Skip to main content
BMC Cancer logoLink to BMC Cancer
. 2014 Sep 30;14:730. doi: 10.1186/1471-2407-14-730

Computed tomography Hounsfield units can predict breast cancer metastasis to axillary lymph nodes

Masakazu Urata 1, Yuko Kijima 1,, Munetsugu Hirata 1, Yoshiaki Shinden 1, Hideo Arima 1, Akihiro Nakajo 1, Chihaya Koriyama 2, Takaaki Arigami 1, Yoshikazu Uenosono 1, Hiroshi Okumura 1, Kosei Maemura 1, Sumiya Ishigami 1, Heiji Yoshinaka 1, Shoji Natsugoe 1
PMCID: PMC4193134  PMID: 25266250

Abstract

Background

Axillary lymph node (ALN) status is an important prognostic factor for breast cancer. We retrospectively used contrast-enhanced computed tomography (CE-CT) to evaluate the presence of ALN, metastasis based on size, shape, and contrasting effects.

Methods

Of 131 consecutive patients who underwent CE-CT followed by surgery for breast cancer between 2005 and 2012 in our institution, 49 were histologically diagnosed with lymph node metastasis. Maximum Hounsfield units (HU) and mean HU were measured in non-contrasting CT (NC-CT) and CE-CT of ALNs.

Results

Of 12 examined measurements, we found significant differences between negative and metastatic ALNs in mean and maximum NC-CT HU, and mean and maximum CE-CT HU (P < 0.05). We used a receiver operating curve, to determine cut-off values of four items in which significant differences were observed. The highest accuracy rate was noted for the cut-off value of 54 as maximum NC-CT HU for which sensitivity, specificity, and accuracy rate were 79.6%, 80.5% and 80.2%, respectively.

Conclusions

CT HU of a patient with breast cancer are absolute values that offer objective disease management data that are not influenced by the screener’s ability.

Keywords: Breast cancer, Computed tomography, Hounsfield unit, Lymph node metastasis, Diagnosis, Axillary lymph node

Background

Breast cancer is the most common newly diagnosed cancer type and the fifth most common cause of cancer-related death among women in Japan [1]. Status of axillary lymph nodes (ALNs) is the most important predictor of survival [2].

Manual palpation is a well-known method that is used to non-invasively detect ALN metastasis [3]; however, it has low specificity and sensitivity and cannot accurately predict the ALN status [4]. Contrast-enhanced computed tomography (CE-CT) has been used to evaluate ALN metastasis based on size, shape, and contrasting effects [510]. Use of whole-body 18 F-fluorodeoxy glucose- positron emission tomography (FDG-PET)/CT for breast cancer staging and treatment monitoring has also recently increased due to its ability to detect previously unknown metastases [1116]. However, its diagnostic accuracy for ALN staging has not yet been established [16, 17].

Hounsfield units (HU) are a measure of X-ray attenuation in CT images. This retrospective study evaluated ALN metastasis against HU to determine optimal cut-off values.

Methods

Patients

Between January 2005 and May 2012, 283 consecutive patients with invasive ductal carcinoma (IDC) underwent breast and axillary surgery in our hospital without any neoadjuvant systemic therapy such as chemotherapy or endocrine therapy. Of these patients, 131 underwent CE-CT prior to surgery in our hospital using the same system, and were enrolled in this study; the other 152 patients underwent CE-CT using a different system in another hospital. All subjects had undergone mammography, ultrasonography (US), core needle biopsies for their primary breast lesions, bone scintigraphy for preoperative staging. Magnetic resonance imaging, FDG-PET, and pathological or cytological examinations for ALNs, depending on the case. Sentinel lymph node (SLN) biopsies were performed on 51 patients with diagnoses of clinical T1N0M0 breast cancer according to the TNM classification [18]. The dye and radioisotope method used to detect SLNs was reported previously [19]. Axillary lymphadenectomy was performed on 27 and 18 patients who were diagnosed with T1-4N1M0 or T2-4N0M0, respectively. Of 51 patients who underwent SLN biopsies, 9 received additional axillary lymphadenectomy due to findings of metastasis by the intraoperative histological examination.

Patient characteristics and the pathological and surgical findings were collected from our database records and individual patient electronic medical records, and was approved by the Institutional Review Board of the Kagoshima University Medical and Dental Hospital. We received informed consent from each study participant and approval for our protocol from the Ethics Committee of Kagoshima University.

Table  1 shows clinicopathological features of the 131 patients enrolled in this study. Their average age was 58.3 years (range: 21–95 years). One patient was diagnosed with T1mic cancer, 73 with T1, 32 with T2, 7 with T3, and 18 with T4 lesions. Total and partial mastectomies were performed on 74 and 57 patients, respectively. SLN biopsy was performed on 42 patients, SLN biopsy followed by axillary lymphadenectomy on 9 patients, and axillary lymphadenectomy on 80 patients. Of the 131 patients, 49 had lymph node metastasis. All metastases were evaluated as macrometastasis (Table  1).

Table 1.

Clinical characteristics of the 131 patients

Variable
Age in years, average (range) 58.3 (21–95)
Menopause
   Pre 41 (31.3%)
   Post 90 (68.7%)
Pathological T stage
   T1mic 1 (0.8%)
   T1a 11 (8.4%)
   T1b 21 (16.0%)
   T1c 41 (31.3%)
   T2 32 (24.5%)
   T3 7 (5.3%)
   T4 18 (13.7%)
Procedure
   Total mastectomy 74 (56.5%)
   Partial mastectomy 57 (43.5%)
Lymph node dissection
   SNB* without axillary lymphadenectomy 42 (32.1%)
   SNB* with axillary lymphadenectomy 9 (6.9%)
   Axillary lymphadenectomy 80 (61.0%)
Lymph node metastasis
   Positive 49 (37.4%)
   Negative 82 (62.6%)

*Sentinel lymph node biopsy.

Testing set

All 95 consecutive patients with IDC who underwent breast and axillary surgery in our hospital between June 2012 and July 2014 with no neoadjuvant therapy underwent CE-CT: 40 before surgery in our hospital using the same system, and the other 55 patients using a different system in another hospital. We enrolled the 40 former patients in this testing set.

CT scanning

Patients were examined in a supine position with their arms stretched above their heads at the end of inspiration using a CT scanner (Aquilion TM64, Toshiba Medical, Tokyo, Japan). Scanning parameters included 120 kVp, a 0.5-second tube rotation, 53° helical pitch, 206-mm table speed, 0.5 second gantry rotation time, and 3-mm thick reconstructed sections. Images were analyzed on SYNAPSE (Fuji Film, Inc., Tokyo, Japan).We observed 437 ALNs in 131 patients on CT. On some slides, in which both the pectoralis major and minor muscles were detected, we evaluated all lymph nodes without any information on pathological findings. The mean number of evaluated lymph nodes in each patient was 3.34 (range: 2–6). Maximum and mean HU were measured in non-contrasting CT (NC-CT) and CE-CT ALNs, contralateral ALNs, the aortic inside arch and the pectoralis major muscle. To measure lymph node HU with/without internal fat at normal lymph node hila, we traced outlines of lymph nodes by hand to highlight a range of interest (ROI) (Figure  1). To exclude artificial contamination, we excluded these outlines when we evaluated mean HU values, but included them to determine maximum HU values. On each lymph node, we also evaluated long- and short-axis diameters, and internal fat density, which indicated absence of central images for bilateral ALNs. The highest value of a patient’s several lymph nodes was used as the value for that patient. Mean HU, maximum HU, and primary tumor size were simultaneously determined in the same manner.

Figure 1.

Figure 1

Measurement of axillary lymph nodes in a patient with invasive ductal carcinoma in the left breast. A. ALN sizes were measured in the maximum sectioned surface of the CT image with 3-mm slices: (1) Longest transverse diameter of the oval lymph node; (2) Shortest transverse diameter of the oval lymph node; B. To measure mean HU, we selected a range of interest (ROI) such that the line did not protrude from the ALN edge. C. ROI surrounded the lymph node, and the maximum HU inside of the ROI was measured. We took extra care not to include bone or blood vessels near the ROI.

Pathological evaluation

All dissected ALNs were cut into single sections and stained with hematoxylin–eosin for analysis by a pathologist. Both micro- and macro-metastasis were considered positive.

Statistical analysis

Data were evaluated using SPSS Ver.20 software (IBM SPSS, Chicago, IL). Student’s t-test was used to assess differences between the groups. P < 0.05 was considered significant. We examined mean HU and maximum HU of the ALNs and primary tumor on both NC-CT and CE-CT. We examined differences between metastatic lymph nodes and non-metastatic lymph nodes using 18 measurements, as shown in Table  2. We then used the Youden index of receiver operating characteristic (ROC) curve to determine cut-off values for items in which a significant difference was observed in the t-test. The ROC curve was drawn using SPSS Ver.20 software (Figure  2, for an example).

Table 2.

Comparisons between negative and positive lymph nodes for 12 CT measurements

Lymph node metastasis
Factors (mean ± SD) Negative (n = 82) Positive (n = 49) P
Mean NC-CT HU of lymph node 7.83 ± 22.31 29.17 ± 16.37 < 0.05
Maximum NC-CT HU of lymph node 34.28 ± 23.58 60.06 ± 17.52 < 0.05
Mean CE-CT HU of lymph node 52.45 ± 27.29 78.09 ± 22.49 < 0.05
Maximum CE-CT HU of lymph node 86.95 ± 27.58 118.63 ± 23.14 < 0.05
Mean NC-CT HU of primary tumor 36.09 ± 18.88 37.28 ± 16.58 0.89
Maximum NC-CT HU of primary tumor 69.30 ± 30.65 78.17 ± 18.55 0.11
Mean CE-CT HU of primary tumor 91.92 ± 28.36 89.03 ± 31.45 0.39
Maximum CE-CT HU of primary tumor 135.81 ± 31.27 148.88 ± 25.32 0.88
Long-axis diameter of lymph node (mm) 6.05 ± 2.32 10.37 ± 4.75 < 0.05
Short-axis diameter of lymph node (mm) 4.42 ± 1.71 7.35 ± 3.39 < 0.05
Long-axis diameter of primary tumor (mm) 18.71 ± 10.14 40.54 ± 37.94 < 0.05
Short-axis diameter of primary tumor (mm) 12.99 ± 7.11 25.44 ± 33.37 < 0.05

CE-CT: contrast-enhanced computed tomography; HU: Hounsfield unit; NC-CT: non-contrasting computed tomography; SD: standard deviation.

Figure 2.

Figure 2

ROC curve of maximum HU of an unenhanced lymph node CT. The AUC of this case was 0.827. We made a ROC curve and found the cut-off value using the Youden index.

Results

HU value and lymph node metastasis

Mean NC-CT HU was 7.83 ± 22.31 for non-metastatic lymph nodes and 29.17 ± 16.37 for positive nodes. Similarly, maximum NC-CT HU, mean CE-CT HU, and maximum CE-CT HU were 34.28 ± 23.58, 60.06 ± 17.52 and 52.45 ± 27.29 for negative nodes; and 78.09 ± 22.49, 86.95 ± 27.58 and 118.63 ± 23.14 for positive nodes, respectively (Table  2). We also analyzed associations between pathological findings for metastasis and NC-CT and CE-CT HU values for ALNs, primary tumors, and long- and short-axis diameters (Table  2).

Of the 12 values, mean ALN NC-CT HU, maximum ALN NC-CT HU, mean ALN CE-CT HU, maximum ALN CE-CT HU, long- and short-axis ALN diameters, and long- and short-axis diameters of the primary tumor differed significantly for metastatic and negative ALNs; with maximum and mean HU significantly higher in positive nodes. However, in the primary tumors, none of the CT values correlated with ALN metastasis (Table  2).

Lymph node metastasis and diameters of the lymph node and primary tumor

Long- and short-axis diameters of metastatic lymph nodes were significantly larger than for negative nodes (P < 0.05, Table  2). Long- and short-axis diameters of primary tumors correlated with lymph node metastasis (P < 0.05 for both).

Diagnostic accuracy of HU values in detecting lymph node metastasis

For the four items with significantly higher HU values in metastatic lymph nodes—mean and maximum NC-CT HU values, and mean and maximum CE-CT HU values (Table  3)—we determined HU cut-off values, using the Youden index for ROC curves (Figure  2). The highest accuracy rate was found for maximum ALN NC-CT HU at a cut-off value of 54 (sensitivity: 79.6%; specificity: 80.5%; positive predictive value [PPV]: 70.9%; negative predictive value [NPV]: 86.8%; accuracy: 80.2%), followed by maximum ALN CE-CT HU at a cut-off value of 103 (sensitivity: 83.7%; specificity: 72.0%; PPV: 64.1%; NPV: 88.1%; accuracy: 76.3%), and mean ALN CE-CT HU at a cut-off value of 16 (sensitivity: 83.7%; specificity: 64.6%; PPV: 58.6%; NPV: 86.9%; accuracy: 71.8%). In the same way, we determined size cut-off values and listed sensitivity,specificity, PPV, NPV, and accuracy (Table  4).

Table 3.

HU measurements that differed significantly in metastatic and negative lymph nodes

Cutoff value Sensitivity Specificity PPV NPV Accuracy
(HU) (%) (%) (%) (%) (%)
Lymph node NC-CT
   Mean HU 16 83.7 64.6 58.6 86.9 71.8
   Maximum 54 79.6 80.5 70.9 86.8 80.2
Lymph node CE-CT
   Mean HU 60 85.7 58.5 55.3 87.3 68.7
   Maximum HU 103 83.7 72 64.1 88.1 76.3

CE-CT: contrast-enhanced computed tomography; HU: Hounsfield unit; NC-CT: non-contrasting computed tomography; NPV: negative predictive value; PPV: positive predictive value.

Table 4.

Size measurements that differed significantly in metastatic and negative lymph nodes

Cut-off value Sensitivity Specificity PPV NPV Accuracy
(mm) (%) (%) (%) (%) (%)
Lymph node
   Long-axis dia 7.42 75.5 74.4 63.8 83.6 74.8
   Short-axis dia 4.96 81.6 73.2 64.5 87 76.3
Primary tumor
   Long-axis dia 17.08 91.7 56.1 91.7 56.1 69.2
   Short-axis dia 16.27 57.1 81.7 65.1 76.1 72.5

Dia: diameter; NPV: negative predictive value; PPV: positive predictive value.

Evaluations of testing set

We used cut-off values for mean and maximum HU values of both NC-CT and CE-CT which were derived from 131 cases, to evaluate several lymph nodes in one patient, which we compared with pathologists’ findings, as shown in Table  5.

Table 5.

Testing set results for lymph node metastases; CT values compared with pathological findings

Mean NC-CT HU Pathological findings
Positive Negative Total
CT Positive 9 9 18
Negative 1 21 22
Total 10 30 40
Sensitivity 90.0%, Specificity 70.0%, PPV 50.0%, NPV 95.5%, Accuracy 75.0%
Maximum NC-CT HU Pathological findings
Positive Negative Total
CT Positive 10 7 17
Negative 0 23 23
Total 10 30 40
Sensitivity 100.0%, Specificity 76.7%, PPV 58.8%, NPV 100.0%, Accuracy 82.5%
Mean CE-CT HU Pathological findings
Positive Negative Total
CT Positive 7 13 20
Negative 3 17 20
Total 10 30 40
Sensitivity 70.0%, Specificity 56.7%, PPV 35.0%, NPV 85.0%, Accuracy 60.0%
Maximum CE-CT HU Pathological findings
Positive Negative Total
CT Positive 8 12 20
Negative 2 18 20
Total 10 30 40
Sensitivity 80.0%, Specificity 60.0%, PPV 40.0%, NPV 90.0%, Accuracy 65.0%

Diagnosis of metastasis through CT HU values.

CE-CT: contrast-enhanced computed tomography; HU: Hounsfield unit; NC-CT: non-contrasting computed tomography; NPV: negative predictive value; PPV: positive predictive value.

Discussion

The 10-year survival rate of patients with ALN metastasis depends on the number of involved nodes, and ranges from 30% for those with > 10 metastases to 90% for those with no metastasis [2]. The ALN status is not only important for estimating prognoses, but also for selecting individual treatment regimens [20]. The American College of Surgeons Oncology Group (ACOSOG) Z0011 trial showed that patients randomized to SLN dissection (SLND) alone or to SLND + ALN dissection (ALND), did not significantly differ in local or regional recurrence [21]. The ACOSOGZ0011 enrolled patients who were diagnosed as N0 before randomization, which supports the importance of preoperative ALN evaluation. Our present study could facilitate these evaluations.

The use of CT to assess ALN metastasis has been reported previously [510]. Relatively good results were reported for various criteria used to detect lymph node metastasis, such as short-axis ALN diameter, ratio of long- to short-axis ALN diameters, enhancement type, shape, or intra-nodal fat density [10, 2224]. Such methods are useful for detecting ALN metastasis, but may strongly depend on the personal ability of the screener.

Use of US in diagnosing ALN metastasis is also widely reported [25, 26]. Results of US for non-palpable axillary nodes based on nodal size showed that sensitivity varied between 48.8% (95% confidence interval: 39.6–58%) and 87.1% (76.1–94.3%) and specificity varied between 55.6% (44.7–66.3%) and 97.3% (86.1–99.9%); for lymph node morphology, sensitivity ranged from 26.4% (15.3–40.3%) to 75.9% (56.4–89.7%) and specificity ranged from 88.4% (82.1–93.1%) to 98.1% (90.1–99.9%) [25]. We previously reported that US screening of ALNs was useful both for diagnosing nodal metastasis, and for predicting prognoses. We showed that US sensitivity, specificity and accuracy rates were 69.5%, 85.8% and 79.7%, respectively [26]; however, its ease of use is somewhat offset by the influence of operator’s skill and possible subjectivity, whereas measuring CE-CT HU is a simple, easy method that does not depend on the physician’s skill.

In a voxel with average linear attenuation coefficient μx, the corresponding HU value is given by: HU = 1000 × (μx - μwater)/μwater - μair where μwater and μair are the linear attenuation coefficients of water and air; i.e., attenuation values expressed in HU are relative to the attenuation of radiation in water. Positive values represent tissues with attenuation values higher than that of water and negative values represent tissues with lower values. The number 1000, sometimes called the magnifying value, is incorporated into the above equation to expand the scale sufficiently to provide whole number attenuation values [27]. Mean HU can be influenced by ROI selection, whereas maximal HU does not vary with ROI placement. Although selecting an ROI cannot currently be automated or standardized, it is an easy manual skill that requires no special technique or software. However, neighboring structures (e.g., bone or blood vessels) should be carefully avoided in selecting a ROI, as maximum HU markedly changes when structures other than lymph nodes are included. Further study is needed to clarify the accuracy of segmentation for ROI delineation; such investigation might show how much of a learning curve exists to acquire the stable ability to determine the HU value by non-experts. We found sensitivity, specificity, PPV, NPV, and accuracy were 79.6%, 80.5%, 70.9%, 86.8%, and 80.2%, respectively, at a cut-off value of 54 for maximum NC-CT HU. As this result was superior to the findings of previous studies [11, 17, 25], clinical use of this cut-off value is feasible. Furthermore, accuracy rates were 76.3%, 71.8%, and 68.7% for maximum CE-CT HU, mean NC-CT HU, and mean CE-CT HU, respectively. Therefore, the maximum NC-CT HU cutoff appears adequate to estimate ALN metastasis. Our results showed that NC-CT effectively detected metastasis, and is clearly superior to CE-CT and PET-CT, even from the viewpoint of side effects and cost. In any case, we recommend that HU be measured to evaluate lymph node metastasis when deciding preoperative staging.

The testing set results under blind conditions validated the analysis. The cut-off value for maximum NC-CT HU showed sensitivity, specificity, PPV, NPV, and accuracy of 100.0%, 76.7%, 58.8%, 100.0%, and 82.5%, respectively, which is particularly useful in light of how easily obtainable this measurement is in routine preoperative examinations.

To our knowledge, this is the first study to show that metastatic and negative ALNs differ in their mean and maximum HU values. Metastases that contain tumor cells, vascularization, or immune reactions within lymph nodes may elevate HU values. Although we did not evaluate the relationship between metastatic area and HU values, further studies should be performed to clarify this issue.

This study had three limitations. First, maximum HU may measure artifacts [28], and no conclusive evidence currently shows that maximum HU can accurately assess ALN metastasis. We also examined HU in 3-mm CT slices in this study; however, HU values on image borders may be inaccurate for small structures such as lymph nodes due to the partial volume effect. Secondly, HU values depend on the CT machine, imaging conditions, and specifications of the image processing software, which differ in every institution, and may vary due to maintenance or an update. A cut-off value for HU in detecting ALN metastasis may only apply to selected patients who undergo NC-CT screening in the same institution. Thus, cut-off values should be regularly recalibrated before treating patients. Finally, comparing one-to-one correspondences between resected lymph nodes and CT ALN images in the present retrospective study was difficult. Confirming relationships between preoperative CT HU and intraoperative and postoperative histological evaluations should resolve these problems. We will be able to achieve higher accuracy by measuring several ALNs followed by the selection of one node with the highest HU value.

Conclusions

In conclusion, we have shown that measuring the maximum HU is a simple, easy, and useful technique for diagnosing ALN metastasis in breast cancer patients. However, as this was a retrospective study with relatively few patients, our results should be verified by a blinded prospective investigation by several researchers and a larger cohort.

Acknowledgements

We declare no financial relationship or other interests associated with this manuscript, which might be construed as constituting a conflict of interest. We’ve stated that the material has not been previously published or submitted elsewhere for publication.

Abbreviations

ALN

Axillary lymph node

CE-CT

Contrast-enhanced computed tomography

CT

Computed tomography

FDG

18 F-fluorodeoxy glucose

HU

Hounsfield unit

IDC

Invasive ductal carcinoma

NC-CT

Non-contrasting computed tomography

NPV

Negative predictive value

PET

Positron emission tomography

PPV

Positive predictive value

ROC

Receiver operating characteristic

ROI

Range of interest

SLN

Sentinel lymph node.

Footnotes

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

MU is first author of this work. MU, YK, MH and YS designed all the experiments. MU, HA, AN, YU and HO acquired data. CK and TA analyzed data. KM, SI, HY and SN were involved in manuscript revision. All authors were involved in drafting the manuscript and all read it and gave their final approval.

Contributor Information

Masakazu Urata, Email: uray@m3.kufm.kagoshima-u.ac.jp.

Yuko Kijima, Email: ykijima@m3.kufm.kagoshima-u.ac.jp.

Munetsugu Hirata, Email: springai@m3.kufm.kagoshima-u.ac.jp.

Yoshiaki Shinden, Email: shinden@m2.kufm.kagoshima-u.ac.jp.

Hideo Arima, Email: arima@m.kufm.kagoshima-u.ac.jp.

Akihiro Nakajo, Email: anakajo@m.kufm.kagoshima-u.ac.jp.

Chihaya Koriyama, Email: fiy@m.kufm.kagoshima-u.ac.jp.

Takaaki Arigami, Email: arigami@m.kufm.kagoshima-u.ac.jp.

Yoshikazu Uenosono, Email: uenosono@m3.kufm.kagoshima-u.ac.jp.

Hiroshi Okumura, Email: hokumura@m.kufm.kagoshima-u.ac.jp.

Kosei Maemura, Email: kmaemura@m3.kufm.kagoshima-u.ac.jp.

Sumiya Ishigami, Email: ishiga@m.kufm.kagoshima-u.ac.jp.

Heiji Yoshinaka, Email: heiji@m3.kufm.kagoshima-u.ac.jp.

Shoji Natsugoe, Email: natsugoe@m2.kufm.kagoshima-u.ac.jp.

References

  • 1.Matsuda A, Matsuda T, Shibata A, Katanoda K, Sobue T, Nishimoto H. Cancer Incidence and Incidence Rates in Japan in,2007. A Study of 21 Population-based Cancer Registries for the Monitoring of Cancer Incidence in Japan (MCIJ) Project. Jpn J Clin Oncol. 2007;2013(43):328–336. doi: 10.1093/jjco/hys233. [DOI] [PubMed] [Google Scholar]
  • 2.Miller WR, Ellis IO, Sainsbury JR, Dixon JM. ABC of breast diseases: Prognostic factors. BMJ. 1994;309:1573–1576. doi: 10.1136/bmj.309.6968.1573. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Fisher B, Wolmark N, Bauer M, Redmond C, Gebhardt M. The accuracy of clinical nodal staging and of limited axillary dissection as a determinant of histologic and nodal status in carcinoma of the breast. Surg Gynecol Obstet. 1981;152:765–772. [PubMed] [Google Scholar]
  • 4.Sacre RA. Clinical evaluation of axillary lymph nodes compared to surgical and pathological findings. Eur J Surg Oncol. 1986;12:169–173. [PubMed] [Google Scholar]
  • 5.Ogawa Y, Nishioka A, Nishigawa T, Kubota K, Kariya S, Yoshida S, Tanaka Y, Moriki T, Tochika N. Thin-section CT evaluation and pathologic correlation of therapeutic nodes of clinically node-positive breast cancer patients. Oncol Rep. 2003;10:985–989. [PubMed] [Google Scholar]
  • 6.Hata Y, Ogawa Y, Nishioka A, Inomata T, Yoshida S. Thin section computed tomography in the prone position for detection of axillary lymph node metastasis in breast cancer. Oncol Rep. 1998;5:1403–1406. doi: 10.3892/or.5.6.1403. [DOI] [PubMed] [Google Scholar]
  • 7.Yuen S, Sawai K, Ushijima Y, Okuyama C, Yamagami T, Yamada K, Nishimura T. Evaluation of axillary status in breast cancer. CT-based determination of sentinel lymph node size. Acta Radiol. 2002;43:579–586. doi: 10.1034/j.1600-0455.2002.430608.x. [DOI] [PubMed] [Google Scholar]
  • 8.Yuen S, Yamada K, Goto M, Sawai K, Nishimura T. CT-based evaluation of axillary sentinel lymph node status in breast cancer: value of added contrast-enhanced study. Acta Radiol. 2004;45:730–737. doi: 10.1080/02841850410001088. [DOI] [PubMed] [Google Scholar]
  • 9.Miyauchi M, Yamamoto N, Imanaka N, Matsumoto M. Computed tomography for preoperative evaluation of axillary nodal status in breast cancer. Breast Cancer. 1999;6:243–248. doi: 10.1007/BF02967178. [DOI] [PubMed] [Google Scholar]
  • 10.Shien T, Akashi-Tanaka S, Yoshida M, Hojo T, Iwamoto E, Miyakawa K, Kinoshita T. Evaluation of axillary status in patients with breast cancer using thin-section CT. Int J Clin Oncol. 2008;13:314–319. doi: 10.1007/s10147-007-0753-z. [DOI] [PubMed] [Google Scholar]
  • 11.Heusner TA, Kuemmel S, Hahn S, Koeninger A, Otterbach F, Hamami ME, Kimmig KR, Forsting M, Bockisch A, Antoch G, Stahl A. Diagnostic value of full-dose FDG PET/CT for axillary lymph node staging in breast cancer patients. Eur J Nucl Med Mol Imaging. 2009;36:1543–1550. doi: 10.1007/s00259-009-1145-6. [DOI] [PubMed] [Google Scholar]
  • 12.Zangheri B, Messa C, Picchio M, Gianolli L, Landoni C, Fazio F. PET/CT and breast cancer. Eur J Nucl Med Mol Imaging. 2004;31:135–142. doi: 10.1007/s00259-004-1536-7. [DOI] [PubMed] [Google Scholar]
  • 13.Lee JH, Rosen EL, Mankoff DA. The Role of Radiotracer Imaging in the Diagnosis and Management of Patients with Breast Cancer: Part 2—Response to Therapy, Other Indications, and Future Directions. J Nucl Med. 2009;50:738–748. doi: 10.2967/jnumed.108.061416. [DOI] [PubMed] [Google Scholar]
  • 14.Heusner TA, Kuemmel S, Umutlu L, Koeninger A, Freudenberg LS, Hauth EAM, Kimmig KR, Forsting M, Bockisch A, Antoch G. Breast cancer staging in a single session: whole-body PET/CT mammography. J Nucl Med. 2008;49:1215–1222. doi: 10.2967/jnumed.108.052050. [DOI] [PubMed] [Google Scholar]
  • 15.Wang Y, Yu J, Liu J, Tong Z, Sun X, Yang G. PET-CT in the diagnosis of both primary breast cancer and axillary lymph node metastasis: initial experience. Int J Radiat Oncol Biol Phys. 2003;57:362–3623. doi: 10.1016/S0360-3016(03)01267-7. [DOI] [Google Scholar]
  • 16.Yang WT, Le-Petross HT, Macapinlac H, Carkaci S, Gonzalez-Angulo AM, Dawood S, Resetkova E, Hortobagyi GN, Cristofanilli M. Inflammatory breast cancer: PET/ CT, MRI, mammography, and sonography findings. Breast Cancer Res Treat. 2008;109:417–426. doi: 10.1007/s10549-007-9671-z. [DOI] [PubMed] [Google Scholar]
  • 17.Ueda S, Tsuda H, Asakawa H, Omata J, Fukatsu K, Kondo N, Kondo T, Hama Y, Tamura K, Ishida J, Abe Y, Mochizuki H. Utility of 18 F-fluoro-deoxyglucose emission tomography/computed tomography fusion imaging (18 F-FDG PET/CT) in combination with ultrasonography for axillary staging in primary breast cancer. BMC Cancer. 2008;8:165. doi: 10.1186/1471-2407-8-165. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Sobin LH, Hermanek P, Hutter RP. TNM classification of malignant tumors. A comparison between the new (1987) and the old editions. Cancer. 1988;61:2310–2314. doi: 10.1002/1097-0142(19880601)61:11&#x0003c;2310::AID-CNCR2820611127&#x0003e;3.0.CO;2-X. [DOI] [PubMed] [Google Scholar]
  • 19.Kijima Y, Yohinaka H, Uenosono Y, Funasako Y, Ehi K, Yanagita S, Arima H, Kozono T, Arigami T, Natsugoe S, Aikou T. Intramammary sentinel lymph node in patients with breast cancer: Report of four cases. Surg Today. 2008;38:536–540. doi: 10.1007/s00595-007-3660-z. [DOI] [PubMed] [Google Scholar]
  • 20.Ranaboldo CJ, Mitchel A, Royle GT, Theaker GM, Taylor I. Axillary nodal status in women with screen-detected breast cancer. Eur J Surg Oncol. 1993;19:130–133. [PubMed] [Google Scholar]
  • 21.Giuliano AE, McCall L, Beitsch P, Whitworth PW, Blumencranz P, Leitch AM, Saha S, Hunt KK, Morrow M, Ballman K. Locoregional recurrence after sentinel lymph node dissection with or without axillary dissection in patients with sentinel lymph node metastases: the American College of Surgeons Oncology Group Z0011 randomized trial. Ann Surg. 2010;252(3):426–432. doi: 10.1097/SLA.0b013e3181f08f32. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Mizuno Y, Satake H, Sawaki A, Sawaki M, Hayashi H, Kobayashi H, Hibi Y, Shibata A, Kikumori T, Imai T. Preoperative Axillary Lymph Node Evaluation by MDCT Imaging. Japanese of Breast Cancer. 2006;21:367–371. [Google Scholar]
  • 23.Nasu Y, Shikishima H, Miyasaka Y, Nakakubo Y, Ichinokawa K, Kaneko T. A Study of the Assessment of Axillary Lymph Nodes Before Surgery for Breast Cancer Using Multidetector-Row Computed Tomography. Surg Today. 2010;40:1023–1026. doi: 10.1007/s00595-009-4185-4. [DOI] [PubMed] [Google Scholar]
  • 24.Uematsu T, Sano M, Homma K. In Vitro High-Resolution Helical CT of Small Axillary Lymph Nodes in Patients with Breast Cancer: Correlation of CT and Histology. Am J Roentgenol. 2001;176:1069–1074. doi: 10.2214/ajr.176.4.1761069. [DOI] [PubMed] [Google Scholar]
  • 25.Alvarez S, Anorbe E, Alcorta P, López F, Alonso I, Cortés J. Role of sonography in the diagnosis of axillary lymph node metastases in breast cancer: a systematic review. Am J Roentgenol. 2006;186:1342–1348. doi: 10.2214/AJR.05.0936. [DOI] [PubMed] [Google Scholar]
  • 26.Kijima Y, Yoshinaka H, Hirata M, Mizoguchi T, Ishigami S, Nakajo A, Arima H, Ueno S, Natsugoe S. Number of axillary lymph node metastases determined by preoperative ultrasound is related to prognosis in patients with breast cancers. Cancer. 2010;2:20–31. doi: 10.3390/cancers2010020. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Michel M. In: Computed body tomography. Lee JKT, Sagel SS, Stanley RJ, editors. New York: Raven; 1983. pp. 4–5. [Google Scholar]
  • 28.Mori I, Kazama M. Method for Suppressing Streak Artifacts in CT Resulting from Excessive Noise. Med Imaging Technol. 2003;21:272–276. [Google Scholar]

Pre-publication history

  1. The pre-publication history for this paper can be accessed here:http://www.biomedcentral.com/1471-2407/14/730/prepub

Articles from BMC Cancer are provided here courtesy of BMC

RESOURCES