Abstract
Optical and magnetic tweezers are widely employed to probe the mechanics and activity of individual biomolecular complexes. They rely on micrometer-sized particles to detect molecular conformational changes from the particle position. Real-time particle tracking with Ångström accuracy has so far been only achieved using laser detection through photodiodes. Here we demonstrate that camera-based imaging can provide a similar performance for all three dimensions. Particle imaging at kHz rates is combined with real-time data processing being accelerated by a graphics processing unit. For particles that are fixed in the sample cell we can detect 3 Å sized steps that are introduced by cell translations at rates of 10 Hz, while for DNA-tethered particles 5 Å steps at 1 Hz can be resolved. Moreover, 20 particles can be tracked in parallel with comparable accuracy. Our approach provides a simple and robust way for high-resolution tweezers experiments using multiple particles at a time.
In the recent years optical and magnetic tweezers have been applied to study a large variety of biological and non-biological micro-scale systems1-6. These techniques allow to exert force on an individual object and to read out simultaneously its conformational change along the force direction. For both force transduction as well as conformational probing micro-meter sized beads are used. The position of the bead reports the length changes of the system investigated. It was possible to push the limits of the particle position tracking such that fundamental step sizes of biological motors could be resolved, e.g. the 8 nm steps of the cytoskeleton motor kinesin7 and even single base pair steps (3.4 Å) of DNA based motors8-10. This provides unprecedented insight into smallest conformational changes of biomolecular systems. Such high-resolution measurements have so far only been reported for optical tweezers, where the trapping laser itself is used for displacement detection through quadrant photo diodes or position sensitive devices8,10,11. The main advantage of the laser based particle tracking is the excess amount of photons available when typically using trapping powers at the order of 1 W (corresponding to ~1019 photons per second). Thus, shot noise at the detector is not limiting at the relevant sub-second time scale if the forward scattered light is analyzed. This contrasts imaging based tracking, where the two- or three-dimensional (2D or 3D) position of particles is inferred from camera images12-14. Considering an image size of 100 pixels ×100 pixels and a pixel well depth of about 10,000 electrons, only 1010 photons would be evaluated when tracking at 100 Hz frame rate even for optimal light conditions. In practice, camera based tracking is indeed severely limited by shot-noise and is therefore typically considered as tracking with low spatial and temporal resolution15. However, high-resolution camera-based tracking is potentially much simpler to realize and may provide even higher stability. It requires neither a large optical setup scheme nor highly stable lasers and laser deflection units10,11. Instead it relies only on the actual camera combined with standard wide-field illumination. Furthermore, it can easily be adapted to track many particles in parallel16-18.
Here we intend to push the limits of camera-based particle tracking by maximizing the number of photons evaluated in order to reduce the shot noise limitation. For this we unify different attempts within our real-time particle tracking scheme. To maximize photon numbers per image we use a large magnification for particle imaging14. In order to increase photon numbers per time even further, we perform high-speed imaging using a CMOS camera, for which real-time tracking in 2D at kHz rates has been previously demonstrated19-21. Our goal to maxize the imaging throughput requires however to cope with the massive amount of data from high-speed imaging as well as the more elaborate 3D position tracking. To this end we use real-time data processing in a graphics processing unit (GPU), which was previously employed to speed up post-processing of image packages acquired at >10 kHz 22. Combining these approaches allows us to resolve base-pair sized movements of microbeads on a sub-second time scale as well as the parallel tracking of tens of beads at a time. Our real-time data analysis supports long-term data recording at highest temporal and spatial resolution. Furthermore it allows in situ control and manipulation of tethered objects.
Results
Particle tracking scheme
The particle tracking setup is based on a homebuilt inverted microscope (Fig. 1) designed for high mechanical stability. The fluidic sample cell contains fixed polystyrene beads that are firmly attached to the bottom of the cell as well as DNA tethered magnetic beads. A pair of magnets that is placed on a motorized stage above the cell allows application of pulling forces onto the DNA. The sample cell is mounted onto a 3D nanopositiong stage to induce well determined bead displacements through cell translations. Particle images are projected through the microscope objective onto a high-speed CMOS camera that allows real-time streaming of images with 1280 pixels ×1024 pixels at 500 Hz to the connected computer. When streaming smaller regions of interest (ROIs) instead of the full frame, the maximum rate grows inversely proportional to the number of pixels considered. Tracking of particle positions is carried out either in high-resolution mode supporting tracking of up to four particles in parallel with high spatial resolution at kHz rates or in multi-bead mode supporting tracking of tens of particles with moderate spatial resolution at rates of up to 500 Hz.
Figure 1. Scheme of the particle tracking setup and the image analysis routine.
Spherical particles within a fluidic cell are mounted onto the sample stage of a homebuilt microscope. The latter comprises a piezo-actuated nanopositiong stage allowing for sample displacements in all three dimensions with Ǻngström precision. A pair of magnets above the fluidic cell is used to exert forces onto DNA tethered magnetic beads. Tracking of the particle positions is carried out either in high-resolution mode supporting tracking of up to four particles in parallel at high spatial resolution and kHz rates or in multi-bead mode supporting tracking of tens of particles at moderate spatial resolution and rates up to 500 Hz. For high-resolution tracking the sample is illuminated using a fiber-coupled mercury lamp. Bead images are acquired simultaneously from distant regions of interests (ROIs) by a CMOS camera. Image processing (see red arrows) is carried out in parallel within the central processing unit (CPU) regarding x,y and z position calculations as well as the graphics processing unit (GPU) regarding radial intensity profile calculations. The red squares in the high resolution sample image indicate the 160 pixels ×160 pixels ROIs that are streamed from the camera into CPU and GPU. For multi-bead tracking the sample is illuminated with a 625 nm LED. Full frame images are streamed into the GPU where also all image processing is carried out (see gray arrows). The red square in the multi-bead sample image corresponds to the size of the 72 pixels ×72 pixels ROIs that are used for tracking. The size of the shown sample image regions is 308 pixels ×224 pixels.
For the high-resolution tracking a large magnification with a conversion factor of 63 nm/pixel is used. Furthermore, we employ the multi-ROI support of the camera and stream up to four independent ROIs of typically 160 pixels × 160 pixels from the camera. The sample is illuminated to fill about half the pixel well depth of the camera. To support tracking rates of up to 3 kHz at the given magnification and achieve a contrast-rich diffraction pattern in the bead images (see below), we use the bright green emission lines of a fiber-coupled mercury arc lamp. The fiber exit is imaged onto the sample by two condenser lenses. Laser or superluminescent diode illumination provides also sufficient light but produces noticeable interference speckles. Therefore the non-coherent light source was used instead.
For image analysis we use a custom-written program that supports parallel calculations within the computer’s central processing unit (CPU) and the GPU (Fig. 1). The lateral bead positions (x,y) are determined in the CPU by correlating linear bead intensity profiles with their mirror profiles as described13,20. Bead images of a single frame are then copied into the GPU where the calculation of the radial intensity distribution with respect to the bead center is carried out (being the most processing time consuming step). Images are subdivided into smaller portions to use the high multi-threading capability of the GPU. Subsequently, radial intensity profiles are transferred to the CPU to obtain the axial bead position (z). This determination uses the diffraction rings of the bead image in overfocus (Fig.1). The acquired radial profile is compared in an automated fashion to a pre-recorded profile calibration table13,23. This table is obtained from imaging the same particle at increasing overfocus values with a step size of typically 25 nm. The three different parts of the tracking routine, i.e. image streaming together with lateral position determination, radial intensity calculation and axial position detection, are carried out in parallel. Thus, when the x,y-positions of beads from frame i are being calculated in the CPU, the GPU is calculating at the same moment the radial intensity profiles for frame i-1, while additional CPU threads are obtaining the z-positions for frame i-2.
Though the camera has a built-in dynamic fixed pattern noise (FPN) correction, we used a non-linear custom-developed FPN correction executed in the GPU. This software-encoded correction further reduces the FPN and avoids artifacts introduced by the dynamic nature of the built-in correction (see Supplementary Fig. 1). For each pixel the response-intensity curve is determined and approximated by a three-parameter function that is then used to remove the FPN. This corrects also for the non-linear pixel response at saturating light levels and inhomogeneous illumination, e.g. caused by dirt particles on optical elements along the beam path. Obtained bead positions were stored in memory together with the positions of the magnet and the nanopositioning stage. Bead tracking at kHz rates was thus only limited by the available computer memory and could be carried out continuously for more than 1h (107 frames at 2.5 kHz).
For multi-bead tracking a lower magnification with a conversion factor of 141 nm/pixel was used providing a field of view of 180×144 μm2. The camera was operated in full frame mode at up to 500 Hz. Due to the six times lower frame rate and the smaller magnification, a standard 625 nm LED provided optimal conditions for sample illumination. LED illumination was preferred here due to the limited life time of the mercury bulb. Streamed images were directly transferred to the GPU, where all the image processing steps described above were executed. Positions were determined from ROIs of 72 pixels ×72 pixels that comprised the particular bead. Obtained x,y,z positions were transferred every 100 frames to the computer memory.
Tracking the 3D position of fixed particles
We first tested the performance of our high-resolution mode by simultaneously tracking the positions of two 3 μm polystyrene beads that were tightly attached to the bottom of our fluidic cell at 2500 Hz. When plotting the displacement of the first bead with respect to the second bead (difference coordinate), the measured displacement oscillates around a rather stable mean value with root-mean-square (RMS) values of 1.3 Å and 1.8 Å for the lateral and the axial positions, respectively (Fig. 2a). When smoothing the position trajectories with a sliding average of 10 or 100 ms the noise is significantly reduced and RMS values down to 0.1 Å are obtained. This suggests that the noise of the bead position determination is largely uncorrelated between successive frames as would be expected for shot noise or white noise in general.
Figure 2. 3D tracking of fixed particles.
(a) Relative displacement of a 3 μm polystyrene bead bound firmly to the cover glass bottom of the fluidic cell with respect to a second firmly attached reference particle. Shown are time trajectories of the lateral (x,y) and the vertical (z) positions, power spectral densities (PSD) and Allan deviations. Position data was taken at 2500 Hz (light colors) and smoothed to 100 and 10 Hz (intermediate and dark colors, respectively). (b) Displacement of a single bead as function of time from the data set shown in a. Plots and coloring is as in a.
To further get insight into the tracking limits we calculated the power spectral density (PSD) as well as the Allan deviation of the determined trajectories. The PSDs are constant for all coordinates from about 10 Hz, indicating white noise and demonstrating that the positions are uncorrelated for time scales <100 ms. The x and y positions exhibit an increasing PSD for frequencies <10 Hz due to drift, while the axial position seems to be stable even at low frequencies. This behaviour is also seen in the Allan deviations that is a measure for the position error when smoothing the particle trajectory over a given time scale24. For small times τ the Allan deviation decreases with τ(−1/2) confirming uncorrelated noise. For the lateral direction a minimum noise (Allan deviation) of 0.1-0.2 Å is achieved between 100 ms and few seconds. For larger time scales drift compromises the tracking precision moderately, as can be also seen in the position trajectories. For the axial position the Allan deviation reaches values significantly below 0.1 Å for τ>100 ms. These two results demonstrate that we can determine relative position changes of fixed beads with a precision of 1 Å at kHz rates down to 0.1 Å at 10 Hz rates.
When plotting the differential position, the second bead serves as a reference that corrects for the drift as well as other noise sources that couple into the microscope setup. The absolute position of a single particle (Fig. 2b) shows consequently increased drift (most prominently along z, see also increasing Allan deviation for times >1s) as well as an increased RMS amplitude (along x,y). The latter arises mostly from discrete peaks in the PSDs (Fig.2b) that are absent for the differential positions. Similar peak patterns are also observed in the PSDs calculated from the x,y,z positions of the nanopositioning stage (Supplementary Fig. 2). This indicates that the increased RMS is due to mechanical vibrations that most likely couple in from the laboratory floor or due to sound waves equally affecting both beads. Nonetheless, despite drift and external vibrations, Allan deviations below 1 Å are reached on a time scale of 0.1 to 1 s for the positions of a single bead (Fig. 2b).
Resolving 3Å movements of fixed particles
As pointed out above, the Allan deviation characterizes the position error when smoothing the particle trajectory over a given time scale. It is however not equal to the minimum resolvable size of a sudden steps in the trajectory. Position accuracy (i.e. the position error) and resolvable step size are often not stringently distinguished in literature. Typically only steps amounting to few multiples of the position error at a given time scale can be clearly distinguished25. To test whether our setup is able to resolve base-pair sized steps, we moved our fluidic cell at fixed time intervals and alternating directions by 3 Å along a given stage direction, while tracking the position of a single bead at 2.5 kHz.
We could resolve 3 Å steps of the bead position along all three directions, with a clear correlation between bead and stage position (Fig. 3). For the lateral directions steps introduced at 1 s intervals could be detected. For the axial direction steps introduced at 1 s and even 100 ms intervals were discernible, where the higher temporal resolution is due to lower mechanical vibrations of the stage along z.
Figure 3. Detecting 3Ǻ steps of fixed particles.
(a) Resolving 0.3 nm steps in lateral direction of a firmly attached 3 μm polystyrene bead. Steps are induced every 1 s by moving the fluidic cell in which the particle is attached with a piezoelectric stage (see sketch). Both, the tracked bead position as well as the simultaneously recorded stage signal are shown over time. (b) Resolving 0.3 nm steps in axial direction that were induced every 1 s or every 100 ms. All data in the figure was recorded at 2500 Hz. For the 1 s steps it was smoothed to 100 Hz and 10 Hz (shown as light and dark colors), for the 100 ms steps to 500 Hz (light green) and 100 Hz (dark green).
Resolving movements of DNA tethered particles
We next investigated the performance of our particle tracking in a realistic magnetic tweezers configuration. Single 1.9 kbp DNA molecules were attached on one end to the bottom of the fluidic cell and on the other end to a 1 μm magnetic bead. Using a pair of magnets, the DNA was kept stretched under a constant force of 12 pN. The positions of the magnetic bead and of a 3 μm polystyrene bead serving as a reference were tracked simultaneously at 2.8 kHz in high-resolution mode. When plotting the position of the magnetic bead with respect to the reference bead the RMS amplitude is significantly increased in all directions due to the thermal fluctuations of the DNA tethered bead (Fig. 4a). The PSDs in the lateral directions exhibit characteristic Lorentzian shapes, since the pendulum motion of the bead is highly over damped. The restoring force in the pendulum configuration is proportional to the magnetic force. It can be experimentally determined from fitting the characteristic shape of the PSD or alternatively the Allan deviation26. Along the axial direction the entropic and the elastic rigidity of DNA determines the extent of the fluctuations14, which are at the applied force considerably smaller than in lateral direction (see trajectories and PSD levels in Fig. 4a). The Allan deviation reaches a minimum of ~1 Ǻ between 0.1 and 1 s, suggesting that (sub)-nanometer-sized DNA length changes are detectable. Indeed, when moving the fluidic cell in axial direction in alternating 1 nm steps at 1 s intervals the position changes can be clearly resolved in the magnetic bead position (Fig. 4b). When measuring the DNA length the noticeable drift of the magnetic bead position is corrected by the fixed reference particle that exhibits a similar drift. Even 5 Ǻ steps introduced at 1 s intervals are discernible in the magnetic bead position, although less pronounced than for the larger steps (Fig. 4b).
Figure 4. Length measurement of a DNA molecule under constant tension.
(a) Positions of a 1 μm magnetic bead tethered to a 1.9 kbp DNA molecule under an applied force of 12 pN. Shown are time trajectories of the relative displacements of the bead to an immobilized 3 μm reference bead and the corresponding PSDs and Allan deviations. Position data was taken at 2800 Hz and smoothed to 10 and 1 Hz (light and dark colors, respectively). (b) Resolving 1 nm and 0.5 nm steps of a DNA tethered magnetic bead (as in a) along the vertical direction. Steps in alternating direction were induced about once per second. Positions of the DNA tethered as well as of a fixed reference particle (see sketch) are shown as indicated in the plots. Position data was taken at 2800 Hz and smoothed to 100 and 10 Hz (shown in light and dark green, respectively).
When looking at the DNA length trajectory and its Allan deviation (differential position of magnetic bead in axial direction in Fig. 4a) it becomes apparent that for longer time scales the measurement accuracy is not limited by the Brownian motion of the particle but rather by a low frequency drift component. This component prevents the resolution of sudden steps better than 5 Ǻ. We can rule out that the drift arises from thermal drift of the objective focus with respect to the beads, since it is not reduced when keeping the reference bead at a fixed absolute position through a feedback. We further tested whether the low frequency drift occurs due to the usage of differently sized beads. The determined position may depend on the actual position in a slightly non-linear manner being more pronounced for the smaller magnetic beads. However, when tracking the position of a firmly attached 1 μm magnetic bead versus a firmly attached 3 μm polystyrene reference bead, no relative drift component was apparent (see Supplementary Fig. 3a). The RMS amplitude of the raw position signal was two-to threefold larger compared to the difference coordinate of two 3 μm beads. Nonetheless, Allan deviations that were significantly lower than 1 Ǻ were still obtained for all coordinates. In addition, 0.3 nm step-wise movements of the fluidic cell in both lateral and vertical direction could be clearly resolved in the magnetic bead position (see Supplementary Fig. 3b,c). This demonstrates that smaller, 1 μm-sized beads support high-resolution tracking with bp resolution. We therefore attribute the observed low frequency drift for DNA tethered beads to instabilities of the magnetic bead orientation 27, i.e. a nanoscale drift in bead alignment with the magnetic field.
Highly parallel particle tracking at 3 Å resolution
We next tested the parallel position tracking of 26 fixed polystyrene beads (3 μm diameter) in multi-bead mode at a rate of 420 Hz, at which simple LED illumination is sufficient (see above). Steps of 3 Ǻ introduced at 1 s intervals can be resolved in lateral and axial direction for all beads (see trajectories in Figs. 5a,c for three of the beads). The high resolution even in multi-bead mode is supported by the Allan deviations of the differential positions with respect to a reference bead (Figs. 5b,d). The Allan deviations for different beads are all very similar reaching values significantly below 1 Ǻ from ~0.1 s onwards.
Figure 5. Parallel tracking of multiple beads with sub-nanometer resolution.
The 3D positions of 26 firmly attached 3 μm polystyrene beads were tracked simultaneously at 420 Hz. (a) Example time traces of three of the 26 beads in which the piezoelectric stage was moved every 1 s by 0.3 nm in alternating direction along the x-axis (see sketch). Shown position data was smoothed to 105 Hz and 10 Hz (shown as light and dark red). (b) Allan deviations of the relative positions of all 26 beads against a reference bead in lateral direction. (c) Example time traces of three of the 26 beads in which the piezoelectric stage was moved every 1 s by 0.3 nm in alternating direction along the z-axis (see sketch). Shown position data was smoothed to 105 Hz and 10 Hz (shown as light and dark green). (d) Allan deviations of the relative positions of all 26 beads against a reference bead in vertical direction.
Discussion
Here we introduce a real-time particle tracking scheme with which base-pair sized movements of particles can be resolved on a (sub-)second time scale. We thus obtain a similar sensitivity as high-resolution optical tweezers with laser-based detection11 despite a much simpler setup design. For laser based detection only one or two beads can be tracked at a time with high resolution. Here we exploit the potential of camera based tracking and demonstrate that we can resolve base-pair sized steps in a highly parallel fashion on tens of beads simultaneously at only little compromised tracking accuracy.
When tracking two particles in parallel at highest spatial resolution (per frame taken) we obtain rates of up to 3 kHz (corresponding to processing of 150 MB/s of image data). Thus, our tracking scheme can also be applied to resolve fast dynamics of biomolecular systems at millisecond time scales and sub-nm spatial resolution. Compared to rates in laser tracking of up to MHz, our camera-based tracking is still dynamically limited. The frame transfer from the camera to the computer would at least allow for ~4-fold faster image acquisition. However, currently the computational power of CPU and GPU as well as the availability of non-coherent light sources with sufficient brightness do not permit faster tracking at comparable accuracy. Nonetheless, in the range of milliseconds to seconds, which is most often the time scale of interest for biomolecular systems, similar or even better spatial accuracies as for laser tracking are achieved. Previous camera-based tracking approaches reached rates of >10 kHz for 2D real time tracking20 and 3D tracking with image postprocessing22. The larger rates were obtained at expense of lower magnifications and thus much lower numbers of pixels per bead image. Taking more pixels per image of the same physical size provides a higher tracking accuracy per frame (compare Allan deviations at lowest times in Figs. 2 and 5)18. Additionally, it greatly reduces position bias due to pixilation effects28 (the dependence of the obtained bead position on the actual bead position with respect to the pixel lattice) and thus also drift. As a result the Allan deviations obtained here are at comparable time scales significantly lower than in previous reports.
The GPU-supported high-resolution real-time particle tracking presented here was applied within a regular magnetic tweezers scheme for which three dimensional position information is mandatory. It is based on previously established tracking methodology and can therefore be easily adapted for existing instruments. Accomplishing real-time tracking at kHz rates allows to cope with the massive image data being produced. This conveniently supports continuous long-term measurements with high spatio-temporal resolution but also in situ manipulation of objects, as typically carried out in tweezers measurements. Previous high-resolution magnetic tweezers applied image postprocessing, which limited the continuous acquisition to ~10 seconds22.
Beyond achieving base-pair accuracy for camera-based magnetic and optical tweezers systems, our particle tracking scheme will also provide a considerable improvement for particle tracking applications that need to handle large image sets. This includes highly parallelized experiments in multiplexed holographic optical tweezers19, multiplexed magnetic tweezers with up to 103 simultaneous measurements17, multiplexed particle experiments in liquid flow29 or fast real-time particle velocimetry30. Currently, the particle positions in these application are typically obtained not in real-time but rather from stored image data only after each measurement. Our real-time particle tracking scheme will not only allow for experiments with extended duration and thus better statistics but by using larger camera chips even more particles per experiment can be followed with higher accuracy. Given that we can analyze 26 particles at 420 Hz, it will be equally possible to follow about 200 particles at 60 Hz. Thus our approach will will greatly simplify highly parallel measurements of enzymatic activity16,29 and facilitate the detection of rare events. Also for single-molecule DNA sequencing applications relying on mechanical force detection31 our high-throughput real-time tracking promises significant improvements over current state-of-the-art technology. Furthermore, the outsourcing of the image processing to the GPU is ideally suited for experiments where camera-based real-time particle tracking is combined with simultaneously operating detection channels that require additional computational resources, such as in single-molecule torque measurements32,33 or in setups that combine tweezers experiments with single-molecule fluorescence methods34-36.
When detecting length changes on single DNA molecules, the presented magnetic tweezers data does not yet reach single-base pair resolution but rather 5-10 Ǻ. As explained above, we believe that this limitation stems from imperfections of the magnetic particles. With improved magnetic particles that possess a more stable anisotropy axis the mentioned problems may be overcome. Therefore, with the high tracking accuracy presented here and due to the stable and simple setup design, routine magnetic tweezers measurements on DNA with single base pair resolution should be achievable.
Methods
Particle tracking setup
The particle tracking setup consisted of a home-built inverted microscope body equipped with either a 100× (Olympus, N.A. 1.25) or a 40× (Zeiss, N.A. 1.3) oil immersion objective for high or multi-bead tracking modes, respectively. The bead sample is mounted onto a piezo-actuated nanopositioning stage (P-517.3CD, PI). The sample was illuminated using either a fiber-coupled mercury arc lamp (LSB610, LOT-Oriel) equipped with a 550/100 nm band pass filter (AHF Analysentechnik) or an LED emitting around 625 nm (CR5111AWY, Roithner Lasertechnik). Both light sources were combined using a 605 nm dichroic mirror (AHF Analysentechnik). Bead images were projected through a 400 mm tube lens onto a high-speed CMOS camera (Mikrotron EoSens CL MC1362). Two permanent NeFeB magnets (W-05-N50-G, Supermagnete) mounted onto a motorized stage above the sample were used to generate the magnetic field gradient for the magnetic tweezers experiments. A data acquisition card (USB-6281M, National Instruments) was used to record the signals from the nanopositioning stage in a synchronized manner. A trigger pulse from the camera at the beginning of a frame acquisition was used to generate a pulse train of 10 rectangular pulses during the frame acquisition time. The sub-pulses triggered then the acquisition of the stage positions. The 10 readouts were averaged to obtain a mean stage position per frame with reduced read noise. Data (images, stage positions) was streamed to a computer (Dell precision T7500 work station containing two 6 core CPUs) equipped with an image acquisition card (NI PCIe 1429, National Instruments) and a fast GPU (GeForce GTX 480, Nvidia). Setup control as well as data acquisition and processing were carried out by a custom-developed software (Labview 2010 64-bit version, National Instruments). GPU programming was done in CUDA C and compiled as a DLL for embedding into Labview. An implementation of our software supporting offline-tracking can be downloaded from the author’s webpage.
Tracking experiments
Fluidic cells were built from two cover slides and a parafilm spacer that formed the final chamber. The bottom cover slip was spin-coated on the inside with polystyrene prior to cell assembly. The cell was mounted on the setup using a custom-designed plate on the nanopositioning stage. 3 μm carboxylated polystyrene beads (Invitrogen) in 1M NaCl were added and incubated for at least 1h to ensure adherence to the polystyrene film. Subsequently, phosphate buffered saline (PBS) was added for the measurements with fixed beads. Magnetic tweezers experiments with DNA tethered beads were carried out14 using a 1.9 kbp DNA molecule carrying at either end a 600 bp DNA fragment with multiple digoxigenin or biotin modifications as previously described37. In brief, after adhering the fixed beads, the fluidic cell was incubated with 50 μg/ml anti-digoxigenin in PBS for 1h. Afterwards it was incubated for 1h with 10 mg/ml BSA to prevent non-specific binding to the bottom of the cell. The DNA construct was bound to 1 μm magnetic beads in PBS and added to the fluidic cell. After 5 min non-tethered beads were removed by approaching the magnets and subsequent buffer flushing. Subsequently sets of calibration profiles were recorded for appropriate beads and tracking experiments were started. For the experiments with fixed 1 μm magnetic beads (Supplementary Fig. 3), both magnetic and reference beads were adhered to bare (uncoated) cover slides. After sample drying the slide was placed for 3 min on a hot plate at 150°C to allow bead fixation as described22. Afterwards the fluidic cell was assembled and PBS was added in order to carry out the tracking measurements.
Data analysis
Smoothing of shown trajectories was carried out using a sliding average with the indicated window size. PSDs were calculated from long trajectories that were split into 40 equally long parts. PSDs of these sub-trajectories were average to provide the PSDs shown. Allan deviations were calculated from overlapping time intervals using a computationally efficient form26,38.
Supplementary Material
Acknowledgements
We greatly acknowledge stimulating discussions with Friedrich Schwarz and experimental support by Felix Kemmerich. This work was supported by the Deutsche Forschungsgemeinschaft (DFG, SE 1646/1-1), a NanoSci-E+ collaborative proposal (SE 1646/5-1) and a starting grant of the European Research Council (261224) to R.S.
Footnotes
Conflict of interest
The authors declare that they have no conflicts of interest.
References
- 1.Klaue D, et al. Fork sensing and strand switching control antagonistic activities of RecQ helicases. Nat. Commun. 2013;4:2024. doi: 10.1038/ncomms3024. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Manosas M, Perumal SK, Croquette V, Benkovic SJ. Direct observation of stalled fork restart via fork regression in the T4 replication system. Science. 2012;338:1217–1220. doi: 10.1126/science.1225437. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Dulin D, Lipfert J, Moolman MC, Dekker NH. Studying genomic processes at the single-molecule level: introducing the tools and applications. Nat. Rev. Genet. 2013;14:9–22. doi: 10.1038/nrg3316. [DOI] [PubMed] [Google Scholar]
- 4.Seidel R, Dekker C. Single-molecule studies of nucleic acid motors. Curr. Opin. Struct. Biol. 2007;17:80–86. doi: 10.1016/j.sbi.2006.12.003. [DOI] [PubMed] [Google Scholar]
- 5.Keyser UF, et al. Direct force measurements on DNA in a solid-state nanopore. Nat. Phys. 2006;2:473–477. [Google Scholar]
- 6.Franosch T, et al. Resonances arising from hydrodynamic memory in Brownian motion. Nature. 2011;478:85–88. doi: 10.1038/nature10498. [DOI] [PubMed] [Google Scholar]
- 7.Asbury CL, Fehr AN, Block SM. Kinesin moves by an asymmetric hand-over-hand mechanism. Science. 2003:2130–2134. doi: 10.1126/science.1092985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Abbondanzieri EA, Greenleaf WJ, Shaevitz JW, Landick R, Block SM. Direct observation of base-pair stepping by RNA polymerase. Nature. 2005;438:460–465. doi: 10.1038/nature04268. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Qi Z, Pugh RA, Spies M, Chemla YR. Sequence-dependent base pair stepping dynamics in XPD helicase unwinding. Elife. 2013;2:e00334. doi: 10.7554/eLife.00334. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Comstock MJ, Ha T, Chemla YR. Ultrahigh-resolution optical trap with single-fluorophore sensitivity. Nat. Methods. 2011;8:335–340. doi: 10.1038/nmeth.1574. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Mahamdeh M, Schäffer E. Optical tweezers with millikelvin precision of temperature-controlled objectives and base-pair resolution. Opt. Express. 2009;17:17190–17199. doi: 10.1364/OE.17.017190. [DOI] [PubMed] [Google Scholar]
- 12.Crocker JC, Grier DG. Methods of digital video microscopy for colloidal studies. J. Colloid Interface Sci. 1996;179:298–310. [Google Scholar]
- 13.Gosse C, Croquette V. Magnetic tweezers: micromanipulation and force measurement at the molecular level. Biophys. J. 2002;82:3314–3329. doi: 10.1016/S0006-3495(02)75672-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Klaue D, Seidel R. Torsional stiffness of single superparamagnetic microspheres in an external magnetic field. Phys. Rev. Lett. 2009;102:028302. doi: 10.1103/PhysRevLett.102.028302. [DOI] [PubMed] [Google Scholar]
- 15.De Vlaminck I, Dekker C. Recent advances in magnetic tweezers. Annu. Rev. Biophys. 2012;41:453–472. doi: 10.1146/annurev-biophys-122311-100544. [DOI] [PubMed] [Google Scholar]
- 16.Ramanathan SP, et al. Type III restriction enzymes communicate in 1D without looping between their target sites. Proc. Natl. Acad. Sci. U.S.A. 2009;106:1748–1753. doi: 10.1073/pnas.0807193106. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.De Vlaminck I, et al. Highly parallel magnetic tweezers by targeted DNA tethering. Nano Lett. 2011;11:5489–5493. doi: 10.1021/nl203299e. [DOI] [PubMed] [Google Scholar]
- 18.Ribeck N, Saleh OA. Multiplexed single-molecule measurements with magnetic tweezers. Rev. Sci. Instrum. 2008;79:094301. doi: 10.1063/1.2981687. [DOI] [PubMed] [Google Scholar]
- 19.Gibson GM, et al. A compact holographic optical tweezers instrument. Rev. Sci. Instrum. 2012;83:113107. doi: 10.1063/1.4768303. [DOI] [PubMed] [Google Scholar]
- 20.Otto O, et al. Real-time particle tracking at 10,000 fps using optical fiber illumination. Opt. Express. 2010;18:22722–22733. doi: 10.1364/OE.18.022722. [DOI] [PubMed] [Google Scholar]
- 21.Otto O, et al. High-speed video-based tracking of optically trapped colloids. J. Opt. 2011;13:4. [Google Scholar]
- 22.Lansdorp BM, Tabrizi SJ, Dittmore A, Saleh OA. A high-speed magnetic tweezer beyond 10,000 frames per second. Rev. Sci. Instrum. 2013;84:044301. doi: 10.1063/1.4802678. [DOI] [PubMed] [Google Scholar]
- 23.Speidel M, Jonáš A, Florin EL. Three-dimensional tracking of fluorescent nanoparticles with subnanometer precision by use of off-focus imaging. Opt. Lett. 2003;28:69–71. doi: 10.1364/ol.28.000069. [DOI] [PubMed] [Google Scholar]
- 24.Czerwinski F, Richardson AC, Oddershede LB. Quantifying noise in optical tweezers by allan variance. Opt. Express. 2009;17:13255–13269. doi: 10.1364/oe.17.013255. [DOI] [PubMed] [Google Scholar]
- 25.Wallin AE, Salmi A, Tuma R. Step length measurement–theory and simulation for tethered bead constant-force single molecule assay. Biophys. J. 2007;93:795–805. doi: 10.1529/biophysj.106.097915. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Lansdorp BM, Saleh OA. Power spectrum and Allan variance methods for calibrating single-molecule video-tracking instruments. Rev. Sci. Instrum. 2012;83:025115. doi: 10.1063/1.3687431. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.van Reenen A, Gutiérrez-Mejía F, van Ijzendoorn LJ, Prins MWJ. Torsion profiling of proteins using magnetic particles. Biophys. J. 2013;104:1073–1080. doi: 10.1016/j.bpj.2013.01.027. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.van Loenhout MTJ, Kerssemakers JWJ, De Vlaminck I, Dekker C. Non-bias-limited tracking of spherical particles, enabling nanometer resolution at low magnification. Biophys. J. 2012;102:2362–2371. doi: 10.1016/j.bpj.2012.03.073. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Hamdan SM, Loparo JJ, Takahashi M, Richardson CC, van Oijen AM. Dynamics of DNA replication loops reveal temporal control of lagging-strand synthesis. Nature. 2009;457:336–339. doi: 10.1038/nature07512. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Jainski C, Lu L, Dreizler A, Sick V. High-speed micro particle image velocimetry studies of boundary-layer flows in a direct-injection engine. Int. J. Engine Res. 2013;14:247–259. [Google Scholar]
- 31.Ding F, et al. Single-molecule mechanical identification and sequencing. Nat. Methods. 2012;9:367–372. doi: 10.1038/nmeth.1925. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Kauert DJ, Kurth T, Liedl T, Seidel R. Direct mechanical measurements reveal the material properties of three-dimensional DNA origami. Nano Lett. 2011;11:5558–5563. doi: 10.1021/nl203503s. [DOI] [PubMed] [Google Scholar]
- 33.Janssen XJA, et al. Electromagnetic torque tweezers: a versatile approach for measurement of single-molecule twist and torque. Nano Lett. 2012;12:3634–3639. doi: 10.1021/nl301330h. [DOI] [PubMed] [Google Scholar]
- 34.Brutzer H, Schwarz FW, Seidel R. Scanning evanescent fields using a pointlike light source and a nanomechanical DNA gear. Nano Lett. 2012;12:473–478. doi: 10.1021/nl203876w. [DOI] [PubMed] [Google Scholar]
- 35.Oberstrass FC, Fernandes LE, Bryant Z. Torque measurements reveal sequence-specific cooperative transitions in supercoiled DNA. Proc. Natl. Acad. Sci. U.S.A. 2012;109:6106–6111. doi: 10.1073/pnas.1113532109. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Schwarz FW, et al. The helicase-like domains of type III restriction enzymes trigger long-range diffusion along DNA. Science. 2013;340:353–356. doi: 10.1126/science.1231122. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Brutzer H, Luzzietti N, Klaue D, Seidel R. Energetics at the DNA supercoiling transition. Biophys. J. 2010;98:1267–1276. doi: 10.1016/j.bpj.2009.12.4292. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Walter T. Characterizing frequency stability: a continuous power-law model with discrete sampling. IEEE Trans. Instrum. Meas. 1994;43:69–79. [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.