Skip to main content
Journal of Neurophysiology logoLink to Journal of Neurophysiology
. 2014 May 7;112(3):543–551. doi: 10.1152/jn.00108.2014

Characterization of motor units in behaving adult mice shows a wide primary range

Laura K Ritter 1, Matthew C Tresch 1,2,3, C J Heckman 2,3,4, Marin Manuel 5, Vicki M Tysseling 2,4,
PMCID: PMC4122694  PMID: 24805075

Abstract

The mouse is essential for genetic studies of motor function in both normal and pathological states. Thus it is important to consider whether the structure of motor output from the mouse is in fact analogous to that recorded in other animals. There is a striking difference in the basic electrical properties of mouse motoneurons compared with those in rats, cats, and humans. The firing evoked by injected currents produces a unique frequency-current (F-I) function that emphasizes recruitment of motor units at their maximum force. These F-I functions, however, were measured in anesthetized preparations that lacked two key components of normal synaptic input: high levels of synaptic noise and neuromodulatory inputs. Recent studies suggest that the alterations in the F-I function due to these two components are essential for recreating firing behavior of motor units in human subjects. In this study we provide the first data on firing patterns of motor units in the awake mouse, focusing on steady output in quiet stance. The resulting firing patterns did not match the predictions from the mouse F-I behaviors but instead revealed rate modulation across a remarkably wide range (10–60 Hz). The low end of the firing range may be due to changes in the F-I relation induced by synaptic noise and neuromodulatory inputs. The high end of the range may indicate that, unlike other species, quiet standing in the mouse involves recruitment of relatively fast-twitch motor units.

Keywords: motor unit recordings, mouse, electromyographic recordings, motoneuron


the motor unit, consisting of a motoneuron and the muscle fibers it innervates, serves as the link between the nervous system and the musculoskeletal system, converting neural inputs into the forces required to produce movement. The forces exerted by muscles are determined by both the number of motor units recruited and the frequency at which these recruited units fire (Adrian and Bronk 1929; Clark et al. 1993; Duchateau and Enoka 2011). Recording of motor unit activity in humans suggests that both mechanisms, motor unit recruitment and frequency modulation, are used by motor units to grade the force produced by muscle (Heckman and Enoka 2012).

A recent study, however, suggested that mice might use a strategy of force recruitment very different from that observed in humans (Manuel and Heckman 2011). Using intracellular recordings of motoneurons in anesthetized mice in vivo, they showed that motoneuron firing rates jumped to very high levels (>30 Hz) as input current was graded. These rates were near to full tetanic force for motor units, such that further increases in firing rates by the motoneuron produced only minimal additional force. Low firing rates could only be observed within a “subprimary” range, in which firing rates of motor units were highly variable and not well related to the input current. These observations suggested that, in contrast to humans, mice might primarily rely on motor unit recruitment rather than frequency modulation for grading force output.

Although those experiments were performed in vivo without isolating spinal circuitry from descending systems, the use of anesthetics in those experiments might have significantly altered the processing of inputs by motoneurons. Anesthesia suppresses the neuromodulatory input from the brain stem that controls motoneuron intrinsic excitability and is essential for normal input-output processing (Heckman and Enoka 2012). In addition, normal synaptic input is much noisier than the injected currents used to generate firing by Manuel et al. (Manuel and Heckman 2011).

To evaluate the role of rate modulation in motor output during natural behaviors in mice, we developed techniques for recording the activity of motor units in mice during natural behavior. Although motor unit activity has been recorded in several animal models (Gorassini et al. 2000; Hoffer et al. 1987; O'Donovan et al. 1983), no studies have recorded motor units in behaving mice, presumably because of their small size. The ability to record motor unit activity during behavior in mice would be broadly significant because of the increasing use of mice as models of neurodegenerative diseases and for studying the functional consequences of various genetic manipulations. Using modifications of existing techniques for motor unit recordings in other species, we show here that it is possible to make reliable recordings of single motor units during quiescent behaviors in awake mice. These techniques allowed us to examine the strategies for graded motor output in mice. We show rate modulation across a wide range of firing rates and conclude that the strategies suggested by intracellular motoneuron recordings were not observed in intact, unanesthetized mice during natural behavior.

Some of these results were previously published in an abstract at the 2012 Society for Neuroscience conference. (Tysseling et al. 2012).

MATERIALS AND METHODS

Single-motor unit and gross electromyographic (EMG) recordings were performed in 15 female CD-1 mice aged between 65 and 80 days. Fine-wire recording electrodes were percutaneously implanted into the lateral gastrocnemius (LG) muscle of either the left or right hindlimb, and mice were allowed to behave naturally during all recordings. This acute, percutaneous design worked very well for quantifying motor unit activity in quiet stance. The method is fast, does not require extensive surgeries, and is virtually pain-free for the mice. Because we focused on quiet stance, very few motor units were active at one time, giving us good isolation of single units.

Although recordings were performed in all 15 mice, good motor unit activity meeting our selection criteria (detailed below) was only found in 8 of the 15 mice. From those 8 mice, 28 different single motor units were analyzed, with 13 of those units having accompanying gross EMG data. All animal procedures were approved by the Northwestern University Animal Care and Usage Committee.

Electrode design.

Single-motor unit and gross EMG recording electrodes were constructed with dual-core nylon-coated nickel/chromium wire in a duplex configuration (California Fine Wire, material no. 100189) for differential recordings. The diameter of each wire was 25 μm for single-motor unit recordings and 50 μm for the gross EMG electrodes. Ground electrodes were constructed with single-core stainless steel 0.002-in.-diameter wire with a Teflon coating (A-M Systems, product no. 790700) (Fig. 1).

Fig. 1.

Fig. 1.

Schemata of single-motor unit and gross EMG recording electrode designs. A: diagram of the recording surface for the single-motor unit recording electrode showing the configuration of the dual-core wire. Wire was cut to achieve the smallest possible recording surface, each measuring 25 μm. B: diagram of the design for the gross EMG recording electrode. The 2 recording surfaces were each 50 μm in diameter by 0.5 mm in length and were separated by 2 mm.

To construct the single-motor unit recording electrodes, an ∼12-in. segment of the 25-μm-diameter dual-core wire was cut and threaded through a 30½-gauge hypodermic needle. With a sharp scalpel blade, the recording end of the electrode was cut perpendicular to the wire to achieve the smallest possible differential recording surface and thus the best selectivity (Fig. 1A). The recording end of the wire was then bent to create a small hook ∼2 mm long. This hook secured the electrodes within the muscle. The opposite end of the wire was then carefully split with a scalpel to separate the two wires, making sure to maintain insulation around each wire. The ends were then stripped roughly 2 mm and soldered to pins for connecting to the amplifier. Finally, impedance testing was performed to ensure that a good connection had been made between the wire and the pins. Impedances for each wire were typically between 0.6 and 1.7 MΩ.

To construct the gross EMG recording electrodes, an ∼12-in. segment of the 50-μm-diameter dual-core wire was cut and threaded through a 27½-gauge hypodermic needle. With a scalpel blade, the two wires were cut and the insulation was stripped so that there were two 0.5-mm recording surfaces roughly 2 mm apart (Fig. 1B). Both ends were hooked just as with the single-motor unit electrodes to secure the electrode in the muscle. The opposite end of the dual-core wire was separated and soldered to pins for connecting to the amplifiers. The impedances for gross EMG electrodes were typically between 30 and 150 kΩ.

Ground electrodes were made by cutting ∼12 in. of the single-core stainless steel wire that was then threaded through a 30½-gauge hypodermic needle. At the recording end of the electrode, insulation was carefully stripped with a sharp scalpel blade to expose roughly 0.5 in. of wire. This exposed wire was then bent to form a hook.

Implantation and data collection.

For electrode implantation during experiments, mice were anesthetized with isoflurane (2–3%) and placed on a heating pad. The area of implantation on the hindlimb was shaved, and both the fine-wire gross and single-motor unit recording electrodes were percutaneously implanted in LG. The single-motor unit electrode was inserted such that the line connecting the two recording surfaces would be oriented perpendicular to the direction of the muscle fibers (Andreassen and Rosenfalck 1978). The gross electrode was inserted prior to the single-motor unit electrode in order to minimize possible damage to the finer, more fragile single-motor unit electrode. The ground electrode was implanted subcutaneously on the back. All hypodermic insertion needles were pulled back and secured at the far end of the electrode with a small amount of tape. Recordings were taken once the animal had fully awakened and was mobile, at least 5–10 min after discontinuation of isoflurane, and continued until either the electrode was displaced by the animal or sufficient data were collected (typically 15–30 min).

Animals were placed in a small closed-off area. A Mouse Igloo (Bio-Serv) enclosure was placed in the area to encourage the animals to rest quietly during recordings. We found that isolation of motor units was very difficult during vigorous behaviors, such as locomotion, because of interference with other motor units recorded on the same electrode. We therefore focused on motor unit activity during postural maintenance during rest. We recorded periods of spontaneous activity in single motor units during this postural maintenance. In some cases when units were not well isolated or when we had recorded from a particular unit for an extended period of time, we gently tugged the implanted electrode in order to move the electrode within the muscle.

Signals from both the single-motor unit electrode and the gross EMG electrode were recorded differentially. Single-motor unit activity passed first through a differential amplifier (World Precision Instruments, DAM-50-H) placed close to the animal that amplified 100× and filtered between 300 Hz and 10 kHz. Single-motor unit activity was then passed through a second differential amplifier (A-M Systems, 1700), where it was again amplified 100× and filtered between 100 Hz and 5 kHz. Gross EMG was amplified (A-M Systems, 1700; 10,000×), filtered between 100 Hz and 5 kHz, and stored on a single channel. Both the single-motor unit and gross EMG signals were digitized to the computer (PCI-6229, 16-bit, National Instruments) and sampled at 20 kHz. National Instruments LabVIEW software was used to visualize, record, and store all EMG signals. Recordings were taken in roughly 2-min segments, with up to 10 recordings done per session for an individual animal.

Data analysis.

All data analysis was performed with custom-designed routines in MATLAB. The single-motor unit activity was manually screened for areas of at least 5 s of continuous motor unit activity with good isolation. Candidate waveforms were identified by voltage threshold crossings, and the extracted waveforms were visualized. The waveforms of potentially well-isolated units were then characterized according to several features so that clustering could be performed. Clustering was performed over windows of time ranging anywhere from 3 to 50 s, with typical windows between 5 and 10 s long. The duration of the window was chosen in order to be able to continuously track the activity of single units over time, even in the presence of slow drifts in the shape of the recorded waveform. Windows overlapped by 0.5–1 s to ensure that all instances of a unit were accounted for. Single motor units were first clustered on the basis of maximum and minimum voltages. Initial clustering was further refined by examining individual waveforms, interspike intervals (ISIs), and other waveform features such as time to largest peak, time to largest valley, and the first and second principal components. Any individual waveforms that were ambiguously identified on the basis of features were examined subsequently by the experimenter. Once all instances of a unit in a given window of data were found and clustered, the individual clustering windows described above were combined into one consolidated stretch of data, giving the spike times for a single recorded motor unit. In most cases, only a single, well-isolated motor unit was identified from each recording in order to avoid confusion in identifying waveforms during near-synchronous activity.

In addition to the close inspection of isolated waveforms during the process of clustering waveforms described above, we also performed a quantitative analysis of clustering quality. For each window used to cluster action potentials, we calculated the Lratio as described elsewhere (Schmitzer-Torbert et al. 2005; Schmitzer-Torbert and Redish 2004). Briefly, the Lratio assesses cluster separation as the probability that each unclustered spike should actually be included in a given cluster. Lratio values below 0.05 have been interpreted as indicating good cluster separation in previous studies (Anikeeva et al. 2012; Schmitzer-Torbert and Redish 2004). The Lratio value for each window was calculated with the first two principal components of each extracted waveform. In a small number of clustering cases (4) two large but distinguishable units were simultaneously active. In these cases, separation was achieved by individual waveform examination, allowing for the possibility of superpositions of waveforms. Since such superpositions obscure the parameters identified by principal component analysis, for these cases we assessed the quality of cluster separation using minimum and maximum voltages.

To characterize the firing behavior of a motoneuron, we first found the firing rate distribution of each unit. ISIs were calculated and used to find instantaneous firing rates. Average firing frequency for each unit was taken as the average instantaneous firing rate. Any ISI larger than 500 ms was considered a stop in firing and was not included in the calculation of average firing frequency (Hennig and Lomo 1985).

A second analysis of firing frequency was performed to characterize the lowest firing rate at which each motor unit could fire tonically. Periods of firing were first inspected visually to identify periods of at least 5 s over which the firing rate of neurons appeared not to vary substantially. For those units with simultaneous EMG recordings, we also examined EMG activity in the same periods, excluding periods with obvious transient changes in EMG levels. To confirm that the motoneuron firing rate did not change systematically over the identified period, we then calculated the correlation between the motoneuron firing rate and time over the period. Only periods for which there was no significant correlation (P < 0.05) were included in further analyses. For each unit, we performed the above analysis repeatedly, searching for the lowest tonic firing rate observed over a 5-s period. It is unlikely, however, that we were able to catch, in a given recording session, the absolute lowest rate possible for a motoneuron. Our analysis therefore most likely yielded an overestimation of the lowest firing rate. To examine whether motoneuron firing variability changed with firing rate, we also found the highest tonic firing frequency over a 5-s window, using the procedure and criteria just described. To guarantee that there was a substantial difference in firing rate between the low- and high-firing rate periods, we only included a high-firing rate period for a unit if the rate was at least one standard deviation (as calculated from the period of lower firing rate) above the low tonic frequency. Because of this condition, units for which a small range of firing rates was observed might not have both a high and a low firing rate. We then calculated the coefficient of variation (CV) in instantaneous firing rate over each 5-s period. The relationship between change in firing rate and CV was then assessed with a two-tailed Student's t-test comparing the CV for high and low firing rates (α = 0.05) and a Pearson correlation coefficient between CV and firing rate (α = 0.05). Of note, we considered that our use of the CV as a measure of firing regularity is potentially flawed because it does not take into consideration the temporal relationship between ISIs. Previous work has tried to deal with this limitation by calculating the differences between consecutive ISIs (ΔISI) and using the interquartile range of the resulting distribution to determine the regularity of motor unit firing (Eken et al. 2008). However, we determined that this technique contained a bias when used across a large range of frequencies (by way of a test using a Poisson random variable) and thus was not applicable for comparing regularity of firing at high versus low frequencies.

Of the 28 units analyzed, 13 had simultaneous gross EMG data. For these 13 units, we analyzed the relationship between gross EMG activity and single-unit firing frequency. Raw gross EMG was high-pass filtered (2nd-order Butterworth, high-pass cutoff 50 Hz) to remove movement artifact and then rectified. Both the average level of gross EMG activity and average single-motor unit firing frequency were calculated over corresponding, nonoverlapping 500-ms windows during periods of tonic activity in unit firing. Correlation between EMGs and unit firing rates was assessed with the Pearson correlation coefficient and a one-tailed Student's t-test with α = 0.05.

Occasionally high-amplitude phasic events were seen in the gross EMG during tonic motor unit firing. Eken et al. reported similar observations in their study of spontaneous EMG activity in conscious unrestrained rats (Eken et al. 2008). They noted that these events were sometimes present at the initiation and termination of motor unit firing and during almost undetectable startle responses and postural adjustments. Although it is difficult during these high-amplitude phasic events to describe system input, they were not excluded from our analysis as these bursts of gross EMG activity help characterize mouse motor units across a range of motor output. Only cases for which we were able to maintain good unit isolation during these transients were included in the analyses described here. We also repeated the analyses between unit firing and EMGs after removing these events and found that the results described here were not substantially altered.

Isolation of single-motor unit waveforms during resting postures in mice.

Figure 2A shows an example of activity in a single LG motor unit recorded along with gross EMG in LG. As can be seen in the figure, this unit was well isolated, with waveform amplitudes much larger than the background noise level and waveforms clearly distinguishable from other units. Note also the tonic firing of this unit across the recording window. Similar periods of tonic activity were used for analyses described below. The good isolation of this unit was confirmed by examination of extracted waveforms (Fig. 2B), showing the consistency of the recorded waveform during this window of activity and its separation from background noise. Figure 2C shows the values of the first two principal components calculated for the waveforms in Fig. 2B, illustrating again the good separation between the identified unit and background noise.

Fig. 2.

Fig. 2.

Example of isolated single-motor unit activity recorded in the awake, behaving mouse. A, top: representative single-motor unit EMG recording over 5 s. Bottom: gross EMG from the same muscle over the same 5-s window. B: overlaid waveforms isolated from the recording shown in Fig. 1A. Red waveforms correspond to the large-amplitude, well-isolated motor unit, while the blue waveforms correspond to other motor units or noise. C: example of clustering performed on the isolated waveforms shown in Fig. 1B. Red dots correspond to the motor unit of interest. Blue dots correspond to other motor units and noise. Lratio = 5.49 × 10−12 for this cluster.

We quantified the isolation of single motor units with the Lratio (see above). The Lratio for the unit illustrated in Fig. 2 was 5.49 × 10−12. The distribution of Lratio observed for the single motor units analyzed in this study is shown in Fig. 3. Note that the Lratio was calculated for each window over which single-unit waveforms were clustered, so an individual unit could contribute multiple Lratio values in this histogram. As seen in the histogram, the majority of clusters obtained had very small Lratio values, confirming that the units analyzed in this study were well-isolated single motor units.

Fig. 3.

Fig. 3.

Single motor units can be consistently recorded in awake mice. This histogram shows the distribution of Lratio values across all clusters for all motor units. The majority of Lratio values fall at or near 0, indicating good cluster isolation.

RESULTS

Mouse motor units display wide range of firing frequencies during behavior.

We obtained tonic firing data from 28 different motor units in the LG muscle of adult mice. Although the mice were free to move during recording sessions, they primarily remained in the enclosure during these recordings. An example of a typical distribution of instantaneous firing rates for a single motor unit observed during behavior is shown in Fig. 4A. The average firing frequency for this motor unit was 21 Hz. Figure 4B shows the average firing frequencies obtained from the 28 motor units. Note that these firing rates were calculated over all periods of activity for each individual motor unit. Figure 4C shows the histogram of these average firing frequencies; motor units are ordered in the figure from lowest to highest average firing frequency (9–68 Hz) to show the entire range of observed firing rates. Note that we observed both units with low firing rates and units with high rates, clearly demonstrating the existence of a broad range of rate modulation with units. Each of the ranges of 10–20 Hz, 20–30 Hz, 30–40 Hz, and 40–50 Hz were well represented in our sample, with one unit <10 Hz and one unit >60 Hz. Further examination of the recordings for this high-firing unit confirmed that it was well isolated throughout the recording. We also observed other units with lower firing rates from the same animal in the same recording session.

Fig. 4.

Fig. 4.

Mouse motor units have a wide distribution of average firing frequencies. A: histogram showing the instantaneous firing rate distribution for a motor unit with a low average firing frequency (21 Hz). B: average firing frequency, ordered from lowest to highest (9–68 Hz), calculated for each of 28 motor units. For each motor unit, the average was calculated across all firing. Bars show SD. C: histogram of average firing frequencies over the same 28 motor units. D: distribution of lowest tonic firing frequencies for each motor unit over a 5-s window. Dashed line indicates 30 Hz, below which motor units are expected to be in the subprimary range. More than half of the motor units had low tonic firing rates below 30 Hz. Motor units are displayed in ascending order of lowest tonic frequency.

Comparison to previously published firing behavior evoked by intracellular current injection.

The range of firing rates observed during quiet standing in the mouse is remarkably wide and appears to exceed that of larger animals (rats, cats, humans; see discussion). The previous intracellular studies showed that the lowest transition frequency from the subprimary to the primary range occurred in the slowest units and was ∼30 Hz (Manuel and Heckman 2011). Because it is likely that quiet standing strongly recruits slow, low-threshold units (see discussion), the wide range of 10–70 Hz would be expected to require utilization of both the subprimary and primary ranges.

In the intracellular studies, the transition to the primary range is associated with a sharp drop in variance (this transition varied with motor unit contraction speed, from a minimum of 30 Hz in the slowest units to a maximum of 70 Hz in the fastest) (Manuel and Heckman 2011). To determine whether a transition in variance occurred in the motor unit firing patterns, we first examined the lowest rate at which the motor units were capable of firing tonically for periods of at least 5 s. In this analysis, 24 of the 28 units had 5 s over which the firing rate did not systematically vary with time (Pearson correlation coefficient between firing rate and time, P > 0.05). Figure 4D shows the range of these lowest tonic firing rates for each unit. The majority of recorded units (14 of 24) were capable of firing at rates lower than 30 Hz (horizontal dashed line), showing that low firing rates were commonly used by mouse motoneurons.

We then examined the relationship between motoneuron firing rate and EMG activity. EMG activity reflects the intensity of a motor command and thus provides an indirect estimate of the overall synaptic input to a motor pool. Gross EMG was recorded simultaneously with single-motor unit firing for 13 units. We found that the firing rate of 8 of the 13 single units had positive correlations to the rectified gross EMG. Two examples of units with positive correlations are shown in Fig. 5. Good correlations could be observed for units with both low (Fig. 5A; almost the full range is <30 Hz) and high (Fig. 5B; mostly >30 Hz) firing rates. No evident transition in the variability of firing was evident in any of the eight units with positive rate vs. EMG correlations. To examine this issue further, we calculated the CV of single-motor unit firing during periods of tonic firing. Consistent with the results shown in Fig. 5, we found no significant correlation between firing rate and variability [neurons with lower tonic firing rates were not associated with higher variability in firing (r = 0.0033, P > 0.05)] (Fig. 6A). We examined this same issue in individual motor units, comparing the variability of firing in a motor unit during its period of lowest tonic firing to the variability of firing during its period of highest tonic firing. We found no tendency for lower firing rates to be associated with higher variability in individual motor units. (r = −0.1115, P > 0.05) (Fig. 6B). Taken together, these results suggest that low firing rates were not associated with the high variance that is characteristic of the subprimary range. Thus the systematic occurrence of low firing rates in quiet standing in the mouse probably involves effects of synaptic noise and neuromodulatory inputs.

Fig. 5.

Fig. 5.

Examples of motor units with positive correlations between firing rate and gross EMG. A: for this motor unit, there is a highly significant correlation (r = 0.83, P < 0.0001) between firing frequency and gross EMG activity, with the unit active over a low range of frequencies. B: as in A, this motor unit shows a highly significant correlation (r = 0.74, P < 0.0001) between firing frequency and gross EMG activity but is active at higher frequencies. Lines represent the best linear fit.

Fig. 6.

Fig. 6.

Variability of motor unit firing at low tonic frequencies vs. high tonic frequencies. A: coefficient of variation (CV) plotted against the lowest tonic firing frequency for each unit (as shown in Fig. 4D). There was no relationship between CV and firing rate, suggesting that lower firing rates were not associated with higher variability. B: comparison of the variability of firing in an individual motor unit during its period of lowest tonic firing to the variability of firing during its period of highest tonic firing. There was no relationship between increased firing rate and a change in CV for individual motor units, again suggesting a lack of relationship between firing rate and variability.

The intracellular study showed that the transition frequency from subprimary to primary range generated ∼90% of maximum force in all motor units (Manuel and Heckman 2011). As a result, this transition frequency varied from 30 to 70 Hz and was tightly correlated with motor unit contraction speed. If the units in the present study were predominantly slow, then units with firing rates above 30–40 Hz would exceed their tetanic maximum. Figure 4B shows that 16 of the 28 units recorded (∼57%) had firing rates that averaged 30 Hz or above and 9 units (∼32%) had average firing rates at 40 Hz or above. Moreover, the standard deviations of the average firing rates in Fig. 4B exceeded 40 Hz in 17 units (∼60%), indicating that well over half the sample of units spent at least a portion of their activity at firing rates that exceed tetanic maximum for slow-twitch motor units. As force generation above tetanic maximum would be energetically inefficient, this result suggests that quiet standing in the mouse involves the recruitment of fast motor units, presumably the fast fatigue-resistant category.

DISCUSSION

This study presents data characterizing the activity of single motor units in conscious freely behaving mice. While motor unit studies have been performed in numerous species to date (Heckman and Enoka 2012), the development of transgenic mouse models of neurodegenerative diseases such as amyotrophic lateral sclerosis (ALS) motivates an increase in motor unit studies in mice (Herron and Miles 2012). Briefly, our findings show rate modulation across a wide range of firing rates that is inconsistent with predictions from previous studies in anesthetized preparations.

Applicability of fine-wire percutaneous electrodes to record single-motor unit activity in mice.

This study used percutaneous electrodes to record single-motor unit activity in mice. The advantage of a percutaneous electrode over an implantable electrode is that minimal surgery and recovery time are required. Additionally, the percutaneous electrode can be adjusted to sample from a different set of muscle fibers, allowing the recording of multiple single motor units with only one insertion. This technique is commonly used to record single-motor unit activity in humans with much success (Duchateau and Enoka 2011). However, there is a considerable difference in the size of mouse versus human muscles; therefore, use of this technique in mice requires careful consideration of the selectivity of the electrodes. Also, the particular quiet stance behavior targeted in this study is well suited to the percutaneous technique since very few motor units are active at once. As evidenced by waveform inspection (e.g., Fig. 2) and by the low Lratio values (Figs. 2 and 3), we were able to obtain well-isolated single-motor unit recordings using this approach.

We note that there may be some limitations to the types of muscles in which this technique can be applied for the mouse. Without surgically visualizing a muscle, it is more difficult to determine that the electrode has been successfully implanted. In the experiments described here, we examined units in a large muscle close to the skin surface, in order to minimize these concerns. We confirmed the appropriate placement of our electrodes in pilot experiments in cadavers, confirming that electrodes were placed in the targeted muscle. While it would be more difficult to apply this technique to smaller and more deeply located muscles, for studies of larger muscles it is a convenient alternative to chronic surgical techniques.

Mouse motor units in comparison to other species.

In our study of mouse motor units during quiet standing, we observed a wider range of tonic firing frequencies (average values ranged from 9 to 68 Hz) than seen in other species during similar behavior. Eken (1998) reported median firing frequencies in the range of 16–25 Hz for tonically active motor units in the soleus muscle of rats. This was similar to results seen by Hennig et al. (Hennig and Lomo 1985). Higher rates have been seen in the LG muscle of the rat but only during locomotion (Gorassini et al. 1999). Cats during locomotion have been reported to have motor unit firing of the anterior thigh only in the range of 10–30 Hz (Hoffer et al. 1987). During slow ramp contractions, human motor units from tibialis anterior, the hand, and soleus were found to start firing at as low as 5 Hz but reached maximums of around only 30 Hz (Desmedt and Godaux 1977; Moritz et al. 2005; Oya et al. 2009). In ballistic contractions, human motor units were able to reach initially high rates of 60–120 Hz, but such high rates were not sustained. During slow increases and decreases in force, human motor units from tibialis anterior, soleus, and biceps brachii muscles vary only from 8 to 15 Hz (Gorassini et al. 2002; Mottram et al. 2005). Similar to the results from slow ramp contractions, low-threshold single motor units in human short toe extensors during walking at normal speeds were found to only have firing frequencies in the range of 12–25 Hz (Grimby 1984). It is clear that there are differences between mouse and human motor unit recordings. Nonetheless, we anticipate that the relative changes in mouse and human motor unit firing will be reasonably similar in disease states like spinal injury and ALS, but this is yet untested. In addition, understanding the characteristic of mouse motor units will allow the power of the genetic approaches available in the mouse to be brought to bear on understanding the distortions of these patterns.

Our recordings came from LG, a muscle containing a heterogeneous mix of muscle fiber types. However, it is likely that we only observed activity in fatigue-resistant units, since we limited our recordings to quiet stance and focused on tonic firing of units. Hennig et al. documented that FF-type fibers in the extensor digitorum longus were only active for ∼1–2 s (Hennig and Lomo 1985), and Eken et al. noted only one abnormally high-firing motor unit in the soleus (∼47 Hz) that was active for >8 s at a time (Eken 1998). Our high-frequency motor units were active for much longer than 8 s; therefore, the prolonged motor unit firing that we observed likely did not come from highly fatigable fast motor units.

Comparison of conscious behavioral studies to intracellular experiments.

Previous studies in mice have focused primarily on intracellular recordings of motoneurons (Alstermark and Ogawa 2004; Carp et al. 2008; Iglesias et al. 2011; Manuel and Heckman 2012; Meehan et al. 2010b) or decerebrate preparations (Nakanishi and Whelan 2012), which provide valuable information but are limited by the lack of information from natural behaviors. In our study, quiet stance produced steady motor unit firing rates that varied over a remarkably wide range, from <10 to >60 Hz. Broadly speaking, the wide range of firing rates seen in quiet stance is consistent with the wide range of firing rates generated by current injection in low-threshold motoneurons during intracellular recordings (Manuel and Heckman 2011). The intracellular recordings showed that low-threshold motoneurons that innervate slow fibers generate near-tetanic forces at 30–40 Hz (Manuel and Heckman 2011). Thus units at the upper end of the firing range in our data were either at supratetanic levels where rate modulation has little impact or they were fast fatigue-resistant units, which probably generate near-tetanic forces at ∼40–60 Hz (Manuel and Heckman 2011). Based on Burke's classification of S (slow), FR (fast fatigue resistant), and FF (fast fatigable) (Burke 1981), it seems reasonable to suppose that quiet standing in the mouse involves not only S but also significant FR recruitment. Presumably the higher rates are not due to recruitment of FF units, which fatigue easily (Clark et al. 1993). Perhaps the relatively fast motor behavior of this small animal or the faster metabolism from the higher surface area to body volume requires more frequent activation of fast units than in larger animals. It would be interesting to study smaller animals and test whether this difference continues, but our experience suggests that we are near our technical limit for this method of recording. Another potential explanation for such a wide range of rates would be abnormal motor unit recruitment due to stress. It seems unlikely that the mice are under much stress as they are acclimatized to the environment and to handling, and also have enclosures during testing. Also, recent work indicates that discharge rate of motor units is not effected by stress (Stephenson and Maluf 2010).

Although transition from the subprimary range to the primary range in the intracellular data is clearly associated with a marked reduction in variance of firing, no such transition in variance was observed from low to high motor unit firing rates during conscious behavior. The average CV in our data was 0.35; in the study of Manuel and Heckman the CV was also ∼0.3 in the subprimary range but in the primary range only 0.12 (unpublished data). One explanation for this lack of transition in variance is that the intracellular recordings were obtained in anesthetized adult mice. This state lacks neuromodulatory inputs both from the brain stem and within the spinal cord that likely characterize normal motor behaviors and synaptic noise (Heckman and Enoka 2012). An important effect of neuromodulatory input, especially that mediated by the serotonergic and noradrenergic brain stem systems, is to facilitate persistent inward currents (PICs). It is likely that PICs occur in mouse motoneurons (Meehan et al. 2010a) just as in cats and rats (Bennett et al. 2001; Hamm et al. 2010; Lee and Heckman 1999). The Na component of the PIC (NaPIC) plays a fundamental role in spike generation (Kuo et al. 2006; Lee and Heckman 1999; Li and Bennett 2003). In fact, the presence of the subprimary range in the anesthetized state may reflect an abnormally low-amplitude NaPIC (Iglesias et al. 2011; Manuel et al. 2012). A larger NaPIC that would occur with normal neuromodulation in the intact mouse may extend the primary range downward in the intracellular experiments and altogether avoid a subprimary range. In addition, the presence of synaptic noise in normal behavior would significantly affect variability through the firing range and may further obscure the transition between primary and subprimary ranges. Thus the presence of a wide range of firing rates without any transition from high to low variability in our intact mouse data could readily be accounted for by both noise and neuromodulatory input in the synaptic drive.

In summary, the wide range of firing seen in mouse LG motor units during quiet stance probably has two basic mechanisms. The low frequencies arise from PICs and neuromodulation, potentially extending the primary range downward. The high frequencies may be accounted for by recruitment of FR motor units. The implications of this wide firing range for mouse models of disease states like ALS and spinal injury are not as yet clear, requiring motor unit measurements in a wide range of disease models.

GRANTS

This work was supported by a Craig H. Neilsen Foundation postdoctoral fellowship (V. M. Tysseling), by National Institutes of Health (NIH) Grant R01 AR-053608 (M. C. Tresch), and by NIH Grant NS-077863 (C. J. Heckman).

DISCLOSURES

No conflicts of interest, financial or otherwise, are declared by the author(s).

AUTHOR CONTRIBUTIONS

Author contributions: L.K.R., M.C.T., C.J.H., and V.M.T. conception and design of research; L.K.R., M.C.T., and V.M.T. performed experiments; L.K.R. and V.M.T. analyzed data; L.K.R., M.C.T., C.J.H., M.M., and V.M.T. interpreted results of experiments; L.K.R. and V.M.T. prepared figures; L.K.R. drafted manuscript; L.K.R., M.C.T., C.J.H., M.M., and V.M.T. edited and revised manuscript; L.K.R., M.C.T., C.J.H., M.M., and V.M.T. approved final version of manuscript.

REFERENCES

  1. Adrian ED, Bronk DW. The discharge of impulses in motor nerve fibres. Part II. The frequency of discharge in reflex and voluntary contractions. J Physiol 67: i3–151, 1929 [PMC free article] [PubMed] [Google Scholar]
  2. Alstermark B, Ogawa J. In vivo recordings of bulbospinal excitation in adult mouse forelimb motoneurons. J Neurophysiol 92: 1958–1962, 2004 [DOI] [PubMed] [Google Scholar]
  3. Andreassen S, Rosenfalck A. Recording from a single motor unit during strong effort. IEEE Trans Biomed Eng 25: 501–508, 1978 [DOI] [PubMed] [Google Scholar]
  4. Anikeeva P, Andalman AS, Witten I, Warden M, Goshen I, Grosenick L, Gunaydin LA, Frank LM, Deisseroth K. Optetrode: a multichannel readout for optogenetic control in freely moving mice. Nat Neurosci 15: 163–170, 2012 [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Bennett DJ, Li Y, Siu M. Plateau potentials in sacrocaudal motoneurons of chronic spinal rats, recorded in vitro. J Neurophysiol 86: 1955–1971, 2001 [DOI] [PubMed] [Google Scholar]
  6. Burke R. Motor units: anatomy, physiology, and functional organization. In: Handbook of Physiology. The Nervous System. Motor Control. Bethesda, MD: Am Physiol Soc, 1981, sect. 1, vol. II, p. 345–422 [Google Scholar]
  7. Carp JS, Tennissen AM, Mongeluzi DL, Dudek CJ, Chen XY, Wolpaw JR. An in vitro protocol for recording from spinal motoneurons of adult rats. J Neurophysiol 100: 474–481, 2008 [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Clark BD, Dacko SM, Cope TC. Cutaneous stimulation fails to alter motor unit recruitment in the decerebrate cat. J Neurophysiol 70: 1433–1439, 1993 [DOI] [PubMed] [Google Scholar]
  9. Desmedt JE, Godaux E. Ballistic contractions in man: characteristic recruitment pattern of single motor units of the tibialis anterior muscle. J Physiol 264: 673–693, 1977 [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Duchateau J, Enoka RM. Human motor unit recordings: origins and insight into the integrated motor system. Brain Res 1409: 42–61, 2011 [DOI] [PubMed] [Google Scholar]
  11. Eken T. Spontaneous electromyographic activity in adult rat soleus muscle. J Neurophysiol 80: 365–376, 1998 [DOI] [PubMed] [Google Scholar]
  12. Eken T, Elder GC, Lomo T. Development of tonic firing behavior in rat soleus muscle. J Neurophysiol 99: 1899–1905, 2008 [DOI] [PubMed] [Google Scholar]
  13. Gorassini M, Bennett DJ, Kiehn O, Eken T, Hultborn H. Activation patterns of hindlimb motor units in the awake rat and their relation to motoneuron intrinsic properties. J Neurophysiol 82: 709–717, 1999 [DOI] [PubMed] [Google Scholar]
  14. Gorassini M, Eken T, Bennett DJ, Kiehn O, Hultborn H. Activity of hindlimb motor units during locomotion in the conscious rat. J Neurophysiol 83: 2002–2011, 2000 [DOI] [PubMed] [Google Scholar]
  15. Gorassini M, Yang JF, Siu M, Bennett DJ. Intrinsic activation of human motoneurons: possible contribution to motor unit excitation. J Neurophysiol 87: 1850–1858, 2002 [DOI] [PubMed] [Google Scholar]
  16. Grimby L. Firing properties of single human motor units during locomotion. J Physiol 346: 195–202, 1984 [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Hamm TM, Turkin VV, Bandekar NK, O'Neill D, Jung R. Persistent currents and discharge patterns in rat hindlimb motoneurons. J Neurophysiol 104: 1566–1577, 2010 [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Heckman CJ, Enoka RM. Motor unit. Compr Physiol 2: 2629–2682, 2012 [DOI] [PubMed] [Google Scholar]
  19. Hennig R, Lomo T. Firing patterns of motor units in normal rats. Nature 314: 164–166, 1985 [DOI] [PubMed] [Google Scholar]
  20. Herron LR, Miles GB. Gender-specific perturbations in modulatory inputs to motoneurons in a mouse model of amyotrophic lateral sclerosis. Neuroscience 226: 313–323, 2012 [DOI] [PubMed] [Google Scholar]
  21. Hoffer JA, Sugano N, Loeb GE, Marks WB, O'Donovan MJ, Pratt CA. Cat hindlimb motoneurons during locomotion. II. Normal activity patterns. J Neurophysiol 57: 530–553, 1987 [DOI] [PubMed] [Google Scholar]
  22. Iglesias C, Meunier C, Manuel M, Timofeeva Y, Delestree N, Zytnicki D. Mixed mode oscillations in mouse spinal motoneurons arise from a low excitability state. J Neurosci 31: 5829–5840, 2011 [DOI] [PMC free article] [PubMed] [Google Scholar]
  23. Kuo JJ, Lee RH, Zhang L, Heckman CJ. Essential role of the persistent sodium current in spike initiation during slowly rising inputs in mouse spinal neurones. J Physiol 574: 819–834, 2006 [DOI] [PMC free article] [PubMed] [Google Scholar]
  24. Lee RH, Heckman CJ. Paradoxical effect of QX-314 on persistent inward currents and bistable behavior in spinal motoneurons in vivo. J Neurophysiol 82: 2518–2527, 1999 [DOI] [PubMed] [Google Scholar]
  25. Li Y, Bennett DJ. Persistent sodium and calcium currents cause plateau potentials in motoneurons of chronic spinal rats. J Neurophysiol 90: 857–869, 2003 [DOI] [PubMed] [Google Scholar]
  26. Manuel M, Heckman CJ. Adult mouse motor units develop almost all of their force in the subprimary range: a new all-or-none strategy for force recruitment? J Neurosci 31: 15188–15194, 2011 [DOI] [PMC free article] [PubMed] [Google Scholar]
  27. Manuel M, Heckman CJ. Simultaneous intracellular recording of a lumbar motoneuron and the force produced by its motor unit in the adult mouse in vivo. J Vis Exp 2012: e4312, 2012 [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. Manuel M, Li Y, Elbasiouny SM, Murray K, Griener A, Heckman CJ, Bennett DJ. NMDA induces persistent inward and outward currents that cause rhythmic bursting in adult rodent motoneurons. J Neurophysiol 108: 2991–2998, 2012 [DOI] [PMC free article] [PubMed] [Google Scholar]
  29. Meehan CF, Moldovan M, Marklund SL, Graffmo KS, Nielsen JB, Hultborn H. Intrinsic properties of lumbar motor neurones in the adult G127insTGGG superoxide dismutase-1 mutant mouse in vivo: evidence for increased persistent inward currents. Acta Physiol (Oxf) 200: 361–376, 2010a [DOI] [PubMed] [Google Scholar]
  30. Meehan CF, Sukiasyan N, Zhang M, Nielsen JB, Hultborn H. Intrinsic properties of mouse lumbar motoneurons revealed by intracellular recording in vivo. J Neurophysiol 103: 2599–2610, 2010b [DOI] [PubMed] [Google Scholar]
  31. Moritz CT, Barry BK, Pascoe MA, Enoka RM. Discharge rate variability influences the variation in force fluctuations across the working range of a hand muscle. J Neurophysiol 93: 2449–2459, 2005 [DOI] [PubMed] [Google Scholar]
  32. Mottram CJ, Christou EA, Meyer FG, Enoka RM. Frequency modulation of motor unit discharge has task-dependent effects on fluctuations in motor output. J Neurophysiol 94: 2878–2887, 2005 [DOI] [PubMed] [Google Scholar]
  33. Nakanishi ST, Whelan PJ. A decerebrate adult mouse model for examining the sensorimotor control of locomotion. J Neurophysiol 107: 500–515, 2012 [DOI] [PubMed] [Google Scholar]
  34. O'Donovan MJ, Hoffer JA, Loeb GE. Physiological characterization of motor unit properties in intact cats. J Neurosci Methods 7: 137–149, 1983 [DOI] [PubMed] [Google Scholar]
  35. Oya T, Riek S, Cresswell AG. Recruitment and rate coding organisation for soleus motor units across entire range of voluntary isometric plantar flexions. J Physiol 587: 4737–4748, 2009 [DOI] [PMC free article] [PubMed] [Google Scholar]
  36. Schmitzer-Torbert N, Jackson J, Henze D, Harris K, Redish AD. Quantitative measures of cluster quality for use in extracellular recordings. Neuroscience 131: 1–11, 2005 [DOI] [PubMed] [Google Scholar]
  37. Schmitzer-Torbert N, Redish AD. Neuronal activity in the rodent dorsal striatum in sequential navigation: separation of spatial and reward responses on the multiple T task. J Neurophysiol 91: 2259–2272, 2004 [DOI] [PubMed] [Google Scholar]
  38. Stephenson JL, Maluf KS. Discharge behaviors of trapezius motor units during exposure to low and high levels of acute psychosocial stress. J Clin Neurophysiol 27: 52–61, 2010 [DOI] [PMC free article] [PubMed] [Google Scholar]
  39. Tysseling VM, Ritter L, Heckman CJ, Tresch MC. Motor unit activity patterns in awake mice (Abstract). 2012 Neuroscience Meeting Planner New Orleans, LA: Society for Neuroscience; Program No. 887.05, 2012. [Online] [Google Scholar]

Articles from Journal of Neurophysiology are provided here courtesy of American Physiological Society

RESOURCES