Abstract
The continuing development of robotic surgery supports its use in laparoscopic gastrointestinal surgery. Our study retrospectively reviewed the surgical outcome and patient’s satisfaction of gastrointestinal laparoscopic robotic procedures. From January 2003 to September 2007, 94 patients (27 women, 67 men) with a mean age of 53 years (range 19–84 years) underwent laparoscopic surgery with a da Vinci robotic system. There were 40 colorectal cases (43%), 31 anti-reflux surgery cases (33%) and 14 obesity surgery cases (15%); the remaining cases consisted of gastric and gallbladder surgery, intra-abdominal tumour excisions, and hepatic cyst resections. The majority of the cases (88, 94%) were performed for benign disease. The mean operative time was 153 min (range 60–330 min). One patient needed a blood transfusion. The mean body mass index was 25 (range 16–47). No death occurred. Five cases (5.3%) were converted to conventional laparoscopic surgery (n = 3) or to laparotomy (n = 2). Morbidity consisted of one Nissen redo surgery to loosen a tight anti-reflux valve 6 days after robotic surgery, a robotic left ureter repair and pelvic haemorrhage following proctectomy requiring re-operation to control haemostasis and to remove pelvic haematoma. Mean follow-up time was 11 months (range 15 days to 34 months). One case of incisional trocar hernia needed re-operation. Overall patient’s satisfaction was high: few scars were cheloïd, while functional surgical outcome was rated high by most of the patients. Our preliminary experience was encouraging, with minimal morbidity and very high acceptance by patients.
Keywords: Colon, Colorectal cancer, Diverticular diseases, Gastric banding, Gastro-esophageal reflux diseases, Nissen fundoplication, Obesity surgery, Rectum, Robotic surgery
Introduction
In 1987, the first laparoscopic cholecystectomy was performed by P. Mouret [1]. Ten years later, Himpens et al. performed the first robotic cholecystectomy using a prototype system with remote control and a three-dimensional viewing through the use of specially developed glasses [2].
More sophisticated robotic systems were later developed which provided – or improved upon – a stable camera platform, three-dimensional imaging, excellent ergonomics, instruments with a wide-range degree of freedom and modulation of motion amplitude with tremor filtering. The current da Vinci robotic system (Intuitive Surgical, Sunnyvale, CA) is the most highly used system worldwide. The first da Vinci system was installed in Geneva in 2003, and to the best of our knowledge, our team has had the most experience among Swiss clinicians in gastrointestinal cases using this system.
The aim of the study reported here was to determine surgical feasibility, evaluate functional outcome and assess patients’ satisfaction using this system.
Material and methods
To date, 94 consecutive patients have been treated by our team. From January 2003 to December 2006, the three-arm da Vinci system was used (73 cases), and from January 2007 to September 2007, our team used the four-arm da Vinci system (21 cases). During the entire study period, 409 robotic procedures were performed at our institution, consisting of 300 urologic cases (73%), 94 gastrointestinal cases (23%) and 15 gynecologic cases (4%). Each patient’s data were prospectively collected using a robotic logbook; a clinical information sheet for each individual was filled up by the surgeon and anesthesiologist and later stored in our computerized database system. A retrospective analysis was then performed to retrieve data. The follow-up was done during a patient's visit to the attending physician and/or telephone interview. The patient's evaluation was obtaining using a visual analog score (1–10). Approval by our local Ethics Committee was obtained prior to carrying out this study.
Results
They were 27 men (29%) and 67 women (71%) in our patient cohort, with a mean age of 53 years (range 19–84 years). Overall, mean hospital stay was 7 days (range 2–24 days), and mean body mass index (BMI) was 25 (range 16–47). A blood transfusion was needed in one case (1%). Benign cases accounted for 88 patients (94%). Only six patients (6%) had malignant diseases: five colorectal adenocarcinomas and one intra-abdominal teratoma. The surgical procedures consisted of 40 colorectal cases (43%), 31 anti-reflux cases (33%), 14 morbid obesity cases (15%) and nine miscellaneous cases (10%).
Colorectal procedures consisted of sigmoidectomy (n = 20), sigmoidectomy and rectopexy (n = 8), right colectomy (n = 3), rectopexy (n = 3), low anterior resection (n = 2), caecectomy (n = 1), anterior resection (n = 1), abdomino-perineal resection (n = 1) and resection of recto-vaginal endometriosis nodule (n = 1). Diagnoses prior to the surgical procedure were: diverticular disease (n = 20, 50%), rectal prolapse (n = 11, 27.5%), adenocarcinoma (n = 6, 15%), benign multiple polyp or endoscopically non-resectable polyp (n = 2, 5%) and recto-vaginal endometriosis (n = 1, 2.5%). The mean age of patients undergoing colorectal procedures was 60 years (range 32–84 years). The mean hospital stay was 9 days (range 3–24), and the mean BMI was 22 (range 19–40). Mean operative time was 162 min (range 60–330 min). Two patients were re-operated (one for a left ureter injury in which a robotic suture was performed, another for pelvic bleeding by conventional laparoscopy). There were three conversions to laparoscopy (two cases for difficult dissection, one for a robotic technical problem) and two conversions to laparotomy (one robotic technical problem, and one difficult dissection). Finally, one patient developed a trocar incisional hernia.
The second most frequent procedure was Nissen fundoplication for gastro-esophageal reflux disease. The mean age of patients undergoing this procedure was 49 years (range 19–68 years). The mean hospital stay was 6 days (range 4–13 days), while the mean BMI was 27.3 (range 19–36). The mean operative time was 166 min (range 60–270 min). Associated cholecystectomy was performed in four cases. Two patients required a Nissen redo procedure, and there was one conversion to laparotomy during a Nissen redo because of an esophageal tear.
Gastric banding was the third most common surgical procedure in our series (14 cases). The mean age of patients undergoing this procedure was 41 years (range 20–58 years). The mean hospital stay was 4 days (range 3–7 days), and mean BMI was 41 (range 34–46). The mean operative time was 141 min (range 90–240 min). One patient had had a previous laparoscopic gastric banding. There was one conversion to laparotomy.
Among the miscellaneous procedures, there were four intra-abdominal tumor resections (three benign cysts and one teratoma), two cholecystectomies, two partial gastric resections and one case of hepatic cyst resection.
A patient's satisfaction was evaluated using a visual analog score system: the mean value of functional outcome of the surgical procedure was 8 (range 3–10), and of satisfaction with regard to the entire procedure was 7 (range 2–10). Five patients developed cheloid scars (5%). Mean follow-up time for all patients was 11 months (range 15 days to 34 months). Six patients were lost to follow-up (6%).
Discussion
Several studies have reported surgical results using the da Vinci robotic system in which this technique has been shown to be applicable and safe [3–9]. No morbidity related to the system has yet been observed. Overall, the reported mortality rate has ranged between 0 and 1.8%, while the rate of complication has been less than 10%; conversion to conventional laparoscopy and/or laparotomy was less than 5%. Almost all studies reported a longer operative time using the robotic system as compared to conventional laparoscopy. Increased overall costs due to longer operative time and the use of more expensive instruments was reported for cases of Nissen fundoplication and colectomy [10–15].
Our team has not experienced the death of a patient during the robotic procedure, and we have observed a morbidity of 3.1%. Conversion to laparoscopy/laparotomy was 5.3%. At the beginning of our learning experience, operative time was long, and although it has diminished with time and experience, it is still longer than conventional laparoscopy. To date, no proven patient-specific advantage of robotic surgery over laparoscopic techniques has been demonstrated. The robotic system allows the surgeon to perform more sophisticated procedures, whereas classical gastrointestinal procedures can be performed safely. The development of mini robots and augmented reality techniques will boost robotic surgery in the future [9, 16]. We have found that colon and rectum resections, anti-reflux surgery, and obesity surgery were safe and efficacious for the patients.
Several authors have reported good results with colorectal robotic surgery [17–25]. Our experience in terms of operative time, conversion rate, mortality, complications rate and length of stay are similar to those reported in the literature (Table 1). It is our impression that the use of the da Vinci system is from a technical point of view particularly useful for proctectomy with total mesorectum excision (TME) in cases of rectal cancer [25], as lymph node harvesting, nerve sparing and anatomical TME is enhanced by the three-dimensional vision of the pelvis. As reported by others, we prefer to do a hybrid procedure (conventional laparoscopic inferior mesenteric high vessel ligature and splenic flexure take down) and robotic proctectomy with TME [6]. This approach prevents a prolonged operative time and the unnecessary displacing of the robot. Right colectomy for cancer with primary vessels ligation can be performed robotically with great ease; at the end of the procedure, the anastomosis is performed outside the abdomen. Sigmoidectomy for benign disease can also be performed easily as no high vascular ligature is necessary and the splenic flexure is left in place. The operative time for a right colectomy is shorter than that for a left colectomy [24].
Table 1.
Author | Year | Number of cases | Mean operative time, minutes (range) | Conversion (%) | Mortality (%) | Complications (%) | Mean length of hospital stay, days (range) |
---|---|---|---|---|---|---|---|
Delaney et al. [18] | 2003 | 6 | 217 (170–270) | 16.6 | 0 | 0 | 3 (2–5) |
Giulanotti et al. [6] | 2003 | 16 | 202 (150–360) | 0 | 0 | 0 | NA |
Anvari et al. [19] | 2004 | 10 | 155 ± 13.6 | 0 | 0 | 10 | NA |
D’Annibale et al. [20] | 2004 | 53 | 240 ± 61 | 3.7 | 0 | 7.5 | 10 ± 4 |
Hanly and Talamini [28] | 2004 | 35 | 177 | 14.2 | NA | NA | NA |
Hubens et al. [29] | 2004 | 8 | 124 (87–144) | 0 | 0 | 37.5 | NA |
Woeste et al. [21] | 2005 | 6 | 236 ± 5.8 | 16.6 | 0 | 16.6 | NA |
Bodner et al. [7] | 2005 | 14 | 310 | 0 | 0 | 0 | NA |
Braumann et al. [22] | 2005 | 5 | 201 (80–300) | 40 | 0 | 0 | 13.6 (9–14) |
DeNoto et al. [23] | 2006 | 11 | 195 (145–345) | 9 | 0 | 0 | 3.4 (3–4) |
Rawlings et al. [24] | 2006 | 30 | RC 177 (103–306) LC 225 (147–283) |
6.6 | 0 | 20 | RC 5.2 (2–27) LC 6 (3–30) |
Pigazzi et al. [25] | 2006 | 6 | 280 (200–330) | 0 | 0 | 16.6 | 4.5 (3–11) |
Current series | 2007 | 40 | 162 (60–330) | 12.5 | 0 | 5 | 9 (3–24) |
NA, Not available
Given the limited space for dissection and the need to mobilize the great gastric curvature, robotic Nissen fundoplication and other anti-reflux techniques have been often performed [3–4, 6, 11–13, 26–32]. The surgical outcome of our series is in line with other reports as shown in Table 2. Randomized controlled trials have demonstrated that conventional Nissen fundoplication give similar results to the robotic approach, but it is less expensive and less time consuming [11–13, 32]. Cost analysis should be performed in each country as health systems are differ significantly.
Table 2.
Author | Year | Number of cases | Mean operative time, minutes (range) | Conversion (%) | Mortality (%) | Complications (%) | Mean length of stay, hours (range) |
---|---|---|---|---|---|---|---|
Cadière et al. [3] | 2001 | 36 | 82 (54–125) | 5.5 | 0 | 0 | 2 (1–4) |
Chitwood et al. [4] | 2001 | 14 | 107 ± 3.2 | 0 | 0 | 0 | NA |
Giulanotti et al. [6] | 2003 | 49 | 110 (40–300) | 2 | 0 | 5 | 4 |
Benincà et al. [23] | 2003 | 13 | 97.1 (77–126) | 0 | 0 | 7.6 | 3.2 (2–7) |
Hanly and Talamini [28] | 2004 | 57 | 192 | 22.8 | 0 | NA | NA |
Hubens et al. [29] | 2004 | 9 | 100 (83–139) | 0 | 0 | NA | NA |
Anvari et al. [30] | 2005 | 13 | 73 (45–90) | NA | 0 | NA | NA |
D’annibale et al. [20] | 2006 | 21 | 140 (60–240) | 0 | 0 | 9.5 | 7.6 (4–11) |
El Nakadi et al. [11] | 2006 | 9 | 137 ± 12 | 11.1 | 0 | 11.1 | 4.4 ± 0.2 |
Morino et al. [12] | 2006 | 25 | 131.3 (90–162) | 8 | 0 | 0 | 3 (2–6) |
Müller-Stich et al. [13] | 2007 | 20 | 88 (60–150) | 0 | 0 | 0 | 2.9 ± 0.8 |
Heemskerk et al. [15] | 2007 | 11 | 220 | 0 | 0 | 9 | 4 |
Current series | 2007 | 31 | 166 (60–270) | 3.3 | 0 | 3.3 | 6 (4–13) |
NA, Not available
It has recently been suggested that the use of the da Vinci robotic system is valuable for obesity surgery, specifically in cases of gastric banding [3, 7, 29, 33–35] and gastric bypass surgery [36, 37]. Our current experience in obesity surgery is associated with gastric banding devices. The surgical outcome is shown in Table 3. The totally robotic Roux-en-Y gastric bypass is feasible and safe, but this technique is still being evaluated and compared to conventional laparoscopy, although it seems promising in terms of surgical outcome and BMI reduction [36, 37].
Table 3.
Author | Year | Number of cases | Mean operative time, minutes (range) | Conversion (%) | Mortality (%) | Complications (%) | Mean length of stay, days (range) |
---|---|---|---|---|---|---|---|
Cadière et al. [3] | 2001 | 10 | 60 (55–90) | 0 | 0 | 0 | 2 (2–3) |
Mühleman et al. [33] | 2003 | 6 | 137 (11–175) | 0 | 0 | 0 | NA |
Jacobsen [34] | 2003 | 32 | 105 (60–150) | 0 | 0 | 3.1 | 1 (0.2–6) |
Nguyen [35] | 2004 | 2 | NA | NA | 0 | NA | NA |
Hubens et al. [29] | 2004 | 7 | NA | NA | 0 | NA | NA |
Bodner et al. [7] | 2005 | 10 | 167 | 0 | 0 | 0 | NA |
Current series | 2007 | 14 | 141 (90–240) | 12.5 | 0 | 5 | 4 (3–7) |
NA, Not available
Da Vinci robotic use is being developed in foregut surgery, i.e. Heller myotomy and gastric cancer resections [38–40]. Future developments will include technologies of information systems, virtual reality, and micro-robotics [41].
In conclusion, our preliminary experience with 94 cases is very encouraging. The da Vinci system is safe. Surgical outcome is good and patients’ satisfaction is rated high. Future developments in gastrointestinal robotic surgery should include cost analysis studies and evaluations of quality of life outcomes.
Footnotes
F.-A. Wassmer is deceased.
An erratum to this article can be found at http://dx.doi.org/10.1007/s11701-008-0068-8
References
- 1.Mouret P. How I developed laparoscopic cholecystectomy. Ann Acad Med. 1996;25(5):744–747. [PubMed] [Google Scholar]
- 2.Himpens J, Leman G, Cadière GB. Telesurgical laparoscopic cholecystectomy. Surg Endosc. 1998;12(8):1091. doi: 10.1007/s004649900788. [DOI] [PubMed] [Google Scholar]
- 3.Cadière GB, Himpens J, Germay O. Feasibility of robotic laparoscopic surgery: 146 cases. World J Surg. 2001;25(11):1467–1477. doi: 10.1007/s00268-001-0132-2. [DOI] [PubMed] [Google Scholar]
- 4.Chitwood WR, Nifong LW, Chapman WHH. Robotic surgical training in an academic institution. Ann Surg. 2001;234(4):475–486. doi: 10.1097/00000658-200110000-00007. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Perez A, Zinner MJ, Ashley SW, Brooks DC, Whang EE. What is the value of robotic technology in gastrointestinal surgery? Surg Endosc. 2003;17(5):811–813. doi: 10.1007/s00464-002-8561-z. [DOI] [PubMed] [Google Scholar]
- 6.Giulanotti PC, Coratti A, Angelini M. Robotics in general surgery. Arch Surg. 2003;138(7):77–784. doi: 10.1001/archsurg.138.7.777. [DOI] [PubMed] [Google Scholar]
- 7.Bodner J, Augustin F, Wykypiel H. The da Vinci robotic system for general surgical applications: a critical interim appraisal. Swiss Med Wkly. 2005;135(45–46):674–678. doi: 10.4414/smw.2005.11022. [DOI] [PubMed] [Google Scholar]
- 8.D’Annibale A, Orsini C, Morpurgo E, Sovernigo G. Robotic surgery: considerations after 250 procedures. Chit Ital. 2006;58(1):5–14. [PubMed] [Google Scholar]
- 9.Ballantyne GH. Telerobotic gastrointestinal surgery: phase 2-safety and efficacy. Surg Endosc. 2007;21(7):1054–1062. doi: 10.1007/s00464-006-9130-7. [DOI] [PubMed] [Google Scholar]
- 10.Gutt CN, Oniu T, Mehrabi A, Kashifi A, Schemmer P, Büchler MW. Robot-assisted abdominal surgery. Br J Surg. 2004;91(11):1390–1397. doi: 10.1002/bjs.4700. [DOI] [PubMed] [Google Scholar]
- 11.El Nakadi I, Mélot C, Closset J. Evaluation of da Vinci Nissen fundoplication clinical results and cost minimization. World J Surg. 2006;30(6):1050–1054. doi: 10.1007/s00268-005-7950-6. [DOI] [PubMed] [Google Scholar]
- 12.Morino M, Pellegrino L, Giaccone C, Garrone C, Rebecchi F. Randomized clinical trial of robot-assisted versus laparoscopic Nissen fundoplication. Br J Surg. 2006;93(5):553–558. doi: 10.1002/bjs.5325. [DOI] [PubMed] [Google Scholar]
- 13.Müller-Stich BP, Reiter MA, Wente MN. Robot-assisted versus conventional laparoscopic fundoplication: short-term outcome of a pilot randomized controlled trial. Surg Endosc. 2007;21(10):1800–1805. doi: 10.1007/s00464-007-9268-y. [DOI] [PubMed] [Google Scholar]
- 14.Rawlings AL, Woodland JH, Vegunta RK, Crawford DL. Robotic versus laparoscopic colectomy. Surg Endosc. 2007;21(10):1701–1708. doi: 10.1007/s00464-007-9231-y. [DOI] [PubMed] [Google Scholar]
- 15.Heemskerk J, van Gemert WG, Greve JW, Bouvy ND. Robot-assisted versus conventional laparoscopic Nissen fundoplication. Surg Laparosc Endosc Percutan Tech. 2007;17(1):1–4. doi: 10.1097/01.sle.0000213756.76761.b7. [DOI] [PubMed] [Google Scholar]
- 16.Taylor GW, Jayne DG. Robotic applications in abdominal surgery: their limitations and future developments. Int J Med Robotics Comput Assist Surg. 2007;3:30–34. doi: 10.1002/rcs.120. [DOI] [PubMed] [Google Scholar]
- 17.Weber PA, Merola S, Wasielewski A, Ballantyne GH. Telerobotic-assisted laparoscopic right and sigmoid colectomies for benign disease. Dis Colon Rectum. 2002;45(12):1689–1696. doi: 10.1007/s10350-004-7261-2. [DOI] [PubMed] [Google Scholar]
- 18.Delaney CP, Lynch AC, Senagore AJ, Fazio VW. Comparison of robotically performed and traditional laparoscopic colorectal surgery. Dis Colon Rectum. 2003;46(12):1633–1639. doi: 10.1007/BF02660768. [DOI] [PubMed] [Google Scholar]
- 19.Anvari M, Birch DW, Bamehriz F, Gryfe R, Chapman T. Robotic-assisted laparoscopic colorectal surgery. Surg Laparosc Endosc Percutan Tech. 2004;14(6):311–315. doi: 10.1097/01.sle.0000148473.05042.8f. [DOI] [PubMed] [Google Scholar]
- 20.D’Annibale A, Morpurgo E, Fiscon V. Robotic and laparoscopic surgery for treatment of colorectal diseases. Dis Colon Rectum. 2004;47(12):2161–2168. doi: 10.1007/s10350-004-0711-z. [DOI] [PubMed] [Google Scholar]
- 21.Woeste G, Bechstein WO, Wullstein C. Does telerobotic assistance improve laparoscopic colorectal surgery? Int J Colorectal Dis. 2005;20(3):253–257. doi: 10.1007/s00384-004-0671-8. [DOI] [PubMed] [Google Scholar]
- 22.Braumann C, Jacobi CA, Menenakos C, Borchert U, Rueckert JC, Mueller JM. Computer-assisted laparoscopic colon resection with the da Vinci system: our first experiences. Dis Colon Rectum. 2005;48(9):1820–1827. doi: 10.1007/s10350-005-0121-x. [DOI] [PubMed] [Google Scholar]
- 23.DeNoto G, Rubach E, Ravikumar TS. A standardized technique for robotically performed sigmoid colectomy. J Laparoendosc Adv Surg Tech. 2006;16(6):551–556. doi: 10.1089/lap.2006.16.551. [DOI] [PubMed] [Google Scholar]
- 24.Rawlings AL, Woodland JH, Crawford DL. Telerobotic surgery for right and sigmoid colectomies: 30 consecutive cases. Surg Endosc. 2006;20(11):1713–1718. doi: 10.1007/s00464-005-0771-8. [DOI] [PubMed] [Google Scholar]
- 25.Pigazzi A, Ellenhorn JDL, Ballantyne GH, Paz IB. Robotic-assisted laparoscopic low anterior resection with total mesorectal excision for rectal cancer. Surg Endosc. 2006;20(10):1521–1525. doi: 10.1007/s00464-005-0855-5. [DOI] [PubMed] [Google Scholar]
- 26.Chapman WH, Young JA, Albrecht RJ. Robotic Nissen fundoplication: alternative surgical technique for the treatment of gastroesophageal reflux disease. J Adv Laparoendosc Adv Surg Tech. 2001;11(1):27–30. doi: 10.1089/10926420150502904. [DOI] [PubMed] [Google Scholar]
- 27.Benincà G, Garrone C, Rebecchi F, Giaccone C, Morino M. Chirurgia laparoscopica robot-assistita. Risultati preliminary del nostro centro. Chir Ital. 2003;55(3):321–331. [PubMed] [Google Scholar]
- 28.Hanly EJ, Talamini MA. Robotic abdominal surgery. Am J Surg. 2004;188(suppl):19S–26S. doi: 10.1016/j.amjsurg.2004.08.020. [DOI] [PubMed] [Google Scholar]
- 29.Hubens G, Ruppert M, Balliu L, Vaneerdeweg W. What have we learnt after two years working with the da Vinci robot system in digestive surgery? Acta Chir Belg. 2004;104(6):609–614. doi: 10.1080/00015458.2004.11679629. [DOI] [PubMed] [Google Scholar]
- 30.Anvari M, McKinley C, Stein H. Establishment of the world first telerobotic remote surgical service. Ann Surg. 2005;241(3):460–464. doi: 10.1097/01.sla.0000154456.69815.ee. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.D’Annibale A, Orsini C, MOrpurgo E, Sovernico G. La chirurgia robotica. Conisderazioni dopo 250 interventi. Chir Ital. 2006;58(1):5–14. [PubMed] [Google Scholar]
- 32.Heemskerk J, van Gmert WG, Greve JW, Bouvy ND. Robot-assisted versus conventional laparoscopic Nissen fundoplication. Surg Laparosc Endosc Percutan Tech. 2007;17(1):1–4. doi: 10.1097/01.sle.0000213756.76761.b7. [DOI] [PubMed] [Google Scholar]
- 33.Mühlemann G, Klaus A, Kirchmayr W. Da Vinci robotic-assisted bariatric surgery: is it justified in a routine setting. Obes Surg. 2003;13(6):848–854. doi: 10.1381/096089203322618632. [DOI] [PubMed] [Google Scholar]
- 34.Jacobsen G, Berger R, Horgan S. The role of robotic surgery in morbid obesity. J Laparoendosc Adv Surg Tech. 2003;13(4):279–283. doi: 10.1089/109264203322333610. [DOI] [PubMed] [Google Scholar]
- 35.Nguyen NT, Hinojosa MW, Finley D, Stevens M, Paya M. Application of robotics in general surgery: initial experience. Am Surg. 2004;70(10):914–917. [PubMed] [Google Scholar]
- 36.Parini U, Fabozzi M, Brachet Contul R. Laparoscopic gastric bypass performed with the da Vinci intuitive robotic system: preliminary experience. Surg Endosc. 2006;20:1851–1857. doi: 10.1007/s00464-004-9146-9. [DOI] [PubMed] [Google Scholar]
- 37.Mohr CJ, Nadzam GS, Alami RS, Snachez BR, Curet MJ. Totally robotic Roux-en-Y gastric bypass: results from 75 patients. Obes Surg. 2006;16(6):690–696. doi: 10.1381/096089206777346826. [DOI] [PubMed] [Google Scholar]
- 38.Kakeji Y, Konishi K, Ieiri S. Robotic laparoscopic distal gastrectomy: a comparison of the da Vinci and Zeus systems. Int J Med Robot Comput Ass Surg. 2006;2(4):299–304. doi: 10.1002/rcs.104. [DOI] [PubMed] [Google Scholar]
- 39.Iqbal A, Haider M, Desai K. Technique and follow-up of minimally Heller myotomy for achalasia. Surg Endosc. 2006;20(3):394–401. doi: 10.1007/s00464-005-0069-x. [DOI] [PubMed] [Google Scholar]
- 40.Anderson C, Ellenhorn J, Hellan M, Pigazzi A. Pilot series of robot-assisted laparoscopic subtotal gastrectomy with extended lymphadenectomy for gastric cancer. Surg Endosc. 2007;21(9):1662–1666. doi: 10.1007/s00464-007-9266-0. [DOI] [PubMed] [Google Scholar]
- 41.Satava RM. Looking forward. Surg Endosc. 2006;20:S503–S504. doi: 10.1007/s00464-006-0057-9. [DOI] [PubMed] [Google Scholar]