Abstract
Objective:
In this study, we sought to determine differences in estimations of surface area made by classical vertical uniform random (VUR) section series and vertical section series obtained perpendicular to a fixed horizontal plane.
Materials and Methods:
One volunteer subject (male, 25 years of age) with no neurological deficit was chosen at random from a bank of controls in the magnetic resonance (MR) image data library of the Department of Radiology. First, a soccer ball with known geometrical features (radius: 9.75 cm) was imaged using a T1-weighted MR scanner at 5-mm thickness (total 40 sections) to test the validity and reliability of surface area and volume measurements obtained via stereological methods. Second, T1-weighted MR section profiles were obtained from a volunteer individual. Surface area and volume estimation procedures were carried out using the Stereo Investigator 6, MicroBright-Field, Inc., USA.
Conclusions:
We determined that there are no differences in either surface area or volume estimations made using VUR sections and direct vertical sections. We have performed an exhaustive series analysis with a variety of objects.
Keywords: Calculating surface area, Cycloids, Stereology, Volume estimation
Özet
Amaç:
Bu çalııma, klasik dikey düzenli rastgele (DDR) seri kesitler ile yatay düzleme dik olan dikey seri sabit kesitlerin ölçümleri arasında fark olup olmadııını anlamak için yapıldı.
Gereç ve Yöntem:
Magnetik rezonans (MR) resimlerinin bulunduıu Radyoloji bolumu arıivi kontrol bankasından rasgele alınan ve hicbir norolojik hasarı bulunmayan gonullu bir kiıi (erkek, 25 yaıında) secildi. İlk olarak geometrik özellikleri bilinen (yarıçap: 9.75 cm) futbol topunu T1-weigthed MR cihazı kullanılarak 5 mm kalınlııında MR görüntüleri (toplam: 40 kesit) alınarak yüzey alanı ve hacim hesaplama sonuçlarının stereolojik metot ile doıruluıu ve güvenirliliıi test edildi. İkinci olarak T-1 weigthed MR tarayıcı cihazı kesit profilleri gönüllü bireyden elde edildi. Yüzey alanı ve hacim hesaplama prosedürleri Stereo Investigator 6. MicroBrightField. Inc. USA. Kullanılarak yapıldı.
Sonuç:
Çalıımamız sonucunda, ilgilenilen geometrik ıekillerin enine ve boyuna kesitlerinde DDR kesitler ile direk dikey kesitler arasında hem yüzey alanı hesaplanması açısından hem de hacim hesaplanması açısından hiçbir farlılık bulunamamııtır.
Introduction
Quantitative examination of human cerebral cortex using a variety of methodological approaches has provided useful information in clinical studies and improved our understanding of the structure-function relationship. These techniques are based on in vivo magnetic resonance (MR) images. One such method is stereology, which is a sampling technique used to generate mathematically unbiased estimates of the geometric properties of three-dimensional structures based on two-dimensional slices of the object [1]. One of the most important quantitative parameters is the surface area, which is an important value in many areas of biology, such as the interface between capillaries and tissues, microvilli and the intestinal lumen, inspired air and dissolved gases in the alveoli, as well as connections between neurons, glial cells and synapses [2]. Useful techniques for estimating the surface area of complex objects have been produced using isotropic uniform random (IUR) sectioning [3] and vertical uniform random (VUR) sectioning approaches [4]. These methods have been successfully applied to a variety of biological tissues and images [5–7]. Although it is theoretically possible to use both IUR and VUR sectioning procedures to estimate surface area efficiently and without bias, this has proved difficult in practice, particularly when considering in vitro MR sectioning. For this reason, few studies have been published on this subject [8–9].
In this study, we sought to determine any differences between estimations of surface area made using classical VUR section series and those made using vertical section series that were obtained perpendicular to a fixed horizontal plane.
Materials and Methods
Subjects
One volunteer subject (male, age 25) with no neurological deficit was chosen at random from a bank of controls in the MR image data library in the Department of Radiology, Medical Faculty, Ataturk University, Erzurum. The ethics committee at the Medical Faculty, Ataturk University approved this study.
Collection of Magnetic Resonance Images
First, a soccer ball with known geometrical features (radius: 9.75 cm) was imaged using a T1-weighted MR scanner at 5-mm thickness (total 40 sections) to test the validity and reliability of the surface area and volume measurements obtained using stereological methods.
Second, T1-weighted MR section profiles were obtained from a volunteer individual. The right sagittal axis of the volunteer’s brain was assigned a starting point called “zero degrees” (0°), and then the whole brain was scanned with MR perpendicular to the axial plane in 5-mm thick sections (slice gap: 0 mm). The same process was applied using all other interesting angles at a systematic interval of 10° in the same direction (perpendicular to the axial plane). Approximately 540 images were obtained from the subsequent series (30 images from 0°, 30 images from 10°, etc.), and the collection consisted of images obtained at angels of 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160° and 170°.
Stereological software
Surface area and volume estimation procedures were applied using the Stereo Investigator 6, MicroBrightField Inc., USA.
Image data
MR image data were transferred to a workstation and converted from DICOM in order to estimate the surface area and volume of various structures using stereological methods.
Sampling Procedures
I. Sampling for a soccer ball
Forty section images (section thickness, 5 mm) obtained by scanning throughout a soccer ball without applying any sampling procedure were used for both stereological analyses and calculation according to the formulas for volume and surface area of a sphere.
II. Vertical Uniform Random Sampling (VURS) Protocol for MR Images
After all of the MR images were transferred to a workstation and converted from DICOM, a sampling procedure was applied according to stereological principles described in the VURS protocol (Figure 1, 2).
Figure 1.
The principle of the vertical uniform section (VUR) procedure is shown. Vertical uniform random sampling (VURS), used in the present study, is illustrated (boxed image-see Figure 2). The object of interest is laid parallel to the horizontal plane and the object is cut perpendicularly in a random manner. The resulting vertical sections are placed on a transverse plane that is parallel to the horizontal plane. It is important that the object be placed in the same direction (0°) as the previously detected internal marker. VUR sections are obtained by uniformly, randomly and systematically rotating a knife. Alternatively, vertical sections may be obtained by cutting the object perpendicular to the horizontal plane. These sections are uniformly and randomly rotated and have a systematic uniform random position. In the next step, these sections are placed over the other sections, and finally they are cut with a knife at a stable position. Because the second method cannot be applied to in vivo studies, it was not used in the current study.
Figure 2.
The vertical uniform random strategy used in this study. First, a whole brain was scanned to produce 5 mm T1-weighted consecutive MRI sections at an angle of 0° (Sagittal: perpendicular to horizontal axis). Then the same procedure was applied to all angles separately (From angle of 10° to 170°). This resulted in approximately 540 section profiles from one brain (31 sections at a sagittal angle of 0°, 30 sections at an angle of 10°, etc.). Second, a systematic random sampling procedure was carried out in order to obtain sections. A total of 18 series (angles of 0°–170°) was divided into six groups. Thus every group contained three series, for example the 1st, 2nd and 3rd series consisted of angles of 0°, 10° and 20°. Finally, the systematic interval at 30° was determined and random sampling was performed at angles of 0° (Table 3), −10° (Table 2) and −20° (Table 1) in the first, second and third VURS respectively. For example, we chose the 1st, 7th, 13th 19th and 25th section profiles from the 20° series, the 2nd, 8th, 14th 20th and 26th section profiles from the 50° series, the 3rd, 9th, 15th 21st and 27th section profiles from the 80° series, and so on. Procedures for estimating both surface area and volume were applied to 30 section profiles according to stereological principles.
In this study, a systematic range of 30° was accepted. In the first sampling procedure (VURS-1), randomness began at 20° (Table 1, Figure 2). The first image was taken from first section at 20°, the second image was taken from second section at 50°, the third image was taken from second section at 80°, and so on. All sampling procedures at this stage are summarized in Table 1 (Figure 2).
Table 1.
The first vertical uniform random sampling procedure (VURS-1); randomness was 20°
Section No: | Angle: | Section Order: | ||||
---|---|---|---|---|---|---|
1 | 0° | - | - | - | - | - |
2 | 10° | - | - | - | - | - |
3 | 20° | 1 | 7 | 13 | 19 | 25 |
4 | 30° | - | - | - | - | - |
5 | 40° | - | - | - | - | - |
6 | 50° | 2 | 8 | 14 | 20 | 26 |
7 | 60° | - | - | - | - | - |
8 | 70° | - | - | - | - | - |
9 | 80° | 3 | 9 | 15 | 21 | 27 |
10 | 90° | - | - | - | - | - |
11 | 100° | - | - | - | - | - |
12 | 110° | 4 | 10 | 16 | 22 | 28 |
13 | 120° | - | - | - | - | - |
14 | 130° | - | - | - | - | - |
15 | 140° | 5 | 11 | 17 | 23 | 29 |
16 | 150° | - | - | - | - | - |
17 | 160° | - | - | - | - | - |
18 | 170° | 6 | 12 | 18 | 24 | 30 |
In the second sampling stage (VURS-2), the systematic range was the same (30° was considered acceptable), but randomness began at 10°. All sampling procedures during the second stage are summarized in Table 2.
Table 2.
The second vertical uniform random sampling procedure (VURS-2); randomness was 10°
Section No: | Angle: | Section Order: | ||||
---|---|---|---|---|---|---|
1 | 0° | - | - | - | - | - |
2 | 10° | 1 | 7 | 13 | 19 | 25 |
3 | 20° | - | - | - | - | - |
4 | 30° | - | - | - | - | - |
5 | 40° | 2 | 8 | 14 | 20 | 26 |
6 | 50° | - | - | - | - | - |
7 | 60° | - | - | - | - | - |
8 | 70° | 3 | 9 | 15 | 21 | 27 |
9 | 80° | - | - | - | - | - |
10 | 90° | - | - | - | - | - |
11 | 100° | 4 | 10 | 16 | 22 | 28 |
12 | 110° | - | - | - | - | - |
13 | 120° | - | - | - | - | - |
14 | 130° | 5 | 11 | 17 | 23 | 29 |
15 | 140° | - | - | - | - | - |
16 | 150° | - | - | - | - | - |
17 | 160° | 6 | 12 | 18 | 24 | - |
18 | 170° | - | - | - | - | - |
In the third sampling stage (VURS-3), the systematic range was the same (30° was considered acceptable), but randomness began at 0°. All sampling procedures during the third stage are summarized in Table 3.
Table 3.
The third vertical uniform random sampling (VURS-3); procedure (Systematic range: 30°, randomness: 0°)
Section No: | Angle: | Section Order: | ||||
---|---|---|---|---|---|---|
1 | 0° | 1 | 7 | 13 | 19 | 25 |
2 | 10° | - | - | - | - | - |
3 | 20° | - | - | - | - | - |
4 | 30° | 2 | 8 | 14 | 20 | 26 |
5 | 40° | - | - | - | - | - |
6 | 50° | - | - | - | - | - |
7 | 60° | 3 | 9 | 15 | 21 | 27 |
8 | 70° | - | - | - | - | - |
9 | 80° | - | - | - | - | - |
10 | 90° | 4 | 10 | 16 | 22 | 28 |
11 | 100° | - | - | - | - | - |
12 | 110° | - | - | - | * | - |
13 | 120° | 5 | 11 | 17 | 23 | 29 |
14 | 130° | - | - | - | - | |
15 | 140° | - | - | - | - | - |
16 | 150° | 6 | 12 | 18 | 24 | - |
17 | 160° | - | - | - | - | - |
18 | 170° | - | - | - | - | - |
The volume and surface area formulas were applied separately to section images obtained as described above according to stereological principles (Figure 3).
Figure 3.
A) a sagittal MR image used in the study. This image was transmitted to a PC with a stereo-investigator. B) the same image was superimposed on a point counting grid (for volume estimation) and intersections (for surface area estimation) together.
II. Use of the Modified Vertical Section Procedure on MR Section Profiles
After all MR images were transferred to a workstation and converted from DICOM, each image was separately assessed to estimate surface areas and volumes. All section profiles obtained were perpendicular to a fixed horizontal plane in each angel (0°, 10, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160° and 170°).
The volume and surface area formulas were applied according to stereological principles to the section images as described above (Figure 4).
Figure 4.
In the first image, all planes, related to this study are illustrated. Serial sections (MR images in the study) at the fixed plane (angle of 0°, sagittal: Perpendicular to horizontal axis) were handled. All serial images (31 section profiles) in which the brain was viewed are shown. Estimates of volume and surface area were made according to stereological principles.
Stereological Estimations
I. Surface Area and Volume Calculation for a Soccer Ball
The ball used in our calculations was sphere-shaped with a radius of 9.75 cm. Its volume and surface area can be calculated by the volume and surface area formulas for a sphere (V=4/3 ·π·r3, SA= 4·π·r2).
II. Surface Area and Volume Estimation for a Scroll Ball and MR sections
Volume estimation
A volume estimation of any structure of interest can be obtained efficiently according to the principle of Cavalieri [10] regardless of shape or size. The volumes for each section were estimated by the following formula:
where V is the volume of the object of interest (tumor) in one section plane, t is the section thickness, a/p is the interpoint area, and ∑P is the number of points touching the tumor in that section. After this formula is applied as described in other sections, the estimate of total volume can be obtained from:
Surface area estimation
The surface area any structure may be estimated according to the principle of surface area from vertical sections [4] regardless of its shape or size.
The surface area was estimated using the following formula: where T is the slice separation, a/l is the area per length of a cycloid, Li is the number of intersections generated on the ith slice and j is the total number of slices.
Estimation of the surface area per unit volume
This method is used to estimate the surface area per unit volume. The surface area per unit volume was estimated using the following formula [4]:
where I is the number of intersections counted and L is the total length of all cycloids in all slices. Pi is the point count per sample slice.
Error Prediction Estimations
I. Error Predictions for the Cavalieri Estimation:
The point density of the point counting grid was designed to obtain an appropriate coefficient of error (CE) for images of the serial sections (Table 4). CE and coefficient of variation (CV) were estimated according to Gundersen and Jensen’s formula [10].
Table 4.
An example of total volume and CE of a brain section in our study (angels of 60)
Section Number | Number of Point (P) | A PXP |
B PXPİ |
C PXPİ+1 |
---|---|---|---|---|
1 | 4 | 16 | 88 | 108 |
2 | 22 | 484 | 594 | 748 |
3 | 27 | 729 | 918 | 1134 |
4 | 34 | 1156 | 1428 | 1496 |
5 | 42 | 1764 | 1848 | 2142 |
6 | 44 | 1936 | 2244 | 1980 |
7 | 51 | 2601 | 2295 | 2448 |
8 | 45 | 2025 | 2160 | 2205 |
9 | 48 | 2304 | 2352 | 2400 |
10 | 49 | 2401 | 2450 | 2597 |
11 | 50 | 2500 | 2650 | 2450 |
12 | 53 | 2809 | 2597 | 2703 |
13 | 49 | 2401 | 2499 | 2254 |
14 | 51 | 2601 | 2346 | 2346 |
15 | 46 | 2116 | 2116 | 2438 |
16 | 46 | 2116 | 2438 | 2392 |
17 | 53 | 2809 | 2756 | 2650 |
18 | 52 | 2704 | 2600 | 2600 |
19 | 50 | 2500 | 2500 | 2100 |
20 | 50 | 2500 | 2100 | 2250 |
21 | 42 | 1764 | 1890 | 2100 |
22 | 45 | 2025 | 2250 | 2205 |
23 | 50 | 2500 | 2450 | 2100 |
24 | 49 | 2401 | 2058 | 1764 |
25 | 42 | 1764 | 1512 | 1344 |
26 | 36 | 1296 | 1152 | 756 |
27 | 32 | 1024 | 672 | 576 |
28 | 21 | 441 | 378 | 231 |
29 | 18 | 324 | 198 | 162 |
30 | 11 | 121 | 99 | 44 |
31 | 9 | 81 | 36 | 0 |
32 | 4 | 16 | 0 | 0 |
Total | 1225 | 54229 | 53674 | 52723 |
Noise is a value representing the complexity of the examined cut surface area of the specimen, is equivalent to the mean boundary length of the profiles divided by the square root of their mean area, n is the section number that is examined, and ∑P the number of points touching each whole section.
Where indicates variance of total area in the systematic random sampling (SRS). These data indicate the sufficient number of sections required to obtain an appropriate variation for section samples. A, B and C are the total numerical values for the data in the related column of Table 1.
CE is the last calculated value. The highest limit of CE that is generally accepted is 5% [10].
II. Error Predictions for the Surface Area Estimation
Results
We obtained approximately 540 images from the subsequent series (30 images from 0°, 30 images from 10°, etc.) consisting of angels of 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160° and 170°. All stereological sectioning procedures are summarized in Table 1, Table 2, Table 3, Figure 1 and 2. Our stereological estimations of total volume and surface area were significantly similar (P< 0.05) according to directly vertical sections and VURS sections (Table 6).
Table 6.
Results of estimated brain surface area and volume on MR images both obtained according to vertical uniform random sampling procedure and directly vertical section that was perpendicular to a fixed horizontal plane at the angle of 0°–180° separately
Angels | Number of Section | Test Point Area Per Cycloids Length -cm2 | Number of Intersection | Surface Area-cm2 | Volume Associated With Test Point-cm3 | Number of Test Point | Volume-cm3 |
---|---|---|---|---|---|---|---|
0 | 31 | 1,32 | 1001 | 1321,32 | 0,98 | 1260 | 1234,8 |
10 | 31 | 1,32 | 1031 | 1360,92 | 0,98 | 1272 | 1246,56 |
20 | 29 | 1,32 | 999 | 1318,68 | 0,98 | 1230 | 1205,4 |
30 | 30 | 1,32 | 1034 | 1364,88 | 0,98 | 1281 | 1255,38 |
40 | 30 | 1,32 | 1040 | 1372,8 | 0,98 | 1229 | 1204,42 |
50 | 31 | 1,32 | 1026 | 1354,32 | 0,98 | 1272 | 1246,56 |
60 | 32 | 1,32 | 1024 | 1351,68 | 0,98 | 1225 | 1200,5 |
70 | 31 | 1,32 | 1033 | 1363,56 | 0,98 | 1235 | 1210,3 |
80 | 32 | 1,32 | 1007 | 1329,24 | 0,98 | 1278 | 1252,44 |
90 | 32 | 1,32 | 1035 | 1366,2 | 0,98 | 1308 | 1281,84 |
100 | 32 | 1,32 | 933 | 1231,56 | 0,98 | 1291 | 1265,18 |
110 | 33 | 1,32 | 1003 | 1323,96 | 0,98 | 1231 | 1206,38 |
120 | 32 | 1,32 | 1020 | 1346,4 | 0,98 | 1284 | 1258,32 |
130 | 32 | 1,32 | 1027 | 1355,64 | 0,98 | 1293 | 1267,14 |
140 | 30 | 1,32 | 1036 | 1367,52 | 0,98 | 1303 | 1276,94 |
150 | 29 | 1,32 | 1043 | 1376,76 | 0,98 | 1221 | 1196,58 |
160 | 29 | 1,32 | 1047 | 1382,04 | 0,98 | 1237 | 1212,26 |
170 | 30 | 1,32 | 1029 | 1358,28 | 0,98 | 1286 | 1260,28 |
VURS-1 | 29 | 1,32 | 1028 | 1356,96 | 0,98 | 1279 | 1253,42 |
VURS-2 | 29 | 1,32 | 1010 | 1333,2 | 0,98 | 1269 | 1243,62 |
VURS-3 | 30 | 1,32 | 1029 | 1358,28 | 0,98 | 1279 | 1253,42 |
Discussion
Stereology is an unbiased sampling technique whereby the object of interest is sectioned into a series of two-dimensional slices. This method can generate important data about the three-dimensional structure the object [8].
Human beings have long been interested in the regular and macroscopic metric parameters of the three-dimensional universe, as well as microscopic and irregular parameters such as volume, number, length and surface area. For structures such as cones or cylinders, volume and surface area can be easily calculated by applying known formulas. However, if a structure has irregular geometrical features, then complex processes are inevitability required. Currently, stereological methods are among the techniques suggested to estimate the metric properties of irregular sutures. It is easy, efficient and practical to apply some of these methods, such as volume estimation using the Cavalieri method, both in vivo and in vitro. However, determination of the surface area of complex and irregularly-shaped objects, especially objects in living organisms, is very difficult and not practical in terms of sampling procedure. Stereological principles for estimating surface area consist of either isotropic uniform random sampling (IURS) or VURS procedures [4].
The VURS procedure described by others and in our study is both difficult to understand and not practical to apply, particularly in in vivo situations, despite the fact that it is an efficient and useful approach to estimate the surface area of interesting objects. The most important disadvantage is the increased workload in the processing of the tissue due to the embedment and re-embedment [12]. This burden may be tolerated in macroscopic or perhaps microscopic studies that are conducted in vitro, but in radiological studies, to obtain and analyze VUR is not practical for a typical radiology unit. In our study, we found that approximately 540 sections, 5-mm thick, were required for the VURS procedure.
We estimated brain surface area from MR images that were obtained according to the VURS procedure as described in Materials and Methods. Directly vertical sections were obtained perpendicular to a fixed horizontal plane at angles of 0°–180°. We determined that there is no difference in the estimation of surface area or volume between VURS sections and directly vertical sections using an exhaustive series of a test object. We found no difference between surface area estimates using VURS sections or directly vertical sections in our empirical study. This result is consistent with a previous study that was carried out by Robert N, et al. (2000) [9]. In this study, cerebral hemispheres were sampled with 12 exhaustive series of vertical sections at 15° intervals about a fixed vertical axis [9] and surface area estimations were done with cycloid test lines [4]. Our study is similar to the study of Robert N, et al. (2000) with respect to the use of directly vertical sections at different angels to estimate surface area, but we also tried to obtain MR sections for estimating the surface area according to a vertical uniform random sampling procedure in order to compare with two approaches.
Figure 5.
Surface area and volume values estimated in the study.
Table 5.
An example of total surface area and CE of a brain section in our study (angels of 60)
Section Number | Number of Intersection (G) | A GXG |
B GXGi |
C GXGİ+1 |
---|---|---|---|---|
1 | 13 | 169 | 299 | 325 |
2 | 23 | 529 | 575 | 690 |
3 | 25 | 625 | 750 | 725 |
4 | 30 | 900 | 870 | 1080 |
5 | 29 | 841 | 1044 | 1102 |
6 | 36 | 1296 | 1368 | 1656 |
7 | 38 | 1444 | 1748 | 1482 |
8 | 46 | 2116 | 1794 | 1656 |
9 | 39 | 1521 | 1404 | 1755 |
10 | 36 | 1296 | 1620 | 1584 |
11 | 45 | 2025 | 1980 | 1260 |
12 | 44 | 1936 | 1232 | 1408 |
13 | 28 | 784 | 896 | 952 |
14 | 32 | 1024 | 1088 | 1344 |
15 | 34 | 1156 | 1428 | 1496 |
16 | 42 | 1764 | 1848 | 1932 |
17 | 44 | 1936 | 2024 | 1540 |
18 | 46 | 2116 | 1610 | 1702 |
19 | 35 | 1225 | 1295 | 1120 |
20 | 37 | 1369 | 1184 | 1184 |
21 | 32 | 1024 | 1024 | 1312 |
22 | 32 | 1024 | 1312 | 1120 |
23 | 41 | 1681 | 1435 | 1394 |
24 | 35 | 1225 | 1190 | 1085 |
25 | 34 | 1156 | 1054 | 1156 |
26 | 31 | 961 | 1054 | 620 |
27 | 34 | 1156 | 680 | 748 |
28 | 20 | 400 | 440 | 420 |
29 | 22 | 484 | 462 | 308 |
30 | 21 | 441 | 294 | 126 |
31 | 14 | 196 | 84 | 0 |
32 | 6 | 36 | 0 | 0 |
A | B | C | ||
Total | 1024 | 35856 | 35086 | 34282 |
Footnotes
Conflict of interest statement: The authors declare that they have no conflict of interest to the publication of this article.
References
- 1.Ronan L, Doherty CP, Delanty N, et al. A reliable protocol for measurement of cerebral gyrification using stereology. Magn Reson Imaging. 2006;24:265–72. doi: 10.1016/j.mri.2005.10.033. [DOI] [PubMed] [Google Scholar]
- 2.Gokhale AM, Evans RA, Mackes JL, et al. Design-based estimation of surface area in thick tissue sections of arbitrary orientation using virtual cycloids. J Microsc. 2004;216:25–31. doi: 10.1111/j.0022-2720.2004.01392.x. [DOI] [PubMed] [Google Scholar]
- 3.Jørgen H, Gundersen G. Estimation of tubule or cylinder LV, SV, and VV on thick sections. J Microsc. 1979;117:333–45. doi: 10.1111/j.1365-2818.1979.tb04690.x. [DOI] [PubMed] [Google Scholar]
- 4.Baddeley AJ, Gundersen HJ, Cruz-Orive LM. Estimation of surface area from vertical sections. J Microsc. 1986;142:259–76. doi: 10.1111/j.1365-2818.1986.tb04282.x. [DOI] [PubMed] [Google Scholar]
- 5.Kubinova L, Janacek J. Estimating surface area by the isotropic fakir method from thick slices cut in an arbitrary direction. J Microsc. 1998;191:201–11. doi: 10.1046/j.1365-2818.1998.00356.x. [DOI] [PubMed] [Google Scholar]
- 6.Mattfeldt T, Mall G. Estimation of surface and length of anisotropic capillaries. J Microsc. 1984;153:181–90. doi: 10.1111/j.1365-2818.1984.tb00518.x. [DOI] [PubMed] [Google Scholar]
- 7.Nyengaard JR, Gundersen HJG. The isector: a simple and direct method for generating isotropic, uniform random sections from small specimens. J Microsc. 1992;1992;165:427–31. [Google Scholar]
- 8.Ronan L, Doherty CP, Delanty N, et al. Quantitative MRI: a reliable protocol for measurement of cerebral gyrification using stereology. Magn Reson Imaging. 2006;24:265–72. doi: 10.1016/j.mri.2005.10.033. [DOI] [PubMed] [Google Scholar]
- 9.Roberts N, Puddephat MJ, McNulty V. The benefit of stereology for quantitative radiology. Br J Radiol. 2000;73:679–97. doi: 10.1259/bjr.73.871.11089458. [DOI] [PubMed] [Google Scholar]
- 10.Gundersen HJ, Jensen EB. The efficiency of systematic sampling in stereology and its prediction. J Microsc. 1987;147:229–63. doi: 10.1111/j.1365-2818.1987.tb02837.x. [DOI] [PubMed] [Google Scholar]
- 11.Roberts N, Puddephat MJ, McNulty V. The benefit of stereology for quantitative radiology. Br J Radiol. 2000;73:679–97. doi: 10.1259/bjr.73.871.11089458. [DOI] [PubMed] [Google Scholar]
- 12.Dorph-Petersen K. Stereological estimation using vertical sections in a complex tissue. J Microsc. 1999;195:79–86. doi: 10.1046/j.1365-2818.1999.00471.x. [DOI] [PubMed] [Google Scholar]