Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 2015 Jan 23;53(2):618–625. doi: 10.1128/JCM.02443-14

Utility of Real-Time PCR for Detection of Exserohilum rostratum in Body and Tissue Fluids during the Multistate Outbreak of Fungal Meningitis and Other Infections

Lalitha Gade a, Dale E Grgurich b, Thomas M Kerkering b, Mary E Brandt a, Anastasia P Litvintseva a,
Editor: D J Diekema
PMCID: PMC4298529  PMID: 25520443

Abstract

Exserohilum rostratum was the major cause of the multistate outbreak of fungal meningitis linked to contaminated injections of methylprednisolone acetate produced by the New England Compounding Center. Previously, we developed a fungal DNA extraction procedure and broad-range and E. rostratum-specific PCR assays and confirmed the presence of fungal DNA in 28% of the case patients. Here, we report the development and validation of a TaqMan real-time PCR assay for the detection of E. rostratum in body fluids, which we used to confirm infections in 57 additional case patients, bringing the total number of case patients with PCR results positive for E. rostratum to 171 (37% of the 461 case patients with available specimens). Compared to fungal culture and the previous PCR assays, this real-time PCR assay was more sensitive. Of the 139 identical specimens from case patients tested by all three methods, 19 (14%) were positive by culture, 41 (29%) were positive by the conventional PCR assay, and 65 (47%) were positive by the real-time PCR assay. We also compared the utility of the real-time PCR assay with that of the previously described beta-d-glucan (BDG) detection assay for monitoring response to treatment in case patients with serially collected CSF. Only the incident CSF specimens from most of the case patients were positive by real-time PCR, while most of the subsequently collected specimens were negative, confirming our previous observations that the BDG assay was more appropriate than the real-time PCR assay for monitoring the response to treatment. Our results also demonstrate that the real-time PCR assay is extremely susceptible to contamination and its results should be used only in conjunction with clinical and epidemiological data.

INTRODUCTION

Since September 2012, U.S. state and local health departments, the Centers for Disease Control and Prevention (CDC), and the Food and Drug Administration have been investigating the largest documented health care-associated outbreak in the United States of fungal meningitis and other infections developed after epidural, paraspinal, or joint injections with contaminated methylprednisolone acetate (MPA) from a single compounding pharmacy (13). The major cause of this outbreak was Exserohilum rostratum, a plant pathogen that rarely causes disease in humans (4). By using culture, PCR, and histopathology, this fungus was identified in cerebrospinal fluid (CSF), synovial fluid, abscess aspirate, fresh tissue, and formalin-fixed, paraffin-embedded tissue samples from 153 case patients, as well as in unopened vials of two implicated lots of MPA (3). Previously, we developed a method for extracting free circulating fungal DNA from different types of body fluids and tissues from patients in this outbreak and used two PCR tests, followed by DNA sequencing, to detect fungal DNA in patient specimens (5). Using this approach, we were able to detect fungal DNA in 28% of the case patients (3). Although the sensitivity of the PCR assay was considerably better than that of culture, which was able to confirm only 10% of the cases, a large percentage of the case patients remained without laboratory confirmation of infection. We also investigated the utility of the Fungitell assay for the detection of beta-d-glucan (BDG) in CSF for diagnosis and monitoring of the response to treatment (6). Using this assay and a stratified sample of CSF specimens, we demonstrated that approximately 45% of the CSF specimens from case patients with negative PCR assay results had elevated levels of BDG. Our results, as well as others, also demonstrated that consistently elevated levels of BDG in CSF may indicate a relapse or persistent infection (6, 7). However, because the BDG assay is not species specific, can cross-react with certain bacteria and drugs, and is prone to contamination, this test cannot be used to provide a definitive confirmation of fungal infection (6, 8). A real-time molecular beacon PCR assay for detection of Exserohilum has also been reported (9) and used to test blood from patients with a possible association with the outbreak (10).

Here, we report the development of a quantitative real-time PCR assay using TaqMan technology for detection of the internal transcribed spacer 2 (ITS2) ribosomal DNA region of E. rostratum. We report the results of sensitivity and specificity testing of this novel real-time PCR assay and compare its utility with that of previously reported conventional PCR and BDG detection assays.

MATERIALS AND METHODS

Human subjects.

This investigation was considered a public health emergency response and therefore was not subject to review by the CDC's Institutional Review Board.

Case definitions.

A proven case was defined as a probable case with evidence (by culture, histopathology, or molecular assay) of a fungal pathogen associated with the clinical syndrome. A probable case was defined as the development of any of the following: meningitis of unknown etiology following epidural or paraspinal injection after 21 May 2012; posterior circulation stroke without a cardioembolic source and without documentation of a normal CSF profile following epidural or paraspinal injection after 21 May 2012; osteomyelitis, abscess, or other infection (e.g., soft tissue infection) of unknown etiology in the spinal or paraspinal structures at or near the site of injection following epidural or paraspinal injection after 21 May 2012; or osteomyelitis or worsening inflammatory arthritis of a peripheral joint (e.g., knee, shoulder, or ankle) of unknown etiology diagnosed following joint injection after 21 May 2012 in a person who received an injection with preservative-free MPA that definitely or likely came from one of the following three lots produced by the New England Compounding Center: 05212012@68, 06292012@26, or 08102012@51. These case definitions have been previously described (3, 11).

Clinical specimens.

This study included specimens received between 2 October 2012 and 31 December 2013. A total of 898 specimens from 471 case patients were tested, including CSF, synovial fluid, abscess aspirate, and tissue fluid samples. All of these specimens were previously tested with two conventional PCR assays as previously described (5). Fresh tissues; formalin-fixed, paraffin-embedded tissue; and isolates were excluded. Serially collected CSF samples from 20 case patients whose specimens were previously tested for BDG detection were included to evaluate the utility of our real-time PCR assay for monitoring of the response to treatment (6, 12).

DNA extraction from CSF, synovial fluid, and abscess aspirates.

Body fluids such as CSF, synovial fluid, and abscess aspirates were processed as previously described (5). Briefly, cells and particulate matter were pelleted by centrifugation and removed and free DNA was captured with the QIAamp UltraSens virus kit (Qiagen, Hilden, Germany) according to the manufacturer's instructions but with modifications described previously (5). The same DNA extractions were used for conventional and real-time PCRs. DNA was stored at −80°C and thawed twice prior to testing. Early in the outbreak, some remnant samples that had not been kept frozen were sent for analysis. Otherwise, specimens were frozen as soon as possible after collection, shipped on dry ice to the CDC, and kept at −80°C until testing.

DNA extraction from fresh-frozen tissue fluids.

Fresh-frozen tissues were received from a variety of sources, including the brain, meninges, epidural tissue, epidural abscess debridement material, cysts, and bone in sterile saline. Specimens were centrifuged, and the supernatants were processed in accordance with the body fluid protocol described previously (5).

Real-time PCR primers and probe.

To select specific real-time PCR primers and a probe, we used Mega 5.0 (13) to generate alignments of sequences from the ITS2 region of the E. rostratum outbreak strains and other fungi associated with the outbreak (14), as well as E. rostratum and 11 species of phylogenetically related and clinically relevant fungi, such as Bipolaris sp. and Alternaria sp., from GenBank. Regions specific to Exserohilum were selected and used to select probes and primers with Primer 3 (http://frodo.wi.mit.edu/) and E. rostratum strain TA26-49 ITS DNA (NCBI accession number JF819166.1). The real-time PCR primers used were EXS 1F (5′-TTG TCT CTC CCC TTG TTG G-3′) and EXS 1R (5′-CCG CCC CGT GGA TTG GAA-3′), and the probe was 5′-FAM-TTG GCA GCC GAC CTA CTG GTT TT-BHQ1-3′, where FAM is 6-carboxyfluorescein and BHQ is the Black Hole Quencher. The specificity of the primer and probe sequences selected was tested by BLAST by using the NCBI nucleotide collection (nr/nt) database, and no significant similarity to any other reliably identified species of fungi was detected.

Real-time PCR assay.

A 25-μl reaction mixture contained 12.5 μl of 2× TaqMan universal master mix (Applied Bio-Systems, Gaithersburg, MD), 0.2 μM each primer, 0.1 μM TaqMan probe, and 5 μl of template DNA. Reactions were performed with a Rotor-Gene real-time instrument (Qiagen RG 6000) under cycling conditions including an initial denaturation step at 95°C for 5 min, followed by 45 cycles of 95°C for 15 s, 54°C for 30 s, and 72°C for 10 s, with data collection in the FAM channel. Each run included one Exserohilum genomic template control and at least two no-template controls. All of the specimen DNAs were tested in duplicate.

Analytical specificity of the real-time PCR primers and probe.

The analytical specificity of the primers and probe used was tested with E. rostratum DNAs extracted from 21 E. rostratum isolates from case patients, 6 isolates from MPA vials, and 7 E. rostratum strains from the CDC collection. We also tested DNA extracted from 12 non-Exserohilum fungal pathogens recovered from case patients from this outbreak, such as Alternaria alternata, Aspergillus fumigatus, Aspergillus terreus, Aspergillus tubingensis, Chaetomium sp., Cladosporium cladosporioides, Cladosporium sp., Epicoccum nigrum, Paecilomyces niveus, Penicillium panem, Scopulariopsis brevicaulis, and Stachybotrys chartarum (14), as well as other clinically relevant fungi, such as Fusarium sp. and Candida albicans. In addition, we tested DNAs extracted from body fluids positive for other fungi by the conventional PCR assay, such as C. cladosporioides, Cladosporium sp., E. nigrum, Alternaria sp., and Malassezia restricta.

Determination of LOD.

PCR products were cloned into the pCR 2.1 TA vector (Invitrogen, Carlsbad, CA) according to the manufacturer's instructions, linearized by digestion with HindIII (New England Bio Labs, Ipswich, MA) according to the manufacturer's instructions, purified with the QIAquick PCR purification kit (Qiagen, Hilden, Germany), and used to prepare 10-fold serial dilutions containing 107 to 10 plasmid copies per reaction mixture. A standard curve was generated with Rotor-Gene Q Series Software 2.0.2 (SA Biosciences Qiagen) and used to calculate PCR efficiency and linear dynamic range; the experiment was performed in triplicate. The lowest concentration of DNA that could be reliably detected was considered the limit of detection (LOD) of this method.

Estimation of reproducibility.

Assay reproducibility was tested by comparing CT values obtained on 3 different days with replicate 10-fold serial dilutions of the linearized plasmid DNA and measured by calculating the coefficient of variation (CV) of the mean CT values between runs. Precision was evaluated for each dilution point by comparing variability among triplicates and measuring the CV of the mean CT values within runs.

Determination of diagnostic sensitivity and specificity.

To calculate diagnostic sensitivity, we compared the performance of the real-time PCR assay with that of culture and previously developed broad-spectrum and E. rostratum-specific conventional PCR assays with 139 previously described CSF samples from proven and probable cases with known PCR assay and culture results (5). Positive-control specimens were specimens that had been demonstrated positive for E. rostratum by conventional PCR assay (n = 41) and/or culture (n = 19). Diagnostic specificity was calculated by using 66 negative-control specimens from patients who were not considered case patients in the outbreak. To test for the possibility of cross-contamination during sample handling, we tested 61 sterile distilled-water samples that were processed along with the patient specimens and subjected to the same DNA extraction procedures.

RESULTS

Analytical specificity of real-time PCR primers and probes.

Identical PCR amplification patterns were obtained with DNA extracted from 34 different strains of E. rostratum (data not shown). No amplification (CT value of 0) was obtained when DNA from 15 other fungal species or control human DNA was used.

LOD and amplification efficiency.

The LOD was approximately 10 copies per reaction, which corresponded to a CT value of 40 ± 0.3. Strong linear correlations (r2, >0.99) were obtained between CT values and target copy numbers over a 7-log range (10 to 107 copies per reaction) with 98% amplification efficiency (see Fig. S1 in the supplemental material).

Reproducibility.

Assay reproducibility was tested by using replicate 10-fold serial dilutions of the linearized plasmid DNA, and intra- and interassay variability was evaluated for each dilution point in triplicate on 3 different days. The CVs of the mean CT values within and between runs were 0.20 to 1.5% and 0.2 to 2.9%, respectively (Table 1).

TABLE 1.

Reproducibility of real-time PCR assay results

Comparison CV (%) with DNA copy no.a of:
10 102 103 104 105 106 107
Within assayb 0.9 0.5 0.2 0.4 1.2 1.5 0.5
Between assaysc 0.3 2.4 1.1 1.6 2.2 2.3 2.9
a

Tenfold dilutions of linearized plasmid DNA were used, numbers of copies per reaction mixture are shown, dilution series were thawed on 3 different days, and assays were performed in triplicate for each dilution.

b

Determined from three replicates within each assay.

c

Determined from three independent assays performed on different days.

Diagnostic sensitivity of broad-spectrum PCR, real-time PCR, and culture.

Specimens from 139 case patients were tested by culture, conventional PCR, and real-time PCR to assess the diagnostic sensitivity of each method (Table 2). Sixty-five (47%) of these specimens were positive by real-time PCR, 41 (29%) were positive by conventional PCR assays, and 19 (14%) were positive by culture (5). All of the specimens positive by conventional PCR assays and/or culture were also positive by real-time PCR assay. Furthermore, five specimens that were positive by culture but negative by conventional PCR assays in previous testing also were positive by real-time PCR assay. In addition, 19 specimens that were negative by both conventional PCR assays and culture were positive by real-time PCR assay (Table 2).

TABLE 2.

Comparison of real-time and conventional PCR assay and culture results obtained with 139 samples

Result(s) by test(s) performed No. (%) positive
Real-time PCR and culture positive, conventional PCR negative 5 (4)
Real-time PCR and conventional PCR positive, culture negative 27 (19)
Positive by all 3 methods 14 (10)
All conventional PCR positive 41 (29)
All culture positive 19 (14)
All real-time PCR positive 65 (47)
Real-time PCR positive only 19 (14)

Diagnostic specificity of the real-time PCR assay.

To determine the specificity of the assay, we tested 61 control water samples that were subjected to the same DNA extraction procedure as the patient specimens (5). For 54 (89% of 61) of these samples, no amplification was observed after 45 cycles (CT value 0); however, a low level of E. rostratum DNA (CT value of 42 or 43) was detected in 7 (11% of 61) samples (data not shown). Furthermore, we tested 66 CSF samples from patients not considered case patients in the outbreak. For 56 (85% of 66) of these samples, no amplification was observed after 45 cycles of PCR (CT value of 0); however, low levels of E. rostratum DNA were detected (CT values of 41 to 45) in 10 (15% of 66) of these samples (data not shown). On the basis of these observations, CT values of ≤40 were considered positive, CT values of 41 to 45 were considered indeterminate, and a CT value of 0 (>45) was considered a negative result.

Results of real-time PCR assay.

Between October 2012 and December 2013, 898 CSF, synovial fluid, abscess aspirate, and tissue fluid samples from 471 case patients were tested by the broad-range and E. rostratum-specific conventional PCR assays and DNA sequencing (5). Of those, 888 specimens from 461 case patients were available for real-time PCR testing. Ten samples tested previously by the conventional PCR assay were not tested by the real-time PCR assay because of an insufficient specimen or DNA quantity.

A total of 209 samples (24% of the samples tested) collected from 171 case patients (37% of the 461 case patients) were found to be positive for E. rostratum DNA by real-time PCR assay (Table 3). Positive results were obtained for 174 CSF samples from 138 case patients (38% of the 359 case patients with CSF samples), 7 synovial or abscess fluid samples from 6 case patients (21% of the 30 case patients with synovial fluid specimens), and 28 tissue fluid samples from 27 case patients (33% of the 82 case patients with tissue fluid specimens) (Table 3). The median CT value for the positive samples was 37.6. Most of the real-time PCR assay-positive specimens (193 [92%] of 209 positive specimens) were received in October to December of 2012.

TABLE 3.

Conventional and real-time PCR assays results presented by patient and by sample

Results for: No. of samples tested No. positive (%) by:
Conventional PCR Real-time PCR
All case patients 471 114 (24) 171 (37)a
    CSF samples 359 83 (23) 138 (38)b
    Synovial fluids, abscess aspirates 30 5 (17) 6 (21)c
    Tissue fluid samples 82 26 (33) 27 (36)
All case specimens 898 123 (14) 209 (24)a
    CSF samples 729 91 (13) 174 (24)b
    Synovial fluids, abscess aspirates 48 5 (11) 7 (15)c
    Tissue fluid samples 121 27 (22) 28 (25)d
a

Ten specimen DNA samples were not tested because the quantity was not sufficient.

b

Two CSF DNA samples were not tested.

c

One abscess aspirate DNA sample was not tested.

d

Seven tissue fluid DNA samples were not tested; fresh and formalin-fixed, paraffin-embedded tissues were excluded.

Testing of serial CSF samples.

Results obtained by conventional PCR assay, real-time PCR assay, and measurement of BDG levels in CSF were compared among 20 case patients from whom samples were serially collected as described previously (6) (Table 4). Both conventional and real-time PCR assays were more likely to detect fungal DNA in the incident CSF samples than in samples serially collected later (Table 4). Specifically, incident CSF samples from 11 case patients were positive by conventional PCR assay and 18 were positive by real-time PCR assay. In addition, the real-time PCR assay detected E. rostratum DNA in two subsequent CSF specimens collected from patients 5 and 17 approximately 1 month after the first samples were collected. Furthermore, both the conventional and real-time PCR assays detected E. rostratum DNA in the CSF of patient 3 after he relapsed with meningitis (Table 4) (15). However, all three serially collected CSF samples from patient 4, who developed a soft tissue phlegmon, were positive by the real-time PCR assay, while only the incident CSF from this patient was positive by the conventional PCR assay. All of the CSF samples positive by the real-time PCR assay also had elevated BDG levels (Table 4). Furthermore, in most of the case patients, elevated BDG levels persisted for an additional 3 to 5 months when the real-time PCR assay results were indeterminate or negative (Table 4).

TABLE 4.

Test results and demographic and clinical information for patients with serially collected CSF samplesa

Patient no., sex,b age (yr), and LPc date (day, mo, yr) Result of:
CT No. of WBCd/ml Mean BDG level (pg/ml) ± SDe Clinical outcome
Culture PCR Real-time PCR
1, F, 42
    17 Oct. 2012 Negf E. rostratum E. rostratum 33 2,507 NPg Multiple strokes, deceased
    7 Nov. 2012 Neg Neg Neg 0 1,330 >500
    10 Dec. 2012 Neg Neg Neg 0 104 NP
    15 Jan. 2013 Neg Neg Neg 0 57 >500
2, F, 64
    7 Oct. 2012 Neg Neg Indh 43 2,576 >500 Relapse meningitis, on retreatment, stable
    7 Nov. 2012 Neg Neg Neg 0 177 >500
    6 Feb. 2013 Neg Neg Neg 0 0 >500
    16 May 2013 Neg C. cladosporioides Neg 0 513 >500
    30 May 2013 Neg Neg Neg 0 145 >500
3,i M, 80
    4 Oct. 2012 Neg Neg E. rostratum 38 119 >500 Relapse meningitis, on treatment, stable
    17 Oct. 2012 Neg Neg Neg 0 63 >500
    30 Nov. 2012 Neg Neg Neg 0 9 488 ± 11
    11 Jan. 2013 Neg Neg Neg 0 5 246 ± 75
    11 Mar. 2013 Neg E. rostratum E. rostratum 36 2,075 >500
4, F, 77
    9 Oct. 2012 Neg E. rostratum E. rostratum 30 2,550 >500 Relapse soft tissue phlegmon, on retreatment, stable
    8 Nov. 2012 Neg Neg E. rostratum 40 34 >500
    5 Dec. 2012 Neg Neg E. rostratum 38 0 >500
5, M, 72
    5 Oct. 2012 Neg E. rostratum E. rostratum 34 1,989 >500 Completed treatment, asymptomatic, stable
    19 Dec. 2012 Neg Neg E. rostratum 39 5 >500
    13 Feb. 2013 Neg Neg Neg 0 2 387 ± 33
    3 Apr. 2013 Neg Neg Neg 0 7 218 ± 4
6, M, 69
    4 Oct. 2012 Neg Neg E. rostratum 33 664 >500 Completed treatment, asymptomatic, stable
    5 Dec. 2012 Neg Neg Neg 0 14 >500
    6 Mar. 2013 Neg Neg Neg 0 0 383 ± 32
7, F, 64
    11 Oct. 2012 Neg E. rostratum E. rostratum 30 3,996 >500 Completed treatment, asymptomatic, stable
    25 Oct. 2012 Neg Neg Ind 41 43 NP
    2 Jan. 2013 Neg Neg Neg 0 7 >500
    6 Feb. 2013 Neg Neg Ind 44 5 438 ± 23
    8 Apr. 2013 Neg Neg Neg 0 5 408 ± 32
    15 Jul. 2013 Neg Neg Neg 0 3 252 ± 103
8, M, 44
    15 Oct. 2012 Neg E. rostratum E. rostratum 39 602 NP Completed treatment, asymptomatic, stable
    28 Nov. 2012 Neg Neg Neg 0 85 >500
    4 Jan. 2013 Neg Neg Neg 0 7 >500
    25 Feb. 2013 Neg Neg Neg 0 14 391 ± 14
    1 Apr. 2013 Neg Neg Neg 0 5 457 ± 61
    6 May 2013 Neg Neg Neg 0 8 <32
9, F, 75
    22 Oct. 2012 E. rostratum E. rostratum E. rostratum 31 NP NP Completed treatment, asymptomatic, stable
    12 Nov. 2012 Neg Neg Ind 44 3,106 >500
    23 Nov. 2012 Neg Neg Ind 43 10 412 ± 3
    1 Feb. 2013 Neg Neg Ind 42 14 238 ± 2
    8 Mar. 2013 Neg Neg Neg 0 2 120 ± 25
10, F, 84
    4 Oct. 2012 Neg Neg E. rostratum 34 2,676 >500 Continues on treatment (8 mo), stable
    21 Nov. 2012 Neg Neg Neg 0 66 >500
    1 Mar. 2013 Neg Neg Neg 0 17 >500
    5 Apr. 2013 E. nigrum Neg Neg 0 157 427 ± 35
    26 Apr. 2013 Neg Neg Neg 0 48 240 ± 14
    28 May 2013 Neg Neg Neg 0 43 <32 
11, M, 65
    4 Oct. 2012 Neg E. rostratum E. rostratum 28 1,828 >500 Completed treatment, asymptomatic, stable
    2 Nov. 2012 Neg Neg Neg 0 71 235 ± 17
    9 Jan. 2013 Neg Neg Neg 0 2 <32
    7 Feb. 2013 Neg Neg Neg 0 0 41 ± 9
    8 May 2013 Neg Neg Neg 0 0 <32
12, F, 58
    29 Sep. 2012 C. cladosporioides Neg Neg 0 9,080 >500 Completed treatment, asymptomatic, stable
    22 Oct. 2012 Neg Neg Neg 0 173 NP
    21 Dec. 2012 Neg Neg Neg 0 2 112 ± 5
    21 Mar. 2013 Neg Neg Neg 0 7 55
13, M, 77
    8 Oct. 2012 Neg E. rostratum E. rostratum 30 1,530 >500 Completed treatment, asymptomatic, stable
    9 Nov. 2012 Neg Neg Ind 42 6,373 >500
    3 Jan. 2013 Neg Neg Neg 0 65 >500
    5 Feb. 2013 Neg Neg Neg 0 5 104 ± 0
    5 Apr. 2013 Neg Neg Neg 0 17 129 ± 21
    20 Apr. 2013 Neg Neg Neg 0 7 45 ± 0
14, M, 50
    4 Oct. 2012 E. rostratum E. rostratum E. rostratum 32 830 >500 Continues on treatment (8 mo),stable
    8 Nov. 2012 Neg Neg Neg 0 418 >500
    18 Dec. 2012 Neg Neg Neg 0 121 >500
    12 Mar. 2013 Neg Neg Neg 0 50 32 ± 61
    3 Jun. 2013 Neg Neg Neg 0 16 335
    5 Aug. 2013 Neg Neg Neg 0 157 385 ± 25
15, M, 70
    5 Oct. 2012 Neg Neg E. rostratum 39 2,610 >500 Completed treatment, asymptomatic, stable
    8 Nov. 2012 Neg Neg Neg 0 7 297 ± 20
    12 Dec. 2012 Neg Neg Neg 0 2 241 ± 18
    6 Feb. 2013 Neg Neg Neg 0 0 69 ± 12
    5 Apr. 2013 Neg Neg Neg 0 0 123 ± 2
16, M, 61
    8 Oct. 2012 Neg Neg Ind 43 280 >500 Completed treatment, asymptomatic, stable
    12 Nov. 2012 Neg Neg Neg 0 52 385 ± 75
    5 Dec. 2012 Neg Neg Neg 0 0 41 ± 1
    4 Mar. 2013 Neg Neg Neg 0 0 <32
    10 May 2013 Neg Neg Neg 0 0 <32
17, F, 55
    24 Oct. 2012 Neg E. rostratum E. rostratum 34 48 >500 Completed treatment, asymptomatic, stable
    28 Nov. 2012 E. nigrum Neg E. rostratum 38 954 >500
    23 Jan. 2013 Neg Neg Ind 41 0 110 ± 4
    1 Apr. 2013 Neg Neg Neg 0 2 50 ± 4
18, F, 92
    15 Oct. 2012 Neg Neg E. rostratum 36 28 486 ± 20,124 Completed treatment, asymptomatic, stable
    19 Nov. 2012 Neg Neg Neg 0 2 426 ± 269
    22 Jan. 2013 Neg Neg Ind 42 5 278 ± 11
    1 May 2013 Neg Neg Neg 0 2 266 ± 14
19, M, 16
    29 Oct. 2012 Neg E. rostratum E. rostratum 30 710 450 ± 14 Completed treatment, asymptomatic, stable
    12 Dec. 2012 Neg Neg Neg 0 90 >500
    21 Jan. 2013 Neg Neg Neg 0 12 171 ± 52
    17 May 2013 Neg Neg Neg 0 6 <32
20, F, 63
    11 Oct. 2012 Neg Neg E. rostratum 39 777 >500 Completed treatment, asymptomatic, stable
    30 Oct. 2012 Neg Neg Neg 0 475 >500
    18 Feb. 2013 Neg Neg Neg 0 33 280 ± 8
    15 May 2013 Neg Neg Neg 0 5 296 ± 18
a

Only lumbar punctures with culture, PCR assay, and/or BDG results are included.

b

F, female; M, male.

c

LP, lumbar puncture. Lumbar puncture dates for patients 1, 4, 8, and 9 were adjusted compared to a previous report (6) based on clinical data review.

d

WBC, white blood cells.

e

Mean values and standard deviations of three readings are shown. The CSF BDG positive cutoff was determined to be 138 pg/ml (6).

f

Neg, negative.

g

NP, not performed.

h

Ind, indeterminate.

i

Reference 12.

DISCUSSION

The 2012 multistate outbreak of fungal meningitis and other infections has been the largest iatrogenic outbreak in U.S. history and is still affecting the lives of hundreds of people. By 23 October 2013 in 20 states, 752 cases were identified, resulting in 64 deaths. CDC laboratories were able to confirm fungal infections in 173 case patients (33% of the case patients from whom specimens were submitted to the CDC) by histopathology, PCR assay, or culture (3, 14). In addition, with input from the Infectious Diseases Society of America and an advisory group of experts in clinical mycology, the CDC developed treatment guidelines for physicians treating patients in the outbreak (11, 16). Although the recommended clinical management of both confirmed and probable cases in the outbreak was the same, there was a need to develop a more sensitive diagnostic test to better understand the etiology of this outbreak. Our previously developed conventional PCR assays were able to detect fungal DNA in 114 case patients with available body fluid specimens (25% of the case patients for whom specimens were submitted to the CDC) (5). Here, we report the development of a novel real-time PCR assay for detection of Exserohilum DNA in case patients in the outbreak and provide laboratory confirmation of Exserohilum infection in 57 additional case patients.

The greater sensitivity of the real-time PCR assay than the conventional PCR assay was not surprising, since the real-time PCR assay did not rely on the visualization of PCR products on an agarose gel, and therefore, lower concentrations of PCR products could be detected with this method. We observed an excellent correlation between conventional and real-time PCR assay results, as all of the samples positive by the conventional PCR assay were also positive by the real-time PCR assay. In addition, all of the samples positive by culture were also positive by the real-time PCR assay, and five samples that were positive by culture but negative by conventional PCR assay were positive by the real-time PCR assay.

There are at least three limitations of this real-time PCR assay. First, this assay is specific to Exserohilum and cannot be used to detect other fungal DNAs. Several other fungi have been implicated in the outbreak; however, their clinical significance remains to be determined (10, 14). Our results are consistent with previous observations that E. rostratum is the main etiological agent of this outbreak (10, 14), as its DNA was detected in body fluids or tissues of 37% of the case patients tested. Second, extracting fungal DNA from patient specimens remains the main challenge for this molecular detection method, since PCR assay sensitivity depends on the efficiency of DNA extraction. Here, we used a DNA extraction method that relies on the purification of free circulating fungal DNA from fluids, which provided the best recovery of fungal DNA from these outbreak samples (5); however, the effectiveness of this method needs to be further evaluated. Third, our results demonstrate that this real-time PCR assay is highly sensitive to contamination. Even miniscule amounts of contaminating DNA introduced during sample collection or handling can interfere with the PCR signal from the fungus causing infection; therefore, molecular results need to be interpreted in combination with clinical and epidemiological data and very low concentrations of DNA cannot be reliably linked to disease.

To minimize the effects of the contamination and cross-contamination that occur during sample collection and handling, we used the following procedures. First, prior to their use in the real-time PCR assay, we tested all of the reagents for the presence of fungal DNA. Surprisingly, we detected Fusarium sp. DNA in several lots of proteinase K, which is used for digestion of human cells and proteins. Second, when processing patient samples for DNA extraction, we included a water control sample with each batch of patient samples and subjected it to the same procedures used to process patient specimens. When these control water samples were tested by the real-time PCR assay, a low level of amplification (CT value of 42 or 43) was detected in 7 (11%) of 61 samples, indicating cross-contamination during extraction.

Recently, there has been an increased interest in using PCR-based methods for the diagnosis of fungal infections in this outbreak and in other patient populations (9, 10, 17, 18). Our data suggest that PCR assay results need to be carefully scrutinized and should be considered only in combination with clinical and epidemiological data. False-positive PCR assay results caused by contamination during sample collection and processing have been reported by others (1921), and our results support these observations. Reagent impurity and contamination during sample collection from skin flora and/or the environment, as well as cross-contamination during DNA extraction and processing, cannot be completely avoided, and therefore, amplification of fungal DNA from a biological sample does not always imply infection. For example, in this outbreak, several other environmental fungi have been detected by PCR assay in CSF and other body fluids and tissues (14). Although some of these agents, such as C. cladosporioides, have been implicated in this outbreak, others, such as common wheat (Triticum sp.) or skin flora M. restricta, which we PCR amplified from the CSF of several case patients (data not shown), were unquestionably contaminants. Recently, Zhao et al. used a real-time PCR assay to detect the presence of fungal DNA in the blood of patients exposed to contaminated MPA; however, the clinical significance of these findings remains unclear (10). Most of the fungi detected by Zhao et al., such as Cryptococcus neoformans or Hortaea werneckii, have never been implicated in this outbreak (3, 12, 14). Although A. fumigatus was isolated from the index case patient (22), extensive screening of more than 1,000 specimens from more than 500 case patients in this outbreak by broad-spectrum fungal PCR assay in our laboratory (14), as well as independent screening with Aspergillus-specific PCR assay at a Virginia hospital (12), failed to detect any evidence of A. fumigatus DNA in any patient other than the index case patient (3). Overall, our experience with PCR and real-time PCR assays suggests that, in the absence of other evidence, detection of trace amounts of fungal or any other foreign DNA in biological samples could be attributed to contamination and cannot be used as a sole argument for infection.

Previously, we tested the utility of BDG detection for monitoring the response to treatment in serially collected CSF samples. Here, we investigated the utility of a real-time PCR assay for monitoring of the patient response to treatment. Our results demonstrated that although the real-time PCR assay was able to detect Exserohilum DNA in a larger number of case patients with serially collected CSF than the conventional PCR assay, in most patients, only CSF samples collected during the early stages of disease were positive by this test. Specifically, Exserohilum DNA was detected by real-time PCR assay in 17 (85%) of 20 case patients with serially collected samples. In 13 (76%) of those patients, only the incident specimens were positive; in 2 (12%, patient 5 and 17), both the incident samples and subsequent samples collected 1 month after the initial diagnosis were positive; and in 1 (6%, patient 3) who relapsed with meningitis, both the incident and relapse CSF samples were positive by real-time PCR assay (Table 4). The only exception was patient 4, who developed a soft tissue phlegmon while she was being treated for meningitis; her CSF was consistently positive for Exserohilum by real-time PCR assay, and she also had consistently elevated levels of BDG in her CSF (Table 4). Overall, our data suggest that, in most patients, the Exserohilum DNA level in CSF declined below the reliable LOD soon after treatment initiation. Detection of Exserohilum DNA may be an indication of relapse or lingering infection, but overall, BDG provides a better marker for monitoring the response to treatment in most patients.

Our results demonstrate that, when used appropriately, a real-time PCR assay can provide a valuable tool for confirming the presence of fungal DNA in patients' specimens. However, this method is highly prone to contamination and should be used with caution and only in combination with clinical and epidemiological data. This outbreak provided a unique opportunity to evaluate different methods for molecular detection of filamentous fungi in clinical samples. Our results indicate that all three of the detection methods tested have limitations and that using a comprehensive approach consisting of a broad-spectrum PCR assay with sequencing, a real-time PCR assay, and BDG testing provided the best strategy for the timely detection, identification, and monitoring of fungal infection in this outbreak. Results obtained in this investigation will help to develop strategies for the diagnosis and treatment of systemic mold infections in the future.

Supplementary Material

Supplemental material

ACKNOWLEDGMENTS

We thank all of the participants in the Multistate Fungal Infection Outbreak Response Team, especially state and local health department officials, clinicians, and health care professionals, who provided clinical samples and data for this investigation. We thank all of the members of the CDC Mycotic Diseases Branch and CDC Emergency Response volunteers for their help with receiving, processing, and cataloging clinical samples, especially Christina Scheel, Cau Pham, Mark Lindsley, Nina Grossman, Joyce Peterson, Carol Bolden, Ngoc Le, Shirley McClinton, Randy Kuykendall, Steve Hurst, Kizee Etienne, Noelle Bessette, Grant Williams, Paris Paul, Sarah Yi, Laura Dickmeyer, and Jessica Halpin. We thank Michael Palmieri of the FDA for providing vial isolates and Deanna Sutton, Michael Rinaldi, and Michael McGinnis for providing control isolates for this study. We thank Rachel Smith, Benjamin Park, and Tom Chiller for critically reading the manuscript.

The use of product names in this report does not imply their endorsement by the U.S. Department of Health and Human Services. The finding and conclusions in this article are those of the authors and do not necessarily represent the views of the CDC.

Footnotes

Supplemental material for this article may be found at http://dx.doi.org/10.1128/JCM.02443-14.

REFERENCES

  • 1.Centers for Disease Control and Prevention. 2012. Multistate outbreak of fungal infection associated with injection of methylprednisolone acetate solution from a single compounding pharmacy—United States, 2012. MMWR Morb Mortal Wkly Rep 61:839–842. http://www.cdc.gov/mmwr/preview/mmwrhtml/mm6141a4.htm. [PubMed] [Google Scholar]
  • 2.Centers for Disease Control and Prevention. 2013. Spinal and paraspinal infections associated with contaminated methylprednisolone acetate injections—Michigan, 2012–2013. MMWR Morb Mortal Wkly Rep 62:377–381. http://www.cdc.gov/mmwr/preview/mmwrhtml/mm6219a1.htm. [PMC free article] [PubMed] [Google Scholar]
  • 3.Smith RM, Schaefer MK, Kainer MA, Wise M, Finks J, Duwve J, Fontaine E, Chu A, Carothers B, Reilly A, Fiedler J, Wiese AD, Feaster C, Gibson L, Griese S, Purfield A, Cleveland AA, Benedict K, Harris JR, Brandt ME, Blau D, Jernigan J, Weber JT, Park BJ, Multistate Fungal Infection Outbreak Response Team . 2013. Fungal infections associated with contaminated methylprednisolone injections. N Engl J Med 369:1598–1609. doi: 10.1056/NEJMoa1213978. [DOI] [PubMed] [Google Scholar]
  • 4.Litvintseva AP, Hurst S, Gade L, Frace MA, Hilsabeck R, Schupp JM, Gillece JD, Roe C, Smith D, Keim P, Lockhart SR, Changayil S, Weil MR, MacCannell DR, Brandt ME, Engelthaler DM. 2014. Whole-genome analysis of Exserohilum rostratum from the outbreak of fungal meningitis and other infections. J Clin Microbiol 52:3216–3222. doi: 10.1128/JCM.00936-14. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Gade L, Scheel CM, Pham CD, Lindsley MD, Iqbal N, Cleveland AA, Whitney AM, Lockhart SR, Brandt ME, Litvintseva AP. 2013. Detection of fungal DNA in human body fluids and tissues during a multistate outbreak of fungal meningitis and other infections. Eukaryot Cell 12:677–683. doi: 10.1128/EC.00046-13. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Litvintseva AP, Lindsley MD, Gade L, Smith R, Chiller T, Lyons JL, Thakur KT, Zhang SX, Grgurich DE, Kerkering TM, Brandt ME, Park BJ. 2014. Utility of (1-3)-beta-d-glucan testing for diagnostics and monitoring response to treatment during the multistate outbreak of fungal meningitis and other infections. Clin Infect Dis 58:622–630. doi: 10.1093/cid/cit808. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Nelson G, Fermo O, Thakur K, Felton E, Bang J, Wilson L, Rhee S, Llinas R, Johnson K, Sullivan D. 2014. Resolution of a fungal mycotic aneurysm after a contaminated steroid injection: a case report. BMC Res Notes 7:327. doi: 10.1186/1756-0500-7-327. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Lyons JL, Roos KL, Marr KA, Neumann H, Trivedi JB, Kimbrough DJ, Steiner L, Thakur KT, Harrison DM, Zhang SX. 2013. Cerebrospinal fluid (1, 3)-β-d-glucan detection as an aid for diagnosis of iatrogenic fungal meningitis. J Clin Microbiol 51:1285–1287. doi: 10.1128/JCM.00061-13. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Zhao Y, Petraitiene R, Walsh TJ, Perlin DS. 2013. A real-time PCR assay for rapid detection and quantification of Exserohilum rostratum, a causative pathogen of fungal meningitis associated with injection of contaminated methylprednisolone. J Clin Microbiol 51:1034–1036. doi: 10.1128/JCM.03369-12. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Zhao Y, Armeanu E, DiVerniero R, Lewis TA, Dobson RC, Kontoyiannis DP, Roilides E, Walsh TJ, Perlin DS. 2014. Fungal DNA detected in blood samples of patients who received contaminated methylprednisolone injections reveals increased complexity of causative agents. J Clin Microbiol 52:2212–2215. doi: 10.1128/JCM.00854-14. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Chiller TM, Roy M, Nguyen D, Guh A, Malani AN, Latham R, Peglow S, Kerkering T, Kaufman D, McFadden J, Collins J, Kainer M, Duwve J, Trump D, Blackmore C, Tan C, Cleveland AA, MacCannell T, Muehlenbachs A, Zaki SR, Brandt ME, Jernigan JA, Multistate Fungal Infection Clinical Investigation Team . 2013. Clinical findings for fungal infections caused by methylprednisolone injections. N Engl J Med 369:1610–1619. doi: 10.1056/NEJMoa1304879. [DOI] [PubMed] [Google Scholar]
  • 12.Kerkering TM, Grifasi ML, Baffoe-Bonnie AW, Bansal E, Garner DC, Smith JA, Demicco DD, Schleupner CJ, Aldoghaither RA, Savaliya VA. 2013. Early clinical observations in prospectively followed patients with fungal meningitis related to contaminated epidural steroid injections. Ann Intern Med 158:154–161. doi: 10.7326/0003-4819-158-3-201302050-00568. [DOI] [PubMed] [Google Scholar]
  • 13.Tamura K, Peterson D, Peterson N, Stecher G, Nei M, Kumar S. 2011. MEGA5: molecular evolutionary genetics analysis using maximum likelihood, evolutionary distance, and maximum parsimony methods. Mol Biol Evol 28:2731–2739. doi: 10.1093/molbev/msr121. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Lockhart SR, Pham CD, Gade L, Iqbal N, Scheel CM, Cleveland AA, Whitney AM, Noble-Wang J, Chiller TM, Park BJ, Litvintseva AP, Brandt ME. 2013. Preliminary laboratory report of fungal infections associated with contaminated methylprednisolone injections. J Clin Microbiol 51:2654–2661. doi: 10.1128/JCM.01000-13. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Smith RM, Tipple M, Chaudry MN, Schaefer MK, Park BJ. 2013. Relapse of fungal meningitis associated with contaminated methylprednisolone. N Engl J Med 368:2535–2536. doi: 10.1056/NEJMc1306560. [DOI] [PubMed] [Google Scholar]
  • 16.Centers for Disease Control and Prevention. 2012. Multistate fungal meningitis outbreak—interim guidance for treatment. MMWR Morb Mortal Wkly Rep 61:842 http://www.cdc.gov/mmwr/preview/mmwrhtml/mm6141a5.htm. [PubMed] [Google Scholar]
  • 17.Zhao Y, Perlin DS. 2013. Quantitative detection of Aspergillus spp. by real-time nucleic acid sequence-based amplification. Methods Mol Biol 968:83–92. doi: 10.1007/978-1-62703-257-5_6. [DOI] [PubMed] [Google Scholar]
  • 18.Millon L, Larosa F, Lepiller Q, Legrand F, Rocchi S, Daguindau E, Scherer E, Bellanger AP, Leroy J, Grenouillet F. 2013. Quantitative polymerase chain reaction detection of circulating DNA in serum for early diagnosis of mucormycosis in immunocompromised patients. Clin Infect Dis 56:e95–e101. doi: 10.1093/cid/cit094. [DOI] [PubMed] [Google Scholar]
  • 19.Kami M, Fukui T, Ogawa S, Kazuyama Y, Machida U, Tanaka Y, Kanda Y, Kashima T, Yamazaki Y, Hamaki T. 2001. Use of real-time PCR on blood samples for diagnosis of invasive aspergillosis. Clin Infect Dis 33:1504–1512. doi: 10.1086/323337. [DOI] [PubMed] [Google Scholar]
  • 20.Millon L, Grenouillet F, Crouzet J, Larosa F, Loewert S, Bellanger A-P, Deconinck E, Legrand F. 2010. False-positive Aspergillus real-time PCR assay due to a nutritional supplement in a bone marrow transplant recipient with GVH disease. Med Mycol 48:661–664. doi: 10.3109/13693780903451836. [DOI] [PubMed] [Google Scholar]
  • 21.Cuenca-Estrella M, Meije Y, Diaz-Pedroche C, Gomez-Lopez A, Buitrago MJ, Bernal-Martinez L, Grande C, San Juan R, Lizasoain M, Rodriguez-Tudela JL. 2009. Value of serial quantification of fungal DNA by a real-time PCR-based technique for early diagnosis of invasive aspergillosis in patients with febrile neutropenia. J Clin Microbiol 47:379–384. doi: 10.1128/JCM.01716-08. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Pettit AC, Kropski JA, Castilho JL, Schmitz JE, Rauch CA, Mobley BC, Wang XJ, Spires SS, Pugh ME. 2012. The index case for the fungal meningitis outbreak in the United States. N Engl J Med 367:2119–2125. doi: 10.1056/NEJMoa1212292. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplemental material

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES