Abstract
Objectives To determine and compare the diagnostic accuracy of serum natriuretic peptide levels (B type natriuretic peptide, N terminal probrain natriuretic peptide (NTproBNP), and mid-regional proatrial natriuretic peptide (MRproANP)) in people presenting with acute heart failure to acute care settings using thresholds recommended in the 2012 European Society of Cardiology guidelines for heart failure.
Design Systematic review and diagnostic meta-analysis.
Data sources Medline, Embase, Cochrane central register of controlled trials, Cochrane database of systematic reviews, database of abstracts of reviews of effects, NHS economic evaluation database, and Health Technology Assessment up to 28 January 2014, using combinations of subject headings and terms relating to heart failure and natriuretic peptides.
Eligibility criteria for selecting studies Eligible studies evaluated one or more natriuretic peptides (B type natriuretic peptide, NTproBNP, or MRproANP) in the diagnosis of acute heart failure against an acceptable reference standard in consecutive or randomly selected adults in an acute care setting. Studies were excluded if they did not present sufficient data to extract or calculate true positives, false positives, false negatives, and true negatives, or report age independent natriuretic peptide thresholds. Studies not available in English were also excluded.
Results 37 unique study cohorts described in 42 study reports were included, with a total of 48 test evaluations reporting 15 263 test results. At the lower recommended thresholds of 100 ng/L for B type natriuretic peptide and 300 ng/L for NTproBNP, the natriuretic peptides have sensitivities of 0.95 (95% confidence interval 0.93 to 0.96) and 0.99 (0.97 to 1.00) and negative predictive values of 0.94 (0.90 to 0.96) and 0.98 (0.89 to 1.0), respectively, for a diagnosis of acute heart failure. At the lower recommended threshold of 120 pmol/L, MRproANP has a sensitivity ranging from 0.95 (range 0.90-0.98) to 0.97 (0.95-0.98) and a negative predictive value ranging from 0.90 (0.80-0.96) to 0.97 (0.96-0.98). At higher thresholds the sensitivity declined progressively and specificity remained variable across the range of values. There was no statistically significant difference in diagnostic accuracy between plasma B type natriuretic peptide and NTproBNP.
Conclusions At the rule-out thresholds recommended in the 2012 European Society of Cardiology guidelines for heart failure, plasma B type natriuretic peptide, NTproBNP, and MRproANP have excellent ability to exclude acute heart failure. Specificity is variable, and so imaging to confirm a diagnosis of heart failure is required. There is no statistical difference between the diagnostic accuracy of plasma B type natriuretic peptide and NTproBNP. Introduction of natriuretic peptide measurement in the investigation of patients with suspected acute heart failure has the potential to allow rapid and accurate exclusion of the diagnosis.
Introduction
Making the correct diagnosis in patients with suspected acute heart failure is challenging, and confirmatory in only 40-50% of cases. Several studies have shown that when added to routine history, clinical examination, and conventional investigations (for example, chest radiography), measurement of plasma natriuretic peptide levels improves diagnostic accuracy, and has led to these markers being recommended in international guidelines for the diagnosis and management of heart failure.1 2 The 2012 European Society of Cardiology guidelines for heart failure endorsed specific age independent decision cut-offs for plasma B type natriuretic peptide (≤100 ng/L), N terminal probrain natriuretic peptide (NTproBNP, ≤300 ng/L), and mid-regional proatrial natriuretic peptide (MRproANP, ≤120 pmol/L) for the exclusion of acute heart failure based on consensus of expert opinion.2 3 Although natriuretic peptide levels have been used widely for the earlier diagnosis or exclusion of chronic heart failure in the outpatient setting, their use in the acute care setting has only partially been adopted, because their role has remained uncertain and they are not routinely available in emergency departments in the United Kingdom for rapid assessment of patients presenting with breathlessness. This lack of availability reflects lack of clarity on the diagnostic accuracy of natriuretic peptides in this setting. In particular, while the age independent cut-offs as recommended by the European Society of Cardiology are relatively easy to apply in clinical practice, they have not been evaluated by diagnostic meta-analysis. As part of the development process of a National Institute for Health and Care Excellence guideline on the management of acute heart failure we performed an up to date, diagnostic meta-analysis of the utility of plasma B type natriuretic peptide, NTproBNP, and MRproANP in acute and hospital based care settings at the thresholds recommended by the European Society of Cardiology guidelines.
Methods
Types of studies
We considered studies to be eligible if they evaluated one or more natriuretic peptides (B type natriuretic peptide, NTproBNP, or MRproANP) in the diagnosis of heart failure against an acceptable reference standard in a consecutive or randomly selected series of adults (age ≥18 years) in an acute care setting. The reference standard was the diagnosis of heart failure by retrospective review or the final hospital diagnosis. Studies were excluded if they did not present sufficient data to allow us to extract or calculate absolute numbers of true positives, false positives, false negatives, and true negatives or to report age independent natriuretic peptide thresholds. Studies were also excluded if they were not available in English.
For each natriuretic peptide, we grouped data according to prespecified age independent thresholds from the 2012 European Society of Cardiology guidelines for heart failure. Some studies contributed data to more than one threshold analysis per peptide. The ranges used were ≤100 ng/L, 100-500 ng/L, and >500 ng/L for B type natriuretic peptide; ≤300 ng/L, 300-1800 ng/L, and >1800 ng/L for NTproBNP; and ≤120 pmol/L and >120 pmol/L for MRproANP.
We excluded studies examining the use of natriuretic peptides in the diagnosis of heart failure in non-acute care settings, the use of urinary natriuretic peptides, screening for left or right ventricular dysfunction, and studies concerning the diagnostic accuracy of natriuretic peptides in pleural effusion of unknown cause.
Search strategies
For the search strategies we used a combination of subject headings and terms relating to the target condition of interest (heart failure) and the index tests (natriuretic peptides: B type natriuretic peptide, NTproBNP, and MRproANP). Using the search terms and strategies described in the supplementary file we searched Medline, Embase, Cochrane central register of controlled trials, Cochrane database of systematic reviews, database of abstracts of reviews of effects, NHS economic evaluation database, and Health Technology Assessment up to 28 January 2014.
Selection of studies
One author (ER) initially assessed the titles and then abstracts of papers identified by the search. Two authors (ER and KD) reviewed the full text of the remaining articles. Any discrepancy was resolved by discussion. Where agreement could not be reached, we consulted a third author (JM or AL). Excluded studies are listed in the online supplementary material.
Data extraction and management
Two authors (ER and KD) independently extracted a standard set of data, with discrepancies resolved by discussion. Where more than one type of assay for the same index test was used (for example, Abbott or Biosite BNP), the more conservative estimate of sensitivity was extracted and included in the review. For each comparison of index test at a particular threshold with a reference standard, we extracted data on the number of true positives, true negatives, false positives, and false negatives.
Assessment of methodological quality
Two authors (ER and KD) independently assessed the quality of each study using the QUADAS-II checklist (www.bris.ac.uk/quadas/quadas-2).
Statistical analysis and data synthesis
The comparisons made in this review can be considered in two parts. The first comparison was among studies using the same individual peptide (B type natriuretic peptide, NTpro-BNP, MRpro ANP) according to the three threshold categories. The second comparison was between different peptides at “equivalent” thresholds for ruling out heart failure, as specified in the 2012 European Society of Cardiology guidelines for heart failure. Comparative analyses were conducted across all included studies as well as within studies, with direct comparisons between tests with the same participants. Analyses were conducted in Review Manager version 5.3 and STATA SE version 12.
For each natriuretic peptide at the prespecified threshold, we plotted estimates of the paired observed sensitivities and specificities in forest plots and as average summary receiver operating characteristic (sROC) curves. These plots show the variation in accuracy between studies. Where adequate data were available we carried out diagnostic meta-analyses. To be able to pool data we required five or more studies for each threshold. We used the bivariate method modelled in Winbugs (Medical Research Council Biostatistics Unit) to pool test accuracy for the studies. The bivariate method uses logistic regression on the true positives, true negatives, false positives, and false negatives reported in the studies. We constructed sROCs and plotted confidence regions (using methods outlined by Novielli and colleagues4). The average operating point for each test was identified on each curve, and average sensitivities and specificities computed. Where insufficient data were available to estimate all variables, we simplified the sROC model by assuming a symmetrical shape to the sROC curve. We assessed the significance of the difference in test performance by using a likelihood ratio test comparing models with and without covariate terms for accuracy at equivalent thresholds.
Investigation of publication bias and heterogeneity
To assess for the possibility of publication bias for each peptide at each threshold, we constructed funnel plots and performed Deeks’ funnel plot asymmetry test, with a P value greater than 0.1 indicating no publication bias. We predefined heterogeneity as an I2 statistic greater than 50%, and calculated I2 for each analysis where there were sufficient studies (>5) for diagnostic meta-analysis. Where heterogeneity was shown, we investigated variation in sensitivity and specificity by adding to the meta-analysis models prespecified covariates indicating acute care setting of presentation, assay of natriuretic peptide used in the study cohort, prevalence of acute heart failure, and overall study quality. We did not carry out sensitivity analyses.
Results
The search identified 7007 papers, of which 6856 were excluded on the basis of the title and abstract. Full text articles were retrieved for 151 titles, of which 109 were excluded: non-diagnostic accuracy studies (n=47); non-acute care setting (n=33); systematic reviews (n=14), cross checked for includable references; not available in English (n=8); and unable to extract absolute numbers of true positives, false positives, false negatives, and true negatives (n=7). (See the supplementary file for the PRISMA flow diagram and table showing excluded studies.)
A total of 37 unique study cohorts described in 42 study reports were included in the review. In eight of the 37 study cohorts more than one test was evaluated. Thus a total of 48 test evaluations reported a total of 15 263 test results. The reference standard diagnosis of heart failure was a clinical diagnosis of a syndrome in which patients have typical symptoms (for example, dyspnoea and peripheral oedema) and signs (for example, raised jugular venous pressure and pulmonary crepitations) resulting from an abnormality of cardiac structure or function. Retrospective clinical review was the reference standard for 36 test evaluations, and discharge or final hospital diagnosis for 12. Table 1 shows the reference standards described in individual studies.
Table 1.
Study, setting | No (mean age) | Design | No of men/women | Prevalence (%) | Index test (assay) | Reference standard | Quality (QUADAS-II) |
---|---|---|---|---|---|---|---|
Fleischer 1997,5 acute admissions | 123 (68) | Prospective cohort | 69/54 | 43/123 (35) | BNP inhouse assay | Clinical diagnosis based on intent to treat heart failure with diuretics for 24 hours | Patient selection: high; index test: high; reference standard: high; flow and timing: low; overall: high |
Dao 2001,6 emergency department | 250 (63) | Cross sectional | 235/15 | 97/250 (39) | BNP Triage (Biosite, USA) | Retrospective review by two cardiologists | Patient selection: high; index test: low; reference standard: low; flow and timing: low; overall: high |
Logeart 2002,7 intensive care unit | 163 (71) | Cross sectional | 109/54 | 115/163 (71) | BNP Triage (Biosite, USA) | Retrospective review by two cardiologists and one pulmonologist | Patient selection: high; index test: low; reference standard: low; flow and timing: low; overall: high |
Maisel 2002,8 emergency department | 1586 (64) | Prospective cohort | 888/698 | 744/1586 (47) | BNP Triage (Biosite, USA) | Retrospective review by two cardiologists | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Villacorta 2002,9 emergency department | 70 (72) | Cross sectional | 33/37 | 36/70 (51) | BNP Triage (Biosite, USA) | Retrospective review by one cardiologist | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Lainchbury 2003,10 emergency department. Only BNP results extracted. NTproBNP from pooled results in Januzzi 200611 | 205 (70) | Prospective cohort | 100/105 | 70/205 (34) | BNP Triage (Biosite, USA) (+3 inhouse developed assays; not extracted in this analysis) | Retrospective review by two cardiologists | Patient selection: high; index test: low; reference standard: low; flow and timing: low; overall: high |
Davis 2004,12 emergency department | 52 (74) | Prospective cohort | 21/31 | 32/52 (62) | BNP inhouse assay | Retrospective review by committee of physicians | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Dokanish 2004,13 inpatients | 122 (56) | Cross sectional | 62/60 | 70/122 (57) | BNP Triage (Biosite, USA) | Retrospective review by one cardiologist | Patient selection: high; index test: low; reference standard: low; flow and timing: low; overall: high |
Barcase 2004,14 emergency department | 98 (65) | Prospective cohort | 100/0 | 57/98 (58) | BNP Triage (Biosite, USA) | Retrospective review by one cardiologist | Patient selection: low; index test: high; reference standard: high; flow and timing: low; overall: high |
Ray2004,15 emergency department (overlap with Ray 2005.23 Only BNP results extracted | 308 (80) | Cross sectional | 154/154 | 141/308 (46) | BNP Triage (Biosite, USA) | Retrospective review by two experts | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Ailbay 2005,16 emergency department | 160 (80.1) | Cross sectional | 76/84 | 60/160 (38) | BNP Triage (Biosite, USA), NTproBNP Elecsys (Roche, USA) | Retrospective review by two cardiologists | Patient selection: high; index test: low; reference standard: low; flow and timing: low; overall: high |
Arques 2005,17 acute referrals | 70 (NR) | Prospective cohort | 35/35 | 32/70 (46) | BNP Triage (Biosite, USA) | Retrospective review by two cardiologists and one pulmonologist | Patient selection: high; index test: low; reference standard: high; flow and timing: low; overall: high |
Chenevier-Gobeaux 2005,18 emergency department. Results without renal function stratification from Chenevier-Gobeaux 201019 | 378 (78) | Prospective cohort | 190/188 | 115/378 (30) | BNP Triage (Biosite, USA), NTproBNP Elecsys (Roche, USA), MRproANP LIA (B.R.A.H.M.S, Germany) | Consensus of two senior emergency department physicians | Patient selection: high; index test: low; reference standard: low; flow and timing: high; overall: high |
Mueller 2005,20 emergency department. MRproANP results from Gegenhuber 200621 | 251 (72.8) | Prospective cohort | 234/17 | 137/251 (55) | BNP Abbott Architecht (Abbott Diagnostics, Netherlands), NTproBNP Elecsys (Roche, USA), MRproANP LIA (B.R.A.H.M.S, Germany) | Retrospective review by one study investigator | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Parab 2005,22 emergency department | 70 (76.5) | Retrospective cohort | 24/46 | 47/70 (68) | BNP Triage (Biosite, USA) | Retrospective chart review | Patient selection: high; index test: low; reference standard: low; flow and timing: low; overall: high |
Ray2005,23 emergency department. Overlap with Ray 2004.15 Only NTproBNP results extracted | 202 (80) | Cross sectional | 100/102 | 88/202 (44) | NTproBNP Elecsys (Roche, USA) | Retrospective review by two experts | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Zaninotto 2005,24 emergency department | 122 (78) | Prospective cohort | 58/64 | 56/122 (46) | NTproBNP Elecsys (Roche, USA) | Diagnosis recorded at discharge on basis of clinical and instrumental investigations | Patient selection: low; index test: high; reference standard: high; flow and timing: low; overall: high |
Berdague 2006,25 emergency department | 254 (81) | Prospective cohort | 123/133 | 142/254 (56) | NTproBNP Elecsys (Roche, USA) | Retrospective review by two cardiologists | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Chung 2006,26 emergency department | 143 (79) | Prospective cohort | 63/80 | 72/143 (50) | BNP Triage (Biosite, USA) | Retrospective review by one cardiologist | Patient selection: low; index test: high; reference standard: high; flow and timing: low; overall: high |
Januzzi 2006,11 emergency department; comprising pooled data from Lainchbury 2003,10 Bayes-Genis 2004,27 and Januzzi 2005,28 and unpublished registry data | 1256 (68.3) | Pooled prospective trial data | 641/615 | 720/1256 (57) | NTproBNP Elecsys (Roche, USA) | Retrospective review utilising European society of cardiology guidelines. “Suitable for pooling across studies” | Patient selection: high; index test: low; reference standard: low; flow and timing: low; overall: high |
Sanz 2006,29 emergency department | 75 (75) | Prospective cohort | NR | 45/75 (60) | BNP Access (Beckman Coulter, USA) (+ BNP Advia (Bayer Diagnostics, USA) not extracted), NTproBNP Elecsys (Roche, USA) | Diagnosed according to symptoms and signs and electrocardiography, chest radiography, and in some cases echocardiography | Patient selection: high; index test: low; reference standard: high; flow and timing: low; overall: high |
Arques 2007,30 emergency department | 41 (NR) | Prospective cohort | 17/24 | 22/41 (54) | BNP Triage (Biosite, USA) | Retrospective review by two cardiologist and one respiratory physician | Patient selection: high; index test: low; reference standard: low; flow and timing: low |
Gorissen 2007,31 emergency department | 80 (74) | Retrospective cohort | 44/36 | 40/80 (50) | BNP Triage (Biosite, USA), NTproBNP Elecsys (Roche, USA) | Retrospective review by cardiologist and pulmonologist | Patient selection: high; index test: low; reference standard: low; flow and timing: high; overall: high |
Karmpaliotis 2007,32 intensive care unit | 74 (NR) | Prospective cohort | 45/35 | 23/74 (31) | BNP Triage (Biosite, USA) | Retrospective review by two intensivists | Patient selection: high; index test: low; reference standard: low; flow and timing: low; overall: high |
Gargani 2008,33 cardiology and pulmonary admissions | 149 (NR) | Prospective cohort | 98/51 | 122/149 (82) | NTproBNP Elecsys (Roche, USA) | Retrospective review by two cardiologists | Patient selection: high; index test: low; reference standard: low; flow and timing: low; overall: high |
Gruson 2008,34 emergency department | 137 (69) | Prospective cohort | 77/60 | 31/137 (23) | BNP Access (Beckman Coulter, USA), NTproBNP Elecsys (Roche, USA) | Based on clinical signs, chest radiography, echocardiography, and/or radionuclide angiography | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Behnes 2009,35 emergency department | 401 (67.4) | Prospective cohort | 205/196 | 122/401 (30) | NTproBNP Dimension Dade (Dade-Behring, USA) | Retrospective review by study physician | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Klemen 2009,36 prehospital emergency | 441 (59.1) | Prospective cohort | 271/170 | 238/441 (54) | NTproBNP Elecsys (Roche, USA) | Final hospital diagnosis confirmed by cardiologists and/or intensivists | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Nazarian 2009,37 emergency department | 145 (NR) | Prospective Cohort | NR | 64/145 (44) | NTproBNP Elecsys (Roche, USA) | Retrospective review by two cardiologists and one respiratory physician | Patient selection: low; index test: high; reference standard: high; flow and timing: low; overall: high |
Rogers 2009,38 emergency department | 740 (NR) | Prospective cohort | 399/341 | 368/740 (50) | BNP (5 sites Triage, Biosite, USA, 2 site Abbott, Netherlands) | Retrospective review by two cardiologists | Patient selection: high; index test: high; reference standard: high; flow and timing: high; overall: high |
Lokuge 2010,39 emergency department | 612 (74.5) | Retrospective cohort | 328/284 | 274/612 (45) | BNP Abbott Architecht (Abbott Diagnostics, Netherlands) | Retrospective review by one physician and one cardiologist | Patient selection: high; index test: low; reference standard: low; flow and timing: low; overall: high |
Maisel 2010,40 emergency department | 1641 (NR) | Prospective cohort | 859/782 | 568/1641 (39) | BNP Triage (Biosite, USA), MRproANP LIA (B.R.A.H.M.S, Germany) | Retrospective review by two cardiologists | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Potocki 2010,41 emergency department | 287 (77) | Prospective cohort | 149/138 | 154/287 (54) | NTproBNP Elecsys (Roche, USA), MRproANP LIA (B.R.A.H.M.S, Germany) | Retrospective review by two cardiologists | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Wang 2010,42 emergency department | 84 (73.5) | Prospective cohort | 40/44 | 49/84 (58) | BNP Abbott Architecht (Abbott Diagnostics, Netherlands) | Retrospective review by two cardiologists | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Blonde-Cynober 2011,43 inpatients | 64 (84.3) | Prospective cohort | 20/44 | 26/64 (41) | BNP Triage (Biosite, USA) | Retrospective review by one cardiologist and one geriatrician | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Prosen 2011,44 prehospital emergency | 218 (NR) | Prospective cohort | NR | 129/218 (59) | NTproBNP Elecsys (Roche, USA) | Final hospital diagnosis confirmed by cardiologists and or intensivists | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
Shaikh 2011,45 emergency department | 100 (61) | Cross sectional | 48/52 | 79/100 (79) | NTproBNP Elecsys (Roche, USA) | Cardiology discharge diagnosis | Patient selection: low; index test: high; reference standard: high; flow and timing: low; overall: high |
Eckstein 2012,46 emergency department. Overlap with Maisel 201040 data. Data only extracted for NTproBNP to avoid double counting for MRproANP | 632 (NR) | Prospective cohort | NR | 362/632 (57) | NTproBNP Elecsys (Roche, USA) | Retrospective review by two cardiologists | Patient selection: low; index test: low; reference standard: low; flow and timing: low; overall: low |
BNP=B type natriuretic peptide; NTproBNP=N terminal probrain natriuretic peptide; MRproANP=mid-regional proatrial natriuretic peptide; NR=not recorded.
The accuracy of B type natriuretic peptide was assessed in 26 study cohorts. In 19 cohorts (6950 participants) data were reported at the ≤100 ng/L threshold, in 20 cohorts (4543 participants) at the 100-500 ng/L threshold, and in four cohorts (283 participants) at the ≥500 ng/L threshold.
The accuracy of NTproBNP was assessed in 18 study cohorts. In 10 cohorts (3349 participants) data were reported at the ≤300 ng/L threshold, in 13 cohorts (3223 participants) at the 300-1800 ng/L threshold, and in three cohorts (840 participants) at the ≥1800 ng/L threshold.
The accuracy of MRproANP was assessed in four study cohorts. In two cohorts (1892 participants) data were reported at the ≤120 pmol/L threshold and in three cohorts (916 participants) at the >120 pmol/L threshold. Table 1 provides a summary of the studies assessing each natriuretic peptide.
Methodological quality of included studies
We used four quality categories (patient selection, reference standard, index test, and flow and timing) to evaluate the risk of bias and applicability of each study cohort and designated an overall high or low risk of bias for each category (see table 1). Just over 50% of the studies included a representative spectrum of participants attending acute care settings with symptoms suggestive of acute heart failure; most of the remaining studies had inappropriate patient exclusion criteria based on our prespecified patient cohort or had not adequately described the sampling methods. Around 65% of the studies reported blinding of the reference standard to the results of the index test, and around 70% reported blinding of the index test to the results of the reference standard. Only around 60% either explained any withdrawals or was clear that there were no withdrawals and had appropriate sequencing of tests.
B type natriuretic peptide
When diagnostic meta-analysis was conducted the pooled sensitivity, specificity, positive predictive value, and negative predictive value of B type natriuretic peptide at a threshold of ≤100 ng/L were 0.95 (95% confidence interval 0.93 to 0.96), 0.63 (0.52 to 0.73), 0.67 (0.63 to 0.75), and 0.94 (0.90 to 0.96), respectively. At a B type natriuretic peptide level of 100-500 ng/L, the pooled sensitivity, specificity, positive predictive value, and negative predictive value were 0.85 (0.81 to 0.88), 0.86 (0.79 to 0.91), 0.85 (0.78 to 0.90), and 0.86 (0.82 to 0.89), respectively. As only four study cohorts reported data for B type natriuretic peptide at a threshold of ≥500 ng/L, diagnostic meta-analysis was not performed and the reported sensitivity from the study cohorts ranged from 0.35 (range 0.17-0.56) to 0.83 (0.69-0.92) and the paired specificity from 0.78 (0.56-0.93) to 1.0 (0.91-1.0). At the lowest threshold (<100 ng/L) sensitivity was consistently high whereas specificity varied widely across all studies (0.26-0.94). As the threshold increased, sensitivity decreased (that is, more cases of heart failure would be missed) and specificity increased yet remained quite variable (fig 1). Figure 2 provides additional information, displaying the summary sensitivity and specificity points compared with the forest plots in figure 1. The summary point for the threshold of 100-500 ng/L is clearly lower in the sROC space compared with the <100 ng/L threshold, suggesting diagnoses of heart failure would be missed, although the specificity was higher.
N terminal probrain natriuretic peptide
When diagnostic meta-analysis was conducted, the pooled sensitivity, specificity, positive predictive value, and negative predictive value of NTproBNP at a threshold of ≤300 ng/L were 0.99 (95% confidence interval 0.97 to 1.00), 0.43 (0.26 to 0.62), 0.64 (0.57 to 0.73), and 0.98 (0.89 to 1.0), respectively; and at 300 to 1800 ng/L these variables were 0.90 (0.86 to 0.93), 0.76 (0.69 to 0.82), 0.80 (0.74 to 0.84), and 0.88 (0.82 to 0.92), respectively. As only three study cohorts reported data for NTproBNP at a threshold of ≥1800 ng/L, diagnostic meta-analysis was not performed and the reported sensitivity ranged from 0.67 (range 0.60-0.73) to 0.87 (0.81-0.92) and the paired specificity from 0.72 (0.63-0.80) to 0.95 (0.91-0.98). The pattern in figures 3 and 4 mirrors that of B type natriuretic peptide at different thresholds—that is, decreasing sensitivity and increasing specificity with increasing threshold. The summary points in figure 4 clearly indicate a decrease in mean sensitivity by threshold.
Mid-regional proatrial natriuretic peptide
As only four study cohorts reported data for MRproANP, diagnostic meta-analysis was not performed. At a threshold of ≤120 pmol/L the sensitivity of MRproANP ranged from 0.95 (range 0.90-0.98) to 0.97 (0.95-0.98) and the paired specificity ranged from 0.56 (0.47-0.65) to 0.60 (0.57-0.63). At a threshold of >120 pmol/L the sensitivity ranged from 0.84 (0.77-0.89) to 0.98 (0.94-1.00) and the paired specificity from 0.40 (0.34-0.46) to 0.84 (0.77-0.90). With data from only four study cohorts available, the pattern for MRproANP was less clear, with sensitivity remaining high across the two thresholds, although the specificity was variable (figs 5 and 6).
Comparisons between natriuretic peptides
After diagnostic meta-analysis was conducted, there was a clear overlap of the confidence regions for B type natriuretic peptide versus NTproBNP surrounding the pooled sensitivity and specificity. This overlap suggested no statistically significant difference between tests at the rule-out thresholds of ≤100 ng/L and ≤300 ng/L, respectively (P>0.05) (fig 7).
Using the upper and lower confidence limits of the sensitivity at the rule-out thresholds, the number of false negatives per 1000 were calculated assuming a prevalence ranging from 0.23 to 0.82 (the range in the included study cohorts). At a prevalence of 0.23 there were between 0 and 7 or 9 and 16 false negative diagnoses per 1000; and at a prevalence of 0.82 there were between 33 and 57 or 0 and 25 false negative diagnoses per 1000, if employing a B type natriuretic peptide strategy or an N terminal probrain natriuretic peptide strategy, respectively.
Investigations of publication bias and heterogeneity
Deeks’ funnel plot asymmetry test revealed no evidence of publication bias for any peptide at any threshold (see supplementary file). Table 2 presents the I2 statistics for each peptide at each threshold. I2 statistics were, as expected in diagnostic meta-analyses, universally more than 50%, owing to differences in patients’ underlying diagnoses and comorbidities. Heterogeneity investigations were undertaken to test for differences in natriuretic peptide performance only where sufficient (≥5) study cohorts existed to perform diagnostic meta-analysis. The only significant difference was for NTproBNP ≤300ng/L; when adding prevalence differences into the model the specificity was significantly higher at 0.93 (95% confidence interval 0.84 to 0.97, P<0.01). No other significant difference in sensitivity or specificity was noted for all other covariates for all peptides at each studied threshold. Table 3 shows the results.
Table 2.
Natriuretic peptide (threshold) | No of studies | No | No of cases | Sensitivity % | Specificity % | Positive predictive value | Negative predictive value | I2 (%) |
---|---|---|---|---|---|---|---|---|
B type natriuretic peptide: | ||||||||
≤100 ng/L | 19 | 6950 | 3049 | 0.95 (0.93 to 0.96) | 0.63 (0.52 to 0.73) | 0.67 (0.63 to 0.75) | 0.94 (0.90 to 0.96) | 98 |
100-500 ng/L | 20 | 4543 | 2160 | 0.85 (0.81 to 0.88) | 0.86 (0.79 to 0.91) | 0.85 (0.78 to 0.90) | 0.86 (0.82 to 0.89) | 97 |
≥500 ng/L | 4 | 283 | 145 | 0.35 (0.17-0.56) to 0.83 (0.69-0.92)* | 0.78 (0.56-0.93) to 1.00 (0.91-1.00)* | 0.89 (0.75-0.96) to 1.0 (0.63-1.0)* | 0.55 (0.69-0.80) to 0.69 (0.48-0.84)* | — |
N terminal probrain natriuretic peptide: | ||||||||
≤300 ng/L | 10 | 3349 | 1695 | 0.99 (0.97 to 1.00) | 0.43 (0.26 to 0.62) | 0.64 (0.57 to 0.73) | 0.98 (0.89 to 1.0) | 94 |
300-1800 ng/L | 13 | 3223 | 1652 | 0.90 (0.86 to 0.93) | 0.76 (0.69 to 0.82) | 0.80 (0.74 to 0.84) | 0.88 (0.82 to 0.92) | 97 |
≥1800 ng/L | 3 | 840 | 444 | 0.67 (0.60-0.73) to 0.87 (0.81-0.92)* | 0.72 (0.63-0.80) to 0.95 (0.91-0.98)* | 0.80 (0.73-0.86) to 0.94 (0.89-0.97)* | 0.71 (0.65-0.76) to 0.82 (0.73-0.89)* | — |
Mid-regional proatrial natriuretic peptide: | ||||||||
≤120 pmol/L | 2 | 1892 | 705 | 0.95 (0.90-0.98) to 0.97 (0.95-0.98)* | 0.56 (0.47-0.65) to 0.60 (0.57-0.63)* | 0.56 (0.53-0.59) to 0.72 (0.65-0.79)* | 0.90 (0.80-0.96) to 0.97 (0.96-0.98)* | — |
>120 pmol/L | 3 | 916 | 406 | 0.84 (0.77-0.89) to 0.98 (0.94-1.00)* | 0.40 (0.34-0.46) to 0.84 (0.77-0.90)* | 0.41 (0.35-0.47) to 0.86 (0.79-0.91)* | 0.82 (0.74-0.88) to 0.98 (0.93-1.00)* | — |
*A sensitivity or specificity range is given where there were insufficient number of studies to conduct diagnostic meta-analysis and generate a pooled sensitivity and specificity value. Table 1 shows the setting of each study and assay used.
Table 3.
Variables | Setting | Assay | Prevalence | Overall study quality |
---|---|---|---|---|
B type natriuretic peptide | ||||
≤100 ng/L: | ||||
Sensitivity (95% CI) | 0.95 (0.91 to 0.97) | 0.94 (0.91 to 0.96) | 0.96 (0.92 to 0.98) | 0.92 (0.84 to 0.96) |
P value | 0.89 | 0.6 | 0.5 | 0.13 |
Specificity (95% CI) | 0.56 (0.38 to 0.72) | 0.66 (0.49 to 0.79) | 0.62 (0.36 to 0.83) | 0.69 (0.43 to 0.87) |
P value | 0.51 | 0.76 | 0.96 | 0.64 |
100-500 ng/L: | ||||
Sensitivity (95% CI) | 0.87 (0.82 to 0.91) | 0.83 (0.77 to 0.88) | 0.82 (0.71 to 0.90) | 0.80 (0.68 to 0.88) |
P value | 0.37 | 0.68 | 0.62 | 0.29 |
Specificity (95% CI) | 0.81 (0.69 to 0.89) | 0.90 (0.81 to 0.95) | 0.89 (0.73 to 0.96) | 0.92 (0.78 to 0.97) |
P value | 0.38 | 0.45 | 0.65 | 0.36 |
N terminal probrain natriuretic peptide | ||||
≤300 ng/L: | ||||
Sensitivity (95% CI) | 0.99 (0.97 to 0.99) | 0.96 (0.77 to 0.99) | 0.98 (0.93 to 1.00) | 0.98 (0.90 to 1.00) |
P value | 0.97 | 0.21 | 0.81 | 0.56 |
Specificity (95% CI) | 0.77 (0.57 to 0.89) | 0.42 (0.06 to 0.89) | 0.93 (0.84 to 0.97) | 0.56 (0.15 to 0.90) |
P value | 0.53 | 0.37 | <0.01* | 058 |
N terminal probrain natriuretic peptide | ||||
300-1800 ng/L: | ||||
Sensitivity (95% CI) | 0.90 (0.85 to 0.94) | 0.92 (0.72 to 0.98) | 0.93 (0.84 to 0.97) | 0.91 (0.81 to 0.96) |
P value | 0.91 | 0.75 | 0.46 | 0.82 |
Specificity (95% CI) | 0.78 (0.70 to 0.85) | 0.58 (0.30 to 0.82) | 0.84 (0.71 to 0.92) | 0.78 (0.62 to 0.88) |
P value | 0.67 | 0.17 | 0.22 | 0.83 |
Discussion
This meta-analysis of the diagnostic accuracy of natriuretic peptide use was performed to inform recommendations within the new National Institute for Health and Care Excellence guideline for the diagnosis and management of people with suspected heart failure in the acute care setting. It is the largest meta-analysis of the use of natriuretic peptides specifically in the acute care setting, and the first to specifically investigate and compare the different natriuretic peptides at the cut-off thresholds defined within the 2012 European Society of Cardiology guidelines for heart failure for the diagnosis and exclusion of acute heart failure.2 Our results show that both B type natriuretic peptide and N terminal probrain natriuretic peptide (NTproBNP) have excellent ability to exclude the diagnosis of acute heart failure at their respective lower cut-off thresholds, with sensitivities approaching 1 and will therefore miss few, if any, cases of possible acute heart failure when used as a rule-out test. Mid-regional proatrial natriuretic peptide (MRproANP) at a threshold of <120 pmol/L also has a sensitivity close to 1, but there are too few suitable studies to date with which to perform a meta-analysis, and the investigation is not yet widely available as a clinical test. The sensitivity of B type natriuretic peptide, NTproBNP, and MRproANP for the diagnosis of acute heart failure at thresholds above this lower cut-off is only modest. Specificity is also relatively low (although it increases with increasing natriuretic peptide value), thus confirmatory testing by cardiac imaging is required.
The diagnosis of heart failure is often challenging: the symptoms and signs may be non-specific and may occur in other non-cardiac diseases. The mortality from acute heart failure remains high, at approximately 25% over one year,47 and this may be reduced by prompt diagnosis and treatment. The early use of a natriuretic peptide test to rule out acute heart failure, at the diagnostic thresholds evaluated in this meta-analysis, can reliably exclude heart failure and allow more rapid investigation of other potential causes for a patient’s symptoms. A negative test result may reduce or obviate the need to proceed to echocardiography or other cardiac imaging, allowing more efficient use of resources. In a similar fashion, in patients where the clinical assessment is difficult, the ability to rapidly raise the suspicion of acute heart failure when the result for natriuretic peptide is above the cut-off, will allow targeted, rapid investigation to confirm or refute the diagnosis. Earlier confirmation of the diagnosis of heart failure may facilitate more rapid initiation of specific treatment, potentially shortening hospital stay and reducing mortality.48
When B type natriuretic peptide was compared with NTproBNP, there was no statistically significant difference in their diagnostic ability at the rule-out thresholds examined. When converted to absolute patient numbers the use of B type natriuretic peptide rather than NTproBNP in an acute care setting potentially increased the false negative test results by between 8 and 31 more people per 1000 people (assuming a prevalence ranging from 0.23 to 0.82, the range in the included study cohorts). Sensitivity was similar and specificity only modest for both natriuretic peptides in the low to intermediate ranges of measured values. Therefore it is important that for values measured above the rule-out thresholds, the information is correlated with clinical and imaging assessment to confirm a diagnosis of heart failure and to exclude non-cardiac causes of an increased natriuretic peptide level (such as pulmonary embolus, sepsis, or renal failure).3 Similarly, once heart failure is thought to be likely because of clinical and natriuretic peptide evidence, further assessment (generally with echocardiography) is required to confirm the diagnosis and inform future management.
As with any test, the pretest probability is important and the result must be interpreted in the clinical context. If the clinical scenario is strongly suggestive of heart failure or, conversely, points towards an alternative diagnosis, there is no need to perform the assay for diagnostic purposes. For example, in a patient in whom dyspnoea is associated with a known cause, such as an adult presenting with trauma, measurement of the natriuretic peptide level is not needed.
In the United Kingdom the availability and use of natriuretic peptides is patchy and tests are not routinely available in acute care settings, despite accumulating evidence and national guidelines advocating their use.4 The barriers to introduction and use have not been reported but we speculate them to include perceived excessive additional cost, a perceived lack of additional diagnostic value, or uncertainty as to which natriuretic peptide to use and their relative merits.
A previous meta-analysis comparing B type natriuretic peptide with NTproBNP in the setting of acute heart failure only evaluated studies that compared paired sampling of both natriuretic peptides.49 Therefore, although diagnostic accuracy data were reported for each natriuretic peptide, not all relevant studies were included. However, no significant difference was found between B type natriuretic peptide and NTproBNP, which agrees with our findings. Worster and colleagues50 performed a meta-analysis of nine studies (six for B type natriuretic peptide and three for NTproBNP), published during or before 2004, evaluating the use of natriuretic peptides in acute care settings for the diagnosis of dyspnoea. Worster and colleagues also reported no difference between B type natriuretic peptide and NTproBNP, with similarly high diagnostic sensitivity and modest specificity. However, our analysis included a significantly larger numbers of studies, was not limited to dyspnoea, as people may present acutely with several different symptoms, and evaluated the accuracy at specific cut-off points to inform current clinical practice. A meta-analysis of MRproANP in the evaluation of dyspnoea in the emergency department51 showed a diagnostic pooled sensitivity of 0.90 (95% confidence interval 0.88 to 0.92) and pooled specificity of 0.68 (0.66 to 0.70) for the diagnosis of heart failure. However, our specific analysis of age independent data using the suggested rule-out threshold of <120 pmol/L gives a higher sensitivity of 0.95 (0.90 to 0.98) and paired specificity of 0.56 (0.47 to 0.65), suggesting that measurement of MRproANP may also be a valuable rule-out test for heart failure. Whether or not the test offers any other specific additional advantage remains to be determined.
The exhaustive meta-analysis performed shows that both B type natriuretic peptide and NTproBNP have similar, excellent negative predictive value. Therefore, whichever natriuretic peptide is available locally can be used reliably. No statistically significant differences were detected for their use within a specific care setting or by type of assay used (point of care or laboratory test).
Limitations of this study
The diagnostic values and cut-off thresholds for use of natriuretic peptides in people with suspected heart failure in the outpatient setting are different—associated with different (generally reduced) sensitivity and specificity—and so the results presented here are only applicable to patients presenting acutely. We have examined age independent cut-off values to validate the recommendations of the European Society of Cardiology guideline and to allow ease of introduction in acute clinical settings. A negative test result remains reassuring at any age, and the impact of factors affecting the serum level of natriuretic peptide (sex, age, body mass index) is less pronounced in acute heart failure than in chronic heart failure. The level of serum natriuretic peptide may increase with age, reducing the specificity in some groups, but this will not affect sensitivity.
Most studies in this review were performed within the emergency department, but we also included studies in other acute settings if natriuretic peptide was being used to differentiate heart failure from other diagnoses. As diagnostic thresholds vary depending on clinical characteristics, this may limit applicability in some settings. Studies in patients after cardiac surgery were specifically excluded and in studies with a higher previous risk or prevalence of acute heart failure the negative predictive value and sensitivity would tend to be lower.
In most studies the ideal diagnostic test was taken as a retrospective synthesis of clinical and imaging data, but was heterogeneous between studies. This is not likely to have affected the sensitivity results to any major degree but may account partly for variability in reported specificity. An individual patient meta-analysis would be technically possible to address this research question, but it is unlikely to expand further on the current review owing to the observed high sensitivity and negative predictive values calculated in an overall population of widely varying prevalence.
In this analysis we did not examine the role of natriuretic peptide use in guiding treatment or in informing prognosis in this setting. Although B type natriuretic peptide and NTproBNP are routinely available in hospital laboratories, MRproANP remains primarily a research tool.
Conclusions
The use of NTproBNP and B type natriuretic peptide at the rule-out threshold recommended by the recent European Society of Cardiology guidelines on heart failure provides excellent ability to exclude acute heart failure in the acute setting with reassuringly high sensitivity. The specificity is modest at all but the highest values of natriuretic peptide, therefore confirmatory testing by cardiac imaging is required in patients with positive test results. Use of natriuretic peptide may allow the streamlining of investigation, potentially leading to cost savings through removing or reducing the need for echocardiography in patients with natriuretic peptide levels below the cut-off threshold or by facilitating more rapid investigation of non-cardiac disease.
What is already known on this topic
Acute heart failure is the commonest cause of hospital admission in the United Kingdom in people aged over 65 years, and mortality remains high
Diagnosis of acute heart failure is often difficult and the measurement of serum natriuretic peptides in the acute setting may be useful, but has not been widely adopted in the United Kingdom
The 2012 European Society of Cardiology (ESC) guidelines for heart failure suggested rule-out thresholds for natriuretic peptides in the acute setting, but the diagnostic accuracy at these thresholds is not known
What this study adds
At the rule-out thresholds recommended in the 2012 ESC guidelines for heart failure, B type natriuretic peptide, N terminal probrain natriuretic peptide, and mid-regional proatrial natriuretic peptide have excellent ability to exclude acute heart failure and miss few cases
The specificity of the natriuretic peptides is modest and variable, and therefore confirmatory diagnostic testing by cardiac imaging is required in the case of positive results
The addition of testing for serum natriuretic peptides to acute care settings in patients with suspected heart failure has the potential to accurately streamline investigation and improve the early detection of heart failure
For their help in the preparation of this work we thank: Peter Bolton, Jane Butler, Amelia Ch’ng, Jill Cobb, Alice Ferns, Edward Griffin, Lina Gulhane, Suzanna Hardman, Nicholas Ioannou, Christopher Jones, Jason Kendall, Jayne Masters, Tanzeem Raza, and Gill Ritchie.
Contributors: ER and AJL are joint first authors. ER and KD performed the initial sift of papers and meta-analysis with additional assistance from AJL and JM. All authors discussed and critically appraised the data as part of the NICE guideline development group on acute heart failure. AJL, JJVMcM, MRC, AA-M, and JM decided to prepare the work for publication. ER and AJL wrote the first draft and all authors contributed critically to subsequent revisions. AJL and JM are the guarantors. The funder had no role in the study design; data collection, analysis, and interpretation; writing of the report; or the decision to submit for publication. The researchers were independent from the funder. All authors had full access to all the data and take responsibility for the integrity and accuracy of the data analysis.
Funding: The review was commissioned by the National Institute of Health and Care Excellence as part of work to formulate national guidance on the diagnosis and management of acute heart failure.
Competing interests: All authors have completed the ICMJE uniform disclosure form at www.icmje.org/coi_disclosure.pdf (available on request from the corresponding author) and declare: MRC’s salary was supported by the National Institute for Health Research Cardiovascular Biomedical Research Unit at the Royal Brompton Hospital, London but no authors have support from any company for the submitted work; MRC has received honorariums within the past three years from Roche Diagnostics for lecturing on the use of natriuretic peptides in the diagnosis of heart failure, no other author has a relationship with a company that might have an interest in the submitted work in the previous three years; no other relationships or activities that could appear to have influenced the submitted work.
Ethical approval: Not required.
Data sharing: No additional data available.
Transparency: The lead authors (AJL and JM) had final responsibility for the decision to submit for publication and affirm that the manuscript is an honest, accurate, and transparent account of the study being reported; that no important aspects of the study have been omitted; and that any discrepancies from the study as planned have been explained.
Cite this as: BMJ 2015;350:h910
Web Extra. Extra material supplied by the author
References
- 1.Yancy CW, Jessup M, Bozkurt B, Butler J, Casey DE, Drazner M, et al. ACCF/AHA guideline for the management of heart failure: a report of the American College of Cardiology Foundation/American Heart Association Task Force on practice guidelines Circulation 2013;128:e240-327. [DOI] [PubMed] [Google Scholar]
- 2.McMurray JJV, Adamopoulos S, Anker SD, Auricchio A, Bohm M, Dickstein K, et al. ESC guidelines for the diagnosis and treatment of acute and chronic heart failure 2012: The Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association (HFA) of the ESC. Eur J Heart Fail 2012;14:803-69. [DOI] [PubMed] [Google Scholar]
- 3.Thygesen K1, Mair J, Mueller C, Huber K, Weber M, Plebani M, et al. Recommendations for the use of natriuretic peptides in acute cardiac care: a position statement from the Study Group on Biomarkers in Cardiology of the ESC Working Group on Acute Cardiac Care Eur Heart J 2012;33:2001-6. [DOI] [PubMed] [Google Scholar]
- 4.Novielli N, Cooper NJ, Abrams KR, Sutton AJ. How is evidence on test performance synthesized for economic decision models of diagnostic tests? A systematic appraisal of Health Technology Assessments in the UK since 1997. Value Health 2010;13:952-7. [DOI] [PubMed] [Google Scholar]
- 5.Fleischer D, Espiner EA, Yandle TG, Livesey JH, Billings J, Town I, et al. Rapid assay of plasma brain natriuretic peptide in the assessment of acute dyspnoea. N Z Med J 1997;110:71-4. [PubMed] [Google Scholar]
- 6.Dao Q, Krishnaswamy P, Kazanegra R, Harrison A, Amirnovin R, Lenert L, et al. Utility of B-type natriuretic peptide in the diagnosis of congestive heart failure in an urgent-care setting. J Am Coll Cardiol 2001;37:379-85. [DOI] [PubMed] [Google Scholar]
- 7.Logeart D, Saudubray C, Beyne P, Thabut G, Ennezat PV, Chavelas C, et al. Comparative value of Doppler echocardiography and B-type natriuretic peptide assay in the etiologic diagnosis of acute dyspnea. J Am Coll Cardiol 2002;40:1794-800. [DOI] [PubMed] [Google Scholar]
- 8.Maisel AS, Krishnaswamy P, Nowak RM, McCord J, Hollander JE, Duc P, et al. Rapid measurement of B-type natriuretic peptide in the emergency diagnosis of heart failure. N Engl J Med 2002;347:161-7. [DOI] [PubMed] [Google Scholar]
- 9.Villacorta H, Duarte A, Duarte NM, Carrano A, Mesquita ET, Dohmann HJ, et al. The role of B-type natriuretic peptide in the diagnosis of congestive heart failure in patients presenting to an emergency department with dyspnea. Arq Bras Cardiol 2002;79:569-72. [DOI] [PubMed] [Google Scholar]
- 10.Lainchbury JG, Campbell E, Frampton CM, Yandle TG, Nicholls MG, Richards AM. Brain natriuretic peptide and n-terminal brain natriuretic peptide in the diagnosis of heart failure in patients with acute shortness of breath. J Am Coll Cardiol 2003;42:728-35. [DOI] [PubMed] [Google Scholar]
- 11.Januzzi JL, van Kimmenade R, Lainchbury J, Bayes-Genis A, Ordonez-Llanos J, Santalo-Bel M, et al. NT-proBNP testing for diagnosis and short-term prognosis in acute destabilized heart failure: an international pooled analysis of 1256 patients: the International Collaborative of NT-proBNP Study. Eur Heart J 2006;27:330-7. [DOI] [PubMed] [Google Scholar]
- 12.Davis M, Espiner E, Richards G, Billings J, Town I, Neill A, et al. Plasma brain natriuretic peptide in assessment of acute dyspnoea. Lancet 1994;343:440-4. [DOI] [PubMed] [Google Scholar]
- 13.Dokainish H, Zoghbi WA, Lakkis NM, Quinones MA, Nagueh SF. Comparative accuracy of B-type natriuretic peptide and tissue Doppler echocardiography in the diagnosis of congestive heart failure. Am J Cardiol 2004;93:1130-5. [DOI] [PubMed] [Google Scholar]
- 14.Barcarse E, Kazanegra R, Chen A, Chiu A, Clopton P, Maisel A. Combination of B-type natriuretic peptide levels and non-invasive hemodynamic parameters in diagnosing congestive heart failure in the emergency department. Congest Heart Fail 2004;10:171-6. [DOI] [PubMed] [Google Scholar]
- 15.Ray P, Arthaud M, Lefort Y, Birolleau S, Beigelman C, Riou B, et al. Usefulness of B-type natriuretic peptide in elderly patients with acute dyspnea. Intensive Care Med 2004;30:2230-6. [DOI] [PubMed] [Google Scholar]
- 16.Alibay Y, Beauchet A, El Mahmoud R Schmitta C, Brun-Neyd D, M Benoite, et al. Plasma N-terminal pro-brain natriuretic peptide and brain natriuretic peptide in assessment of acute dyspnea. Biomed Pharmacother 2005;59:20-4. [DOI] [PubMed] [Google Scholar]
- 17.Arques S, Roux E, Sbragia P, Gelisse R, Ambrosi P, Pieri B, et al. Comparative accuracy of color M-mode and tissue Doppler echocardiography in the emergency diagnosis of congestive heart failure in chronic hypertensive patients with normal left ventricular ejection fraction. Am J Cardiol 2005;96:1456-9. [DOI] [PubMed] [Google Scholar]
- 18.Chenevier-Gobeaux C, Claessens YE, Voyer S, Desmoulins D, Ekindjian OG. Influence of renal function on N-terminal pro-brain natriuretic peptide (NT-proBNP) in patients admitted for dyspnoea in the Emergency Department: comparison with brain natriuretic peptide (BNP). Clin Chim Acta 2005;361:167-75. [DOI] [PubMed] [Google Scholar]
- 19.Chenevier-Gobeaux C, Guerin S, Andre S, Ray P, Cynober L, Gestin S, et al. Midregional pro-atrial natriuretic peptide for the diagnosis of cardiac-related dyspnea according to renal function in the emergency department: a comparison with B-type natriuretic peptide (BNP) and N-terminal proBNP. Clin Chem 2010;56:1708-17. [DOI] [PubMed] [Google Scholar]
- 20.Mueller T, Gegenhuber A, Poelz W, Haltmayer M. Diagnostic accuracy of B type natriuretic peptide and amino terminal proBNP in the emergency diagnosis of heart failure. Heart 2005;91:606-12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Gegenhuber A, Struck J, Poelz W, Pacher R, Morgenthaler NG, Bergmann A, et al. Midregional pro-A-type natriuretic peptide measurements for diagnosis of acute destabilized heart failure in short-of-breath patients: comparison with B-type natriuretic peptide (BNP) and amino-terminal proBNP. Clin Chem 2006;52:827-31. [DOI] [PubMed] [Google Scholar]
- 22.Parab R, Vasudevan A, Brensilver J, Gitler B. Utility of brain natriuretic peptide as a diagnostic tool for congestive heart failure in the elderly. Crit Pathw Cardiol 2005;4:140-4. [DOI] [PubMed] [Google Scholar]
- 23.Ray P, Arthaud M, Birolleau S, Isnard R, Lefort Y, Boddaert J, et al. Comparison of brain natriuretic peptide and probrain natriuretic peptide in the diagnosis of cardiogenic pulmonary edema in patients aged 65 and older. J Am Geriatr Soc 2005;53:643-8. [DOI] [PubMed] [Google Scholar]
- 24.Zaninotto M, Mion M, Altinier S, Pastorello M, Rocco S, Tosato F, et al. NT-proBNP in the differential diagnosis of acute dyspnea in the emergency department. Clin Biochem 2005;38:1041-4. [DOI] [PubMed] [Google Scholar]
- 25.Berdague P, Caffin PY, Barazer I, Vergnes C, Sedighian S, Letrillard S, et al. Use of N-terminal prohormone brain natriuretic peptide assay for etiologic diagnosis of acute dyspnea in elderly patients. Am Heart J 2006;151:690-8. [DOI] [PubMed] [Google Scholar]
- 26.Chung T, Sindone A, Foo F, Dwyer A, Paoloni R, Janu MR, et al. Influence of history of heart failure on diagnostic performance and utility of B-type natriuretic peptide testing for acute dyspnea in the emergency department. Am Heart J 2006;152:949-55. [DOI] [PubMed] [Google Scholar]
- 27.Bayes-Genis A, Santalo-Bel M, Zapico-Muniz E, López L, Cotes C, Bellido J, et al. N-terminal probrain natriuretic peptide (NT-proBNP) in the emergency diagnosis and in-hospital monitoring of patients with dyspnoea and ventricular dysfunction. Eur J Heart Fail 2004;6:301-8. [DOI] [PubMed] [Google Scholar]
- 28.Januzzi JLJ, Camargo CA, Anwaruddin S, Baggish AL, Chen AA, Krauser DG, et al. The N-terminal Pro-BNP investigation of dyspnea in the emergency department (PRIDE) study. Am J Cardiol 2005;95:948-54. [DOI] [PubMed] [Google Scholar]
- 29.Sanz MP, Borque L, Rus A, Vicente B, Ramirez Y, Lasa L. Comparison of BNP and NT-proBNP assays in the approach to the emergency diagnosis of acute dyspnea. J Clin Lab Anal 2006;20:227-32. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Arques S, Roux E, Sbragia P, Pieri B, Gelisse R, Luccioni R, et al. Usefulness of bedside tissue Doppler echocardiography and B-type natriuretic peptide (BNP) in differentiating congestive heart failure from noncardiac cause of acute dyspnea in elderly patients with a normal left ventricular ejection fraction and permanent, nonvalvular atrial fibrillation: insights from a prospective, monocenter study. Echocardiography 2007;24:499-507. [DOI] [PubMed] [Google Scholar]
- 31.Gorissen C, Baumgarten R, de Groot M, van Haren E, Kragten H, Leers M. Analytical and clinical performance of three natriuretic peptide tests in the emergency room. Clin Chem Lab Med 2007;45:678-84. [DOI] [PubMed] [Google Scholar]
- 32.Karmpaliotis D, Kirtane AJ, Ruisi CP, Polonsky T, Malhotra A, Talmor D, et al. Diagnostic and prognostic utility of brain natriuretic Peptide in subjects admitted to the ICU with hypoxic respiratory failure due to noncardiogenic and cardiogenic pulmonary edema. Chest 2007;131:964-71. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Gargani L, Frassi F, Soldati G, Tesorio P, Gheorghiade M, Picano E. Ultrasound lung comets for the differential diagnosis of acute cardiogenic dyspnoea: a comparison with natriuretic peptides. Eur J Heart Fail 2008;10:70-7. [DOI] [PubMed] [Google Scholar]
- 34.Gruson D, Rousseau MF, Ahn S, Van Linden F, Thys F, Ketelslegers JM, et al. Accuracy of N-terminal-pro-atrial natriuretic peptide in patients admitted to emergency department. Scand J Clin Lab Invest 2008;68:410-4. [DOI] [PubMed] [Google Scholar]
- 35.Behnes M, Brueckmann M, Ahmad-Nejad P, Lang S, Wolpert C, Elmas E, et al. Diagnostic performance and cost effectiveness of measurements of plasma N-terminal pro brain natriuretic peptide in patients presenting with acute dyspnea or peripheral edema. Int J Cardiol 2009;135:165-74. [DOI] [PubMed] [Google Scholar]
- 36.Klemen P, Golub M, Grmec S. Combination of quantitative capnometry, N-terminal pro-brain natriuretic peptide, and clinical assessment in differentiating acute heart failure from pulmonary disease as cause of acute dyspnea in pre-hospital emergency setting: study of diagnostic accuracy. Croat Med J 2009;50:133-42. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Nazerian P, Vanni S, Zanobetti M, Polidori G, Pepe G, Federico R, et al. Diagnostic accuracy of emergency Doppler echocardiography for identification of acute left ventricular heart failure in patients with acute dyspnea: comparison with Boston criteria and N-terminal prohormone brain natriuretic peptide. Acad Emerg Med 2010;17:18-26. [DOI] [PubMed] [Google Scholar]
- 38.Kevin Rogers R, Stehlik J, Stoddard GJ, Greene T, Collins SP, Peacock WF, et al. Adjusting for clinical covariates improves the ability of B-type natriuretic peptide to distinguish cardiac from non-cardiac dyspnoea: a sub-study of HEARD-IT. Eur J Heart Fail 2009;11:1043-9. [DOI] [PubMed] [Google Scholar]
- 39.Lokuge A, Lam L, Cameron P, Krum H, de Villiers S, Bystrzycki A, et al. B-type natriuretic peptide testing and the accuracy of heart failure diagnosis in the emergency department. Circ Heart Fail 2010;3:104-10. [DOI] [PubMed] [Google Scholar]
- 40.Maisel A, Mueller C, Nowak R, Peacock WF, Landsberg JW, Ponikowski P, et al. Mid-region pro-hormone markers for diagnosis and prognosis in acute dyspnea: results from the BACH (Biomarkers in Acute Heart Failure) trial. J Am Coll Cardiol 2010;55:2062-76. [DOI] [PubMed] [Google Scholar]
- 41.Potocki M, Breidthardt T, Reichlin T, Hartwiger S, Morgenthaler NG, Bergmann A, et al. Comparison of midregional pro-atrial natriuretic peptide with N-terminal pro-B-type natriuretic peptide in the diagnosis of heart failure. J Intern Med 2010;267:119-29. [DOI] [PubMed] [Google Scholar]
- 42.Wang HK, Tsai MS, Chang JH, Wang TD, Chen WJ, Huang CH. Cardiac ultrasound helps for differentiating the causes of acute dyspnea with available B-type natriuretic peptide tests. Am J Emerg Med 2010;28:987-93. [DOI] [PubMed] [Google Scholar]
- 43.Blonde-Cynober F, Morineau G, Estrugo B, Fillie E, Aussel C, Vincent J-P. Diagnostic and prognostic value of brain natriuretic peptide (BNP) concentrations in very elderly heart disease patients: Specific geriatric cut-off and impacts of age, gender, renal dysfunction, and nutritional status. Arch Gerontol Geriatr 2011;52:106-10. [DOI] [PubMed] [Google Scholar]
- 44.Prosen G, Klemen P, Strnad M, Grmec S. Combination of lung ultrasound (a comet-tail sign) and N-terminal pro-brain natriuretic peptide in differentiating acute heart failure from chronic obstructive pulmonary disease and asthma as cause of acute dyspnea in prehospital emergency setting. Crit Care 2011;15:R114. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Shaikh K, Ahmad M. Diagnostic significance of NT-proBNP estimation in patients with acute dyspnea. J Coll Physicians Surg Pak 2011;21:584-8. [DOI] [PubMed] [Google Scholar]
- 46.Eckstein J, Potocki M, Murray K, Breidthardt T, Ziller R, Mosimann T, et al. Direct comparison of mid-regional pro-atrial natriuretic peptide with N-terminal pro B-type natriuretic peptide in the diagnosis of patients with atrial fibrillation and dyspnoea. Heart 2012;98:1518-22. [DOI] [PubMed] [Google Scholar]
- 47.National Institute for Cardiovascular Outcomes Research. National heart failure audit— April 2012-March 2013. www.ucl.ac.uk/nicor/audits/heartfailure/documents/annualreports/hfannual12-13.pdf.
- 48.Peacock W, Fonarow G, Emerman C, Mills R, Wynne J; ADHERE scientific advisory impact of early initiation of intravenous therapy for acute decompensated heart failure on outcomes in ADHERE. Cardiology 2007;107:44-51. [DOI] [PubMed] [Google Scholar]
- 49.Clerico A, Fontana M, Zyw L, Passino C, Emdin M. Comparison of the diagnostic accuracy of brain natriuretic peptide (BNP) and the N-terminal part of the propeptide of BNP immunoassays in chronic and acute heart failure: a systematic review. Clin Chem 2007;53:813-22. [DOI] [PubMed] [Google Scholar]
- 50.Worster A, Balion CM, Hill SA, Santaguida P, Ismaila A, McKelvie R, et al. Diagnostic accuracy of BNP and NT-proBNP in patients presenting to acute care settings with dyspnea: a systematic review. Clin Biochem 2008;41:250-9. [DOI] [PubMed] [Google Scholar]
- 51.Hu Z, Han Z, Huang Y, Sun Y, Li B, Deng A. Diagnostic power of the mid-regional pro-atrial natriuretic peptide for heart failure patients with dyspnea: a meta-analysis. Clin Biochem 2012;45:1634-9. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.