Abstract
Background
We have investigated the behaviour of a newly characterised population of haemarthrosis fluid-derived human mesenchymal stem cells (HF-hMSCs) with titanium (Ti) surfaces.
Methods
HF-hMSCs were seeded onto round cannulated interference (RCI; Smith and Nephew) screws or control Ti discs and cultured under pro-osteogenic conditions.
Results
Electron microscopy showed the attachment and spreading of HF-hMSCs across both Ti surfaces during the early stages of osteogenic culture; however, cells were exclusively localised to the basal regions within the vertex of the Ti screws. In the later stages of culture, an osteoid matrix was deposited on the Ti surfaces with progressive culture expansion and matrix deposition up the sides and the top of the Ti Screws. Quantification of cellular content revealed a significantly higher number of cells within the Ti screw cultures; however, there was no difference in the cellular health. Conversely, alizarin red staining used as both a qualitative and quantitative measure of matrix calcification was significantly increased in Ti disc cultures compared to those of Ti screws.
Conclusions
Our results suggest that the gross topography of the metal implant is able to create microenvironment niches that have an influence on cellular behaviour. These results have implications for the design of advanced tissue engineering strategies that seek to use cellular material to enhance biological remodelling and healing following tissue reconstruction.
Keywords: Titanium screws, Tissue engineering, Mesenchymal stem cells, Biocompatibility
Background
The use of inert material implants has provided the mainstay of dental, maxillofacial and orthopaedic reconstructive surgeries for decades [1]. Titanium (Ti) is one of the most common metals chosen for the manufacture of these medical devices with its chemistry providing high specific strength, a low Young’s modulus of elasticity that reduces the impact of peri-implant bone resorption, a high capacity for connecting to bone and soft tissues and the formation of a titanium oxide surface layer that supports biocompatibility and resistance to corrosion [1-5]. Because of these properties, Ti is often regarded as a more advantageous implant material, particularly for bone engineering, when compared to other metals such as cobalt, nickel, chromium and their respective alloys [2-7].
In recent years biomedical research has sought to develop more advanced tissue engineering strategies that augment the clinical outcomes of reconstructive surgeries, typically through stimulation of the biological tissue response to healing [1,8]. These approaches, mainly within the development stage at present, will often take the form of a cellular component (e.g. stem cells, progenitor cells or moderately expanded, mature, functional cells) combined with a biodegradable scaffold component that can provide a physical support for the cells as well as control physiologic behaviours such as differentiation (e.g. poly(lactic-co-glycolic acid) (PLGA); or poly-ε-caprolactone (PCL)) [9,10].
As a clinical exemplar of this evolution in surgical technologies, the focus of our research is the attachment of soft ligament tissue to bone and in particular the reconstruction of anterior cruciate ligament (ACL) following traumatic rupture. In this procedure, a Ti metal screw is used to fix pseudo-ligament tissue (typically taken from the hamstring tendon) within juxta-endosteal bony tunnels drilled at the anatomical anchor sites of the native ACL [11,12]. Whilst the screw is able to confer resistance to moderate biomechanical loading, the slow rate of biological tissue remodelling that ultimately leads to the osseous integration of the soft tissue graft can delay healing for up to 12 months post-surgery [13,14]. Revision surgery as a result of graft failure occurs within approximately 20% of cases and the prolonged period of joint destabilisation risks further meniscal and chondral damage in the short term as well as increasing the incidence of chronic degenerative joint diseases such as osteoarthritis [15,16].
We are seeking to develop a tissue engineering strategy to be used as an adjunct to conventional ACL reconstruction to improve the biological response post-surgery by enhancing and accelerating the osseous integration of the graft tissue. In previous work we have identified a novel population of osteogenic human mesenchymal stem cells derived from haemarthrosis fluid, the intra-articular bleed that is aspirated from the joint space during the acute phase of injury [17,18]. An investigation of the performance of these cells (termed heamarthrosis fluid-derived human mesenchymal stem cell (HF-hMSCs)) with a biomaterial capable of facilitating cell delivery and retention at the site of surgery has demonstrated the attachment, spreading and osteogenic differentiation on microparticles manufactured from PLGA [19].
The aim of this study is to investigate the behaviour of HF-hMSCs in response to titanium screws that are used to fix the soft tissue graft during standard ACL reconstruction. Here we report our initial findings comparing the attachment, proliferation and matrix mineralisation potential of HF-hMSCs in response to Ti discs and Ti RCI (Smith and Nephew) screws.
Materials and methods
Measurements of Ti surfaces
Ti discs and Ti screws
Ti discs (Grade 5, Ti6Al4V) were prepared by cutting 1-cm diameter rods to a length of 0.5 cm with a diamond saw. RCI Smith and Nephew screws (Grade 5, Ti6Al4V) were prepared by cutting the head and tapered end from each screw and sectioning lengthways using a diamond saw [20,21].
Roughness measurement
All of the roughness measurements were conducted using a stylus profilometer (Mitutoyo Surftest SV-2000 Mitutoyo, Halifax, UK) with dedicated analysis software (Surfpak- SV V1.600). A 5-μm radius diamond cone stylus tip was used to analyse the surface held at 90° to the surface with a contact force of 4 mN and a maximum height range of 800 μm. To measure roughness, a representative disc and screw specimen were selected. For the disc specimen, five randomly selected line scans were measured, with an evaluation length of 0.4 mm (5 sampling lengths of 0.08 mm). For the screw specimen, to measure the roughness in between the rakes, the specimen was held at 90° to the direction of travel of the profilometer, so that the stylus could sample the surface without making contact with a rake. A profile was measured between five successive rakes with an evaluation length of 0.4 mm (5 sampling lengths of 0.08 mm) used. All profiles were Gaussian filtered and baseline curvature was removed using the automatic software routine within the control software. As an estimate of roughness (Ra), the number average roughness was used.
Calculation of surface areas of Ti surfaces
The surface area of Ti discs exposed to cells was constant for all of the discs used within the study and was calculated as the surface area of a cylinder minus the area of the base:
where Γd = the exposed surface area of the disc; r = the radius of the disc, 0.5 cm; h = the height of disc = 0.5 cm.
Using a diamond saw, the head and tapered end of each Ti RCI screw was removed to give a constant thread section that was sectioned lengthways to allow for stable placement inside each well of the cell culture cluster plate. The surface area of the Ti screw exposed to the cells was calculated using the equation derived by Rammer and Zelinka [22]:
where Γs = the exposed surface area of the screw; Γc is the core surface area; h is length of the screw threaded section, ρ is the distance between adjacent thread crests, rt is the thread radius, rc is the core radius and tw is the thread width at the core diameter.
Cell culture
Acquisition of cellular material and derivation of human mesenchymal stem cell lines from haemarthrosis fluid
This study was carried out with full approval from Newcastle and North Tyneside 2 Research Ethics Committee and Newcastle upon Tyne Hospitals NHS Foundation Trust R&D. HF was aspirated from consented patients presenting at a clinic with acute knee injury (N = 3 patient samples were used; 33-year-old male, 54-year-old female, 64-year-old male).
Human mesenchymal stem cells (HF-hMSCs) were derived as previously described [17-19]. Mononuclear cells were isolated by Ficoll® gradient centrifugation (700 × g, 20 min), collected by centrifugation (90,000 × g, 3 min) and seeded into T-75 culture flasks in MSC medium (alpha minimum essential medium (αMEM), 10% (v/v) foetal bovine serum (FBS), 5 ng/ml fibroblast growth factor-2 (FGF2)). Non-adherent cells were removed from culture 3 days post-seeding, and fresh MSC medium was added. HF-hMSCs were passaged upon confluence at a ratio of 1:3 and used in experiments at passage 2.
Osteogenic differentiation of haemarthrosis fluid-derived mesenchymal stem cells
Ti discs or Ti screws were polished, autoclaved twice and placed in individual wells of a 12-well cell culture cluster plate. HF-hMSCs were seeded in 1-ml volumes in MSC medium at a cell density of 2.5 × 104 cells/cm2 Ti surface. Twenty-four hours post-seeding, the Ti discs and screws were transferred using aseptic technique into new wells of a fresh cell culture cluster plate, and the culture medium was replaced with osteogenic medium (αMEM, 10% (v/v) FBS, 20 ng/ml bone morphogenetic protein-2 (BMP2)) [19].
Cell culture analysis
Scanning electron microscopy
Ti disc and Ti screw samples were rinsed with PBS and fixed with 2% (w/v) glutaraldehyde overnight at 4°C. Samples were then dehydrated through a graded series of ethanol (25% (v/v), 50% (v/v), 75% (v/v), 1 × 30 each; 100% (v/v) 2 × 1 h each before being mounted onto carbon tabs and sputter coated with 15 nm of gold. Microscopy was performed using a Cambridge Stereoscan 240 scanning electron microscope.
Measurement of cell content within cultures
The amount of deoxyribonucleic acid (DNA) within Ti disc and Ti screw cultures was measured as a means of quantifying the cellular content of the cultures. Ti discs and Ti screws were transferred to empty wells of the 24-well cell cluster plate and rinsed twice with Dulbecco’s phosphate-buffered saline (DPBS). Cell lysate was prepared using 200-μl volumes of lysis buffer (0.5% Triton-X100 in DPBS) which was repeatedly rinsed over the surfaces using a pipette before overnight incubation at 4°C to allow complete penetration of the detergent and solubilisation of the biological material. The total amount of DNA in cultures was measured using the Quant-iT™ PicoGreen® dsDNA kit calibrated with known concentrations of λ double-stranded DNA as previously described [18]. Fluorescence from samples was measured at excitation: 484 nm/emission: 538 nm using a Fluoroskan I plate reader (MTX Lab Systems, Inc., Vienna, Virginia, USA). DNA was measured 24 h post-seeding and at days 7, 14, 21 and 28. Data is presented as N = 3 biological replicate with each biological replicate taken as the average of three technical replicates.
Cell viability
Ti discs and Ti screws were transferred to empty wells of the 24-well cell culture cluster plate before a 4-h culture in a 500-μl volume of alamarBlue® (stock alamarBlue® reagent diluted by 1:10 in osteogenic medium; as previously described [18]. Equivalent reactions of Ti discs and Ti screws without cells were assembled in parallel to serve as a negative control. Medium samples (100-μl volumes) were transferred in triplicate into a 96-well plate, and the fluorescence read at excitation 544 nm/emission 585 nm using a Fluoroskan I plate reader. The results were normalised to the amount of DNA per square centimetre of the surface area. Cell viability was measured 24 h post-seeding and at days 7, 14, 21 and 28. Data is presented as N = 3 biological replicates with each biological replicate taken as the average of three technical replicates.
Mineralised matrix deposition
Ti discs and Ti screws were transferred to empty wells of the 24-well cell cluster plate before a 2-h incubation in a 500-μl volume of alizarin red (2% (w/v) alizarin red in ddH2O; pH 4.2). Ti discs and Ti screws were rinsed extensively with DPBS until the DPBS runoff was clear. Matrix was solubilised by incubating the Ti discs and Ti screws overnight in 200-μl volumes of lysis buffer (0.5% Triton-X100 in DPBS) at 4°C to allow complete penetration of the detergent and solubilisation of the biological material. Equivalent staining reactions of Ti discs and Ti screws without cells were assembled in parallel to serve as a negative control. Lysate samples (50-μl volumes) were transferred in triplicate into a 96-well plate and the absorbance read at A492 using a Multiscan Ascent plate reader (MTX Lab Systems Inc.). Mineralised matrix deposition was measured 24 h post-seeding and at days 7, 14, 21 and 28. Data is presented as N = 3 biological replicate with each biological replicate taken as the average of three technical replicates.
Statistical analysis
Statistical analyses were performed using the SPSS Statistics 19 work package (IBM). Data sets were evaluated using the Kolmogorov-Smirnov test to determine distribution. Data sets that were normally distributed were analysed by parametric Student t-test. The non-parametric equivalent Kruskal-Wallis H test was used for data that was not normally distributed.
Results
HF-hMSCs were seeded onto Ti discs and Ti screws and cultured in osteogenic medium for up to 28 days. Electron microscopy analysis showed attachment and spreading of HF-hMSCs to Ti discs at day 1 with progressive expansion of the cell population across the surface of the disc (Figure 1A–B”). From day 14 of culture individual cells could not be discerned as electron micrographs revealed the progressive deposition of matrix (Figure 1C–E”). Whilst HF-hMSCs were also seen to attach and spread along the surface of the Ti screws, these cells were at first localised to the core surface at the base of the screw pitch (Figure 1F–G”). During osteogenic culture, the proliferation and expansion of the cell population was shown to be restricted exclusively to this basal region of the screw (day 14 of culture; Figure 1H–H”) before outgrowth up the sides of the screw pitch observed at day 21. By day 28 of osteogenic culture, the basal, side and top surfaces of the screw were covered by the cell population and evidence of deposited matrix was observed (Figure 1J–J”).
Analysis of the roughness profiles for the disc and screw specimen revealed that the general form of the surfaces was similar. However, the roughness data revealed that the disc was significantly rougher than the screw (t-test, disc mean (SD) Ra 0.10 (0.02), screw mean (SD) Ra 0.07 (0.01), P = 0.0007) (Figure 2).
Quantification of the cell content of Ti disc and Ti screw cultures was performed by quantification of DNA content during osteogenic culture and is presented as fold change in amount of DNA from day 1 per square centimetre of the surface area. Figure 3A shows a modest increase in DNA content on Ti discs with an approximate doubling of the cell population after 21 days of osteogenic culture. By day 28, the cell population had doubled again reflecting a fourfold increase in DNA content from day 1 of culture, representative of two rounds of cell division. The DNA content of osteogenic cultures on Ti screws was comparable with those of Ti discs at days 7 and 14; however, there was an increase in the amount of DNA between Ti screw and Ti disc cultures at day 21 (increase of 1.7 times; though not statistically significant) and at day 28 (increase of 2.6 times; P < 0.05). Overall there was a tenfold increase in the amount of DNA on Ti screws cultured over 28 days, representative of 3.125 cell divisions.
Because of the significant increase in cellular content on Ti screw cultures, a comparison of cellular vitality (cellular health) between osteogenic cell cultures on Ti discs and Ti screws was performed at day 28. Results are presented as measured fluorescence of alamarBlue® normalised to the amount of DNA per square centimetre of surface area and showed that there is no significant difference in cell vitality between the two culture surfaces (Figure 3B). This would indicate that the increase in cell number observed was a result of a positive increase in cell number (i.e. greater cell proliferation) rather than a loss of cells within the Ti disc cultures.
With evidence from the electron micrographs of the matrix on the surfaces of the titanium materials, we investigated the deposition of the mineralised matrix using alizarin red staining (Figure 4). Osteogenic cell cultures on Ti discs were negative of alizarin red staining at days 1 and 7. At day 14 of culture, modest alizarin red staining was observed and this was seen to become more intense as the osteogenic culture progressed to day 28 (Figure 4A–E). Osteogenic cultures on Ti screws were also negative for alizarin staining at days 1, 7 and 14; some alizarin red staining was evident at day 21 and this was intensified at day 28. Quantification of alizarin red staining was performed by measuring the absorbance of solubilised matrix (A492) normalised to the amount of DNA per square centimetre of the surface area and presented as fold increase from day 1 (Figure 5). Osteogenic cultures on Ti discs showed an increase in measured absorbance at day 21 (increase of 2.5 times; not statistically significant) and day 28 (increase of 9 times; P < 0.05). An increase in absorbance was also recorded for osteogenic cultures on Ti screws; however, after 28 days of osteogenic culture, this was only 30% of that recorded for those on Ti discs (P < 0.05).
Discussion
Ti is frequently considered as the metal of choice for the fabrication of implants used in reconstructive surgeries because of its properties of biocompatibility and the low propensity to cause hypersensitivity. Further modification to the chemistry of the metal is often sought however as a means of enhancing the desirable characteristics required in its intended use. For instance, Ti used in the manufacture of screws for attaching bone to bone or soft tissue to bone can be mixed with other metals for example copper, nickel, cobalt or chronium to form an alloy with increased shear strength and the ability to withstand higher biomechanical loads [23]. Similarly, coating the surface layer has been shown to enhance the osteoconductive properties of the metal (e.g. strontium-incorporated Ti oxide, magnesium, calcium phosphate), improving graft integration within the host tissue [24-29].
Recent clinical examples have demonstrated how the poor choice of material used in the manufacture of medical devices can lead to adverse effects on the patient [30-32]. This has highlighted the need for greater understanding of the biological interactions that take place when developing materials to be used in advanced surgical technologies, particularly in order to meet the requirements of what most likely will be a tighter regulatory framework [30-32]. We are investigating a cellular approach to enhancing soft tissue graft integration with bone using patient-derived HF-hMSCs and in this study carried out a preliminary investigation of these cells in response to a standard, Ti interference screw which is increasingly used clinically for ACL repair particularly when undertaking revision surgeries [33,34]. Previous reports have demonstrated the in vitro attachment of MSCs to Ti surfaces, and this is confirmed by our electron micrograph data [24,35]. Of particular interest was the pattern of cell attachment on the Ti screw where culture expansion was seen to be restricted in the early stages to the base of the screw. Whilst the cells would have most likely settled at the screw base upon initial seeding of the HF-hMSC culture, there was a clear segregation between the base and the side of the screw, and it was only in the later stages of culture that cell expansion and matrix deposition was observed on the inner sides and the top of the screw.
Consistent with our previous findings of HF-hMSCs cultured on the surfaces of PLGA microparticles, cell culture expansion (measured by DNA content) was initially slow for both Ti discs and Ti screws [19]. This phenomenon has also been reported by Wall et al. [35] investigating the interaction of bone marrow-derived hMSCS with Ti surfaces. In this study, it was proposed that the Ti surface was selective for a particular population of cells within a heterogeneous mix of MSCs and these cells underwent a lag phase prior to becoming established on the Ti surface. This is certainly possible; it is known for instance that the tissue from which MSCs are derived can influence MSC behaviour on Ti surfaces. MSCs originating from ligamentous tissues having a greater attachment to smooth rather than rough surfaces compared to osteoblastic cells, which preferentially adhere to rough surfaces [35-37]. Within an in vitro study such as ours however, it may be assumed that the starting hMSC population has become relatively homogeneous through the process of derivation and culture expansion. We would therefore suggest an alternative theory for exploration in that the hMSCs require this lag phase in order to regulate the expression of different receptor proteins (e.g. integrins, cell surface proteoglycans) and extracellular matrix proteins (e.g. fibronectin, collagens) that allows for their adaptation to a new culture substrate; the influence of integrin regulation on osteogenic differentiation of hMSCs has previously been reported [38]. We did observe significant differences in the behaviour of cells cultured on control Ti discs and the Ti screws with greater cell content and less alizarin red-positive matrix recorded for the latter cultures. This finding may relate to the Ti screw population having a reduced differentiation response compared to the Ti disc cultures. For instance, the basal region of the screw may establish a microenvironment that influences HF-hMSCs. An example of this might be differences in oxygen tension; we have previously shown that oxygen tension influences the proliferation and differentiation of HF-hMSCs [18]. Alternatively there could be an increased concentration of paracrine factors that regulate differentiation. Previously, Uchida et al. [39] used a murine fracture model to demonstrate in vivo bone engraftment and showed that, whilst ossification occurs around the Ti screw, healing was different to that observed within other regions of graft attachment. The authors of this study concluded that ossification was directed by different MSC populations originating from the bone marrow that had been penetrated by the Ti screw; however, there may be contributing influences brought by the microenvironment of the screw.
In conclusion, our study has demonstrated that compatibility of HF-hMSCs with Ti screws may facilitate the retention of the HF-hMSCs at the site of surgery. The behaviour of the cells may be influenced by the shape of the implant, and this could create a complex biological environment that influences the behaviour of the HF-hMSCs.
Acknowledgements
We wish to acknowledge the technical support of Dr Marcia Clark. Funding for this research was provided by a fellowship awarded to Dr Rachel Oldershaw, and we are also grateful for the financial support of the University of Liverpool and the University of Liverpool Wellcome Trust ISSF.
Abbreviations
- ACL
anterior cruciate ligament
- αMEM
alpha minimum essential medium
- BMP2
bone morphogenetic protein-2
- DPBS
Dulbecco’s phosphate-buffered saline
- FBS
foetal bovine serum
- FGF2
fibroblast growth factor-2
- HF
haemarthrosis fluid
- HF-hMSC
heamarthrosis fluid-derived human mesenchymal stem cell
- hMSC
human mesenchymal stem cell
- PCL
poly-ε-caprolactone
- PLGA
poly(lactic-co-glycolic acid)
- RCI
round cannulated interference
- Ti
titanium
Footnotes
Matthew J German, and Charles Osei-Bempong, are equal contributors.
Competing interests
The authors declare that they have no competing interest.
Authors’ contributions
MG, CO-B, CK, DD and RO were responsible for generating data. RO and DD were responsible for concept and design and the writing and final approval of the manuscript. All authors read and approved the final manuscript.
Contributor Information
Matthew J German, Email: matthew.german@ncl.ac.uk.
Charles Osei-Bempong, Email: charles.osei-bempong@ncl.ac.uk.
Callie A Knuth, Email: callieanknuth@gmail.com.
David J Deehan, Email: david.deehan@nuth.nhs.uk.
Rachel A Oldershaw, Email: lrao1@liverpool.ac.uk.
References
- 1.Holzapfel BM, Reichert JC, Schantz JT, Gbureck U, Rackwitz L, Nöth U, Jakob F, Rudert M, Groll J, Hutmacher DW. How smart do biomaterials need to be? A translational science and clinical point of view. Adv Drug Deliv Rev. 2013;65:581–603. doi: 10.1016/j.addr.2012.07.009. [DOI] [PubMed] [Google Scholar]
- 2.Sumner DR, Turner TM, Igloria R, Urban RM, Galante JO. Functional adaptation and ingrowth of bone vary as a function of hip implant stiffness. J Biomech. 1998;31:909–917. doi: 10.1016/S0021-9290(98)00096-7. [DOI] [PubMed] [Google Scholar]
- 3.Geetha M, Singh AK, Asokamani A, Gogia AK. Ti based biomaterials, the ultimate choice for orthopaedic implants — a review. Prog Mater Sci. 2009;54:397–425. doi: 10.1016/j.pmatsci.2008.06.004. [DOI] [Google Scholar]
- 4.Steinemann SG. Titanium—the material of choice? Periodontol. 1998;17:7–21. doi: 10.1111/j.1600-0757.1998.tb00119.x. [DOI] [PubMed] [Google Scholar]
- 5.Eisenbarth E, Velten D, Muller M, Thull R, Breme J. Biocompatibility of beta-stabilizing elements of titanium alloys. Biomaterials. 2004;25:5705–5713. doi: 10.1016/j.biomaterials.2004.01.021. [DOI] [PubMed] [Google Scholar]
- 6.McGregor DB, Baan RA, Partensky C, Rice JM, Wilbourn JD. Evaluation of the carcinogenic risks to humans associated with surgical implants and other foreign bodies — a report of an IARC Monographs Programme Meeting. International Agency for Research on Cancer. Eur J Cancer. 2000;36:307–313. doi: 10.1016/S0959-8049(99)00312-3. [DOI] [PubMed] [Google Scholar]
- 7.Wapner KL. Implications of metallic corrosion in total knee arthroplasty. Clin Orthop Relat Res. 1991;271:12–20. [PubMed] [Google Scholar]
- 8.Amini AR, Laurencin CT, Nukavarapu SP. Bone tissue engineering: recent advances and challenges. Crit Rev Biomed Eng. 2012;5:363–408. doi: 10.1615/CritRevBiomedEng.v40.i5.10. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Pashuck ET, Stevens MM. Designing regenerative biomaterial therapies for the clinic. Sci Transl Med. 2012;4:160sr4. doi: 10.1126/scitranslmed.3002717. [DOI] [PubMed] [Google Scholar]
- 10.Armentano I, Fortunati E, Mattioli S, Rescignano N, Kenny JM. Biodegradable composite scaffolds: a strategy to modulate stem cell behaviour. Recent Pat Drug Deliv Formul. 2013;7:9–17. doi: 10.2174/187221113804805874. [DOI] [PubMed] [Google Scholar]
- 11.Iorio R, Di Sanzo V, Vadalà A, Conteduca J, Mazza D, Redler A, Bolle G, Conteduca F, Ferretti A. ACL reconstruction with hamstrings: how different technique and fixation devices influence bone tunnel enlargement. Eur Rev Med Pharmacol Sci. 2013;17:2956–2961. [PubMed] [Google Scholar]
- 12.Halewood C, Hirschmann MT, Newman S, Hleihil J, Chaimski G, Amis AA. The fixation strength of a novel ACL soft-tissue graft fixation device compared with conventional interference screws: a biomechanical study in vitro. Knee Surg Sports Traumatol Arthrosc. 2011;19:559–567. doi: 10.1007/s00167-010-1255-5. [DOI] [PubMed] [Google Scholar]
- 13.Hsu SL, Wang CJ. Graft failure versus graft fixation in ACL reconstruction: histological and immunohistochemical studies in rabbits. Arch Orthop Trauma Surg. 2013;133:1197–1202. doi: 10.1007/s00402-013-1790-x. [DOI] [PubMed] [Google Scholar]
- 14.Woo SL, Niyibizi C, Matyas J, Kavalkovich K, Weaver-Green C, Fox RJ. Medial collateral knee ligament healing. Combined medial collateral and anterior cruciate ligament injuries studied in rabbits. Acta Orthop Scand. 1997;68:142–148. doi: 10.3109/17453679709003997. [DOI] [PubMed] [Google Scholar]
- 15.Chalmers PN, Mall NA, Moric M, Sherman SL, Paletta GP, Cole BJ, Bach BR., Jr Does ACL reconstruction alter natural history? A systematic literature review of long-term outcomes. J Bone Joint Surg Am. 2014;96:292–300. doi: 10.2106/JBJS.L.01713. [DOI] [PubMed] [Google Scholar]
- 16.Kiapour AM, Murray MM. Basic science of anterior cruciate ligament injury and repair. Bone Joint Res. 2014;3:20–31. doi: 10.1302/2046-3758.32.2000241. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Deehan DJ, Dowen DJ, Sprowson AP, Ferguson LC, Prathalingam NS, Isaacs JD, Birch MA, Oldershaw RA. Differential release of heterogeneous human mesenchymal stem cell populations from haemarthrotic traumatic knee injury. Am J Stem Cell Res. 2012;1:1–8. [Google Scholar]
- 18.Knuth CA, Clark ME, Meeson AP, Khan SK, Dowen DJ, Deehan DJ, Oldershaw RA. Low oxygen tension is critical for the culture of human mesenchymal stem cells with strong osteogenic potential from haemarthrosis fluid. Stem Cell Rev. 2013;9:599–608. doi: 10.1007/s12015-013-9446-3. [DOI] [PubMed] [Google Scholar]
- 19.Rogers CM, Deehan DJ, Knuth CA, Rose FR, Shakesheff KM, Oldershaw RA. Biocompatibility and enhanced osteogenic differentiation of human mesenchymal stem cells in response to surface engineered poly(d, l-lactic-co-glycolic acid) microparticles. J Biomed Mater Res A. 2014;102:3872–3882. doi: 10.1002/jbm.a.35063. [DOI] [PubMed] [Google Scholar]
- 20.Diomidis N, Mischler S, Nore NS, Roy M. Tribo-electrochemical characterization of metallic biomaterials for total joint replacement. Acta Biomater. 2012;8:852–859. doi: 10.1016/j.actbio.2011.09.034. [DOI] [PubMed] [Google Scholar]
- 21.Palmquist A, Lindberg F, Emanuelsson L, Brånemark R, Engqvist H, Thomsen P. Morphological studies on machined implants of commercially pure titanium and titanium alloy (Ti6Al4V) in the rabbit. J Biomed Mater Res B Appl Biomater. 2009;91B:309–319. doi: 10.1002/jbm.b.31404. [DOI] [PubMed] [Google Scholar]
- 22.Rammer DR, Zelinka SL. Analytical determination of the surface area of a threaded fastener. J Test Eval. 2009;36:1–9. [Google Scholar]
- 23.Okulov IV, Pauly S, Kühn U, Gargarella P, Marr T, Freudenberger J, Schultz L, Scharnweber J, Oertel CG, Skrotzki W, Eckert J. Effect of microstructure on the mechanical properties of as-cast Ti-Nb-Al-Cu-Ni alloys for biomedical application. Mater Sci Eng C Mater Biol Appl. 2013;33:4795–4801. doi: 10.1016/j.msec.2013.07.042. [DOI] [PubMed] [Google Scholar]
- 24.Park JW, Kim YJ, Jang JH, Suh JY. Surface characteristics and primary bone marrow stromal cell response of a nanostructured strontium-containing oxide layer produced on a microrough titanium surface. J Biomed Mater Res A. 2012;100:1477–1487. doi: 10.1002/jbm.a.34085. [DOI] [PubMed] [Google Scholar]
- 25.Park JW, Ko HJ, Jang JH, Kang H, Suh JY. Increased new bone formation with a surface magnesium-incorporated deproteinized porcine bone substitute in rabbit calvarial defects. J Biomed Mater Res A. 2012;100:834–840. doi: 10.1002/jbm.a.34017. [DOI] [PubMed] [Google Scholar]
- 26.Ibasco S, Tamimi F, Meszaros R, Nihouannen DL, Vengallatore S, Harvey E, Barralet JE. Magnesium-sputtered titanium for the formation of bioactive coatings. Acta Biomater. 2009;5:2338–2347. doi: 10.1016/j.actbio.2009.03.006. [DOI] [PubMed] [Google Scholar]
- 27.Xie Y, Zhai W, Chen L, Chang J, Zheng X, Ding D. Preparation and in vitro evaluation of plasma-sprayed Mg2SiO4 coating on titanium alloy. Acta Biomater. 2009;5:2331–2337. doi: 10.1016/j.actbio.2009.03.003. [DOI] [PubMed] [Google Scholar]
- 28.Li Y, Lee IS, Cui FZ, Choi SH. The biocompatibility of nanostructured calcium phosphate coated on micro-arc oxidized titanium. Biomaterials. 2008;29:2025–2032. doi: 10.1016/j.biomaterials.2008.01.009. [DOI] [PubMed] [Google Scholar]
- 29.Habibovic P, Li J, van der Valk CM, Meijer G, Layrolle P, van Blitterswijk CA, de Groot K. Biological performance of uncoated and octacalcium phosphate-coated Ti6Al4V. Biomaterials. 2005;26:23–36. doi: 10.1016/j.biomaterials.2004.02.026. [DOI] [PubMed] [Google Scholar]
- 30.Parvizi N, Woods K. Regulation of medicines and medical devices: contrasts and similarities. Clin Med. 2014;14:6–12. doi: 10.7861/clinmedicine.14-1-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Cox CL, Homlar KC, Carey JL, Spindler KP. CALAXO osteoconductive interference screw: the value of postmarket surveillance. J Surg Orthop Adv. 2010;19:121–124. [PMC free article] [PubMed] [Google Scholar]
- 32.Konan S, Haddad FS. The unpredictable material properties of bioabsorbable PLC interference screws and their adverse effects in ACL reconstruction surgery. Knee Surg Sports Traumatol Arthrosc. 2009;17:293–297. doi: 10.1007/s00167-008-0684-x. [DOI] [PubMed] [Google Scholar]
- 33.Barnett SL, Mayer RR, Gondusky JS, Choi L, Patel JJ, Gorab RS. Use of stepped porous titanium metaphyseal sleeves for tibial defects in revision total knee arthroplasty: short term results. J Arthroplasty. 2014;29:1219–1224. doi: 10.1016/j.arth.2013.12.026. [DOI] [PubMed] [Google Scholar]
- 34.Drogset JO, Grøntvedt T, Myhr G. Magnetic resonance imaging analysis of bioabsorbable interference screws used for fixation of bone-patellar tendon-bone autografts in endoscopic reconstruction of the anterior cruciate ligament. Am J Sports Med. 2006;34:1164–1169. doi: 10.1177/0363546505285384. [DOI] [PubMed] [Google Scholar]
- 35.Wall I, Donos N, Carlqvist K, Jones F, Brett P. Modified titanium surfaces promote accelerated osteogenic differentiation of mesenchymal stromal cells in vitro. Bone. 2009;45:17–26. doi: 10.1016/j.bone.2009.03.662. [DOI] [PubMed] [Google Scholar]
- 36.Grössner-Schreiber B, Herzog M, Hedderich J, Dück A, Hannig M, Griepentrog M. Focal adhesion contact formation by fibroblasts cultured on surface-modified dental implants: an in vitro study. Clin Oral Implants Res. 2006;17:736–745. doi: 10.1111/j.1600-0501.2006.01277.x. [DOI] [PubMed] [Google Scholar]
- 37.Mustafa K, Silva Lopez B, Hultenby K, Wennerberg A, Arvidson K. Attachment and proliferation of human oral fibroblasts to titanium surfaces blasted with TiO2 particles. A scanning electron microscopic and histomorphometric analysis. Clin Oral Implants Res. 1998;9:195–207. doi: 10.1034/j.1600-0501.1998.090307.x. [DOI] [PubMed] [Google Scholar]
- 38.Salasznyka RM, Kleesa RF, Williamsa WA, Boskeyb A, Plopper GE. Focal adhesion kinase signaling pathways regulate the osteogenic differentiation of human mesenchymal stem cells. Exp Cell Res. 2007;313:22–37. doi: 10.1016/j.yexcr.2006.09.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Uchida K, Ueno M, Naruse K, Urabe K, Onuma K, Sakai R, Itoman M, Takaso M. Bone marrow-engrafted cells after mice umbilical cord blood transplantation differentiate into osteoblastic cells in response to fracture and placement of titanium screws. Exp Anim. 2012;61:427–433. doi: 10.1538/expanim.61.427. [DOI] [PubMed] [Google Scholar]