Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2016 Mar 1.
Published in final edited form as: Mol Imaging. 2015 Mar 1;14(0):1–9. doi: 10.2310/7290.2015.00005

Near-Infrared Fluorescent Digital Pathology for the Automation of Disease Diagnosis and Biomarker Assessment

Summer L Gibbs 1,, Elizabeth Genega 2, Jeffery Salemi 1, Vida Kianzad 1, Haley L Goodwill 1, Yang Xie 1, Rafiou Oketokoun 1, Parmeshwar Khurd 3, Ali Kamen 3, John V Frangioni 1,4,*,¥
PMCID: PMC4384048  NIHMSID: NIHMS675093  PMID: 25812603

Abstract

Hematoxylin and eosin (H&E) staining of tissue has been the mainstay of pathology for more than a century. However, the learning curve for H&E tissue interpretation is long while intra- and interobserver variability remains high. Computer-assisted image analysis of H&E sections holds promise for increased throughput and decreased variability, but has yet to demonstrate significant improvement in diagnostic accuracy. Addition of biomarkers to H&E staining can improve diagnostic accuracy, however co-registration of immunohistochemical staining with H&E is problematic as immunostaining is completed on slides that are at best 4 μm apart. Simultaneous H&E and immunostaining would alleviate co-registration problems; however current opaque pigments used for immunostaining obscure H&E. In this study, we demonstrate that diagnostic information provided by two or more independent wavelengths of near-infrared (NIR) fluorescence leave the H&E stain unchanged while enabling computer-assisted diagnosis and assessment of human disease. Using prostate cancer as a model system, we introduce NIR digital pathology and demonstrate its utility along the spectrum from prostate biopsy to whole mount analysis of H&E-stained tissue.

Keywords: Pathology, Hematoxylin and Eosin, Near-Infrared Fluorescence, Computer-Assisted Diagnosis, Prostate Cancer

INTRODUCTION

After hematoxylin [1] and eosin [2, 3] were introduced separately for tissue staining in 1865 and 1876, respectively, they were combined by Busch in 1878 [4] to produce the current gold standard for pathology, the hematoxylin and eosin (H&E) stain (reviewed in [5]). More than a century later, H&E remains the most widely used technique around the world, as it provides rich information content about tissue disease status.

Nevertheless, several fundamental difficulties plague pathology. First, the learning curve to interpret complex benign and disease tissue patterns provided by H&E requires significant training time, limiting the number of available pathologists to examine patient tissues. Prostate cancer is a particularly difficult clinical example, where diagnosis and disease grading by a highly trained genitourinary (GU) pathologist on the sparse tissue sampling of prostate biopsies yields an interobserver agreement of only 70% [6]. By comparison, when the same specimens are analyzed by generally trained pathologists, agreement falls to barely moderate [7]. The complexity of accurate prostate cancer diagnosis and grading from H&E stained prostate biopsies can be further demonstrated through the only 50% intraobserver repeatability by Dr. Gleason himself, who developed the World Health Organization accepted Gleason Grade for prostate cancer [8]. Second, the addition of immunohistochemical (IHC) staining to H&E can significantly improve diagnostic accuracy, but typically requires consecutive sections, which may be hundreds of microns away from the original H&E stained section within the tissue block. Thus, the features of interest for diagnostic and prognostic accuracy will at best have changed shape and size, and in the worst case, may not be present in both the H&E and immunohistochemical stained slides depending on the distance between sections. This is especially problematic for sparse tissue samples, such as routine diagnostic biopsy, where little tissue is collected from which to recognize disease patterns using conventional H&E staining. Additionally, when colorimetric methods are utilized for IHC detection, only a single antigen at a time can be analyzed requiring multiple sections for additional antigens. Co-staining with H&E and colorimetric IHC is also not desirable as the precipitated colored pigments obscure the original H&E stain. Clearly, a possible method for simultaneous immune- and H&E staining is through the use of immunofluorescence, which does not interfere with conventional H&E. However, it is not possible to use visible fluorophores in the presence of hematoxylin and eosin as both chromophores have strong absorbance in the visible region and eosin is highly fluorescent over much of the visible spectrum. To overcome this spectral overlap, immunofluorescence and H&E images are routinely correlated to one another through serial sectioning and imaging of complimentary regions on different sections of the same tissue specimen, but these methods suffer from similar alignment impediments as mentioned previously due to the fact that staining is completed on sections that are at best 5–10 μm apart [911]. Lastly, disease diagnosis through H&E staining, especially for prostate cancer, relies primarily on overall tissue pattern recognition, whereas modern biomarker studies, especially for cancer stem cells, stromal cells, and immune cells, require single cell analysis.

Two previously published strategies to facilitate improved co-registration of immune- and H&E staining include spectral unmixing of precipitated immunostains [12] and H&E de-staining followed by virtual microscopy [13]. While advantageous in their ability to add information to H&E stained tissue sections, both of these techniques permanently alter the H&E stained slide. Conventionally H&E stained slides are stored for future examination by the pathologist and thus spectral unmixing of precipitated immunostains and H&E de-staining techniques alter normal clinical workflow.

In this study, we report a new technology, termed near infrared (NIR) digital pathology, which exploits invisible NIR fluorescent light to add multiple layers of phenotypic and/or genotypic information content to standard H&E-stained tissue sections on the same tissue section. Immunofluorescence staining using NIR fluorophores can alleviate the spectral overlap of H&E with visible fluorophores while maintaining the integrity of the original H&E stained slide enabling perfect coregistration of immunostaining and H&E without altering that ability for archiving and future examination.

MATERIALS & METHODS

Spectral Characterization

Absorbance and fluorescence spectra of hematoxylin (Fisherbrand Gill Method, Stain 3), eosin (Eosin Y, Fisher Scientific), rabbit anti-donkey conjugated Alexa Fluor 680 (Life Technologies, Grand Island, NY), and mouse anti-goat (Jackson Immunoresearch, West Grove, PA) conjugated ZW800-1 [14, 15] were collected using a Cary 50 Bio UV-Visible spectrophotometer and Cary Eclipse fluorescence spectrometer, respectively (Varian/Agilent, Mattapoisett, MA). Excitation wavelengths blue-shifted from the absorption maxima were chosen for each chromophore to enable collection of full fluorescence spectra. Spectra from hematoxylin were collected in deionized water. All absorbance and fluorescence spectra were normalized to accurately portray spectral shape and wavelength range among the chromophores.

Labeling of Antibody with ZW800-1

Mouse anti-goat secondary antibody was conjugated to ZW800-1 N-Hydroxysuccinimidal (NHS) ester (10 mM stock solution in anhydrous dimethyl sulfoxide) at a conjugation ratio of 2–3 fluorophore molecules per antibody using the following protocol. The antibody was buffer exchanged with PBS using a 10,000 Dalton molecular weight cut off (10K MWCO) spin column (Vivaspin, Fisher Scientific) prior to resuspension in PBS. The pH of the antibody solution was raised to 8.0 using sodium phosphate dibasic (35 mM, Fisher Scientific). Twenty molar equivalents of ZW800-1 NHS ester were added to the antibody solution dropwise. The reaction was agitated gently at room temperature (RT) for 3 h.

The conjugated antibody was purified from the free fluorophore using an Akta Prime (GE Healthcare Life Sciences, Pittsburg, PA) gel filtration chromatography system and desalting columns (Bio-Scale Mini Bio-gel, Bio-Rad, Hercules, CA). The antibody solution was loaded onto the column where PBS (0.1X) was run at 2 mL/min. After about 6 min, the conjugated antibody flowed from the column, which was collected in 1 mL fractions 5–7 min following column loading. The conjugated antibody containing was further purified and concentrated using a 10K MWCO spin column. The conjugation ratio and protein concentration for the conjugated antibody were calculated using absorbance measurements collected with the Cary 50 Bio UV-Visible spectrometer, where the extinction coefficient (ε) was 210,000 M−1cm−1 at 280 nm for the antibody and 249,000 M−1cm−1 at 770 nm for ZW800-1 [15].

Antigen Retrieval for Prostate Tissue Specimens

Discarded anonymized human prostate tissue specimens were acquired under an approved IRB protocol from the pathology department at Beth Israel Deaconess Medical Center as formalin fixed paraffin embedded tissue blocks. The tissues were sectioned at 4 μm thickness and dried thoroughly. The paraffin was removed from the slides using an Autostainer XL (Leica Microsystems, Buffalo Grove, IL) where the slides were incubated as follows: xylenes (5 min), xylenes (5 min), 100% ethanol (1 min), 100% ethanol (1 min), 95% ethanol (1 min), water (3 min). To unmask antigens for antibody staining, antigen retrieval was completed in the following buffer; 10 mM Tris base (Fisher Scientific), 1 mM EDTA (Fisher Scientific), and 0.05% Tween 20 (Sigma Aldrich) in PBS, pH 8. The slides were boiled in the Tris-EDTA buffer for 20 min, after which the buffer and slides were removed from the pressure cooker and allowed to cool at RT for 20 min.

Simultaneous Same-Slide NIR Fluorescence and H&E Staining

The slides were washed three times with PBS-T (PBS with 0.1% Tween 20). All slides were blocked with 5% normal goat serum (Jackson Immunoresearch catalog #005-000-001) in PBS for 1 h at RT. Monoclonal mouse anti-human high molecular weight cytokeratin primary antibody (Dako clone #34βE12, Carpinteria, CA) was diluted from the stock solution at 1:50 and mixed with monoclonal rabbit anti-human alpha-methylacyl-CoA racemase (AMACR, Dako clone #13H4) diluted from the stock solution at 1:100. The primary antibody solution was incubated on the tissue in a humidified chamber overnight at 4°C. Following The primary antibody removal, the slides were washed three times with PBS-T. Donkey anti-mouse conjugated to Alexa Fluor 680 (Life Technologies catalog #A10038) was diluted 1:50 and mixed with unlabeled goat anti-mouse (Jackson Immunoresearch catalog #115-005-146) diluted 1:50 and incubated with the tissue for 1 h at RT protected from light. The secondary antibody solution was removed and the slides were washed three times with PBS-T for 5 min per wash. Mouse anti-goat conjugated to ZW800-1 was diluted to 0.25 μM protein concentration and incubated with the tissue for 1 h at RT protected from light. After washing of the tertiary antibodies, the tissue was fixed with 2% paraformaldehyde (PFA) in PBS for 15 min at RT. The fixative was removed and the tissue was washed once with PBS for 5 min.

Following antibody staining and fixation, the Autostainer XL was used to perform standard H&E staining of the slides. The following protocol was used for standard H&E staining: hematoxylin (3 min), water (2 min), ammonia water (10 sec), water (2 min), eosin (2 min), 95% ethanol (1 min), 100% ethanol (1 min), 100% ethanol (1 min), xylenes (2 min), xylenes (2 min). The slides were removed from the final xylene wash, mounted with Permount mounting medium (Fisher Scientific catalog #SP15-500) and coverslipped.

Simultaneous Brightfield and NIR Fluorescence Microscopy

Simultaneous brightfield and NIR fluorescence microscopy images were collected on a modified Nikon 55i fluorescence microscope with a programmable, motorized, encoded stage (Prior Scientific, Rockland, Massachusetts). The stage was equipped with interchangeable adaptors to accommodate either a 1″ × 3″ (prostate needle biopsies) or 2″ × 3″ (prostate whole mount) slide. The microscope was equipped with a custom beam splitter on the camera port to accommodate a 12-bit color camera (Prosilica, Allied Vision Technologies, Burnaby, British Columbia, Canada) for brightfield imaging and an Orca-ER 12-bit camera for fluorescence imaging (Hamamatsu, Bridgewater, NJ). All filters were from Chroma Technologies (Brattleboro, VT). For imaging of Alexa Fluor 680, the xenon lamp was passed through a 650 ± 22.5 nm BP excitation filter, a 680 nm LP dichroic, and 710 ± 25 nm BP emission filter. For imaging of ZW800-1 the xenon lamp was passed through a 750 ± 25 nm BP excitation filter, 790 nm LP dichroic, and 824 ± 23.5 nm BP emission filter. The white light used for brightfield illumination was depleted of all NIR wavelengths using a 650 nm SP filter.

Using custom software, a calibration image was collected for flat field correction for the color, 700 nm, and 800 nm channels. The exposure times for the 700 nm and 800 nm channels were set based on the average fluorescence signal intensity seen in the sample dataset to prevent image saturation. The slides were scanned with 10% overlap first for color, followed by 800 nm fluorescence emission, then for 700 nm fluorescence emission. A color dataset using a 4X objective from the entire slide was collected and used for specimen detection.

All 2″ × 3″ slides were scanned at a maximum magnification of 10X. The z-focus for the entire slide was determined using two focused points at one end of the slide and a third focused point at the opposite end of the slide to calculate the focal plane. The focal information was used to collect the color images directly and used with an empirically determined offset to collect the 700 nm and 800 nm fluorescence images. The 1″ × 3″ slides containing prostate needle biopsy specimens were scanned at a magnification of 40X to enable sufficient magnification to identify nucleoli for diagnostic purposes. Due to inhomogeneities in the glass height of the slides, a custom autofocusing algorithm was used to determine z-focus, which was autofocused using seven z-steps every five images. The focused z-coordinates were saved and used with the empirically derived offset factor to acquire 700 nm and 800 nm fluorescence images. Following completion of scanning, all data was flat field corrected using the acquired calibration images for color, 700 nm, and 800 nm fluorescence. Using custom software, the corrected data was registered and stitched into a single map [16], which was digitally down sampled from the maximum resolution to 1X resolution in 8 steps that were each saved as individual images.

NIR fluorescence images were acquired and saved as raw 12-bit data (pixel intensity values ranging from 0 to 4095). Preliminary scanning permitted adjustment of camera exposure time to ensure that pixel saturation did not occur. Brightness, contrast, and gamma for the entire stitched image of a particular NIR wavelength could then be adjusted to maximize dynamic range of the displayed data.

RESULTS

Spectral Characteristics of NIR Immunofluorescence, Hematoxylin, and Eosin

Due to the absorbance (Figure 1a) and emission (Figure 1b) of hematoxylin and eosin, visible fluorescence cannot be used with H&E staining. Hematoxylin has broad absorption between 400–700 nm with virtually no fluorescence emission. Eosin has much narrower absorption (450–550 nm), but exhibits strong fluorescence emission ranging from 500–700 nm. NIR fluorophores, which emit between 700–900 nm and typically have a Stokes shift of ≥ 15 nm, are ideal for adding information content to H&E slides. As shown in Figure 1, emission wavelengths for the two most common classes of NIR fluorophores, i.e., those with peak emission ≈ 700 nm and ≈ 800 nm, are non-overlapping with H&E.

Figure 1. Spectral Characterization of H&E and NIR Fluorophores.

Figure 1

a. Absorption spectra at matched peak absorbance for hematoxylin, eosin, Alexa Fluor 680 conjugated to donkey anti-mouse antibody (Dk anti-Ms AF680), and ZW800-1 conjugated to mouse anti-goat antibody (Ms anti-Gt ZW800-1).

b. The corresponding normalized fluorescence emission spectra of compounds from A (note, hematoxylin was not fluorescent).

Simultaneous Two-Wavelength NIR Fluorescence and H&E for Disease Detection

Unlike many diseases, where the presence or absence of single cells can provide diagnostic and prognostic value, prostate cancer requires high-level analysis of glandular patterns. Analysis is further confounded by the fact that a 4 μm section of a 3D object results in many distorted gland geometries that are not interpretable. NIR fluorescence, however, can render virtually any tissue section informative. The biomarker α-methylacyl-CoA racemase (AMACR) stains the spectrum of abnormal prostate tissue from premalignant prostatic intraepithelial neoplasia (PIN) through Gleason grade 5 prostate adenocarcinoma [1720] while high molecular weight cytokeratin (CK903) is a basal cell marker that stains normal glands and PIN [21, 22]. The combination of the two biomarkers can aid in tissue classification when added to H&E staining where benign (AMACR −, CK903 +), PIN (AMACR +, CK903 +), and malignant (AMACR +, CK903−) glands demonstrate distinct immunostaining patterns [18, 20, 22]. As shown in Figure 2, NIR fluorescence permits independent assessment of biomarkers in the context of the same tissue specimen, without alteration of the conventional H&E stain. It also permits overlay of the two NIR fluorescence channels with the H&E, thus providing single cell level coregistration of biomarkers and histology. Of note, 800 nm fluorophores were purposely utilized for nuclear antigens because of hematoxylin’s strong absorption into the red wavelengths. Additionally, tertiary antibody staining was used to amplify the signal from weak antigens.

Figure 2. Disease Detection using Simultaneous NIR Fluorescence and H&E.

Figure 2

Prostate specimens were stained with an AMACR-specific primary antibody and visualized using Dk-Ms AF680 (700 nm NIR fluorescence channel), as well as a CK903-specific primary antibody and visualized using Ms-Gt ZW800-1 (800 nm NIR fluorescence channel). In the H&E/NIR Merge image, the 700 nm channel is pseudo-colored in yellow and the 800 nm channel is pseudo-colored in in lime green. Representative images of benign, malignant, and mixed benign and malignant prostate glands are shown. Scale bars = 200 μm.

Digitized Biomarker Maps of Large Specimens using NIR Digital Pathology

As our understanding of diseases like prostate cancer evolves, it has become clear that tumor heterogeneity can be extreme [23, 24]. Whole mounts, where the entire resected prostate gland is sectioned and stained on 2″ × 3″ slides, provide a map of disease heterogeneity, which can be difficult to fully catalog and analyze manually. As shown in Figure 3a, NIR digital pathology permits biomarker detection and quantitation over an entire whole mount section while preserving the H&E staining that is required by pathologists for disease confirmation. Areas suspicious for malignancy can be rapidly detected using the NIR fluorescence channels and confirmed at higher resolution through both immunofluorescence and H&E (Figure 3a).

Figure 3. Biomarker Analysis of Whole Mount Radical Prostatectomy Specimens and Sparse Prostate Needle Biopsy Specimens.

Figure 3

Figure 3

a. 2″ × 3″ whole mount sections of prostatectomies were stained as described for Figure 2 and scanned at 10X magnification with 10% overlap followed by stitching of the 2850 individual images into a single map of the prostatectomy section for the H&E, 700 nm NIR fluorescence and 800 nm NIR fluorescence channels. The images were then digitally down sampled to visualize the entire specimen. Scale bar = 5 mm. Insets on bottom two rows correspond to malignant (solid box and arrow) and benign (dashed box and arrow) areas. Inset scale bars = 200 μm.

b. A representative prostate needle core biopsy was stained and displayed as described for Figure 2 except scanning was performed at 40X magnification. The images were digitally downsampled to visualize the entire specimen. Scale bar = 500 μm.

Semi-Automated and Automated Analysis of Sparse Biopsy Samples

The most profound problem in prostate cancer care is making significant clinical decisions based on the sparse tissue obtained from core needle biopsy. Even if 20 or more needle cores are analyzed from a single patient, this represents only a small percentage of the prostate volume, and heterogeneity can be substantial (see Figure 3a, for example). Because prostate cancer requires high-level analysis of glandular patterns and intra- and interobserver repeatability can be relatively low, accurate diagnosis and grading of biopsies is particularly challenging due to the sparse tissue sampling. As shown in Figure 3b, NIR digital pathology permits prostate needle biopsies to be analyzed at near single cell resolution, with areas suspicious for PIN and adenocarcinoma initially identified without pathologist intervention. Moreover, using simple image analysis, the fraction of the biopsy occupied by malignancy or premalignancy can be quantified with high precision, as compared to the conventional clinical method of qualitatively assigning fractional involvement.

The potential of NIR fluorescence-derived biomarker information is highlighted in the representative example shown in Figure 4, where a trained genitourinary pathologist was asked to identify prostate cancer on a needle biopsy specimen using only the digital H&E image at two different magnifications. While the large areas of Gleason score 6 (3+3) adenocarcinoma were readily identified, there were also areas representing partial glands that were not definitively identified by H&E alone. However, by biomarker assessment these glandular structures demonstrated AMACR staining and were further examined for malignancy. Because many needle biopsies have indistinguishable glands present [25], independent biomarker assessment could significantly improve pathological diagnosis as well as intra- and interobserver repeatability.

Figure 4. Annotated Core Needle Prostate Biopsy.

Figure 4

a. A representative core needle prostate biopsy stained and displayed as described for Figure 3A was annotated by an experienced genitourinary (GU) pathologist. Malignant regions are circled in black and were found to contain prostatic adenocarcinoma with a Gleason score of 6 (primary Gleason grade 3 and secondary Gleason grade 3; 3+3). Scale bar = 200 μm.

b. Zoomed images of the middle portion of the core needle prostate biopsy demonstrate that NIR fluorescence identifies five otherwise indeterminant glandular structures that are positive for malignancy, but were not annotated by the GU pathologist. Arrows point to these three AMACR-positive glands in the H&E image. Scale bar = 50 μm.

DISCUSSION

As our understanding of cancer evolves, the literature strongly suggests enhanced information content will improve diagnosis, treatment selection and patient prognosis. With more than a century of diagnostic and prognostic experience using H&E tissue staining, a technology that enhances its information content would significantly improve patient care. In addition, the advances in genomics and proteomics as well as the novel phenotypic and genotypic biomarkers for diseases are rapidly developing, however the technology to validate these against gold standard H&E hasn’t been previously available. In the work presented herein we demonstrate a facilitating fluorescence-biomarker assessment technology termed NIR digital pathology for single cell co-registration with H&E staining.

The enabling technology behind our NIR digital pathology technique is the spectral separation between the absorption and emission spectra of NIR fluorophores and the H&E chromophores. In the current work, we have demonstrated proof of principles studies on prostate whole mounts and biopsy specimens using two-color antibody based staining. High molecular weight cytokeratin (CK903) was used as a biomarker to delineate benign glands while AMACR, an antigen present in the spectrum of premalignant and malignant prostate glands, was used to mark suspicious glandular tissues. Whole mount prostatectomy specimens were imaged for CK903, AMACR and H&E through NIR digital pathology demonstrating the significant disease heterogeneity present in the representative example of prostate adenocarcinoma. Additionally, prostate biopsy specimens were also imaged using NIR digital pathology, where disease diagnosis generally shows increased variability due to the sparse tissue sampling. Although proof of principle was established in this study using antibodies, NIR fluorophores are routinely conjugated to nucleic acids, small molecules, and other protein ligands, permitting virtually any combination of phenotypic and/or genotypic markers to be analyzed in future work. In addition, NIR digital pathology should perform similarly well with pathology stains other than H&E. The only two requirements are that they don’t have spectral overlap with NIR fluorophores and that processing conditions are compatible with polymethine indocyanines, e.g., avoidance of highly basic conditions.

NIR digital pathology provides high versatility in quantifying and interpreting NIR fluorescence signals. Because scanning is typically performed with a 40X objective (≈ 1–2 μm resolution), individual cells can be readily identified from the H&E image based on simple segmentation for chromatin. Once identified, NIR fluorescence signals can be assigned to individual cells or collections of cells (e.g., glands). Because of the high dynamic range (12-bit) of the NIR data sets, the distinction between NIR signals deemed positive or negative is straightforward, and can even be done on the fly by adjusting segmentation windows and thresholds. Using these methods, the presence or absence of biomarkers can be quantified at the single cell level, glandular level, or section level as needed.

As NIR digital pathology is further developed and validated we envision this technology will be useful in a number of clinical scenarios. First, it could be used to automatically pre-screen biopsy specimens for the presence of disease so that pathologists would spend their time on informative areas of the slide, spending less time “finding” suspicious areas with the potential for decreased incidence of missing small lesions. The combination of computer-aided diagnosis via H&E staining as well as the addition of biomarker information through NIR immunofluorescence could enable pre-screening for disease. Second, NIR digital pathology can be used to perform immunostaining on the same slide. This would eliminate the current laborious technique of consecutive sectioning and the associated co-registration problems. Third, for validation of new biomarkers, where comparison to gold standard H&E is essential, NIR digital pathology permits two or more biomarkers to be simultaneously identified on a single slide. And, finally, NIR digital pathology could enable effective telemedicine. With a worldwide shortage of specialty pathologists, especially in genitourinary pathology, digitization and pre-screening by NIR digital pathology would permit transmission of relatively small amounts of digital data as opposed to terabytes of benign data present on each slide. It should be stated clearly that the goal of this technology is not to replace pathologists, but rather to increase diagnostic efficiency and provide tools for validation of next generation biomarkers with conventional H&E staining with which the medical community has more than 130 years of experience.

The work presented herein serves to demonstrate the basics of the technology and its potential utility in prostate cancer diagnosis. Future work will be focused on validation of the NIR digital pathology for prostate cancer diagnosis as well as digital image analysis and computer-aided tissue pattern recognition. As is evidenced from the representative examples of prostate cancer, segmentation could be utilized to identify areas of benign, pre-malignant, and malignant tissues to quantify disease. However, there is undoubtedly additional information content in the pattern of NIR fluorescence that is yet to be explored, which for example, could be used to assign a Gleason score to prostate cancer specimens, as has been tried for automated assignment using H&E [2628]. Through the combined use of H&E pattern recognition and NIR digital pathology it could be possible to standardize the assessment of cancer versus benign tissue areas, something that is now completed in coarse, qualitative terms, but which is one of many factors used by clinicians to make therapeutic decisions.

Acknowledgments

We would like to thank Victoria Madigan, Kathleen Cunningham, Nicholas Durr, David Claypool, Victor Laronga, and Jennifer Goodhart for experimental assistance, David J. Burrington, Jr. for editing, and Eugenia Trabucchi, Linda Keys, and Lorissa Moffitt for administrative assistance. This study was funded by National Institute of Health (NIH) grants R01-CA-134493 and R01-CA-115296.

Footnotes

Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIH.

References

  • 1.Böhmer F. Zur pathologischen Anatomie der Meningitis cerebromedullaris epidemica. Ärztl Intelligenzbl München. 1865;12:539–550. [Google Scholar]
  • 2.Dreschfeld J. Über eine neue Tinctionsflüssigkeit für histologische Zwecke. Centralblatt für die medicinischen Wissenschaften. 1876;14:705–706. [Google Scholar]
  • 3.Fischer E. Eosin als Tinctionsmittel für mikroskopische Präparate. Arch Mikrosk Anat. 1876;12:349–352. [Google Scholar]
  • 4.Busch H. Über die Doppelfärbung des Ossificationsrandes mit Eosin and Haematoxylin. Arch Physiol (Archiv für Physiologie) 1878:594–595. [Google Scholar]
  • 5.King DF, King LA. A brief historical note on staining by hematoxylin and eosin. The American Journal of dermatopathology. 1986;8(2):168. doi: 10.1097/00000372-198604000-00013. [DOI] [PubMed] [Google Scholar]
  • 6.Allsbrook WC, Jr, et al. Interobserver reproducibility of Gleason grading of prostatic carcinoma: urologic pathologists. Human pathology. 2001;32(1):74–80. doi: 10.1053/hupa.2001.21134. [DOI] [PubMed] [Google Scholar]
  • 7.Allsbrook WC, Jr, et al. Interobserver reproducibility of Gleason grading of prostatic carcinoma: general pathologist. Human pathology. 2001;32(1):81–8. doi: 10.1053/hupa.2001.21135. [DOI] [PubMed] [Google Scholar]
  • 8.Gleason DF. Histologic grading of prostate cancer: a perspective. Human pathology. 1992;23(3):273–9. doi: 10.1016/0046-8177(92)90108-f. [DOI] [PubMed] [Google Scholar]
  • 9.Calfon MA, et al. Intravascular near-infrared fluorescence molecular imaging of atherosclerosis: toward coronary arterial visualization of biologically high-risk plaques. J Biomed Opt. 2010;15(1):011107. doi: 10.1117/1.3280282. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Jaffer FA, et al. Real-time catheter molecular sensing of inflammation in proteolytically active atherosclerosis. Circulation. 2008;118(18):1802–9. doi: 10.1161/CIRCULATIONAHA.108.785881. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Liu Y, et al. Complementary fluorescence-polarization microscopy using division-of-focal-plane polarization imaging sensor. J Biomed Opt. 2012;17(11):116001. doi: 10.1117/1.JBO.17.11.116001. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Levenson RM. Spectral imaging perspective on cytomics. Cytometry. Part A: the journal of the International Society for Analytical Cytology. 2006;69(7):592–600. doi: 10.1002/cyto.a.20292. [DOI] [PubMed] [Google Scholar]
  • 13.Helin HO, et al. Virtual microscopy in prostate histopathology: simultaneous viewing of biopsies stained sequentially with hematoxylin and eosin, and alpha-methylacyl-coenzyme A racemase/p63 immunohistochemistry. The Journal of urology. 2006;175(2):495–9. doi: 10.1016/S0022-5347(05)00164-3. [DOI] [PubMed] [Google Scholar]
  • 14.Choi HS, et al. Targeted zwitterionic near-infrared fluorophores for improved optical imaging. Nature biotechnology. 2013;31(2):148–53. doi: 10.1038/nbt.2468. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Choi HS, et al. Synthesis and in vivo fate of zwitterionic near-infrared fluorophores. Angewandte Chemie. 2011;50(28):6258–63. doi: 10.1002/anie.201102459. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Khurd P, et al. Global error minimization in image mosaicing using graph connectivity and its applications in microscopy. J Pathol Inform. 2011;2:S8. doi: 10.4103/2153-3539.92039. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Brimo F, Epstein JI. Immunohistochemical pitfalls in prostate pathology. Human pathology. 2012;43(3):313–24. doi: 10.1016/j.humpath.2011.11.005. [DOI] [PubMed] [Google Scholar]
  • 18.Jiang Z, et al. Using an AMACR (P504S)/34betaE12/p63 cocktail for the detection of small focal prostate carcinoma in needle biopsy specimens. American journal of clinical pathology. 2005;123(2):231–6. doi: 10.1309/1g1nk9dbgfnb792l. [DOI] [PubMed] [Google Scholar]
  • 19.Jiang Z, et al. P504S: a new molecular marker for the detection of prostate carcinoma. The American journal of surgical pathology. 2001;25(11):1397–404. doi: 10.1097/00000478-200111000-00007. [DOI] [PubMed] [Google Scholar]
  • 20.Ouyang B, et al. alpha-Methylacyl-CoA racemase spliced variants and their expression in normal and malignant prostate tissues. Urology. 2011;77(1):249 e1–7. doi: 10.1016/j.urology.2010.08.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Humphrey PA. Diagnosis of adenocarcinoma in prostate needle biopsy tissue. Journal of clinical pathology. 2007;60(1):35–42. doi: 10.1136/jcp.2005.036442. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Paner, Luthringer GPDJ, Amin MB. Best practice in diagnostic immunohistochemistry: prostate carcinoma and its mimics in needle core biopsies. Archives of pathology & laboratory medicine. 2008;132(9):1388–96. doi: 10.5858/2008-132-1388-BPIDIP. [DOI] [PubMed] [Google Scholar]
  • 23.Yoshimoto M, et al. PTEN losses exhibit heterogeneity in multifocal prostatic adenocarcinoma and are associated with higher Gleason grade. Mod Pathol. 2013;26(3):435–47. doi: 10.1038/modpathol.2012.162. [DOI] [PubMed] [Google Scholar]
  • 24.Greaves M, Maley CC. Clonal evolution in cancer. Nature. 2012;481(7381):306–13. doi: 10.1038/nature10762. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Boran C, et al. Reliability of the 34betaE12, keratin 5/6, p63, bcl-2, and AMACR in the diagnosis of prostate carcinoma. Urologic oncology. 2011;29(6):614–23. doi: 10.1016/j.urolonc.2009.11.013. [DOI] [PubMed] [Google Scholar]
  • 26.Khurd P, et al. Computer-Aided Gleason Grading of Prostate Cancer Histopathological Images Using Texton Forests. Proc IEEE Int Symp Biomed Imaging; 14–17 April 2010; 2010. pp. 636–639. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Madabhushi A, et al. Computer-aided prognosis: predicting patient and disease outcome via quantitative fusion of multi-scale, multi-modal data. Comput Med Imaging Graph. 2011;35(7–8):506–14. doi: 10.1016/j.compmedimag.2011.01.008. [DOI] [PubMed] [Google Scholar]
  • 28.Doyle S, et al. A boosted Bayesian multiresolution classifier for prostate cancer detection from digitized needle biopsies. IEEE Trans Biomed Eng. 2012;59(5):1205–18. doi: 10.1109/TBME.2010.2053540. [DOI] [PubMed] [Google Scholar]

RESOURCES