Abstract
Background
Lung protective ventilation strategies utilizing lower tidal volumes per predicted body weight (PBW) and positive end-expiratory pressure (PEEP) have been suggested to be beneficial in a variety of surgical populations. Recent clinical studies have used control groups ventilated with high tidal volumes without PEEP based on the assumption that this reflects current clinical practice. We hypothesized that ventilation strategies have changed over time, that most anesthetics in U.S. academic medical centers are currently performed with lower tidal volumes, and that most receive PEEP.
Methods
Intraoperative data were pooled for adults undergoing general anesthesia with tracheal intubation. Median tidal volumes per kilogram of PBW were categorized as > 10, 8–10 and < 8 mL per kg of PBW. The percentages of cases in 2013 that were performed with median tidal volumes < 8 mL per kg of PBW and PEEP were determined. As a secondary analysis, a proportional odds model using institution, year, height, weight and gender determined the relative associations of these factors using categorical and interquartile odds ratios.
Results
295,540 cases were analyzed from 5 institutions over a period of 10 years. In 2013, 59.3% of cases used median tidal volumes < 8 mL per kg of PBW, 83.3% used PEEP, and 51.0% used both. Of those cases with PEEP, 60.9% used a median pressure of ≥ 5 cmH2O. Predictors of lower categories of tidal volumes included height (odds ratio (OR) 10.83, 95% confidence interval [10.50, 11.16]), institution (lowest OR 0.98 [0.96, 1.00], highest OR 9.63 [9.41, 9.86]), year (lowest OR 1.32 [1.21, 1.44], highest OR 6.31 [5.84, 6.82]), male gender (OR 1.10 [1.07, 1.12]), and weight (OR 0.30 [0.29, 0.31]).
Conclusion
Most general anesthetics with tracheal intubation at the institutions surveyed are currently performed with a median tidal volume < 8 mL per kg of PBW, most are managed with PEEP of ≥ 5 cmH2O and approximately half utilize both. Given the diversity of the institutions included, this is likely reflective of practice in U.S. academic medical centers. The utilization of higher tidal volumes without PEEP in control groups for clinical research studies should be reconsidered.
Electronic supplementary material
The online version of this article (doi:10.1186/s12871-015-0010-3) contains supplementary material, which is available to authorized users.
Keywords: Intraoperative ventilation, Lung protective ventilation, Practice patterns
Background
The demonstration of a significant mortality benefit utilizing lung protective ventilation strategies in patients with acute respiratory distress syndrome (ARDS) suggests the possibility that using this approach may be beneficial during intraoperative ventilation in patients at risk for postoperative pulmonary complications [1]. Benefits from using lung protective ventilation strategies with tidal volumes below 8 mL per kilogram of predicted body weight (PBW) and positive end-expiratory pressure (PEEP) have been suggested in a variety of surgical populations [2-4], and could stem from reducing the risk of developing lung injury and other postoperative pulmonary complications. Higher tidal volumes that were historically used to prevent atelectasis (e.g., greater than 10 mL per kg of PBW) are associated with lung inflammation in animal models [5-7], as well as worsened clinical outcomes in humans [8], which may be secondary to lung overinflation in at risk areas leading to systemic and pulmonary inflammatory responses [9,10]. While it is now generally accepted that lung protective ventilation is indicated for patients with established lung injury, it remains unclear what the most appropriate ventilation strategy is for patients with non-injured lungs at increased risk for postoperative pulmonary complications. Examples of such patients at risk include those with sepsis, cirrhosis, and those undergoing high-risk aortic vascular, high-risk cardiac surgery and emergency surgery [11]. Despite controversy [12] over whether available data are sufficient to support the use of lung protective ventilation in all surgical patients, there is evidence that clinical practice has already begun to adopt some elements of these approaches [13,14]. Importantly, these changes have potential implications for contemporary research regarding perioperative ventilator management in patients at increased risk for postoperative pulmonary complications.
Understanding the appropriate intraoperative ventilation strategy for patients requires experimental evidence that convincingly demonstrates improved outcomes in the relevant patient population compared to current recommendations. While there have been recent experimental studies with significant effects on meaningful outcomes, the control groups in those studies were ventilated with tidal volumes of 10–12 mL per kg of PBW without PEEP based on the assumption that such a strategy is routine in current clinical practice [3,15]. Indeed, a basic assumption of a major recent trial was that “use of high tidal volumes and no PEEP is still commonplace” [15]. Defining current clinical practices is a fundamental step in establishing appropriate control groups so that clinical research studies can be conducted in a clinically relevant context.
The purpose of this study is to elucidate temporal trends, and to determine current practice patterns in intraoperative ventilation to guide the design of future clinical research studies. We hypothesized that most adult, non-cardiothoracic and non-neurosurgical anesthetics from a sample at 5 academic medical centers in the U.S. are currently performed with median tidal volumes below 8 mL per kg of PBW. We further hypothesize that most of these cases received PEEP.
Methods
Patient population
This study received an exemption from institutional review board (IRB) approval by the Vanderbilt University Human Research Protection Program-Institutional Review Board, an exemption from IRB approval from the Colorado Multiple Institutional Review Board, IRB approval from Mayo Clinic’s Office for Human Research Protection-Institutional Review Board, IRB approval from Partners Human Research Committee, and a determination of non-human subject research from the Division of Human Subjects Protection at Thomas Jefferson University. At each institution, the requirement for written, informed consent from patients was waived. Patients aged 18 and older who received general anesthesia with tracheal intubation between 2005 and 2013 were screened. Each institution defined its own start date based on the availability of electronically captured ventilator data. Patients who underwent procedures with potential confounding ventilation considerations were not included, specifically those undergoing cardiac, thoracic, neurosurgical, laparoscopic and one lung ventilation procedures, as well as organ harvest. Cases without adequate data for analysis were excluded as described below.
Data collection
Data were retrieved electronically from each institution’s anesthesia information management system (AIMS). At each site, AIMS data were extracted and de-identified. This was achieved by creating a de-identified case number, listing patients 90 years or older with an age of 90, removing date information with the exception of case year and calculating all physiologic and ventilator data timestamps relative to entry into the OR. Files were encrypted and transmitted using a secure website to Vanderbilt University, the coordinating institution, and were then loaded into a SQL Server database (Microsoft, Redmond, WA). The relevant data elements transmitted for each case were institution number, de-identified case number, year, American Society of Anesthesiologists (ASA) Physical Status, emergency vs. elective case status as defined by the presence of an ASA E flag, height in centimeters, weight in kilograms, age, gender, primary surgical service, surgical Current Procedural Terminology (CPT) code, anesthesia CPT code, total case duration (i.e., entry to exit from room), times of surgical incision and end of surgery, use of lung isolation, use of a laparoscopic approach, and whether the case was a cardiac, thoracic or neurosurgical case. For each case, the following ventilation data were retrieved: peak inspiratory pressure, PEEP, exhaled tidal volume, mean airway pressure, respiratory rate (RR), ventilation mode, fraction of inspired oxygen (FiO2), oxygen saturation via pulse oximetry (SpO2) and end-tidal carbon dioxide (EtCO2). Not all data elements used to define the surgical procedure were available at all institutions; thus multiple data elements were included to define case exclusions.
Data processing
The minimum, maximum, average and median of each data element at each institution between incision and end of surgery were examined to rule out systematic problems with the data extraction process. The exclusion criteria were sequentially applied to the screened cases (Figure 1). Patients missing heights, or with a height less than 152 cm or greater than 203 cm were excluded to be consistent with prior work [13], as were those with unknown or missing genders, weight below 40 kg or above 300 kg, oxygen saturation (SpO2) above 100% or with median values below 50%, and median tidal volumes below 3 mL per kg of PBW. PBW was determined using gender and height per ARDSnet definition [16]. Specifically, for males, PBW was calculated as [(height (cm) -154) × 0.9] + 50. For females, PBW was calculated as [(height (cm) -154) × 0.9] + 45.5.
We excluded cases where there may have been overriding patient or procedural factors that may have altered routine ventilation strategies, such as one lung ventilation, cardiopulmonary bypass, elevated intracranial pressure, and use of laparoscopy. Specifically, we excluded thoracic, cardiac, and neurosurgical cases, and cases with use of laparoscopy. Thoracic cases were defined based on the primary surgical service field, a positive value for the one lung ventilation flag, or an anesthesia CPT code indicating one lung ventilation. Cardiac cases were defined based on the primary surgical service field. Neurosurgical cases were defined based on the primary surgical service field or an anesthesia CPT code indicating an intracranial procedure. Non-intracranial procedures performed by neurosurgical services were excluded. Laparoscopic cases were defined as those with a positive value for the laparoscopic flag or the presence of ‘laparoscopic’ at any point in the text description of the surgical procedure.
Surgical duration was calculated as the difference in minutes between the incision and end of surgery times. Where missing, the surgical end time was imputed as 30 minutes prior to leaving the OR. Cases with missing incision time were excluded. Brief cases (i.e., surgical duration less than 30 minutes) were excluded to focus on the maintenance phase of anesthesia where the ventilation strategy is less likely to be impacted by preparation for extubation.
Statistical analysis
Demographic variables were summarized with means and standard deviations for continuous variables and with percentages for categorical variables. Ventilator parameters were defined within each case at the 25th, 50th and 75th percentiles, restricting the analysis to the interval between incision and end of surgery. All tidal volumes refer to exhaled tidal volumes. Cases were divided into a three category ordered outcome with median tidal volumes > 10 mL per kg of PBW (traditional), 8–10 mL per kg of PBW (intermediate) and < 8 mL per kg of PBW (physiologic tidal volume during quiet breathing at rest), breakpoints selected to differentiate ventilation consistent with ARDSnet recommendations of 6–8 mL per kg of PBW [16] from traditional strategies of > 10 mL per kg used to prevent atelectasis [15], while also including an intermediate category. The primary analysis was to determine if most anesthetics performed in 2013 used a median tidal volume of < 8 mL per kg of PBW and if most of those anesthetics used PEEP. As a secondary analysis, a proportional odds model was used to examine factors associated with a higher tidal volume category (traditional vs. intermediate, intermediate vs. physiologic) using predictors previously identified [17] and adding institution and year. The pre-specified covariates were year, institution, gender, height and actual body weight. Body weight was modeled rather than body mass index, as height was already included in the model. As the number of included cases was large, height and body weight were modeled using restricted cubic splines with 4 knots (placed at quartiles 0.05, 0.35, 0.65, 0.95) in order to identify non-linear effects. The remaining parameters were modeled as categorical variables. The odds of receiving a lower category of tidal volume (traditional vs. intermediate, intermediate vs. physiologic) were computed for height and weight as interquartile odds ratios, which represent comparisons between the 25th and 75th percentile values for those parameters. Similarly, odds ratios were computed for categorical variables, using female gender, the year 2005 and institution A as references. We determined the mean values of all ventilation parameters on a per-year, per-institution basis, in addition to a per-year basis for all institutions for tidal volume and PEEP. Tidal volume per mL of actual body weight and per mL of PBW were compared. Two-tailed, independent t-tests were used for comparison of continuous variables. Data are presented with means and standard deviations, except where otherwise noted. The significance of differences between proportions were compared using z-ratios with two-tailed, independent binomial proportions tests. Statistical inference was performed using a significance level of 0.05. All analyses were performed using R (R Foundation for Statistical Computing, Vienna, Austria).
Results
There were a total of 660,811 adult cases with general anesthesia and tracheal tube placement identified by the collaborating institutions. Of those cases, 400,769 (60.6%) were not excluded by design. Of these patients, 105,229 (26.2%) were excluded due to missing or excluded data, with 295,540 remaining for analysis. Details of the excluded cases are found in Figure 1. The distributions of age, gender, height and weight are noted in Table 1, with an overall mean age of 54 ± 16.5 years, a height of 170.3 ± 9.9 cm, a weight of 84 ± 22.2 kg and a body mass index of 28.9 ± 7.0 kg/m2. 95.7% of the analyzed cases were elective with a mean duration of 171 ± 119.4 minutes.
Table 1.
Total | Center A | Center B | Center C | Center D | Center E | |
---|---|---|---|---|---|---|
(n= 296882) | (n=56740) | (n=108776) | (n=10833) | (n= 58156) | (n= 62377) | |
ASA | ||||||
1 | 26287 | 5825 | 8693 | 1245 | 2118 | 8406 |
2 | 151819 | 23839 | 62195 | 5042 | 23328 | 37415 |
3 | 108011 | 24164 | 35623 | 3766 | 28919 | 15539 |
4 | 10590 | 2889 | 2217 | 741 | 3747 | 996 |
5 | 175 | 23 | 48 | 39 | 44 | 21 |
Emergent case | ||||||
Yes | 284121 | 53058 | 105515 | 9862 | 55868 | 59818 |
No | 12761 | 3682 | 3261 | 971 | 2288 | 2559 |
Height | 117 (162, 177) | 117 (162,177) | 170 (163, 177) | 170 (162, 177) | 172 (163, 180) | 170 (162, 177) |
Weight | 81 (68, 96) | 79 (66, 94) | 82 (68, 97) | 79 (67, 94) | 83 (70, 99) | 79 (66, 93) |
Age | 56 (43, 67) | 54 (42, 66) | 59 (46, 69) | 52 (39, 63) | 54 (42, 64) | 55 (42, 66) |
Duration | 141 (89, 218) | 111 (69, 187) | 172 (118, 252) | 108 (64, 178) | 127 (78, 194) | 129 (84, 205) |
Male gender | 49.18% | 47.93% | 48.85% | 47.92% | 52.28% | 48.23% |
ASA = American Society of Anesthesiologists Physical Status Classification.
Current ventilation approach
There were 58,613 included cases performed during 2013. The median tidal volume for these cases was 7.8 ± 1.5 mL per kg of PBW. 34,751 (59.3%) cases had a median tidal volume less than or equal to 8 mL per kg of PBW. Of the included 2013 cases, 48,808 (83.3%) utilized PEEP with a median value of 5 cm H2O (25th percentile 4, 75th percentile 5). The overall percentage of cases performed in 2013 by PEEP category was 16.5% (none), 22.6% (0–4 cmH2O), 60.7% (5–10 cmH2O), and 0.2% (>10 cmH2O). There were 29,918 (51.0%) cases that had a median tidal volume less than or equal to 8 mL per kg of PBW that also utilized PEEP. As described below, in 2013 all centers (A, B, C, D, E) used PEEP for most cases (58.2%, 99.9%, 92.4%, 72.9%, 79.1% respectively vs. 50%, p < 0.0001), 3 of 5 centers used a median tidal volume less than or equal to 8 mL per kg of PBW for most cases (40.4%, 77.7%, 61.2%, 45.6%, 51.7% respectively vs. 50%, p < 0.0001), and 2 of 5 centers used a median tidal volume less than or equal to 8 mL per kg of PBW and PEEP for most cases (22.7%, 77.6%, 55.4%, 34.4%, 38.5% respectively vs. 50%, p < 0.0001).
Tidal volumes
The median tidal volume mL per kg of PBW was computed for each case, and the means of these tidal volumes were computed for each center and year (Figure 2, top left). Median tidal volume decreased from an average of 9.7 ± 1.9 mL per kg of PBW in 2005 to 7.8 ± 1.5 mL per kg of PBW in 2013 overall (p < 0.0001). Comparing the proportion of cases using a median tidal volume of < 8 mL per kg of PBW between the first and last year of data available at each center revealed an increasing use of median tidal volumes < 8 mL per kg of PBW at centers A (19.6% in 2006 vs. 40.4% in 2013, p < 0.0001), B (45.6% in 2008 vs. 77.7% in 2013, p < 0.0001), D (16.0% in 2005 vs. 45.6% in 2013, p < 0.0001) and E (39.4% in 2006 vs. 51.7% in 2013, p < 0.0001). No statistically significant difference was noted at center C (59.6% in 2011 vs. 61.2% in 2013, p = 0.3), although limited trend data were available at this center. Of all the cases analyzed, 43,934 (14.9%) had a median tidal volume of > 10 mL per kg of PBW, 110,207 (37.3%) had a median tidal volume of 8–10 mL per kg of PBW, and 141,463 had a median tidal volume of < 8 mL per kg of PBW (47.8%), with median tidal volume decreasing over time (Figure 3, top).
Positive end-expiratory pressure
The utilization of PEEP was determined for each case, and the percentage of cases utilizing PEEP was computed for each center and year (Figure 2, upper right). Utilization of PEEP increased from 18.3% to 83.3% (p < 0.0001) over the study period, and was used with a median pressure of 5 cm H2O (4, 5) as seen in Figure 3. Comparing the proportion of cases using PEEP between the first and last year of data available at each center revealed an increasing use of PEEP at centers A (14.8% in 2006 vs. 58.2% in 2013, p < 0.0001), B (73.9% in 2008 vs. 99.9% in 2013, p < 0.0001), D (22.4% in 2005 vs. 72.9% in 2013, p < 0.0001) and E (63.0% in 2006 vs. 79.1% in 2013, p < 0.0001). No statistically significant difference was noted at center C (90.7% in 2011 vs. 92.4% in 2013, p = 0.056).
Additional ventilation parameters
The median respiratory rate was computed for each case, and the means of these values were computed for each center and year (Figure 2, lower left). Median respiratory rate increased significantly over the study period from 8.9 in 2005 breaths per minute to 11.7 breaths per minute in 2013 (p < 0.0001). FiO2 utilization varied by institution (Figure 2, lower right), but did not result in clinically significant differences in SpO2 (Figure 4, middle). Trends of EtCO2 and peak inspiratory pressure similarly demonstrated institutional variation (Figure 4, bottom and top).
Predictors of lower tidal volumes
All of the pre-specified factors were significantly related to the tidal volumes utilized (Figure 5). The R2 for the proportional odds model was 0.470. Height had the largest odds ratio for receiving lower tidal volumes (odds ratio (OR) 10.83, 95% confidence interval [10.50, 11.16]), followed by institution (lowest OR 0.98 [0.96, 1.00], highest 9.63 [9.41, 9.86]), year (lowest OR 1.32 [1.21, 1.44], highest OR 6.31 [5.84, 6.82]), male gender (OR 1.10 [1.07, 1.12]), and weight (OR 0.30 [0.29, 0.31]). Modeling with restricted spline curves allowed for visualization of non-linear relationships between the probability of receiving lower tidal volume ventilation and each previously identified risk factor for higher tidal volume ventilation; no specific cut-off for increased risk was identified for weight or height (Additional file 1). Factor associated with higher tidal volumes included female gender, increased body weight, decreased stature and cases performed in earlier years. Significant differences were also noted by institution, which varied from an OR of 0.98 (0.96, 1.00) for institution D compared with institution A, to an OR of 9.63 (9.41, 9.86) for institution B compared with institution A.
Comparison of actual and predicted body weight
The overall mean for median tidal volumes across all institutions and years was 8.3 ± 1.8 mL per kg of PBW, compared to an overall mean of 6.3 ± 1.6 mL per kg of actual body weight (Additional file 2). This difference was statistically significant (p < 0.0001).
Discussion
We confirmed our hypothesis that most (59.3%) anesthetics are currently being performed with tidal volumes below 8 mL per kg of PBW in U.S. academic medical centers. We further confirmed that most (83.3%) cases received PEEP. Approximately half (51%) of current anesthetics utilized both tidal volumes below 8 mL per kg of PBW and PEEP. This analysis has revealed a significant trend toward decreased tidal volumes relative to PBW and an increased utilization of PEEP, with a rise in respiratory rate. The previously identified predictors [17] for non-compliance with lower tidal volume ventilation including decreased height, female gender and higher body weight were validated, and significant effects from time and institution were noted.
It is possible that the changes we observed in the intraoperative period are a reflection of broader changes in ventilation strategy both outside and inside of the operating room. Following the ARDSnet trial which demonstrated a mortality benefit from decreased tidal volumes and the concomitant application of PEEP to ICU patients with established lung injury, protective lung ventilation has gained increasing acceptance. While historically higher tidal volumes (>10 mL per kg of PBW) were chosen to prevent atelectasis, data from animal models [5-7] and humans [8] have shown an increase in inflammatory markers associated with higher tidal volumes used without PEEP, although these effects have not been consistently observed [18].
A recent randomized controlled trial of intraoperative ventilation strategies conducted in France demonstrated a mortality benefit when using lower tidal volumes (6–8 mL per kg of PBW) with PEEP compared to a control group that utilized higher tidal volumes (10–12 mL per kg of PBW) without PEEP [15]. However, as our data demonstrate, the ventilation strategy that the control group received in that trial does not reflect the current practices for intraoperative ventilation in major U.S. academic medical centers. Our findings indicate that the most patients in major U.S. academic medical centers are currently receiving intraoperative ventilation strategies consistent with protective lung ventilation with respect to lower tidal volumes and usage of PEEP, although our findings also demonstrate that a large proportion of these patients are not receiving both, and a significant number of patients receive neither. While it is premature to conclude that intraoperative protective lung ventilation strategies may be indicated for patients undergoing surgical procedures, there is a growing body of evidence to suggest that certain patient conditions and surgical procedures are associated with higher incidences of postoperative pulmonary complications [19].
While the observed trend to lower tidal volumes and consistent use of PEEP likely reflects the increased awareness of the benefits of minimizing mechanical injury to the lungs, the exact settings to achieve that goal within the operative context are largely unknown. Direct application of ICU findings to the OR setting is probably unsuitable given the mechanical differences between injured and non-injured lungs, in addition to the potential influence of inflammatory mediators and ongoing lung injury from infection. Although surgical inflammation may predispose the lungs to injury, this hypothesis is untested. Accordingly, additional research using control groups that reflect current practice is needed to determine optimal intraoperative ventilation strategies.
Our finding of substantial variability amongst the centers included in this study indicates a lack of clear evidence and guidelines to precisely direct clinical use of intraoperative mechanical ventilation. It further implies that whereas a global trend exists for ventilation strategies, the specific ventilator settings used are also a matter of local practice, even in centers where the best scientific information is readily available. Together, these findings suggest that not only is better evidence needed to help guide clinical practice, but also that education will be an essential component in the effort to implement best ventilator practice guidelines at all levels.
Our study has a number of limitations. We examined only U.S. academic medical centers. Consequently, we are unable to determine if the current practice patterns observed are applicable in community hospitals, same-day surgical centers or other settings where intraoperative mechanical ventilation occurs. However, as these centers are representative of our nation’s training pipeline, it is likely that trainees, including anesthesiology residents and student certified registered nurse anesthetists, who graduate from these programs follow similar practices. Additionally, we excluded procedures where there might be additional, procedure-related considerations in choosing a ventilation strategy, specifically neurosurgical procedures, cardiovascular procedures and procedures using laparoscopy. Our conclusions thus do not generalize to those procedures. We further excluded pediatric patients, limiting our analysis to adult patients. We studied only patients who underwent general anesthesia with tracheal intubation and so are not able to determine what trends may or may not have occurred with other airway approaches such as supraglottic airway devices. As our data were comprised of millions of data points across many institutions there are likely data artifacts that remained present despite best efforts to validate these data and to exclude cases with any invalid data. These data quality concerns were mitigated by choosing statistical analysis techniques that are robust with respect to artifacts that manifest themselves in the extremes of data values. Additionally, we limited the analysis to cases that were at least 30 minutes in length with corresponding automated measurements of tidal volume, thus focusing our study on the maintenance phase of anesthesia where the ventilation strategy is less likely to be impacted by preparation for extubation. Finally, our study focused on tidal volume and PEEP only, and did not examine in detail other aspects of ventilator management that could be considered part of lung protective ventilation, including FiO2, peak inspiratory pressure, plateau pressure and mean airway pressure.
Conclusion
In conclusion, we have analyzed the intraoperative ventilation approach from a sample of adult, non-cardiothoracic and non-neurosurgical anesthetics from U.S. academic medical centers, which was significant for a trend towards increasing usage of PEEP and decreasing tidal volume over time. Most anesthetics in these institutions are currently conducted with tidal volumes of less than 8 mL per kg of PBW, most anesthetics are also performed with PEEP and approximately half are performed with both.
Acknowledgements
The authors would like to thank Milcho Niklov and Geoff Counihan at Massachusetts General Hospital, Betsy Hale at Duke University, Nageswar R. Madde at Mayo Clinic, Ken Bullard at University of Colorado School of Medicine, and Michaelene Johnson and Karen McCarthy at Vanderbilt University, for their collective technical assistance in data retrieval.
This perioperative medical investigation was funded by departmental sources and, in part, the Foundation for Anesthesia Education and Research (FAER) (to Drs. Wanderer and Fernandez-Bustamante), the Anesthesia Quality Institution (Dr. Wanderer) and NHLBI Grant R01 HL121228 (Dr. Vidal Melo).
Abbreviations
- ARDS
Acute respiratory distress syndrome
- ASA
American society of anesthesiologists
- AIMS
Anesthesia information management system
- CPT
Current procedural terminology
- EtCO2
End-tidal carbon dioxide
- FiO2
Fraction of inspired oxygen
- PBW
Predicted body weight
- PEEP
Positive end-expiratory pressure
- RR
Respiratory rate
- OR
Odds ratio
- SpO2
Oxygen saturation
Additional files
Footnotes
Competing interests
The authors declare that they have no competing interests.
Authors’ contributions
JPW contributed to the study design, carried out the statistical analysis and wrote the manuscript. All authors read and approved the final manuscript. JME contributed to the study design and critically reviewed the manuscript. RHE performed the data retrieval at his institution, contributed to the statistical analysis and the study design, and critically reviewed the manuscript. DJK contributed to the study design and critically reviewed the manuscript. RRB contributed to the study design and critically reviewed the manuscript. AFB contributed to the study design and critically reviewed the manuscript. MFVM contributed to the study design and critically reviewed the manuscript. JMB contributed to the study design and critically reviewed the manuscript. All authors read and approved the final manuscript.
Authors’ information
This work has been presented at the ASA Annual Meeting 2014 Journal Symposium. This work is to be attributed to the Department of Anesthesiology, Vanderbilt University.
Contributor Information
Jonathan P Wanderer, Email: jonathan.p.wanderer@vanderbilt.edu.
Jesse M Ehrenfeld, Email: jesse.ehrenfeld@vanderbilt.edu.
Richard H Epstein, Email: richard.epstein@jefferson.edu.
Daryl J Kor, Email: Kor.Daryl@mayo.edu.
Raquel R Bartz, Email: raquel.bartz@duke.edu.
Ana Fernandez-Bustamante, Email: fernanan@ucdenver.edu.
Marcos F Vidal Melo, Email: VidalMelo.Marcos@mgh.harvard.edu.
James M Blum, Email: jmblum@emory.edu.
References
- 1.Schultz MJ, Haitsma JJ, Slutsky AS, Gajic O. What tidal volumes should be used in patients without acute lung injury? Anesthesiology. 2007;106(6):1226–31. doi: 10.1097/01.anes.0000267607.25011.e8. [DOI] [PubMed] [Google Scholar]
- 2.Yang M, Ahn HJ, Kim K, Kim JA, Yi CA, Kim MJ, et al. Does a protective ventilation strategy reduce the risk of pulmonary complications after lung cancer surgery? A randomized controlled trial. Chest. 2011;139(3):530–7. doi: 10.1378/chest.09-2293. [DOI] [PubMed] [Google Scholar]
- 3.Weingarten TN, Whalen FX, Warner DO, Gajic O, Schears GJ, Snyder MR, et al. Comparison of two ventilatory strategies in elderly patients undergoing major abdominal surgery. Br J Anaesth. 2010;104(1):16–22. doi: 10.1093/bja/aep319. [DOI] [PubMed] [Google Scholar]
- 4.Sundar S, Novack V, Jervis K, Bender SP, Lerner A, Panzica P, et al. Influence of low tidal volume ventilation on time to extubation in cardiac surgical patients. Anesthesiology. 2011;114(5):1102–10. doi: 10.1097/ALN.0b013e318215e254. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Costa EL, Musch G, Winkler T, Schroeder T, Harris RS, Jones HA, et al. Mild endotoxemia during mechanical ventilation produces spatially heterogeneous pulmonary neutrophilic inflammation in sheep. Anesthesiology. 2010;112(3):658–69. doi: 10.1097/ALN.0b013e3181cbd1d4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Wellman TJ, Winkler T, Costa EL, Musch G, Harris RS, Zheng H, et al. Effect of local tidal lung strain on inflammation in normal and lipopolysaccharide-exposed sheep. Crit Care Med. 2014;42(7):e491–500. doi: 10.1097/CCM.0000000000000346. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.de Prost N, Costa EL, Wellman T, Musch G, Tucci MR, Winkler T, et al. Effects of ventilation strategy on distribution of lung inflammatory cell activity. Crit Care. 2013;17(4):R175. doi: 10.1186/cc12854. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Serpa Neto A, Cardoso SO, Manetta JA, Pereira VG, Espósito DC, Pasqualucci Mde O, et al. Association between use of lung-protective ventilation with lower tidal volumes and clinical outcomes among patients without acute respiratory distress syndrome: a meta-analysis. JAMA. 2012;308(16):1651–9. doi: 10.1001/jama.2012.13730. [DOI] [PubMed] [Google Scholar]
- 9.Carney D, DiRocco J, Nieman G. Dynamic alveolar mechanics and ventilator-induced lung injury. Crit Care Med. 2005;33(3):S122–8. doi: 10.1097/01.CCM.0000155928.95341.BC. [DOI] [PubMed] [Google Scholar]
- 10.Wrigge H, Uhlig U, Zinserling J, Behrends-Callsen E, Ottersbach G, Fischer M, et al. The effects of different ventilatory settings on pulmonary and systemic inflammatory responses during major surgery. Anesth Analg. 2005;98(3):775–81. doi: 10.1213/01.ane.0000100663.11852.bf. [DOI] [PubMed] [Google Scholar]
- 11.Kor DJ, Lingineni RK, Gajic O, Park PK, Blum JM, Hou PC, et al. Predicting risk of postoperative lung injury in high-risk surgical patients: a multicenter cohort study. Anesthesiology. 2014;120(5):1168–81. doi: 10.1097/ALN.0000000000000216. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Goldenberg NM, Steinberg BE, Lee WL, Wijeysundera DN, Kavanagh BP. Lung-protect ventilation in the operating room: time to implement? Anesthesiology. 2014;121:184–8. doi: 10.1097/ALN.0000000000000274. [DOI] [PubMed] [Google Scholar]
- 13.Wanderer JP, Blum JM, Ehrenfeld JM. Intraoperative low-tidal-volume ventilation. N Engl J Med. 2013;369(19):1861. doi: 10.1056/NEJMc1311316. [DOI] [PubMed] [Google Scholar]
- 14.Hess DR, Kondili D, Burns E, Bittner EA, Schmidt UH. A 5-year observational study of lung-protective ventilation in the operating room: a single-center experience. J Crit Care. 2013;28(4)(533):e9–15. doi: 10.1016/j.jcrc.2012.11.014. [DOI] [PubMed] [Google Scholar]
- 15.Futier E, Constantin JM, Paugam-Burtz C, Pascal J, Eurin M, Neuschwander A, et al. A trial of intraoperative low-tidal-volume ventilation. N Engl J Med. 2013;369:428–37. doi: 10.1056/NEJMoa1301082. [DOI] [PubMed] [Google Scholar]
- 16.The Acute Respiratory Distress Syndrome Network Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000;342:1301–8. doi: 10.1056/NEJM200005043421801. [DOI] [PubMed] [Google Scholar]
- 17.Fernandez-Bustamante A, Wood CL, Tran ZV, Moine P. Intraoperative ventilation: incidence and risk factors for receiving large tidal volumes during general anesthesia. BMC Anesthesiol. 2011;11:22. doi: 10.1186/1471-2253-11-22. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Fernandez-Bustamante A, Klawitter J, Repine JE, Agazio A, Janocha AJ, Shah C, et al. Early effect of tidal volume on lung injury biomarkers in surgical patients with healthy lungs. Anesthesiology. 2014;121(3):469–81. doi: 10.1097/ALN.0000000000000301. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Canet J, Gallart L, Gomar C, Paluzie G, Vallès J, Castillo J, et al. Prediction of postoperative pulmonary complications in a population-based surgical cohort. Anesthesiology. 2010;113(6):1338–50. doi: 10.1097/ALN.0b013e3181fc6e0a. [DOI] [PubMed] [Google Scholar]