Abstract
A novel open tubular nanoproteomic platform featuring accelerated on-line protein digestion and high-resolution nano liquid chromatography mass spectrometry (LC-MS) has been developed. The platform features very narrow open tubular columns, and is hence particularly suited for limited sample amounts. For enzymatic digestion of proteins, samples are passed through a 20 µm inner diameter (ID) trypsin + endoproteinase Lys-C immobilized open tubular enzyme reactor (OTER). Resulting peptides are subsequently trapped on a monolithic pre-column and transferred on-line to a 10 µm ID porous layer open tubular (PLOT) liquid chromatography LC separation column. Wnt/ß-catenein signaling pathway (Wnt-pathway) proteins of potentially diagnostic value were digested+detected in targeted-MS/MS mode in small cell samples and tumor tissues within 120 minutes. For example, a potential biomarker Axin1 was identifiable in just 10 ng of sample (protein extract of ∼1,000 HCT15 colon cancer cells). In comprehensive mode, the current OTER-PLOT set-up could be used to identify approximately 1500 proteins in HCT15 cells using a relatively short digestion+detection cycle (240 minutes), outperforming previously reported on-line digestion/separation systems. The platform is fully automated utilizing common commercial instrumentation and parts, while the reactor and columns are simple to produce and have low carry-over. These initial results point to automated solutions for fast and very sensitive MS based proteomics, especially for samples of limited size.
Introduction
As cancer medicine evolves towards personalized treatment, the need for high throughput, selective and sensitive methods for monitoring key diagnostic-value biomolecules is increasing [1]–[3]. In this regard, much diagnosis-relevant sample measurements are expected to be performed at the gene/mRNA level, and several high-throughput genetic testing methods have been developed for e.g. breast, colon, prostate and colorectal cancer [4]–[7]. Still, changes in the gene expression might not be reflected on the level of protein expression or function [8], [9]. Measuring proteins is therefore important for understanding the link between gene, gene variants and their contribution to the pathology of disease [10]. Although protein identification/measurement with e.g. Western Blotting (WB) has been predicted to have an increasingly larger role in clinics, WB has several disadvantages, e.g. limited numbers of analytes per test and selectivity issues [11].
MS based approaches can provide additional information with higher throughput, selectivity or sensitivity compared to e.g. WB, ELISA, DNA and mRNA sequencing [11]–[14]. However, standard protein MS methodologies can be very slow; cleaving proteins into MS-friendly peptides can demand overnight treatment (typically performed with the enzymes trypsin and/or Lys-C), and comprehensive LC-electrospray ionization (ESI) MS processes can take tens of hours [15]–[24]. The lengthy LC-MS processing is much related to the inability of standard LC to sufficiently separate all of the peptides in a mixture (which can be hundreds of thousands), that in turn compromises the ESI step (i.e. co-eluting peptides suppressing the signal of one another). Therefore, a goal in the LC-MS based proteomics is to develop novel LC columns/materials that provide improved separation, i.e. high peak capacity; contemporary approaches include development of monolithic materials (silica and organic [25], [26]), ultra high performance LC (UHPLC) [27] and fused core particle materials [28].
The rate-limiting step of the enzymatic cleaving of proteins is the use of relatively slow in-solution procedures. Thus, another goal is to develop procedures that accelerate the enzyme reaction step: one approach is the use of immobilized enzyme reactors (IMERs), as they have several advantages compared to standard in-solution/in-gel approaches, such as larger enzyme to substrate ratio, higher digestion efficiency, long-term stability and reusability [29], [30].
For improving both LC separation and accelerate enzymatic digestion, we have recently demonstrated the proof of principle of using a (manually operated) “lab-on-a column” system with open tubular columns (instead of particle packed/polymer-filled columns used nearly invariably in today's LC laboratories). Specifically, trypsin was immobilized on to 20 µm ID polymer-wall coated capillaries (OTERs), cleaving an isolated small cell lung cancer (SCLC) marker (ProGRP) into peptides that were subsequently separated by high peak capacity PLOT LC columns (10 µm ID [31]), with cleavage and LC-MS run time of totally 40 minutes.
Although known to be a path to ultra-high resolution and sensitivity, PLOT columns have hardly been used in LC-MS (notable exceptions are described in references [31]–[36]) much due to incompatibilities with commercial LC instrumentation and detectors. These issues are to a large degree resolved [31], [35]. In addition to high LC performance, PLOT columns are simple to manufacture, with a high degree of reproducibility [34], [36].
We here describe a further developed OTER-PLOT system that enables fast enzyme cleavage and selective detection of target proteins in biological samples. The OTERs have been improved by e.g. increasing reactor length (volume) and immobilizing with a combination of trypsin and Lys-C, and the system is now fully automated, using commercial LC-MS instrumentation and software. By utilizing the narrow bore 10 µm ID PLOT columns, high sensitivity is achieved, which is important for detecting proteins present at low concentrations in samples of limited availability. The system performance is demonstrated by detecting targeted Wnt-pathway proteins from cell lines and xenograft tissues.
Materials and Methods
Chemicals, reagents and materials
All chemicals, reagents and materials were obtained from commercial sources and chemicals/reagents were of analytical grade. See Chemicals, reagents and materials S1 in File S1, for more details.
OTER preparation
For a visual description of the production of the OTERs, see Video S1. Figure S1 in File S1 illustrates the reaction chemistry of the OTER. In short; the wall-polymerization solution consisting of 0.08 g HEMA, 0.02 g VDM, 0.60 g 1-heptanol and 0.0001 g AIBN, was filled into a 20 µm ID pre-treated fused silica capillary using an in-house made pressure bomb, and the capillary ends were sealed by sticking the ends into septa (originally intended for use in gas chromatography (GC) injection systems). The polymerization was performed in an oven (originally intended for GC column heating) at 65°C for 5 hours, followed by 80°C for 5 hours. The polymerized capillary was dried with nitrogen for 30 min. Immobilization was performed by flushing the column with the appropriate enzyme solution (trypsin: 2.5 mg/mL trypsin and 0.25 mg/mL benzamidine, Lys-C; 5–15 µg/mL Lys-C and 0.5–1.5 µg/mL benzamidine, Trypsin/Lys-C mix; 20 µg/mLTrypsin/Lys-C and 0.2 µg/mL benzamidine, solved in 20 mM phosphate buffer, pH 7.4) for 3 hours. The OTER was subsequently filled with 50 mM ammonium acetate, pH 6–7 and stored at 4°C.
For detailed description of production of the pre-columns and polystyrene divinylbenzene (PS-DVB) PLOT LC columns (previously described in [37]) see Methods S1 in File S1.
OTER-PLOT system set-up
The manual OTER-PLOT system is described in detail elsewhere [37] and in Methods S2 File S1. For the automated set-up (see Figure 1 and Animation S1) an Easy nLC1000 (Thermo Fisher Scientific, Bremen, Germany) pump was used for injection, column equilibration and gradient elution. Mobile phase A (MP A) contained 4% ACN in 0.1% FA, whereas MP B contained 0.1% FA in ACN. To incorporate the enzymatic reactor to the Easy nLC1000 pump, two automatic port switching valves were added; one Rheodyne 6-port valve (V1, Figure 1, IDEX Health & Science LLC, Rohnert Park, CA, USA) and one 10-port valve (V2, shown as a 6-port in Figure 1, VICI, Valco Instruments Co. Inc., Houston, TX, USA), both connected to the MS contact closure outputs and controlled by the MS instrument software. Note that valve V2 may be replaced with a 6-port valve and is illustrated as such for simplicity. Fused silica tubing (20 µm ID) was used between valves S, V1 and V2.
Five µL sample were loaded onto the injection loop, and an appropriate volume was loaded onto the OTER (4 meter (∼1.2 µL) connected using PicoClear unions (New Objective, Woburn, MA, USA)) at a flow rate of 0.5 µL/min (V1 with connecting ports 1 and 2 and V2 connecting ports 1 and 6). The OTER was conveniently placed inside a column oven (Mistral, Spark Holland) at 37°C. After loading, V1 was switched; connecting ports 1 and 6 and the tubing was flushed for 5 minutes with 100% MP A while the autosampler loop was flushed with 4% ACN in 50 mM ammonium acetate. V2 was switched, connecting ports 1 and 6 and the pre-column and PLOT column were equilibrated for 55 minutes at 40 nL/min. 2 µL 4% ACN in 50 mM ammonium acetate eluted the generated peptides from the OTER and onto the 50 µm ID x 4 cm butyl-methacrylate (BuMa) monolithic pre-column, with valve W connecting ports 1 and 2, for 4 minutes at 0.5 µL/min. The pre-column was used to trap and desalt the peptides. The flow was split to 40 nL/min by switching valve W to connect ports 1 and 6, and peptides were separated using a linear gradient from 0–40% MP B in 40 minutes, with a subsequent linear step up to 95% MP B in 10 minutes and kept at 95% MP B for 10 minutes, on a 10 µm ID x 500 cm long PS-DVB-PLOT column.
For analysis of pre-digested samples, valves V1 and V2 were set in the position connecting ports 1 and 6, and ports 1 and 2, respectively, and 1 µL sample was loaded onto the pre-column for 4 minutes at a flow-rate of 0.5 µL/min, with subsequent separation of peptides on the PS-DVB PLOT column.
For the comprehensive set-up, gradient elution was performed from 0–40% MP B in 250 minutes, with a linear increase to 95% MP B in 10 minutes and wash at 95% MP B for 20 minutes. For targeted investigations, linear gradient elution was performed for 40 minutes from 0–40% MP B, with a linear increase for 10 minutes to 95% MP B and a hold at 95% MP B for 10 minutes. The PLOT column was connected to a Q-Exactive Mass Spectrometer (Thermo Fisher Scientific) equipped with a 10 µm ID to 5±1 µm nanospray ESI-emitter (PicoTip, New Objective), with an applied voltage of 1.3 kV and capillary temperature of 250°C. The system could just as easily be connected to other mass spectrometers. e.g. a triple quadrupole MS for quantitative multiple reaction monitoring (MRM).
Mass spectrometry
For data-dependent acquisition the full MS scan range was set to m/z 350–1850 and the 12 most intense ions were selected for fragmentation. The full MS resolution was 70,000 with an automatic gain control (AGC) target value of 1e6 and maximum fill time of 120 ms. The MS/MS resolution was set to 35,000 with AGC target value of 1e5 and maximum fill time of 120 ms. The ions were fragmented with a normalized collision energy (NCE) of 25, isolation width of m/z 2.0 and only ions with charge +2 - +6 were selected for fragmentation. The dynamic exclusion was set to 30 seconds. The Easy nLC1000 and Q-Exactive Orbitrap were controlled by Xcalibur software (v2.2, Thermo Fisher Scientific).
For preparation of the standard solutions, HCT15 cell lysate, tumor tissue and database search, see Methods S3 and S4 in File S1. A list of identified proteins can be found in Table S1. Other raw files and spreadsheets are available at http://www.mn.uio.no/kjemi/supplementary-data/bach/Open-tubular-lab-on-column-mass-spectrometry-for-targe/. In the unexpected event of web relocation of the raw data files, we will provide the new web address in the comments section of the online version of this paper.
Ethics statement
The tumor tissue samples were from 6 week old female CB17 SCID mice xenografted with HCT15 cells that were treated with tankyrase inhibitor G007-LK, which was administered at 10 mg/kg daily (study described in Lau et al [38]). All animal experiments were approved by the Norwegian Animal Research Authority (NARA) and were carried out following accepted ethical standards. The experiments/procedures have thus been conducted in accordance with the laws and regulations controlling experiments/procedures of live animals in Norway, i.e. the Animal Welfare Act of December 20th 1974, No 73, chapter VI sections 20–22 and the Regulation on Animal Experimentation of January 15th 1996. In addition, Norway has signed and ratified The European Convention for the protection of Vertebrate Animals used for Experimental and other Scientific Purposes of March 18th 1986. The Norwegian legislation conforms in all respects with the basic requirements of this Convention and guidelines prepared in pursuance of it. All efforts were made to minimize the number and suffering of animals.
For details regarding the preparation of these samples, see Methods S3.4 in File S1.
Results and Discussion
In order to further develop the prototype OTER-PLOT-LC-MS [37] into an applicable platform, several improvements were needed regarding the OTER and automation of the platform.
OTER features and characteristics
In a narrow bore open format, open tubular enzyme reactors (OTERs) have been found to be easy to repeatedly prepare and with less backpressure (and thus short preparation times when filling reagents into capillaries with the pressure bomb) compared to monolithic and packed reactors [39]–[43]. To increase the effective surface area compared to previous efforts ([37]), longer reactors need to be used [44]. Increasing the reactor volume also allows for exploiting more of the available small sample. Changing the porogenic solvent in the polymerization solution from 1-decanol (used in [37] based on procedures described in reference [45]) to 1-heptanol, reactors of 1 meter (∼300 nL volume) were easily produced. A scanning electron microscope (SEM) image of the inside of an OTER can be seen in Figure 2; a thin polymeric layer of ∼0.4 µm (dry) with evenly spread globules make up the anchoring phase for the proteolytic enzymes.
Trypsin is the most used proteolytic enzyme for the conversion of proteins to peptides, also in micro scale IMERs. Only a few IMERs are reported immobilized with other enzymes such as Lys-C, pepsin, PNGase F, proteinase K and chymotrypsin [30], [44]. Choosing a combination of trypsin and Lys-C, which is often used in off-line digestion can provide a more complete digestion of proteins by reducing the number of missed cleavage sites, enabling improved repeatability and accuracy [46]. In initial investigations of reactor performance Lys-C, trypsin and Trypsin/Lys-C mix, were immobilized onto short 20 µm ID (∼60 nL) polymerized reactors and observed digestion of a standard protein, cytochrome C (commonly used to evaluate IMERs) was used for measuring reactor efficiency. The Trypsin/Lys-C reactor gave a 30% increase in cleaved protein, outperforming the Lys-C-only and trypsin-only immobilized reactors. With a reactor volume of ∼60 nL, only 2 out of 10 proteins in a standard mix were digested, but by increasing the length (and hence the volume) of the reactor 5-fold (∼300 nL), 10 out of the 10 proteins could be identified (Figure 3). A reactor digestion temperature of 50°C resulted in higher sequence coverage and more identified standard proteins compared to 22 and 37°C (Figure S2 in File S1). However, a reactor temperature of 50°C was associated with poor performance (less identified proteins) when longer (up to 2 h) digestion times were evaluated (Figure S3 in File S1), thus digestion at 37°C was chosen as it provided far more robust performance. As a compromise between time and throughput, 1 hour digestion time was chosen for the on-line analysis of the cell lysate and tumor xenograft samples. The reactors showed good repeatability of performance when three 1 meter (∼300 nL) individually prepared OTERs were used for digestion of the 10 protein standard mix (Figure 3).
The complementary combination of trypsin and Lys-C has, as already mentioned, been investigated in several off-line experiments, but to the authors' knowledge for the first time been exploited in the open tubular IMER format with a reactor volume that makes them very suitable for analysis of small samples.
A fully automated nanoproteomic platform
Automated systems are usually required for high-throughput analysis. On-line protein digestion (with integrated OTER) and subsequent peptide separation (PLOT column) was performed with a fully automated platform using a commercial nLC system, with minimum dead volumes and low backpressures (<400 bar). A schematic overview of the platform is presented in Figure 4. Figure 1 (and Animation S1) provides a detailed description of the plumbing and valve positions of the platform.
Although other sensitive nanoflow columns in somewhat larger formats exists, e.g. 25 µm ID packed columns for peptide separations [47], PLOT LC columns are associated with good column-to-column production repeatability together with high performance and little carry-over [31], [34] and are well adapted to be coupled on-line to enzyme reactors [37].
Figure 5 shows that chromatographic peaks can be very narrow using the automated OTER-PLOT platform (typical peak widths W0.1 are ∼6 seconds). Conveniently, the system set-up can be programmed to perform both conventional LC-MS (i.e. analysis of pre-digested samples) and OTER-PLOT performance, without any hardware changes. Figure 6 A and B show that peak shapes, retention times and peak widths obtained in traditional off-line digestion mode and OTER-PLOT mode are very similar (evaluated with signature peptides that were easily produced with both in-solution digestion and OTER), which is a testament to the robustness of the automated OTER-PLOT platform.
The OTER-PLOT run time including both protein digestion and LC-MS processing was typically 240 min (1 h digestion, 150 min LC run time) in comprehensive mode and 120 min (1 h digestion and 60 min LC run time) in targeted mode (which is our current main focus). However, these run times can be shorted and lengthened for faster analysis or higher peak capacities, respectively. All samples analysed in the platform were reduced and alkylated in advance, but as Kim et al. suggest this step might be avoided due to the enhanced rate of proteolysis that is provided by IMERs, that in many cases allows direct digestion of proteins without reduction and alkylation.
The platform carry-over was generally not detectable (Figure 7), but it should be mentioned that in rare cases up to 2.5% carry-over could be observed for certain peptides, when injecting very high concentrations of standard protein mix (300 µg/mL).
The platform, being automated and consisting of both integrated protein digestion and chromatographic separation in narrow open tubular columns is unique in its field today. Others have described related set-ups (using larger bore packed/monolithic columns), but none with e.g. a fully integrated IMER and simple commercial instrumentation. Kim et al. describe a semi-automatic system for reducing digestion time [48], but the IMER was not connected to the LC-MS system due to reproducibility considerations. Sproß et al. describe a fully automated on-line 3D nano-HPLC/nano-ESI-Q-TOF-MS/MS system composed of a monolithic trypsin reactor in the first dimension, a monolithic affinity column in the second dimension, and C18 HPLC-Chip in the third dimension [49], requiring 4 high performance pumps. In contrast, the OTER-PLOT platform requires only one nanoLC pump with two additional valves that are easily controlled by the MS software.
Platform demonstration
Targeted proteomics
To consider the potential of OTER-PLOT for targeting diagnostic markers, the system must feature high sensitivity and selectivity for the targets in complex samples. In this context, Axin1 and adenomatous polyposis coli (APC) were monitored in biological samples by the OTER-PLOT set-up; Axin1 (96 kDa) and APC (311 kDa) are low abundant, house-keeping proteins of the Wnt-pathway, regulating proteasomal degradation of β-catenin [50], [51]. Several studies have shown that mutations/alterations in either of these two proteins can lead to development of colorectal cancer [52]. Additionally, the levels of both Axin1 and APC have been reported as potential markers for colorectal cancer [53]–[57].
Using high resolution Orbitrap-MS (well suited to selectively target low abundant peptides in the presence of a complex background [58]) with the OTER-PLOT platform, Axin1 was detected in a colon cancer cell (HCT15) lysate within two hours per sample (Figure 6A), with protein identification supported by matching retention time/mass spectra with an external standard. The retention time of the proteotypic Axin1 peptide varied less than 4% between the standard and the complex sample. Combined with the fragmentation mass spectra (Figure S4 A in File S1) the selectivity of this automated assay is high.
Similarly, the platform can be used to detect target proteins in tumor samples, identifying APC in an HCT15 based-tumor (mouse xenograft model) as well as its parent cell line; Figure 6B shows the extracted ion chromatogram (EIC) of a proteotypic peptide from a total protein extract prepared from HCT15 originating tumor tissue and HCT15 cells, using the OTER-PLOT platform. In the present study tumor sample of 500 ng (protein extract) was used for analysis and sufficient to detect APC. Importantly, the OTER-PLOT assay is not susceptible to the mass limitations in WB or antibody selectivity issues, as has been demonstrated for APC.
Very narrow open tubular columns should be particularly well suited for handling limited samples; Indeed, the target protein Axin1 could be unambiguously detected (with target peptides easily produced when using OTER) when introducing just 10 ng of sample to the OTER (corresponding to HCT15 cell protein extract from ∼1,000 cells, see experimental section and Methods S3.3 in File S1) (Figure 8), demonstrating the high sensitivity and small sample capability of the platform.
Although the platform was found to have low carry-over, blank injections were routinely performed and evaluated before sample injections.
Comprehensive proteomics
Even though our primarily goal was to use the OTER-PLOT platform for targeted determinations, it could also be applied for comprehensive analysis. In a single run using a relatively short gradient program (150 min), 1462 proteins were identified in a protein extract (500 ng total protein extract) from HCT15 cells with high peptide confidence, FDR: 0.01 (Figure 9; see also http://www.mn.uio.no/kjemi/supplementary-data/bach/Open-tubular-lab-on-column-mass-spectrometry-for-targe/for raw files and Table S1 for list of identified proteins).
This is a significant improvement compared to similar approaches with integrated IMERs [44] reporting between 78 and 541 proteins identified from much higher amounts of sample digested on-line (e.g. 2.0–2.4 µg [59], [60]); Sun et al reported ∼220 protein IDs when working with similar protein amounts, employing off-line immobilized trypsin digestion [61]. Other central Wnt-pathway proteins were readily identified in the comprehensive mode; such as β-catenin, low density lipoprotein receptor-related protein 6 (LRP5/6), disheveled segment polarity protein 1 (DVL), and casein kinase 2 (CK2), showing that untargeted OTER-PLOT can provide useful complementary information within reasonable time.
Conclusion
A fully automated open tubular-based nanoproteomic platform, utilizing commercially available instrumentation and equipment, has successfully been developed for sensitive on-line digestion/detection of targeted proteins in biological samples of limited sizes (e.g. ∼1,000 cells). With this workflow, low abundant targets can be monitored in a few hours from sample collection to data analysis. Although, the novel OTER-PLOT platform already performs at a high level, we expect it to have even higher output/selectivity following further optimizations (regarding e.g. column polymer chemistry, column dimensions, affinity column add-ons etc.).
Supporting Information
Acknowledgments
The authors would like to thank: Mr. Inge Mikalsen for contributing to the column production set-up, Mrs. Dorna Misaghian for performing preliminary experiments and Dr. Jo Waaler for tumor tissue samples.
Data Availability
The authors confirm that all data underlying the findings are fully available without restriction. All relevant data are within the paper and its Supporting Information files. Larger raw files are found at http://www.mn.uio.no/kjemi/supplementary-data/bach/Open-tubular-lab-on-column-mass-spectrometry-for-targe/
Funding Statement
This work was funded by the University of Oslo, SFI-CAST and the Norwegian Research Council. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
References
- 1. Koomen JM, Haura EB, Bepler G, Sutphen R, Remily-Wood ER, et al. (2008) Proteomic contributions to personalized cancer care. Mol Cell Proteomics 7: 1780–1794. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2. Leung F, Musrap N, Diamandis EP, Kulasingam V (2013) Advances in mass spectrometry-based technologies to direct personalized medicine in ovarian cancer. Trans Proteomics 1: 74–86. [Google Scholar]
- 3. Compton C (2014) Data quality and personalized medicine. OE 13: 13–15. [Google Scholar]
- 4. Cooperberg MR, Simko JP, Cowan JE, Reid JE, Djalilvand A, et al. (2013) Validation of a cell-cycle progression gene panel to improve risk stratification in a contemporary prostatectomy cohort. J Clin Oncol 31: 1428–1434. [DOI] [PubMed] [Google Scholar]
- 5.Maak M, Simon I, Nitsche U, Roepman P, Snel M, et al.. (2013) Independent Validation of a Prognostic Genomic Signature (ColoPrint) for Patients With Stage II Colon Cancer. Ann Surg 257: 1053–1058 1010.1097/SLA.1050b1013e31827c31180. [DOI] [PubMed]
- 6. Sveen A, Agesen TH, Nesbakken A, Meling GI, Rognum TO, et al. (2012) ColoGuidePro: a prognostic 7-gene expression signature for stage III colorectal cancer patients. Clin Cancer Res 18: 6001–6010. [DOI] [PubMed] [Google Scholar]
- 7. van 't Veer LJ, Dai H, van de Vijver MJ, He YD, Hart AAM, et al. (2002) Gene expression profiling predicts clinical outcome of breast cancer. Nature 415: 530–536. [DOI] [PubMed] [Google Scholar]
- 8. Guo Y, Xiao P, Lei S, Deng F, Xiao GG, et al. (2008) How is mRNA expression predictive for protein expression? A correlation study on human circulating monocytes. Acta Biochim Biophys Sin (Shanghai) 40: 426–436. [DOI] [PubMed] [Google Scholar]
- 9. Schwanhausser B, Busse D, Li N, Dittmar G, Schuchhardt J, et al. (2011) Global quantification of mammalian gene expression control. Nature 473: 337–342. [DOI] [PubMed] [Google Scholar]
- 10. Mayne J, Starr AE, Ning Z, Chen R, Chiang CK, et al. (2014) Fine tuning of proteomic technologies to improve biological findings: advancements in 2011-2013. Anal Chem 86: 176–195. [DOI] [PubMed] [Google Scholar]
- 11. Aebersold R, Burlingame AL, Bradshaw RA (2013) Western blots versus selected reaction monitoring assays: time to turn the tables? Mol Cell Proteomics 12: 2381–2382. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12. Picotti P, Aebersold R (2012) Selected reaction monitoring-based proteomics: workflows, potential, pitfalls and future directions. Nat Methods 9: 555–566. [DOI] [PubMed] [Google Scholar]
- 13. Xie F, Liu T, Qian WJ, Petyuk VA, Smith RD (2011) Liquid chromatography-mass spectrometry-based quantitative proteomics. J Biol Chem 286: 25443–25449. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14. Nilsson T, Mann M, Aebersold R, Yates JR, Bairoch A, et al. (2010) Mass spectrometry in high-throughput proteomics: ready for the big time. Nat Meth 7: 681–685. [DOI] [PubMed] [Google Scholar]
- 15.Azkargorta M, Wojtas MN, Abrescia NG, Elortza F (2014) Lysine Methylation Mapping of Crenarchaeal DNA-Directed RNA Polymerases by Collision-Induced and Electron-Transfer Dissociation Mass Spectrometry. J Proteome Res. [DOI] [PubMed]
- 16. Chen C, Liu X, Zheng W, Zhang L, Yao J, et al. (2014) Screening of missing proteins in the human liver proteome by improved MRM-approach-based targeted proteomics. J Proteome Res 13: 1969–1978. [DOI] [PubMed] [Google Scholar]
- 17. D'Aguanno S, Barcaroli D, Rossi C, Zucchelli M, Ciavardelli D, et al. (2014) p63 isoforms regulate metabolism of cancer stem cells. J Proteome Res 13: 2120–2136. [DOI] [PubMed] [Google Scholar]
- 18. da Fonseca Pires S, Fialho LC Jr, Silva SO, Melo MN, de Souza CC, et al. (2014) Identification of virulence factors in leishmania infantum strains by a proteomic approach. J Proteome Res 13: 1860–1872. [DOI] [PubMed] [Google Scholar]
- 19.Lv DW, Ge P, Zhang M, Cheng ZW, Li XH, et al.. (2014) Integrative Network Analysis of the Signaling Cascades in Seedling Leaves of Bread Wheat by Large-Scale Phosphoproteomic Profiling. J Proteome Res. [DOI] [PubMed]
- 20. Musunuri S, Wetterhall M, Ingelsson M, Lannfelt L, Artemenko K, et al. (2014) Quantification of the brain proteome in Alzheimer's disease using multiplexed mass spectrometry. J Proteome Res 13: 2056–2068. [DOI] [PubMed] [Google Scholar]
- 21. Nolte H, Konzer A, Ruhs A, Jungblut B, Braun T, et al. (2014) Global protein expression profiling of zebrafish organs based on in vivo incorporation of stable isotopes. J Proteome Res 13: 2162–2174. [DOI] [PubMed] [Google Scholar]
- 22.Poschmann G, Seyfarth K, Besong Agbo D, Klafki HW, Rozman J, et al.. (2014) High-Fat Diet Induced Isoform Changes of the Parkinson's Disease Protein DJ-1. J Proteome Res. [DOI] [PubMed]
- 23.Zhao X, Bak S, Pedersen AJ, Jensen ON, Hojlund K (2014) Insulin Increases Phosphorylation of Mitochondrial Proteins in Human Skeletal Muscle in Vivo. J Proteome Res. [DOI] [PubMed]
- 24. Zhao X, Sidoli S, Wang L, Wang W, Guo L, et al. (2014) Comparative proteomic analysis of histone post-translational modifications upon ischemia/reperfusion-induced retinal injury. J Proteome Res 13: 2175–2186. [DOI] [PubMed] [Google Scholar]
- 25. Nunez O, Nakanishi K, Tanaka N (2008) Preparation of monolithic silica columns for high-performance liquid chromatography. J Chromatogr A 1191: 231–252. [DOI] [PubMed] [Google Scholar]
- 26. Svec F (2004) Preparation and HPLC applications of rigid macroporous organic polymer monoliths. J Sep Sci 27: 747–766. [DOI] [PubMed] [Google Scholar]
- 27.Schappler J, Rudaz S, Veuthey JL, Guillarme D (2013) Coupling UHPLC with MS: The Needs, Challenges, and Applications. Ultra-High Performance Liquid Chromatography and its Applications: John Wiley & Sons, Inc. pp. 95–131.
- 28.Fekete S, Fekete J (2013) The Potential of Shell Particles in Fast Liquid Chromatography. Ultra-High Performance Liquid Chromatography and its Applications: John Wiley & Sons, Inc. pp. 133–167.
- 29. Massolini G, Calleri E (2005) Immobilized trypsin systems coupled on-line to separation methods: recent developments and analytical applications. J Sep Sci 28: 7–21. [DOI] [PubMed] [Google Scholar]
- 30. Yamaguchi H, Miyazaki M (2013) Enzyme-immobilized reactors for rapid and efficient sample preparation in MS-based proteomic studies. PROTEOMICS 13: 457–466. [DOI] [PubMed] [Google Scholar]
- 31. Rogeberg M, Vehus T, Grutle L, Greibrokk T, Wilson SR, et al. (2013) Separation optimization of long porous-layer open-tubular columns for nano-LC-MS of limited proteomic samples. J Sep Sci 36: 2838–2847. [DOI] [PubMed] [Google Scholar]
- 32. Luo Q, Gu Y, Wu SL, Rejtar T, Karger BL (2008) Two-dimensional strong cation exchange/porous layer open tubular/mass spectrometry for ultratrace proteomic analysis using a 10 microm id poly(styrene- divinylbenzene) porous layer open tubular column with an on-line triphasic trapping column. Electrophoresis 29: 1604–1611. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33. Luo Q, Yue G, Valaskovic GA, Gu Y, Wu SL, et al. (2007) On-line 1D and 2D porous layer open tubular/LC-ESI-MS using 10-microm-i.d. poly(styrene-divinylbenzene) columns for ultrasensitive proteomic analysis. Anal Chem 79: 6174–6181. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34. Rogeberg M, Wilson SR, Greibrokk T, Lundanes E (2010) Separation of intact proteins on porous layer open tubular (PLOT) columns. J Chromatogr A 1217: 2782–2786. [DOI] [PubMed] [Google Scholar]
- 35. Thakur D, Rejtar T, Wang D, Bones J, Cha S, et al. (2011) Microproteomic analysis of 10,000 laser captured microdissected breast tumor cells using short-range sodium dodecyl sulfate-polyacrylamide gel electrophoresis and porous layer open tubular liquid chromatography tandem mass spectrometry. J Chromatogr A 1218: 8168–8174. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36. Yue G, Luo Q, Zhang J, Wu SL, Karger BL (2007) Ultratrace LC/MS proteomic analysis using 10-microm-i.d. Porous layer open tubular poly(styrene-divinylbenzene) capillary columns. Anal Chem 79: 938–946. [DOI] [PubMed] [Google Scholar]
- 37. Hustoft HK, Brandtzaeg OK, Rogeberg M, Misaghian D, Torsetnes SB, et al. (2013) Integrated enzyme reactor and high resolving chromatography in "sub-chip" dimensions for sensitive protein mass spectrometry. Sci Rep 3: 3511. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38. Lau T, Chan E, Callow M, Waaler J, Boggs J, et al. (2013) A Novel Tankyrase Small-Molecule Inhibitor Suppresses APC Mutation–Driven Colorectal Tumor Growth. Cancer Res 73: 3132–3144. [DOI] [PubMed] [Google Scholar]
- 39. Abele S, Smejkal P, Yavorska O, Foret F, Macka M (2010) Evanescent wave-initiated photopolymerisation as a new way to create monolithic open-tubular capillary columns: use as enzymatic microreactor for on-line protein digestion. Analyst 135: 477–481. [DOI] [PubMed] [Google Scholar]
- 40. Amankwa LN, Kuhr WG (1992) Trypsin-Modified Fused-Silica Capillary Microreactor for Peptide-Mapping by Capillary Zone Electrophoresis. Anal Chem 64: 1610–1613. [Google Scholar]
- 41. Hu JW, Shen YH, Qin WJ, Zhang YJ, Qian XH (2012) Preparation of Multi-layer Open Capillary Immobilized Enzyme Reactor and Its Application in Digestion of Proteins. Chem J Chin U 33: 268–275. [Google Scholar]
- 42. Licklider L, Kuhr WG (1994) Optimization of Online Peptide-Mapping by Capillary Zone Electrophoresis. Anal Chem 66: 4400–4407. [Google Scholar]
- 43. Stigter EC, de Jong GJ, van Bennekom WP (2007) Development of an open-tubular trypsin reactor for on-line digestion of proteins. Anal Bioanal Chem 389: 1967–1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44. Safdar M, Spross J, Janis J (2014) Microscale immobilized enzyme reactors in proteomics: latest developments. J Chromatogr A 1324: 1–10. [DOI] [PubMed] [Google Scholar]
- 45. Huang T, Mi JQ, Zhang XX (2006) Capillary electrochromatography of amino acids with a protein-bonded porous-layer open-tubular column. J Sep Sci 29: 277–281. [DOI] [PubMed] [Google Scholar]
- 46.Promega (2014) Trypsin/Lys-C Mix.
- 47.Kocher T, Pichler P, Pra MD, Rieux L, Swart R, et al.. (2014) Development and performance evaluation of an ultra-low flow nano liquid chromatography-tandem mass spectrometry set-up. PROTEOMICS: n/a-n/a. [DOI] [PubMed]
- 48. Kim JH, Inerowicz D, Hedrick V, Regnier F (2013) Integrated sample preparation methodology for proteomics: analysis of native proteins. Anal Chem 85: 8039–8045. [DOI] [PubMed] [Google Scholar]
- 49. Sproß J, Brauch S, Mandel F, Wagner M, Buckenmaier S, et al. (2013) Multidimensional nano-HPLC coupled with tandem mass spectrometry for analyzing biotinylated proteins. Anal Bioanal Chem 405: 2163–2173. [DOI] [PubMed] [Google Scholar]
- 50. MacDonald BT, Tamai K, He X (2009) Wnt/beta-catenin signaling: components, mechanisms, and diseases. Dev Cell 17: 9–26. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51. Wang M, Weiss M, Simonovic M, Haertinger G, Schrimpf SP, et al. (2012) PaxDb, a Database of Protein Abundance Averages Across All Three Domains of Life. Molecular & Cellular Proteomics 11: 492–500. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52. Miyaki M, Konishi M, Kikuchi-Yanoshita R, Enomoto M, Igari T, et al. (1994) Characteristics of somatic mutation of the adenomatous polyposis coli gene in colorectal tumors. Cancer Res 54: 3011–3020. [PubMed] [Google Scholar]
- 53. Neufeld KL, Zhang F, Cullen BR, White RL (2000) APC-mediated downregulation of beta-catenin activity involves nuclear sequestration and nuclear export. EMBO Rep 1: 519–523. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54. Henderson BR, Fagotto F (2002) The ins and outs of APC and beta-catenin nuclear transport. EMBO Rep 3: 834–839. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55. Li VS, Ng SS, Boersema PJ, Low TY, Karthaus WR, et al. (2012) Wnt signaling through inhibition of beta-catenin degradation in an intact Axin1 complex. Cell 149: 1245–1256. [DOI] [PubMed] [Google Scholar]
- 56. Serafino A, Moroni N, Zonfrillo M, Andreola F, Mercuri L, et al. (2014) WNT-pathway components as predictive markers useful for diagnosis, prevention and therapy in inflammatory bowel disease and sporadic colorectal cancer. Oncotarget 5: 978–992. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57. Nasir A, Lopez A, Boulware D, Malafa M, Coppola D (2011) Correlation between COX-2 and APC Expression in Left Versus Right-sided Human Colon Cancer. Anticancer Res 31: 2191–2195. [PubMed] [Google Scholar]
- 58. Gallien S, Duriez E, Crone C, Kellmann M, Moehring T, et al. (2012) Targeted proteomic quantification on quadrupole-orbitrap mass spectrometer. Mol Cell Proteomics 11: 1709–1723. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59. Wang T, Ma J, Wu S, Yuan H, Zhang L, et al. (2011) Integrated platform of capillary isoelectric focusing, trypsin immobilized enzyme microreactor and nanoreversed-phase liquid chromatography with mass spectrometry for online protein profiling. Electrophoresis 32: 2848–2856. [DOI] [PubMed] [Google Scholar]
- 60. Jiang H, Yuan H, Liang Y, Xia S, Zhao Q, et al. (2012) A hydrophilic immobilized trypsin reactor with N-vinyl-2-pyrrolidinone modified polymer microparticles as matrix for highly efficient protein digestion with low peptide residue. J Chromatogr A 1246: 111–116. [DOI] [PubMed] [Google Scholar]
- 61. Sun L, Zhu G, Li Y, Yang P, Dovichi NJ (2012) Coupling methanol denaturation, immobilized trypsin digestion, and accurate mass and time tagging for liquid-chromatography-based shotgun proteomics of low nanogram amounts of RAW 264.7 cell lysate. Anal Chem 84: 8715–8721. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The authors confirm that all data underlying the findings are fully available without restriction. All relevant data are within the paper and its Supporting Information files. Larger raw files are found at http://www.mn.uio.no/kjemi/supplementary-data/bach/Open-tubular-lab-on-column-mass-spectrometry-for-targe/