Skip to main content
Iranian Endodontic Journal logoLink to Iranian Endodontic Journal
. 2014 Dec 24;10(1):44–48.

A CBCT Assessment of Apical Transportation in Root Canals Prepared with Hand K-Flexofile and K3 Rotary Instruments

Zahra Sadat Madani a, Daryoush Goudarzipor b, Azam Haddadi c, Akam Saeidi d,*, Ali Bijani e
PMCID: PMC4293580  PMID: 25598809

Abstract

Introduction: Apical transportation changes the physical shape and physiologic environment of the root canal terminus. The aim of the present experimental study was to determine the extent of apical transportation after instrumentation with hand K-Flexofile and K3 rotary instruments by means of cone-beam computed tomography (CBCT). Methods and Materials: Forty mesiobuccal root canals of maxillary first molars, with 19-22 mm length and 20-40° canal curvature, were selected and assigned into two preparation groups. The first group was prepared with K-Flexofile with passive step-back technique and the second group was prepared with K3 rotary instruments. Pre and post instrumentation CBCT images were taken under similar conditions. The amount of root canal transportation was evaluated by Mann-Whitney U test and the chi-square test was used for the qualitative evaluation. Results: The amounts of apical canal transportation with the K3 and K-Flexofile instruments were 0.105±0.088 and 0.150±0.127 mm, respectively with no statistically significant differences. In the manual technique, 25% of the canals had no apical transportation; while 30% of the canals in the K3 group were transportation free. Conclusion: Both systems were able to preserve the initial curvature of the canals and both had sufficient accuracy. Preparation with K3 rotary instruments resulted in apical transportation similar to that of K-Flexofile.

Key Words: Apical Transportation, Cone-Beam Computed Tomography, K3, K-Flexofile, Root Canal Therapy

Introduction

One of the most important steps in root canal treatment is mechanical preparation, debriding the canal and creating a cone-shaped configuration for easy access, effective irrigation and three-dimensional obturation of the root canal space [1]. Regardless of the technique used for debridement, this procedure results in removal of root canal walls, to some extent. Removal of more dentin from one side compared to other side of the canal wall which are located at similar distances from the long axis of the root, results in a procedural error known as canal transportation [2]. Canal transportation results in displacement of the physiologic end of the canal to a new operator-made location on external surface of the root, leading to accumulation of residual debris and microorganisms [3]. Moreover, this procedural error compromises the uniformity of the root and reduces its fracture resistance and finally results in poor prognosis of treatment [4]. Continuing debridement of the transported path by larger files creates a tear drop appearance at the apical area of the canal and might result in lateral perforation of the root [5]. The shape created due to canal transportation does not provide a resistant form to condense gutta-percha which leads to poor compaction and over-extension of gutta-percha [3]. Deviation from the initial form of the root canal, especially in the apical area, prevents proper obturation and seal against bacterial penetration, which can potentially result in treatment failure.

Besides development of various techniques for the debridement of the root canal that could eliminate such problems, some modifications have been suggested in instruments design. Engine driven instruments can shorten the treatment sessions and reduce the practitioner and patient’s tiredness. However, these systems have some drawbacks including straightening of the root canal, absence of a tactile sensation, inadequate debridement and the risk of file fracture [6].

In 1982 Kerr manufacturing company introduced the K-Flexofile, a departure from the square and triangular configurations [7]. This special cross-section design presents significant changes in instrument flexibility and cutting characteristics. The cutting edges of the high flutes are formed by the two acute angles of the rhombus and present increased sharpness and cutting efficiency. The alternating low flutes formed by the obtuse angles of the rhombus are meant to act as an auger, providing more area for increasing the reservoir that, with proper irrigation, increases debris removal. The decreased contact between the instrument and canal walls provides a space for compacting dentinal filings within the canal [8].

The use of stainless steel hand files produces a high level of procedural errors. Introduction of nickel-titanium (NiTi) rotary instruments has provided easier and faster canal instrumentation and has minimized the procedural errors and operator fatigue [9] and enhanced the success rate of root canal treatment in comparison with stainless steel hand instruments [10]. K3 Endo NiTi rotary file system (Sybron Endo, Orange, CA, USA) was introduced in 2002. These files are designed with a wide radial land and slightly positive rake angle [11]. This file has a variable core diameter designed to increase its flexibility, and a safe-ended tip to decrease the incidence of ledging, perforation and zipping [11].

Recently, noninvasive techniques such as cone-beam computed tomography (CBCT) have been utilized to evaluate canal anatomy and shape before and after preparation at different levels [12]. At present, CT scanners have become a popular and routine technique in the evaluation of shaping ability of new endodontic systems due to their practicality and non-destructive nature [13-15]. CBCT images are highly accurate compared to conventional techniques and do not involve destruction of the specimen, have high reproducibility, and can provide several images from the canals [2, 16-18].

Considering the advantages of CBCT in evaluation of apical transportation [19], the aim of this experimental study was to compare apical transportation in root canals instrumented with hand K-Flexofile to K3 rotary instruments using CBCT technique.

Materials and Methods

The research protocol was approved by the Ethics committee of Babol University of Medical Sciences, Babol, Iran (Grant No. 303150). In this study, 40 extracted human maxillary first molars with fully developed apices were obtained with the length of mesiobuccal (MB) canals being in the range of 19-22 mm and canal curvature being within 20 to 40 degrees, measured according to the Schneider’s method [20]. The teeth were kept in 0.1% thymol solution at 9°C for disinfection, and 24 h prior to the process, they were washed with running tap water to eliminate traces of thymol and were then stored in normal saline at 4°C. Standard straight-line access cavities were prepared and the MB canals were located. Then, for each tooth a #10 K-File (Dentsply Maillefer, Ballaigues, Switzerland) with RC-Prep (Premier Dental Products, Philadelphia, USA) was inserted into the MB canal until it became visible from the apical foramen. Subsequently, the working length was determined 1 mm short of this length to preserve the apical constriction. The teeth were mounted in dental stone blocks to facilitate instrumentation and to enable the reproducibility of pre- and post-operative CBCT images.

The teeth were randomly divided into two groups (n=20). The coronal segment of the canals was prepared using sizes 1 to 3 Gates-Glidden drills (Dentsply Maillefer, Ballaigues, Switzerland). In addition, 2 mL of 2.5% NaOCl was used during instrumentation of the canals in both groups.

Group 1 (hand instrumentation)

In this group, the MB canals were debrided with hand K-Flexofile (Dentsply Maillefer, Ballaigues, Switzerland) using the passive step-back technique. Debridement continued up to #30 file as the master apical file (MAF).

Group 2 (rotary technique)

In this group, the MB canals were debrided with K3 rotary file system (Sybron Endo, Orange, CA, USA) using an electric motor (Endo-Mate TC, NSK, Nakanishi Inc., Tokyo, Japan) set at a speed of 300 rpm and torque of a 2 Nm based on manufacturer’s instructions. Apical preparation was performed with files 25/0.10, 25/0.08, 40/0.04, 35/0.04 and 30/0.04. Each file series was discarded after use in one MB canal or when any defect or deformation was observed in the shape or structure of the file. Instrumentation was carried out by the same operator in both groups. The operator prepared 5 canals each day so that a constant and uniform force would be applied during canal preparation and operator fatigue would not exert any effect on the results.

Evaluation of transportation

Before starting canal preparation, 3-dimensional, high resolution CBCT images were obtained using of Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The 0.5 mm layers of images were taken axially, with 3 mm distance from the radiographic apices and perpendicular to the long axis of the roots.

The images were evaluated using the specific software (OnDemand 3D software, Cybermed Inc, Irvine, CA). A1 and B1 measurements were made using the method introduced by Gambill et al. [21] as follows: A1; the minimum distance between the external surface of the root section and the mesial external surface of the uncleaned root canal and B1; the minimum distance between the external surface of the root section and the distal external surface of the uncleaned root canal. The measurements were repeated three times during one week in order to increase the accuracy and calibration. The images were saved in a computer for comparison with images after canal instrumentation.

After preparation, CBCT images were taken exactly in the same manner. A2 and B2 measurements were defined as A2; the minimum distance between the external surface of the root section and the mesial external surface of the cleaned root canal and B2; the minimum distance between the external surface of the root section and the distal external surface of the cleaned root canal. The amount of transportation was calculated according to the following formula: [(A1-A2)-(B1-B2)]. After insertion of the values in the formula, if the resultant value was zero, there was no apical transportation. Any value other than zero indicated canal transportation.

Data of the two groups were evaluated by the Mann-Whitney U test and the chi-square test was used for the qualitative evaluation of transportation. The level of significance was set at 0.05.

Results

Based on the results of the present study, the mean±SD of apical transportation with K-Flexofile and K3 instruments was 0.150±0.127 and 0.105±0.088 mm, respectively with no statistically significant differences between the two groups (P=0.20) (Table 1).

Table 1.

Mean (SD) of apical transportation values in two groups

Group N Mean (SD) P -value
K-Flexofile 20 0.150 (0.127) 0.20
K3 20 0.105 (0.088)

K-Flexofiles resulted in apical transportation in 75% of the samples; and K3 files resulted in apical transportation in 70% of the specimens. The chi-square test did not reveal any significant differences in terms of apical transportation (Table 2).

Table 2.

Frequency of apical transportations in the root canals prepared by K-Flexofile and K3 files

Group Apical transportation
Absent N (%) Present N (%) Total N (%)
K-Flexofile 5 (25) 15 (75) 20 (100)
K3 6 (30) 14 (70) 20 (100)
Total 11 (27.5) 29 (72.5) 40 (100)

Also the level of apical transportation in the canal was not significantly different between two groups (Table 3).

Table 3.

Frequencies of apical transportation in root canals prepared with K-Flexofile and K3 instruments in different canal sections

Group Apical Transportation N (%)
Absent 0.1 mm 0.2 mm 0.3 mm 0.4 mm Total
K-Flexofile 5 (25) 6 (30) 5 (25) 2 (10) 2 (10) 20 (100)
K3 6 (30) 8 (40) 5 (25) 1 (5) 0 (0) 20 (100)
Total 11 (27.5) 14 (35) 10 (25) 3 (7.5) 2 (5) 40 (100)

Discussion

The present experimental study compared iatrogenic apical transportation in root canals instrumented with K3 rotary system to hand K-Flexofile. The results showed that both file systems created some apical transportation during root canal preparation; interestingly, there were no significant differences in apical transportation or its distance from the apical foramen, between the manual (K-Flexofile) and rotary systems (K3). It appears that similar to hand instrumentation, the K3 system can preserve root canal centrality.

Oliveira et al. [22] carried out a similar study using CBCT technology and reported no significant differences in terms of apical transportation and canal centering ability between rotary systems and hand stainless steel files. However, similar to the present study higher number of canals without transportation was obtained when using RaCe and K3 rotary instruments.

In a study by Lopez et al. [23] on the amount of apical transportation after canal preparation with three different file systems, hand files resulted in significantly more apical transportation while K3 system resulted in adequate safety in apical preparation and less transportation.

Guelzow et al. [24] compared the centering ability of six rotary systems (RaCe, ProTaper, K3, Hero 642, ProFile GT and FlexMaster) with hand files and reported that in comparison with FlexMaster and K3 files, ProTaper system resulted in greater straightening of the canals. In the present study, both manual and rotary instrumentation exhibited some amounts of apical transportation.

Using computed tomography Ozer et al. [25] found that using rotary systems with non-cutting tips did not reduce the apical transportation. Another similar study showed that preparation of root canals with 28‒35° curvatures using K3 files, resulted in a significant decrease in root canal straightening [26]. In the study by Mokhtary et al. [9], BioRaCe and Mtwo rotary instruments were considered suitable for canal preparation to greater apical sizes compared to K-Flexofile provided that the recommended sequences are observed. Nazari Moghadam et al. [27] found that Twisted File and Reciproc systems did not differ significantly in terms of canal centering ability and transportation. Madani et al. [28] evaluated the root canal transportation after using two rotary systems (Mtwo & ProTaper) using CBCT and found insignificant apical transportation in both systems. Jodway and Hulsmann [29] conducted a study on canal preparation with K3 rotary files and nickel-titanium (NiTi) hand files and showed that the root canals in the K3 group exhibited some canal straightening. The differences in the results might be attributed to the various techniques used to determine the amount of canal transportation.

The results of another study on extracted human teeth showed that the initial shape of canals were better preserved with the use of rotary files compared to K-Flexofile hand instruments [30]. K3 rotary files have been shown to create only a small amount of canal transportation in comparison with K-Flexofile hand instruments which showed greater transportation [26, 31]. Although the present study revealed similar results, the difference was not significant. As preparing canals with K3 rotary files is less time consuming in comparison with hand instrumentation, K3 may still be preferable.

In the present study, each file set was discarded after use in one MB canal or in case of observing any defect or deformation in the shape or structure of files. In separate studies by Akhlaghi et al. [32] and Lopez et al. [33] the files were replaced after preparation of 5 and 3 canals, respectively.

In the present study, the MB root canals of maxillary first molars were evaluated because these canals usually have significant curvatures [2]. In addition, these roots are very narrow which significantly increase the difficulty of preparing these canals [2, 21].

Conclusion

K3 rotary system and K-Flexofile hand instruments can preserve the original canal curvature.

Acknowledgment

The authors would like to thank the Dental School of Babol University of Medical Sciences for their support for the original thesis (Grant no. 303150).

Conflict of Interest: ‘None declared’.

References

  • 1.Karabucak B, Gatan AJ, Hsiao C, Iqbal MK. A comparison of apical transportation and length control between EndoSequence and Guidance rotary instruments. J Endod. 2010;36(1):123–5. doi: 10.1016/j.joen.2009.09.015. [DOI] [PubMed] [Google Scholar]
  • 2.Hartmann MS, Barletta FB, Camargo Fontanella VR, Vanni JR. Canal transportation after root canal instrumentation: a comparative study with computed tomography. J Endod. 2007;33(8):962–5. doi: 10.1016/j.joen.2007.03.019. [DOI] [PubMed] [Google Scholar]
  • 3.Baumgarther IB. Ingle’s Endodontics. 3rd Edition. Hamilton; 2008 pp. [Google Scholar]
  • 4.Schafer E, Dammaschke T. Development and sequelae of canal transportation. Endod Topics. 2006;15(1):75–90. [Google Scholar]
  • 5.Torabinejad M, Walton R. Endodontics principles and practice. 3rd Edition. St. Louis: Saunders; 2009. [Google Scholar]
  • 6.Taşdemir T, Aydemir H, Inan U, Ünal O. Canal preparation with Hero 642 rotary Ni–Ti instruments compared with stainless steel hand K-file assessed using computed tomography. Int Endod J. 2005;38(6):402–8. doi: 10.1111/j.1365-2591.2005.00961.x. [DOI] [PubMed] [Google Scholar]
  • 7.Brau-Aguade E, Canalda-Sahli C, Berastegui-Jimeno E. Cutting efficiency of K-files manufactured with different metallic alloys. Endod Dent Traumatol. 1996;12(6):286–8. doi: 10.1111/j.1600-9657.1996.tb00528.x. [DOI] [PubMed] [Google Scholar]
  • 8.Haikel Y, Gasser P, Allemann C. Dynamic fracture of hybrid endodontic hand instruments compared with traditional files. J Endod. 1991;17(5):217–20. doi: 10.1016/S0099-2399(06)81924-2. [DOI] [PubMed] [Google Scholar]
  • 9.Mokhtari H, Niknami M, Sohrabi A, Habibivand E, Mokhtari Zonouzi HR, Rahimi S, Zand V. Cone-Beam Computed Tomography Comparison of Canal Transportation after Preparation with BioRaCe and Mtwo Rotary Instruments and Hand K-Flexofiles. Iran Endod J. 2014;9(3):180–4. [PMC free article] [PubMed] [Google Scholar]
  • 10.Alves RA, Souza JB, Goncalves Alencar AH, Pecora JD, Estrela C. Detection of Procedural Errors with Stainless Steel and NiTi Instruments by Undergraduate Students Using Conventional Radiograph and Cone Beam Computed Tomography. Iran Endod J. 2013;8(4):160–5. [PMC free article] [PubMed] [Google Scholar]
  • 11.Mohammadzade Akhlaghi N, Khalilak Z, Baradaran Mohajeri L, Sheikholeslami M, Saedi S. Comparison of Canal Preparation Pattern of K3 and ProTaper Rotary Files in Curved Resin Blocks. Iran Endod J. 2008;3(2):11–6. [PMC free article] [PubMed] [Google Scholar]
  • 12.Nagaraja S, Murthy BVS. CT evaluation of canal preparation using rotary and hand Ni-Ti instruments: An in vitro study. J Conserv Dent. 2010;13(1):16–22. doi: 10.4103/0972-0707.62636. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Sberna MT, Rizzo G, Zacchi E, Capparè P, Rubinacci A. A preliminary study of the use of peripheral quantitative computed tomography for investigating root canal anatomy. Int Endod J. 2009;42(1):66–75. doi: 10.1111/j.1365-2591.2008.01452.x. [DOI] [PubMed] [Google Scholar]
  • 14.Gao Y, Peters OA, Wu H, Zhou X. An application framework of three-dimensional reconstruction and measurement for endodontic research. J Endod. 2009;35(2):269–74. doi: 10.1016/j.joen.2008.11.011. [DOI] [PubMed] [Google Scholar]
  • 15.Bernardes RA, Rocha EA, Duarte MA, Vivan RR, de Moraes IG, Bramante AS, de Azevedo JR. Root canal area increase promoted by the EndoSequence and ProTaper systems: comparison by computed tomography. J Endod. 2010;36(7):1179–82. doi: 10.1016/j.joen.2009.12.033. [DOI] [PubMed] [Google Scholar]
  • 16.Gergi R, Rjeily JA, Sader J, Naaman A. Comparison of canal transportation and centering ability of twisted files, Pathfile-ProTaper system, and stainless steel hand K-files by using computed tomography. J Endod. 2010;36(5):904–7. doi: 10.1016/j.joen.2009.12.038. [DOI] [PubMed] [Google Scholar]
  • 17.Versiani MA, Pascon EA, de Sousa CJ, Borges MA, Sousa-Neto MD. Influence of shaft design on the shaping ability of 3 nickel-titanium rotary systems by means of spiral computerized tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;105(6):807–13. doi: 10.1016/j.tripleo.2007.12.012. [DOI] [PubMed] [Google Scholar]
  • 18.Howerton Jr WB, Mora MA. Advancements in digital imaging: what is new and on the horizon? J Am Dent Assoc. 2008;139:20–4. doi: 10.14219/jada.archive.2008.0354. [DOI] [PubMed] [Google Scholar]
  • 19.Nazari S, Samavat H, Mirmotalebi F, Shahriari SH. Application of CT-Scan in Evaluation of Transportation of Root Canal during Endodontic Retreatment. Asian J Exp Sci. 2007;21(2):227–32. [Google Scholar]
  • 20.Zhang R, Hu T. Root canal curvature. Int Endod J. 2010;43(7):616–8. doi: 10.1111/j.1365-2591.2010.01727.x. discussion 8-21. [DOI] [PubMed] [Google Scholar]
  • 21.Gambill JM, Alder M, del Rio CE. Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography. J Endod. 1996;22(7):369–75. doi: 10.1016/S0099-2399(96)80221-4. [DOI] [PubMed] [Google Scholar]
  • 22.Oliveira CA, Meurer MI, Pascoalato C, Silva SR. Cone-beam computed tomography analysis of the apical third of curved roots after mechanical preparation with different automated systems. Braz Dent J. 2009;20(5):376–81. doi: 10.1590/s0103-64402009000500004. [DOI] [PubMed] [Google Scholar]
  • 23.Lopez FU, Fachin EV, Camargo Fontanella VR, Barletta FB, So MV, Grecca FS. Apical transportation: a comparative evaluation of three root canal instrumentation techniques with three different apical diameters. J Endod. 2008;34(12):1545–8. doi: 10.1016/j.joen.2008.07.027. [DOI] [PubMed] [Google Scholar]
  • 24.Guelzow A, Stamm O, Martus P, Kielbassa AM. Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation. Int Endod J. 2005;38(10):743–52. doi: 10.1111/j.1365-2591.2005.01010.x. [DOI] [PubMed] [Google Scholar]
  • 25.Özer SY. Comparison of root canal transportation induced by three rotary systems with noncutting tips using computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2011;111(2):244–50. doi: 10.1016/j.tripleo.2010.08.017. [DOI] [PubMed] [Google Scholar]
  • 26.Schafer E, Florek H. Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile Part 1 Shaping ability in simulated curved canals. Int Endod J. 2003;36(3):199–207. doi: 10.1046/j.1365-2591.2003.00643.x. [DOI] [PubMed] [Google Scholar]
  • 27.Nazari Moghadam K, Shahab S, Rostami G. Canal transportation and centering ability of twisted file and reciproc: a cone-beam computed tomography assessment. Iran Endod J. 2014;9(3):174–9. [PMC free article] [PubMed] [Google Scholar]
  • 28.Madani ZS, Haddadi A, Haghanifar S, Bijani A. Cone-beam computed tomography for evaluation of apical transportation in root canals prepared by two rotary systems. Iran Endod J. 2014;9(2):109–12. [PMC free article] [PubMed] [Google Scholar]
  • 29.Jodway B, Hulsmann M. A comparative study of root canal preparation with NiTi-TEE and K3 rotary Ni-Ti instruments. Int Endod J. 2006;39(1):71–80. doi: 10.1111/j.1365-2591.2005.01059.x. [DOI] [PubMed] [Google Scholar]
  • 30.Bertrand MF, Lupi-Pegurier L, Medioni E, Muller M, Bolla M. Curved molar root canal preparations using Hero 642 rotary nickel-titanium instruments. Int Endod J. 2001;34(8):631–6. doi: 10.1046/j.1365-2591.2001.00440.x. [DOI] [PubMed] [Google Scholar]
  • 31.Schafer E, Schlingemann R. Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile Part 2 Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth. Int Endod J. 2003;36(3):208–17. doi: 10.1046/j.1365-2591.2003.00644.x. [DOI] [PubMed] [Google Scholar]
  • 32.Akhlaghi N, Khalilak Z, Mehrabian F. The effect of intermediate Flexofile Golden Mediums on apical transportation of the curved canals. Dent J Shahid Beheshti University of Medical Sciences. 2008;26(1) [Google Scholar]
  • 33.Lopes HP, Elias CN, Estrela C, Siqueira Jr JF. Assessment of the apical transportation of root canals using the method of the curvature radius. Braz Dent J. 1998;9(1):39–45. [PubMed] [Google Scholar]

Articles from Iranian Endodontic Journal are provided here courtesy of Iranian Center for Endodontic Research

RESOURCES