Skip to main content
Plant Physiology logoLink to Plant Physiology
. 1981 Aug;68(2):506–508. doi: 10.1104/pp.68.2.506

Two Types of Ventilated Porometers Compared on Broadleaf and Coniferous Species 1,2

Jon D Johnson 1,3
PMCID: PMC427520  PMID: 16661946

Abstract

Two ventilated porometers (diffusion and steady-state) were compared on four broadleaf and five coniferous species. The diffusion porometer gave consistently lower conductance values for both types of species, reflecting a direct stomatal response to low chamber humidity. At high conductance values, the porometers produced a linear and nearly equal response, but the diffusion porometer was less sensitive at low conductance values. This was due to lower air flow (20% of the velocity in the steady-state porometer) and water vapor sorption (by its acrylic plastic chamber). The broadleaf species had less variation (R2 = 0.81) than did the coniferous species (R2 = 0.61), but, with the latter, there was better correspondence between the two porometers, possibly due to sampling technique. Conductance values were clustered by species.

Full text

PDF
506

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Kanemasu E. T., Thurtell G. W., Tanner C. B. Design calibration and field use of a stomatal diffusion porometer. Plant Physiol. 1969 Jun;44(6):881–885. doi: 10.1104/pp.44.6.881. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Turner N. C., Parlange J. Y. Analysis of operation and calibration of a ventilated diffusion porometer. Plant Physiol. 1970 Jul;46(1):175–177. doi: 10.1104/pp.46.1.175. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Plant Physiology are provided here courtesy of Oxford University Press

RESOURCES