Abstract
Composite resin and metallic posts are the materials most employed for reconstruction of teeth presenting partial or total destruction of crowns. Resin-based cements have been widely used for cementation of ceramic crowns. The success of cementation depends on the achievement of adequate cement curing.
Objectives
To evaluate the microhardness of Variolink® II (Ivoclar Vivadent, Schaan, Liechtenstein), used for cementing ceramic crowns onto three different coronal substrate preparations (dentin, metal, and composite resin), after 7 days and 3 months of water storage. The evaluation was performed along the cement line in the cervical, medium and occlusal thirds on the buccal and lingual aspects, and on the occlusal surface.
Material and Methods
Thirty molars were distributed in three groups (N=10) according to the type of coronal substrate: Group D- the prepared surfaces were kept in dentin; Groups M (metal) and R (resin)- the crowns were sectioned at the level of the cementoenamel junction and restored with metallic cast posts or resin build-up cores, respectively. The crowns were fabricated in ceramic IPS e.max® Press (Ivoclar Vivadent, Schaan, Liechtenstein) and luted with Variolink II. After 7 days of water storage, 5 specimens of each group were sectioned in buccolingual direction for microhardness measurements. The other specimens (N=5) were kept stored in deionized water at 37ºC for three months, followed by sectioning and microhardness measurements.
Results
Data were first analyzed by three-way ANOVA that did not reveal significant differences between thirds and occlusal surface (p=0.231). Two-way ANOVA showed significant effect of substrates (p<0.001) and the Tukey test revealed that microhardness was significantly lower when crowns were cemented on resin cores and tested after 7 days of water storage (p=0.007).
Conclusion
The type of material employed for coronal reconstruction of preparations for prosthetic purposes may influence the cement properties.
Keywords: Resin cements, Hardness tests, Ceramics
INTRODUCTION
Endodontically treated teeth presenting partial or total destruction of crowns require reconstruction to create a core to provide mechanical conditions for the indirect restoration to be fixed and remain in function for a long period. The materials most employed for that purpose are composite resins and cast metallic posts.
Resin-based cements have been widely employed for cementation of metaloceramic or ceramic crowns due to their adhesive capacity to both tooth structure and restoration, combined with esthetic and mechanical properties15,22,25. Since the success of cementation depends on the achievement of a strong and long-lasting bond among cement, restoration and tooth structure30, the strength of such adhesion procedure is directly proportional to the adequate curing of the cement and is crucial to achieve optimal physical and mechanical properties and satisfactory clinical performance7.
Several factors may influence the curing of the cement used for luting ceramic crowns. These include: the composition, thickness, opacity and shade of the ceramic, which may reduce the light transmission and consequently affect the light-curing of the cement1,2,6,9,11,16,17,21,24,31,34; characteristics of substrates and luting agent5,15; incompatibility of simplified adhesive systems with self- or dual-cured resin cements23,28,29; and permeability of simplified adhesives, which ultimately compromises the bonding between the cement and the adhesive26,27.
Considering the lack of information in the literature on the possible influence of the type of material used as coronal reconstruction on the physical properties of the cement used for luting ceramic crowns, this study evaluated the microhardness of the resin cement Variolink® II along the cement line in the cervical, medium and occlusal thirds on the buccal and lingual aspects, and on the occlusal surface, when used for luting ceramic crowns on different substrates (dentin, metal, and composite resin), after 7 days and 3 months of water storage. The null hypotheses tested were that microhardness would not be influenced by the region of prepared surfaces, coronal substrate, and water storage.
MATERIAL AND METHODS
Thirty human third molars were embedded with plaster in plastic cylinders with the cementoenamel junction approximately 3 mm above the top of the cylinder. The teeth were prepared with diamond burs for full-ceramic crowns with a shoulder of 1.2 mm with internal rounded angles, and axial reduction of 1.5 mm with 6 to 10º convergence angle was performed. Occlusal reduction was performed resulting in an axial height of 4.0 mm (Figure 1a). They were randomly divided into 3 groups (N=10) as follows: Group D- the prepared crown surface was kept in dentin; Group M- the crowns were sectioned at the level of the cementoenamel junction and the core was modeled in acrylic resin DuraLay (Reliance Dental Mfg. Co. Worth, Illinois, USA), cast in aluminum-copper alloy, and luted with zinc phosphate (S. S. White Artigos Dentários Ltda., Rio de Janeiro, RJ, Brasil); Group R- the crowns were sectioned as in group M, and filling of the cores was performed with composite resin Filtek® Z250 (3M ESPE, St Paul, MN, USA) by the incremental technique. Light irradiation was obtained from a Quartz Tungsten Halogen (QTH) device V.I.P. Junior (Bisco, Schaumburg, IL, USA, 500 mW/cm2 ) for 20 s for each increment, and 40 s for the last one. The pulp chambers were cleaned and filled with the same composite resin. The reduction, convergence and height of axial walls followed the same principles described above for Group D.
Figure 1.

Scheme of experimental stages: a) prepared tooth; b) wax relief; c) cemented crown; d) sectioned crown exhibiting microhardness measurements along the cement line and ceramic thicknesses
Silicon molds were made of all sound tooth crowns before preparation. These were then used to guide the construction of the ceramic crowns to a thickness of 1.5 mm on the axial walls and 2.0 mm on the occlusal surfaces.
On the center of buccal, occlusal and lingual aspects of the prepared surfaces, a relief was made in wax with approximate thickness of 0.25 mm and width of 2.0 mm to purposely allow for a thicker cement line and permit the microhardness tests (Figure 1b). Impressions of the preparations were taken with polyvinyl siloxane Express® (3M ESPE, St Paul, MN, USA) and cast with type IV plaster.
The crowns were fabricated from the type IV models with monolithic ceramic IPS e.max® Press LT (Ivoclar Vivadent, Schaan, Liechtenstein), shade A2, following the manufacturer's instructions.
After fitting adjustments, all crowns were luted with Variolink II cement (Figure 2), following the procedures described in Figure 3, and submitted to a static load of 5 kg during light-curing process. After removal of the excess of cement, light curing was performed on the buccal, lingual and occlusal surfaces, for 40 s on each surface (Figure 1c). The specimens were then stored in lightproof flasks, immersed in deionized water and kept at 37ºC. The specimens were randomly divided in subgroups of 5 for each substrate and sectioned either after 7 days or 3 months of water storage. The storage water was changed every 15 days during this period.
Figure 2.
Chemical composition of the resin cement and adhesive system
| Cement | Adhesive System | Manufacturer | Lot |
|---|---|---|---|
| VARIOLINK II: | EXCITE DSC: | Ivoclar Vivadent, Liechtenstein | N42989 |
| Monomer matrix (bis-GMA, urethane dimethacrylate and triethyleneglycol dimethacrylate) and inorganic load (barium glass, ytterbium trifluoride, barium fluorosilicate glass and mixed aluminum and oxide spheres), catalyzers, stabilizers and pigments. | HEMA, dimethacrylate, phosphoric acid acrylate, highly dispersed silicon dioxide, initiators and stabilizers in alcohol solution. Microbrush coated with initiators. |
Figure 3.
Technical procedures
| Surface | Procedures |
|---|---|
| Dentin | Etching with 37% phosphoric acid for 15 s, rinsing for 5 s, and air-drying without dehydrating the dentin surfaces. Application of DSC adhesive followed by light-curing for 20 s. |
| Metal | Etching with 37% phosphoric acid for 15 s, rinsing for 5 s, and air-drying. |
| Composite resin | Etching with 37% phosphoric acid for 15 s, rinsing for 5 s, and air-drying. Application of adhesive followed by light-curing for 20 s. |
| Ceramic crown | Etching with 5% hydrofluoric acid for 20 s, rinsing, and air-drying. Following, silane was applied for 60 s, air-dried, and the adhesive Excite DSC was applied followed by light-curing for 20 s. |
Sectioning and Knoop hardness (KHN) measurements
The teeth were removed from the embedding cups and transversely sectioned below the crown margins using a diamond disc (Buehler, Lake Bluff, IL, USA) under constant irrigation. The crowns were then sectioned in a buccolingual direction, at the center of the relief area, to expose the cement line. To facilitate positioning of the specimen in the microhardness tester, a second parallel section limited to ceramic was made to keep the surface to be analyzed perpendicular to the indenter.
The cut surface was sequentially polished with 600- and 1200-grit SiC paper, followed by 1-µm diamond paste on a cloth, under constant irrigation. Between each polishing step, the specimens were rinsed with water for 30 s and ultrasonicated in deionized water for 2 min. The polished crown sections were kept in moist gauze in lightproof flasks until tested.
Measurements were performed on a Shimadzu Microhardness Tester Hmv-2,000 (Shimadzu Corporation - Kyoto, Japan) with Knoop indenter under a static load of 50 g for 10 s. Indentations were made from cervical to occlusal surface in 0.5 mm intervals along the cement line (Figure 1d). The hardness was expressed as a Knoop hardness number (KHN), and at the end of measurements the average microhardness values were obtained for the cervical, medium and occlusal thirds and occlusal surface.
Data treatment
Data were analyzed by three-way ANOVA (substrates, thirds/occlusal surface, and storage), and two-way ANOVA was applied (substrate/storage). Group differences were investigated by Tukey test (α=5%).
RESULTS
Data were analyzed by three-way ANOVA (substrates, thirds, and storage). Considering each factor independently, the substrates showed significant differences (p=0.000), without differences for factors storage (p=0.573) or thirds (p=0.231) (Table 1). There were interactions between substrates and storage time factors (p=0.011). Since the analysis did not reveal significant differences between thirds, the values of substrate and storage were submitted to two-way ANOVA, which showed significant effects of core materials (p<0.001). Hardness values were significantly lower when crowns were cemented on resin cores and measured after 7 days of storage (p=0.007) (Table 2, Figure 4).
Table 1.
Knoop hardness number (Standard Deviation) at cervical, middle, occlusal thirds and occlusal surface according to the conditions substrate/time storage
| Group | DENTIN | METAL | RESIN | |||
|---|---|---|---|---|---|---|
| 7 days | 3 months | 7 days | 3 months | 7 days | 3 months | |
| Cervical | 51.0 (0.8)Aa+ | 48.7 (1.1)Aa+ | 49.1 (3.1)Aa+ | 48.9 (0.3)Aa+ | 48.0 (4.6)Ab+ | 46.4 (3.8)Ab+ |
| Medium | 51.5 (1.5)Aa+ | 49.1 (1.3)Aa+ | 49.1 (2.1)Aa+ | 49.8 (0.5)Aa+ | 45.8 (4.2)Ab+ | 48.6 (3.1)Ab+ |
| Occlusal | 51.6 (1.8)Aa+ | 50.3 (0.9)Aa+ | 50.5 (2.6)Aa+ | 49.6 (1.5)Aa+ | 45.0 (4.7)Ab+ | 48.6 (2.6)Ab+ |
| Occlusal surface | 48.6 (1.3)Aa+ | 48.9 (0.8)Aa+ | 48.5 (3.6)Aa+ | 47.9 (1.2)Aa+ | 43.5 (4.9)Ab+ | 49.1 (3.4)Ab+ |
| Mean | 50.7 | 49.3 | 49.3 | 49.1 | 45.6 | 48.2 |
N=5 specimens in each group. Equal capital letters indicate lack of statistically significant difference (analysis of storage); equal lowercase letters indicate lack of statistically significant difference (analysis of substrate); equal symbols indicate lack of statistically significant difference (analysis of thirds). p<0.05
Table 2.
Knoop hardness number (Standard Deviation) of samples according to the conditions substrate/time storage
| DENTIN | METAL | RESIN | Mean | |
|---|---|---|---|---|
| 7 days | 50.7 (1.9)Aa | 49.3 (3.0)Aa | 45.6 (4.9)Bb | 48.5 |
| 3 months | 49.3 (1.2)Aa | 49.1 (1.3)Aa | 48.2 (3.4)Aa | 48.8 |
| Mean | 50 | 49.2 | 46.9 | - |
N=5 specimens in each group. Equal capital letters indicate lack of statistically significant difference (analysis by row); equal lowercase letters indicate lack of statistically significant difference (analysis by column). p<0.05
Figure 4.
Box plots: a) results after 7 days in water storage; b) results after 3 months in water storage
DISCUSSION
The fact that there were no differences among thirds and faces is probably due to the ceramic thickness employed (1.5 mm on axial walls and 2.0 mm on the occlusal aspect) and the composition of ceramic IPS e.max® Press, a vitreous ceramic composed of lithium disilicate12, which may have allowed sufficient light transmission throughout the crown extent. Pazin, et al.21 (2008) also found uniform microhardness values along the cement layer for the cement Variolink II used to cement leucite-based ceramic crowns with 1.4 mm and 2.0 mm of thickness.
Concerning the type of substrate, only the composite resin core, after storage in water for 7 days, resulted in significantly lower hardness values when compared with the other groups and storage conditions. Therefore, the anticipated hypothesis must be partially rejected.
When full crowns are cemented on metal or fiber-reinforced resin posts or cores, the permeability of the simplified adhesive will not be in effect. But when the substrate is hydrated dentin, the permeability might be more relevant and harmful than the chemical incompatibility in relation to metal and composite resin substrates22. This occurs because the fluid transudation through the adhesive may result in water accumulation at the interface between adhesive and cement, causing significant reductions in bond strength. This water accumulation is originated from the hydrated dentin, and the negative effect of this permeability on the adhesive resistance of resin cements was confirmed by in vitro studies27. When crowns are cemented on core substrates other than dentin, the permeability is absent or reduced, but the chemical incompatibility persists between the acidity of simplified adhesives and the components of the chemical curing route of resins27. The reduction of mechanical properties of composites stored in water is predominantly related to water absorption by the polymer, which is softened by the tumescence of polymeric chains and reduction of frictional strength of these chains8,33. Once saturated in water, the polymeric chains are stabilized and there is no further reduction of material properties8,20,33. The effects of humidity on the mechanical properties of resin cements have been extensively investigated, and there is consensus that the action of solvents on the polymeric chain is deleterious to the mechanical properties of the cement3,8,18,19,32,33.
As previously mentioned, it has been reported that resin monomers originated from two-step conventional and one-step self-etching adhesives may impair the co-curing and consequent bond between these types of adhesives and composites, whose curing reaction is initiated by a redox reaction between the tertiary amine and benzoyl peroxide. As a consequence, low adhesive strength values are reported when these materials are combined4,23. In an attempt to avoid this chemical incompatibility and enhance the adhesive strength, manufacturers have been adding co-initiators in adhesive systems that react with acidic resin monomers and produce phenyl or benzenesulphonic radicals that initiate the curing reaction in dual resin cements or when there is no adequate light exposure10.
The microbrush of the adhesive system used in this study contains initiators that are fundamental for the self-cure mechanism. Additionally, this mechanism requires other initiators that are originated from a composite that also presents a self-cure mechanism13,14 and may come from a dual or chemically cured reconstruction composite (when the adhesive is used for reconstruction) or dual or chemically cured cement (in cases of luting). That is to say, the self-cure mechanism of DSC® adhesive may not occur if it does not get in contact with dual or self-cured resin13,14. For this reason, if the DSC adhesive is exclusively used with a light-cured resin, it should necessarily be light-cured before placement of composite resin13,14.
Based on this assumption, it is understood that there clearly is a chemical reaction between the DSC adhesive and self-cured or dual-cured resins. This reaction should favor both the adhesive and cement curing. In this context, the DSC adhesive layer applied on the substrates, though light-cured, contained initiators of chemical reaction ready to react with initiators present in the cement Variolink® II and provide fast consolidation of curing of the DSC adhesive, also favoring the cement curing, especially in areas less accessible to light, thus characterizing a "collaboration" reaction of initiators of the adhesive and cement to enhance the curing of both. Considering that the quantity of such initiators in the adhesive is limited to the applied layer, when the adhesive was applied on dentin, all radicals were free to react with the cement. However, when the adhesive was applied on the core resin, it is speculated that some initiators of the adhesive reacted with uncured free radicals of the core resin and consequently reduced the availability of initiators to react with the cement. The consequence was that the cement cure and certainly also the adhesive cure were delayed, resulting in lower microhardness values in the initial storage period (7 days). Analysis of Table 1 reveals that, although not statistically significant, the microhardness of group R after 7 days of storage decreased from the cervical margin to the occlusal aspect, suggesting that in areas close to margins, in which the light acts on the cement curing with greater intensity, the conflict of utilization of initiators between core resin and cement is surpassed by the curing achieved by light-curing. Since the effects of this conflict are temporary, causing only a delay in the curing process, the same phenomenon is not observed after 3 months of storage.
The composite resin, when used as filling material for cores, provides advantages as easy handling, fast curing, good translucency shade, which does not interfere with the ceramic shade. However, in the routine clinical practice, the resin is often in contact with saliva for a considerable time. It is not known to which extent the lower hardness outcomes observed when cementing over the composite resin core may cause any relevant clinical problem. Further studies should be conducted to enhance the understanding on the reactions occurring between this substrate and the resin cement.
CONCLUSIONS
Based on the results, the following could be concluded:
There was no significant difference in the microhardness results between the cervical, medium, and occlusal thirds and occlusal surface;
There was significant difference in the microhardness results between substrates. For the 7-day storage period, the results of the composite resin substrate were lower than dentin and metal. After 3 months of storage, the results were similar for the 3 substrates;
The type of material employed for coronal reconstruction of preparations for prosthetic purposes may influence the cement properties.
ACKNOWLEDGMENTS
This study was financially supported by FAPESP - São Paulo Research Foundation (2010/06092-6) and was approved by the Institutional Review Board of Bauru School of Dentistry-USP (process no. 165/2009).
Funding Statement
This study was financially supported by FAPESP - São Paulo Research Foundation (2010/06092-6) and was approved by the Institutional Review Board of Bauru School of Dentistry-USP (process no. 165/2009).
REFERENCES
- 1.Blackman R, Barghi N, Duke E. Influence of ceramic thickness on the polymerization of light-cured resin cement. J Prosthet Dent. 1990;63(3):295–300. doi: 10.1016/0022-3913(90)90199-m. [DOI] [PubMed] [Google Scholar]
- 2.Borges GA, Agarwal P, Miranzi BA, Platt JA, Valentino TA, Santos PH. Influence of different ceramics on resin cement Knoop hardness number. Oper Dent. 2008;33(6):622–628. doi: 10.2341/07-155. [DOI] [PubMed] [Google Scholar]
- 3.Bortolotto T, Guillarme D, Gutemberg D, Veuthey JL, Krejci I. Composite resin vs resin cement for luting of indirect restorations: comparison of solubility and shrinkage behavior. Dent Mater J. 2013;32(5):834–838. doi: 10.4012/dmj.2013-153. [DOI] [PubMed] [Google Scholar]
- 4.Cavalcanti SC, Oliveira MT, Arais CA, Giannini M. The effect of the presence and presentation mode of co-initiators on the microtensile bond strength of dual-cured adhesive systems used in indirect restorations. Oper Dent. 2008;33(6):682–689. doi: 10.2341/08-18. [DOI] [PubMed] [Google Scholar]
- 5.Ceballos L, Garrido MA, Fuentes V, Rodríguez J. Mechanical characterization of resin cements used for luting fiber posts by nanoindentation. Dent Mater. 2007;23(1):100–105. doi: 10.1016/j.dental.2005.12.007. [DOI] [PubMed] [Google Scholar]
- 6.El-Mowafy OM, Rubo MH. Influence of composite inlay/onlay thickness on hardening of dual-cured resin cements. J Can Dent Assoc. 2000;66(3):147–147. [PubMed] [Google Scholar]
- 7.El-Mowafy OM, Rubo MH, el-Badrawy WA. Hardening of new resin cements cured through a ceramic inlay. Oper Dent. 1999;24(1):38–44. [PubMed] [Google Scholar]
- 8.Ferracane JL, Berge HX, Condon JR. In vitro aging of dental composites in water-effect of degree of conversion, filler volume, and filler/matrix coupling. J Biomed Mater Res. 1998;42(3):465–472. doi: 10.1002/(sici)1097-4636(19981205)42:3<465::aid-jbm17>3.0.co;2-f. [DOI] [PubMed] [Google Scholar]
- 9.Hooshmand T, Mahmoodi N, Keshvad A. Microhardness of a resin cement polymerized by light-emitting diode and halogen lights through ceramic. J Prosthodont. 2009;18(5):411–416. doi: 10.1111/j.1532-849X.2009.00449.x. [DOI] [PubMed] [Google Scholar]
- 10.Ikemura K, Endo T. Effect on adhesion of new polymerization initiator systems comprising 5-monosubstituted barbituric acids, aromatic sulfinate amides, and tert-butyl peroxymaleic acid in dental adhesive resin. J Appl Polym Sci. 1999;72(13):1655–1668. [Google Scholar]
- 11.Ilie N, Hickel R. Correlation between ceramics translucency and polymerization efficiency through ceramics. Dent Mater. 2008;24(7):908–914. doi: 10.1016/j.dental.2007.11.006. [DOI] [PubMed] [Google Scholar]
- 12.Ivoclar Vivadent AG. Scientific documentation IPS e.max® Press. Liechtenstein: Ivoclar Vivadent; 2005. [Google Scholar]
- 13.Ivoclar Vivadent AG. Scientific documentation Excite® DSC. Liechtenstein: Ivoclar Vivadent; 2008. [Google Scholar]
- 14.Ivoclar Vivadent AG. Scientific documentation Excite® F DSC. Liechtenstein: Ivoclar Vivadent; 2010. [Google Scholar]
- 15.Manso AP, Silva NR, Bonfante EA, Pegoraro TA, Dias RA, Carvalho RM. Cements and adhesives for all-ceramic restorations. Dent Clin North Am. 2011;55(2):311–332. doi: 10.1016/j.cden.2011.01.011. [DOI] [PubMed] [Google Scholar]
- 16.Meng X, Yoshida K, Atsuta M. Influence of ceramic thickness on mechanical properties and polymer structure of dual-cured resin luting agents. Dent Mater. 2008;24(5):594–599. doi: 10.1016/j.dental.2007.06.014. [DOI] [PubMed] [Google Scholar]
- 17.Noronha JD, Filho, Brandão NL, Poskus LT, Guimarães JGA, Silva EM. A critical analysis of the degree of conversion of resin-based luting cements. J Appl Oral Sci. 2010;18(5):442–446. doi: 10.1590/S1678-77572010000500003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Ortengren U, Elgh U, Spasenoska V, Milleding P, Haasim J, Karlsson S. Water sorption and flexural properties of a composite resin cement. Int J Prosthodont. 2000;13(2):141–147. [PubMed] [Google Scholar]
- 19.Oysaed H, Ruyter IE. Composites for use in posterior teeth: mechanical properties tested under dry and wet conditions. J Biomed Mater Res. 1986;20(2):261–271. doi: 10.1002/jbm.820200214. [DOI] [PubMed] [Google Scholar]
- 20.Park JW, Ferracane JL. Water aging reverses residual stresses in hydrophilic dental composites. J Dent Res. 2014;93(2):195–200. doi: 10.1177/0022034513513905. [DOI] [PubMed] [Google Scholar]
- 21.Pazin MC, Moraes RR, Gonçalves LS, Borges GA, Sinhoreti MA, Correr-Sobrinho L. Effects of ceramic thickness and curing unit on light transmission through leucite-reinforced material and polymerization of dual-cure luting agent. J Oral Sci. 2008;50(2):131–136. doi: 10.2334/josnusd.50.131. [DOI] [PubMed] [Google Scholar]
- 22.Pegoraro TA, Silva NR, Carvalho RM. Cements for use in Esthetic Dentistry. Dent Clin North Am. 2007;51(2):453–471. doi: 10.1016/j.cden.2007.02.003. [DOI] [PubMed] [Google Scholar]
- 23.Sanares AM, Itthagarun A, King NM, Tay FR, Pashley DH. Adverse surface interactions between one-bottle lightcured adhesives and chemical-cured composites. Dent Mater. 2001;17(6):542–556. doi: 10.1016/s0109-5641(01)00016-1. [DOI] [PubMed] [Google Scholar]
- 24.Soares CJ, Silva NR, Fonseca RB. Influence of the feldspatic ceramic thickness and shade on the microhardness of dual resin cement. Oper Dent. 2006;31(3):384–389. doi: 10.2341/05-51. [DOI] [PubMed] [Google Scholar]
- 25.Stamatacos C, Simon JF. Cementation of indirect restorations: an overview of resin cements. Compend Contin Educ Dent. 2013;34(1):42-4, 46. [PubMed] [Google Scholar]
- 26.Tay FR, Frankeberg R, Krejci I, Bouillaguet S, Pashley DH, Carvalho RM. Single-bottle adhesives behave as permeable membranes after polymerization. I. In vivo evidence. J Dent. 2004;32(8):611–621. doi: 10.1016/j.jdent.2004.04.006. [DOI] [PubMed] [Google Scholar]
- 27.Tay FR, Pashley DH, Suh BI, Carvalho RM, Itthagarun A. Single-step adhesives are permeable membranes. J Dent. 2002;30(7-8):371–382. doi: 10.1016/s0300-5712(02)00064-7. [DOI] [PubMed] [Google Scholar]
- 28.Tay FR, Pashley DH, Yiu CK, Sanares AM, Wei SH. Factors contributing to the incompatibility between simplified-step adhesives and chemically-cured or dual-cured composites. Part I. Single-step self-etching adhesive. J Adhes Dent. 2003;5(1):27–40. [PubMed] [Google Scholar]
- 29.Tay FR, Suh BI, Pashley DH, Prati C, Chuang SF, Li F. Factors contributing to the incompatibility between simplified-step adhesives and self-cured or dual-cured composites.Part II. Singlebottle total-etch adhesive. J Adhes Dent. 2003;5(2):91–105. [PubMed] [Google Scholar]
- 30.Uctasli S, Hasanreisoglu U, Wilson HJ. The attenuation of radiation by porcelain and its effect on polymerization of resin cements. J Oral Rehabil. 1994;21(5):565–575. doi: 10.1111/j.1365-2842.1994.tb01171.x. [DOI] [PubMed] [Google Scholar]
- 31.Valentino TA, Borges GA, Borges LH, Vishal J, Martins LR, Correr-Sobrinho L. Dual resin cement Knoop hardness after different activation modes through dental ceramics. Braz Dent. 2010;21(2):104–110. doi: 10.1590/s0103-64402010000200003. [DOI] [PubMed] [Google Scholar]
- 32.Vrochari AD, Eliades G, Hellwig E, et al. Water sorption and solubility of four self-etching, self-adhesive resin luting agents. J Adhes Dent. 2010;12(1):39–43. doi: 10.3290/j.jad.a17539. [DOI] [PubMed] [Google Scholar]
- 33.Walker MP, Spencer P, David Eick J. Mechanical property characterization of resin cement after aqueous aging with and without cyclic loading. Dent Mater. 2003;19(7):645–652. doi: 10.1016/s0109-5641(03)00008-3. [DOI] [PubMed] [Google Scholar]
- 34.Zhang X, Wang F. Hardness of resin cement cured under different thickness of lithium disilicate-based ceramic. Chin Med J. 2011;124(22):3762–3767. [PubMed] [Google Scholar]