS, VDIS, and KPIS.

Figure 14

(A), (C), (E), (G) Overlay between the vessel edge points calculated from our algorithm located on top of the manually segmented images with our centreline going through the middle part of the vessel segments. (B), (D), (F), (H) The difference between the two closed version of edge image from our algorithm and background truth, where the value of corresponding standard deviation is as: 1.11, 1.49, 1.55, 1.32.

The errors mainly arise from the following: (i) The vessel width calculated using our algorithm is 1–2 pixels wider than the ground truth, i.e. Fig. 14(B) and (D); (ii) as illustrated in Fig. 14(D), the tight border of the image is not recognised by the binarisation, which results in the vessel pixels being misclassified as background; (iii) when conducting the morphological closing operation, the closed version tends to merge minor background pixels into vessels if the edge profiles fail to possess sufficient smoothness along the edges of vessels or if a small amount of real edge points occurring in the images are missed due to our edge detection algorithm. Such effects are illustrated by Fig. 14(F).

Quantification of the performance measures

In order to qualify the comparison of the images mentioned above, we select successful measurement percentages (labelled by Inline graphic), mean vessel widths (labelled by Inline graphic) and standard deviations of the measurement error Inline graphic. A successful measurement percentage means that each ground truth centre point should be associated with the closest detected centre point where the distance between both points is less than or equal to the true vessel width at that location. When determining comparable measurements for our algorithm, we keep the association only if the centreline calculated using the morphological thinning operation goes inside the vessel segments from ground truth data without running outside. A reduction in the measurement success percentage in these cases may indicate that the vessel is not detected. To quantify the measures of mean vessel widths, the points afforded by ground truth are used. For our algorithm, instead of computing the Euclidean distance between each pair of points from detected edges, the number of pixels in each segment, cf. Fig. 15(C) and (D), is calculated, which is then divided by the number of the pixels of the associated centreline, i.e. Fig. 15(E) and (F). The segments are obtained via morphological closing operations on edge detected images, cf. Fig. 15(A) and (B), and the centrelines are archived afterwards via morphological thinning operations on these segments. The performance of measured errors is evaluated by considering the standard deviation of errors. The errors in an image are defined as the difference between the morphological closed version of detected edge points and ground truth points at the same position of the vessels. In order to obtain the same position, straight lines are drawn that go through each pair of coordinates produced by averaged human observations Fig. 15(H). The color-coded image derived from each pair of coordinates of background truth. The error image, i.e. Fig. 15(G), is the difference between the our segment image cf. Fig. 15(D) and background segmentation, i.e. Fig. 15(C). We calculate the number of pixels in the region, i.e. shown in Fig.16, that the error image, i.e. Fig. 15(G), overlaps with the image of straight lines, i.e. shown in Fig. 15(H). The number of error pixels are then squared and summed up, and the total number of lines, shown in Fig. 15(H) are used to calculate the standard deviation. The method to qualify images for the performance measurement avoids such an issue that ground truth points cannot be uniquely matched with detected points when the detection is successful. This is due to different size of space existing in the ground truth data [11].

Figure 15. Illustration of the procedure to calculate width of vessel segment and the relevant deviation according to the VDIS image.

Figure 15

(A) Background truth plot. (B) Detected edge via our method in the region of interest in relation to background truth. (C) and (D) Illustration of segmentation of (A) and (B). (E) and (F) Illustration of centreline of (C) and (D). (G) The error image of difference between (C) and (D). (H) Colour coded lines between each pair of ground truth coordinates.

Figure 16. Extraction of the error image in the region that the error image is overlapped with the straight line based image of Fig. 15(H).

Figure 16

The performance of the proposed edge detection method is evaluated based on four retina images, related to the image sets: HRIS, CLRIS, VDIS, KPIS. The HRIS image sets are downsampled by a factor of four before being input into the test algorithms, and it is these downsampled measurements that are reported in the REVIEW database. Since manual measurements are made on the original images, vessel widths are considered to be known to an accuracy of Inline graphic pixels [35]. Table 6 presents the performance measurements on REVIEW database. The vessel width measurements obtained using the edges produced by our method are compared against the measurements carried out by the human observers. For comparison purposes, the relevant results according to other methods in the literature are involved in the table. These methods include: that of Gregson et al. [48], Graph et al. based method [22], 1D Gaussian (1DG) [22] and 2D Gaussian (2DG) [50]. The results listed in the Table 6 above the double line use the datasets from the REVIEW database, named as: HRIS001, CLRIS002, VDIS006, KPIS001. The results listed in the table below the double line are averaged results according to the whole REVIEW database, which lead to a slightly different representation of results, but these results can be referred to for comparison.

Table 6. Comparison of performance between the result of our edge detection method and ground truth data points from the REVIEW database.
HRIS CLRIS VDIS KPIS
Method Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic
Our method 100 5.11 1.11 100 12.78 1.49 100 9.22 1.55 100 7.51 1.32
Standard 100 4.69 0.00 100 14.49 0.00 100 8.67 0.00 100 7.54 0.00
O1 100 4.58 0.34 100 14.44 0.52 100 8.65 0.52 100 7.95 0.45
O2 100 4.68 0.29 100 14.50 0.69 100 9.01 0.69 100 7.56 0.31
O3 100 4.80 0.27 100 13.92 0.54 100 8.48 0.54 100 7.61 0.33
Gregson 100 7.64 1.48 100 12.80 2.84 100 10.07 1.49 100 7.29 0.60
1DG 99.6 3.81 0.90 98.6 6.30 4.14 99.9 5.78 2.11 100 4.95 0.40
2DG 98.9 4.18 0.70 26.7 7.00 6.02 77.2 6.59 1.33 100 5.87 0.34
Graph 100 4.56 0.57 94.1 14.05 1.78 96.0 8.35 1.43 99.4 6.38 0.67

In this Table, successful measurement percentages is labeled by Inline graphic, mean vessel widths is labeled by Inline graphic, and standard deviation of the measurement error is labeled Inline graphic. The vessel width measurements obtained using the edges produced by our method are compared against the measurements carried out by the human observers and methods in literature. These literature methods include: that of Gregson et al. [48], Graph et al. based method [49], 1D Gaussian (1DG) [22] and 2D Gaussian (2DG) [50]. The results listed in the table above the double line use the datasets from the REVIEW database, named as: HRIS001, CLRIS002, VDIS006, KPIS001. The results listed in the table below the double line are averaged results according to the whole REVIEW database, which lead to slightly different representation of results, but these results can be referred for comparison.

Discussion

The results reported in Tables 25 show that, the values related to true positive rate calculated using our algorithm exceeds recently published results (increased from Inline graphic to Inline graphic), and are comparable to the performance of human observers (increased up to Inline graphic). This is the most distinct improvement of our algorithm. In addition, the averaged accuracy calculated using our algorithm to process the third class of images outperforms previous methods (increased from Inline graphic to Inline graphic), illustrated in Table 4. That is to say that the combination operation of our method is especially effective in dealing with complex cases, where both non-uniform illumination and pathological tissues are present. The average accuracy of our segmentation approach in relation to the first two classes of the images, reported in Tables 2 and 3, is slightly weaker but comparable to the methods related to the work carried out by Staal et al. (increased Inline graphic) and Zana et al. (increased Inline graphic). This is mainly because no more post-processing is used to remove the possible noise from background, and the interim binarisation steps tends to enlarge effects of noise when using it to eliminate the central light reflex. Our method performs significantly better than the recently reported algorithms. As shown in Table 5, our performance measures for both pathological and normal images are higher (increased from Inline graphic to Inline graphic) than those achieved by the other authors methods. Though our method shows increased errors generated in the misclassification of retina vessels, i.e. false positive rate when compared with the method reported by Zana et al. (increased Inline graphic when processing Class 3 images and Inline graphic when processing all images), the averaged classification accuracies are still Inline graphic and Inline graphic. The reason for the increased false positive rate has been discussed in the previous section, with the illustrations in Fig. 11 and Fig. 12. The main types of errors in relation to the true positive rate come from partially or completely missing thin vessel branches. The expected consequence is produced mainly in thin low-contrasted vessels. It is normally related to curvature detection, which is used for localisation of blood vessels but unable to generate significant responses in regions with weakened intensity transition. The need to discriminate between valid segments and background noise prevent the reconstruction of some vessel areas.

Table 3. Quantitative evaluation of vessel segmentation algorithms related to the second class of the images.

Method TPR FPR ACC Improvement (Inline graphic) TPR FPR ACC
Our method 0.8045 0.0416 0.9444
Jiang et al. [17] 0.7091 0.05 0.9189 our method vs Jiang et al. 13.5 −16.8 2.8
Perez et al. [27] 0.7927 0.0779 0.9245 our method vs Perez et al. 1.5 −46.60 2.2
Staal et al. [5] 0.7775 0.0287 0.9458 our method vs Staal et al. 3.5 60.28 −0.1
Zana et al. [20] 0.765 0.0266 0.9448 our method vs Zana et al. 5.2 56.39 −0.04
2nd observer 0.7967 0.0278 0.9497 our method vs 2nd observer 1.0 49.64 −0.6

Comparison of performance between the recent studies according to the second class of the images, including 1th, 5th, 11th, 15th, 16th, 19th test images from the DRIVE database.

For reproducibility, the relevant parameters used by our segmentation algorithm are: Structure elements to produce top-hat preprocessing: disk shaped with radii from 10 to 60; the structure element used for morphological H-minima transform to achieve texture mapping: disk shaped with radii from 4 (only for 08_test image) or 8 (all the remaining images from the test sets); intensity threshold value to produce mask using binarisation with threshold chosen for entropy maximisation: from 0.3 to 0.8; intensity threshold value to produce entropy filtering regarding large vessels with central light reflex: from 0.8 to 3; Alternatively, we also suggest to use gray level of colour image, instead of green channel image, to achieve entropy filtered vessel segmentation in the relevant large vessel regions; the threshold used for detection vessel intensity (larger than): from 0.04 to 0.2; the connectivity constraint (larger than): from 5 to 16.

The results presented in Table 6 are the quantification of performance in relation to our edge detection algorithm. All of the edge profiles detected by our edge detection algorithm are successful. Different from traditional evaluation of edge images for width measurements, we propose the evaluation method according to the number of pixels shown in a segment image where the edges are morphologically closed to avoid the mismatch in position of each pairs of edge pixels. The mean vessel width estimates more consistently close to the ground truth, with difference around 1 to 2 pixels or so. The average of standard deviation is comparable with methods in literature, with slightly large compared to ground truth. The reasons of the errors occurred have been discussed and illustrated in Fig. 14(B), (D), (F), (H), mainly from the misclassified pixels as discussed before.

Conclusion

As distinct from multiscale detection algorithms, which are designed for specific range of vessel sizes, our proposed combined approach for retinal image segmentation adaptively explores local intensity characteristics and local vessel width information via conducting colour coded texture mapping. Two types of feature textures are investigated to identify noise regions with different size. A major feature of the method is its adaptability to particular image intensity properties with different noise contents. In addition, the algorithm described here automates the analysis of retinal vessel widths. It allows the fast calculation of vessel widths all along the length of each vessel rather than at specific points of interest. The quantitative performance results of both segmentation and width measurement show that our method effectively detects the blood vessels with average accuracy of above Inline graphic, average TPR of Inline graphic, average FPR of Inline graphic, and the blood vessel width with size of 5.11, 12.78, 9.22 and 7.51 (in pixels) related to HRIS, CLRIS, VDIS and KPIS images, respectively.

Acknowledgments

We would like to thank Nanjing Nandian Technology Co. Ltd., China for supporting the project.

Funding Statement

Nanjing Nandian Technology PTY LTD, China, is the source of funding that has supported the work. The URL of funder's website is: http://3150724.czvv.com/. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

References

  • 1. Teng T, Lefley M, Claremont D (2002) Use of two-dimensional matched filters for estimating a length of blood vessels newly created in angiogenesis process. Medical & Biological Engineering & Computing 40: 2–13. [DOI] [PubMed] [Google Scholar]
  • 2. Mendonça AM, Campilho A (2006) Segmentation of retinal blood vessels by combining the detection of centerlines and morphological reconstruction. IEEE Transactions on Medical Imaging 25: 1200–1213. [DOI] [PubMed] [Google Scholar]
  • 3. Hammond S, Wells J, Marcus D, Prisant LM (2006) Ophthalmoscopic findings in malignant hypertension. The Journal of Clinical Hypertension 8: 221–223. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Ghorbanihaghjo A, Javadzadeh A, Argani H, Nezami N, Rashtchizadeh, et al (2008) Lipoprotein(a), homocysteine, and retinal arteriosclerosis. Molecular Vision 14: 1692–1697. [PMC free article] [PubMed] [Google Scholar]
  • 5. Staal J, Abramoff M, Niemeijer M, Viergever M, van Ginneken B (2004) Ridge-based vessel segmentation in color images of the retina. IEEE Transactions on Medical Imaging 23: 501–509. [DOI] [PubMed] [Google Scholar]
  • 6. Kumar S, Madheswaran M (2010) Automated thickness measurement of retinal blood vessels for implementation of clinical decision support systems in diagnostic diabetic retinopathy. World Academy of Science, Engineering and Technology 40: 393–397. [Google Scholar]
  • 7. Abramoff M, Garvin M, Sonka M (2010) Retinal imaging and image analysis. IEEE Reviews in Biomedical Engineering 3: 169–208. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. Fraz M, Remagnino P, Hoppem A, Uyyanonvara B, Rudnicka A, et al. (2012) Blood vessel segmentation methodologies in retinal images—a survey. Computer Methods and Programs in Biomedicine 108: 407–433. [DOI] [PubMed] [Google Scholar]
  • 9. Honale SS, Kapse VS (2012) A review of methods for blood vessel segmentation in retinal images. International Journal of Engineering Research & Technology 1: 1–4. [Google Scholar]
  • 10. Ricci E, Perfetti R (2007) Retinal blood vessel segmentation using line operators and support vector classification. IEEE Transactions on Medical Imaging 26: 1357–1365. [DOI] [PubMed] [Google Scholar]
  • 11.Bankhead P, Scholfield CN, McGeown JG, Curtis TM (2012) Fast retinal vessel detection and measurement using wavelets and edge location refinement. PLoS ONE 7: art. no. e32435. [DOI] [PMC free article] [PubMed]
  • 12. Nekovei R, Ying S (1995) Back-propagation network and its configuration for blood vessel detection in angiograms. IEEE Transactions on Neural Networks 6: 64–72. [DOI] [PubMed] [Google Scholar]
  • 13. Soares J, Leandro J, Cesar R, Jelinek H, Cree M (2006) Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification. IEEE Transactions on Medical Imaging 25: 1214–1222. [DOI] [PubMed] [Google Scholar]
  • 14. Tolias Y, Panas S (1998) A fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering. IEEE Transactions on Medical Imaging 17: 263–273. [DOI] [PubMed] [Google Scholar]
  • 15. Simó A, de Ves E (2001) Segmentation of macular fluorescein angiographies. a statistical approach. IEEE Transactions on Medical Imaging 34: 795–809. [Google Scholar]
  • 16. Freeman W, Adelson E (1991) The design and use of steerable filters. IEEE Transactions on Pattern Analysis and Machine Intelligence 13: 891–906. [Google Scholar]
  • 17. Jiang X, Mojon D (2003) Adaptive local thresholding by verification-based multithreshold probing with application to vessel detection in retinal images. IEEE Transactions on Pattern Analysis and Machine Intelligence 25: 131–137. [Google Scholar]
  • 18. Chaudhuri S, Chatterjes S, Katz N, Nelson M, Goldbaum M (1989) Detection of blood vessels in retinal images using two-dimensional matched filters. IEEE Transactions on Medical Imaging 8: 263–269. [DOI] [PubMed] [Google Scholar]
  • 19. Villalobos-Castaldi F, Felipe-Rivern E, Sánchez Fernández L (2010) A fast, efficient and automated method to extract vessels from fundus images. Journal of Visualization 13: 263–270. [Google Scholar]
  • 20. Zana F, Klein J (2001) Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation. IEEE Transactions on Image Processing 10: 1010–1019. [DOI] [PubMed] [Google Scholar]
  • 21. Ayala G, Leon T, Zapater V (2005) Different averages of a fuzzy set with an application to vessel segmentation. IEEE Transactions on Fuzzy Systems 13: 384–393. [Google Scholar]
  • 22. Zhou L, Rzeszotarski M, Singerman L, Chokreff J (1994) The detection and quantification of retinopathy using digital angiograms. IEEE Transactions on Medical Imaging 13: 619–626. [DOI] [PubMed] [Google Scholar]
  • 23. Delibasis K, Kechriniotis A, Tsonos C, Assimakis N (2010) Automatic model-based tracing algorithm for vessel segmentation and diameter estimation. Methods and Programs in Biomedicine 100: 108–122. [DOI] [PubMed] [Google Scholar]
  • 24. Vázquez SG, Cancela B, Barreira N, Penedo MG, Rodríguez Blanco M, et al. (2013) Improving retinal artery and vein classification by means of a minimal path approach. Machine Vision and Applications 24: 919–930. [Google Scholar]
  • 25.Frangi AF, Niessen WJ, Vincken KL, Viergever MA (1998) Multiscale vessel enhancement filtering. In: Proceedings of the Third International Conference on Medical Image computing and Computer-Assisted Intervention—MICCAI 1998. volume 1496 of Lecture Notes in Computer Science, pp. 130–137. [Google Scholar]
  • 26.Martinez-Perez M, Hughes A, Stanton A, Thom S, Bharath A, et al. (1999) Retinal blood vessel segmentation by means of scale-space analysis and region growing. In: Proceedings of the Second International Conference on Medical Image Computing and Computer-Assisted Intervention, London, UK: Springer-Verlag, volume 19–20 . pp. 90–97. [Google Scholar]
  • 27. Martinez-Perez M, Hughes A, Thom S, Bharath A, Parker K (2007) Segmentation of blood vessels from red-free and fluorescein retinal images. Medical Image Analysis 11: 47–61. [DOI] [PubMed] [Google Scholar]
  • 28. Vermeer K, Vos F, Lemij H, Vossepoel A (2004) A model based method for retinal blood vessel detection. Computers in Biology and Medicine 34: 209–219. [DOI] [PubMed] [Google Scholar]
  • 29. Mahadevan V, Narasimha-Iyer H, Roysam B, Tanenbaum H (2004) Robust model-based vasculature detection in noisy biomedical images. IEEE Transactions on Information Technology in Biomedicine 8: 360–376. [DOI] [PubMed] [Google Scholar]
  • 30. Kass M, Witkin A, Terzopoulos D (1998) Snakes: active contour models. International Journal of Computer Vision 1: 321–331. [Google Scholar]
  • 31. Sum KW, Cheung PYS (2008) Vessel extraction under non-uniform illumination: a level set approach. IEEE Transactions on Biomedical Engineering 55: 358–360. [DOI] [PubMed] [Google Scholar]
  • 32. von Luxburg U (2007) A tutorial on spectral clustering. Statistics and Computing 17: 395–416. [Google Scholar]
  • 33. Pajak R (2003) Progress towards automated diabetic ocular screening: A review of image analysis and intelligent systems for diabetic retinopathy. Opto-Electronics Review 11: 237–241. [DOI] [PubMed] [Google Scholar]
  • 34.University of Lincoln (2013) Retinal Image Computing & Understanding. Available: http://reviewdb.lincoln.ac.uk/REVIEWDB/REVIEWDB.aspx. Accessed 2013 Oct.
  • 35. Al-Diri B, Hunter A, Steel D (2009) An active contour model for segmenting and measuring retinal vessels. IEEE Transactions on Medical Imaging 28: 1488–1497. [DOI] [PubMed] [Google Scholar]
  • 36. Hoover A, Kouznetsova V, Goldbaum M (2000) Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response. IEEE Transactions on Medical Imaging 19: 203–210. [DOI] [PubMed] [Google Scholar]
  • 37. Miri M, Mahloojifar A (2011) Retinal image analysis using curvelet transform and multistructure elements morphology by reconstruction. IEEE Transactions on Medical Imaging 58: 1183–1192. [DOI] [PubMed] [Google Scholar]
  • 38. Yin XX, Ng BWH, Yang Q, Pitman A, Ramamohanarao K, et al. (2012) Anatomical landmark localization in breast dynamic contrast-enhanced MR imaging. Medical & Biological Engineering & Computing 50: 91–101. [DOI] [PubMed] [Google Scholar]
  • 39. Roerdink JB, Meijster A (2001) The watershed transform: Definitions, algorithms and parallelization strategies. Fundamenta Informaticae 41: 187–228. [Google Scholar]
  • 40. Pal N, Pal S (1991) Entropy: A new definition and its applications. IEEE Transactions on Systems, Man and Cybernetics 21: 1260–1270. [Google Scholar]
  • 41.Spencer WH (1996) Ophthalmic Pathology: An Atlas and Textbook. Philadelphia, PA: Elsevier—Health Sciences Division.
  • 42. Nguyen UT, Bhuiyana A, Park A, Ramamohanaraoa K (2013) An effective retinal blood vessel segmentation method using multi-scale line detection. Pattern recognition 46: 703–715. [Google Scholar]
  • 43. Bhuiyan A, Kawasaki R, Lamoureux E, Kotagiri R, Wong T (2013) Retinal artery-vein caliber grading using colour fundus imaging. Computer Methods and Programs in Biomedicine 111: 104–114. [DOI] [PubMed] [Google Scholar]
  • 44. Sparavigna A, Marazzato R (2010) An image-processing analysis of skin textures. Skin Research and Technology 16: 161–167. [DOI] [PubMed] [Google Scholar]
  • 45. Louisa L, Lee SW, Suen C (1992) Thinning methodologies—a comprehensive survey. IEEE Transactions on Pattern Analysis and Machine Intelligence 14: 869–885. [Google Scholar]
  • 46.Nooshabadi S, Abbott D, Eshraghian K, Montiel-Nelson JA (1997) Gaas asynchronous morphological processor for interactive mobile telemedicine. In: Proc. 14th Australian Microelectronics Conference (MICRO '97), Melbourne, Australia. pp. 29–33.
  • 47.ISI (2013) DRIVE: Digital Retinal Images for Vessel Extraction. Available: http://www.isi.uu.nl/Research/Databases/DRIVE/. Accessed 2013Oct.
  • 48. Gregson P, Shen Z, Scott R, Kozousek V (1995) Automated grading of venous beading. Computers and Biomedical Research 28: 291–304. [DOI] [PubMed] [Google Scholar]
  • 49. Xu X, Niemeijer M, Song Q, Sonka M, Garvin M, et al. (2011) Vessel boundary delineation on fundus images using graph-based approach. IEEE Transactions on Medical Imaging 30: 1184–1191. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50. Lowell J, Hunter A, Steel D, Basu A, Ryder R, et al. (2004) Measurement of retinal vessel widths from fundus images based on 2-D modeling. IEEE Transactions on Medical Imaging 23: 1196–1204. [DOI] [PubMed] [Google Scholar]