Abstract
An ideal substance to provide convenient and accurate targeting for sentinel lymph node (SLN) mapping during robotic-assisted surgery has yet to be found. We used an animal model to determine the ability of the FireFly camera system to detect fluorescent SLNs after administration of a dual-labeled molecular imaging agent.
Methods
We injected the footpads of New Zealand White rabbits with 1.7 or 8.4 nmol of tilmanocept labeled with 99mTc and a near-infrared fluorophore, IRDye800CW. One and 36 h after injection, popliteal lymph nodes, representing the SLNs, were dissected with the assistance of the FireFly camera system, a fluorescence-capable endoscopic imaging system. After excision of the paraaortic lymph nodes, which represented non-SLNs, we assayed all lymph nodes for radioactivity and fluorescence intensity.
Results
Fluorescence within all popliteal lymph nodes was easily detected by the FireFly camera system. Fluorescence within the lymph channel could be imaged during the 1-h studies. When compared with the paraaortic lymph nodes, the popliteal lymph nodes retain greater than 95% of the radioactivity at both 1 and 36 h after injection. At both doses (1.7 and 8.4 nmol), the popliteal nodes had higher (P < 0.050) optical fluorescence intensity than the paraaortic nodes at the 1- and 36-h time points.
Conclusion
The FireFly camera system can easily detect tilmanocept labeled with a near-infrared fluorophore at least 36 h after administration. This ability will permit image acquisition and subsequent verification of fluorescence-labeled SLNs during robotic-assisted surgery.
Keywords: fluorescent tilmanocept, sentinel lymph node mapping, robotic-assisted surgery
Sentinel lymph node (SLN) detection and excision is becoming incorporated in breast cancer and melanoma surgery (1,2). However, there has been less progress with genitourinary cancers largely because of the limitations in available agents with favorable timing parameters from injection to imaging and surgery. For example, prostate cancer has considerable variation regarding the decision to perform, or the extent of, pelvic lymph node dissection based on preoperative risk factors (3–5). The previously limited pelvic lymph node dissection usually does not include high-risk nodes, causing the current risk of positive lymph nodes to be lower than predicted (5). SLN biopsy in prostate cancer has been shown to accurately predict positive lymph nodes and, pending further research, may parallel the excellent results of SLN biopsy in breast cancer and melanoma (6,7).
Limitations in previous studies include logistics and cumbersome intraoperative γ detectors. However, the endoscope used in minimally invasive surgery has provided a platform for fluorescence-guided surgery. The United States Food and Drug Administration approved 99mTc-labeled tilmanocept (8), which is the first receptor-targeted radiopharmaceutical approved for lymphatic mapping (9–12). The benefits of receptor targeting allow the agent to bind and remain within SLN, providing logistic flexibility. Radiolabeled tilmanocept can be used to provide a preoperative roadmap using imaging with SPECT/CT (11) or PET/CT (13); however, a laparoscopic γ detector would still be necessary (14). The ideal agent for robotic surgery would be the use of tilmanocept also labeled with a fluorophore for intraoperative visualization by the currently used FireFly endoscope (Da Vinci Si surgical robot; Intuitive Surgical) and the option of preoperative imaging.
In preparation for a phase 1 clinical trial, we investigated the use of fluorescence-labeled tilmanocept for SLN imaging using the FireFly endoscope. Our primary goal was to confirm the ability of the robotic camera to visualize the fluorescence accumulated within the SLN. We tested this ability at different molar doses of fluorescent tilmanocept and at different times after administration. Confirmation of SLN fluorescence imaging by the FireFly camera will provide us with the approximate molar dose and timing parameters with which to perform robotic-assisted fluorescence-based mapping of pelvic SLNs many hours after an ultrasound-guided transrectal injection of fluorescence-labeled tilmanocept into the canine prostate gland.
MATERIALS AND METHODS
Experimental Design
These experiments were designed to test the ability of the Da Vinci Si FireFly camera system to detect fluorescent SLNs resulting from the accumulation of 800CW-tilmanocept. Our goal was to determine the amount of fluorescence-labeled tilmanocept that could be detected by the FireFly system but would not saturate the SLN and carry fluorescence to downstream lymph nodes, which would be falsely identified as SLNs. We elected to use a rabbit model that was used during the development of 99mTc-tilmanocept (15–17). In this model, a hind-limb administration of the fluorescence-labeled radiotracer would define the popliteal lymph node as the sentinel node and the paraaortic lymph nodes as the downstream lymph nodes. At a predetermined time point, the rabbits were euthanized before fluorescence-guided dissection using the FireFly endoscope attached to the Da Vinci Si robotic surgical system. Images were acquired with the standard clinical software and a modification that permitted the visualization of only the green fluorescence image in the operator console of the surgical robot. This modification, which will be incorporated into future versions of the da Vinci software, essentially turned off the white light of the camera system. After euthanasia, images were acquired over the popliteal fossa before surgical incision and after surgical exposure, when the SLN can be viewed without attenuation by overlying tissue. Four rabbits were used for each of 2 dose levels (1.7 and 8.4 nmol) and each of 2 imaging time points (1 and 36 h), for a total of 16 rabbits. After euthanasia, the popliteal and paraaortic lymph nodes were excised via open dissection.
Imaging Agent Preparation and Administration
The preparation and quality control of 99mTc-labeled 800CW-tilmanocept was performed using a previously described method (18). The 800CW-tilmanocept used in this study consisted of an average of 1.5 IRDye800CW molecules covalently attached to each tilmanocept molecule. The resulting molecular weight was approximately 18,000 g/mol. Quality control before each animal study was performed using high-performance liquid chromatography and instant thin-layer chromatography; both methods used fluorescence and radioactivity detection. Acceptance criteria required that both the radiochemical purity and the fluorescence purity be greater than 97%.
Our animal protocol was approved by the University of California, San Diego, Institutional Animal Care and Use Committee, and the research staff was appropriately trained. We anesthetized New Zealand White rabbits with ketamine (Fort Dodge Animal Health) and xylazine (Vedco Inc.). The 0.10-mL injections each contained 3.7–7.4 MBq (0.10–0.20 mC) of 99mTc and 1 of 2 quantities of fluorescence-labeled tilmanocept (1.7 or 8.4 nmol). Each volume was administered to both hind footpads of each rabbit with a 28-gauge needle. We monitored the rabbits after anesthesia visually and with an oximeter that measures heart rate and functional oxygen saturation.
FireFly Fluorescence Imaging Endoscope
The FireFly fluorescence imaging endoscope is an optional component of the DaVinci Si robotic-assisted surgical system. The endoscope uses near-infrared light with an 805-nm-wavelength excitation laser source. We investigated the ideal visualization characteristics of 800CW-tilmanocept by turning off the background white light of the FireFly system. We also tested the detection ability of the camera system using the standard clinical firmware and hardware.
Nuclear Counting
Each node was placed in a plastic scintillation vial and assayed for radioactivity using a γ well counter (100- to 200-keV energy window, Gamma 9000; Beckman Instruments). The nodes were compared with a counting standard that was prepared from a known dilution of the injected material. The accumulation of 99mTc-800CW-tilmanocept within each SLN was expressed as percentage injected dose, which was calculated by comparing the tissue counts with the counting standard. The amount of fluorescent dye, IRDye800CW, was calculated by multiplying the percentage injected dose times the number of dyes per tilmanocept times the amount of 800CW-tilmanocept administered to each hind paw times 0.01. The percentage extraction ESLN of popliteal lymph nodes for each animal was calculated by Equation 1, where the cpmLP, cpmRP, and cpmPA represent the counts per minute within the left popliteal, right popliteal, and paraaortic lymph nodes, respectively.
Eq. 1 |
Fluorescence Imaging
Ex vivo optical imaging was performed with a time-correlated single-photon fluorescence imaging system (Optix MX2; Advanced Research Technologies). Images were acquired for each excised lymph node using a scan resolution of 1 mm2 and a 758-nm pulsed laser diode with an 800-MHz frequency and a 0.3-s integration time. Emitted photons were collected through a pair of 780-nm long-pass filters and a 782-nm band-pass filter, both with a 20-nm bandwidth. For each node, the total fluorescence intensity (counts per minute) was determined by an operator-defined region of interest and reported in kilocounts per second per microwatt (kcts·s−1·μW−1).
Statistical Analysis
The Friedman test for nonparametric paired samples (right popliteal, left popliteal, and paraaortic lymph nodes) was used, with a P value of less than 0.05 needed for statistical significance. Data were analyzed using the SPSS statistical package (version 21; IBM) and reported as mean ± SD.
RESULTS
Visualization of Fluorescent SLNs
The FireFly endoscope attached to the Da Vinci Si robotic surgical system visualized all of the popliteal lymph nodes at 1 and 36 h after administration of 1.7 or 8.4 nmol of fluorescence-labeled tilmanocept. Fluorescence visualization of all lymph nodes was possible with the FireFly endoscope using both the factory settings and the modified software, which turned off the white-light image at the viewing consol. Visualization of afferent lymph channels was possible 1 h after injection. Surgical exposure was not required for visualization of the SLN fluorescence when the duration between imaging and injection was 36 h. Four lymph nodes of the 1-h studies were also visualized behind the muscle layer without the need for surgical exposure.
Figure 1 demonstrates the fluorescence detection of an SLN and its afferent lymph channels by the FireFly camera. This was accomplished at the lower of the 2 doses, 1.7 nmol of fluorescence-labeled tilmanocept, and without surgical exposure of the lymph node or the afferent lymph channels. Figure 1A is a bright-field image of a rabbit hind-limb acquired 1 h after a 1.7-nmol injection of 800CW-tilmanocept. After the switch to fluorescence mode (Fig. 1B), fluorescence could be visualized traveling up the lymphatic channel (arrow) to the SLN located in the popliteal fossa (arrow in Fig. 1C). Figure 1D is a fluorescence-mode image of the SLN (arrow), which accumulated 15 pmol of fluorescence-labeled tilmanocept to which 25 pmol of IRDye800CW was covalently attached. After excision, the SLN produced a fluorescence intensity of 8.6 kcts·s−1·μW−1. The paraaortic lymph nodes contained 0.14 pmol of 800CW-tilmanocept (0.20 pmol IRDye800CW), which produced a fluorescence intensity of 0.16 kcts·s−1·μW−1. The percentage extraction was 98.3%. The fluorescence images (Figs. 1B and 1D) use a modification of the console software that allows visualization of only the fluorescence image from the FireFly camera.
SLN Accumulation
Table 1 lists the means and relative SDs of the various measurements of SLN accumulation—percentage injected dose, amount of fluorescent dye, percentage extraction, and fluorescence intensity—for each of the experimental groups (1 h after a 1.7-nmol 800CW-tilmanocept injection, 36 h after a 1.7-mol injection, 1 h after an 8.4-nmol injection, and 36 h after an 8.4-nmol injection).
TABLE 1.
Number of SLNs | Location of SLNs | Time (h) | Tilmanocept injected (nmol) | Percentage injected dose* | IRDye800CW (nmol) | Extraction (%)* | Fluorescence intensity (kcts s−1 μWminus;1)† |
---|---|---|---|---|---|---|---|
8 | Popliteal | 1.0 | 1.7 | 0.95 ± 0.78 | 0.024 ± 0.020‡ | 99.4 ± 4.0 | 6.22 ± 2.45‡ |
8 | Popliteal | 36.0 | 1.7 | 0.56 ± 0.39‡ | 0.014 ± 0.010‡ | 98.5 ± 0.9 | 8.62 ± 3.72‡ |
8 | Popliteal | 1.0 | 8.4 | 1.64 ± 0.77 | 0.21 ± 0.10 | 95.1 ± 5.2 | 19.1 ± 9.23 |
8 | Popliteal | 36.0 | 8.4 | 1.21 ± 0.33 | 0.15 ± 0.04 | 94.2 ± 5.9 | 11.6 ± 4.24 |
Measured by γ well counter (100–200 keV).
Measured by Optix MX2.
P < 0.05 for comparison with data from same time but different amount of injected tilmanocept.
Data are mean ± SD.
SLN accumulation was higher at 1 h after injection than at the later time point. At 1 h, the mean and SD of the percentage injected dose from the 8 SLNs receiving the 1.7-nmol dose of 800CW-tilmanocept was 0.95% ± 0.78%; at 36 h the percentage injected dose was 0.56% ± 0.39%. The 8.4-nmol dose delivered 1.64% ± 0.77% at 1 h and 1.21% ± 0.33% at 36 h. 800CW-tilmanocept delivered more fluorescent dye using the higher dose (8.4 nmol) at 1 h from injection (0.21 ± 0.10 vs. 0.024 ± 0.020 pmol; P < 0.05) and at 36 h after injection (0.15 ± 0.04 vs. 0.014 ± 0.0.010 pmol; P < 0.05). The fluorescence intensity of all the paraaortic nodes was less than 10% of the popliteal lymph nodes. At both doses (1.7 and 8.4 nmol), the popliteal nodes had higher (P < 0.050) optical fluorescence intensity than the paraaortic nodes at the 1- and 36-h time points. The percentage SLN extraction for all the experimental groups was greater than 95%, indicating the lack of SLN saturation at both low and high doses (1.7 and 8.4 nmol) of 800CW-tilmanocept. The 8.4-nmol dose produced higher fluorescence intensity with the SLNs at both time points: 19.1 ± 9.23 kcts·s−1·μW−1 1 h after injection and 11.6 ± 4.24 kcts·s−1·μW−1 36 h after injection. The 1.7-nmol dose of 800CW-tilmanocept produced a fluorescence intensity of 6.22 ± 2.45 kcts·s−1·μW−1 at 1 h and 8.62 ± 3.72 kcts·s−1·μW−1 at 36 h. Increasing the amount of 800CW-tilmanocept injected produced a significantly higher (P < 0.05) fluorescence intensity at both time points.
DISCUSSION
This study demonstrated that the FireFly endoscopic camera system of the Da Vinci Si surgical system can image fluorescent SLNs resulting from an 8.4-nmol injection of 800CW-tilmanocept and that this can be accomplished without receptor saturation within the SLN. Moreover, when imaging is performed at the appropriate time, the FireFly camera can visualize fluorescence from afferent lymph channels.
Previous animal studies using the New Zealand White rabbit model have shown that without a molecular or physiologic mechanism to retain the imaging agent within the lymph node, nearly all 99mTc had passed through the SLNs by 6 h after injection (15–17). Using 99mTc-labeled 800CW-tilmanocept, we show that radioactivity levels can be detected in popliteal lymph nodes at 1 and 36 h after footpad injection in a rabbit model. The molecule is retained within the popliteal lymph node and does not significantly migrate to the next level of lymph nodes (paraaortic) or significantly dissipate over time. These results suggest that the receptor binds within 1 h and will stay localized up to 36 h, allowing for flexibility in image acquisition with nuclear medicine scanning before surgery. The use of imaging before surgery to identify SLNs has been shown to reduce operative time when compared with γ probe–guided lymph node dissections during radical prostatectomy (19,20).
Pelvic lymphadenectomy during radical prostatectomy provides staging information that may guide adjuvant therapy (21–25). The extent and definition of the pelvic lymph node dissection are controversial (5,26,27). Studies have shown that limited pelvic lymph node dissection resects only 35% of the primary landing zones of prostate-draining lymph nodes (28). Therefore, the SLN dissection has become an emerging concept during radical prostatectomy to tailor surgery and decrease the risk-to-benefit ratio of lymph node dissection by resecting only high-yield nodes (7,29,30). Moreover, this technique may reduce the complications of increasingly extensive lymph node dissections (i.e., lymphocele, lymphedema, deep venous thrombosis, and pulmonary embolism) (31). One of the initial studies of SLN dissection was performed by Wawroschek et al. by injecting 99mTc-labeled colloid into the prostate and performing dynamic lymphoscintigraphy followed by surgery with γ-probe guidance the next day (29). This concept was later confirmed in a study with over 1,000 prostatectomies. That study noted that only 1% of metastases were found in patients with negative SLNs; however, the study did not provide intraoperative visual confirmation with fluorescence (32).
Previous investigations have added indocyanine green (ICG) to fluorescently image lymph channels and SLNs. One study used 99mTc-labeled Nanocoll (GE Healthcare) to image before radical prostatectomy followed by a separate ICG injection at the time of surgery (33). A separate study used a mixture of ICG and 99mTc-labeled Nanocoll imaged by SPECT/CT 2 h after injection, followed by surgery within the hour (20). The use of an ICG-radiolabeled Nanocoll mixture assumes that the dye binds to Nanocoll with adequate affinity for valid SLN mapping. Both studies using ICG detection showed accurate results (34); however, the use of ICG in this manner requires multiple injections or an extra compounding step by a pharmacist. Moreover, Nanocoll is prepared from human blood and can have similar risks to transfusion. Lastly, Nanocoll is not available in the United States. Therefore, using a non–blood-based dual-labeled receptor-targeted molecule such as 800CW-tilmanocept may have better logistic properties with reduced risk. In addition to determining the benefit of the 36-h interval, we also established that the larger dose (8.4 nmol) provided improved fluorescence without saturation and migration to next-level lymph nodes.
CONCLUSION
99mTc-tilmanocept covalently tagged with IRDye800CW can provide fluorescence detection of SLNs by the FireFly endoscope used during robotic surgery. Detection can be achieved with and without background white light. The molecule remains in the SLN at the 2 tested doses for at least 36 h to allow image acquisition and subsequent surgical verification via fluorescence guidance. Further in vivo (35) and subsequent human studies are needed to provide more information on the feasibility and accuracy of this technology during robotic surgery.
Acknowledgments
This research was supported by the National Cancer Institute (P50 CA114745, P30 CA023100) and Intuitive Surgical. Intuitive provided software modifications to the Da Vinci Si robotic system and the FireFly endoscope adjustments. Otherwise they were not involved in the design, analysis, or writing of this article. Dr. Vera is the inventor of tilmanocept. Dr. Kane is a consultant or has received honoraria from Intuitive Surgical Inc.
We thank LiCOR Biosciences for supplying the IRDye 800CW NHS-ester dye and Dr. Jonathan Sorger of Intuitive Surgical for his assistance with software modifications of the Da Vinci Si robotic surgical system.
Footnotes
No other potential conflict of interest relevant to this article was reported.
References
- 1.Krag DN, Anderson SJ, Julian TB, et al. Sentinel-lymph-node resection compared with conventional axillary-lymph-node dissection in clinically node-negative patients with breast cancer: overall survival findings from the NSABP B-32 randomised phase 3 trial. Lancet Oncol. 2010;11:927–933. doi: 10.1016/S1470-2045(10)70207-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Valsecchi ME, Silbermins D, de Rosa N, Wong SL, Lyman GH. Lymphatic mapping and sentinel lymph node biopsy in patients with melanoma: a meta-analysis. J Clin Oncol. 2011;29:1479–1487. doi: 10.1200/JCO.2010.33.1884. [DOI] [PubMed] [Google Scholar]
- 3.Briganti A, Blute ML, Eastham JH, et al. Pelvic lymph node dissection in prostate cancer. Eur Urol. 2009;55:1251–1265. doi: 10.1016/j.eururo.2009.03.012. [DOI] [PubMed] [Google Scholar]
- 4.Touijer KA, Ahallal Y, Guillonneau BD. Indications for and anatomical extent of pelvic lymph node dissection for prostate cancer: practice patterns of uro-oncologists in North America. Urol Oncol. 2013;31:1517–1521. doi: 10.1016/j.urolonc.2012.04.021. [DOI] [PubMed] [Google Scholar]
- 5.Yuh BE, Ruel NH, Mejia R, Wilson CM, Wilson TG. Robotic extended pelvic lymphadenectomy for intermediate- and high-risk prostate cancer. Eur Urol. 2012;61:1004–1010. doi: 10.1016/j.eururo.2012.01.048. [DOI] [PubMed] [Google Scholar]
- 6.Winter A, Kneib T, Henke RP, Wawroschek F. Sentinel lymph node dissection in more than 1200 prostate cancer cases: rate and prediction of lymph node involvement depending on preoperative tumor characteristics. Int J Urol. 2014;21:58–63. doi: 10.1111/iju.12184. [DOI] [PubMed] [Google Scholar]
- 7.Holl G, Dorn R, Wengenmair H, Weckermann D, Sciuk J. Validation of sentinel lymph node dissection in prostate cancer: experience in more than 2,000 patients. Eur J Nucl Med Mol Imaging. 2009;36:1377–1382. doi: 10.1007/s00259-009-1157-2. [DOI] [PubMed] [Google Scholar]
- 8.FDA approves Lymphoseek to help locate lymph nodes in patients with certain cancers. J Nucl Med. 2013;54(5):20N. [Google Scholar]
- 9.Leong SP, Kim J, Ross M, et al. A phase 2 study of 99mTc-tilmanocept in the detection of sentinel lymph nodes in melanoma and breast cancer. Ann Surg Oncol. 2011;18:961–969. doi: 10.1245/s10434-010-1524-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Sondak VK, King DW, Zager JS, et al. Combined analysis of phase III trials evaluating [99mTc]tilmanocept and vital blue dye for identification of sentinel lymph nodes in clinically node-negative cutaneous melanoma. Ann Surg Oncol. 2013;20:680–688. doi: 10.1245/s10434-012-2612-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Wallace AM, Han LK, Povoski SP, et al. Comparative evaluation of [99mTc] tilmanocept for sentinel lymph node mapping in breast cancer patients: results of two phase 3 trials. Ann Surg Oncol. 2013;20:2590–2599. doi: 10.1245/s10434-013-2887-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Marcinow AM, Hall N, Byrum E, Teknos TN, Old MO, Agrawal A. Use of a novel receptor-targeted (CD206) radiotracer, 99mTc-tilmanocept, and SPECT/CT for sentinel lymph node detection in oral cavity squamous cell carcinoma: initial institutional report in an ongoing phase 3 study. JAMA Otolaryngol Head Neck Surg. 2013;139:895–902. doi: 10.1001/jamaoto.2013.4239. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Stroup SP, Kane CJ, Farchshchi-Heydari S, et al. Preoperative sentinel lymph node mapping of the prostate using PET/CT fusion imaging and Ga-68-labeled tilmanocept in a dog model. Clin Exp Metastasis. 2012;29:673–680. doi: 10.1007/s10585-012-9498-9. [DOI] [PubMed] [Google Scholar]
- 14.Wallace AM, Ellner SJ, Mendez J, et al. Minimally invasive sentinel lymph node mapping of the pig colon with Lymphoseek. Surgery. 2006;139:217–223. doi: 10.1016/j.surg.2005.06.038. [DOI] [PubMed] [Google Scholar]
- 15.Vera DR, Wisner ER, Stadalnik RC. Sentinel node imaging via a nonparticulate receptor-binding radiotracer. J Nucl Med. 1997;38:530–535. [PubMed] [Google Scholar]
- 16.Vera DR, Wallace AM, Hoh CK, Mattrey RF. A synthetic macromolecule for sentinel node detection: [99mTc]DTPA-mannosyl-dextran. J Nucl Med. 2001;42:951–959. [PubMed] [Google Scholar]
- 17.Hoh CK, Wallace AM, Vera DR. Preclinical studies of [99mTc]DPTA-mannosyl-dextran. Nucl Med Biol. 2003;30:457–464. doi: 10.1016/s0969-8051(03)00028-3. [DOI] [PubMed] [Google Scholar]
- 18.Qin Z, Hall DJ, Liss MA, et al. Optimization via specific fluorescence brightness of a receptor-targeted probe for optical imaging and positron emission tomography of sentinel lymph nodes. J Biomed Opt. 2013;18:101315. doi: 10.1117/1.JBO.18.10.101315. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Warncke SH, Mattei A, Fuechsel FG, Z’Brun S, Krause T, Studer UE. Detection rate and operating time required for gamma probe-guided sentinel lymph node resection after injection of technetium-99m nanocolloid into the prostate with and without preoperative imaging. Eur Urol. 2007;52:126–132. doi: 10.1016/j.eururo.2007.01.050. [DOI] [PubMed] [Google Scholar]
- 20.van der Poel HG, Buckle T, Brouwer OR, Valdes Olmos RA, van Leeuwen FW. Intraoperative laparoscopic fluorescence guidance to the sentinel lymph node in prostate cancer patients: clinical proof of concept of an integrated functional imaging approach using a multimodal tracer. Eur Urol. 2011;60:826–833. doi: 10.1016/j.eururo.2011.03.024. [DOI] [PubMed] [Google Scholar]
- 21.Messing EM, Manola J, Sarosdy M, Wilding G, Crawford ED, Trump D. Immediate hormonal therapy compared with observation after radical prostatectomy and pelvic lymphadenectomy in men with node-positive prostate cancer. N Engl J Med. 1999;341:1781–1788. doi: 10.1056/NEJM199912093412401. [DOI] [PubMed] [Google Scholar]
- 22.Joslyn SA, Konety BR. Impact of extent of lymphadenectomy on survival after radical prostatectomy for prostate cancer. Urology. 2006;68:121–125. doi: 10.1016/j.urology.2006.01.055. [DOI] [PubMed] [Google Scholar]
- 23.Passoni NM, Abdollah F, Suardi N, et al. Head-to-head comparison of lymph node density and number of positive lymph nodes in stratifying the outcome of patients with lymph node-positive prostate cancer submitted to radical prostatectomy and extended lymph node dissection. Urol Oncol. 2014;32:e21–e28. doi: 10.1016/j.urolonc.2012.10.009. [DOI] [PubMed] [Google Scholar]
- 24.Briganti A, Karnes JR, Da Pozzo LF, et al. Two positive nodes represent a significant cut-off value for cancer specific survival in patients with node positive prostate cancer: a new proposal based on a two-institution experience on 703 consecutive N+ patients treated with radical prostatectomy, extended pelvic lymph node dissection and adjuvant therapy. Eur Urol. 2009;55:261–270. doi: 10.1016/j.eururo.2008.09.043. [DOI] [PubMed] [Google Scholar]
- 25.Abdollah F, Suardi N, Cozzarini C, et al. Selecting the optimal candidate for adjuvant radiotherapy after radical prostatectomy for prostate cancer: a long-term survival analysis. Eur Urol. 2013;63:998–1008. doi: 10.1016/j.eururo.2012.10.036. [DOI] [PubMed] [Google Scholar]
- 26.Weingärtner K, Ramaswamy A, Bittinger A, Gerharz EW, Voge D, Riedmiller H. Anatomical basis for pelvic lymphadenectomy in prostate cancer: results of an autopsy study and implications for the clinic. J Urol. 1996;156:1969–1971. doi: 10.1016/s0022-5347(01)65406-5. [DOI] [PubMed] [Google Scholar]
- 27.Yee DS, Katz DJ, Godoy G, et al. Extended pelvic lymph node dissection in robotic-assisted radical prostatectomy: surgical technique and initial experience. Urology. 2010;75:1199–1204. doi: 10.1016/j.urology.2009.06.103. [DOI] [PubMed] [Google Scholar]
- 28.Mattei A, Fuechsel FG, Bhatta Dhar N, et al. The template of the primary lymphatic landing sites of the prostate should be revisited: results of a multimodality mapping study. Eur Urol. 2008;53:118–125. doi: 10.1016/j.eururo.2007.07.035. [DOI] [PubMed] [Google Scholar]
- 29.Wawroschek F, Vogt H, Weckermann D, Wagner T, Harzmann R. The sentinel lymph node concept in prostate cancer: first results of gamma probe-guided sentinel lymph node identification. Eur Urol. 1999;36:595–600. doi: 10.1159/000020054. [DOI] [PubMed] [Google Scholar]
- 30.Jeschke S, Beri A, Grull M, et al. Laparoscopic radioisotope-guided sentinel lymph node dissection in staging of prostate cancer. Eur Urol. 2008;53:126–132. doi: 10.1016/j.eururo.2007.03.064. [DOI] [PubMed] [Google Scholar]
- 31.Briganti A, Chun FK, Salonia A, et al. Complications and other surgical outcomes associated with extended pelvic lymphadenectomy in men with localized prostate cancer. Eur Urol. 2006;50:1006–1013. doi: 10.1016/j.eururo.2006.08.015. [DOI] [PubMed] [Google Scholar]
- 32.Weckermann D, Hamm M, Dorn R, Wagner T, Wawroschek F, Harzmann R. Sentinel lymph node dissection in prostate cancer. Experience after more than 800 interventions [in German] Urologe A. 2006;45:723–727. doi: 10.1007/s00120-006-1030-x. [DOI] [PubMed] [Google Scholar]
- 33.Jeschke S, Lusuardi L, Myatt A, Hruby S, Pirich C, Janetschek G. Visualisation of the lymph node pathway in real time by laparoscopic radioisotope- and fluorescence-guided sentinel lymph node dissection in prostate cancer staging. Urology. 2012;80:1080–1086. doi: 10.1016/j.urology.2012.05.050. [DOI] [PubMed] [Google Scholar]
- 34.Brouwer OR, Buckle T, Vermeeren L, et al. Comparing the hybrid fluorescent-radioactive tracer indocyanine green-99mTc-nanocolloid with 99mTc-nanocolloid for sentinel node identification: a validation study using lymphoscintigraphy and SPECT/CT. J Nucl Med. 2012;53:1034–1040. doi: 10.2967/jnumed.112.103127. [DOI] [PubMed] [Google Scholar]
- 35.Liss MA, Stroup SP, Qin Z, Hall DJ, Kane CJ, Vera DR. Robotic-assisted fluorescent-guided sentinel lymph node dissection in a preclinical model. Urology. In press. [Google Scholar]