A Stereological Assessment Method for Estimating the Surface Area of Cycloids

Bunyami Unal 1, Adem Kara 2,, Selina Aksak 1, Deniz Unal 1
PMCID: PMC4261337  PMID: 25610126

Abstract

Objective:

In this study, we sought to determine differences in estimations of surface area made by classical vertical uniform random (VUR) section series and vertical section series obtained perpendicular to a fixed horizontal plane.

Materials and Methods:

One volunteer subject (male, 25 years of age) with no neurological deficit was chosen at random from a bank of controls in the magnetic resonance (MR) image data library of the Department of Radiology. First, a soccer ball with known geometrical features (radius: 9.75 cm) was imaged using a T1-weighted MR scanner at 5-mm thickness (total 40 sections) to test the validity and reliability of surface area and volume measurements obtained via stereological methods. Second, T1-weighted MR section profiles were obtained from a volunteer individual. Surface area and volume estimation procedures were carried out using the Stereo Investigator 6, MicroBright-Field, Inc., USA.

Conclusions:

We determined that there are no differences in either surface area or volume estimations made using VUR sections and direct vertical sections. We have performed an exhaustive series analysis with a variety of objects.

Keywords: Calculating surface area, Cycloids, Stereology, Volume estimation

Introduction

Quantitative examination of human cerebral cortex using a variety of methodological approaches has provided useful information in clinical studies and improved our understanding of the structure-function relationship. These techniques are based on in vivo magnetic resonance (MR) images. One such method is stereology, which is a sampling technique used to generate mathematically unbiased estimates of the geometric properties of three-dimensional structures based on two-dimensional slices of the object [1]. One of the most important quantitative parameters is the surface area, which is an important value in many areas of biology, such as the interface between capillaries and tissues, microvilli and the intestinal lumen, inspired air and dissolved gases in the alveoli, as well as connections between neurons, glial cells and synapses [2]. Useful techniques for estimating the surface area of complex objects have been produced using isotropic uniform random (IUR) sectioning [3] and vertical uniform random (VUR) sectioning approaches [4]. These methods have been successfully applied to a variety of biological tissues and images [57]. Although it is theoretically possible to use both IUR and VUR sectioning procedures to estimate surface area efficiently and without bias, this has proved difficult in practice, particularly when considering in vitro MR sectioning. For this reason, few studies have been published on this subject [89].

In this study, we sought to determine any differences between estimations of surface area made using classical VUR section series and those made using vertical section series that were obtained perpendicular to a fixed horizontal plane.

Materials and Methods

Subjects

One volunteer subject (male, age 25) with no neurological deficit was chosen at random from a bank of controls in the MR image data library in the Department of Radiology, Medical Faculty, Ataturk University, Erzurum. The ethics committee at the Medical Faculty, Ataturk University approved this study.

Collection of Magnetic Resonance Images

First, a soccer ball with known geometrical features (radius: 9.75 cm) was imaged using a T1-weighted MR scanner at 5-mm thickness (total 40 sections) to test the validity and reliability of the surface area and volume measurements obtained using stereological methods.

Second, T1-weighted MR section profiles were obtained from a volunteer individual. The right sagittal axis of the volunteer’s brain was assigned a starting point called “zero degrees” (0°), and then the whole brain was scanned with MR perpendicular to the axial plane in 5-mm thick sections (slice gap: 0 mm). The same process was applied using all other interesting angles at a systematic interval of 10° in the same direction (perpendicular to the axial plane). Approximately 540 images were obtained from the subsequent series (30 images from 0°, 30 images from 10°, etc.), and the collection consisted of images obtained at angels of 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160° and 170°.

Stereological software

Surface area and volume estimation procedures were applied using the Stereo Investigator 6, MicroBrightField Inc., USA.

Image data

MR image data were transferred to a workstation and converted from DICOM in order to estimate the surface area and volume of various structures using stereological methods.

Sampling Procedures

I. Sampling for a soccer ball

Forty section images (section thickness, 5 mm) obtained by scanning throughout a soccer ball without applying any sampling procedure were used for both stereological analyses and calculation according to the formulas for volume and surface area of a sphere.

II. Vertical Uniform Random Sampling (VURS) Protocol for MR Images

After all of the MR images were transferred to a workstation and converted from DICOM, a sampling procedure was applied according to stereological principles described in the VURS protocol (Figure 1, 2).

Figure 1.

Figure 1.

The principle of the vertical uniform section (VUR) procedure is shown. Vertical uniform random sampling (VURS), used in the present study, is illustrated (boxed image-see Figure 2). The object of interest is laid parallel to the horizontal plane and the object is cut perpendicularly in a random manner. The resulting vertical sections are placed on a transverse plane that is parallel to the horizontal plane. It is important that the object be placed in the same direction (0°) as the previously detected internal marker. VUR sections are obtained by uniformly, randomly and systematically rotating a knife. Alternatively, vertical sections may be obtained by cutting the object perpendicular to the horizontal plane. These sections are uniformly and randomly rotated and have a systematic uniform random position. In the next step, these sections are placed over the other sections, and finally they are cut with a knife at a stable position. Because the second method cannot be applied to in vivo studies, it was not used in the current study.

Figure 2.

Figure 2.

The vertical uniform random strategy used in this study. First, a whole brain was scanned to produce 5 mm T1-weighted consecutive MRI sections at an angle of 0° (Sagittal: perpendicular to horizontal axis). Then the same procedure was applied to all angles separately (From angle of 10° to 170°). This resulted in approximately 540 section profiles from one brain (31 sections at a sagittal angle of 0°, 30 sections at an angle of 10°, etc.). Second, a systematic random sampling procedure was carried out in order to obtain sections. A total of 18 series (angles of 0°–170°) was divided into six groups. Thus every group contained three series, for example the 1st, 2nd and 3rd series consisted of angles of 0°, 10° and 20°. Finally, the systematic interval at 30° was determined and random sampling was performed at angles of 0° (Table 3), −10° (Table 2) and −20° (Table 1) in the first, second and third VURS respectively. For example, we chose the 1st, 7th, 13th 19th and 25th section profiles from the 20° series, the 2nd, 8th, 14th 20th and 26th section profiles from the 50° series, the 3rd, 9th, 15th 21st and 27th section profiles from the 80° series, and so on. Procedures for estimating both surface area and volume were applied to 30 section profiles according to stereological principles.

In this study, a systematic range of 30° was accepted. In the first sampling procedure (VURS-1), randomness began at 20° (Table 1, Figure 2). The first image was taken from first section at 20°, the second image was taken from second section at 50°, the third image was taken from second section at 80°, and so on. All sampling procedures at this stage are summarized in Table 1 (Figure 2).

Table 1.

The first vertical uniform random sampling procedure (VURS-1); randomness was 20°

Section No: Angle: Section Order:
1 - - - - -
2 10° - - - - -
3 20° 1 7 13 19 25
4 30° - - - - -
5 40° - - - - -
6 50° 2 8 14 20 26
7 60° - - - - -
8 70° - - - - -
9 80° 3 9 15 21 27
10 90° - - - - -
11 100° - - - - -
12 110° 4 10 16 22 28
13 120° - - - - -
14 130° - - - - -
15 140° 5 11 17 23 29
16 150° - - - - -
17 160° - - - - -
18 170° 6 12 18 24 30

In the second sampling stage (VURS-2), the systematic range was the same (30° was considered acceptable), but randomness began at 10°. All sampling procedures during the second stage are summarized in Table 2.

Table 2.

The second vertical uniform random sampling procedure (VURS-2); randomness was 10°

Section No: Angle: Section Order:
1 - - - - -
2 10° 1 7 13 19 25
3 20° - - - - -
4 30° - - - - -
5 40° 2 8 14 20 26
6 50° - - - - -
7 60° - - - - -
8 70° 3 9 15 21 27
9 80° - - - - -
10 90° - - - - -
11 100° 4 10 16 22 28
12 110° - - - - -
13 120° - - - - -
14 130° 5 11 17 23 29
15 140° - - - - -
16 150° - - - - -
17 160° 6 12 18 24 -
18 170° - - - - -

In the third sampling stage (VURS-3), the systematic range was the same (30° was considered acceptable), but randomness began at 0°. All sampling procedures during the third stage are summarized in Table 3.

Table 3.

The third vertical uniform random sampling (VURS-3); procedure (Systematic range: 30°, randomness: 0°)

Section No: Angle: Section Order:
1 1 7 13 19 25
2 10° - - - - -
3 20° - - - - -
4 30° 2 8 14 20 26
5 40° - - - - -
6 50° - - - - -
7 60° 3 9 15 21 27
8 70° - - - - -
9 80° - - - - -
10 90° 4 10 16 22 28
11 100° - - - - -
12 110° - - - * -
13 120° 5 11 17 23 29
14 130° - - - -
15 140° - - - - -
16 150° 6 12 18 24 -
17 160° - - - - -
18 170° - - - - -

The volume and surface area formulas were applied separately to section images obtained as described above according to stereological principles (Figure 3).

Figure 3.

Figure 3.

A) a sagittal MR image used in the study. This image was transmitted to a PC with a stereo-investigator. B) the same image was superimposed on a point counting grid (for volume estimation) and intersections (for surface area estimation) together.

II. Use of the Modified Vertical Section Procedure on MR Section Profiles

After all MR images were transferred to a workstation and converted from DICOM, each image was separately assessed to estimate surface areas and volumes. All section profiles obtained were perpendicular to a fixed horizontal plane in each angel (0°, 10, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160° and 170°).

The volume and surface area formulas were applied according to stereological principles to the section images as described above (Figure 4).

Figure 4.

Figure 4.

In the first image, all planes, related to this study are illustrated. Serial sections (MR images in the study) at the fixed plane (angle of 0°, sagittal: Perpendicular to horizontal axis) were handled. All serial images (31 section profiles) in which the brain was viewed are shown. Estimates of volume and surface area were made according to stereological principles.

Stereological Estimations

I. Surface Area and Volume Calculation for a Soccer Ball

The ball used in our calculations was sphere-shaped with a radius of 9.75 cm. Its volume and surface area can be calculated by the volume and surface area formulas for a sphere (V=4/3 ·π·r3, SA= 4·π·r2).

II. Surface Area and Volume Estimation for a Scroll Ball and MR sections

Volume estimation

A volume estimation of any structure of interest can be obtained efficiently according to the principle of Cavalieri [10] regardless of shape or size. The volumes for each section were estimated by the following formula:

V^=t×ap×i=1mPi

where V is the volume of the object of interest (tumor) in one section plane, t is the section thickness, a/p is the interpoint area, and ∑P is the number of points touching the tumor in that section. After this formula is applied as described in other sections, the estimate of total volume can be obtained from:

V^total=V1+V2+Vn

Surface area estimation

The surface area any structure may be estimated according to the principle of surface area from vertical sections [4] regardless of its shape or size.

S^=2.T.(a/l).i=1jLi

The surface area was estimated using the following formula: where T is the slice separation, a/l is the area per length of a cycloid, Li is the number of intersections generated on the ith slice and j is the total number of slices.

Estimation of the surface area per unit volume

This method is used to estimate the surface area per unit volume. The surface area per unit volume was estimated using the following formula [4]:

S^V=2i=1nIilpi=1nPi

where I is the number of intersections counted and L is the total length of all cycloids in all slices. Pi is the point count per sample slice.

Error Prediction Estimations

I. Error Predictions for the Cavalieri Estimation:

The point density of the point counting grid was designed to obtain an appropriate coefficient of error (CE) for images of the serial sections (Table 4). CE and coefficient of variation (CV) were estimated according to Gundersen and Jensen’s formula [10].

Noise=0.0724×(b/a)×n×ΣP=0.0724×5×32×1225=71,67

Table 4.

An example of total volume and CE of a brain section in our study (angels of 60)

Section Number Number of Point (P) A
PXP
B
PXPİ
C
PXPİ+1
1 4 16 88 108
2 22 484 594 748
3 27 729 918 1134
4 34 1156 1428 1496
5 42 1764 1848 2142
6 44 1936 2244 1980
7 51 2601 2295 2448
8 45 2025 2160 2205
9 48 2304 2352 2400
10 49 2401 2450 2597
11 50 2500 2650 2450
12 53 2809 2597 2703
13 49 2401 2499 2254
14 51 2601 2346 2346
15 46 2116 2116 2438
16 46 2116 2438 2392
17 53 2809 2756 2650
18 52 2704 2600 2600
19 50 2500 2500 2100
20 50 2500 2100 2250
21 42 1764 1890 2100
22 45 2025 2250 2205
23 50 2500 2450 2100
24 49 2401 2058 1764
25 42 1764 1512 1344
26 36 1296 1152 756
27 32 1024 672 576
28 21 441 378 231
29 18 324 198 162
30 11 121 99 44
31 9 81 36 0
32 4 16 0 0
Total 1225 54229 53674 52723

Noise is a value representing the complexity of the examined cut surface area of the specimen, b/a is equivalent to the mean boundary length of the profiles divided by the square root of their mean area, n is the section number that is examined, and ∑P the number of points touching each whole section.

VarSRS(i=1na)=(3(ANoise)4B+C)/12=(3.(5422971,67)4×53674+52723/12=41,58

Where VarSRS(i=1na) indicates variance of total area in the systematic random sampling (SRS). These data indicate the sufficient number of sections required to obtain an appropriate variation for section samples. A, B and C are the total numerical values for the data in the related column of Table 1.

TotalVar=Noise+VarSRS=71,67+41,58=113,25
CE(ΣP)=TotalVarΣP=113,251225=0,0086

CE is the last calculated value. The highest limit of CE that is generally accepted is 5% [10].

II. Error Predictions for the Surface Area Estimation

VARSRS=3A4B+C12=3×358564×3508612=125,5
CE(S)=VARSRSi=1nIi=125,51024=0,012

Results

We obtained approximately 540 images from the subsequent series (30 images from 0°, 30 images from 10°, etc.) consisting of angels of 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160° and 170°. All stereological sectioning procedures are summarized in Table 1, Table 2, Table 3, Figure 1 and 2. Our stereological estimations of total volume and surface area were significantly similar (P< 0.05) according to directly vertical sections and VURS sections (Table 6).

Table 6.

Results of estimated brain surface area and volume on MR images both obtained according to vertical uniform random sampling procedure and directly vertical section that was perpendicular to a fixed horizontal plane at the angle of 0°–180° separately

Angels Number of Section Test Point Area Per Cycloids Length -cm2 Number of Intersection Surface Area-cm2 Volume Associated With Test Point-cm3 Number of Test Point Volume-cm3
0 31 1,32 1001 1321,32 0,98 1260 1234,8
10 31 1,32 1031 1360,92 0,98 1272 1246,56
20 29 1,32 999 1318,68 0,98 1230 1205,4
30 30 1,32 1034 1364,88 0,98 1281 1255,38
40 30 1,32 1040 1372,8 0,98 1229 1204,42
50 31 1,32 1026 1354,32 0,98 1272 1246,56
60 32 1,32 1024 1351,68 0,98 1225 1200,5
70 31 1,32 1033 1363,56 0,98 1235 1210,3
80 32 1,32 1007 1329,24 0,98 1278 1252,44
90 32 1,32 1035 1366,2 0,98 1308 1281,84
100 32 1,32 933 1231,56 0,98 1291 1265,18
110 33 1,32 1003 1323,96 0,98 1231 1206,38
120 32 1,32 1020 1346,4 0,98 1284 1258,32
130 32 1,32 1027 1355,64 0,98 1293 1267,14
140 30 1,32 1036 1367,52 0,98 1303 1276,94
150 29 1,32 1043 1376,76 0,98 1221 1196,58
160 29 1,32 1047 1382,04 0,98 1237 1212,26
170 30 1,32 1029 1358,28 0,98 1286 1260,28
VURS-1 29 1,32 1028 1356,96 0,98 1279 1253,42
VURS-2 29 1,32 1010 1333,2 0,98 1269 1243,62
VURS-3 30 1,32 1029 1358,28 0,98 1279 1253,42

Discussion

Stereology is an unbiased sampling technique whereby the object of interest is sectioned into a series of two-dimensional slices. This method can generate important data about the three-dimensional structure the object [8].

Human beings have long been interested in the regular and macroscopic metric parameters of the three-dimensional universe, as well as microscopic and irregular parameters such as volume, number, length and surface area. For structures such as cones or cylinders, volume and surface area can be easily calculated by applying known formulas. However, if a structure has irregular geometrical features, then complex processes are inevitability required. Currently, stereological methods are among the techniques suggested to estimate the metric properties of irregular sutures. It is easy, efficient and practical to apply some of these methods, such as volume estimation using the Cavalieri method, both in vivo and in vitro. However, determination of the surface area of complex and irregularly-shaped objects, especially objects in living organisms, is very difficult and not practical in terms of sampling procedure. Stereological principles for estimating surface area consist of either isotropic uniform random sampling (IURS) or VURS procedures [4].

The VURS procedure described by others and in our study is both difficult to understand and not practical to apply, particularly in in vivo situations, despite the fact that it is an efficient and useful approach to estimate the surface area of interesting objects. The most important disadvantage is the increased workload in the processing of the tissue due to the embedment and re-embedment [12]. This burden may be tolerated in macroscopic or perhaps microscopic studies that are conducted in vitro, but in radiological studies, to obtain and analyze VUR is not practical for a typical radiology unit. In our study, we found that approximately 540 sections, 5-mm thick, were required for the VURS procedure.

We estimated brain surface area from MR images that were obtained according to the VURS procedure as described in Materials and Methods. Directly vertical sections were obtained perpendicular to a fixed horizontal plane at angles of 0°–180°. We determined that there is no difference in the estimation of surface area or volume between VURS sections and directly vertical sections using an exhaustive series of a test object. We found no difference between surface area estimates using VURS sections or directly vertical sections in our empirical study. This result is consistent with a previous study that was carried out by Robert N, et al. (2000) [9]. In this study, cerebral hemispheres were sampled with 12 exhaustive series of vertical sections at 15° intervals about a fixed vertical axis [9] and surface area estimations were done with cycloid test lines [4]. Our study is similar to the study of Robert N, et al. (2000) with respect to the use of directly vertical sections at different angels to estimate surface area, but we also tried to obtain MR sections for estimating the surface area according to a vertical uniform random sampling procedure in order to compare with two approaches.

Figure 5.

Figure 5.

Surface area and volume values estimated in the study.

Table 5.

An example of total surface area and CE of a brain section in our study (angels of 60)

Section Number Number of Intersection (G) A
GXG
B
GXGi
C
GXGİ+1
1 13 169 299 325
2 23 529 575 690
3 25 625 750 725
4 30 900 870 1080
5 29 841 1044 1102
6 36 1296 1368 1656
7 38 1444 1748 1482
8 46 2116 1794 1656
9 39 1521 1404 1755
10 36 1296 1620 1584
11 45 2025 1980 1260
12 44 1936 1232 1408
13 28 784 896 952
14 32 1024 1088 1344
15 34 1156 1428 1496
16 42 1764 1848 1932
17 44 1936 2024 1540
18 46 2116 1610 1702
19 35 1225 1295 1120
20 37 1369 1184 1184
21 32 1024 1024 1312
22 32 1024 1312 1120
23 41 1681 1435 1394
24 35 1225 1190 1085
25 34 1156 1054 1156
26 31 961 1054 620
27 34 1156 680 748
28 20 400 440 420
29 22 484 462 308
30 21 441 294 126
31 14 196 84 0
32 6 36 0 0
A B C
Total 1024 35856 35086 34282

Footnotes

Conflict of interest statement: The authors declare that they have no conflict of interest to the publication of this article.

References

  • 1.Ronan L, Doherty CP, Delanty N, et al. A reliable protocol for measurement of cerebral gyrification using stereology. Magn Reson Imaging. 2006;24:265–72. doi: 10.1016/j.mri.2005.10.033. [DOI] [PubMed] [Google Scholar]
  • 2.Gokhale AM, Evans RA, Mackes JL, et al. Design-based estimation of surface area in thick tissue sections of arbitrary orientation using virtual cycloids. J Microsc. 2004;216:25–31. doi: 10.1111/j.0022-2720.2004.01392.x. [DOI] [PubMed] [Google Scholar]
  • 3.Jørgen H, Gundersen G. Estimation of tubule or cylinder LV, SV, and VV on thick sections. J Microsc. 1979;117:333–45. doi: 10.1111/j.1365-2818.1979.tb04690.x. [DOI] [PubMed] [Google Scholar]
  • 4.Baddeley AJ, Gundersen HJ, Cruz-Orive LM. Estimation of surface area from vertical sections. J Microsc. 1986;142:259–76. doi: 10.1111/j.1365-2818.1986.tb04282.x. [DOI] [PubMed] [Google Scholar]
  • 5.Kubinova L, Janacek J. Estimating surface area by the isotropic fakir method from thick slices cut in an arbitrary direction. J Microsc. 1998;191:201–11. doi: 10.1046/j.1365-2818.1998.00356.x. [DOI] [PubMed] [Google Scholar]
  • 6.Mattfeldt T, Mall G. Estimation of surface and length of anisotropic capillaries. J Microsc. 1984;153:181–90. doi: 10.1111/j.1365-2818.1984.tb00518.x. [DOI] [PubMed] [Google Scholar]
  • 7.Nyengaard JR, Gundersen HJG. The isector: a simple and direct method for generating isotropic, uniform random sections from small specimens. J Microsc. 1992;1992;165:427–31. [Google Scholar]
  • 8.Ronan L, Doherty CP, Delanty N, et al. Quantitative MRI: a reliable protocol for measurement of cerebral gyrification using stereology. Magn Reson Imaging. 2006;24:265–72. doi: 10.1016/j.mri.2005.10.033. [DOI] [PubMed] [Google Scholar]
  • 9.Roberts N, Puddephat MJ, McNulty V. The benefit of stereology for quantitative radiology. Br J Radiol. 2000;73:679–97. doi: 10.1259/bjr.73.871.11089458. [DOI] [PubMed] [Google Scholar]
  • 10.Gundersen HJ, Jensen EB. The efficiency of systematic sampling in stereology and its prediction. J Microsc. 1987;147:229–63. doi: 10.1111/j.1365-2818.1987.tb02837.x. [DOI] [PubMed] [Google Scholar]
  • 11.Roberts N, Puddephat MJ, McNulty V. The benefit of stereology for quantitative radiology. Br J Radiol. 2000;73:679–97. doi: 10.1259/bjr.73.871.11089458. [DOI] [PubMed] [Google Scholar]
  • 12.Dorph-Petersen K. Stereological estimation using vertical sections in a complex tissue. J Microsc. 1999;195:79–86. doi: 10.1046/j.1365-2818.1999.00471.x. [DOI] [PubMed] [Google Scholar]

Articles from The Eurasian Journal of Medicine are provided here courtesy of Ataturk University School of Medicine