The current status of an FDG-PET cancer screening program in Japan, based on a 4-year (2006–2009) nationwide survey

Ryogo Minamimoto 1,15,, Michio Senda 2, Seishi Jinnouchi 3, Takashi Terauchi 4, Tsuyoshi Yoshida 5, Takeshi Murano 4, Hiroshi Fukuda 6, Takeshi Iinuma 7, Kimiichi Uno 8, Sadahiko Nishizawa 9, Eriko Tsukamoto 10, Hiroshi Iwata 11, Takeshi Inoue 12, Kazuhiro Oguchi 13, Rumi Nakashima 14, Tomio Inoue 15
PMCID: PMC4328108  PMID: 23086544

Abstract

Objective

The aim of this study was to survey the 18F-fluorodeoxyglucose-positron emission tomography (FDG-PET) cancer screening program conducted in Japan.

Methods

The “FDG-PET cancer screening program” included both FDG-PET and positron emission tomography with computed tomography (PET/CT) with or without other combined screening tests that were performed for cancer screening in asymptomatic subjects. A total of 155,456 subjects who underwent the FDG-PET cancer screening program during 2006–2009 were analyzed.

Results

Of the 155,456 subjects, positive findings suggesting possible cancer were noted in 16,955 (10.9 %). The number of cases with detected cancer was 1,912 (1.23 % of the total screened cases, annual range 1.14–1.30 %). Of the 1,912 cases of detected cancer, positive findings on FDG-PET were present in 1,491 cases (0.96 % of the total number of screened cases). According to the results of further examinations, the true positive rate for subjects with suggested possible cancer (positive predictive value) was 32.3 % with FDG-PET. Cancers of the colon/rectum, thyroid, lung, and breast were most frequently found (396, 353, 319, and 163 cases, respectively) with high PET sensitivity (85.9, 90.7, 86.8, 84.0 %, respectively). Prostate cancer and gastric cancer (165 and 124 cases, respectively) had low PET sensitivity (37.0 and 37.9 %, respectively). The Union for International Cancer Control (UICC) clinical stage of cancer found with the FDG-PET cancer screening program was mainly Stage I.

Conclusions

The FDG-PET screening program in Japan has detected a variety of cancers at an early stage. However, several cancers were found in repeated FDG-PET cancer screening program, indicating the limitation of a one-time FDG-PET cancer screening program. The value of the FDG-PET cancer screening program is left to the judgment of individuals with regard to its potentials and limitations.

Keywords: FDG, PET, PET/CT, Cancer screening

Introduction

Screening is the investigation of a group of asymptomatic individuals in order to detect a disease that has a high probability of development. The National Cancer Institute (NCI) estimates that appropriate cancer screening can prevent 3–35 % of premature deaths caused by cancer. The NCI suggests that cancer screening might decrease cancer morbidity because treatment for earlier-stage cancers is often less aggressive than that for more advanced cancers. Only a few screening methods have evidence supporting their use in reducing cancer-related mortality [1].

Fluorine-18 fluorodeoxyglucose (FDG)-positron emission tomography (PET) and positron emission tomography/computed tomography (PET/CT) have had a considerable impact in the field of oncology in terms of differentiating between benign and malignant tumors, staging cancers, evaluating the effectiveness of treatment, and predicting prognosis. PET and PET/CT can provide whole-body imaging, and have the potential to reveal malignancies anywhere in the body. The performance of FDG-PET for cancer screening was first published by the HIMEDIC Imaging Center at Lake Yamanaka. They established a cancer screening program which consisted of an FDG-PET examination combined with screening tests such as ultrasonography and computed tomography to compensate for the limitations of FDG-PET [2]. Since then, cancer screening using FDG-PET based on Yamanaka’s method has become widespread in Japan, and is performed in more than 130 facilities. The performance profile of FDG-PET cancer screening in 2005 was reported. A total of 43,996 healthy subjects underwent FDG-PET (including PET/CT) scanning with or without other tests for cancer screening in 38 PET centers in Japan [3]. The yearly survey was continued until 2009 in Japan. PET cancer screening is more widespread than before, and PET/CT scanners were more widely used than ever. The potential of the FDG-PET cancer screening program is investigated in the present report through the results of 155,456 cases that underwent FDG-PET cancer screening from 2006 to 2009. This report aims at clarifying the performance of FDG-PET cancer screening, but does not attempt to confirm nor deny the effectiveness of the PET cancer screening program as a cancer screening method.

Materials and methods

Subjects

All study protocols in this retrospective observation study were approved by our institutional review board. Questionnaires regarding the FDG-PET cancer screening program were obtained from subjects who had undergone FDG-PET and/or other combined screening tests, and were referred for further evaluation. Subjects underwent FDG-PET cancer screening in a total of 233 facilities (2006, 59; 2007, 57; 2008, 58; and 2009, 59). The total number of subjects was 43,061 (25,594 men and 17,467 women) in 2006, 39,867 (23,948 men and 15,919 women) in 2007, 38,929 (23,055 men, 15,230 women, and 644 gender unidentified) in 2008, and 33,599 (20,142 men and 13,457 women) in 2009 for a total of 155,456 (92,739 men, 62,073 women, and 644 unidentified) from a total of 233 facilities. Results based on these 155,456 cases are discussed in the present report. The facilities that participated in the questionnaire survey are listed in Table 1.

Table 1.

Cooperated PET centers for the survey

Asahikawa-Kosei General Hospital University of Fukui Hospital Tsukazaki Clinic
Keiyukai Sapporo Hospital Sugita Genpaku Memorial Obama Municipal Hospital Institute of Biomedical Research and Innovation
Sapporo Minamisanjo Hospital Fukui Red Cross Hospital Himeji Central Hospital’s Clinic
Central CI Clinic Fukui-ken Saiseikai Hospital Agape Kabutoyama Hospital
LSI Sapporo Clinic Iida Municipal Hospital Sumoto Itsuki Hospital
Tomakomai City Hospital Aizawa Hospital Kouseikai Takai Hospital
Aomori PET Diagnostic Imaging Center Ichinose Neurosurgical Hospital Nishinokyo Hospital
Akita Research Institute of Brain and Blood Vessels Kizawame Memorial Hospital Wakayama-minami Radiology Clinic
Sendai Kousei Hospital Juntendo University Shizuoka Hospital Tottori University Hospital
Kousei Sendai Clinic Seirei Hamamatsu General Hospital Tottori Municipal Hospital
Southern Tohoku General Hospital, Miyagi Hamamatsu Medical Imaging Center Kawasaki Medical School Hospital
Southern Tohoku General Hospital, Fukushima Nagoya Central Hospital Kurashiki Central Hospital
Shirakawa Kosei General Hospital Daiyukai Daiichi Hospital Tsuyama Central Hospital
Dokkyo Medical University Hospital KARIYA TOYOTA General Hospital Okayama Diagnostic Imaging Center
Utsunomiya Central Clinic Nagoya PET Imaging Center Okayama Kyokuto Hospital
Kusunoki Hospital East Nagoya Imaging Diagnosis Center Okamura Isshindow Hospital
Saitama Medical University Koseikai Hospital Chuden Hospital
Tokorozawa PET Diagnostic Imaging Clinic Handa Medical Association Health Care Center Hiroshima Heiwa Clinic
Asahi General Hospital Mie University Hospital St. Hill Hospital
Sannou Medical Center Iga City Medical Checkup Center Tokushima University Hospital
Yotsukaido Tokushukai Hospital Saiseikai Matsusaka General Hospital Kagawa University Hospital
Nippon Medical School Clinical Imaging Center for Healthcare Mie Advanced Medical PET Center Takinomiya General Hospital
National Center for Global Health and Medicine Kusatsu General Hospital Shikoku Cancer Center
Toranomon Hospital Oumikusatsu Tokusyukai Hospital Ehime Prefectural Central Hospital
Japanese Foundation for Cancer Research Cancer Screening Center Nishijin Hospital Kochi University Hospital
Nishidai Clinic Mitsubishi Kyoto Hospital Kyushu University Hospital
Yotsuya Medical Cube Takeda Oncologic Positron Imaging Center Kurume University School of Medicine
Musashimurayama Hospital Kinki University Institute of Advanced Clinical Medicine Kouhoukai Takagi Hospital
Iwai Medical Foundation Medicheck Imaging Center Saiseikai Nakatsu Hospital, Osaka Koga Hospital 21
Yuai Clinic Panasonic Health Care Center Fukuoka Wajiro PET Diagnostic Imaging Clinic
Shonan-Atsugi Clinic Hanwa Intelligent Medical Center Kitakyushu PET Center
General Sagami Kosei Hospital Higashitemma Clinic Nishi Isahaya Hospital
Toyama PET Imaging Center OCAT Clinic Saiseikai Kumamoto Hospital
Public Central Hospital of Matto Ishikawa HIMEDIC Clinic West Oita Diagnostic Imaging Center
Asanogawa General Hospital MI Clinic Kagoshima-kyousaikai Nanpuh Hospital
Tousenkai Healthcare System Keiju PET-CT, Linac Center Morinomiya Clinic Atsuchi Memorial Clinic
Kanazawa Cardiovascular Hospital Ishikiriseiki Hospital

Contents of the investigation

The questionnaire regarding the FDG-PET cancer screening consists of an “Investigation of facilities” section that describes the situation of each facility, and an “Investigation of suspected cancer cases” section that describes the inspection of suspected cancer cases. The “Investigation of facilities” section surveyed the following areas: (1) the type and methods of FDG-PET (FDG-PET machines, injected radioactive of FDG, presence and method of attenuation correction, time to obtain PET or PET/CT, screening range, performance of delayed scanning and start time); (2) characteristics of the CT scanner integrated in the PET/CT system (mAs, CT image reconstruction interval); (3) fixed or optional other cancer screening tests combined with FDG-PET; (4) total number, gender, and age of subjects who underwent FDG-PET cancer screening; (5) number of repeated annual FDG-PET cancer screening (at least 2 consecutive years); (6) number, gender, age of subjects with positive findings by FDG-PET and/or combined screening test suggesting possible cancer; (7) number of positive/negative findings by FDG-PET and/or combined screening tests in the case of suggested possible cancer; (8) number of excluded cancer cases with combined screening tests after cancer was suspected by FDG-PET.

Detailed information was required only for possible cancer cases in the “Investigation of suspected cancer cases” section. Five types of investigation sheets were provided: “lung cancer,” “colon/rectum cancer,” “thyroid cancer,” and “breast cancer” (which are all frequently detected by FDG-PET), and “other cancers”. The “Investigation of suspected cancer cases” section asked about the following: (1) gender; (2) age; (3) past history of cancer; (4) with or without of repeated annual FDG-PET cancer screening and other suspected cancers by previous FDG-PET screening if any; (5) findings of FDG-PET and delayed imaging if present; (6) results of the combined cancer screening tests; and (7) final results of further detailed examinations. The “Investigation of suspected cancer cases” section consisted of three categories, namely, “proved cancer,” “excluded cancer,” and “strict follow-up because of disproved cancer.”

Definition of terms

In this article, the term “FDG-PET” is defined as an examination performed with a PET scanner or PET/CT scanner. “FDG-PET cancer screening program” is defined as a cancer screening program using FDG-PET that is aimed at the detection of cancer at an early stage. Any PET or PET/CT detector, FDG-PET method, combined screening test, and method of further examination were included in the present report. Any method of selecting subjects and of handling the associated expense burden was allowed. Cases with a past history of cancer, or screening for recurrence requested by the attending physician or patient were excluded from the present report. However, when the cancer was considered to have been cured and FDG-PET was performed to screen for other sites of cancer, the FDG-PET test was included. “Combined screening tests,” defined by each PET center, were those undergone by more than half of the subjects who underwent FDG-PET cancer screening at each PET center. If a screening test was performed at another facility within a short interval and the results were provided to the PET center, it was included in category of “combined screening tests.” If further examination was judged necessary on the basis of the obtained PET information, any additional test other than the pre-fixed screening program was not considered to be a “combined screening test.” If a cancer screening test was performed using a PET/CT scanner, regardless of the method used or manner of interpretation, the information obtained from the CT integrated in the PET/CT scanner was not regarded as a combined screening test, but as PET/CT itself. This was because the CT findings could not be ignored when using PET/CT. Hence “PET positive” is defined as positive findings on PET or PET/CT. Accordingly, the cases with PET/negative and CT/positive findings on screening tests performed by PET/CT were defined as “PET/positive”.

“Required further examination” is defined as cases for which a thorough examination was recommended on the basis of the comprehensive results of FDG-PET and/or any combined screening tests. Cases for which reexamination was recommended are not included in “required further examination.” “Obtained result of further examination” is defined as being clearly categorized as “proved cancer,” “excluded cancer,” or “strict follow-up because of disproved cancer” through the results of additional examinations and treatment.

Statistical analysis

The Chi-square test for independence was performed to compare the detection rate, sensitivity, and positive predictive value between PET and PET-CT. A P value of less than 0.05 was considered to be statistically significant.

Results

Characteristics of subjects who underwent FDG-PET cancer screening

The number of subjects in each age group is listed in Table 2. Subjects in their 50s and 60s made up the majority, accounting for 63.8 % of all subjects. The rate of repeated annual FDG-PET cancer screening was 26.4 % for all subjects.

Table 2.

Number of subjects who underwent FDG-PET cancer screening program

Age group Number Rate (%) Male Rate (%) Female Rate (%)
10–19 29 0.02 10 0.01 19 0.03
20–29 1,008 0.7 474 0.5 534 0.9
30–39 8,923 5.7 5,073 5.5 3,850 6.2
40–49 26,206 16.9 15,764 17.0 10,442 16.8
50–59 51,546 33.2 30,615 33.0 20,931 33.7
60–69 47,712 30.7 29,382 31.7 18,330 29.5
70–79 16,854 10.8 9,931 10.7 6,923 11.2
80- 2,534 1.6 1,490 1.6 1,044 1.7
Unknown 644 0.4
Total 155,456 92,739 62,073

A PET/CT scanner was used in 95,046 cases (61.1 %), and a dedicated PET scanner in 60,410 (38.9 %). In 2006, the number of different scanners used in the FDG-PET screening program was almost the same (dedicated PET scanner: 21,524 cases, PET/CT scanner: 21,527 cases). After 2007, the use of PET/CT scanners was higher than PET (in 2007: dedicated PET scanner: 15,217 cases, PET/CT scanner: 24,650 cases; in 2008: dedicated PET scanner: 12,037 cases, PET/CT scanner: 26,892 cases, and in 2009: dedicated PET scanner: 11,629 cases, PET/CT scanner: 21,970 cases).

FDG-PET method

The FDG-PET scanning method was analyzed in 109 facilities with 171 scanners consisting of 44 PET scanners and 127 PET/CT scanners. Injected radioactivity of FDG was consistent in 38 facilities (range 111–370 MBq; average 188.2 MBq), and variable in 71 facilities. The facilities with variable injected radioactivities of FDG used 3.61 MBq per kilogram body weight on average (range 2.6–5.0 MBq/kg), with total radioactivity of 216.9 MBq on average (range 156–300 MBq) if used in subjects 165 cm tall and weighing 60 kg. Maximum injected radioactivity of FDG ranged widely from 210 to 518 MBq (average 338.4 MBq). Attenuation correction was performed in 108 facilities. All the attenuation correction with PET scanners was performed by conventional transmission scanning, and all the attenuation correction of PET/CT cameras was performed by CT scanning.

The start time of the emission scan was most frequently 60 min after injection of FDG (average 60.1 min). Total required scanning time (including the scanning time of CT and transmission scan) was 25.5 min on average. The scanned range was most frequently “parietal to knee” regardless of whether a PET scanner or PET/CT scanner was used. Delayed scanning was performed regularly at 28 facilities, if necessary at 67, and never at 22 facilities (8 facilities had multiple answers, and the decision depended on the scanner type used). The start time of delayed scanning was frequently 120 min after injection of FDG (average 117.9 min).

Characteristics of CT scanners integrated in the PET/CT systems

The majority of PET centers used variable “mAs” values rather than a consistent mAs value (the product of X-ray tube current and exposure time) fixed to CT scanners integrated in the PET/CT system. Although the displayed CT scanning parameters on the machines and their definitions differ according to the manufacturer, the average displayed tube current (mAs), pitch, and computed tomography dose index-volume (CTDIvol) (mGy) of the scanner in facilities that applied a consistent mAs value to CT scanning were 95.2 mAs, 1.27, and 6.2 mGy, respectively, whereas in facilities applying variable mAs values, they were 114.2 mAs (maximum mAs value), 1.47 and 6.3 mGy, respectively. Tube voltage (kV) was most frequently 120 or 140 kV.

The CT image reconstruction interval was most frequently 3.75 or 5 mm. The location of the hands at the time of PET/CT scanning was elevated and pulled down at equal frequencies, and CT images were most frequently obtained during resting breathing.

Combined screening tests

The combined screening tests in the various facilities are listed in Table 3. A total of 85.5 % of all facilities performed one or more combined screening tests in addition to FDG-PET. The number and type of combined screening tests differed by facility and by individual subjects even in the same facility. CT, abdominal ultrasonography (US), pelvic magnetic resonance imaging (MRI), fecal occult blood test (FOBT), and several kinds of serum tumor marker tests were most frequently adopted as combined screening tests with PET examination. On the other hand, physically taxing screening methods for the GI tract and colon tended to be avoided.

Table 3.

Combined screening tests and rate (%) of PET centers performing each test

Modalities Rate (%) Modalities Rate (%)
Brain MRI 39.1 Cervical cytology 16.6
Otolaryngologic examination 0.6 Pelvic ultrasonography 19.1
Head and neck CT 27.1 Pelvic CT 32.3
Head and neck MRI 1.8 Pelvic MRI 48.1
Thyroid ultrasonography 37.4 Prostate ultrasonography 26.6
Inspection and palpation of breast 8.1 Prostate MRI 44.2
Breast ultrasonography 27.9 Prostate specific antigen (PSA) 82.2
Mammography 17.5 Carcinoembryonic antigen (CEA) 76.6
Sputum cytology 10.6 Cancer antigen 19-9 (CA19-9) 68.1
Chest X-ray 11.7 Cancer antigen 125 (CA125) 32.6
Chest CT 57.5 α-fetoproteins (AFP) 60.5
Gastric fluoroscopy 2.6 Pepsinogen 41.0
Gastric endoscopy 14.4 Squamous cell carcinoma antigen (SCC) 47.9
Helicobacter pylori infection test 11.9 Cytokeratin-19 fragment (CYFRA) 22.8
Abdominal ultrasonography 57.4 Pro-gastrin releasing peptide (Pro-GRP) 15.8
Abdominal CT 37.1 Cancer antigen 15-3 (CA15-3) 2.5
Abdominal MRI 15.8 Neuron specific enolase (NSE) 4.6
Fecal occult blood test (FOBT) 71.7 Thyroglobulin 11.3
Barium enema 0.0 PIVKA-II 7.5
Colonoscopy 1.9 Urinary test 13.8

Characteristics of subjects with positive findings suggesting possible cancer

The number, gender, and age of subjects with positive findings suggesting possible cancer are listed in Table 4. Positive findings were noted in 16,955 cases (9,505 men, 7,352 women, and 98 gender unidentified). The rate of suspected cancer was 10.9 % (annual yearly range 10.3–11.6 %) in total, which increased with age. The rate of suspected cancer in women was high in subjects aged 30–59 years due to the increased number of suspected thyroid and breast cancers.

Table 4.

Number of subjects who were positive by screening FDG-PET and/or one or more of the combined screening tests if any

Age group Number Rate (%) Male Rate (%) Female Rate (%)
10–19 0 0.0 0 0.0 0 0.0
20–29 55 5.5 13 2.7 42 7.9
30–39 653 7.3 285 5.6 368 9.6
40–49 2,194 8.4 1,027 6.5 1,167 11.2
50–59 5,240 10.2 2,900 9.5 2,340 11.2
60–69 5,876 12.3 3,592 12.2 2,284 12.5
70–79 2,437 14.5 1,427 14.4 1,010 14.6
80- 402 15.9 261 17.5 141 13.5
Unknown 98 15.2
Total 16,955 10.9 9,505 10.2 7,352 11.8

The rate of suspected cancer was 9.8 % (range 9.3–10.8 %) for dedicated PET combined with other screening examinations, lower than the rate of 11.6 % (range 10.7–12.0 %), which was found for PET/CT combined with other screening examinations (P < 0.01).

Analysis of suspected cancer according to the interpretation by FDG-PET and/or combined screening examination

Of the 16,955 cases with suspected cancer, the interpretation in 16,272 cases depended on the PET and combined screening test. Both PET positive and combined screening test positive were 20.4 %, PET positive only was 32.1 %, and combined screening test positive only was 47.5 %. Both dedicated PET and combined screening test positive were 23.1 %, dedicated PET positive only was 27.5 % and combined screening test positive only was 49.4 %. Both PET/CT positive and combined screening test positive were 18.9 %, PET/CT scanner positive only was 34.6 %, and combined screening test positive only was 46.5 %. As a result, the estimated rate of suspected cancer was 5.0 % with dedicated PET, 6.2 % with PET/CT, and 7.4 % with the combined screening tests (Fig. 1). The FDG-PET-positive rate was slightly higher in screening tests performed using PET/CT scanners than PET scanners (P < 0.01), and the positive rate with combined screening tests was much higher than FDG-PET (P < 0.01).

Fig. 1.

Fig. 1

Estimated rates of suspected cancer by FDG-PET and combined screening examination are shown. Of the 16,272 cases of suspected cancer by FDG-PET cancer screening program, 5,811 cases were suspected by dedicated PET and 10,461 cases by PET/CT. According to this survey, the cancer suspected rate was 9.8 % for dedicated PET combined with other screening examinations and 11.6 % for PET/CT combined with other screening examinations. The estimated number receiving FDG-PET cancer screening program was 59,296 for dedicated PET combined with other screening examinations and 90,181 for PET/CT combined with other screening examinations. Finally, the total number of subjects who received FDG-PET cancer screening program was estimated to be 149, 477

Analysis of detected cancers

Of the 16,955 cases with suspected cancer, final results were obtained from 7,197 cases (42.4 %). The number of detected cancer cases was 1,912, which amounted to 1.23 % of the total number of cases screened. The number, gender, and age of the subjects in whom cancer was detected are listed in Table 5, and the number and kind of found cancers are listed in Table 6. Of the 1,912 cases of detected cancer, 1,491 had positive findings on PET (including PET/CT) amounting to 0.96 % of the total screening number. As a result, 78.0 % of detected cancers had positive PET findings. Of the 1,491 cases, 492 were detected by screening tests performed with PET scanners, and 999 cancers by screening tests performed with PET/CT scanners. The detection rate of cancer was higher with PET/CT scanner at 1.05 % (999/95,039) than with PET scanner at 0.81 % (492/60,407) (P < 0.01). Of the 999 cancers detected by PET/CT scanners, 278 cases were positive only by PET, 594 cases were positive by PET and CT integrated with PET/CT and 127 cases were positive only by CT integrated in PET/CT.

Table 5.

Number and rate of found cancers which was positive by screening FDG-PET and/or one or more of the combined screening tests if any

Age group Total Male Female
Number Found cancer PPV (%) Number Found cancer PPV (%) Number Found cancer PPV (%)
10–19 0 0 0 0 0 0 0 0 0
20–29 14 0 0 3 0 0.0 11 0 0
30–39 218 36 16.5 83 12 14.5 135 24 17.8
40–49 868 199 22.9 355 71 20.0 513 128 25.0
50–59 2,282 549 24.1 1,196 282 23.6 1,086 267 24.6
60–69 2,593 711 27.4 1,553 468 30.1 1,040 243 23.4
70–79 1,063 352 33.1 632 230 36.4 431 122 28.3
80- 159 65 40.9 103 45 43.7 56 20 35.7
Total 7,197 1,912 26.6 3,925 1,108 28.2 3,272 804 24.6

PPV positive predictive value

Table 6.

Number of cancers detected by the screening program

Disease Number Disease Number
Colorectal cancer 396 Thymic tumor 8
Thyroid cancer 353 Bile duct cancer 6
Lung cancer 319 Gallbladder cancer 5
Prostate cancer 165 Sarcoma 5
Breast cancer 163 Testicular cancer 4
Gastric cancer 124 Small intense tumor 4
Renal cancer 59 Primary unknown cancer 4
Malignant lymphoma 53 Gastrointestinal stromal tumor (GIST) 3
Pancreas cancer 45 Brain tumor 3
Esophagus cancer 38 Metastatic bone tumor 3
Uterine cancer 35 Pleural tumor 2
Bladder cancer 30 Peritoneal cancer 1
Liver cancer 27 Adrenal cancer 1
Head and neck cancer 22 Urethra cancer 1
Ovarian cancer 21 Urachal tumor 1
Bone marrow disease 10 Skin cancer 1
Total 1,912

According to the results of further examinations, the true positive rate for subjects with suggested possible cancer (positive predictive value) was 32.3 % (1,491/4,609) with PET, with no statistically significant difference noted between PET/CT at 32.6 % (1,000/3,069) and PET at 31.9 % (491/1,540). Of the 7,197 cases in which a final result was obtained, repeated annual FDG-PET cancer screening tests were performed in 1,240 cases, with cancer found in 22.9 % of them, lower than that in the unrepeated cases (27.5 %).

The cancers found in the FDG-PET cancer screening program were of a wide variety, as listed in Table 6. The most frequently detected cancers with high PET-positive rates were colon/rectum cancer (396 cases, 85.9 %), thyroid cancer (353 cases, 90.7 %), lung cancer (319 cases, 86.8 %), and breast cancer (163 cases, 84.0 %). Low PET-positive rates, but high positive rates in combined screening tests were found with prostate cancer (165 cases, 37.0 %) and gastric cancer (124 cases, 37.9 %). Renal cancer, malignant lymphoma, pancreas cancer, esophagus cancer, uterine cancer, and bladder cancer were also frequently found. Cancers were most frequently found in the age groups of 50–59 years and 60–69 years, accounting for 66.9 % of the total found cancers. Cancers were most frequently found in the age group of 60–69 years in men and 50–59 years in women.

Clinical stage for six representative kinds of cancers

Table 7 summarizes the result of PET according to Union for International Cancer Control (UICC) clinical stage for six representative kinds of cancers (lung, colon/rectum, thyroid, breast, prostate and stomach). Cancer of the lung, colon/rectum, thyroid and breast was found mostly at Stage I with high PET sensitivity. Most prostate and gastric cancers were also categorized as Stage I, but they were largely found with the combined screening tests. The cancers found with repeated FDG-PET cancer screening were commonly found at Stage I, but a small number of cancers were found in advanced stages.

Table 7.

PET-positive rate and number of found cancer according to UICC Stage

UICC Stage Kind of cancer
Lung Colon Breast Thyroid Prostate Stomach
FDG-PET screening program 0 76.7 (33/43) 81.9 (9/11)
I 84.2 (117/139) 85.3 (93/109) 82.1 (55/67) 99.0 (95/96) 25.0 (8/32) 8.8 (3/31)
II 100.0 (6/6) 77.8 (7/9) 91.6 (11/12) 100.0 (9/9) 33.3 (2/6) 75.0 (3/4)
III 100.0 (26/26) 100.0 (21/21) 100.0 (1/1) 90.0 (9/10) 25.0 (2/8) 100.0 (5/5)
IV 100.0 (23/23) 100.0 (20/20) 100.0 (5/5) 100.0 (7/7) 80.0 (4/5) 100.0 (7/7)
Repeated FDG-PET cancer program 0 50.0 (1/2) 50.0 (1/2)
I 80.6 (25/31) 88.9 (8/9) 57.1 (8/14) 100.0(4/4) 33.3 (2/6) 22.2 (2/9)
II 100.0 (1/1)
III 100.0 (1/1) 100.0 (2/2) 100.0 (1/1)
IV 100.0 (2/2) 100.0 (1/1) 100.0 (1/1) 100.0 (2/2)

Numbers in parentheses represent number of PET-positive case/number of total screened cancer

UICC The Union for International Cancer Control

Analysis of detected non-cancerous lesions

According to the results of further examinations for subject with positive findings in FDG-PET screening program, many non-cancerous lesions were found. The major non-cancerous lesions found are listed in Table 8. Most of the non-cancerous lesions were found with PET or PET/CT. However, FDG-PET or PET/CT had moderate to low sensitivity for colonic diverticulum (45.7 %), benign prostatic hypertrophy (35.1 %), liver hemangioma (28.6 %), mammary cyst (27.6 %) and gastric polyp (7.3 %), which tended to be found with the combined screening tests.

Table 8.

Number of benign lesions detected by the screening program

Disease Number Disease Number
Colonic adenoma (polyp) 687 Gastric polyp 41
Nodular goiter 457 Uterine myoma 40
Benign prostate hypertrophy 114 Benign parotid tumor 30
Old inflammatory change of lung 113 Mammary cyst 29
Inflammatory change of lung 99 Liver hemangioma 28
Colonic diverticulum 92 Thyroid cyst 27
Chronic thyroiditis 90 Ovarian cyst 19
Colitis 66 Neurogenic tumor 19
Mastopathy 65 Endometriosis 14
Hemorrhoid 64 Sarcoidosis 14
Follicular goiter 46 Tuberculosis 10
Mammary fibroadenoma 45 Adenoid 10

Discussion

There have been many arguments regarding the application of FDG-PET for cancer screening [1, 46]. PET examination has the potential to detect many types of malignant neoplasms; therefore, cancer screening with PET is expected to detect malignant neoplasms throughout the body. However, it is well known that PET has limited detectability for several types of malignant neoplasms due to their small size, low glucose metabolism, and high physiological background FDG uptake. As a result, researchers involved in cancer screening using FDG-PET share a common understanding that cancer screening using PET or PET/CT must be established as a program in combination with several other modalities to compensate for what is not apparent with PET and PET/CT [2, 3, 5, 6]. The Japanese Society of Nuclear Medicine published guidelines for “FDG-PET cancer screening”, which include details about common examinations adopted in Japan that have the potential to contribute to an increased cancer detection rate. These guidelines facilitate uniform and accurate PET cancer screening at many PET centers, but do not advocate any particular screening methods to be combined with PET examination. Therefore, PET centers modify their cancer screening programs depending on their circumstances (even though they share some common ground, as shown in the present report). The suspected cancer detection rate with combined screening tests is much higher than that of FDG-PET; thus, adoption of a common combined screening test and improvement in accuracy will contribute to increasing the specificity of the FDG-PET cancer screening program. The rate of suspected cancer was higher in PET/CT combined with other screening examinations than dedicated PET combined with other screening examinations. From the result of suspected cancer according to the interpretation of FDG-PET and/or combined screening examinations, the estimated rate of suspected cancer was higher with PET/CT than PET. As a result, PET/CT increased the rate of suspected cancer, but this was not associated with any specific type of cancer.

The age-specific incidence of cancer shows a sudden rise after 60 years of age in Japan based on the report from the Foundation for Promotion of Cancer Research (FPCR) [7]. The number of FDG-PET cancer screening programs is highest for subjects aged 50–59 years (33.2 % of all subjects), and the incidence of cancer increases with age. Subjects receiving FDG-PET cancer screening are younger than the reported age groups with the most frequent incidence of cancer. The number of malignant neoplasms found by the FDG-PET cancer screening program is higher than the age-matched annual incidence of cancer in Japan. The distinctive feature of FDG-PET cancer screening is that it can detect various kinds of cancers, including cancers with unestablished organized screening methodologies. Moreover, the majority of found cancers were of Stage I, with expected good prognoses with existing treatment methods. The incidence of cancer in this survey is similar to those in several reports from single or multicenter facilities [3, 5, 813], indicating that PET cancer screening is conducted with a considerable level of consistency throughout Japan. Detection rates with FDG-PET cancer screening are higher than the total detection rates of other cancer screening modalities performed in Japan (such as chest radiography and sputum cytology, mammography with inspection and palpation of breast, upper gastrointestinal fluoroscopy, FOBT, and uterine cervical cytology), which have already proven cancer screening efficacy [14]. Terauchi et al. [14] reported strict limitations of FDG-PET for cancer screening based on data from the Research Center for Cancer Prevention and Screening (RCCPS) and National Cancer Center in Japan, which were particularly notable in screening for colon cancer, lung cancer and gastric cancer. All found lung cancers were categorized as Stage I, and most found colon cancers were localized in the intramucosal layer. The results of the present report indicate that cancer screening by PET examination alone was limited to small and/or early cancers; therefore, combined examinations to detect cancers missed by FDG-PET is mandatory. On the other hand, combined examinations are associated with an increased number of false positives, and can lead to an increase in unnecessary further examinations and follow-up. Combined screening tests must be specific for a particular cancer. FDG-PET cancer screening is not a completely established method for cancer screening. FDG-PET cancer screening should be used with a sufficient explanation and adequate understanding of its advantages, disadvantages and limitations.

One problem is the appropriate time interval for conducting FDG-PET cancer screening. The present results show that cancer was found in 22.9 % of suspected cancer cases in which repeated annual FDG-PET cancer screening tests were performed. Although most cancers found in the repeated annual FDG-PET cancer screening tests were Stage I, the cancer detection rate was not low. Estimated from the data of the HIMEDIC Imaging Center at Lake Yamanaka, cancer was found in 1.58 % of cases at the first screening, and in 1.18 % of cases at the second screening, but only in 0.69 % of cases in the third screening. The detection rate was estimated to decrease in PET examinations, but was stable in the combined screening test at a rate of approximately 0.2 % [2]. The present results showed that cancer at Stage I was frequently found by FDG-PET cancer screening, with a high sensitivity of FDG-PET for both the first and repeated examinations. These results highlight the limitation of a one-time FDG-PET cancer screening program, and that two consecutive screenings followed by a combined screening test may be able to detect more malignancies. Among subjects who underwent a repeated FDG-PET cancer screening program, Stage III and IV cancers comprised 11.4 % of the found cancers. Found cancers in a repeated FDG-PET screening program may be interpreted as negative on the first time examination or show a rapid onset within 1 year. It is absolutely clear that the FDG-PET cancer screening program cannot detect all malignancies.

The main issue for FDG-PET cancer screening will be how it can detect various cancers and reduce their mortality rate. FDG-PET cancer screening detected many prostate cancers and thyroid cancers, which are associated with relatively long survival times. In contrast, FDG-PET cancer screening programs detected pancreas cancer at an early clinical stage [15], but the high mortality rate of even early-stage pancreas cancer means that the FDG-PET cancer screening program may be non-contributory for this tumor. Although a randomized control study is a maximally efficient method for showing the benefit of FDG-PET cancer screening, it requires a long observation time and a large population. The United States Preventive Services Task Force (USPSTF) advocated an “analytic framework” consisting of chain logic of evidence supporting a connection between the preventive service and improved health outcomes [16]. As a result, the value of FDG-PET cancer screening might be indirectly estimated by detailed analysis of found cancers compared to the known epidemiological trend of cancer. Moreover, decision modeling analysis may also have the potential to clarify the clinical benefit of a PET cancer screening program [17], even though direct evidence such as reduction of mortality is essential.

Radiation exposure is a major problem in FDG-PET cancer screening. According to the International Commission on Radiation Protection (ICRP), the estimated cancer incidence induced by radiation exposure was 0.0048 % per mSv [13]. Murano et al. reported that the average effective dose of radiation exposure in a PET center is estimated to be 4.4 mSv with a dedicated PET study and 14.2 mSv with a PET/CT study. The average radiation exposure associated with FDG-PET cancer screening will increase because of the increasing availability of PET/CT scanners. Risk–benefit analysis has shown that FDG-PET cancer screening is beneficial for examinees above the break-even ages based on a Japanese nationwide survey. However, that survey mentioned that the risks and benefits of radiation exposure must be explained to examinees because of the larger radiation dose used in cancer FDG-PET screening compared with other radiological tests [18].

The high cost of an FDG-PET cancer screening program is another huge problem. Effective combined screening tests, at the minimum, for compensating for FDG-PET should be selected as a screening program, which can lead to a lower cost and burden on the recipients of such screening. Although the cost of FDG-PET in Japan is lower than that in the United States ($1,000 vs. $2,000, respectively) [1, 19], it is still far higher than that of a screening examination covered by health insurance plans. Therefore, cost effectiveness is not expected in an FDG-PET cancer screening program. If maximum cost effectiveness is required for an FDG-PET cancer screening program, the program should target a group at high risk for a cancer that is commonly detected by PET and PET/CT. Otherwise, the value of a FDG-PET cancer screening program is left to the judgment of the individual provided that the advantages, disadvantages and limitations of FDG-PET for cancer screening are fully disclosed.

Beside malignancies, many benign lesions were found with the FDG-PET cancer screening program. They are regarded as false positive cases. However, colonic adenoma has the potential for malignant transformation [20, 21], and screening and removal of adenomatous polyps are significant aspects of prevention and improvement of prognosis. The clinical importance of screening for adenomas is to detect advanced adenomas (defined as larger adenomas with a diameter of 10 mm or more). The sensitivity of FDG-PET for detecting adenomas depends on their size and histologic grade [22, 23]. Thus, FDG-PET has a high potential of detecting adenomas that should be removed and suggesting the need for further examinations such as colonoscopy. Moreover, some non-malignant diseases (such as tuberculosis, inflammatory changes of the lung, and sarcoidosis) are also clinically important, and in some instances, early detection may enhance the quality of life and longevity. Therefore, FDG-PET screening may provide an opportunity to favorably alter the prognosis in various cases.

A limitation of this survey is inadequate investigation of subjects who were judged to be negative in the FDG-PET cancer screening program. Also, the present survey received inadequate answers from subjects who were judged as having possible malignancy by the FDG-PET cancer screening program, even though proven malignancies appeared to be obtained more frequently.

Conclusion

The FDG-PET screening program in Japan has detected a variety of cancers at an early stage. However, several cancers were found in repeated FDG-PET cancer screening program, indicating an important limitation of a one-time FDG-PET cancer screening program. The value of the FDG-PET cancer screening program is left to the judgment of individuals with regard to its potentials and limitations.

Acknowledgments

This work was supported by the National Cancer Center Research and Development Fund 23-A-25, Japanese Council of PET Imaging: working group on epidemiology study for PET cancer screening, the PET cancer screening research group of "Yokohama City University". The authors would like to express our sincere appreciation and gratitude for Sachiko Yanagida from Japan Radioisotope Association for management of this survey and data, and Yoshihide Nakamura from Japan Radioisotope Association for management of this survey.

Conflict of interest

The authors declare no conflict of interest.

References

  • 1.Schöder H, Gönen M. Screening for cancer with PET and PET/CT: potential and limitations. J Nucl Med. 2007;48(Suppl 1):4S–18S. [PubMed] [Google Scholar]
  • 2.Ide M. Cancer screening with FDG-PET. Q J Nucl Med Mol Imaging. 2006;50:23–27. [PubMed] [Google Scholar]
  • 3.Minamimoto R, Senda M, Uno K, Jinnouchi S, Iinuma T, Ito K, et al. Performance profile of FDG-PET and PET/CT for cancer screening on the basis of a Japanese Nationwide Survey. Ann Nucl Med. 2007;21:481–498. doi: 10.1007/s12149-007-0061-8. [DOI] [PubMed] [Google Scholar]
  • 4.Weckesser M, Schober O. Is whole-body FDG-PET valuable for health screening? Against. Eur J Nucl Med Mol Imaging. 2005;32:342–343. doi: 10.1007/s00259-005-1775-2. [DOI] [PubMed] [Google Scholar]
  • 5.Ide M, Suzuki Y. Is whole-body FDG-PET valuable for health screening? For. Eur J Nucl Med Mol Imaging. 2005;32:339–341. doi: 10.1007/s00259-005-1774-3. [DOI] [PubMed] [Google Scholar]
  • 6.Yasuda S, Ide M, Fujii H, Nakahara T, Mochizuki Y, Takahashi W, et al. Application of positron emission tomography imaging to cancer screening. Br J Cancer. 2000;83:1607–1611. doi: 10.1054/bjoc.2000.1496. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.The Foundation for Promotion of Cancer Research (FPCR) Cancer Statistics in Japan 2010 http://ganjoho.jp/public/statistics/backnumber/2010_en.html.
  • 8.Ono K, Ochiai R, Yoshida T, Kitagawa M, Omagari J, Kobayashi H, et al. The detection rates and tumor clinical/pathological stages of whole-body FDG-PET cancer screening. Ann Nucl Med. 2007;21:65–72. doi: 10.1007/BF03034001. [DOI] [PubMed] [Google Scholar]
  • 9.Kojima S, Zhou B, Teramukai S, Hara A, Kosaka N, Matsuo Y, et al. Cancer screening of healthy volunteers using whole-body F-18 FDG-PET scans: the Nishidai clinic study. Eur J Cancer. 2007;43:1842–1848. doi: 10.1016/j.ejca.2007.05.010. [DOI] [PubMed] [Google Scholar]
  • 10.Nishizawa S, Kojima S, Teramukai S, Inubushi M, Kodama H, Maeda Y, et al. Prospective evaluation of whole-body cancer screening with multiple modalities including [18F]fluorodeoxyglucose positron emission tomography in a healthy population: a preliminary report. J Clin Oncol. 2009;27:1767–1773. doi: 10.1200/JCO.2008.18.2238. [DOI] [PubMed] [Google Scholar]
  • 11.Chen YK, Ding HJ, Su CT, Shen YY, Chen LK, Liao AC, et al. Application of PET and PET/CT imaging for cancer screening. Anticancer Res. 2004;24:4103–4108. [PubMed] [Google Scholar]
  • 12.Ko DH, Choi JY, Song Y, Lee SJ, Kim YH, Lee K, et al. The usefulness of 18F-FDG PET as a cancer screening test. Nucl Med Mol Imaging. 2008;42:444–450. [Google Scholar]
  • 13.Lee JW, Kang KW, Paeng JC, Lee SM, Jang SJ, Chung JK, et al. Cancer screening using 18F-FDG PET/CT in Korean asymptomatic volunteers: a preliminary report. Ann Nucl Med. 2009;23:685–691. doi: 10.1007/s12149-009-0291-z. [DOI] [PubMed] [Google Scholar]
  • 14.Terauchi T, Murano T, Daisaki H, Kanou D, Shoda H, Kakinuma R, et al. Evaluation of whole-body cancer screening using 18F–2-deoxy-2-fluoro-d-glucose positron emission tomography: a preliminary report. Ann Nucl Med. 2008;22:379–385. doi: 10.1007/s12149-008-0130-7. [DOI] [PubMed] [Google Scholar]
  • 15.Minamimoto R, Senda M, Terauchi T, Jinnouchi S, Inoue T, Iinuma T, et al. Analysis of various malignant neoplasms detected by FDG-PET cancer screening program: based on a Japanese Nationwide Survey. Ann Nucl Med. 2011;25:45–54. doi: 10.1007/s12149-010-0428-0. [DOI] [PubMed] [Google Scholar]
  • 16.Harris RP, Helfand M, Woolf SH, Lohr KN, Mulrow CD, Teutch SM, et al. Current methods of the US Preventive Services Task Force: a review of the process. Am J Prev Med. 2001;20:21–35. doi: 10.1016/S0749-3797(01)00261-6. [DOI] [PubMed] [Google Scholar]
  • 17.Vach W, Flemming P, Hoilund-Carlsen PF, Gerke O, et al. Generating evidence for clinical benefit of PET/CT in diagnosing cancer patients. J Nucl Med. 2011;52:77S–85S. doi: 10.2967/jnumed.110.085704. [DOI] [PubMed] [Google Scholar]
  • 18.Murano T, Minamimoto R, Senda M, Uno K, Jinnouchi S, Fukuda H, et al. Radiation exposure and risk-benefit analysis in cancer screening using FDG-PET: results of a Japanese nationwide survey. Ann Nucl Med. 2011;25:657–666. doi: 10.1007/s12149-011-0511-1. [DOI] [PubMed] [Google Scholar]
  • 19.Yasunaga H. Who wants cancer screening with PET? A contingent valuation survey in Japan. Eur J Radiol. 2009;70:190–194. doi: 10.1016/j.ejrad.2007.11.020. [DOI] [PubMed] [Google Scholar]
  • 20.Bond JH. Polyp guideline: diagnosis, treatment, and surveillance for patients with colorectal polyps. Practice Parameters Committee of the American College of Gastroenterology. Am J Gastroenterol. 2000;95:3053–3063. doi: 10.1111/j.1572-0241.2000.03434.x. [DOI] [PubMed] [Google Scholar]
  • 21.Chen CD, Yen MF, Wang WM, Wong JM, Chen TH. A case-cohort study for the disease natural history of adenomacarcinoma and de novo carcinoma and surveillance of colon and rectum after polypectomy: implication for efficacy of colonoscopy. Br J Cancer. 2003;88:1866–1873. doi: 10.1038/sj.bjc.6601007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Prabhakar HB, Sahani DV, Fischman AJ, Mueller PR, Blake MA. Bowel hot spots at PET-CT. Radiographics. 2007;27:145–159. doi: 10.1148/rg.271065080. [DOI] [PubMed] [Google Scholar]
  • 23.Nakajo M, Jinnouchi S, Tashiro Y, Shirahama H, Sato E, Koriyama C, et al. Effect of clinicopathologic factors on visibility of colorectal polyps with FDG PET. AJR Am J Roentgenol. 2009;192:754–760. doi: 10.2214/AJR.08.1304. [DOI] [PubMed] [Google Scholar]

Articles from Annals of Nuclear Medicine are provided here courtesy of Springer

RESOURCES