Abstract
The ability to steer and focus light inside scattering media has long been sought for a multitude of applications. To form optical foci inside scattering media, the only feasible strategy at present is to guide photons by using either implanted1 or virtual2–4 guide stars, which can be inconvenient and limits potential applications. Here, we report a scheme for focusing light inside scattering media by employing intrinsic dynamics as guide stars. By time-reversing the perturbed component of the scattered light adaptively, we show that it is possible to focus light to the origin of the perturbation. Using the approach, we demonstrate non-invasive dynamic light focusing onto moving targets and imaging of a time-variant object obscured by highly scattering media. Anticipated applications include imaging and photoablation of angiogenic vessels in tumours as well as other biomedical uses.
To focus light deep into scattering media such as biological tissues, conventional manipulation of its phase is infeasible due to random scattering. As the propagation distance increases, the number of unscattered photons decays exponentially and becomes negligible beyond one transport mean free path (lt′)5 ; therefore, control of light is limited to a superficial depth of lt′. Obviously, it is highly desirable to break through this optical diffusion limit.
One can tune the scattered light in phase to maximize the spatial6 or spatiotemporal7 energy density at a desired location. By means of iterative wavefront shaping6–8, a large number of spatial modes are controlled to focus through6, or into1,9,10, a scattering medium at the target location, where a guide star is placed to generate feedback. However, these methods work by sequentially probing the input modes, an approach which remains impractically slow when the controlled degrees of freedom are many. A faster approach is to time-reverse (by phase-conjugating monochromatic light11) the scattered photons from a guide star back to their origin. To this end, nonlinear nanoparticles12 and fluorescent beads13 have served as implanted guide stars, and focused ultrasound2–4,14 has functioned as a virtual one. However, physical implantation is invasive and inflexible, and the virtual alternative requires physical contact for acoustic coupling and low loss at a sufficiently high acoustic frequency; they are unfavourable or infeasible for many scattering media.
Here, we explore the feasibility and potential applications of a new technology, named time-reversed adapted-perturbation (TRAP) optical focusing, which offers a strategy for passively guiding light inside scattering media without invasive implantation or physical contact. It works by remotely probing the scattering medium and employing spontaneous motions or intrinsic permittivity variations of the target as the guide stars. Although our analysis centres on absorption, generalization to the full permittivity tensor is straightforward (see Supplementary Discussion). The TRAP process comprises two steps. In step 1, the scattered light field distributions E1 and E2, defined at a location exterior to the scattering region, are probed at instants t1 and t2 while the target absorption changes from μ(r, t1) to μ(r, t2), as depicted in Fig. 1a,b, and the rest of the medium stays unchanged. The process is written mathematically as , where denotes the field distribution on the target plane at instant ti, and T is a transmission matrix characterizing the medium8,9. Subtracting the above equations yields the field perturbation ΔE = E2 − E1 = TΔEt. Because E1 and E2 are recorded interferometrically at two instants, instability of the two arms of the interferometer can lead to an overall random phase offset. If the phase of E1 is adapted by minimizing the norm ||ΔE|| (see Supplementary Methods), ΔEt is null anywhere except at the target location r. In step 2, as shown in Fig. 1c, focusing on the target position is subsequently achieved when the phase-adapted perturbation ΔE is phase-conjugated: TTΔE* = (T†ΔE)* ≈ (ΔEt)*, where the superscripts “T” and “†” denote transpose and conjugate transpose, respectively, and T†T ≈ I (I is the identity matrix) is assumed14. In the special case of a moving target inside the scattering region, the perturbation satisfies δμ(r1)= −δμ(r2) ≠ 0, where δ denotes the change from t1 to t2. Under such circumstances, phase-conjugating ΔE focuses light simultaneously on the old and the new target locations r1 and r2 (see Supplementary Movie 1 for details).
To guarantee high energy gain, digital optical phase conjugation (DOPC)3,4 is employed in TRAP focusing. The focusing process is schematically shown in Fig. 1d, e, and explained in detail in Methods. Speckle-scale focusing between two optical diffusers is demonstrated by perturbing the medium using a target particle, as shown in Fig. 1f (the cross-sectional intensity distributions along y and x are shown in Fig. 1g, h, respectively), and a moving particle induces focusing at two points, as shown in Fig. 1i (see Supplementary Methods for details).
An attractive feature of TRAP focusing is the ability to dynamically focus light onto a moving target hidden inside a scattering medium. As the target moves, a remote sensor keeps taking snapshots of the scattered electromagnetic field Ei (index i denotes the current target location) and generating phase maps from , where E0 is obtained when the target is absent. Repetitively reading the newly updated phase map ensures focusing onto the target, given an adequately short time lag between phase conjugation and the latest snapshot. The concept is demonstrated in Fig. 2, where light focuses dynamically from an SLM onto a moving target inside a scattering medium (Fig. 2a). In the experiment shown in Fig. 2b, an absorptive airplane pattern, printed on a transparency, was continuously translated between two optical diffusers. Meanwhile, the intensity distribution on the target was projected onto a camera by a beamsplitter to monitor the TRAP focus in real time. The light distribution outside the scattering medium, as measured on the SLM surface, manifested a random speckle pattern (Fig. 2d), indicating complete loss of the wavefront information. In salient contrast, as shown in Fig. 2c, light was dynamically focused onto the moving target as if scattering were totally suppressed (see Supplementary Methods for the experimental details and Supplementary Movie 2 for the dynamic focusing process). The demonstration, in which the scattering medium is static or quasi-static, does not bear full resemblance to a real situation. In reality, if the scattering medium changes too fast, the focusing will fail because the subtraction can no longer completely cancel the background. Consequently, for TRAP focusing to adapt to medium changes, the electronic processing time and the light round trip time have to be shorter than the medium correlation time; the maximum working distance is ultimately defined by the light round trip time.
In deep tissue imaging, TRAP focusing can enhance the signal and contrast by redistributing and concentrating light on the targets, hence extending the imaging depth. For example, red blood cells (RBCs) are extensively employed as endogenous contrast agents. They provide important physiological information, such as metabolism15. At shallow (<1 mm) depths, light scattering by moving RBCs provides a contrast mechanism for mapping blood perfusion16; such motion contrast creates intrinsic guide stars for time-reversed deep focusing. At two instants t1 and t2, RBCs form two sets of spatial patterns within blood vessels. Si denotes a set of RBC positions at instant i (i = 1, 2). If Δt = |t1 − t2| is selected to be between τRBC and τtissue (the field decorrelation times associated with the RBC and tissue movements, respectively), TRAP focusing generates optical foci at both S1 and S2, and thus concentrates energy on the RBCs. The concept was demonstrated by the set-up shown in Fig. 3a, where a blood-filled translucent silicone tube (300 μm inner diameter) was buried between two pieces of ex vivo chicken breast tissue samples, each 2.5 mm thick (~ 2.5 lt′ 4, see Supplementary Methods for sample preparation). During the TRAP procedure, S1 and S2 were realized by flowing diluted bovine blood (see Supplementary Methods for sample preparation) in the tube. The comparative focal light intensity distributions shown in Fig. 3b, c demonstrate that TRAP focusing achieved significant energy enhancement at the target region. The enhancement factor, according to Fig. 3d, was approximately 300%, limited by experimental constraints (see Supplementary Methods). Furthermore, when the vessels formed a three-dimensional (3D) pattern, TRAP focusing faithfully shaped light onto the corresponding structure, as shown in Fig. 3e–g (see Supplementary Methods and Supplementary Movie 3 for a 3D visualization).
Compared to schemes employing ultrasonic tagging2–4, the major advantage of TRAP focusing is efficiency. Ultrasound fundamentally lacks specificity. For targeted light delivery (such as in photodynamic therapy), an image has to be acquired before the region of interest is determined. Moreover, the ultrasonic tagging approach concentrates light only at the ultrasonic beam, whereas TRAP focusing simultaneously enhances energy deposition onto the perturbed target in the entire field of view. Such a unique capability can be extremely useful in many applications, such as phototherapy of port wine stains and photoacoustic computed tomography of blood vessels15.
A time-varying object can also be optically imaged by TRAP focusing. In the experiment shown in Fig. 4a, an absorptive target (the number “4”) hidden between two optical diffusers was completely invisible externally. When the target moved into the scattering region being probed, its TRAP pattern copied and spatially overlapped itself. We employed the speckle scanning technique, originally invented by Bertolotti et al.17 and recently implemented in biological samples by Yang et al.18, to scan the TRAP pattern across the target laterally (in x and y) by stepping through different phase gradients on the SLM while the transmitted light was monitored by a camera located outside the scattering region. The autocorrelation of the object, shown in Fig. 4b, was assessed after mathematical manipulations (see Supplementary Methods), and the shape of the object was readily obtained by an iterative algorithm19, as depicted in Fig. 4c. In comparison to previous approaches based on the memory effect for imaging through or inside scattering media12,17, TRAP focusing images only the perturbed regions, a feature especially useful in observing dynamic targets hidden in a relatively static background. This scheme will find ready applications in imaging angiogenic vessels in tumours. A limitation of the speckle scanning mechanism is the decrease of the speckle correlation angle with the medium thickness. Because the scanning has to cover the entire target, the imaging field of view, as well as the maximum target size, is reduced at greater depths18.
TRAP focusing uses subtraction to convert the embedded novelties to guide stars. In the past, differentiation has been widely applied to novelty detection. Optical novelty filters were invented to image changing parts in a scene by temporarily unbalancing an interferometer or perturbing a two-beam coupling device comprising a slow photorefractive crystal20,21. Holographic interferometry reveals differential information of an object by reconstructing superimposed holograms22. Recently, digital subtraction was used to enhance laser speckle imaging23 and assist optical particle tracking24. A microwave imaging scheme was proposed for tracking moving targets in clutter by subtracting multistatic data matrices and performing subsequent time reversal25. Among these endeavours, TRAP focusing is the first demonstration of scattering compensation using visible light by integrating optical time reversal with novelty detection.
Apart from permittivity change and translational movement, rotation and tumbling of an object can equivalently exert perturbation and promote focusing. This can be understood by projecting the finite-sized object to a basis formed by the input modes, thus translating the movement of the object to the perturbation of the original projection. Under the same framework, multiple objects can be generalized as a spatially disconnected object and treated similarly. An alternative TRAP model is given in the Supplementary Discussion. The upper bound for the target size is ultimately limited by the focus peak to background ratio3,4, whereas the smallest size is determined by the signal to noise ratio (γ) of the detection system. To resolve a single spatial mode in the presence of M input modes, 2Nsγ2 ≫ M is required, where Ns is the number of holograms used for the phase map calculation, and M equals the space-bandwidth product on the target plane (see Supplementary Discussion).
TRAP focusing (and time reversal in general) is sensitive to medium displacement and decorrelation (see Supplementary Discussion), which suggests that the whole procedure (including phase map measurements, electronic processing, and phase conjugation) must be accomplished sufficiently fast to adapt to the dynamics of the scattering medium. The speed of the current system can be dramatically improved once faster SLMs and cameras are available. An amplitude-only holographic configuration can further speed up the process (see Supplementary Discussion). The energy enhancement ratio at the target locations can also be dramatically increased if more spatial modes are phase conjugated (enabled by large pixel count SLMs and cameras26). We performed light focusing and imaging between two scattering media, where open access to the “inside” of the combined scattering medium enables convenient validation. This arrangement is, in principle, equivalent to focusing into a scattering medium14.
We emphasize that TRAP focusing does not necessarily rely solely on endogenous contrast agents. Its capability could be further extended by introducing exogenous agents with controlled motions or absorptions, such as magnetomotive particles27, voltage-sensitive dyes28 and photo-switchable dyes and proteins29,30. By incorporating such labelling strategies, TRAP focusing could be made even more versatile and powerful.
In summary, the TRAP focusing technology is envisioned to have profound impacts in a wide range of applications where the scattering effect needs to be suppressed, including optical tracking and trapping, photoacoustic tomography, optogenetics, photothermal therapy, and photodynamic therapy. Other wave-related fields can also potentially benefit from the same concept.
Methods
Experimental set-up
The experimental set-up used to generate and acquire the experimental data is shown in Supplementary Fig. S1. The source used was a Q-switched frequency-doubled Nd:YAG laser (Elforlight Inc., UK) centred at 532 nm with pulse duration of 10 ns and coherence length of 7 mm. The repetition rate of the laser was tuneable between 50 Hz and 200 Hz, and the full pulse energy was 0.6 mJ. Before entering the Mach-Zehnder interferometer, the light beam was collimated to a diameter of 2 mm by a beam expander. The power injected into the system was adjustable via a half-wave plate (HWP) paired with a polarizing beamsplitter (PBS), and further attenuated through a neutral density filter. Light was split into a probe beam and a reference beam by another PBS, the ratio between the two beams was controlled by a HWP. The polarization of the reference beam was rotated by 90° before passing through an acousto-optic modulator (AOM) which up-shifted its frequency by δf. The reference beam was further expanded by an afocal lens pair to a diameter of 25 mm and spatially filtered by a pinhole. The probe beam entered a scattering cell composed of two optical diffusers (DG10-600, Thorlabs, USA) or two pieces of ex vivo chicken breast tissue. The reference beam was combined with the scattered light from the probe by a 50:50 beamsplitter (BS1). The path lengths of the reference and probe beams were balanced for strongest interference using two tuneable delay lines. The combined beams then entered the DOPC module. Inside the DOPC, the beams were retro-reflected by the surface of a phase-only SLM (vis-PLUTO, Holoeye, Germany). The beams were further reflected by a 90:10 (90% transmission) beamsplitter (BS2) to form a speckle pattern on an sCMOS camera (pco. Edge, PCO AG, Germany). The pixels of the camera and the SLM were digitally aligned with ≤1 (pixel) alignment error for optimal phase conjugation quality. Once the scattered fields were measured at two instants, a TRAP phase map was calculated and displayed on the SLM. In the hologram reading mode, the probe beam was blocked. The reference beam passed through BS1 and BS2 and impinged on the SLM. Reflection by the SLM generated the phase-conjugated beam, which was delivered to the scattering medium after passing through BS2 and BS1. The light intensity distribution on the focal plane inside the two scattering media was monitored either by replacing the target with a CMOS camera (Firefly MV, Point Grey Research, Canada), or by using a BS to reflect the focal pattern onto the camera.
TRAP phase map measurement
The frequency difference between the probe and reference beams was set by the AOM modulation frequency, which was δf = 50.0000125 MHz. The AOM was triggered by a function generator (DG4000, RIGOL Technologies, China) with a sinusoidal waveform at δf. A delay generator (DG645, Stanford Research Systems, USA), sharing a global time-base with the function generator, produced two channels of pulse sequences at fs = 50 Hz with a proper relative delay to externally trigger and synchronize the laser and the camera. The reference beam, when undersampled at fs by the camera, cycled through four phases—0, π/2, π, 3π/2—corresponding to four interferograms Pi (i = 1, 2, 3, 4). During the measurement, the SLM was blanked by displaying a constant phase map (phase value = 0). The complex amplitude of the field was obtained by E = (P1 − P3) + i(P2 − P4). After the two complex amplitudes were acquired, they were subtracted to get ΔE, and the TRAP phase map was calculated by Φ = −arg [Im (ΔE)/Re(ΔE)] (arg[·] denotes taking the argument).
For applications requiring higher measurement accuracy (e.g., the experiment shown in Fig. 1f–i, where the perturbation was weak), a different signal acquisition scheme was used. The AOM was driven at δf = 50.0000001 MHz, and the delay generator triggered the laser and the camera at 200 Hz and 4 Hz, respectively. The sampling frequency of fs = 4 Hz ensured a phase difference of π/2 between neighbouring frames. The exposure time of the camera was set to 51 ms, during which 10 laser shots were averaged to reduce the noise caused by laser shot-to-shot intensity fluctuations.
TRAP focusing based on DOPC
In the probing mode (Fig. 1d), the scattered electromagnetic field distribution on a phase-only spatial light modulator (SLM) was measured via digital phase-shifting holography. The virtual difference field ΔE was synthesized by subtracting the fields acquired before and after the perturbation and then optimizing the phase offset. A phase map Φ was then extracted from ΔE and subsequently conjugated to yield the TRAP phase map (−Φ). In the focusing mode (Fig. 1e), an intense planar reading beam was transformed into a time-reversed beam after reflecting off the SLM, and converged onto the target.
Supplementary Material
Acknowledgments
We thank Fengbo Zhou for assistance on the flow control system, Lidai Wang for discussion on the experimental design, Yong Zhou for assistance on the dye solution preparation, and James Ballard for editing the manuscript. This work was sponsored by National Institutes of Health grants DP1 EB016986 (NIH Director’s Pioneer Award) and R01 CA186567 (NIH Director’s Transformative Research Award).
Footnotes
Author contributions C.M. and L.V.W. initiated the project. C.M. and X.X. implemented the DOPC-based system. C.M., X.X. and Y.L. designed and ran the experiments. C.M. wrote the codes for the experiments and simulation, and processed the experimental results. L.V.W. provided overall supervision. All authors involved in writing the manuscript.
Reprints and permissions information is available at www.nature.com/reprints.
The authors declare no competing financial interests.
References
- 1.Vellekoop IM, van Putten EG, Lagendijk A, Mosk AP. Demixing light paths inside disordered metamaterials. Opt Express. 2008;16:67–80. doi: 10.1364/oe.16.000067. [DOI] [PubMed] [Google Scholar]
- 2.Xu X, Liu H, Wang LV. Time-reversed ultrasonically encoded optical focusing into scattering media. Nature Photon. 2011;5:154–157. doi: 10.1038/nphoton.2010.306. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Si K, Fiolka R, Cui M. Fluorescence imaging beyond the ballistic regime by ultrasound-pulse-guided digital phase conjugation. Nature Photon. 2012;6:657–661. doi: 10.1038/nphoton.2012.205. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Wang YM, Judkewitz B, DiMarzio CA, Yang C. Deep-tissue focal fluorescence imaging with digitally time-reversed ultrasound-encoded light. Nat Commun. 2012;3:928. doi: 10.1038/ncomms1925. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Ntziachristos V. Going deeper than microscopy: the optical imaging frontier in biology. Nat Methods. 2010;7:603–614. doi: 10.1038/nmeth.1483. [DOI] [PubMed] [Google Scholar]
- 6.Vellekoop IM, Mosk AP. Focusing coherent light through opaque strongly scattering media. Opt Lett. 2007;32:2309–2311. doi: 10.1364/ol.32.002309. [DOI] [PubMed] [Google Scholar]
- 7.Katz O, Small E, Bromberg Y, Silberberg Y. Focusing and compression of ultrashort pulses through scattering media. Nature Photon. 2011;5:372–377. [Google Scholar]
- 8.Popoff S, Lerosey G, Fink M, Boccara AC, Gigan S. Image transmission through an opaque material. Nat Commun. 2010;1:81. doi: 10.1038/ncomms1078. [DOI] [PubMed] [Google Scholar]
- 9.Chaigne T, et al. Controlling light in scattering media non-invasively using the photoacoustic transmission matrix. Nature Photon. 2014;8:58–64. [Google Scholar]
- 10.Tay JW, Lai P, Suzuki Y, Wang LV. Ultrasonically encoded wavefront shaping for focusing into random media. Sci Rep. 2014;4:3918. doi: 10.1038/srep03918. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Yaqoob Z, Psaltis D, Feld MS, Yang C. Optical phase conjugation for turbidity suppression in biological samples. Nature Photon. 2008;2:110–115. doi: 10.1038/nphoton.2007.297. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Hsieh CL, Pu Y, Grange R, Laporte G, Psaltis D. Imaging through turbid layers by scanning the phase conjugated second harmonic radiation from a nanoparticle. Opt Express. 2010;18:20723–20731. doi: 10.1364/OE.18.020723. [DOI] [PubMed] [Google Scholar]
- 13.Vellekoop IM, Cui M, Changhuei Y. Digital optical phase conjugation of fluorescence in turbid tissue. Appl Phys Lett. 2012;101:081108. doi: 10.1063/1.4745775. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Judkewitz B, Wang YM, Horstmeyer R, Mathy A, Yang C. Speckle-scale focusing in the diffusive regime with time reversal of variance-encoded light (TROVE) Nature Photon. 2013;7:300–305. doi: 10.1038/nphoton.2013.31. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Wang LV, Hu S. Photoacoustic Tomography: In Vivo Imaging from Organelles to Organs. Science. 2012;335:1458–1462. doi: 10.1126/science.1216210. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Briers D, et al. Laser speckle contrast imaging: theoretical and practical limitations. J Biomed Opt. 2013;18:066018. doi: 10.1117/1.JBO.18.6.066018. [DOI] [PubMed] [Google Scholar]
- 17.Bertolotti J, et al. Non-invasive imaging through opaque scattering layers. Nature. 2012;491:232–234. doi: 10.1038/nature11578. [DOI] [PubMed] [Google Scholar]
- 18.Yang X, Pu Y, Psaltis D. Imaging blood cells through scattering biological tissue using speckle scanning microscopy. Opt Express. 2014;22:3405–3413. doi: 10.1364/OE.22.003405. [DOI] [PubMed] [Google Scholar]
- 19.Fienup JR. Reconstruction of an object from the modulus of its Fourier transform. Opt Lett. 1978;3:27–29. doi: 10.1364/ol.3.000027. [DOI] [PubMed] [Google Scholar]
- 20.Anderson DZ, Feinberg J, Lininger DM. Optical tracking novelty filter. Opt Lett. 1987;12:123–125. doi: 10.1364/ol.12.000123. [DOI] [PubMed] [Google Scholar]
- 21.Cudney R, Pierce R, Feinberg J. The transient detection microscope. Nature. 1988;332:424–426. [Google Scholar]
- 22.Brooks RE, Heflinger LO, Wuerker RF. Pulsed laser holograms. IEEE J Quantum Electron. 1966;2:275–279. [Google Scholar]
- 23.Liu R, Qin J, Wang RK. Motion-contrast laser speckle imaging of microcirculation within tissue beds in vivo. J Biomed Opt. 2013;18:060508. doi: 10.1117/1.JBO.18.6.060508. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Miccio L, et al. Particle tracking by full-field complex wavefront subtraction in digital holography microscopy. Lab Chip. 2014;14:1129–1134. doi: 10.1039/c3lc51104a. [DOI] [PubMed] [Google Scholar]
- 25.Fouda AE, Teixeira FL. Imaging and tracking of targets in clutter using differential time reversal techniques. Wave Random Complex. 2012;22:66–108. [Google Scholar]
- 26.Brady DJ, et al. Multiscale gigapixel photography. Nature. 2012;486:386–389. doi: 10.1038/nature11150. [DOI] [PubMed] [Google Scholar]
- 27.Jin Y, Jia C, Huang SW, O’Donnell M, Gao X. Multifunctional nanoparticles as coupled contrast agents. Nat Commun. 2010;1:41. doi: 10.1038/ncomms1042. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Peterka DS, Takahashi H, Yuste R. Imaging Voltage in Neurons. Neuron. 2011;69:9–21. doi: 10.1016/j.neuron.2010.12.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Rust MJ, Bates M, Zhuang X. Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM) Nat Methods. 2006;3:793–796. doi: 10.1038/nmeth929. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Patterson GH, Lippincott-Schwartz J. A Photoactivatable GFP for Selective Photolabeling of Proteins and Cells. Science. 2002;297:1873–1877. doi: 10.1126/science.1074952. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.