Skip to main content
PLOS One logoLink to PLOS One
. 2014 Sep 8;9(9):e105803. doi: 10.1371/journal.pone.0105803

Development of New Multilocus Variable Number of Tandem Repeat Analysis (MLVA) for Listeria innocua and Its Application in a Food Processing Plant

Hajime Takahashi 1,*, Chihiro Ohshima 1, Miku Nakagawa 1, Krittaporn Thanatsang 2, Chirapiphat Phraephaisarn 3, Yuphakhun Chaturongkasumrit 1, Suwimon Keeratipibul 2, Takashi Kuda 1, Bon Kimura 1
Editor: Yung-Fu Chang4
PMCID: PMC4157758  PMID: 25198191

Abstract

Listeria innocua is an important hygiene indicator bacterium in food industries because it behaves similar to Listeria monocytogenes, which is pathogenic to humans. PFGE is often used to characterize bacterial strains and to track contamination source. However, because PFGE is an expensive, complicated, time-consuming protocol, and poses difficulty in data sharing, development of a new typing method is necessary. MLVA is a technique that identifies bacterial strains on the basis of the number of tandem repeats present in the genome varies depending on the strains. MLVA has gained attention due to its high reproducibility and ease of data sharing. In this study, we developed a MLVA protocol to assess L. innocua and evaluated it by tracking the contamination source of L. innocua in an actual food manufacturing factory by typing the bacterial strains isolated from the factory. Three VNTR regions of the L. innocua genome were chosen for use in the MLVA. The number of repeat units in each VNTR region was calculated based on the results of PCR product analysis using capillary electrophoresis (CE). The calculated number of repetitions was compared with the results of the gene sequence analysis to demonstrate the accuracy of the CE repeat number analysis. The developed technique was evaluated using 60 L. innocua strains isolated from a food factory. These 60 strains were classified into 11 patterns using MLVA. Many of the strains were classified into ST-6, revealing that this MLVA strain type can contaminate each manufacturing process in the factory. The MLVA protocol developed in this study for L. innocua allowed rapid and easy analysis through the use of CE. This technique was found to be very useful in hygiene control in factories because it allowed us to track contamination sources and provided information regarding whether the bacteria were present in the factories.

Introduction

Listeria is a genus of gram-positive, facultatively anaerobic, non-spore forming bacteria [1]. Listeria spp. have been isolated from a variety of environmental sources, such as soil [2], river water [3], farm environments [4], and animal feed [5]. Additionally, Listeria spp. have been isolated from some foods [6], [7], [8] and food processing environments [9]. Because Listeria monocytogenes, a member of Listeria spp., can cause serious listeriosis infections in humans and ruminants, this pathogen is of significant health concern. L. ivanovii can also cause listeriosis infections in ruminants but rarely in humans [10].

Human listeriosis results from ingestion of L. monocytogenes via contaminated foods. Therefore, the United States has a zero-tolerance policy for contamination in processed foods, with certain exceptions, and the contamination level of L. monocytogenes in processed foods is strictly regulated at <100 cfu/g in the EU [1], [11].

Although Listeria spp. other than L. monocytogenes and L. ivanovii are not pathogenic for humans and animals, their presence in food products is still unacceptable to both the food exporters and importers. Therefore, in food industry, other Listeria spp. remain a major concern [12].

L. innocua in particular is considered to be similarly distributed and behave similarly to L. monocytogenes [12], [13] and is the most frequently isolated species [12], according to a report, among Listeria spp. in food manufacturing sites. For this reason, establishment of a monitoring method and clarification of contamination sources and routes are required.

Pulsed-field gel electrophoresis (PFGE) is widely used to assess the distribution of bacteria in foods and food manufacturing sites. PFGE, considered the gold standard technique due to its high resolution, has obvious disadvantages, including a complicated protocol, skill requirement, and time-consuming analysis [14]. In addition, multilocus sequence typing (MLST) and multilocus variable number of tandem repeat analysis (MLVA) have been developed as typing methods that use DNA sequence analysis. MLVA is a technique that types bacterial strains by utilizing the fact that the number of repeat units in the variable number tandem repeat (VNTR) region varies depending on the strain. Comparison of the numbers of repeats in multiple VNTR regions allows highly specific strain classification [15]. Analytical methods using VNTR regions have been developed for various food microorganisms, such as Listeria monocytogenes [14], [15], [16], Escherichia coli [17], Bacillus anthracis [18], Salmonella enterica [19], and Vibrio parahaemolyticus [20], showing the efficacy of MLVA as a strain identification method.

In this study, we developed an MLVA method effective for distribution assessment and tracking the contamination sources of L. innocua. Capillary electrophoresis (CE), with a simpler protocol and analysis procedure compared to sequence analysis, was used for MLVA because it is readily applied in food manufacturing sites. Moreover, we evaluated this MLVA protocol by using L. innocua isolated from a food factory and elucidated the contamination route of L. innocua in the factory.

Materials and Methods

MLVA primer design

Whole genome data of the Listeria innocua CLIP11262 strain was obtained from GenBank. Targeted VNTR regions of the Listeria innocua CLIP11262 strain were listed by using the Tandem Repeat Finder program (http://tandem.bu.edu/trf/trf.html) (Benson, 1999). Primer sets for amplification of each VNTR region were determined with the Primer Express Software (Life Technologies, Foster City, CA). The primer sets were designed within 300 bp from the end of VNTR regions to minimize the length of flanking regions.

DNA extraction

Eighteen strains of L. innocua stored in our laboratory were used to evaluate of the developed MLVA method (Table 1). Of these strains, 8 strains were isolated from swab samples of food processing plants, and 10 strains were isolated from the environment in Japan (GPS 41.820; 140.653, 41.883; 140.638, 41.882; 140.639, 41.984; 140.681, 41.954; 140.709, 41.826; 140.735, 41.806; 140.715, 41.809; 140.708, 42.126; 140.735, 42.257; 140.254). The sampling site is located in open access area and no specific permissions are required to collect samples.

Table 1. Characteristics of L. innocua isolates used for development of the MLVA method.

Strains Sampling Site
1-2-1 Food processing plant
1-8-1 Food processing plant
1-25-1 Food processing plant
1-28-1 Food processing plant
1-29-1 Food processing plant
2-28-1 Food processing plant
2-29-1 Food processing plant
2-35-1 Food processing plant
6-5-3 Environment
7-4-1 Environment
6-9-2 Environment
7-10-3 Environment
11-10-1 Environment
6-12-1 Environment
6-16 Environment
7-15-2 Environment
26-1-1 Environment
57-2 Environment

Strains were grown in trypticase soy broth (TSB; Becton Dickinson and Company) overnight at 37°C. Bacterial cells were harvested from 1 mL TSB by centrifugation at 8,000×g for 3 min, and the supernatant was removed. DNA extraction was conducted using the NucleoSpin Tissue Kit (Macherey-Nagel GmbH & Co. KG, Düren, Germany), according to the manufacturer's protocol.

Amplification of VNTRs

PCR was performed in a final volume of 50 µL. The PCR reaction mix contained 10 mM Tris-HCl (pH 8.3), 50 mM KCl, 1.5 mM MgCl2, 0.2 mM each of dNTPs, 1 mM forward primer, 1 mM reverse primer, 25 ng of template DNA, and 0.5 U Takara Taq DNA polymerase (Takara Bio). Amplification was performed using the GeneAmp PCR System 9700 Thermalcycler (Life Technologies). The following parameters were used for amplification: 94°C for 5 min, 30 cycles of 94°C for 30 s, 60°C for 40 s, and 72°C for 1 min, and 72°C for 1 min.

Capillary electrophoresis

The sizes of PCR products were analyzed by capillary electrophoresis (QIAexcel, Qiagen) and determined by QIAxcel ScreenGel software (Qiagen). The DNA High Resolution Kit Gel Cartridge (Qiagen) was used in this study. The number of repeat units in each VNTR region were calculated from their product size using modeling sizes, which were defined by the sequence data of Listeria innocua CLIP 11262 strain. The sizes of PCR products obtained from capillary electrophoresis were assumed to be the closest modeling size of PCR products, and the number of repeat units were determined.

Confirmation of the number of repeat units using sequencing

The PCR products obtained were purified using Agencourt AMPure (Beckman Coulter), according to the manufacturer's protocol. Following purification, the amplification products were sequenced using the BigDye Terminator v3.1 Cycle Sequencing Kit (Life Technologies), according to the manufacturer's protocol. The primer sets used for sequencing reactions were the same as those used for amplification. After completion of the sequencing reaction, the sequence was determined using an ABI 3130 Genetic Analyzer (Life Technologies). A consensus region was resolved by Genetix-ATGC using the sequences from each primer, and the numbers of repeat units were counted. The numbers of repeat units were compared with the results of capillary electrophoresis. Furthermore, the differences between sequences in repeat units were checked.

Evaluation of the developed method using food industry strains

The developed method was evaluated by typing 60 L. innocua strains isolated from a food processing plant. These strains were obtained from laboratory collection which covers a two-year period of monthly environmental monitoring isolates from various processes, including steam, chilling, cutting, freezing, and packing. These environmental swab samples were intentionally taken from the areas that are difficult to access for cleaning in order to monitoring the persistent of L. innocua. Cultivation and extraction of DNA were conducted as previously described. VNTR regions of TR-D, TR-E, and TR-J were amplified using developed methods. PCR products were analyzed by capillary electrophoresis, and the numbers of repeat units were calculated. Allele numbers were assigned based on the numbers of repeat units, which were calculated from the results of capillary electrophoresis.

Results

Determination of VNTR regions

In total, 100 candidate VNTR regions were obtained as a result of the whole genome database search of the L. innocua CLIP11262 strain using Tandem Repeat Finder. Among them, three VNTR regions, TR-D, TR-E, and TR-J, with the sequence length suitable for MLVA using CE, were chosen, and their corresponding primer sets were designed (Table 2). Table 3 shows characteristics of the VNTR regions used in the MLVA. The repeat units in the three VNTR regions had 6–9 bases each (Table 3).

Table 2. Primer sets for MLVA analysis.

TR Primer Sequence (5′-3′) Location in CLIP11262 Amplicon size
TR-D D-forward GACAAAAGTAAGTCATGCGGGTATTT 1124253–1124395 440 bp
D-reverse TAGCTACAATCGGATTAACGG
TR-E E-forward GTACCTCCATTTGCTGTTCCA 1924244–1924320 256 bp
E-reverse ATGTTATCCACCTTCAAGTAACTG
TR-J J-forward ATGTTTGTGTTCTCAGTTGCC 2741368–2741485 369 bp
J-reverse CTACCAAGGATTACTACAAGAAC

Table 3. Sequence of repeat unit and part of the flanking region of the variable number of tandem repeats (VNTR) regions.

Locus Flanking region (5′) Sequence of repeat unit Flanking region (3′) Allele number
Length(bp) partial sequence Length(bp) partial sequence
TR-D 161 agccactgttggagaagc CGGTAGACC 117 caatcactccagtagacc {X-(161+117)}/9
TR-E 58 tagtacctcctc CATCGG 90 aatcaactaatg {X-(58+90)}/6
TR-J 79 ctgctggttgaatcggat TTACTGGGT 173 ctaccggaactactggat {X-(79+173)}/9

Formula for calculating the allele number on the basis of the fragment size.

Development of the MLVA method for L. innocua

The 18 L. innocua strains stored in our laboratory derived from food factories and the environment were each subjected to MLVA. In this study, the numbers of repeat units were calculated by using the model size designed first after determining the length of the PCR product using CE. As a result, the numbers of repeats in the VNTR regions were 9–21, 13–18, and 3–14 in TR-D, TR-E, and TR-J, respectively. The numbers of alleles in the regions were 6, 5, and 7 in TR-D, TR-E, and TR-J, respectively.

Next, the numbers of repeat units obtained from the CE result were confirmed by sequencing. The following concept was applied to counting the number of repeats by sequencing. Mutation of a base per three bases in a repeat unit was allowed. For example, for the repeat unit in TR-E, CATCGG, if it was mutated to CTTCAG or CATCCG, it was also treated as a repeat unit.

Consequently, TR-D in 16 out of 18 strains was found to have different bases equivalent to the two repeats, which were 12 bases (Table 4). In addition, there were two strains in which the number of repeat in TR-J was different between the CE results and sequencing. The sequencing results confirmed a slight difference in the sequence of the repeat unit in all three regions.

Table 4. Compared MLVA profile of 18 L. innocua strains which identified by sequencing or capillary electrophoresis.

D E J
Strain no. Ampliconsize (bp) Closest amplicon size of the RU model Number of repetitions from CE Number of repetitions from sequencing Number of the difference of repetitions Number of inserted sequence (bp) Ampliconsize (bp) Closest amplicon size of the RU model Number of repetition from CE Number of repetition from sequencing Number of the difference of repetition Ampliconsize (bp) Closest amplicon size of the RU model Number of repetition from CE Number of repetition from Sequencing Number of the difference of repetition
1-2-1 479 476 22 20 2 12 243 244 16 16 0 382 378 14 14 0
1-8-1 478 476 22 20 2 12 244 244 16 16 0 373 369 13 13 0
1-25-1 479 476 22 20 2 12 244 244 16 16 0 373 369 13 13 0
1-28-1 478 476 22 20 2 12 244 244 16 16 0 374 369 13 13 0
1-29-1 480 476 22 20 2 12 246 244 16 16 0 347 351 11 10 1
2-28-1 487 485 23 21 2 12 244 244 16 16 0 346 342 10 10 0
2-29-1 478 476 22 20 2 12 245 244 16 16 0 373 369 13 13 0
2-35-1 480 476 22 20 2 12 245 244 16 16 0 346 351 11 11 0
6-5-3 397 395 13 11 2 12 226 226 13 13 0 307 306 6 6 0
7-4-1 381 381 11 9 2 12 232 232 14 14 0 301 297 5 5 0
6-9-2 369 368 10 10 0 0 257 256 18 18 0 380 378 14 14 0
7-10-3 388 386 12 10 2 12 226 226 13 13 0 310 306 6 6 0
11-10-1 374 377 11 9 2 12 234 232 14 14 0 301 297 5 5 0
6-12-1 369 368 10 10 0 0 257 256 18 18 0 380 378 14 14 0
6-16 387 386 12 10 2 12 256 256 18 18 0 338 342 10 9 1
7-15-2 454 458 20 18 2 12 243 244 16 16 0 283 279 3 3 0
26-1-1 387 386 12 10 2 12 226 226 13 13 0 308 306 6 6 0
57-2 377 377 11 9 2 12 237 238 15 15 0 301 297 5 5 0

Sequence type (ST) was determined in each strain based on the pattern of the repeat numbers in TR-D, TR-E, and TR-J. When CE was used, the 20 strains were classified into 12 types, as opposed to 11 types when using sequence analysis.

Evaluation of the established MLVA protocol using strains isolated from a food factory

Sixty L. innocua strains that were isolated from a food factory were subjected to MLVA using CE. As a result, the strains were classified into 5 patterns for TR-D and 4 patterns for TR-E and TR-J, allowing us to classify the strains into 11 patterns by combining the three regions (Table 5).

Table 5. The result of MLVA analysis for 60 L. innocua isolated from food processing plant.

Sample no. D E J MLVA-ST Source of isolate
No. of repeat unit No. of repeat unit No. of repeat unit
124 12 13 6 1 Packaging area
133 12 13 6 1 Chilling area
235 12 13 6 1 Worker's hand
276 19 16 11 2 Worker's boots
13 20 16 11 3 Chilling area
9 20 17 11 4 Freezing area
277 23 15 13 5 Freezing area
77 23 16 11 6 Cutting area
20 23 16 11 6 Cutting area
29 23 16 11 6 Cutting area
260 23 16 11 6 Heating area
262 23 16 11 6 Heating area
48 23 16 11 6 Packaging area
4 23 16 11 6 Cutting area
24 23 16 11 6 Worker's hand
25 23 16 11 6 Freezing area
26 23 16 11 6 Freezing area
33 23 16 11 6 Cutting area
43 23 16 11 6 Freezing area
54 23 16 11 6 Chilling area
75 23 16 11 6 Packaging area
84 23 16 11 6 Packaging area
87 23 16 11 6 Freezing area
98 23 16 11 6 Freezing area
107 23 16 11 6 Packaging area
108 23 16 11 6 Chilling area
121 23 16 11 6 Cutting area
143 23 16 11 6 Cutting area
148 23 16 11 6 Cutting area
175 23 16 11 6 Cutting area
185 23 16 11 6 Freezing area
211 23 16 11 6 Chilling area
252 23 16 11 6 Packaging area
290 23 16 11 6 Heating area
299 23 16 11 6 Cutting area
31 23 16 11 6 Packaging area
82 23 16 11 6 Packaging area
117 23 16 11 6 Heating area
126 23 16 11 6 Chilling area
303 23 16 11 6 Cutting area
144 23 16 11 6 Cutting area
281 23 16 11 6 Cutting area
100 23 16 12 7 Cutting area
40 23 16 13 8 Heating area
78 23 16 13 8 Worker's hand
152 23 16 13 8 Heating area
181 23 16 13 8 Cutting area
187 23 16 13 8 Freezing area
308 23 16 13 8 Heating area
30 23 16 13 8 Heating area
304 23 16 13 8 Chilling area
286 23 16 13 8 Cutting area
306 23 16 13 8 Freezing area
269 23 16 14 9 Freezing area
1 23 17 10 10 Freezing area
3 23 17 11 11 Packaging area
5 23 17 11 11 Cutting area
311 23 17 11 11 Chilling area
313 23 17 11 11 Cutting area
49 24 16 11 11 Chilling area

When focusing on the distribution of the MLVA patterns in the factory, L. innocua isolated from areas for freezing/packaging showed six MLVA patterns, the highest number of patterns when compared to other areas. The strains classified as MLVA-ST6 were isolated from heating, freezing, and packaging process areas in the factory.

Discussion

L. monocytogenes, which is pathogenic to humans, is strictly controlled for in food factories, and a number of methods for tracking contamination sources of this pathogen have been published [21], [22]. In this study, we developed an MLVA method for L. innocua, which is predicted to be an indicator bacterium of L. monocytogenes contamination due to its similar behavior [12], [13], and tracked the contamination source using strains isolated from an actual food factory.

DNA typing methods that are widely used for epidemiological surveys and tracking contamination sources include PFGE [22]. However, the disadvantages of PFGE range from a complicated protocols, time consumption, to difficulty in data comparison due the results being a band pattern [1]. One DNA typing method reported for L. innocua is random amplified polymorphic DNA (RAPD) [12]. RAPD has low reproducibility, and the analysis is cumbersome to share because the electrophoresis results have to be converted into comparable data. On the other hand, in MLVA, the protocol is easier, and the analysis is shorter than that of PFGE and RAPD. In addition, because the data obtained are not a band pattern, it is easy to share and compare the data [1]. Because of those properties, MLVA is very convenient for food companies and other industries with multiple factories.

In the MLVA protocol established in this experiment, the analytical conditions allowed for base mismatching per three bases (3/9, 2/6, and 3/9 bases in TR-D, TR-E, and TR-J regions, respectively) included in the repeat unit. The length of flanking regions outside the repeat units was fixed in the model case of each region [23]. When the typing profiles from the analysis under these conditions were compared with that from the sequence analysis, the number of the repeat unit was same between CE and sequencing in TR-E. There were two strains in which the length of the PCR product from TR-J analyzed by CE was 4 bases longer than that determined by sequencing. However, other strains had the same number of repeats between the two methods. Sixteen out of 18 strains had different numbers of repeat units in TR-D between CE and sequencing. When the sequences were compared between the CLIP11262 strain used for setting conditions and 18 strains used in the experiment, insertions of 12 bases in the flanking regions were found in strains with different numbers of repeat units. Because the repeat unit in TR-D has 6 bases, insertion of these 12 bases led to an estimated two more repeats of the unit. These results revealed that CE (QIAexcel) used in this experiment was sufficiently specific and usable in the analysis of the numbers of repeat units in MLVA.

Analysis of L. innocua isolated from food processing factory using MLVA-CE established in this study resulted in the classification of 60 strains into 11 STs and revealed the presence of L. innocua with multiple STs in this factory. Many of the 60 strains isolated from the factory were classified as ST6. The strains classified as ST6 were isolated from many areas of factory during different time period of sampling, revealing that this strain of L. innocua is widely distributed in the factory and transferred from area to area. In this factory, the area for processing chicken meat before heating and the area for handling products after steaming are connected by steaming aperture, but the workers are completely independent between the areas. During operation of steamer, there is no situation in which L. innocua attached to the raw materials constitutively enters the post-steaming area. However, when cleaning procedure is applied after the end of the operation, it is likely that the organism survived in pre-heating area could pass through post-steaming area by this channel and disperse to the areas of cooling, cutting, freezing, and packing by various routes. Due to the fact that L. innocua ST6 was isolated from the processing areas at all two-year period, it is likely that L. innocua resides and persistently contaminate in the factory.

Although this factory was routinely cleaned carefully and the air temperature was maintained at 10°C, ST6 strains were shown to reside in many areas. With this in mind, these strains are likely to be highly resistant to various environmental stresses. Other strains were likely to reside at lower frequency than that of ST6, as they were isolated from two sites at most.

In this study, we established an MLVA protocol for L. innocua by using CE that allows a simpler work process, shorter analysis duration, and cost reduction. In the evaluation of the established technique using strains isolated from a food factory, this MLVA protocol allowed us to obtain information on the actual status of contamination and bacterial is residence in the factory, demonstrating the high usefulness for hygiene control in factories. These data indicate that the MLVA-CE protocol is very effective as a highly identifiable and simple typing method.

Data Availability

The authors confirm that all data underlying the findings are fully available without restriction. All relevant data are within the paper and its Supporting Information files.

Funding Statement

This work was supported by Grant-in-Aid for Scientific Research (B 24380115) from the Ministry of Education, Science, Sports and Culture of Japan and The Towa Foundation for Food Research. One of the authors KT was supported by the Chulalongkorn University's Graduate scholarship. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

References

  • 1. Jadhav S, Bhave M, Palombo EA (2012) Methods used for the detection and subtyping of Listeria monocytogenes . J Microbiol Meth 88: 327–341. [DOI] [PubMed] [Google Scholar]
  • 2. Sauders BD, Overdevest J, Fortes E, Windham K, Schukken Y, et al. (2012) Diversity of Listeria species in urban and natural environments. Appl Environ Microbiol 78: 4420–4433. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3. Lyautey E, Lapen DR, Wilkes G, McCleary K, Pagotto F, et al. (2007) Distribution and characteristics of Listeria monocytogenes isolates from surface waters of the South Nation River watershed, Ontario, Canada. Appl Environ Microbiol 73: 5401–5410. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Fox E, O'Mahony T, Clancy M, Dempsey R, O'Brien M, et al. (2009) Listeria monocytogenes in the Irish dairy farm environment. J Food Prot 72: 1450–1456. [DOI] [PubMed] [Google Scholar]
  • 5. Vongkamjan K, Switt AM, Bakker HC, Fortes ED, Wiedmann M (2012) Silage collected from dairy farms harbors an abundance of Listeriaphages with considerable host range and genome size diversity. Appl Environ Microbiol 78: 8666–8675. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6. González D, Vitas AI, Díez-Leturia M, García-Jalón I (2013) Listeria monocytogenes and ready-to-eat seafood in Spain: study of prevalence and temperatures at retail. Food Microbiol 36: 374–378. [DOI] [PubMed] [Google Scholar]
  • 7. Miya S, Takahashi H, Ishikawa T, Fujii T, Kimura B (2010) Risk of Listeria monocytogenes contamination of raw ready-to-eat seafood products available at retail outlets in Japan. Appl Environ Microbiol 76(10): 3383–3386. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. Ochiai Y, Yamada F, Batmunkh O, Mochizuki M, Takano T, et al. (2010) Prevalence of Listeria monocytogenes in retailed meat in the Tokyo metropolitan area. J Food Prot 73: 1688–1693. [DOI] [PubMed] [Google Scholar]
  • 9.Fox E, Hunt K, O'Brien M, Jordan K (2011) Listeria monocytogenes in Irish Farmhouse cheese processing environments. Int J Food Microbiol (Suppl. 1): S39–S45. [DOI] [PubMed]
  • 10. Guillet C, Join-Lambert O, Le Monnier A, Leclercq A, Mechaï F, et al. (2010) Human listeriosis caused by Listeria ivanovii . Emerg Infect Dis 16: 136–138. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Swaminathan B (2001) Listeria monocytogenes. In: Doyle MP, Beuchat LR, Montville TJ, (Eds), Food microbiology, Fundanmentals and Frontiers ASM Press Washington DC pp: 383–409. [Google Scholar]
  • 12. Suwimon K, Punnida T (2012) Tracking sources of Listeria contamination in a cooked chicken meat factory by PCR-RAPD-based DNA fingerprinting. Food Control 27: 64–72. [Google Scholar]
  • 13. Oliveira M, Usall J, Viñas I, Solsona C, Abadias M (2011) Transfer of Listeria innocua from contaminated compost and irrigation water to lettuce leaves. Food Microbiol 28: 590–596. [DOI] [PubMed] [Google Scholar]
  • 14. Chenal-Francisque V, Diancourt L, Cantinelli T, Passet V, Tran-Hykes C, et al. (2013) Optimized Multilocus variable-number tandem-repeat analysis assay and its complementarity with pulsed-field gel electrophoresis and multilocus sequence typing for Listeria monocytogenes clone identification and surveillance. J Clin Microbiol 51: 1868–1880. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Miya S, Kimura B, Sato M, Takahashi H, Ishikawa T, et al. (2008) Development of a multilocus variable-number of tandem repeat typing method for Listeria monocytogenes serotype 4b strains. Int J Food Microbiol 124: 239–249. [DOI] [PubMed] [Google Scholar]
  • 16. Miya S, Takahashi H, Kamimura C, Nakagawa M, Kuda T, et al. (2012) Highly discriminatory typing method for Listeria monocytogenes using polymorphic tandem repeat regions. J Microbiol Methods 90: 285–291. [DOI] [PubMed] [Google Scholar]
  • 17. Keys C, Kemper S, Keim P (2005) Highly diverse variable number tandem repeat loci in the E. coli O157: H7 and O55: H7 genomes for high-resolution molecular typing. Journal of Applied Microbiology 98: 928–940. [DOI] [PubMed] [Google Scholar]
  • 18. Keim P, Price LB, Klevytska AM, Smith KL, Schupp JM, et al. (2000) Multiple-locus variable-number tandem repeat analysis reveals geneticrelationships within Bacillus anthracis . J Bacteriol 182: 2928–2936. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19. Lindstedt BA, Vardund T, Aas L, Kapperud G (2004) Multiple-locus variable-number tandem-repeats analysis of Salmonella enterica subsp. enterica serovar Typhimurium using PCR multiplexing and multicolor capillary electrophoresis. J Microbiol Methods 59: 163–172. [DOI] [PubMed] [Google Scholar]
  • 20. Kimura B, Sekine Y, Takahashi H, Tanaka Y, Obata H, et al. (2008) Multiple-locus variable-number of tandem-repeats analysis distinguishes Vibrio parahaemolyticus pandemicO3: K6 strains. J Microbiol Methods 72: 313–320. [DOI] [PubMed] [Google Scholar]
  • 21. Thimothe J, Nightingale KK, Gall K, Scott VN, Wiedmann M (2004) Tracking of Listeria monocytogenes in smoked fish processing plants. J Food Prot 67: 328–341. [DOI] [PubMed] [Google Scholar]
  • 22. Williams SK, Roof S, Boyle EA, Burson D, Thippareddi H (2011) Molecular ecology of Listeria monocytogenes and other Listeria species in small and very small ready-to-eat meat processing plants. J Food Prot 74: 63–77. [DOI] [PubMed] [Google Scholar]
  • 23.Larsson JT, Torpdahl M, Petersen RF, Sorensen G, Lindstedt BA (2009) Development of a new nomenclature for Salmonella typhimurium multilocus variable number of tandem repeats analysis (MLVA). Euro Surveill 14. [PubMed]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The authors confirm that all data underlying the findings are fully available without restriction. All relevant data are within the paper and its Supporting Information files.


Articles from PLoS ONE are provided here courtesy of PLOS

RESOURCES