Abstract
Levels of antibodies in sera from patients with diagnoses of subclinical or established psittacosis infections were determined by the serum neutralization anti-IgG test and by conventional tests. Relatively high levels of serum neutralizing anti-bodies were detected in tests in which anti-IgG was used, whereas conventional tests disclosed only marginal levels of antibody. Use of the serum neutralization anti-IgG test in conjunction with the fluorescent cell-counting technique permitted serum antibody determinations within 24 hr.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Ashe W. K., Notkins A. L. Neutralization of an infectious herpes simplex virus-antibody complex by anti-gamma-globulin. Proc Natl Acad Sci U S A. 1966 Aug;56(2):447–451. doi: 10.1073/pnas.56.2.447. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brown A., Elsner V., Zebovitz E., Allen W. P. Use of an antiglobulin plaque neutralization test among group A arboviruses. Proc Soc Exp Biol Med. 1969 Mar;130(3):718–722. doi: 10.3181/00379727-130-33641. [DOI] [PubMed] [Google Scholar]
- COONS A. H., KAPLAN M. H. Localization of antigen in tissue cells; improvements in a method for the detection of antigen by means of fluorescent antibody. J Exp Med. 1950 Jan 1;91(1):1–13. doi: 10.1084/jem.91.1.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- DULBECCO R., VOGT M., STRICKLAND A. G. A study of the basic aspects of neutralization of two animal viruses, western equine encephalitis virus and poliomyelitis virus. Virology. 1956 Apr;2(2):162–205. doi: 10.1016/0042-6822(56)90017-4. [DOI] [PubMed] [Google Scholar]
- FERNANDES M. V. Irradiation of cells in tissue culture. VII. Studies on the susceptibility to bluetongue virus on radiation induced giant cells in vitro. Z Zellforsch Mikrosk Anat. 1959;50:433–443. [PubMed] [Google Scholar]
- GRANOFF A. THE INTERACTION OF NEWCASTLE DISEASE VIRUS AND NEUTRALIZING ANTIBODY. Virology. 1965 Jan;25:38–47. doi: 10.1016/0042-6822(65)90249-7. [DOI] [PubMed] [Google Scholar]
- HAHON N., COOKE K. O. FLUORESCENT CELL-COUNTING NEUTRALIZATION TEST FOR PSITTACOSIS. J Bacteriol. 1965 Jun;89:1465–1471. doi: 10.1128/jb.89.6.1465-1471.1965. [DOI] [PMC free article] [PubMed] [Google Scholar]
- HAHON N., NAKAMURA R. M. QUANTITATIVE ASSAY OF PSITTACOSIS VIRUS BY THE FLUORESCENT CELL-COUNTING TECHNIQUE. Virology. 1964 Jun;23:203–208. doi: 10.1016/0042-6822(64)90283-1. [DOI] [PubMed] [Google Scholar]
- Hahon N. Neutralization anti-IgG test for antisera to Venezuelan equine encephalomyelitis. J Gen Virol. 1970 Feb;6(2):285–291. doi: 10.1099/0022-1317-6-2-285. [DOI] [PubMed] [Google Scholar]
- Notkins A. L., Mahar S., Scheele C., Goffman J. Infectious virus-antibody complex in the blood of chronically infected mice. J Exp Med. 1966 Jul 1;124(1):81–97. doi: 10.1084/jem.124.1.81. [DOI] [PMC free article] [PubMed] [Google Scholar]
- RODRIGUEZ J., DEINHARDT F. Preparation of a semipermanent mounting medium for fluorescent antibody studies. Virology. 1960 Oct;12:316–317. doi: 10.1016/0042-6822(60)90205-1. [DOI] [PubMed] [Google Scholar]
