Abstract
Introduction: The aim of this study was to evaluate and compare the in vitro effect of the Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) laser with different radiation distances and high-speed rotary treatment on the shear bond strength of flowable composite to enamel of human permanent posterior teeth.
Methods: freshly extracted human molar teeth with no caries or other surface defects were used in this study (n=45). The teeth were randomly divided into 3 groups. Group 1: treated with non-contact Er:YAG Laser and etched with Er:YAG laser, Group 2: treated with contact Er:YAG Laser and etched with Er:YAG laser, Group 3 (control): treated with diamond fissure bur and etched with acid phosphoric 37%. Then the adhesive was applied on the surafces of the teeth and polymerized using a curing light appliance. Resin cylinders were fabricated from flowable composite. Shear bond strength was tested at a crosshead speed of 0.5 mm/min.
Results: The amount of Shear Bond Strength (SBS) in the 3 treatment groups was not the same (P<0.05).The group in which enamel surfaces were treated with diamond fissure bur and etched with acid (conrtol group) had the highest mean shear bond strength (19.92±4.76) and the group in which the enamel surfaces were treated with contact Er:YAG laser and etched with Er:YAG laser had the lowest mean shear bond strength (10.89±2.89). Mann-whitney test with adjusted P-value detected significant difference in shear bond strength between the control group and the other 2 groups (P < 0.05).
Conclusion: It was concluded that both contact and non-contact Er:YAG laser treatment reduced shear bond strength of flowable resin composite to enamel in comparison with conventional treatment with high speed rotary. Different Er:YAG laser distance irradiations did not influence the shear bond strength of flowable composite to enamel.
Keywords: Er YAG lasers, flowable composite, enamel
Introduction
Dental caries are the most common infectious diseases in adult individuals, worldwide1. In recent years, there was some great progress in caries removal techniques towards non-invasive and conservative techniques, which are aimed to preserve the tooth structures. Michael Buonocore in 1955, laid the foundation of acid-etching and adhesive restorative systems. This caused a new approach in cavity preparations, and today, operative and pediatric dentistry aim to use fast and effective caries removal techniques with a minimum smear layer formation2, 3.
Despite all the progress made in dentistry, yet using carbide and diamond burs, is the most common caries removal technique in dental offices. Conventional high-speed rotary causes some disadvantages and discomforts for patients, such as: bone-conducted noise, tooth crack and fracture caused by hand-piece vibration and thermal damages to pulpal tissues. Erbium Lasers are the most practical alternative techniques for caries removal, which provide some advantages like no noise or vibration, no smear layer formation, decreased recurrent caries caused by increased resistance of cavity walls to acid, decreased tooth sensitivity caused by sealing dentin tubules and reduced need for use of local anesthesia4-8.
Erbium lasers family has been the ideal technique in pediatric dentistry because of their low depth of penetration in tissue, highly hydrophilic characteristic and lack of thermal damages. This family includes Erbium, Chromium doped Yttrium Scandium Gallium Garnet (Er-Cr: YSGG) and Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) with 2790 nm and 2940 nm wavelengths, respectively9,10. The high-speed rotary technique can be replaced by Er:YAG Laser, first developed by Zharikov et al.11 in 1975, which has a great potential for removing caries and hard tissues. Caries and hard tissues removal by laser, is done through the ablation process, in which most of the laser energy is absorbed by the water present in dental hard tissue, and then collagen and hydroxyapatite12,13.
Recently, a brand new resin composite with low viscosity has been produced, called flowable composite with some characteristics such as low viscosity, low modulus elasticity and easily applicable. There are not enough studies about this kind of composite, used to increase adhesion to hybrid composite or lased hard tissues14-19.
There are various studies evaluating the shear bond strength of laser-treated dentin,12, 20, 21, but there are not sufficient studies about the effect of laser on shear bond strength of enamel. Pelagalli et al.22 reported that Er:YAG laser was equal or better than high speed rotary in the tested procedures of caries removal, cavity preparation, and etching prior to acid etching. Dunn et al.23 and Martínez-Insua et al.24 reported a decrease in bond strength to Er:YAG laser-irrigated dental hard tissues.
According to our knowledge, the literature only contains a few studies about shear bond strength of flowable composite to laser-treated enamel25, therefore the aim of this study was to compare the shear bond strength of flowable composite to enamel, treated with contact or non-contact Er:YAG laser and conventional technique.
Methods
Freshly extracted human molar teeth with no carries or other surface defects were used in this study (n=45). Any remaining soft tissues were removed from the teeth surfaces using rotary brushes and dental scalers. The teeth were stored in 0.5 % chloramine-T solution for one week and then in normal saline solution and room temperature, up to the beginning of the experiment and were used within 6 months after the time of extraction.
The teeth were mounted horizontally, in blocks of self-polymerized acrylic resin (Acropars - Iran) in order to leave only buccal surfaces exposed. Then samples were randomly divided into 3 groups:
Group 1: treated with non-contact Er:YAG Laser and etching with Er:YAG laser
Group 2: treated with contact Er:YAG Laser and etching with Er:YAG laser
Group 3 (control): treated with diamond fissure bur and etching with acid phosphoric 37 %
In group 1, enamel surfaces of the teeth were treated with non-contact hand-piece, pulsed mode Er:YAG laser (DEKA, Italy) with air–water spray cooling (2940 nm, 500mj, 5 W, 10 Hz, 4 mm distance from the buccal surface, spot size 1 mm). The distance was standardized using an endodontic k-file attached to the tip of the hand-piece and the laser beam was perpendicular to the tooth surface26.
In group 2, enamel surfaces were treated with contact hand-piece Er:YAG laser (DEKA, Italy ) with air–water spray cooling (2940 nm, 5 W, 500 mj,10 Hz, with no distance from the buccal surface).
In group 3 or control, enamel surfaces were treated with diamond fissure bur no.1 in sweeping moves (4 moves) with high-speed rotary and air–water spray cooling.
In groups 1 and 2, the enamel surfaces were etched with Er:YAG laser (2940 nm, 5 w, 10 Hz, 50 mj ,4 mm distance from the buccal surface).
In group 3 (control), the samples were rinsed and dried, then the enamel surfaces were etched with acid phosphoric 37 % (Vivadent- Ivoclar, Germany) for 20 seconds and rinsed with water for 20 seconds and then dried completely for 10 seconds with air spray23.
Then in all groups, one layer of dental adhesive (Heliobond, Vivadent- Ivoclar, Germany) was applied on the etched enamel surfaces, dried with air spray for 5 seconds23 and then polymerized with curing light appliance (Coltolux, OH, US, 400 mW/cm2) for 10 seconds, according to the manufacturer’s instructions.
After what, plastic tubes with a diameter of 3 mm and a height of 3 mm were filled with flowable composite (Vivadent- Ivoclar, Germany) and was polymerized for 40 seconds (Coltolux, OH, US, 400 mW/cm²) according to the manufacturer’s instructions.
Samples were stored in distilled water at 37˚ C for 1 day, for final adaptations27.
Shear bond strength of samples was measured using Universal testing Machine (Zwick - Germany) at a crosshead speed of 0.5 mm/s and was calculated from the peak load at failure divided by the sample surface area.
The mean shear bond strength in mega pascals (MPa) was calculated for each group. The data obtained were analyzed using Kruskal-Wallis Test and Mann-whitney test with adjusted P-value for paired comparison between study groups.
Results
The mean amount of Shear Bond Strength (SBS) in groups one, two and three was 11.93±4.14, 10.89±2.89 and 19.92±4.76, respectively (Table 1 ),(P > 0.05). According to Kruskal-Wallis Test the highest mean rank belonged to control group (group 3) and the lowest mean rank belonged to group 2.
Table 1. The results of One-Sample Kolmogorov-Smirnov Test for SBS.
| Group | Mean±SD | P-value |
| Treated with non-contact Er:YAG Laser and etching with Er:YAG laser (group 1 ) | 11.93±4.14 | 0.992 |
| Treated with contact Er:YAG Laser and etching with Er:YAG laser ( group 2 ) | 10.89±2.89 | 0.980 |
| Treated with fissure bur and etching with acid ( group 3 ) | 19.92±4.76 | 0.990 |
According to the result of Mann-whitney test with adjusted P-value, there was a significant difference in shear bond strength between the control group and two other groups (groups 1 and 2) (P < 0.05) but there was no significant difference in shear bond strength between groups 1 and 2 (P > 0.05).
Discussion
In recent years, there was some great progress in dental materials, caries diagnosis and caries removal techniques towards non-invasive and conservative techniques, which are aimed to preserve the tooth structures20. In 1978, Simonsen28 introduced preventive resin Restorations (PRR) using small burs and minimal invasive preparation methods, including resin composite, adhesives and sealants. This was a successful preservative method indicated by further reports29. Today, with the introduction of resin composites with low viscosity and high resistance to wear (Flowable composites), this technique has turned to an easier method30,31.
Laser is recommended in order to increase the adhesion of resin composites to dental hard tissues. Also, it is recommended to use for etching tooth surfaces25. However using laser for these purposes is still controversial; some studies suggested the use of laser for preparing or etching dentin32-34, but some other studies reported that it is not an efficient method35-37. Among minimal invasive preparation techniques, Erbium lasers family is the most trustworthy one38.
Least thermal damage has been reported using this laser39. Because of more comfort, less working time, noise, pain and fear, the use of Er:YAG laser in pediatric dentistry has increased. The caries removal mechanism of Er:YAG laser is based on the absorption of laser energy by water molecules present in dental hard tissues. This leads to increased pressure in the radiation spot and micro explosions which cause dental hard tissue to eject as micro particles. This process is accomplished with minimal or no thermal damages38. Enamel tissue undergoes some structural changes during the Er:YAG laser ablation process such as no formation of smear layer, surface irregularities and enamel prisms exposure. These changes are supposed to increase the bond strength of resin composites40 but in fact, these micro porosities generated by laser ablation, do not have the same ideal pattern obtained by acid phosphoric application. Therefore this heterogeneous structure in lased enamel, affects the bond strength of resin composite24.
The result of restorative treatments could be predicted by evaluating the shear bond strength of resin composites applied with various techniques2,41. There are some studies evaluating the shear bond strength of resin composites to lased dentin,12, 20, 21, but there are not enough studies about the shear bond strength of flowable composite to lased enamel25. Therefore this study was aimed to evaluate and compare the shear bond strength of flowable composite to enamel treated with conventional method and Er:YAG laser.
Pelagalli et al.22 reported that Er:YAG laser was equal or better than the drill in the tested procedures of caries removal, cavity preparation, and etching prior to acid etching . Dunn et al.23 and Martínez-Insua et al.24 reported a decrease in bond strength to Er:YAG laser-irrigated dental hard tissues .
Yazici et al.25 reported that there are differences in shear bond strength of Self-adhesive flowable composite according to the dentin treatment technique and it is higher for silicon carbide abrasive group, but there are no such differences for conventional flowable composite. In the current study, we concluded that treatment technique could affect the shear bond strength of conventional Flowable composite too, and specimens treated by conventional method using high speed rotary had significantly higher shear bond strength than the ones treated with Er:YAG laser.
Lessa FC et al.42 in their study evaluated the influence of Er:YAG laser irradiation distance on the shear bond strength of an adhesive restorative system to primary enamel. They reported that different Er:YAG laser distance irradiations did not influence the shear bond strength of adhesive restorative system to enamel. Basaran et al.43 in their study reported that laser Irradiation distance influenced the shear bond strength of adhesion to enamel and the mean shear bond strength obtained with the Er:YAG laser at 1 and 2 mm distances groups and with the Er,Cr:YSGG laser at 1 mm distance group were comparable to the mean shear bond strength obtained with acid etching group. In the current study, the results were in accord with Lessa FC et al. study42 and we concluded that different Er:YAG laser distance irradiations could not influence the shear bond strength of flowable composite to enamel.
Previous studies indicated that the Er:YAG laser treatment associated with acid-etching can improve the bond strength of resin composite to enamel26, 44. Therefore, it is mandatory that new researches and studies indicate the efficiency of Er:YAG laser treatment previous to acid-etching.
Conclusion
According to Kruskal-Wallis Test, the highest mean rank belonged to control group (group 3) and the lowest mean rank belonged to group 2 and according to the result of Mann-whitney test with adjusted P-value, there was a significant difference in shear bond strength between the control group and two other groups (groups 1 and 2) (P < 0.05), but there was no significant difference in shear bond strength between groups 1 and 2 (P > 0.05).
Based on the results of this study and considering the limitations of in vitro studies, it can be concluded that:
- The specimens treated with conventional technique using a bur previous to acid-etching had higher shear bond strength than the ones treated with Er:YAG laser (contact or non-contact hand-piece).
- Different Er:YAG laser distance irradiations did not influence the shear bond strength of flowable composite to enamel.
Please cite this article as follows:
Parhami P, Pourhashemi SJ, Ghandehari M, Mighani G, Chiniforush N. Comparative Study of the Shear Bond Strength of Flowable Composite in Permanent Teeth Treated with Conventional Bur and Contact or Non-Contact Er:YAG Laser. J Lasers Med Sci 2014;5(3):140-5
References
- 1.Bagramian RA, Garcia-Godoy F, Volpe AR. The global increase in dental caries: a pending public crisis. Am J Dent. 2009;22:38. [PubMed] [Google Scholar]
- 2.Antunes LA, Pedro RL, Vieira AS, Maia LC. Effectiveness of high speed instrument air abrasion on different dental subtracts. Braz Oral Res. 2008;22:235–41. doi: 10.1590/s1806-83242008000300008. [DOI] [PubMed] [Google Scholar]
- 3.Buonocre MG. A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces. J Dent Res. 1995;34:849–53. doi: 10.1177/00220345550340060801. [DOI] [PubMed] [Google Scholar]
- 4.Keller U, Hibst R, Geurtsen W, Schlike R, Heidemann D, Klaiber B. et al. Erbium-YAG laser application in caries therapyEvaluation of patient perception and acceptance. J Dent. 1998;26(8):649–56. doi: 10.1016/s0300-5712(97)00036-5. [DOI] [PubMed] [Google Scholar]
- 5.Fornaini C, Riceputi D, Lupi-Pegurier L, Rocca JP. Patient responses to Er:YAG laser when used for conservative dentistry. Lasers Med Sci. 2012;27(6):1143–9. doi: 10.1007/s10103-011-1012-0. [DOI] [PubMed] [Google Scholar]
- 6.Bohari MR, Chunawalla YK, Ahmed BM. Clinical evaluation of caries removal in primary teeth using conventional, chemomechanical and laser technique: an in vivo study. J Contemp Dent Pract. 2012;13(1):40–7. doi: 10.5005/jp-journals-10024-1093. [DOI] [PubMed] [Google Scholar]
- 7.De Moor RJG, Delmé KIM. Laser assisted cavity preparation and adhesion to erbium-lased tooth structurePart 1. J Adhes Dent. 2010;11:427–38. doi: 10.3290/j.jad.a18136. [DOI] [PubMed] [Google Scholar]
- 8.Bader C, Krejci I. Indications and limitations of Er;YAG laser applications in dentistry. Am J Dent. 2006;19:178–86. [PubMed] [Google Scholar]
- 9.Hossain M, Nakamura Y, Yamada Y, Kimura Y, Matsumoto K, Matsumoto N. Effects of Er,Cr:YSGG laser irradiation in human enamel and dentin. J Clin Laser Med Surg. 1999;17:105–9. doi: 10.1089/clm.1999.17.155. [DOI] [PubMed] [Google Scholar]
- 10.Hibst R, Keller U, Steiner R. The effects of pulsed Er;YAG laser irradiation on dental tissue. Laser Med Surg. 1998;4:163–5. [Google Scholar]
- 11.Zharikov EV, Zhekvo VI, Kulesvskii LR, Murina TM, Osiko VV. Stimulated emission from Er3C ions in Yttrium aluminum garnet crystals at lZ294 mg. Soviet J Quantum Electron. 1975;4:1039–40. [Google Scholar]
- 12.Visuri SR, Gilbert JL, Wright DD, Wigdor HA, Walsh JT Jr. Shear strength of composite bonded to Er;YAG laser-prepared dentin. J Dent Res. 1996;75:599–605. doi: 10.1177/00220345960750011401. [DOI] [PubMed] [Google Scholar]
- 13. Kumazaki M. Removal of hard dental tissue (cavity preparation) with Er;YAG laser . In 6th international congress on lasers in dentistry. Proceedings 1998; Hawaii. 12-5.
- 14.Sirirungrojying S, Hayakawa T, Saito K, Meguro D, Nemoto K, Kasai K. Bonding durability between orthodontic brackets and human enamel treated with Megabond self-etching primer using 4-META/MMA –TBB resin cement. Dent Mater J. 2004;23:251–7. doi: 10.4012/dmj.23.251. [DOI] [PubMed] [Google Scholar]
- 15.Hayakawa T, Fukushima T, Nemoto K. Tensile bond strength of 4-META/MMA-TBB resin to ground bovine enamel using a self-etching primer. Dent Mater J. 2004;23:271–7. doi: 10.4012/dmj.23.271. [DOI] [PubMed] [Google Scholar]
- 16.Yokomichi R, Taira Y, Soeno K, Atsuta M. Influence of acid-base conditioning of the bond strength of five luting agents employing self-etching primer to enamel and dentin. Dent Mater J. 2005;24:232–7. doi: 10.4012/dmj.24.232. [DOI] [PubMed] [Google Scholar]
- 17.Cao L, Geerts S, Gueders A, Albert A, Seidel L, Carpentier J. Experimental comparison of cavity sealing ability of five dental adhesive systems after thermo-cycling. J Adhes Dent. 2003;5:139–44. [PubMed] [Google Scholar]
- 18.Atash R, Van den Abbeele. A Bond strengths of eight contemporary adhesives to enamel to dentin: An in vitro study on bovine primary teeth. Int J Paediatr Dent. 2005;15:264–3. doi: 10.1111/j.1365-263X.2005.00650.x. [DOI] [PubMed] [Google Scholar]
- 19.Nara Y, Nagakura Y, Ito Y, Suzuki T, Kizuki I, Kimishima T. et al. Tensile bond strength of all-in-one self-etch adhesive system to cervical abrasion lesion dentin. J Dent Res. 2003;81:B–55. [Google Scholar]
- 20.Sakakibara Y, Ishimaru K, Takamizu M. A study on bond Strength to dentin irradiated be Erbium:YAG laser. Jpn J Conservative Dent. 1998;41:207–19. [Google Scholar]
- 21.Armengol V, Jean A, Rohanizadeh R, Hamel H. Scanning Electron microscopic analysis of diseased and healthy dental hard tissues after Er:YAG laser irradiation: in vitro study. J Endod. 1999;25(8):543–6. doi: 10.1016/S0099-2399(99)80376-8. [DOI] [PubMed] [Google Scholar]
- 22.Pelagalli J, Gimble CB, Hansen RT, Swett A, Win II DN. Investigational study of the use of Er:YAG laser versus dental drill for caries removal and cavity preparation—phase 1. J Clin Laser Med Surg. 1997;15(3):109–15. doi: 10.1089/clm.1997.15.109. [DOI] [PubMed] [Google Scholar]
- 23.William J Dunn,, John T Davis, Anneke C. Bush. Shear bond strength and SEM evaluation of composite bonded to Er:YAG laser-prepared dentin and enamel. Dent Mater. 2005;21:616–24. doi: 10.1016/j.dental.2004.11.003. [DOI] [PubMed] [Google Scholar]
- 24.Martínez-Insua A, da Silva Dominguez L, Guitian Rivera F, Santana-Penin UA. Differences in bonding to acid-etched or Er:YAG-laser-treated enamel and dentin surfaces. J Prosthet Dent. 2000;84:280–8. doi: 10.1067/mpr.2000.108600. [DOI] [PubMed] [Google Scholar]
- 25.Yazici A, Agarwal I, Campillo-Funollet M, Munoz-Viveros C, AAntonson S, EAntonson D. et al. Effect of laser preparation on bond strength of a self-adhesive flowable resin. Lasers Med Sci. 2013;28:343–7. doi: 10.1007/s10103-012-1158-4. [DOI] [PubMed] [Google Scholar]
- 26.Jafari A, Shahabi S, Chiniforush N, Shariat A. Comparison of the Shear Bond Strength of Resin Modified Glass Ionomer to Enamel in Bur-Prepared or Lased Teeth (Er: YAG) J Dent (Tehran) 2013;10(2):119–23. [PMC free article] [PubMed] [Google Scholar]
- 27.Barcellos DC, Borges AB, Goncalves S, Pavanello MB, Souza AC, Gomes Torres C. Influence of Er;YAG laser on shear bond strength of self-etching adhesives to Bovine enamel : In vitro study. World J Dent 2. 011;2(1):11–5. [Google Scholar]
- 28.Simonsen RJ. Preventive resin restora- tions. Quintessence Int. 1978;9:69–76. [PubMed] [Google Scholar]
- 29. Simonsen RJ, Landy NA. Preventive resin restorations: fracture resistance and 7 year clinical results. J Dent Res 1984 ;( Special Issue) 63:175, abstract no. 39.
- 30.Moon PC, Tabassian Tabassian, Culbreath TE. Flow characteristics and film thickness flowable resin composites. Oper Dent. 2002;27:248–53. [PubMed] [Google Scholar]
- 31.Strassler HE, Goodman HS. A durable flowable composite resin for preventive resin restorations. Dent Today. 2002;21:116–21. [PubMed] [Google Scholar]
- 32.Gurgan S, Kiremitci A, Cakir FY, Gorucu J, Alpaslan T, Yazici E. et al. Shear bond strength of composite bonded to Er, Cr:YSGG laser-prepared dentin. Photomed Laser Surg. 2008;26(5):495–500. doi: 10.1089/pho.2007.2213. [DOI] [PubMed] [Google Scholar]
- 33.Ramos AC, Esteves-Oliveira M, Arana-Chavez VE, de Paula Eduardo C. Adhesives bonded to erbium:yttrium–aluminum–garnet laser-irradiated dentin: Transmission electron microscopy, scanning electron microscopy and tensile bond strength analyses. Lasers Med Sci. 2010;25(2):181–9. doi: 10.1007/s10103-008-0600-0. [DOI] [PubMed] [Google Scholar]
- 34.Bahrami B, Askari N, Tielemans M, Heysselaer D, Lamard L, Peremans A. et al. Effect of low fluency dentin conditioning on tensile bond strength of composite bonded to Er:YAG laser-prepared dentin: A preliminary study. Lasers Med Sci. 2011;26(2):187–91. doi: 10.1007/s10103-010-0767-z. [DOI] [PubMed] [Google Scholar]
- 35.Dunn WJ, Davis JT, Bush AC. Shear bond strength and SEM evaluation of composite bonded to Er:YAG laser-prepared dentin and enamel. Dent Mater. 2005;21(7):616–24. doi: 10.1016/j.dental.2004.11.003. [DOI] [PubMed] [Google Scholar]
- 36.Tarçin B, Günday M, Oveçoğlu HS, Türkmen C, Oveçoğlu ML, Oksüz M. et al. Tensile bond strength of dentin adhesives on acid- and laser-etched dentin surfaces. Quintessence Int. 2009;40(10):865–74. [PubMed] [Google Scholar]
- 37.Marotti J, Geraldo-Martins VR, Bello-Silva MS, de Paula Eduardo C, Apel C, Gutknecht N. Influence of etching with erbium, chromium:yttrium scandium–gallium–garnet laser on microleakage of class V restoration. Lasers Med Sci. 2010;25(3):325–9. doi: 10.1007/s10103-008-0623-6. [DOI] [PubMed] [Google Scholar]
- 38.De Souza-Gabriel AE, Chinelatti MA, Borsatto MC, Pecora JD, Palma-Dibb RG, Corona SA. Effect of Er ;YAG laser irridiation distance on superficial dentin morphology. Am J Dent. 2006;19(4):217–21. [PubMed] [Google Scholar]
- 39.Gabriel S, Amaral FLB, Pecora JD, Palma Dibb RG, Corona Sam. Shear bond strength of resin modified glass ionomer cements t Er;YAG laser treated tooth structure. Oper Dent. 2006;31(2):212–8. doi: 10.2341/05-13. [DOI] [PubMed] [Google Scholar]
- 40.Keller U, Hibst R. Keller U, Hibst REffects of Er;YAG laser on enamel bonding of composite materialsLaser In Orthopedic. Dental and Veterinary Medicine II. 1993;spie:1880 163–8. [Google Scholar]
- 41.Christensen GJ. Cavity preparation: cutting or air abrasion? . J Am Dent Assoc. 1996;127:1651–4. doi: 10.14219/jada.archive.1996.0102. [DOI] [PubMed] [Google Scholar]
- 42.Lessa FC, Mantovani CP, Barroso JM, Chinelatti MA, Palma-Dibb RG, Pécora JD. et al. Shear bond strength to primary enamel: influence of Er:YAG laser irradiation distance. J Dent Child (Chic) 2007;74(1):26–9. [PubMed] [Google Scholar]
- 43.Başaran G, Hamamcı N, Akkurt A. Shear bond strength of bonding to enamel with different laser irradiation distances. Lasers Med Sci. 2011;26(2):149–56. doi: 10.1007/s10103-009-0747-3. [DOI] [PubMed] [Google Scholar]
- 44.Shahabi Shahabi, Chiniforush N, Bahramian H, Monzavi A, Baghalian A, Kharazifard MJ. The effect of erbium family laser on tensile bond Strengrth of composite to dentin in comparison with conventional method. Lasers Med Sci. 2013;28(1):139–42. doi: 10.1007/s10103-012-1086-3. [DOI] [PubMed] [Google Scholar]
