Elasticity of microscale volumes of viscoelastic soft matter by cavitation rheometry

Leonid Pavlovsky 1, Mahesh Ganesan 1, John G Younger 2, Michael J Solomon 1
PMCID: PMC4187255  PMID: 25316925

Abstract

Measurement of the elastic modulus of soft, viscoelastic liquids with cavitation rheometry is demonstrated for specimens as small as 1 μl by application of elasticity theory and experiments on semi-dilute polymer solutions. Cavitation rheometry is the extraction of the elastic modulus of a material, E, by measuring the pressure necessary to create a cavity within it [J. A. Zimberlin, N. Sanabria-DeLong, G. N. Tew, and A. J. Crosby, Soft Matter 3, 763–767 (2007)]. This paper extends cavitation rheometry in three ways. First, we show that viscoelastic samples can be approximated with the neo-Hookean model provided that the time scale of the cavity formation is measured. Second, we extend the cavitation rheometry method to accommodate cases in which the sample size is no longer large relative to the cavity dimension. Finally, we implement cavitation rheometry to show that the theory accurately measures the elastic modulus of viscoelastic samples with volumes ranging from 4 ml to as low as 1 μl.


The linear elastic modulus of a soft material is a mechanical property measurable by techniques such as mechanical rheometry, microrheology, and atomic force microscopy (AFM).1,2 Needs for both in vivo characterization of linear elasticity (such as in tissue viability) as well as rapid measurement (such as in quality control applications) have driven recent methods development.3–5 Mechanical rheometry typically requires approximately milliliter sample volumes and, if sample loading and testing durations are considered, requires as much as 5 min to test one specimen at one deformation frequency. Passive microrheology is a widely used technique to study the mechanical properties of small volumes (between ∼3 and 50 μl) of soft matter. One method of microrheology—which uses the multiple scattering technique of diffusing wave spectroscopy—requires as much as an hour of measurement time. This method can probe elastic moduli up to ∼2000 Pa.1,6,7 Microrheology measurements can also be impacted by the stability of the dispersed probes and the heterogeneity of the material studied.8,9 AFM can also be used to characterize the elastic modulus of very small volumes (<1 μl) of material; however, this technique requires long durations for measurements and sample preparation time.3,10 The duration of these techniques makes them challenging for high throughput applications, while their lack of portability complicates their use as in vivo diagnostics.

The cavitation rheometry technique of Zimberlin et al. characterizes the linear elastic modulus of soft matter with Young's modulus in the range of 0.12 kPa < E < 40 kPa.11,12 It is an inexpensive, fast, and portable method that estimates the elastic modulus by measurement of the critical pressure (Pc) required for internal cavitation. Cavitation is induced by air pumped through a needle inserted into the sample. The critical pressure predicts the elastic modulus, E, through the theory of cavitation in an incompressible hyperelastic material.11 A hyperelastic material is described by a rate independent constitutive model that relates the stress to a strain energy density function.13 Using a neo-Hookean strain energy function, the inflation pressure (P), cavity expansion ratio (λ), and the elastic modulus (E) are related by14

PE=54λ1λ46. (1)

The cavity expansion ratio is the ratio of the radius of the bubble (Rc) formed to the inner diameter of the needle (Ri), λ = Rc/Ri.11 The critical pressure, Pc, is the maximum inflation pressure, achieved as λ approaches infinity. If the surface tension (γ) of the material is accounted for, the critical pressure is11,15

Pc=5E6+2γRi. (2)

A linear fit of Pc versus 2/Ri yields the elastic modulus.

Two limitations of Eqs. (1) and (2) restrict the scope of this method. The first is that because the analysis assumes a neo-Hookean strain energy function, cavitation rheometry has only been used to characterize materials that are elastic solids.11,12,16–19 To extend this method to viscoelastic materials, the assumption of neo-Hookean mechanics must be examined relative to their rheological behavior. The second limitation is that Eqs. (1) and (2) are valid only in the “thick-shell” case of a sample volume whose dimension is large relative to the radius of the expanding cavity.14 To extend to smaller volumes, the cavitation rheology should be generalized to materials of finite volume. In this paper, we examine these two limitations by theoretical analysis, numerical simulation, and experimental validation. We find that the assumptions that underlie both limitations can be relaxed, allowing cavitation rheometry to be applied to a greater set of materials and a broader range of conditions.

We use semi-dilute solutions of high molar mass poly(ethylene oxide) (PEO, Polysciences, Inc., 1 × 106 g/mol) at 3.0%, 4.0%, 6.0%, and 8.0% (w/w) in water as model materials. In the linear regime, the frequency dependent shear elastic (G′(ω)) and viscous (G″(ω)) moduli of these test fluids are plotted in Fig. S1(a) (AR-G2 rheometer, TA Instruments, strain amplitude =0.3). Because these solutions are incompressible, Poisson's ratio is approximately 0.5 and the elastic and shear moduli are related as E′ = 3G′.20

The mechanical rheometry (Fig. S1) differs from the behavior of the neo-Hookean constitutive equation in two critical ways: First, a neo-Hookean material is purely elastic, while the polymer solutions display a finite viscous modulus, G″. Second, in hyperelastic models, the stress-strain relationship is independent of deformation path, strain rate and deformation history.19 Therefore, the neo-Hookean model describes a frequency-independent elastic modulus, while the polymer solution rheology exhibits frequency-dependent elasticity. We hypothesize that neither of these differences is critical to the application of cavitation rheometry. In the first case, we show that the viscous contribution to cavitation does not affect the data analysis of Eqs. (1) and (2). In the second case, we show, via imaging, that cavitation occurs at high frequency, at which G′ ∼ G″ or greater. In this limit, the estimate of G′ through cavitation rheometry agrees with mechanical rheometry.

The second limitation, the cavitation length scale, must be addressed to extend the technique to small, microliter volumes. The analysis for Eqs. (1) and (2) assumes that cavitation occurs in a region that is small relative to the overall volume of the material. Because the cavitation region scales on the needle radius, the sample volume must be significantly larger than ∼0.2 μl, the minimum volume of material necessary when commercially available needles are used. We hypothesize that, as the sample volume decreases into the microliter range, the thick-wall assumption must be relaxed and Eqs. (1) and (2) must be modified. To verify this second hypothesis, we formulate the elastic analysis for arbitrary volume and validate it by numerical simulation and small volume experiments.

The cavitation pressure of the four test fluids was measured with air as the cavitating agent, delivered at 0.4 ml/min via syringe pump (Fisher Scientific). To differentiate the viscoelastic response from that of a purely viscous fluid, experiments were also performed on glycerol. Cavitation was induced with five needle radii from 0.084 mm to 0.419 mm (Hamilton). The specimen volume was greater than 1 ml, a limit in which Eq. (2) applies. The time for cavitation was ∼10 s. Once initiated, cavity formation was rapid, typically <80 ms. The cavitation pressure is the maximum pressure observed.

Fig. 1(a) yields the shear elastic modulus from the intercept (i.e., it is 2/5 of the intercept) and γ from the slope of the fit. The cavitation of glycerol (gray) results in G′ = 0, within error. This result demonstrates an inelastic fluid can be identified as such by the technique. The error for glycerol provides a lower bound on the G′ resolution limit of cavitation rheometry. Specifically, the ∼50 Pa error in the intercept for glycerol indicates that a G′ of this magnitude or lower cannot be resolved. These values and standard errors of the mean are in Table I.

FIG. 1.

FIG. 1.

(a) Critical pressure of PEO solutions and glycerol, as a function of needle size; 3% (blue), 4% (red), 6% (black), 8% (green), and glycerol (grey). Five needle sizes were used (Ri of: 0.084 mm, 0.13 mm, 0.207 mm, 0.302 mm, and 0.419 mm), with three replicates each. The vertical error bars are standard error of the mean and the horizontal error bars are the manufacturer's variability in needle size. Inset: An individual cavitation experiment with 4% PEO and Ri = 0.419 mm, with Pc denoted as the maximum pressure. (b) Frame-by-frame images of cavitation event 4% PEO with Ri = 0.084 mm, captured at 120 fps.

TABLE I.

The shear elastic modulus and surface tension from cavitation curves of Figure 1(a) compared to the modulus from mechanical rheometry at a strain rate estimated from high-speed imaging. The total strain to cavitation and correction factor is also reported. The rheometry values for the 3% PEO sample were not evaluated due to limitations of the camera frame rate.

Test material Rheometry G′ (Pa) Cavitation G′ (Pa) Correction factor, k Total strain, ε Characteristic strain rate, ε˙ (s−1) Surface tension, (N/m)
3% PEO 91 ± 33 0.066 ± 0.006
4% PEO 140 205 ± 31 0.70 ± 0.11 1.80 270 0.071 ± 0.006
6% PEO 290 255 ± 20 1.1 ± 0.09 0.65 130 0.077 ± 0.004
8% PEO 590 305 ± 47 1.9 ± 0.30 0.21 74 0.088 ± 0.008
Glycerol −8 ± 48 0.069 ± 0.009

We compare the moduli to those determined from mechanical rheometry. We performed high-speed imaging of the cavity formation (Fig. 1(b)). From these images, we estimate a characteristic strain rate for cavitation at which mechanical and cavitation rheometry are compared. Images were acquired with a CCD camera at 120 frames per second (Pulnix Progressive Scan TM-6710) attached to a 20× stereoscope (Zeiss Stemi 2000-C). From the imaging, seen frame-by-frame for a 4% PEO solution in Fig. 1(b), we measured the bubble radius for each frame of cavity growth using image processing software (ImageJ). The local strain, εL, and the strain rate, ε˙, were determined at each frame as εL=(RjRj1)/Rj1 and ε˙=εL/tc, where tc is the time between frames j and j-1. The point of maximum strain rate was designated the critical condition for cavitation. The total strain, ε, was determined from the beginning of the experiment to the point of cavitation as ε=(Rj,criticalRi)/Ri. The cavitation rate varied from 74 s−1 (8% PEO) to 270 s−1 (4% PEO) for the cavitation pressures and surface tensions listed in Table I. By means of the Cox-Merz rule, we compare G′ at the cavitation rate to G′(ω) at the equivalent frequency from the mechanical rheology.21

The shear elastic moduli at the aforementioned frequencies are in a region at which G′ ∼ G″ and the elasticity of the system is significant. This correlation validates our first hypothesis and therefore, we directly compare the cavitation and mechanical rheometry at these deformation rates.

We establish a correction factor, k = G′Rheo/G′Cav to connect cavitation and mechanical rheometry. We find that the average correction factor (kavg = 1.23 ± 0.17) results in a cavitation rheometry deviation from the mechanical rheometry modulus that is not more than a factor of two. Although cavitation and mechanical rheometry agree to within a factor of two and both sets of moduli increase with increasing PEO, the dependence of each displays a different dependence of PEO concentration. This result is likely tied to the sensitivity of the comparison to the strain rate extracted from imaging; additional experimental and theoretical effort to improve this comparison is warranted. Nevertheless, the cavitation and mechanical rheometry results differ, on average, by less than a factor of two. Although not exact, this accuracy would be acceptable for many applications. For example, the difference in G′ between healthy tissue and a cancerous tumor is approximately an order of magnitude or greater.4

Table I also indicates that the liquid-air γ of the solutions increases modestly with PEO concentration. The γ of PEO solutions should be bounded 0.043 N/m and 0.072 N/m, the values for PEO and pure water, respectively.22–24 A value closer to water is expected because the polymers in solution have yet to diffuse to the freshly created interface.25,26 There is also the additional effect of finite viscosity, as discussed in the supplementary material (Fig. S3).31 Although this effect vanishes in the limit used to characterize the elastic modulus, it may affect γ characterization, and thereby be a determinant of the values and errors discussed.

We now address the second, volumetric, limitation of cavitation rheometry. The “thick-shell” assumption in Eqs. (1) and (2) takes the deformation due to cavitation to be local and contained within an infinitesimal volume surrounding the needle.27 The outer boundary of the specimen is sufficiently far from the needle and therefore unperturbed by cavitation deformation. However, with decreasing sample volume, the outer boundary approaches the radius of the expanding cavity, which creates a deformation field extending to the outer boundary (cf. supplementary material).31

To study these mechanics, we performed finite element simulations (COMSOL Multiphysics) of cavitation in finite volumes of a neo-Hookean material with internal loading and unconstrained radial expansion of the outer boundary,28 details of which can be found in the supplementary material.31 The volume of material was varied through the thickness of the elastic shell, H. The pressure curves found from simulation (Fig. 2 Inset) are plotted as P/E as a function Rc/Ri, where Rc is the cavity radius. The response is dependent on the amount of material initially present (i.e., (Ri + H)/Ri, where Ri + H is the radius of the specimen). At small material volumes ((Ri + H)/Ri ≤ 5), after reaching its critical value, the pressure decreases with increasing cavity expansion. This effect physically would be manifested as an unbounded expansion at this critical pressure.13 For (Ri + H)/Ri > 5, the critical pressure increases and occurs at increasingly larger values of Rc/Ri. At large volumes, such as (Ri + H)/Ri = 20, the pressure reaches an asymptotic limit of ∼5E/6, consistent with Eq. (2). The critical pressure is significantly lower for finite volumes (i.e., Pc ∼ 0.5E and ∼0.2E at (Ri + H)/Ri equal to 5 and 1.5, respectively). This difference indicates that applying Eq. (2) in this regime is not valid.

FIG. 2.

FIG. 2.

The dependence of normalized critical pressure (Pc/E) on the volume ratio of material as from finite element analysis (black circles) and theory (blue line). These results were fit with Eq. (4) to determine parameters a and b. Inset: Simulation and theory of normalized pressure versus normalized cavity radius (Rc/Ri) during inflation. The curves are for [Ri + H]/Ri of 1.5 (blue), 2.0 (red), 5.0 (green), and 20.0 (black).

We analyzed the mechanics of cavity deformation in a neo-Hookean material. The material is defined as a hollow sphere of internal radius, Ri, and an external radius, Ri + H, which is free to expand. Assuming incompressibility, the application of a pressure at the inner wall generates equibiaxial extension.27 Upon solving the equilibrium momentum balance subject to the boundary conditions of internal loading and an unbounded surface, we find that the applied pressure, P, and deformation, λ, are related as

P=E6λb4+2E3λbE3(12λ4+2λ). (3)

Here, λ is the spatially varying stretch ratio of the cavity and λb is the stretch ratio of the material at any point within the elastic shell. Additional details are found in the supplementary material.31 By numerically solving Eq. (3) and comparing to simulations, we find that the theory curve overlays exactly with the simulation results (Fig. 2 Inset). Furthermore, we numerically generate pressure-stretch curves to determine Pc at many dimensionless sample thicknesses. From these calculated values, we obtain the modified cavitation equation by fitting the results (Fig. 2) to

Pc=5E6[6a5(Ri+HRi)b+1], (4)

where a and b are fitting parameters, equal to −0.8558 and −0.6547, respectively. Under the limit of infinite material volume ((Ri + H)/Ri → ∞), Eq. (4) approaches Eq. (2) monotonically, thus validating our fit. This equation is valid for all H > 0, as Ri + H > Ri.

Equation (4) predicts that the cavitation pressure in finite volumes is a function of the elastic modulus and the geometric parameter (Ri + H)/Ri. To test this equation in the finite volume limit, 4% PEO droplets of varying volume were dispensed on a glass slide. To cause the PEO droplet to bead, the glass was coated with a hydrophobic layer (Rain-X). The droplet dimensions were measured with a stereoscope equipped with a CCD camera (PCO Pixelfly QE). The overall volume of our PEO droplets were approximately 1 μl.

Cavitation was induced in the small volume drops by pressurization of the syringe. The measured cavitation pressures, after subtracting the surface tension term as determined by large volume cavitation (2γ/Ri), are plotted for a range of drop dimensions in Fig. 3(b). The trend between the small volume (circles) and large volume experiments (squares) is consistent with both the simulation and theory reported earlier. The small volume experiments were fit with Eq. (4), which yielded an elastic modulus of 840 Pa. The large volume experiments, from Table I, found E = 615 Pa, a discrepency of 35%. Moreover, the large volume data fell within the 95% confidence interval of our small volume fitting, further indicating the applicability of Eq. (4).

FIG. 3.

FIG. 3.

(a) Image of ∼1 μl droplet of 4% PEO solution on a hydrophobic glass slide for small volume cavitation. The needle and characteristic dimension, Ri + H, are shown. (b) Pc, with the surface tension contribution subtracted, plotted for a range of drop dimensions. Small (circles) and large (squares) volume cavitation experiments are plotted and fit (solid line) with Eq. (4). The 95% confidence interval (dotted lines) are shown.

In conclusion, cavitation rheometry has been extended to estimate the elastic modulus of viscoelastic fluids and small volumes. Areas for future attention include viscoelastic modeling of the cavitation experiment; this step would allow correspondence between this technique and other methods for elongation deformation, and their accompanying instabilities, to be better assessed.29,30 These extensions improve the scope for the method's application to areas such as in situ and high throughput rheology.

Acknowledgments

This work was supported by the NSF CDI Program (Grant No. PHYS-0941227), the NIGMS (Grant No. GM-069438), and a University of Michigan Rackham Merit Fellowship (to L.P.). We thank Professor M. A. Burns for use of the high-speed camera.

References

  • 1.Cicuta P. and Donald A. M., Soft Matter 3, 1449 (2007). 10.1039/b706004c [DOI] [PubMed] [Google Scholar]
  • 2.Gavara N. and Chadwick R., Nat. Nanotechnol. 7, 733 (2012). 10.1038/nnano.2012.163 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Balooch M., Wu-Magidi I. C., Balazs A., Lundkvist A. S., Marshall S. J., Marshall G. W., Siekhaus W. J., and Kinney J. H., J. Biomed. Mater. Res. 40, 539 (1998). 10.1002/(SICI)1097-4636(19980615)40:4<539::AID-JBM4>3.0.CO;2-G [DOI] [PubMed] [Google Scholar]
  • 4.Yeh W.-C., Li P.-C., Jeng Y.-M., Hsu H.-C., Kuo P.-L., Li M.-L., Yang P.-M., and Lee P. H., Ultrasound Med. Biol. 28, 467 (2002). 10.1016/S0301-5629(02)00489-1 [DOI] [PubMed] [Google Scholar]
  • 5.Pavlovsky L., Younger J. G., and Solomon M. J., Soft Matter 9, 122 (2013). 10.1039/c2sm27005f [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Mason T. G. and Weitz D. A., Phys. Rev. Lett. 74, 1250 (1995). 10.1103/PhysRevLett.74.1250 [DOI] [PubMed] [Google Scholar]
  • 7.Lu Q. and Solomon M. J., Phys. Rev. E 66, 061504 (2002). 10.1103/PhysRevE.66.061504 [DOI] [PubMed] [Google Scholar]
  • 8.Squires T. M. and Mason T. G., Annu. Rev. Fluid Mech. 42, 413 (2010). 10.1146/annurev-fluid-121108-145608 [DOI] [Google Scholar]
  • 9.Savin T. and Doyle P. S., Biophys. J. 88, 623 (2005). 10.1529/biophysj.104.042457 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Jalili N. and Laxminarayana K., Mechatronics 14, 907 (2004). 10.1016/j.mechatronics.2004.04.005 [DOI] [Google Scholar]
  • 11.Zimberlin J. A., Sanabria-DeLong N., Tew G. N., and Crosby A. J., Soft Matter 3, 763–767 (2007). 10.1039/b617050a [DOI] [PubMed] [Google Scholar]
  • 12.Zimberlin J. A., McManus J. J., and Crosby A. J., Soft Matter 6, 3632 (2010). 10.1039/b925407b [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Ogden R. W., Non-linear Elastic Deformations ( Halsted Press, New York, 1984), p. 532 [Google Scholar]
  • 14.Gent A. N., Int. J. Non Linear Mech. 40, 165 (2005). 10.1016/j.ijnonlinmec.2004.05.006 [DOI] [Google Scholar]
  • 15.Gent A. N. and Tompkins D. A., J. Appl. Phys. 40, 2520 (1969). 10.1063/1.1658026 [DOI] [Google Scholar]
  • 16.Zimberlin J. A. and Crosby A. J., J. Polym. Sci., Part B: Polym. Phys. 48, 1423 (2010). 10.1002/polb.21968 [DOI] [Google Scholar]
  • 17.Delbos A., Cui J., Fakhouri S., and Crosby A. J., Soft Matter 8, 8204 (2012). 10.1039/c2sm25458a [DOI] [Google Scholar]
  • 18.Kundu S. and Crosby A. J., Soft Matter 5, 3963 (2009). 10.1039/b909237d [DOI] [Google Scholar]
  • 19.Treloar L. R. G., The Physics of Rubber Elasticity, 3rd ed. ( Oxford University Press, New York, 2005). [Google Scholar]
  • 20.Ferry J. D., Viscoelastic Properties of Polymers, 3rd ed. ( John Wiley & Sons, New York, 1980), p. 641 [Google Scholar]
  • 21.Macosko C. W., Rheology: Priniciples, Measurements, and Applications ( Wiley-VCH, Inc., New York, 1994), p. 550 [Google Scholar]
  • 22.Roe R.-J., J. Phys. Chem. 72, 2013 (1968). 10.1021/j100852a025 [DOI] [Google Scholar]
  • 23.Rastogi A. K. and Pierre L. E. St., J. Colloid Interface Sci. 35, 16 (1971). 10.1016/0021-9797(71)90179-2 [DOI] [Google Scholar]
  • 24.Dean J. A., Lange's Handbook of Chemistry, 15th ed. ( McGraw-Hill Professional, 1998), p. 1424 [Google Scholar]
  • 25.Alvarez N. J., Walker L. M., and Anna S. L., Langmuir 26, 13310 (2010). 10.1021/la101870m [DOI] [PubMed] [Google Scholar]
  • 26.Eastoe J. and Dalton J. S., Adv. Colloid Interface Sci. 85, 103 (2000). 10.1016/S0001-8686(99)00017-2 [DOI] [PubMed] [Google Scholar]
  • 27.Green A. E. and Zerna W., Theoretical Elasticity, 2nd ed. ( Dover Publications, Inc., Mineola, 2012). [Google Scholar]
  • 28.Holzapfel G. A., Nonlinear Solid Mechanics: A Continuum Approach for Engineering ( John Wiley & Sons, New York, 2000), p. 470 [Google Scholar]
  • 29.McKinley G. H. and Hassager O., J. Rheol. 43, 1195 (1999). 10.1122/1.551034 [DOI] [Google Scholar]
  • 30.Malkin A. Y. and Petrie C. J. S., J. Rheol. 41, 1 (1997). 10.1122/1.550881 [DOI] [Google Scholar]
  • 31.See supplementary material at http://dx.doi.org/10.1063/1.4896108E-APPLAB-105-045438 for details about the mechanical rheometry of PEO, the effects of viscosity on cavitation rheometry, the finite element simulations, and the derivations of the volume-dependent cavitation equation.

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Citations

  1. See supplementary material at http://dx.doi.org/10.1063/1.4896108E-APPLAB-105-045438 for details about the mechanical rheometry of PEO, the effects of viscosity on cavitation rheometry, the finite element simulations, and the derivations of the volume-dependent cavitation equation.

Articles from Applied Physics Letters are provided here courtesy of American Institute of Physics

RESOURCES