Abstract
Background
Given the growing use of whole-exome sequencing (WES) for clinical diagnostics of complex human disorders, we evaluated coverage of clinically relevant cardiac genes on WES and factors influencing uniformity and depth of coverage of exonic regions.
Methods
Two hundred and thirteen human DNA samples were exome sequenced via Illumina HiSeq using different versions of the Agilent SureSelect capture kit. 50 cardiac genes were further analyzed including 31 genes from the American College of Medical Genetics (ACMG) list for reporting of incidental findings and 19 genes associated with congenital heart disease for which clinical testing is available. Gene coordinates were obtained from two databases, CCDS and Known Gene and compared. Read depth for each region was extracted from the exomes and used to assess capture variability between kits for individual genes, and for overall coverage. GC content, gene size, and inter-sample variability were also tested as potential contributors to variability in gene coverage.
Results
All versions of capture kits (designed based on Consensus coding sequence) included only 55% of known genomic regions for the cardiac genes. Although newer versions of each Agilent kit showed improvement in capture of CCDS regions to 99%, only 64% of Known Gene regions were captured even with newer capture kits. There was considerable variability in coverage of the cardiac genes. 10 of the 50 genes including 6 on the ACMG list had less than the optimal coverage of 30X. Within each gene, only 32 of the 50 genes had the majority of their bases covered at an interquartile range ≥30X. Heterogeneity in gene coverage was modestly associated with gene size and significantly associated with GC content.
Conclusions
Despite improvement in overall coverage across the exome with newer capture kit versions and higher sequencing depths, only 50% of known genomic regions of clinical cardiac genes are targeted and individual gene coverage is non-uniform. This may contribute to a bias with greater attribution of disease causation to mutations in well-represented and well-covered genes. Improvements in WES technology are needed before widespread clinical application.
Electronic supplementary material
The online version of this article (doi:10.1186/s12920-014-0067-8) contains supplementary material, which is available to authorized users.
Keywords: Exome sequencing, Coverage, Congenital heart disease, Cardiac, Genomics
Background
Next generation sequencing (NGS) has changed the diagnostic landscape for complex human disorders. Sequencing costs, particularly for exome sequencing, have plummeted over the last decade [1,2] allowing for the rapid uptake of technology in both the research and clinical realms. NGS platforms capitalize on parallel processing to generate hundreds of megabases of sequence from a single run allowing for deep coverage of vast regions [3]. A greater understanding of the limitations and potential pitfalls of sequencing technology is essential before clinical uptake of this technology [4]. Whole exome sequencing (WES) represents one NGS platform that has been effective in the study of rare Mendelian diseases and has become widely popular as an efficient method of identifying genetic variants within an individual’s genes. Currently WES has two major limitations: lower accuracy in nucleotide calls compared with Sanger sequencing and the lack of uniform coverage of exonic regions. The considerably higher rate when compared to Sanger sequencing of both false-negative and false-positive calls, can be minimized by increasing the depth of sequencing [5]. However, variant identification in whole exome sequencing is still limited by the non-uniformity of overall coverage which in turn is determined by sequence capture and read depth. Previous studies report considerable variability in uniformity and depth of coverage across the exome including base-to-base and gene-to-gene coverage [6-9]. Although newer versions of capture kits are designed to target a greater number of bases, it is unclear if capture of exonic loci is uniform across genes. In 2013, the American College of Medical Genetics (ACMG) published recommendations for reporting of incidental findings in clinical exome sequencing. Since a large number of genes for cardiac disorders are included in the ACMG reporting list [10], we assessed targeted capture and coverage of clinically relevant cardiac genes with whole exome sequencing and investigated factors contributing to heterogeneity in coverage.
Methods
Whole exome sequencing and candidate gene selection
Participants from six centers in Ontario were recruited prospectively to the Heart Centre Biobank Registry at the Hospital for Sick Children in Toronto. Details of the Biobank Registry have been published previously [11]. All probands/parents/legal guardians provided informed consent and the study was approved by the local research ethics boards at all participating sites (Hospital for Sick Children, Hamilton Health Sciences Centre, London Health Sciences Centre, Kingston General Hospital, Children’s Hospital of Eastern Ontario, and Toronto General Hospital). Probands with congenital heart disease and affected and unaffected relatives who underwent whole exome sequencing were included. All sequencing was performed using Illumina HiSeq with sequence capture performed using 3 different versions of the Agilent SureSelect Human All Exon capture kit. Twenty individuals were sequenced using Agilent 44 MB Version 2 (V2), 94 individuals were sequenced using the 50 MB Version 3 (V3), and 93 individuals were sequenced using the 51 MB Version 4 kit (V4). Additionally, we analyzed 6 exomes that were sequenced using the 50 MB Version 5 kit (V5) provided by the Wellcome Trust Sanger Institute. All exomes were aligned to the human genome version 19 using Burrows-Wheeler Aligner [12] to generate BAM files, and variant calling was performed using the Genome Analysis Tool Kit (GATK) [13]. For the purpose of coverage analysis, 50 clinically relevant cardiac genes were selected. These included 31 genes associated with cardiac disorders derived from the ACMG list for reporting of incidental findings i.e. genes associated with congenital heart disease (CHD), cardiomyopathies, vascular and rhythm disorders [10], and 19 additional genes associated with CHD not on the ACMG reporting list for which sequencing-based clinical genetic testing is currently available (Table 1).
Table 1.
Phenotype | Associated genes | |
---|---|---|
American College of Medical Genetics | ▪ Hypertrophic cardiomyopathy | MYBPC3, MYH7, TNNT2, TNNI3, TPM1, MYL3, ACTC1, PRKAG2, GLA, MYL2, LMNA |
▪ Dilated cardiomyopathy | ||
▪ Catecholaminergic polymorphic ventricular tachycardia | RYR2 | |
▪ Arrhythmogenic right ventricular cardiomyopathy | PKP2, DSP, DSC2, TMEM43, DSG2 | |
▪ Romano–Ward long QT syndrome | KCNQ1, KCNH2, SCN5A | |
▪ Brugada syndrome | ||
▪ Familial hypercholesterolemia | LDLR, APOB, PCSK9 | |
▪ Ehlers–Danlos syndrome, vascular type | COL3A1 | |
▪ Marfan syndrome | FBN1, TGFBR1, TGFBR2, SMAD3, ACTA2, MYLK, MYH11 | |
▪ Loeys–Dietz syndromes | ||
▪ Familial thoracic aortic aneurysms and dissections | ||
CHD genes | ▪ Genes associated with congenital heart disease | BRAF, NOTCH1, CFC1, NRAS, CHD7, PTPN11, GATA4, RAF1, HRAS, SOS1, JAG1, TBX1, KRAS, TBX5, MAP2K1, ZIC3, ELN, NKX2-5, NF1 |
Gene list includes American College of Medical Genetics list for reporting of incidental findings (n = 31) and genes associated with congenital heart disease (CHD) for which clinical testing is available (n = 19). All genes are listed according symbol.to their HUGO Gene Nomenclature Committee (HGNC).
Exonic regions represented in reference datasets
Agilent capture kits are primarily designed to target genes based on the National Center for Biotechnology Information Consensus Coding Sequence (CCDS) dataset. The CCDS database [14] is built by consensus among four major collaborating partners: European Bioinformatics Institute, National Center for Biotechnology Information (NCBI), Wellcome Trust Sanger Institute, and the UCSC [15-17]. The University of California, Santa Cruz (UCSC) Known Gene dataset houses a larger database that encompasses not only all the CCDS transcripts but also any protein coding genes that are substantiated by a transcript in GenBank mRNA or NCBI RefSeq and have a UniProt protein. Alternative splicing isoforms are also included in Known Gene if they represent a UniProt protein and have a transcript [18]. We therefore compared how well each gene was represented in both datasets by first obtaining gene coordinates for all protein coding regions of every available transcript in BED format from the CCDS and the Known Gene databases using the UCSC table browser [19]. BEDTools [20] was then used to collapse coordinates to unique locations in order to avoid overlap and also ensure all CCDS coordinates were contained within the Known Gene coordinates. For each gene the exonic regions included within the CCDS database were represented as a percentage of the Known Gene superset for that gene.
Cardiac gene coverage
Coverage across the 50 cardiac genes was analyzed as a combination of sequence capture and read depth. The read depth at each nucleotide was extracted from each subject’s exome BAM file using SAMtools mpileup [21]. Subsequent data handling was performed with custom scripting using the Python programming language (v2.7.1) [22]. The read depth or coverage was the number of independent times a particular nucleotide is represented in a collection of raw sequences, and was expressed numerically as 1X, 2X, 30X, etc. [23]. The read depth in every captured location was averaged across the samples sequenced for each capture kit. This produced an average capture per coordinate within both the CCDS and Known Gene datasets for each kit that was used in subsequent analyses.
Gene size and GC content
Gene size was calculated as the sum of unique bases of each candidate cardiac gene from the CCDS dataset. GC content was analyzed using BEDTools’ nuc function, along with UCSC’s human genome version 19 FASTA file, to output counts for each of the four nucleotides in a given region.
Statistical analysis
The proportion of bases in Known Gene regions captured by different versions of CCDS-based capture kits was compared. The comparison was performed across the entire targeted region as well as a gene by gene comparison to identify which genes had the highest discordance between databases. Actual coverage of the targeted region at a minimum read depth of 3X (the minimum depth required to identify a heterozygous mutation) and at an optimal read depth of 30X or higher (the minimum requirement for a confident genotype call) was then determined and influence of capture kit version and observed sequencing depth on coverage was analyzed. Uniformity of coverage was assessed across the candidate genes by calculating the median coverage of each gene as well as the variability in base to base coverage within each gene. Inter-sample variability was assessed for all bases within the CCDS targets by plotting the read depth confidence interval across all samples. Finally, the association between gene size and GC content on coverage of candidate cardiac genes was analyzed using linear regression. All statistical analysis was performed using the R statistical programming package (v3.0.1) [24].
Results
Study cohort
207 participants underwent whole exome sequencing between April 2012 and January 2013. 196 participants had a diagnosis of CHD and 17 had no structural heart defects. The average age at enrollment was 14.7 ± 11.7 years. 109 participants (53%) were male. Racial distribution included 85% Caucasians, 9% Asians, 1% African American, and 5% of mixed or unknown ethnicity. Six additional exome datasets were obtained from the Wellcome Trust Sanger Institute HapMap data with no information on disease status available.
Cardiac gene sequences represented in CCDS vs. known gene
The Agilent capture kits are designed to capture sequence data derived from the CCDS dataset. For the 50 cardiac genes, this amounts to a total of 166,271 bp of unique protein coding bases. For the Known Gene dataset, this amounts to 300,468 bp unique protein coding bases. Additional file 1: Table S1 shows the proportion of Known Gene regions that are also included in the CCDS. Overall only 55% of the regions within the Known Gene dataset for all genes were represented in the CCDS dataset. At individual gene level, this ranged from 10.1% (KRAS) to 96.8% (APOB).
Capture of cardiac genes by kit version
The extent to which each capture kit targeted the candidate gene sequences of the 50 cardiac genes was first assessed (Figure 1). For research studies, exomes are currently sequenced between 30X to 50X depth of coverage to confidently distinguish heterozygous or homozygous mutations from misaligned reads or artifact. However, to compare overall capture between various capture kits, regions covered at a read depth of at least 3X were included. At a read depth of 3X or higher, the Agilent V2 captured 92% of the CCDS cardiac gene region. This increased to 97% with Agilent V3, 98% with Agilent V4, and 99% with Agilent V5. While each newer kit version showed improved capture of CCDS regions, capture of the Known Gene regions remained low. The Agilent V2 captured only 55% of the Known Gene cardiac regions. Captured improved to 60% with V3, 64% with V4, and 63% with V5. The exonic regions within the CCDS versus Known Gene database targeted and captured for each gene are shown in Additional file 1: Table S1. Only 55-64% of the Known Gene regions were captured by the current CCDS-based capture kits. Therefore, although newer capture kit versions showed improvement in the amount of CCDS regions captured reaching up to 99%, the Known Gene capture only improved marginally up to 64% with the V5 kit showing no improvement over its predecessor V4.
Uniformity of coverage of cardiac genes
Since each capture kit was sequenced at a different intended depth, we used the exome dataset that had the highest observed average read depth for further analysis of uniformity of coverage across cardiac genes. The observed average read depth for Agilent V2 capture kit was 30.5X, for the Agilent V3 capture kit was 80X, for the Agilent V4 capture kit was 48X, and for the Agilent V5 capture kit was 63X (Figure 2). Therefore, given that the Agilent V3 capture kit had the highest overall observed read depth, this dataset (n = 94) was further analyzed to assess the uniformity of coverage of each of the 50 cardiac genes. Despite high read depths, Figure 3A shows the considerable variability in coverage between genes and within genes. Ten genes were covered at a median read depth of less than the optimal 30X. These included 2 genes associated with long QT syndrome (types 1, 2, and 3) and Brugada syndrome (KCNQ1, KCNH2), 3 genes associated with hypertrophic and dilated cardiomyopathy (LMNA, MYBPC3, TNNI3), 1 gene associated with familial hypercholesterolemia (PCSK9), and 4 genes associated with CHD (GATA4, NKX2-5, NOTCH1, TBX1). For comparison Figure 3B shows the same plot but for the Agilent V2 data that had the lowest observed average read depth of 30.5X. Here we see that 30 of the 50 genes had median read depth below 30X and only 5 genes had an IQR above 30X. Expressing gene coverage as a median read depth does not imply that all bases within that gene are covered at the same depth. A small number of highly covered bases may skew the average toward the higher end despite the majority of bases having low read depth. Therefore the inter-quartile range (IQR) for base-by-base coverage for each gene was measured. Only 32 of the 50 genes examined had the majority of their bases covered at an IQR ≥30X. To determine if there was inter-sample variability, the 95% confidence interval per captured CCDS base by each of the three capture kits across samples was calculated (Figure 4). Despite the use of different capture kits and different intended sequencing depths, the consistency in capture across exomes was maintained with very minimal inter-sample variability (over 85% of bases fell within ±5 reads, with the exception of the V5 capture kit data that only included 6 exomes and therefore 85% of bases fell within ±10 reads). Overall, these findings suggest that while higher sequencing depths improved average coverage across targeted genomic regions, the gene-by-gene and base-by-base coverage remained non-uniform.
Association of gene size and GC content with genomic coverage
The potential contribution of gene size and GC content to the gene-to-gene variability in coverage was evaluated. Gene size showed a significant but modest correlation with median coverage (r2 = 0.19; p = 1.46 × 10−3) and accounted for less than 20% of the variance in coverage of the cardiac genes. There was however a strong negative correlation between mean coverage and GC content as higher GC content was associated with lower median coverage per gene (Figure 5A). Figure 5A shows median coverage and GC content of each gene sorted with highest coverage on the left. Figure 5B shows the significant inverse relationship between GC content and median coverage (r2 = 0.55; p = 8.66 × 10−10). Figure 5C shows the significant difference in percent GC content of the 5 best-covered genes and the 5 worst-covered genes (p = 1.48 × 10−5). In fact, of the 50 cardiac genes, genes with highest coverage had a GC content of <50% while poorly covered genes had a GC content of >50%.
Discussion
The increasing use of next generation sequencing for research and clinical genetics and the move towards scanning the genome or exome not only for variation in targeted genes of relevance to the disease under study, but also for variant-detection in other disease-associated genes has intensified the focus on the technical accuracy and validity of the technology [10]. Coverage analysis of 50 clinically important cardiac genes using data from research based WES demonstrated considerable base-by-base and gene-by-gene variability in coverage within and across the candidate genes. Sources of variability included incomplete targeting of exonic regions, low capture efficiency, low sequencing depth, larger gene size and high GC content within the target region. Despite improvement in median coverage across the exome with newer capture kits and with higher sequencing depths, the coverage of individual genes was non-uniform. Overall, these results highlight the importance of assessing adequacy of coverage of target genes when analyzing whole exome data for disease genes and the need to improve current technology before whole exome sequencing can be widely deployed towards clinical cardiac diagnostics.
The first important finding was incomplete capture of clinically important cardiac genes with whole exome sequencing. Currently, exome sequencing capture kits are primarily designed to capture regions identified within the CCDS database. However, unlike the Known Gene database, the CCDS does not contain all possible transcripts, thereby restricting target regions to just over 50% of known genomic regions. Missing exonic nucleotides not captured with these kits may result in non-detection of variants in alternate isoforms. The difference in exonic region definition varies greatly at the gene level as shown in Additional file 1: Table S1 where the number of bases per gene for the 50 cardiac genes in the CCDS dataset can range from 10% to 96% of their size in the Known Gene dataset. Given that some known transcripts identified within the Known Gene dataset have yet to be approved in the CCDS dataset, there is a potential bias in gene discovery towards genes that are already well defined within the CCDS. Further increase in target regions is necessary to enhance more uniform and complete capture across the exome.
The most important metric of efficiency for a capture experiment is the proportion of targeted DNA inserts that are specifically hybridized and recovered from the capture. Our results showed that, for the 50 genes studied, minimum coverage (3X) was obtained to a high degree (92% to 98%) for all the capture kit versions within the CCDS. Higher depth of sequencing can improve coverage across difficult targets and as expected, the proportion of the genomic regions with high read depth was improved when intended sequencing depth was also higher with optimal coverage (30X) reached for 82.0% of the targets that were sequenced using the Agilent V3 kit that had an observed average depth of 80X. Despite overall improvement in coverage, there remained significant gene-to-gene variability in coverage. Ten of the 50 cardiac genes (including 6 on the ACMG list) had a median coverage that was less than optimal (<30X), increasing the risk of under-detection of true positives (Type II error). Thus a high intended depth of sequencing can improve the efficiency of capture but it increases costs and did not increase the number of genomic regions covered. Improving coverage will therefore require improvement in the capture technology and probe capture design to capture previously missing regions of the exome.
Gene-to-gene variability in coverage was not accounted for by inter-sample variability, which was consistently low across all 50 genes, and only modestly related to the size of the exonic regions examined for each gene. It did however correlate with GC content with lower coverage in regions that showed a high GC content. This limitation in sequencing regions with high GC content has been identified previously [6,25]. Targeted re-sequencing and modified sequencing techniques, such as oligonucleotide-selective sequencing, may provide a more efficient strategy to deal with GC rich genes [26]. Therefore, a preliminary screen for the amount GC content of candidate genes prior to sequencing is recommended.
In summary, these results highlight the importance of assessing adequacy of coverage of candidate or target genes in genomic analyses to avoid false negative results. When comparing cohorts sequenced using different capture kits or sequencing platforms, coverage analysis plays an even more significant role. Underreporting of variants due to lower coverage in one cohort can result in false ascertainment of enrichment of variants in the well covered cohort resulting in a Type II error. Accurate assessment of coverage between cohorts should also look beyond the commonly reported mean/median depth per base. This type of measure for overall coverage gives no indication of the uniformity of coverage across the gene. Base-by-base read depth comparison should be assessed to ensure cohorts are comparable at specific variant sites.
A limitation of our study is that we did not assess if structural variation, such as common and rare copy number variants (CNVs), contribute to the discrepancy in coverage when analyzing a small subset of genes especially in the presence of population specific CNVs. Another limitation is that we did not study the impact of coverage on variant detection sensitivity. However, several other studies have already evaluated variant detection sensitivity with exome data and identified numerous factors that influence variant detection sensitivity including coverage, quality of alignment and mapping, duplicates, strand bias, and type of algorithm used [5,27-29]. A recent study also found that a mean on-target read depth of 17-37X is required to identify 90% of heterozygous SNVs in the targeted regions, depending on the uniformity of read coverage [30]. Therefore strategies to enhance capture and coverage as well as the sensitivity in variant detection are needed.
Conclusions
In conclusion, non-uniformity of coverage is a limitation of exome sequencing and may introduce bias into gene and variant discovery. As the application of exome sequencing expands into the clinical domain, careful interpretation of findings in the context of coverage is essential. Improvements to sequencing capture technology to expand the targeted regions and advances in bioinformatic approaches to account for differential coverage are essential to improve clinical implementation. From a research perspective, care should be taken when assessing overall mutation burden or identifying casual variants or genes. There is a bias towards well-covered and easy to sequence genes and a risk of under-reporting of mutation burden in poorly covered genes.
Acknowledgements
The authors acknowledge the following individuals and organizations: SickKids Labatt Family Heart Centre Biobank Registry for access to DNA samples; Mina Safi, Alan Fung, and Steven Habbous for assistance with data acquisition. The work was supported by funding from the Heart and Stroke Foundation of Ontario Chair in Cardiovascular Sciences (S.M), Heart and Stroke Foundation of Canada Research Fellowship (A.K.M), Ontario Ministry of Research and Innovation International Strategic Opportunities Program (S.M), McLaughlin Centre Accelerator Grant in Genomic Medicine (S.M), SickKids Labatt Family Heart Centre Innovation Funds (D.M, L.D, S.M), the Roma and Marvin Auerback Endowment funds (S.M).
Abbreviations
- ACMG
American College of Medical Genetics
- CHD
Congenital heart disease
- CCDS
Consensus CDS
- CNV
Copy number variant
- NGS
Next generation sequencing
- WES
Whole exome sequencing.
Additional file
Footnotes
Competing interests
The authors declare that they have no competing interests.
Authors’ contributions
LCD, AKM, and SM were responsible for the overall design, conduct and writing of the study. Analysis and interpretation of genomic data was done by DM, LCD, and AKM. Sequencing and alignment for the 94 exomes using the Agilent 50 MB Version 3 cohort was done by SAT and MEH. All authors contributed to writing, reviewing, editing and approving the manuscript.
Contributor Information
Dorin Manase, Email: dorin.manase@sickkids.ca.
Lisa CA D’Alessandro, Email: lisac.dalessandro@sickkids.ca.
Ashok Kumar Manickaraj, Email: ashokkumar.manickaraj@sickkids.ca.
Saeed Al Turki, Email: sa9@sanger.ac.uk.
Matthew E Hurles, Email: meh@sanger.ac.uk.
Seema Mital, Email: seema.mital@sickkids.ca.
References
- 1.Dewey FE, Pan S, Wheeler MT, Quake SR, Ashley EA. DNA sequencing clinical applications of New DNA sequencing technologies. Circulation. 2012;125:931–944. doi: 10.1161/CIRCULATIONAHA.110.972828. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Majewski J, Schwartzentruber J, Lalonde E, Montpetit A, Jabado N. What can exome sequencing do for you? J Med Genet. 2011;48:580–589. doi: 10.1136/jmedgenet-2011-100223. [DOI] [PubMed] [Google Scholar]
- 3.Ng SB, Turner EH, Robertson PD, Flygare SD, Bigham AW, Lee C, Shaffer T, Wong M, Bhattacharjee A, Eichler EE. Targeted capture and massively parallel sequencing of 12 human exomes. Nature. 2009;461:272–276. doi: 10.1038/nature08250. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Dorn C, Grunert M, Sperling SR. Application of high-throughput sequencing for studying genomic variations in congenital heart disease. Brief Funct Genomics. 2014;13:51–65. doi: 10.1093/bfgp/elt040. [DOI] [PubMed] [Google Scholar]
- 5.Strom SP, Lee H, Das K, Vilain E, Nelson SF, Grody WW, Deignan JL. Assessing the necessity of confirmatory testing for exome-sequencing results in a clinical molecular diagnostic laboratory. Genet Med. 2014;16:510–515. doi: 10.1038/gim.2013.183. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Parla JS, Iossifov I, Grabill I, Spector MS, Kramer M, McCombie WR. A comparative analysis of exome capture. Genome Biol. 2011;12:R97. doi: 10.1186/gb-2011-12-9-r97. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Dias C, Sincan M, Cherukuri PF, Rupps R, Huang Y, Briemberg H, Selby K, Mullikin JC, Markello TC, Adams DR. An analysis of exome sequencing for diagnostic testing of the genes associated with muscle disease and spastic paraplegia. Hum Mutat. 2012;33:614–626. doi: 10.1002/humu.22032. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Dewey FE, Grove ME, Pan C, Goldstein BA, Bernstein JA, Chaib H, Merker JD, Goldfeder RL, Enns GM, David SP. Clinical interpretation and implications of whole-genome sequencing. JAMA. 2014;311:1035–1045. doi: 10.1001/jama.2014.1717. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Sulonen A-M, Ellonen P, Almusa H, Lepistö M, Eldfors S, Hannula S, Miettinen T, Tyynismaa H, Salo P, Heckman C. Comparison of solution-based exome capture methods for next generation sequencing. Genome Biol. 2011;12:R94. doi: 10.1186/gb-2011-12-9-r94. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Green RC, Berg JS, Grody WW, Kalia SS, Korf BR, Martin CL, McGuire AL, Nussbaum RL, O’Daniel JM, Ormond KE. ACMG recommendations for reporting of incidental findings in clinical exome and genome sequencing. Genet Med. 2013;15:565–574. doi: 10.1038/gim.2013.73. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Papaz T, Safi M, Manickaraj A-K, Ogaki C, Kyryliuk JB, Burrill L, Dodge C, Chant-Gambacort C, Walter L-L, Rosenberg H. Factors influencing participation in a population-based biorepository for childhood heart disease. Pediatrics. 2012;130:e1198–e1205. doi: 10.1542/peds.2012-0687. [DOI] [PubMed] [Google Scholar]
- 12.Li H, Durbin R. Fast and accurate short read alignment with Burrows–Wheeler transform. Bioinformatics. 2009;25:1754–1760. doi: 10.1093/bioinformatics/btp324. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.McKenna A, Hanna M, Banks E, Sivachenko A, Cibulskis K, Kernytsky A, Garimella K, Altshuler D, Gabriel S, Daly M. The genome analysis toolkit: a MapReduce framework for analyzing next-generation DNA sequencing data. Genome Res. 2010;20:1297–1303. doi: 10.1101/gr.107524.110. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Coffey AJ, Kokocinski F, Calafato MS, Scott CE, Palta P, Drury E, Joyce CJ, LeProust EM, Harrow J, Hunt S. The GENCODE exome: sequencing the complete human exome. Eur J Hum Genet. 2011;19:827–831. doi: 10.1038/ejhg.2011.28. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Pruitt KD, Harrow J, Harte RA, Wallin C, Diekhans M, Maglott DR, Searle S, Farrell CM, Loveland JE, Ruef BJ. The consensus coding sequence (CCDS) project: Identifying a common protein-coding gene set for the human and mouse genomes. Genome Res. 2009;19:1316–1323. doi: 10.1101/gr.080531.108. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Harte RA, Farrell CM, Loveland JE, Suner M-M, Wilming L, Aken B, Barrell D, Frankish A, Wallin C, Searle S. Tracking and coordinating an international curation effort for the CCDS project. Database. 2012;2012:bas008. doi: 10.1093/database/bas008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Farrell CM, O’Leary NA, Harte RA, Loveland JE, Wilming LG, Wallin C, Diekhans M, Barrell D, Searle SM, Aken B. Current status and new features of the consensus coding sequence database. Nucleic Acids Res. 2014;42:D865–D872. doi: 10.1093/nar/gkt1059. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Hsu F, Kent WJ, Clawson H, Kuhn RM, Diekhans M, Haussler D. The UCSC known genes. Bioinformatics. 2006;22:1036–1046. doi: 10.1093/bioinformatics/btl048. [DOI] [PubMed] [Google Scholar]
- 19.Karolchik D, Hinrichs AS, Furey TS, Roskin KM, Sugnet CW, Haussler D, Kent WJ. The UCSC table browser data retrieval tool. Nucleic Acids Res. 2004;32:D493–D496. doi: 10.1093/nar/gkh103. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Quinlan AR, Hall IM. BEDTools: a flexible suite of utilities for comparing genomic features. Bioinformatics. 2010;26:841–842. doi: 10.1093/bioinformatics/btq033. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Li H, Handsaker B, Wysoker A, Fennell T, Ruan J, Homer N, Marth G, Abecasis G, Durbin R. The sequence alignment/map format and SAMtools. Bioinformatics. 2009;25:2078–2079. doi: 10.1093/bioinformatics/btp352. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.VanRossum G, Drake FL. The Python Language Reference. Amsterdam, Netherlands: Python Software Foundation; 2010. [Google Scholar]
- 23.Sims D, Sudbery I, Ilott NE, Heger A, Ponting CP. Sequencing depth and coverage: key considerations in genomic analyses. Nat Rev Genet. 2014;15:121–132. doi: 10.1038/nrg3642. [DOI] [PubMed] [Google Scholar]
- 24.R Development Core Team: R: A language and environment for statistical computing. Vienna, Austria: R Foundation for Statistical Computing; 2012.
- 25.Wooderchak-Donahue WL, O’Fallon B, Furtado LV, Durtschi JD, Plant P, Ridge PG, Rope AF, Yetman AT, Bayrak-Toydemir P. A direct comparison of next generation sequencing enrichment methods using an aortopathy gene panel-clinical diagnostics perspective. BMC Med Genomics. 2012;5:50. doi: 10.1186/1755-8794-5-50. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Myllykangas S, Buenrostro JD, Natsoulis G, Bell JM, Ji HP. Efficient targeted resequencing of human germline and cancer genomes by oligonucleotide-selective sequencing. Nat Biotechnol. 2011;29:1024–1027. doi: 10.1038/nbt.1996. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Liu X, Han S, Wang Z, Gelernter J, Yang B-Z. Variant callers for next-generation sequencing data: a comparison study. PLoS One. 2013;8:e75619. doi: 10.1371/journal.pone.0075619. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Wang Q, Jia P, Li F, Chen H, Ji H, Hucks D, Dahlman KB, Pao W, Zhao Z. Detecting somatic point mutations in cancer genome sequencing data: a comparison of mutation callers. Genome Med. 2013;5:91. doi: 10.1186/gm495. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Rieber N, Zapatka M, Lasitschka B, Jones D, Northcott P, Hutter B, Jager N, Kool M, Taylor M, Lichter P, Pfister S, Wolf S, Brors B, Eils R. Coverage bias and sensitivity of variant calling for four whole-genome sequencing technologies. PLoS One. 2013;8:e66621. doi: 10.1371/journal.pone.0066621. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Meynert AM, Bicknell LS, Hurles ME, Jackson AP, Taylor MS. Quantifying single nucleotide variant detection sensitivity in exome sequencing. BMC Bioinformatics. 2013;14:195. doi: 10.1186/1471-2105-14-195. [DOI] [PMC free article] [PubMed] [Google Scholar]