Abstract
Introduction. Inferior alveolar nerve transposition (IANT) is a surgical technique used in implantoprosthetic rehabilitation of the atrophic lower jaw which has not been well embraced because of the high risk of damage to the inferior alveolar nerve (IAN). There are cases in which this method is essential to obtain good morphologic and functional rebalancing of the jaw. In this paper, the authors present their experience with IANT, analyzing the various situations in which IANT is the only surgical preprosthetic option. Methods. Between 2003 and 2011, 35 patients underwent surgical IANT at our center. Thermal and physical sensitivity were evaluated in each patient during follow-up. The follow-up ranged from 14 to 101 months. Results and Conclusion. Based on our experience, absolute indications of IANT are as follows: (1) class IV, V, or VI of Cawood and Howell with extrusion of the antagonist tooth and reduced prosthetic free space; (2) class V or VI of Cawood and Howell with presence of interforaminal teeth; (3) class V or VI of Cawood and Howell if patient desires fast implantoprosthetic rehabilitation with predictable outcomes; (4) class VI of Cawood and Howell when mandibular height increase with inlay grafts is advisable.
1. Introduction
Inferior alveolar nerve transposition (IANT) is a surgical technique first described by Alling [1] and Fitzpatrick [2] in 1977.
This method, to be used in implantoprosthetic rehabilitation of the atrophic lower jaw, has not been well embraced because of the high risk of damaging the inferior alveolar nerve (IAN).
Currently, the use of short implants, osteoregeneration methods, and new prosthetic solutions using interforaminal implants have further reduced the use of IANT. However, there are cases in which the transposition of the alveolar nerve is essential to obtain good morphologic and functional rebalancing of the jaw. In this paper, the authors present their experience with IANT, analyzing the various situations in which IANT is the only surgical preprosthetic option for implantoprosthetic rehabilitation of the mandible.
2. Materials and Methods
We selected all patients who underwent IANT surgery between 2003 and 2011 at our center. We excluded all patients treated in 2012 to have adequate follow-up to obtain final data on sensitivity related to the IAN. All patients were reexamined clinically to evaluate the IAN function between September and October 2012. We also made a summary of the surgical technique used. We did not consider the stability of system using implantologic criteria because this was not considered part of our study. The implants were made by different manufacturers and were positioned by different operators. No implant loss was reported by patients. The minimum follow-up time was 12 months.
To evaluate sensory function, we used the method described by Becelli et al. in 2002 [3]. For the clinical evaluation, we used a two-point-discrimination test, the application of a painful stimulus and thermic sensitivity.
For the two-point discrimination, a compass with two blunt metal tips was used to avoid causing pain. The tips were applied on the skin of the chin, starting on the right, with the same pressure on both points. The two-point discrimination was evaluated for each patient until the patient could no longer correctly discriminate the two points. The same procedure was then repeated on the left side. A discriminated distance of 5 mm or less was considered a satisfactory sensory response.
Nociception was evaluated with a needle applied to the skin of the chin. Patients could choose among three types of feeling: numb, dull ache, or sharp. Nociceptive sensitivity was judged good if the patient had an adequate response to stimulation with increasing intensity.
Thermal sensitivity was tested using ice cubes and warmed metal utensils. First, the ice cubes were positioned on the lower lip of the patients, first on the right side and then on the left side. The patients were asked to report the degree of cold sensitivity they experienced using the following levels: high grade, medium grade, low grade, or no sensitivity. Five minutes later, a rounded metal tool was warmed using a flame and chilled to 38°C; temperature was checked using a thermometer. Then, the heated instrument was applied first on the right side and then on the left side. Patients were asked to report their sensitivity to heat using the same rating system described above for cold sensitivity. In our analysis, hypoesthesia was defined as an imperfect or incomplete response observed during the test, paresthesia was defined as a qualitative alteration characterized by numbness or altered sensation, and anesthesia was defined as the complete loss of sensitivity. The function of the IAN was assessed by the response to the three tests.
For all patients, we also considered the side and degree of the atrophy and the type of surgical instrumentation used. For atrophy assessment, we used the classification described by Cawood and Howell in 1988 [4] (Figure 1). In the literature, two types of instruments have been proposed to approach the IAN: rotary burrs (RB) and piezosurgery (PZ). In our study, both types of instruments were used, and we reported all adverse events related to the type of instrument used.
3. Surgical Technique
Before beginning the surgical procedure (Figure 2), accurate studies were performed using CT dentascan (Figure 3) to evaluate the position of the loop of the alveolar nerve in relation to the mental foramen [5, 6]. We preferred to use the surgical technique described by Rosenquist in 1992 [7] and modified in 1993 by Smiler [8] which takes into account intraoperative magnification with 4x lenses. However, we made our own modifications to the technique. We draw the bone flap with a RB of small size or a PZ, taking care to mark the front portion 2 mm posterior to the mental foramen. We defined the height of the flap, respecting the vestibular cortical bone and the relationship that exists between the chin foramen, loop of IAN, and course of the mandibular canal, as observed in CT scan (Figure 4). Generally, we designed a bone flap of up to 5 or 8 mm in height and maximum 1 cm in length. This bone flap's dimensions allowed adequate intraoperative vision. We elevated the bone flap using a curved Lambotte or Freer chisel, giving gentle taps or using them as levers. With the PZ, we opened the mental foramen, dissecting the chin branch. We worked the PZ along the walls of the alveolar canal to free the length of the nerve (Figure 5). Once we extracted the nerve up to about 3 mm from the rear edge, we designed the second bone flap centred to the mandibular canal. We opened the flap with a chisel and, with the aid of a PZ, we continued to follow the IAN in its course. If necessary, we repeated the operation more posteriorly. Previously, when fixtures were required intraoperatively, we inserted them in a single surgery. Current flowcharts no longer give importance to bicorticalism to avoid the development of low resistance areas in the jaw that could create structural integrity problems [9, 10]. After inserting the fixtures, we used autologous and/or heterologous bone grafts to cover the site of the bone flap, and then we covered it with a resorbable membrane. Usually, we positioned the nerve over the membrane, although more recently we preferred to lay it under the buccal periosteum. When bone grafts were needed, they were positioned immediately after the alveolar nerve transposition (Figure 6 and Figure 7). Fixtures could also be inserted as a second-step surgery after complete integration of the bone grafts (Figures 8 and 9).
4. Results
Between 2003 and 2011, 35 patients underwent surgical transposition of the inferior alveolar nerve, including 19 females and 16 males ranging from 23 to 78 years of age, with an average age of 55.8. The follow-up time period ranged from 14 to 101 months, with an average of 54.2 months. In total, we performed 49 IANTs; 26 on the right side and 23 on the left (Table 1).
Table 1.
Name | Age | Sex | Cawood-Howell classification | IANT | Anesthesia | Hypoaesthesia | Paresthesia | Surgical instrument | Follow-up (months) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DX | SN | DX | SN | DX | SN | DX | SN | Dx | Sn | PZ | RB | |||||||||
D | T | N | D | T | N | |||||||||||||||
1 | AS | 43 | F | VI | VI | X | X | X | 25 | |||||||||||
2 | FC | 54 | M | V | X | X | 85 | |||||||||||||
3 | DF | 24 | M | VI | X | X | X | 71 | ||||||||||||
4 | GS | 67 | F | VI | X | X | X | 28 | ||||||||||||
5 | DD | 56 | M | V | X | X | 94 | |||||||||||||
6 | SC | 65 | F | VI | VI | X | X | X | X | 38 | ||||||||||
7 | QK | 32 | M | VI | X | X | 45 | |||||||||||||
8 | FF | 56 | F | V | X | X | 96 | |||||||||||||
9 | H HF | 23 | F | V | VI | X | X | X | X | 14 | ||||||||||
10 | PL | 64 | F | VI | X | X | 16 | |||||||||||||
11 | TR | 33 | M | IV | X | X | 22 | |||||||||||||
12 | DR | 78 | M | V | X | X | 33 | |||||||||||||
13 | UI | 65 | F | VI | V | X | X | X | 50 | |||||||||||
14 | OF | 64 | F | IV | V | X | X | X | 16 | |||||||||||
15 | TO | 39 | F | VI | X | X | 73 | |||||||||||||
16 | ES | 43 | M | V | X | X | X | 82 | ||||||||||||
17 | PI | 54 | M | VI | X | X | 68 | |||||||||||||
18 | TE | 61 | M | VI | V | X | X | X | 25 | |||||||||||
19 | SA | 48 | F | VI | X | X | 20 | |||||||||||||
20 | ES | 65 | F | VI | VI | X | X | X | X | 26 | ||||||||||
21 | RT | 36 | M | VI | X | X | 71 | |||||||||||||
22 | FD | 54 | M | VI | X | X | 66 | |||||||||||||
23 | OR | 69 | F | V | X | X | 58 | |||||||||||||
24 | SA | 71 | F | V | VI | X | X | X | 72 | |||||||||||
25 | PL | 73 | M | VI | X | X | X | 59 | ||||||||||||
26 | IL | 66 | F | VI | X | X | 62 | |||||||||||||
27 | FR | 68 | M | VI | VI | X | X | X | 53 | |||||||||||
28 | SL | 67 | F | V | VI | X | X | X | 51 | |||||||||||
29 | AG | 74 | F | VI | VI | X | X | X | 101 | |||||||||||
30 | AS | 46 | F | VI | X | X | 85 | |||||||||||||
31 | FO | 65 | F | VI | V | X | X | X | 19 | |||||||||||
32 | F BT | 39 | M | VI | X | X | 63 | |||||||||||||
33 | DM | 73 | M | VI | VI | X | X | X | X | 73 | ||||||||||
34 | NB | 42 | F | VI | X | X | 49 | |||||||||||||
35 | GG | 76 | M | V | VI | X | X | X | 68 |
We performed the procedure for the correction of 33 class VI patients, 14 class V patients, and 2 class IV patients, according to the classification system of Cawood and Howell.
Complications were reported in 6 cases as follows: 1 (2.8%) case of transient anesthesia and 5 (14.3%) cases of transient hypoesthesia (spontaneously resolving after 6 months from the surgical procedure). No paresthesia was documented. Among the cases of hypoesthesia, 4 were of the discriminative type and 1 was of the thermal type with a greater impairment in recognizing cold. We decided not to make patients undergo ENG since remission of the symptoms was achieved after 6 months from the operation. Regarding instrumentation, we used RB in 16 patients with 4 (25% of the RB patients) adverse events occurring. We used PZ in 19 patients with 2 (10.5% of the PZ patients) adverse events occurring. The difference in the incidence of complications in the RB and in the PZ groups was found to not to be statistically significative (P = 0.3791).
Incidence of complications did not appear to be connected to Cawood and Howell class belonging (0.7337) and no significant difference according to age (0.7096) and sex was recorded (P = 0.3791).
Statistical analysis was performed with Fisher exact test.
5. Discussion
The IANT is not currently considered a safe method, and for that reason, it has received little consideration as surgical technique for preprosthetic preparation of the atrophic alveolar ridges in edentulous patients. Nevertheless, some authors continued to analyze the validity of this surgical technique, especially evaluating the residual functionality of the IAN following IANT [11–14]. The reported risk of damage to the IAN ranges between 33% and 87%; however, our results only documented a 2.8% risk of anesthesia and a 13.4% risk of hypoesthesia [11, 15, 16]. Certainly, IANT is associated with more risk than other jaw preparation techniques for implantoprosthetic rehabilitation, but in some cases IANT is the only method allowing an implant-prosthetic rehabilitation with better outcomes predictability and low biological cost for the patient. Reconstructive methods and implantoprosthetic strategies for the edentulous mandibula in Cawood and Howell classes V and VI are different, including short implants, regenerative techniques, autologous, homologous, or heterologous inlay or onlay bone grafts, and osteodistraction. However, each of these methods is connected with a certain amount of risks.
The short implants have a success rate higher than 90% after a 5-year follow-up [11, 17–19]. The problem involves the crown to implant ratio that makes the lever very unfavorable and is responsible for 45% of total stress on the bone cortex [20]. IANT would limit this problem by allowing the insertion of longer implants, but the risk of injuring the IAN makes this method unadvisable if the possibility of inserting short implants exists.
Atrophic jaw regenerative techniques, especially for what concerns vertical dimensions, have a slightly lower success rate than IANT, depending on the reference source and the method and material used, and results are not predictable. Although contextual insertion of implants is described in the literature, such implants are not possible in Cawood and Howell classes V and VI because not enough bone exists to give satisfactory stability to the fixtures. In such cases, implant surgery should be postponed [21–23].
Inlay bone graft techniques have been successfully used in many cases, but this technique is difficult to use for class V cases and almost impossible for class VI cases because the bone cannot be cut without damaging the IAN. This method always requires a second surgery for implant placement. The outcomes of onlay graft methods are not predictable, and the success rate is very low. These methods also require a second surgery for fixtures insertion [24, 25].
Distraction osteogenesis received much attention in the early 2000s but more recently has been gradually abandoned due to its intrinsic unpredictability. Distraction osteogenesis cannot be used in Cawood and Howell class VI cases for the same reasons explained above [26–29].
If an IANT is performed, fixtures can be inserted as a single-step surgery. The implant survival after IANT is good and achieved in up to 90% of the studies considered.
The survival and success rates of implants in the native jawbone after IANT are much higher than the success rate after grafts because the posterior segments of the atrophic mandible lack sufficient numbers of osteogenic cells and microvessels, making it difficult for the grafts to survive [30]. As for our results IANT has shown to be effective method for the rehabilitation of Cawood and Howell class IV, V, or VI in highly motivated patients who desire a predictable outcome in the shortest time possible [31–34]; it has not shown a high complication rate (2.8%) case of anesthesia and 5 (14.3%) cases of transient hypoesthesia, compared to the aforementioned techniques.
6. Conclusion
Although IANT has significant risks, including loss of nerve function, there are some clinical conditions in which it remains the only possible method for implantoprosthetic rehabilitation of the jaw.
According to our experience, if IANT is performed with the correct precautions and the appropriate instruments it is a safe procedure that generates very good results with minimum risks of injuring the neurovascular function.
In our study it has shown little amount of complications, similar to those connected with other techniques considered to be “safer.”
It is our opinion that IANT should be considered in the following cases:
class IV, V, or VI of Cawood and Howell with extrusion of the antagonist tooth and reduced prosthetic free space;
class V or VI of Cawood and Howell with presence of interforaminal teeth (patients not candidates for interforaminal implantoprosthetic methods);
class V or VI of Cawood and Howell if patient desires a fast implantoprosthetic rehabilitation with predictable outcomes.
To our knowledge this is the only paper in which PZ and RB are compared; both of these techniques have advantages and disadvantages but it seems that the use of both these techniques lowers the amount of complicances and speeds the surgical procedure.
Abbreviations
- IAN:
Inferior alveolar nerve
- IANT:
Inferior alveolar nerve transposition
- RB:
Rotary burr
- PZ:
Piezosurgery.
Conflict of Interests
The authors declare that they have no conflict of interests/competing interest and that they have not received any financial support.
References
- 1.Alling CC. Lateral repositioning of inferior alveolar neurovascular bundle. Journal of Oral Surgery. 1977;35(5, article 419) [PubMed] [Google Scholar]
- 2.Fitzpatrick B. Total osteotomy of the mandibular alveolus in reconstruction of the occlusion. Oral Surgery, Oral Medicine, and Oral Pathology. 1977;44(3):336–346. doi: 10.1016/0030-4220(77)90400-5. [DOI] [PubMed] [Google Scholar]
- 3.Becelli R, Renzi G, Carboni A, Cerulli G, Gasparini G. Inferior alveolar nerve impairment after mandibular sagittal split osteotomy: an analysis of spontaneous recovery patterns observed in 60 patients. Journal of Craniofacial Surgery. 2002;13(2):315–320. doi: 10.1097/00001665-200203000-00027. [DOI] [PubMed] [Google Scholar]
- 4.Cawood JI, Howell RA. A classification of the edentulous jaws. International Journal of Oral & Maxillofacial Surgery. 1988;17(4):232–236. doi: 10.1016/s0901-5027(88)80047-x. [DOI] [PubMed] [Google Scholar]
- 5.Apostolakis D, Brown JE. The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and a recommendation for interforaminal implant installation based on cone beam CT imaging. Clinical Oral Implants Research. 2012;23(9):1022–1030. doi: 10.1111/j.1600-0501.2011.02261.x. [DOI] [PubMed] [Google Scholar]
- 6.Kaya Y, Sencimen M, Sahin S, Okcu KM, Doğan N, Bahcecitapar M. Retrospective radiographic evaluation of the anterior loop of the mental nerve: Comparison between panoramic radiography and spiral computerized tomography. International Journal of Oral & Maxillofacial Implants. 2008;23(5):919–925. [PubMed] [Google Scholar]
- 7.Rosenquist B. Fixture placement posterior to the mental foramen with transpositioning of the inferior alveolar nerve. The International Journal of Oral & Maxillofacial Implants. 1992;7(1):45–50. [PubMed] [Google Scholar]
- 8.Smiler DG. Repositioning the inferior alveolar nerve for placement of endosseous implants: technical note. The International Journal of Oral & Maxillofacial Implants. 1993;8(2):145–150. [PubMed] [Google Scholar]
- 9.Oh W-S, Roumanas ED, Beumer J., III Mandibular fracture in conjunction with bicortical penetration, using wide-diameter endosseous dental implants. Journal of Prosthodontics. 2010;19(8):625–629. doi: 10.1111/j.1532-849X.2010.00646.x. [DOI] [PubMed] [Google Scholar]
- 10.Kan JY, Lozada JL, Boyne PJ, Goodacre CJ, Rungcharassaeng K. Mandibular fracture after endosseous implant placement in conjunction with inferior alveolar nerve transposition: a patient treatment report. The International Journal of Oral & Maxillofacial Implants. 1997;12(5):655–659. [PubMed] [Google Scholar]
- 11.Chrcanovic BR, Custódio ALN. Inferior alveolar nerve lateral transposition. Oral and Maxillofacial Surgery. 2009;13(4):213–219. doi: 10.1007/s10006-009-0175-3. [DOI] [PubMed] [Google Scholar]
- 12.Díaz JOF, Gías LN. Rehabilitation of edentulous posterior atrophic mandible: inferior alveolar nerve lateralization by piezotome and immediate implant placement. International Journal of Oral & Maxillofacial Surgery. 2013;42(4):521–526. doi: 10.1016/j.ijom.2012.10.015. [DOI] [PubMed] [Google Scholar]
- 13.Suzuki D, Bassi AP, Lee HJ, et al. Inferior alveolar nerve lateralization and implant placement in atrophic posterior mandible. The Journal of Craniofacial Surgery. 23(4):e347–e349. doi: 10.1097/SCS.0b013e31825655d1. [DOI] [PubMed] [Google Scholar]
- 14.Hashemi HM. Neurosensory function following mandibular nerve lateralization for placement of implants. International Journal of Oral & Maxillofacial Surgery. 2010;39(5):452–456. doi: 10.1016/j.ijom.2010.02.003. [DOI] [PubMed] [Google Scholar]
- 15.Metzger MC, Bormann KH, Schoen R, Gellrich NC, Schmelzeisen R. Inferior alveolar nerve transposition–an in vitro comparison between piezosurgery and conventional bur use. The Journal of Oral Implantology. 2006;32(1):19–25. doi: 10.1563/1548-1336(2006)32[19:IANTIV]2.0.CO;2. [DOI] [PubMed] [Google Scholar]
- 16.Kan JY, Lozada JL, Goodacre CJ, Davis WH, Hanisch O. Endosseous implant placement in conjunction with inferior alveolar nerve transposition: an evaluation of neurosensory disturbance. International Journal of Oral & Maxillofacial Surgery. 1997;12(4):463–471. [PubMed] [Google Scholar]
- 17.Greenstein G, Tarnow D. The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review. Journal of Periodontology. 2006;77(12):1933–1943. doi: 10.1902/jop.2006.060197. [DOI] [PubMed] [Google Scholar]
- 18.Akça K, Iplikcioğlu H. Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism. Journal of Oral Rehabilitation. 2002;29(4):350–356. doi: 10.1046/j.1365-2842.2002.00872.x. [DOI] [PubMed] [Google Scholar]
- 19.Monje A, Chan HL, Fu JH, Suarez F, Galindo-Moreno P, Wang HL. Are short dental implants (<10 mm) effective? A meta-analysis on prospective clinical trials. Journal of Periodontology. 2013;84(7):895–904. doi: 10.1902/jop.2012.120328. [DOI] [PubMed] [Google Scholar]
- 20.Lops D, Bressan E, Pisoni G, Cea N, Corazza B, Romeo E. Short implants in partially edentuolous maxillae and mandibles: a 10 to 20 years retrospective evaluation. International Journal of Dentistry. 2012;2012:8 pages. doi: 10.1155/2012/351793.351793 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Sotto-Maior BS, Senna PM, da Silva WJ, Rocha EP, Del Bel Cury AA. Influence of crown-to-implant ratio, retention system, restorative material, and occlusal loading on stress concentrations in single short implants. The International Journal of Oral & Maxillofacial Implants. 2012;27(3):e13–e18. [PubMed] [Google Scholar]
- 22.Chen ST, Beagle J, Jensen SS, Chiapasco M, Darby I. Consensus statements and recommended clinical procedures regarding surgical techniques. The International Journal of Oral & Maxillofacial Implants. 2009;24:272–278. [PubMed] [Google Scholar]
- 23.Chiapasco M, Casentini P, Zaniboni M. Bone augmentation procedures in implant dentistry. The International Journal of Oral & Maxillofacial Implants. 2009;24:237–259. [PubMed] [Google Scholar]
- 24.Clementini M, Morlupi A, Canullo L, Agrestini C, Barlattani A. Success rate of dental implants inserted in horizontal and vertical guided bone regenerated areas: a systematic review. International Journal of Oral & Maxillofacial Surgery. 2012;41(7):847–852. doi: 10.1016/j.ijom.2012.03.016. [DOI] [PubMed] [Google Scholar]
- 25.Felice P, Pistilli R, Lizio G, Pellegrino G, Nisii A, Marchetti C. Inlay versus onlay iliac bone grafting in atrophic posterior mandible: a prospective controlled clinical trial for the comparison of two techniques. Clinical Implant Dentistry and Related Research. 2009;11, supplement s1:e69–e82. doi: 10.1111/j.1708-8208.2009.00212.x. [DOI] [PubMed] [Google Scholar]
- 26.Block MS, Haggerty CJ. Interpositional osteotomy for posterior mandible ridge augmentation. International Journal of Oral & Maxillofacial Surgery. 2009;67(11):31–39. doi: 10.1016/j.joms.2009.07.008. [DOI] [PubMed] [Google Scholar]
- 27.Bianchi A, Felice P, Lizio G, Marchetti C. Alveolar distraction osteogenesis versus inlay bone grafting in posterior mandibular atrophy: a prospective study. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology. 2008;105(3):282–292. doi: 10.1016/j.tripleo.2007.07.009. [DOI] [PubMed] [Google Scholar]
- 28.Chiapasco M, Zaniboni M, Rimondini L. Autogenous onlay bone grafts vs. alveolar distraction osteogenesis for the correction of vertically deficient edentulous ridges: a 2-4-year prospective study on humans. Clinical Oral Implants Research. 2007;18(4):432–440. doi: 10.1111/j.1600-0501.2007.01351.x. [DOI] [PubMed] [Google Scholar]
- 29.Chiapasco M, Romeo E, Casentini P, Rimondini L. Alveolar distraction osteogenesis vs. vertical guided bone regeneration for the correction of vertically deficient edentulous ridges: a 1-3-year prospective study on humans. Clinical Oral Implants Research. 2004;15(1):82–95. doi: 10.1111/j.1600-0501.2004.00999.x. [DOI] [PubMed] [Google Scholar]
- 30.Uckan S, Veziroglu F, Dayangac E. Alveolar distraction osteogenesis versus autogenous onlay bone grafting for alveolar ridge augmentation: technique, complications, and implant survival rates. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology. 2008;106(4):511–515. doi: 10.1016/j.tripleo.2008.03.011. [DOI] [PubMed] [Google Scholar]
- 31.Polini F, Robiony M, Sembronio S, Costa F, Politi M. Bifunctional sculpturing of the bone graft for 3-dimensional augmentation of the atrophic posterior mandible. Journal of Oral and Maxillofacial Surgery. 2009;67(1):174–177. doi: 10.1016/j.joms.2007.06.646. [DOI] [PubMed] [Google Scholar]
- 32.Ferrigno N, Laureti M, Fanali S. Inferior alveolar nerve transposition in conjunction with implant placement. The International Journal of Oral & Maxillofacial Implants. 2005;20(4):610–620. [PubMed] [Google Scholar]
- 33.Hori M, Sato T, Kaneko K, et al. Neurosensory function and implant survival rate following implant placement with nerve transpositioning: a case study. Journal of Oral Science. 2001;43(2):139–144. doi: 10.2334/josnusd.43.139. [DOI] [PubMed] [Google Scholar]
- 34.Lorean A, Kablan F, Mazor Z, et al. Inferior alveolar nerve transposition and reposition for dental implant placement in edentulous or partially edentulous mandibles: a multicenter retrospective study. International Journal of Oral & Maxillofacial Surgery. 2013;42(5):656–659. doi: 10.1016/j.ijom.2013.01.020. [DOI] [PubMed] [Google Scholar]