Skip to main content
Journal of Dentistry (Tehran, Iran) logoLink to Journal of Dentistry (Tehran, Iran)
. 2014 Sep 30;11(5):569–575.

Effect of Pre-heating on Microtensile Bond Strength of Composite Resin to Dentin

Abdolrahim Davari 1, Alireza Daneshkazemi 1, Behnaz Behniafar 2,, Mahsan Sheshmani 2
PMCID: PMC4290777  PMID: 25628684

Abstract

Objective:

Direct composite resin restorations are widely used and the impact of different storage temperatures on composites is not well understood. The purpose of this study was to evaluate the microtensile bond strength of composite to dentin after different pre-curing temperatures.

Materials and Methods:

Occlusal surfaces of 44 human molars were ground with diamond burs under water coolant and polished with 600 grit silicon carbide papers to obtain flat dentin surfaces. The dentin was etched with 37% phosphoric acid and bonded with Adper Single Bond 2 according to the manufacturer's instructions. The specimens were randomly divided into two groups (n=22) according to the composite resin applied: FiltekP60 and Filtek Z250. Each group included three subgroups of composite resin pre-curing temperatures (4°C, 23°C and 37°C). Composite resins were applied to the dentin surfaces in a plastic mold (8mm in diameter and 4mm in length) incrementally and cured. Twenty-two composite-to-dentin hour-glass sticks with one mm2 cross-sectional area per group were prepared. Microtensile bond strength measurements were made using a universal testing machine at a crosshead speed of one mm/min. For statistical analysis, t-test, one-way and two-way ANOVA were used. The level of significance was set at P<0.05.

Results:

Filtek P60 pre-heated at 37ºC had significantly higher microtensile bond strength than Filtek Z250 under the same condition. The microtensile bond strengths were not significantly different at 4ºC, 23ºC and 37ºC subgroups of each composite resin group.

Conclusion:

Filtek P60 and Filtek Z250 did not have significantly different microtensile bond strengths at 4ºC and 23ºC but Filtek P60 had significantly higher microtensile bond strength at 37 ºC. Composite and temperature interactions had significant effects on the bond strength.

Keywords: Composite resin, Microtensile bond strength, Temperatures, Filtek P60, Filtek Z250

INTRODUCTION

The use of composite resins in restorative dentistry has considerably increased in the past decade because of esthetic and mercury-free demands [1]. Composite resins are commonly used for diastema closure, tooth lengthening, masking tooth discolorations and restoring the tooth structure destroyed by caries, abrasion or trauma. Good esthetic properties and adequate durability are the main advantages of dental composites [2]. Many efforts have been made to enhance the mechanical properties of these restorative materials since their introduction in 1960; however, there is still room for further improvement [3]. The major concerns are wear and fracture in consequence of masticatory forces and microleakage as a result of polymerization shrinkage stress [4]. Improving composite-to-tooth bond strength has been the objective of many recent dental researches and several techniques have been investigated for this purpose [2].

Increasing the temperature of the composite before application enhances its flowability, which can be advantageous especially in the case of stiff materials and can help achieve a better adaptation to the cavity wall [59]. Evidence indicates that composite resins have a higher degree of conversion in this situation, which may lead to increased shrinkage [8,10]. This study evaluated the effect of three pre-curing temperatures of two composite resins on composite-to-dentin microtensile bond strength.

MATERIALS AND METHODS

Forty-four extracted sound human molars were randomly collected, cleaned of gross debris and stored in distilled water [11].

The occlusal surfaces were ground horizontally, 2 mm apically to the cementoenamel junction with diamond burs (Diamant GmbH, D&Z, Berlin, Germany) under water coolant to expose the dentin and polished with 600 grit silicon carbide papers for 60 seconds to standardize the smear layer [12].

The teeth were randomly divided into two groups (n=22) according to the composite resin applied; a) Filtek P60 (3M ESPE, St Paul, MN, USA) and b) Filtek Z250 (3M ESPE, St Paul, MN, USA). Separate groups of a and b were further divided into three subgroups based on the pre-curing temperature of 4°C, 23°C and 37°C [13].

The prepared surfaces were acid etched (35% phosphoric acid, Scotch bond etchant, 3M ESPE, St Paul, MN, USA) for 15 seconds. After 15s of water rinsing and gentle air drying [13], the adhesive system Adper Single Bond 2 (3M ESPE, St Paul, MN, USA) was applied in two layers for 10s, with 2–5s gentle air drying and photo polymerized with LED light curing unit (Demi, Kerr, USA) for 10s at 800 mwcm2 intensity [14]. A plastic mold (8mm in diameter and 4mm in length) was fixed approximately at the center of dentin surfaces and the composite resins stored at different temperatures of 4°C (refrigerator), 23°C (room temperature) and 37°C (adjustable heater with a constant thermometer in distilled water) for 30 minutes, were packed into the mold in 2mm increments with a clean plastic filling instrument and light cured (Demi, Kerr, USA) for 40s at 800 mwcm2 using an overlapping technique [13]. After 24 hours of storage at 37 °C distilled water [12], the specimens from each subgroup were mounted in self-cure acrylic resin (Flash Acrylic, Yates Motloid, Chicago, IL, USA) leaving the bonded surface exposed and sectioned into 1mm thick sticks with a trimming device (Vafaee Co., Tehran, Iran) under water coolant at the bonded area, providing 22 sticks per subgroup and a total of 132 sticks (6 subgroups × 22 sticks).

Each stick was cut into one mm2 dentin-to-composite sections with crosshead 008 diamond fissure burs (Diamant GmbH, D&Z, Berlin, Germany) perpendicular to the area preparing hour-glass samples. Each sample was glued at the end of the microtensile testing machine’s jig with cyanoacrylate glue (ASA bond, STS chemical Co, Istanbul, Turkey) and loaded in tension at a crosshead speed of 1 mm/minute in a Universal Testing Machine (SD Mechatronik-MTD-500-Germany) [13]. The load at failure was recorded in Newton [N] and in order to express the bond strength values in MPa the load was divided into the unit area of the composite-dentin interface [15].

Statistical Analysis:

All analyses were processed using SPSS 17 (SPSS Inc., Chicago, Illinois). For statistical analysis, t-test, one-way and two-way ANOVA were used. The level of significance was set at P<0.05.

RESULTS

Two-way ANOVA revealed that different degrees of pre-curing temperatures or the composite type individually had no significant effect on microtensile bond strength but the interaction of the two had a significant effect on the bond strength values (Table 2).

Table 2.

Mean± standard deviation of microtensile bond strength values (MPa) for each group using two-way ANOVA.

Mean± standard deviation P value
Composite Type P60 22.95±9.2 0.181
Filtek 21.1±6.8
Z250

Temperature 4°C 21.3±8.5
23°C 21.5±8.75 0.451
37°C 23.25±7.1

Composite and temperature Interaction ------ 0.022*

• (P<0.05)

• The significance is marked with*

ANOVA was performed for each interaction group and showed a statistically significant difference (P=0.049) among groups (Table 3). T-test showed that the bond strength values were significantly higher using FiltekP60 at 37 °C pre-curing temperature (P=0.003) compared to Filtek Z250 in the same temperature (Table 4).

Table 3.

Mean± standard deviation of microtensile bond strength values (MPa) for interaction groups by ANOVA.

Groups Mean± standard deviation P-Value
1(P60×4°C 22.7±8.5 0.049*
2(P60×23°C) 19.8±10.4
3(P60×37°C) 26.3±7.7
4(Filtek Z250×4°C) 19.9±8.5
5(Filtek Z250×23°C) 23.1±6.5
6(Filtek Z250×37°C) 20.2±4.9

• (P<0.05)

• The significance is marked with*

Table 4.

Mean± standard deviation of microtensile bond strength values (MPa) for each group using t-test and one-way ANOVA.

Composite type Temperature

4°C 23°C 37°C
A(P60) 22.7±8.5a1 19.85±10.42a1 26.72±7.72b1
B(FiltekZ250) 19.88±8.46a1 23.15±6.53a1 20.24±4.87a1

• Superscript letters show differences within the same column (t-test) and numbers within the same row (one-way ANOVA).

• (P<0.05)

Comparison of the effect of pre-curing temperatures on A and B composite groups was done using one-way ANOVA, which revealed no significant difference in microtensile bond strengths.

Although the bond strength values of Filtek P60 increased from 4°C to 37°C and 23°C to 37°C pre-curing temperatures (Table 4).

DISCUSSION

In addition to anterior restorations, composite resins are increasingly used for the posterior teeth [16,17]. The manufacturers have introduced many composite resins with different properties for each area of application [1823]. Comparison of microtensile bond strength of Filtek P60 and Filtek Z250 to dentin with different pre-curing temperatures in this study revealed that Filtek P60 heated at 37°C had a significantly higher bond strength value than Filtek Z250 in the same pre-heated condition. This can be explained by rheology studies, which indicate that composite resins respond to an increase in external temperature by decrease in their viscosity due to their viscoelastic nature [2426].

A reduction in the viscosity of two composite resins due to a pre-heating temperature of 37°C resulted in higher microtensile bond strength of Filtek P60 to dentin. The raising temperature enhanced flow in consequence of thermal energy that increases the molecular mobility of monomer chains and increases the collision frequency in the composite resin [2]. Daronch and Rueggeberg also reported that higher molecular mobility and reduced viscosity due to increased temperature are correlated with the decrease in film thickness of composite resin [8].

The photo polymerized composite resins when exposed to light, are subjected to free radical polymerization and may undergo shrinkage while setting [2].

The polymerization reaction is related to the temperature and higher temperatures increase the degree of conversion, which may improve the physical properties of composite resins [2]. Studies indicate that higher degree of conversion is due to raised temperature compared to room temperature photo polymerization and at this temperature the composite resin needs less time to set [8,9].

As shown in Table 1, Filtek P60 is a packable composite with nearly the same composition as that of Filtek Z250 as a microhybrid composite, but the filler content is 83% for P60 and 82% for Z250 in weight. This 1% increase of filler content, means 6% decrease in resin matrix of P60, which causes differences between the two composites in terms of handling and viscosity [27].

Table 1.

Characteristics of composite resins used in the study (manufacturers’ data).

Materials Manufacturer Shade Material type Matrix Filler size in µm Filler volume (%) Filler weight (%)
Filtek P60 3M, St Paul, MN, USA A2 Packable Composite BIS-GMA, UDMA and BIS-EMA 0.01–3.5 61 83
Filtek Z250 3M, St Paul, MN, USA A2 Hybrid Composite BIS-GMA, UDMA and BIS-EMA 0.01–3.5 60 82

The higher microtensile bond strength of P60 can be attributed to the higher filler content, when pre-heated at 37°C, causing optimal viscosity and flowability which results in deeper penetration of resin into the micro-retentive areas [13] and significantly increases the bond strength.

However no significant differences were found between the microtensile bond strengths of the two composites to dentin at 4°C and 23°C, which can be attributed to similar molecular mobility and consequently identical microtensile bond strengths to dentin.

In this study, the pre-cured temperature of each composite resin did not have any significant effect on the microtensile bond strength although the mean value in Filtek P60 increased. Therefore, the null hypothesis was rejected. As Novell et al. mentioned, this result can be explained by rapid change in composite temperature during application [28]. Daronch et al. also reported that the temperature drops about 50% in 2 minutes removing the composite heated up to 60°C from the heating device. Therefore, the composite resins should be applied rapidly [29].

A noteworthy finding of this investigation was that the composite and temperature interactions had significant impacts on microtensile bond strength of composite-to-dentin but not individually (P=0.022), which can be due to the function of inorganic fillers that reinforce the organic matrix and its mobility in relation to the materials’ temperature.

Pappachini et al, in a study compared composite-to-composite microtensile bond strength repaired with three intermediate agents at pre-curing temperatures of 4°C, 23°C and 37°C, and revealed that the temperature, the intermediate agent and their interaction had significant effects on the bond strength. The bond strength improved by increasing the temperature from 4°C to 23°C [13]. In the current study, the same pre-curing temperatures did not have a significant effect on the bond strength values. The bond strength tests were performed between different types of composites and dentin.

In another study Foes-Salgado et al. revealed that raising the temperature from 25°C to 68°C had a significant effect on marginal adaptation of Filtek Z350 due to energy density but did not affect other mechanical properties [14]. Compared to the current study, different composite types and temperatures were tested and different mechanical properties were evaluated.

Further studies are required to evaluate the composite-to-dentin bond strength under clinical conditions.

CONCLUSION

Within the limitations of this in-vitro study, pre-heating of Filtek P60 as a packable composite at 37°C can achieve significantly higher microtensile bond strength compared to Filtek Z250 as a microhybrid composite.

Acknowledgments

This paper was based on a research submitted to the School of Dentistry, Shahid Sadoughi University of Yazd. This study was financially supported by Shahid Sadoughi University of Medical Sciences, Yazd, Iran.

REFERENCES

  • 1.Roulet JF, Degrange M. Composite resin restorations in posterior teeth, in Adhesion: the silent revolution in dentistry. Chicago: Quintessence. 2000;15:253–76. [Google Scholar]
  • 2.Deb S, Di Silvio L, Mackler HE, Millar BJ. Pre-warming of dental composites. Dent Mater. 2011 Apr;27(4):e51–9. doi: 10.1016/j.dental.2010.11.009. Epub 2010 Dec 9. [DOI] [PubMed] [Google Scholar]
  • 3.Santana IL, Lodovici E, Matos JR, Medeiros IS, Miyazaki CL, Rodrigues-Filho LE. Effect of experimental heat treatment on mechanical properties of resin composites. Braz Dent J. 2009;20:205–10. doi: 10.1590/s0103-64402009000300006. [DOI] [PubMed] [Google Scholar]
  • 4.Mante F, Saleh N, Mante M. Softening of post-cure heat-treated dental composites. Dent Mater. 1993 Sep;9(5):325–31. doi: 10.1016/0109-5641(93)90051-q. [DOI] [PubMed] [Google Scholar]
  • 5.Lovell LG, Newman SM, Bowman CN. The effects of light intensity, temperature, and co-monomer composition on the polymerization behavior of dimethacrylate dental resins. J Dent Res. 1999 Aug;78(8):1469–76. doi: 10.1177/00220345990780081301. [DOI] [PubMed] [Google Scholar]
  • 6.Lovell LG, Berchtold KA, Elliot JE. Understanding the kinetics and network formation of dimethacrylate dental resins. Polym Adv Technol. 2001;12:335–45. [Google Scholar]
  • 7.Trujillio M, Newman SM, Stansbury JW. Use of near-ir to monitor the influence of external heating on dental composite photopolymerization. Dent Mater. 2004 Oct;20(8):766–77. doi: 10.1016/j.dental.2004.02.003. [DOI] [PubMed] [Google Scholar]
  • 8.Daronch M, Rueggberg FA, De Goes MF. Monomer conversion of pre-heated composite. J Dent Res. 2005 Jul;84(7):663–7. doi: 10.1177/154405910508400716. [DOI] [PubMed] [Google Scholar]
  • 9.Daronch M1, Rueggeberg FA, De Goes MF, Giudici R. Polymerization kinetics of pre-heated composite. J Dent Res. 2006 Jan;85(1):38–43. doi: 10.1177/154405910608500106. [DOI] [PubMed] [Google Scholar]
  • 10.Versluis A, Tantbirojn D, Douglas WH. Distribution of transient properties during polymerization of a light-initiated restorative composite. Dent Mater. 2004 Jul;20(6):543–53. doi: 10.1016/j.dental.2003.05.006. [DOI] [PubMed] [Google Scholar]
  • 11.Arici S, Arici N. Effects of thermocycling on the bond strength of a resin-modified glass ionomer cement: an in vitro comparative study. Angle Orthod. 2003 Dec;73(6):692–6. doi: 10.1043/0003-3219(2003)073<0692:EOTOTB>2.0.CO;2. [DOI] [PubMed] [Google Scholar]
  • 12.Borges GA, Spohr AN, Oliveira WJ, Correr-Sobrinho L, Correr AB, Borges LH. Effect of refrigeration on bond strength of self-etching adhesive systems. Braz Dent J. 2006;17:186–90. doi: 10.1590/s0103-64402006000300002. [DOI] [PubMed] [Google Scholar]
  • 13.Papacchini F, Magni E, Radovic I, Mazzitelli C, Monticelli F, Goracci C, et al. Effect of Intermediate Agents and Pre-heating of Repairing Resin on Composite-repair Bonds. Oper Dent. 2007 Jul-Aug;32(4):363–71. doi: 10.2341/06-105. [DOI] [PubMed] [Google Scholar]
  • 14.Fróes-Salgado NR, Silva LM, Kawano Y, Francci C, Reis A, Loguercio AD. Composite pre-heating: Effects on marginal adaptation, degree of conversion and mechanical properties. Dent Mater. 2010 Sep;26(9):908–14. doi: 10.1016/j.dental.2010.03.023. Epub 2010 Jun 16. [DOI] [PubMed] [Google Scholar]
  • 15.Botega DM, Sanchez JL, Mesquita MF, Henriques GE, Consani RL. Effects of thermocycling on the tensile bond strength of three permanent soft denture liners. J Prosthodont. 2008 Oct;17(7):550–4. doi: 10.1111/j.1532-849X.2008.00342.x. Epub 2008 Aug 26. [DOI] [PubMed] [Google Scholar]
  • 16.Pazinatto FB, Gionordoloi Neto R, Wang L, Mondelli J, Mondelli RF, Navarro MF. 56-month clinical performance of Class I and II resin composite restorations. J Appl Oral Sci. 2012 May-Jun;20(3):323–8. doi: 10.1590/S1678-77572012000300005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Papadogiannis D, Tolidis K, Lakes R, Papadogiannis Y. Viscoelastic properties of low-shrinking composite resins compared to packable composite resins. Dent Mater J. 2011;30(3):350–7. doi: 10.4012/dmj.2010-181. Epub 2011 May 20. [DOI] [PubMed] [Google Scholar]
  • 18.Obici AC, Sinhoreti MA, Correr-Sobrinho L, Góes MF, Consani S. evaluation of mechanical properties of Z250 composite resin light-cured by different methods. J Appl Oral Sci. 2005 Dec;13(4):393–8. doi: 10.1590/s1678-77572005000400015. [DOI] [PubMed] [Google Scholar]
  • 19.Asmussen E. Restorative resins: hardness and strength vs quantity of remaining double bonds. Scand J Dent Res. 1982 Dec;90(6):484–9. doi: 10.1111/j.1600-0722.1982.tb00766.x. [DOI] [PubMed] [Google Scholar]
  • 20.Ferracane JL, Greener EH. The effect of resin formulation on the degree of conversion and mechanical properties of dental restorative resins. J Biomed Mater Res. 1986 Jan;20(1):121–31. doi: 10.1002/jbm.820200111. [DOI] [PubMed] [Google Scholar]
  • 21.Ikejima I, Nomoto R, McCabe JF. Shear punch strength and flexural strength of model composites with varying filler volume fraction, particle size and silanation. Dent Mater. 2003 May;19(3):206–11. doi: 10.1016/s0109-5641(02)00031-3. [DOI] [PubMed] [Google Scholar]
  • 22.Lovell LG, Lu H, Elliott JE, Stansbury JW, Bowman CN. The effect of cure rate on the mechanical properties of dental resins. Dent Mater. 2001 Nov;17(6):504–11. doi: 10.1016/s0109-5641(01)00010-0. [DOI] [PubMed] [Google Scholar]
  • 23.Rueggeberg FA, Craig RG. Correlation of parameters used to estimate monomer conversion in a light-cured composite. J Dent Res. 1988 Jun;67(6):932–7. doi: 10.1177/00220345880670060801. [DOI] [PubMed] [Google Scholar]
  • 24.Lee JH, Um CM, Lee IB. Rheological properties of resin composites according to variations in monomer and filler composition. Dent Mater. 2006 Jun;22(6):515–26. doi: 10.1016/j.dental.2005.05.008. Epub 2005 Sep 19. [DOI] [PubMed] [Google Scholar]
  • 25.Barnes HA, Hutton JF, Walters K. An introduction to rheology. Elsevier; New York: 1989. [Google Scholar]
  • 26.Lee IB, Son HH, Um CM. Rheological properties of flowable, conventional hybrid, and condensable composite resins. Dent Mater. 2003 Jun;19(4):298–307. doi: 10.1016/s0109-5641(02)00058-1. [DOI] [PubMed] [Google Scholar]
  • 27. Website: http://www.fahl.com.br/arquivos/Filtek%20Z250%20and%20Filtek%20P60.pdf. Visited at: 2013/24/07.
  • 28.Lovell LG, Newman SM, Bowman CN. The effects of light intensity, temperature, and comonomer composition on the polymerization behavior of dimethacrylate dental resins. J Dent Res. 1999 Aug;78(8):1469–76. doi: 10.1177/00220345990780081301. [DOI] [PubMed] [Google Scholar]
  • 29.Daronch M, Rueggeberg FA, Moss L, de Goes MF. Clinically relevant issues related to preheating composites. J Esthet Restor Dent. 2006;18(6):340–50. doi: 10.1111/j.1708-8240.2006.00046.x. discussion 351. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Dentistry (Tehran, Iran) are provided here courtesy of Tehran University of Medical Sciences

RESOURCES