Table 1. Statistics of data collection.
Values in parentheses are for the highest resolution shell.
| Beamline | BL41XU, SPring-8 |
| Detector | MX225HE |
| Crystal-to-detector distance (mm) | 320 |
| Wavelength (Å) | 1.0000 |
| No. of images | 180† |
| Oscillation range (°) | 0–180 |
| Resolution range (Å) | 48.89–3.73 (3.96–3.73) |
| Total No. of reflections | 281233 (35593) |
| No. of unique reflections | 94516 (13239) |
| Space group | P21 |
| Unit-cell parameters (Å, °) | a = 93.3, b = 186.0, c = 287.8, β = 93.3 |
| Completeness (%) | 92.7 (81.2) |
| R meas ‡ (%) | 22.7 (78.3) |
| Multiplicity | 2.98 (2.69) |
| 〈I/σ(I)〉 | 5.28 (1.71) |
| Mosaicity (°) | 0.514 |
| Wilson B factor (Å2) | 66.13 |
37 out of 180 frames were omitted in data processing.
R