Abstract
To facilitate therapeutic monitoring of antiepileptic drugs (AEDs) by healthcare professionals for patients with epilepsy (PWE), we applied a GC-MS assay to measure three AEDs: carbamazepine (CBZ), phenytoin (PHT) and valproic acid (VPA) levels concurrently in one dried blood spot (DBS), and validated the DBS-measured levels to their plasma levels. 169 PWE on either mono- or polytherapy of CBZ, PHT or/and VPA were included. One DBS, containing ∼15 µL of blood, was acquired for the simultaneous measurement of the drug levels using GC-MS. Simple Deming regressions were performed to correlate the DBS levels with the plasma levels determined by the conventional immunoturbimetric assay in clinical practice. Statistical analyses of the results were done using MedCalc Version 12.6.1.0 and SPSS 21. DBS concentrations (Cdbs) were well-correlated to the plasma concentrations (Cplasma): r = 0.8381, 0.9305 and 0.8531 for CBZ, PHT and VPA respectively, The conversion formulas from Cdbs to plasma concentrations were [0.89×CdbsCBZ+1.00]µg/mL, [1.11×CdbsPHT−1.00]µg/mL and [0.92×CdbsVPA+12.48]µg/mL respectively. Inclusion of the red blood cells (RBC)/plasma partition ratio (K) and the individual hematocrit levels in the estimation of the theoretical Cplasma from Cdbs of PHT and VPA further improved the identity between the observed and the estimated theoretical Cplasma. Bland-Altman plots indicated that the theoretical and observed Cplasma of PHT and VPA agreed well, and >93.0% of concentrations was within 95% CI (±2SD); and similar agreement (1∶1) was also found between the observed Cdbs and Cplasma of CBZ. As the Cplasma of CBZ, PHT and VPA can be accurately estimated from their Cdbs, DBS can therefore be used for drug monitoring in PWE on any of these AEDs.
Introduction
Epilepsy is a neurological disease that requires chronic treatment with antiepileptic drugs (AEDs). To date, the most commonly used AEDs are still carbamazepine (CBZ), phenytoin (PHT) and valproic acid (VPA). These drugs have maximum efficacy and minimum toxicity when their plasma drug levels are within their therapeutic indexes. Hence, routine plasma concentration monitoring is recommended especially during dose adjustments, for compliance check and/or for adverse drug reaction investigation [1]. In current practice, monitoring of plasma AEDs is done using the immunoturbidimetric assay for each individual drug. In this assay, the drug of interest complexes with its specific antibody and becomes insoluble. The turbidity generated from the immune complexes corresponds to the drug concentration in sample and is then measured spectrophotometrically. However, for this assay, there is always a risk that the antibody could cross-react with the metabolites of the drug. This could result in overestimation of the plasma concentrations. During the course of AEDs therapy, approximately 40% to 50% of people with epilepsy (PWE) will require two or more antiepileptic drugs (AEDs) at one point of their therapy [2]–[4]. Attempts have therefore been made to monitor a few AEDs levels simultaneously [5]–[7], with the objective to reduce the workload of the hospital laboratories and the TDM cost borne by the patients.
Various biological matrices including cerebrospinal fluid, tear and saliva have been used for TDM [8]–[10]. In comparison with DBS as the matrix, the acquisition of blood spot is simple, and does not require the aid of phlebotomist. DBS entails small sampling volume (<100 µL) and can be acquired by patients or their caregivers at home. After drying, it can be mailed to the designated laboratory [11], [12]. The patients will be able to save their travelling time to the clinics for submitting their TDM samples. The only caveat for DBS acquisition seems to be the patients’ acceptability for the needle-prick.
Earlier studies on concurrent monitoring of multiple AEDs from one DBS were done mostly with high performance liquid chromatography (HPLC) and included whole blood concentrations of AEDs such as carbamazepine, phenytoin, lamotrigine and barbiturates with limited clinical validation [13], [14]. Recently, a group in North Ireland published a detailed HPLC ultraviolet method for concurrent determination of carbamazepine (CBZ) and its active metabolite carbamazepine-10,11 epoxide (CBZE), levetiracetam (LEV), lamotrigine (LTG) and phenobarbital (PHB) in DBS of children [15]. Similarly, they did not establish the correlations between the DBS and plasma concentrations of the AEDs involved.
In our population of PWE, CBZ, sodium valproate (VPA) and phenytoin (PHT) are the most popular antiepileptic drugs (AEDs) - used either as mono or polytherapy [4]. This has prompted us to investigate the applicability of monitoring all three AEDs using only one DBS. Considering the volatile nature of VPA and previous success in quantitation of CBZ and PHT using gas chromatography mass spectrometry (GCMS) [16], GCMS was ultimately chosen as the analytical tool for simultaneous determination of these AEDs. This study was conducted with the main objective of comparing the newly developed GCMS assay with the conventional immunoturbimetric assays. The DBS-measured concentrations were validated against their corresponding plasma concentrations as determined by the immunoturbimetric assays performed in hospital laboratory. Since plasma-to-RBC drug partitioning effect in relation to the hematocrit level is known to influence the degree of correspondence between plasma and full blood concentration of AEDs, this effect was also investigated in our study.
Methods
This study has obtained approval from the SingHealth Institutional Review Board (CIRB No. 2011/269/A). Only PWE who had routine plasma CBZ, VPA and/or PHT, blood and liver biochemistry monitoring on the day of visit were approached for written consent prior to blood sampling.
Patient Recruitment
Assuming constant analytical standard deviations, the sample size recommended for method validation was suggested to be at least 41 per AED based on the following information: range ratio = 2, α = 5%, power = 90%, standardized slope deviation of 4 [17], [18]. PWE who were on either CBZ, VPA or/and PHT were recruited from October 2011 to August 2012 at neurology specialist clinic of a tertiary referral hospital. This study had obtained the local ethics committee approval. Only PWE who had routine plasma CBZ, PHT and/or VPA, blood and liver biochemistries monitoring on the day of visit were included. Informed consent was obtained prior to blood sampling. PWE characteristics and biochemistry results were retrieved from clinical records and hospital information system. Each PWE was interviewed for the time of his/her last AED dose taken. Drug responses were categorized in accordance to the recent International League Against Epilepsy (ILAE) recommendations [19].
Sampling
Venous whole blood samples were collected in EDTA tubes. Two drops of blood from the withdrawn blood, ∼30 µL each, were spotted onto 903 cards (903 Neonate Blood Collection Cards, Whatman GmbH, Dassel, Germany) and dried at room temperature, 25°C for at least 3 hours. The rest of the whole blood was sent to hospital laboratory for plasma AED quantitations as per routine protocols. To maintain direct comparability with plasma levels, DBS samples were stored at −80°C until the day of analysis. The 3 AEDs were proven to be stable at −20°C and 25°C for at least 10 days at concentrations ranging from 0.5 mg/L to 100 mg/L (Table S1).
Plasma AEDs Quantification
The routine plasma AEDs quantifications were done in the hospital laboratory using particle enhanced turbidimetric inhibition immunoassays (Beckman Coulter Inc. Unicel DxC800, USA). The imprecisions in CV% (mean level, SD) for low, medium and high concentrations based on 21 data points over a period of typically 10 days are as following: i) Carbamazepine [range 2.0–20.0 mg/L] between run = 9.2% (4.2 mg/L, 0.39), 7.6% (10.79 mg/L, 0.82), 5.9% (15.24 mg/L, 0.93) and within run = 3.9% (3.92 mg/L, 0.15), 2.7% (10.41 mg/L, 0.28, 2.8% (15.24 mg/L, 0.43) ii) Phenytoin [2.5–40 mg/L] between run = 8.0% (5.18 mg/L, 0.42), 5.8% (15.03 mg/L, 0.83), 4.5% (30.40 mg/L, 1.36) and within run = 2.1% (5.00 mg/L, 0.11), 1.5% (13.76 mg/L, 0.20), 2.9% (28.19 mg/L, 0.80) iii) Valproic acid [10.0–150.0 mg/L] between run = 7.8% (33.26 mg/L, 2.59), 7.5% (75.90 mg/L, 5.68), 7.6% (125.70 mg/L, 9.55) and within run = 2.5% (33.03 mg/L, 0.82), 1.0% (67.99 mg/L, 0.70), 3.6% (112.83 mg/L, 4.09).
DBS Samples Processing
Quantitation was based on one 6-mm diameter DBS punch from the centre of the spot, containing approximately 15 µL of blood. AEDs extraction was performed using 500 µL of analytical grade (99%) acetonitrile (Prime Products Pte. Ltd., Singapore) and 1 molar sodium hydroxide (JT Baker, Phillipsburg, NJ, USA) at a ratio of 24∶1, v/v with 1 µg/mL 5-(p-methylphenyl)-5-phenylhydantoin (5MP) (Sigma Aldrich, St Louis, MO) as internal standard. The extraction procedure involved 1 min of vortexing and 5 min of sonication. Then, the mixture was centrifuged for 15 min at 6000 g. 400 µL of supernatant was transferred into 15 mL Kimble glass tube (Gerresheimer Co. Glass, Germany) for evaporation under nitrogen gas for 15 mins at 40°C. After addition of 100 µL of toluene to the dried sample, second drying phase under similar condition was carried out. Subsequently, derivatization was attained using 50 µL of N-methyl-N-trimethylsilyltrifluoroacetamide with 1% trimethylchlorosilane (Thermo Scientific Pte. Ltd., Waltham, Massachusetts, USA) incubated at an optimum 70°C for 50 min. Derivatised samples were cooled to room temperature and diluted with 50 µL of heptane before vortexing for 1 min. Finally, 80 µL of mixture was transferred into a 200 µL conical base inert glass insert placed in a 2 mL amber glass vial (Agilent Technologies, Santa Clara, California, USA).
Gas Chromatography Mass Spectrometry settings
The analytical assay was developed and validated with a GC-MS system that comprised of GC 2010 Shimadzu GC coupled to a GCMS-QP2010 Plus quadrupole MS (Shimadzu Corporation, Nishinokyo-Kuwabara-cho, Nakagyo-ku, Kyoto, Japan). GCMSsolution (version 2.0), was utilized for data acquisition and peak area computation. DB5 ms (30 m×0.25 mm×0.25 µm) supplied by Agilent Technologies J&W, Inc. was used as the capillary column. Injector temperature was set at 250°C, while ion source at 220°C. Injection volume of 1 µL was subjected to split ratio of 1∶5 and column flow was set at 1.9 mL/min. Column temperature began at 90°C with a 0.2-min isothermal hold. Temperature was then ramped at 4 different rates: i) 10°C/min to 120°C, held for 0.5 min ii) 65°C/min to 285°C, held for 0.5 min iii) 10°C/min to 291°C, held for 0.2 min and iv) 60°C/min to 300°C for a final isothermal hold of 5 min. Selective ion monitoring (SIM) mode was used for detection of the target analytes at their respective retention times and are tabulated in Table 1.
Table 1. Tabulation of selective ion monitoring (SIM) attributes and the ions monitored for the respective analytes.
Analytes | Retention Time | Quantifying Ion | Qualifying Ions |
Valproic Acid | 3.453 min | 201 | 129, 145 |
Phenytoin | 7.068 min | 281 | 165, 176, 253 |
Carbamazepine | 7.166 min | 193 | 194, 293 |
5-methylphenylhydantoin | 7.245 min | 267 | 290, 395 |
Bioanalysis
Calibration and quality control standards were prepared in blood and spotted onto the 903 cards at 30 µL each. One 6-mm diameter disc was punched out from each DBS and used for analysis. The assay was validated over a range of 0.5–120 µg/mL for all three AEDs. Accuracy ranged from 100–110% and imprecision was <10%. The calculated limit of detection was 0.05 µg/mL for VPA and approximately 0.07 µg/mL for both PHT and CBZ. The recoveries of analytes were relatively high (75%–97%) and consistent (SD≤8.2%). Although the inconsistency increased to 11% at the lower limit of quantitation for CBZ, it was still within the FDA acceptable lower limit of quantification (<20%) (Table S2).
Statistical Analysis
DBS concentrations (Cdbs) and plasma concentrations (Cplasma) determined by the respective methods were directly compared. Theoretical Cplasma was calculated using a formula which accounts for the individual hematocrit values and red blood cell-to-plasma partition (RBC/plasma) ratio [20], [21].
where Hct is the individual hematocrit value and K is the RBC/plasma ratio of the AEDs. To ease clinical applicability, K was fixed at literature values of 0.29 [22] and 0.43 for PHT [20] and 0.04 [23] and 0.20 [24] for VPA. As for CBZ, its theoretical plasma concentration approaches that of Cdbs, rendering the effect of Hct on computation of theoretical Cplasma to be negligible. Moreover, the K for CBZ had been reported to be approximately equal to 1 [25].
Statistical analyses were done using SPSS 21 and MedCalc Version 12.6.1.0. Simple Deming regression was utilized to compare the 2 methods. The differences between methods were assessed using paired sample t-test. Bland-Altman plots were subsequently compiled using the theoretical Cplasma and observed Cplasma. Outliers were confirmed using standardized score and removal was considered if the score exceeded 2.5.
Results
Patients
A total of 181 PWE were recruited but only 165 PWE who provided DBS were included in the final analyses. Fourteen PWE were excluded due to undetectable Cplasma (<2 µg/mL), and 2 PWE were excluded as outliers. Characteristics of PWE within each AED group are tabulated in Table 2. Some PWE contributed 2 AED concentrations, resulting in a total DBSs of more than 165. No significant elevation in biochemistry results was noted. The median hematocrit of the venous samples was 41.3 (range 29.8–51). The average daily doses of CBZ, PHT and VPA used in this population were 870.5±413.22 mg, 284.1±71.33 mg and 934.0±317.89 mg, respectively.
Table 2. Characteristics of the people with epilepsy (PWE) grouped according to the type of antiepileptic drug.
Characteristics | Valproic Acid (n = 92) | Phenytoin (n = 49) | Carbamazepine (n = 108) |
Number of Eligible DBS | 85 | 43 | 101 |
Number of Excluded DBS | 7 | 6 | 7 |
Number of Subjects | 84 | 41 | 100 |
Male | 48 (57.1%) | 22 (53.7%) | 48 (48%) |
Age, Median (Range) | 44.3 (19–78) | 50.6 (18–72) | 42.9 (20–78) |
Ethnic, No. Subjects (%) | |||
Chinese | 74 (88.1%) | 37 (90.2%) | 89 (89%) |
Malay | 5 (6.0%) | 3 (7.3%) | 5 (5%) |
Indian | 3 (3.6%) | nil | 6 (6%) |
Others | 2 (2.3%) | 1 (2.4%) | nil |
Concurrent medications, No. Subjects (%) | |||
None | 7 (8.3%) | 22 (53.7%) | 22 (22%) |
Valproic Acid | - | 10 (24.4%) | 46 (46%) |
Phenytoin | 10 (11.9%) | - | nil |
Carbamazapine | 46 (54.8%) | nil | - |
Other AEDs | 21 (25.0%) | 9 (21.9%) | 32 (32%) |
Blood Chemistry, Median (range) | |||
Hematocrit (%) | 41.6 (30.7–51) | 42.7 (33.3–49.2) | 41.3 (29.8–49.7) |
Hemoglobin (g/dL) | 13.9 (9.8–16.8) | 14.0 (10.5–16.4) | 13.6 (9.2–16.8) |
Liver Function Test | Median (range) | ||
Albumin (g/L) | 40 (31–46) | 41 (31–47) | 41 (31–46) |
ALT (U/L) | 20 (8–109) | 24 (12–79) | 19 (9–43) |
AST (U/L) | 22 (12–59) | 22 (16–78) | 21 (12–59) |
GGT (U/L) | 53 (9–333) | 84 (27–417) | 50 (21–213) |
Drug Monitoring (µg/mL), Mean (standard deviation) | |||
Mean plasma levels | 57.1 (22.35)* | 9.7 (4.67)* | 8.4 (2.32) |
Mean DBS levels | 29.2 (14.67)* | 6.9 (3.92)* | 8.3 (2.56) |
Mean predicted plasma levels | 57.1 (20.31) | 9.7 (4.60) | 8.4 (2.27) |
Average dose (mg), Mean (standard deviation) | |||
870.5 (413.22) | 934.0 (317.89) | 284.1 (71.33) | |
ILAE Classification of Drug Response | |||
Drug Responsive | 28 (33.3%) | 21 (51.2%) | 31 (31%) |
Drug Resistant | 31 (36.9%) | 9 (22.0%) | 38 (38%) |
Undefined | 25 (29.8%) | 11 (26.8%) | 31 (31%) |
Total recruited PWE were 183. Only 169 were included in the analysis. The remaining 14 subjects were excluded due to missing plasma levels from hospital laboratory system. (Note: Some recruited PWE contributed to the levels of two AEDs).
DBS and plasma concentrations
Figure 1 illustrates the relationships between the Cdbs and Cplasma for the three AEDs. Good correlations were demonstrated for all three AEDs, with correlation coefficients of r = 0.8381, 0.9305 and 0.8531 for CBZ, PHT and VPA, respectively. Cdbs and Cplasma of CBZ were almost identical with the slope converging with line of unity. In contrast, Cdbs of PHT and VPA were found consistently lower than their corresponding Cplasma, averaging at 2.8±1.89 µg/mL (29.7±13.59%) and 28.3±12.73 µg/mL (49.5±22.3%), respectively (p<0.005). Moreover, 95% CI for the slopes of PHT and VPA diverge anti-clockwise from the line of unity and did not cross the value 1. This signifies that there was at least a proportional increase in correlation between Cplasma and Cdbs of the two AEDs.
When regressed against the theoretical Cplasma, definite improvements in fit between data points from the turbimetric assay and DBS assay were observed. The lines of regression for respective AEDs rotated closer to the line of unity and data points clustered in greater proximity along the identity line, albeit marginal decrease in correlation coefficients for PHT and VPA ( Figure 2 ). The theoretical Cplasma of PHT was found to be comparable to its observed Cplasma ( Figure 2 , top). However, the regression line drawn using the theoretical Cplasma of PHT obtained using K of 0.29 produced a better fit with 95% CI of the slope of 1 ( Figure 2 , top left) than the one obtained using K of 0.43 ( Figure 2 , top right). As for VPA, the observed Cplasma was still higher than both theoretical Cplasma calculated using K of 0.20 ( Figure 2 , bottom left) and 0.042 ( Figure 2 , bottom right), but at the constant values of their intercepts.
Figure 3 shows the Bland-Altman plots of all three AEDs using their respective theoretical Cplasma. The concentration used for CBZ was Cdbs while for PHT and VPA, the theoretical Cplasma was used in comparison with their observed Cplasma. The mean difference between the concentrations from the proposed new method and conventional plasma immunoassay was −0.1 µg/mL for CBZ. For the theoretical PHT Cplasma calculated using K = 0.43, the mean difference was −0.7 µg/mL while with K = 0.29, the mean difference was zero. As for VPA, the differences were −13.7 and −8.1 µg/mL with K of 0.20 and 0.042, respectively. Since most of these differences fell within the acceptable limit of ±1.96 SD for all three AEDs, it is safe to assume that the theoretical Cplasma derived from Cdbs corresponded well with the observed Cplasma. Based on the preceding discussion, the theoretical Cplasma of VPA estimated from K = 0.04 and PHT estimated from K = 0.29 yielded better fit with convergence to the line of unity and were therefore, recommended for clinical use.
Discussion
In line with a presumed K of 1.06 from literatures, the RBC dilutional effect on Cdbs of CBZ was found to be negligible [21], [25]. Since CBZ partitions between RBC and plasma to a similar extent, the concentrations measured in whole blood were approximately the same as the plasma concentrations. This enables a direct comparison between Cdbs and Cplasma of CBZ in this study, giving a conversion factor of about 0.9.
Contrasting to CBZ, the Cdbs of VPA was found to be constantly lower than its Cplasma. Similar finding were previously observed by Vermeij and Edelbroek in their study. They found a conversion factor of 1.46 from Cdbs to Cplasma, which implied that the Cplasma of VPA was 46% higher than its Cdbs [13]. The lower concentrations measured from DBS could be attributed to a combination of factors. Firstly, RBC accounted for 99% of cellular space of blood and its presence may serve to dilute the VPA concentrations compared to those measured in plasma alone [26]. Secondly, for drugs with whole blood-to-plasma concentration ratio of less than (1–Hct), such as VPA, they should not partition into RBC significantly [21]. The inclusion of RBC in DBS will produce a dilution effect upon total drug concentration. It is projected that only the unbound drugs can partition into RBCs [27], [28] and that this partition is consistent at varying concentrations [29], [30]. VPA has been shown to partition into the RBC from the plasma at ratios ranging from 0.04 to 0.20 [23], [24], [29]. Since most of our patients had plasma VPA concentrations within the therapeutic ranges, and normal albumin levels, the K was presumably to be constant [29]. Hence, the relatively small amount of VPA in RBC was less likely to contribute substantial value towards the overall Cdbs. Thirdly, due to its lipophilic nature, VPA could dissolve and detach from RBC during centrifugation of whole blood to obtain the plasma and resulted in the relatively higher concentrations observed in the plasma [31], [32]. Alternatively, despite the extraction yield of >80% (RSD<6.0%) between 1 to 250 mg/L (Table S2), the binding of VPA to 903 cards may have some effect affecting the lower Cdbs.
After incorporating the hematocrit and K values, definitive improvement was achieved for the computation of the theoretical Cplasma of VPA. Yet, the theoretical Cplasma derived from Cdbs remained consistently lower than Cplasma. The most probable explanations include the domination of RBC dilutional effect and VPA binding to 903 cards. In clinical practice, however, the potential consequence of the difference in calculated Cplasma from Cdbs may not be obvious. An example of a worst case prediction would be, for an actual Cplasma of 60 µg/mL, the predicted Cplasma could either be 48 or 72 µg/mL. Regardless of the variation in the predicted Cplasma, physicians are likely to increase the dose if the PWE has uncontrolled seizure, hence arriving at the similar clinical decisions. Therefore, the clinical decisions premised upon Cdbs will be no different from the clinical decisions made using Cplasma.
On the other hand, PHT is readily partitions into and dissociates from the RBC, with a K reported to be approximately 0.29 [22] and 0.43 in healthy patients [20]. Its whole blood-to-plasma concentration was approximately 1.33 in both studies, which was comparable to 1.14 and 1.23, before and after corrected for Hct and K, found in this study. PHT binds to hemoglobin in RBCs [33] and was shown to be released disproportionally in vivo [22]. For drugs with high partition ratio into RBC such as thioridazine and derivatives, the RBC concentrations tend to have better association with treatment outcomes as compared to their plasma concentrations [34]. Therefore, obtaining an overall concentration from whole blood might provide insights into uncontrolled seizure despite having optimal plasma PHT concentration.
Effect of hematocrit and compound specific red blood cell-to-plasma ratios
In this study, we demonstrated that compound-specific RBC-to-plasma binding and individual hematocrit level could explain the difference in concentrations detected from DBS and plasma. It seems that as RBC-to-plasma partitioning approaches 1, e.g. 1.06 for CBZ, the closer the Cdbs is to its Cplasma and hematocrit level will have no dilution effect. Conversely, as RBC-to-plasma partitioning approaches 0, the dilution effect of hematocrit level becomes prominent and higher hematocrit levels lower Cdbs. DBS does seem to equate the whole blood characteristics which were demonstrated in previous studies [21], [30]. For lipophilic drugs such as AEDs, RBC is an important and useful transporter with high capacity but low affinity to the drugs. RBC readily releases the drug it carries and equilibrates with surrounding tissues in capillary system. Although Cplasma is an optimal representation of tissue concentration, RBC concentration of drug may function similarly. The constant ratios of RBC/plasma water over a wide range of AEDs concentrations proved that RBC is not a saturable system [22], [29]. Therefore, RBC concentration of drug may be negligible at low concentration, but will definitely gain importance as the concentration increases.
At clinically relevant blood and liver biochemistry variations, correcting the Cdbs to hematocrit and K improved the theoretical prediction of Cplasma for PHT and VPA. Nevertheless, this study catered for the investigation of PWE with AED binding to the red blood cells and albumin in the normal ranges. It is reasonable to assume that the effects of AED binding to blood cells and albumin should not fluctuate significantly. For the former effect, the Ks were fixed at 2 values for PHT and VPA. As evidenced by the improved graphical fit, correspondence with the actual Cplasma was improved with the inclusion of K. Similary, a constant K value has also been used to enhance the clinical applicability and harmonize the analytical process of PHT and VPA in whole blood samples [22], [29],.
The PWE recruited in this study represented the typical population of PWE who required the routine therapeutic drug monitoring. However, there were no inclusion of children, critically ill patients nor subjects who have just started the AED/s treatment. Hence, the applicability of this DBS quantitation method for dose titration for these cohorts of subjects remains unknown. These subjects could have a more fluctuating Hct and/or drug levels. Their theoretical Cplasma would be more challenging to be determined from the corresponding Cdbs levels. The applicability of Cdbs as a surrogate to Cplasma and even seizure control in these subjects need to be established in the future studies.
It is noteworthy that on this study, the DBS was obtained from venous source. Theoretically, there could be some differences between capillary and venous concentrations but the differences for a majority of xenobiotics were proven not to be obvious, especially after the distribution phase [35]–[37]. Therefore, at steady state drug concentrations, the difference between capillary and venous concentrations should be negligible. Blood concentrations from either source could be used interchangeably for estimating the AEDs Cplasma [37]. In conclusion, the theoretical Cplasma can be estimated through the equations below for the respective AEDs:
where Hct represents the individual hematocrit value, Cplasma CBZ, Cplasma PHT and Cplasma VPA represents the plasma concentrations of CBZ, PHT and VPA, respectively, while Cdbs CBZ, Cdbs PHT and Cdbs VPA represents the dried blood spot concentrations of CBZ, PHT and VPA, respectively For the theoretical Cplasma of PHT and VPA, the conversion factors, K = 0.29 and K = 0.04, were respectively recommended due to its proximity to the line of unity.
Conclusion
In view of the good agreement between the theoretical Cplasma estimated from the Cdbs levels and the observed Cplasma for PHT and VPA, and also between the Cdbs and the observed Cplasma for CBZ, DBS is deemed suitable as an alternative matrix to the conventional plasma samples for TDM of AEDs in the adult population of PWE. Further studies that investigate the pharmacokinetic parameters such as clearance and apparent volume of distribution using the Cdbs levels and then correlate these concentrations to the treatment outcomes are warranted.
Supporting Information
Acknowledgments
Previous presentation: Poster presentation of partial results at 10th European Congress on Epileptology, London, 30 September – 4 October 2012.
Data Availability
The authors confirm that all data underlying the findings are fully available without restriction. All relevant data are within the paper and its supporting information files.
Funding Statement
The authors have no funding or support to report.
References
- 1. Patsalos PN, Berry DJ, Bourgeois BF, Cloyd JC, Glauser TA, et al. (2008) Antiepileptic drugs–best practice guidelines for therapeutic drug monitoring: a position paper by the subcommission on therapeutic drug monitoring, ILAE Commission on Therapeutic Strategies. Epilepsia 49: 1239–1276. [DOI] [PubMed] [Google Scholar]
- 2. Froscher W, Rosche J (2013) [Combination therapy for epilepsy]. Fortschr Neurol Psychiatr 81: 9–20. [DOI] [PubMed] [Google Scholar]
- 3. Tan WW, Kong ST, Chan DW, Ho PC (2012) A retrospective study on the usage of antiepileptic drugs in Asian children from 2000 to 2009 in the largest pediatric hospital in Singapore. Pharmacoepidemiol Drug Saf 21: 1074–1080. [DOI] [PubMed] [Google Scholar]
- 4. Lim SH, See SJ, Wong PS, Lim SH (2012) Cost of antiepileptic drug monotherapies and combination therapies at a tertiary referral hospital in Singapore. Epilepsia 53: 194. [Google Scholar]
- 5. Tai SS, Yeh CY, Phinney KW (2011) Development and validation of a reference measurement procedure for certification of phenytoin, phenobarbital, lamotrigine, and topiramate in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry. Anal Bioanal Chem 401: 1915–1922. [DOI] [PubMed] [Google Scholar]
- 6. Serralheiro A, Alves G, Fortuna A, Rocha M, Falcao A (2013) First HPLC-UV method for rapid and simultaneous quantification of phenobarbital, primidone, phenytoin, carbamazepine, carbamazepine-10,11-epoxide, 10,11-trans-dihydroxy-10,11-dihydrocarbamazepine, lamotrigine, oxcarbazepine and licarbazepine in human plasma. J Chromatogr B Analyt Technol Biomed Life Sci 925: 1–9. [DOI] [PubMed] [Google Scholar]
- 7. Shibata M, Hashi S, Nakanishi H, Masuda S, Katsura T, et al. (2012) Detection of 22 antiepileptic drugs by ultra-performance liquid chromatography coupled with tandem mass spectrometry applicable to routine therapeutic drug monitoring. Biomed Chromatogr 26: 1519–1528. [DOI] [PubMed] [Google Scholar]
- 8. Piredda S, Monaco F (1981) Ethosuximide in tears, saliva, and cerebrospinal fluid. Ther Drug Monit 3: 321–323. [DOI] [PubMed] [Google Scholar]
- 9. Patsalos PN, Berry DJ (2013) Therapeutic drug monitoring of antiepileptic drugs by use of saliva. Ther Drug Monit 35: 4–29. [DOI] [PubMed] [Google Scholar]
- 10. Monaco F, Mutani R, Mastropaolo C, Tondi M (1979) Tears as the best practical indicator of the unbound fraction of an anticonvulsant drug. Epilepsia 20: 705–710. [DOI] [PubMed] [Google Scholar]
- 11. Edelbroek PM, van der Heijden J, Stolk LM (2009) Dried blood spot methods in therapeutic drug monitoring: methods, assays, and pitfalls. Ther Drug Monit 31: 327–336. [DOI] [PubMed] [Google Scholar]
- 12. Li W, Tse FL (2010) Dried blood spot sampling in combination with LC-MS/MS for quantitative analysis of small molecules. Biomed Chromatogr 24: 49–65. [DOI] [PubMed] [Google Scholar]
- 13.Vermeij T, Edelbroek P (2011 Personal Communication) Determination of Anticonvulsant Blood Levels Using the Blood Spot Method.
- 14. Deglon J, Versace F, Lauer E, Widmer C, Mangin P, et al. (2012) Rapid LC-MS/MS quantification of the major benzodiazepines and their metabolites on dried blood spots using a simple and cost-effective sample pretreatment. Bioanalysis 4: 1337–1350. [DOI] [PubMed] [Google Scholar]
- 15.Shah NM, Hawwa AF, Millership JS, Collier PS, Ho P, et al.. (2013) Adherence to antiepileptic medicines in children-A multiple-methods assessment involving dried blood spot sampling. Epilepsia. [DOI] [PubMed]
- 16. Rani S, Malik AK (2012) A novel microextraction by packed sorbent-gas chromatography procedure for the simultaneous analysis of antiepileptic drugs in human plasma and urine. J Sep Sci 35: 2970–2977. [DOI] [PubMed] [Google Scholar]
- 17. Linnet K (1999) Necessary sample size for method comparison studies based on regression analysis. Clin Chem 45: 882–894. [PubMed] [Google Scholar]
- 18.Krouwer JS (2010) Method comparison and bias estimation using patient samples: approved guidelines. Wayne, Pa: Clinical and Laboratory Standards Institute. xx, 56 p. [Google Scholar]
- 19. Kwan P, Arzimanoglou A, Berg AT, Brodie MJ, Allen Hauser W, et al. (2010) Definition of drug resistant epilepsy: consensus proposal by the ad hoc Task Force of the ILAE Commission on Therapeutic Strategies. Epilepsia 51: 1069–1077. [DOI] [PubMed] [Google Scholar]
- 20. Ehrnebo M, Odar-Cederlof I (1975) Binding of amobarbital, pentobarbital and diphenylhydantoin to blood cells and plasma proteins in healthy volunteers and uraemic patients. Eur J Clin Pharmacol 8: 445–453. [DOI] [PubMed] [Google Scholar]
- 21. Hinderling PH (1997) Red blood cells: a neglected compartment in pharmacokinetics and pharmacodynamics. Pharmacol Rev 49: 279–295. [PubMed] [Google Scholar]
- 22. Driessen O, Treuren L, Meijer JW, Hermans J (1989) Distribution of drugs over whole blood: II. The transport function of whole blood for phenytoin. Ther Drug Monit 11: 390–400. [PubMed] [Google Scholar]
- 23. Han S, Kim Y, Jeon J-Y, Hwang M, Im Y-J, et al. (2012) Rapid and Sensitive Analysis of Valproic Acid in Human Red Blood Cell by LC-MS/MS. Bulletin of the Korean Chemical Society 33: 1681–1685. [Google Scholar]
- 24. Shirkey RJ, Jellett LB, Kappatos DC, Maling TJ, Macdonald A (1985) Distribution of sodium valproate in normal whole blood and in blood from patients with renal or hepatic disease. Eur J Clin Pharmacol 28: 447–452. [DOI] [PubMed] [Google Scholar]
- 25. Bonneton J, Genton P, Mesdjian E (1992) Distribution of carbamazepine and its epoxide in blood compartments in adolescent and adult epileptic patients. Biopharm Drug Dispos 13: 411–416. [DOI] [PubMed] [Google Scholar]
- 26.Diem K, Lentner C (1975) Documenta Geigy Scientific Tables. Geigy Pharmaceuticals (Ciba-Geigy Ltd.). 617–618 p. [Google Scholar]
- 27. Kurata D, Wilkinson GR (1974) Erythrocyte uptake and plasma binding of diphenylhydantoin. Clin Pharmacol Ther 16: 355–362. [DOI] [PubMed] [Google Scholar]
- 28. Hinderling PH (1984) Kinetics of partitioning and binding of digoxin and its analogues in the subcompartments of blood. J Pharm Sci 73: 1042–1053. [DOI] [PubMed] [Google Scholar]
- 29. Driessen O, Treuren L, Meijer JW (1989) Distribution of drugs over whole blood: I. The transport function of whole blood for valproate. Ther Drug Monit 11: 384–389. [PubMed] [Google Scholar]
- 30. Highley MS, De Bruijn EA (1996) Erythrocytes and the transport of drugs and endogenous compounds. Pharm Res 13: 186–195. [DOI] [PubMed] [Google Scholar]
- 31. Schanker LS, Johnson JM, Jeffrey JJ (1964) Rapid Passage of Organic Anions into Human Red Cells. Am J Physiol 207: 503–508. [DOI] [PubMed] [Google Scholar]
- 32. Holder LB, Hayes SL (1965) Diffusion of sulfonamides in aqueous buffers and into red cells. Mol Pharmacol 1: 266–279. [PubMed] [Google Scholar]
- 33.Hilzenbecher C (1972) Die bindung von pharmaka an human haemoglobin. [Dissertation]. Munich: Ludwig Maximilian University.
- 34. Svensson C, Nyberg G, Axelsson R, Martensson E (1986) Concentrations of thioridazine and thioridazine metabolites in erythrocytes. Psychopharmacology (Berl) 89: 291–292. [DOI] [PubMed] [Google Scholar]
- 35. Mohammed BS, Cameron GA, Cameron L, Hawksworth GH, Helms PJ, et al. (2010) Can finger-prick sampling replace venous sampling to determine the pharmacokinetic profile of oral paracetamol? Br J Clin Pharmacol 70: 52–56. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36. Graves NM, Holmes GB, Leppik IE, Galligher TK, Parker DR (1987) Quantitative determination of phenytoin and phenobarbital in capillary blood by Ames Seralyzer. Epilepsia 28: 713–716. [DOI] [PubMed] [Google Scholar]
- 37. Haidukewych D, Splane ML, Vasos B (1986) Enzyme immunochromatographic assay of phenytoin in capillary and venous blood compared with fluorescence polarization immunoassay of plasma from epileptic patients. Clin Chem 32: 204. [PubMed] [Google Scholar]