Abstract
The origin of terrestrial tetrapods was a key event in vertebrate evolution, yet how and when it occurred remains obscure, due to scarce fossil evidence. Here, we show that the study of palaeopathologies, such as broken and healed bones, can help elucidate poorly understood behavioural transitions such as this. Using high-resolution finite element analysis, we demonstrate that the oldest known broken tetrapod bone, a radius of the primitive stem tetrapod Ossinodus pueri from the mid-Viséan (333 million years ago) of Australia, fractured under a high-force, impact-type loading scenario. The nature of the fracture suggests that it most plausibly occurred during a fall on land. Augmenting this are new osteological observations, including a preferred directionality to the trabecular architecture of cancellous bone. Together, these results suggest that Ossinodus, one of the first large (>2m length) tetrapods, spent a significant proportion of its life on land. Our findings have important implications for understanding the temporal, biogeographical and physiological contexts under which terrestriality in vertebrates evolved. They push the date for the origin of terrestrial tetrapods further back into the Carboniferous by at least two million years. Moreover, they raise the possibility that terrestriality in vertebrates first evolved in large tetrapods in Gondwana rather than in small European forms, warranting a re-evaluation of this important evolutionary event.
Introduction
A pivotal phase in vertebrate history was the evolution of tetrapods from sarcopterygian fish, and their subsequent colonization of land [1]. In addition to radical anatomical changes [2–8], it encompassed a profound shift in functional morphology and behaviour, due to the increased effect of gravity out of the support of water. However, exactly how and when tetrapods adapted to the requirements of a terrestrial lifestyle remains elusive. Based on current understanding of Late Devonian tetrapods, the advent of vertebrate terrestrialization is inferred to have taken place during the Early Carboniferous [1], yet tetrapod fossils are extremely scarce from the first 30 million years of this period, approximately 359–329 million years ago (mya). The oldest known incontrovertibly terrestrial tetrapods are small animals from the Late Viséan of Scotland [9,10], approximately 327–331 mya, but a global scarcity of tetrapod fossils from earlier in the Carboniferous hinders an assessment of how and when the colonization of land began [1,11,12].
Deriving from the mid-Viséan (333 mya) of Queensland, Australia [13,14], the primitive stem tetrapod Ossinodus pueri (Fig 1a) is of critical importance to interpreting the evolution of terrestrial tetrapods. Along with the Late Devonian Tulerpeton [15], Ossinodus is remarkable among early stem tetrapods in the high degree of ossification in its appendicular elements, comparable to that of many early amniotes [14,16]. All Ossinodus bones have been recovered from a single site preserving multiple individuals of varying size [14], and all stem tetrapod bones from this site are regarded as belonging to O. pueri, based on a similar pattern of ornamentation on the recovered dermal cranial bones [14,16]. Among the numerous cranial and postcranial elements recovered for Ossinodus is a fractured right radius, which is the oldest known tetrapod palaeopathology [17] (Fig 1b–1e). The presence of a callus shows that healing had commenced, but given that the fracture can still be observed in X-radiographs of the fossil [17], this indicates that the radius had only partially healed when the individual died. Having fractured when the individual was alive, it can therefore provide insight into stem tetrapod lifestyle and behavior [18].
The fossil’s excellent preservation presents the unique opportunity to analyze the fracture’s three-dimensional geometry via high-resolution computed tomographic (CT) scanning. The CT scanning also permits the assessment of the internal microstructure of the fossil, such as that of cancellous bone. Additionally, we employed high-resolution, three-dimensional finite element analysis (FEA), an approach that has been used to accurately simulate structural mechanics in both living and extinct taxa [19,20], to determine the conditions under which fracturing occurred. This provides direct evidence of lifestyle in a stem tetrapod, which has important implications for understanding the physiological, temporal and biogeographical context under which terrestriality in vertebrates evolved.
Materials and Methods
No permits were required for the described study, which complied with all relevant regulations.
Data acquisition
The fractured right radius of Ossinodus, Queensland Museum Fossil specimen (QMF) 37451, was scanned using a Bioscan NanoPET/CT scanner. The settings used are as follows: helical scan method, 1100 ms exposure time, 65 kV peak voltage, nominal isotropic voxel resolution of 65 μm. In order to achieve adequate spatial resolution (i.e., a resolution of 65 μm), the fossil was scanned in three parts along its long axis, and the resulting scan series rejoined in Avizo 7.0 (Visualization Sciences Group, USA).
Analysis of cancellous bone architecture
The trabecular architecture of cancellous bone was most clearly resolved in the CT scans of the proximal end of the radius. This region was quantitatively analyzed for architectural anisotropy using the mean intercept length method as implemented in the software Quant3D [21]. The region of bone analyzed was centrally located in the proximal end and occupied a volume of dimensions 5.92 × 6.50 × 4.23 mm. The entire volume was analyzed using the following settings in Quant3D: adaptive iterative thresholding, 2000 points and 2049 uniform orientations with random rotation and dense vectors. The resulting mean intercept length tensor was used to produce a fabric ellipsoid with principal axes in Rhinoceros 4.0 (McNeel, USA).
Image processing and analysis
The CT scans were visualized, segmented, three-dimensionally modelled and analyzed in Mimics 14.0 (Materialize NV, Belgium), Rhinoceros and the open source software ImageJ 1.47 (http://rsb.info.nih.gov/ij/). The pathological fracture was identified in the scans as a sharp discontinuity with a long, linear geometry, manifest as an area much darker (i.e., lower greyscale values) than the surrounding bone (Fig 2); its orientation and extent was subsequently mapped out manually. It was distinguished from post-mortem, preservational fractures on the basis that preservational fractures extended to one or more areas at the bone surface, and that they were typically wider (several pixels across) than the pathologic fracture (generally two pixels across). Identifying the orientation of the fracture, and the sense of fracture displacement, allows for the loading conditions under which fracturing occurred to be reconstructed.
In order for a finite element model of the radius of Ossinodus to be produced, the bone’s morphology prior to fracturing had to be reconstructed. This required that the following features of the fossil be digitally ‘corrected’ in the CT scans, using Mimics 14.0 (Figs 2 and 3):
The healing callus was removed, identified on the basis of its internal microstructure. The microstructure of the callus was much finer and grainier than that of the normal, nonpathologic bone; it also showed little trace of trabeculae. Removing the callus, however, also removes what was once original bone. Therefore, once it was removed, the original external outline of the bone had to be restored in that area; this was primarily achieved by using the concentric pattern of density change within the bone as a guide.
The proximal and distal ends of QMF 37451 are abraded to different degrees (Fig 3). These were restored to achieve a complete bone, partly via comparison to the morphologies of the radii of other, phylogenetically close, Early Carboniferous tetrapods [22,23]. The nature of cancellous bone within the missing parts could not be reconstructed, because there are no other known fossil radii of Ossinodus to obtain the information for those missing parts.
Preservational (taphonomic) fractures were removed by ‘filling in’ via extrapolation from adjacent regions of bone, using the appropriate density of bone (see below).
To enable the development of a heterogenous finite element model, the reconstructed morphology of the pre-fractured radius was segmented into both cortical and cancellous bone components (Fig 2). Cortical bone was segmented using a combination of thresholding tools and manual segmentation. The remaining volume of the bone (cancellous bone) was segmented into four different components with different bulk densities, via thresholding of voxel greyscale values. The range of greyscale values used for separating out each component were chosen on the qualitative appearance of the CT data; the separation used was deemed to best represent the structural patterns present, ensuring that the model subsequently generated was as realistic as possible.
Finite element model construction
In order to determine how and with what magnitude force the radius of Ossinodus would have fractured, the CT scan data was used to develop a high-resolution, three-dimensional, finite element model of the bone’s pre-fractured morphology in Strand7 2.4.4 (Strand7 Pty Ltd, Australia). The fossil’s preservation allowed for cortical bone and different components of the cancellous bone to be modelled separately based on density differences, thus enabling patterns of variation in material properties in the original, living bone to be accounted for. However, since a small part of the fossil was missing, knowledge of structural and material heterogeneity within the cancellous bone is incomplete. Thus, in the final model used, all cancellous bone elements were assigned a single set of material properties, distinct from those assigned to the cortical bone elements; each component (cortical and cancellous) was modelled as a homogenous material. This model is referred to herein as the ‘complete homogenous model’ (Fig 4a, Table 1).
Table 1. Material properties assigned to the elements in the three finite element models.
Material | Density, ρ (g/cm3) | Young’s Modulus, E (MPa)* | Poisson’s Ratio, ν |
---|---|---|---|
Cortical bone | 2.06 | 20,000 | 0.4 |
Cancellous bone density 1† | 1.6 | 17,500 | 0.3 |
Cancellous bone density 2† | 1.4 | 15,000 | 0.3 |
Cancellous bone density 3† | 1.2 | 12,000 | 0.3 |
Cancellous bone density 4† | 1.1 | 11,000 | 0.3 |
Homogenous cancellous bone‡ | 1.3 | 13,500 | 0.3 |
Articular surfaces | 1.1 | 10,000 | 0 |
All elements were low-order tetrahedral bricks except for the network of tessellated beams representing the articular surfaces. Values for cortical bone from [24–27].
* Values rounded to the nearest 0.5 GPa, to allow for uncertainty
† Only present in the incomplete heterogenous model
‡ Only present in the incomplete and complete homogenous models
To assess the possible effects of modelling the cancellous bone as a single homogenous volume, two further finite element models of the preserved part of the fossil were produced for comparative analysis (Fig 4), both without any of the reconstructed parts of the proximal and distal ends of the bone. The purpose of these two models was to assess whether the representation of a spatially and compositionally heterogenous material as a single, homogenous volume (as in the complete homogenous model) would introduce significant error into the analysis of fracture mechanics. Thus, in one model, the preserved cancellous bone was represented by a single, homogenous material (with material properties distinct from those assigned to the cortical bone elements); this is herein referred to as the ‘incomplete homogenous model’ (Fig 4b, Table 1). In the other, the preserved cancellous bone was represented by four separate densities and material properties (corresponding to the four components produced in the initial segmentation); this is herein referred to as the ‘incomplete heterogenous model’ (Fig 4c and 4d, Table 1). Comparative FEA of these two models would elucidate any error introduced by the simplified representation of cancellous bone, since the only difference between the two was how the cancellous bone was represented.
To produce the complete homogenous finite element model, a rendered surface mesh of the reconstructed (pre-fracture) radius was produced in Mimics 14.0. This was then exported to Avizo 7.0, where a solid mesh of 1,189,119 low-order tetrahedral brick elements was generated. The solid mesh was re-imported into Mimics 14.0, where the segments of cortical and (homogenous) cancellous bone were used to assign different material properties to the constituent brick elements of the mesh, via the ‘mask intersection’ method built into Mimics 14.0. Finally, this was then imported into Strand7 2.4.4. A similar procedure was employed in generating the incomplete heterogenous and incomplete homogenous finite element models; both consisted of 1,080,638 low-order tetrahedral brick elements.
In lieu of a more complete understanding of the variation in bone material property anisotropy in extant tetrapods, all elements were modelled as isotropic materials, that is, they respond the same way to loading regardless of the direction the load comes from.
Cortical bone elements in all three models were assigned the same set of material properties (Table 1). Values for physical density (ρ), Young’s modulus (E) and Poisson’s ratio (ν) were drawn from many studies of the main limb bones of a wide variety of animals, mostly mammals and birds [24–27]. The values used here are approximately the modal values reported for each property, and they represent a conservative first estimate.
To accurately model the cancellous bone, a more involved approach was required. First, the patterns of variation in physical density in the original, living bone had to be determined. In living bone, the greyscale (Hounsfield) values in CT scans can be used to directly determine approximate physical density; however, in this case, the calculated physical densities will be that of the fossil, not the original, living bone. Nevertheless, the patterns of variation in density can be reasonably assumed to be representative of the patterns of density variation in the original bone, due to the fossil’s excellent preservation. To ensure a realistic designation, the resulting total mass of the bone in the incomplete heterogenous model was calculated following density assignment. The densities used in the final model (Table 1) yielded a total mass of approximately 4.3 g, which is a reasonable estimate of the mass of the fossil specimen if it were living bone, assuming a bulk long-bone density of 1.4 g/cm3 [24]. For both complete and incomplete homogenous finite element models, the physical density of the cancellous bone was the volume-weighted mean of the four densities used in the heterogenous model. Once physical densities had been determined, Young’s modulus was assigned to each element in the three models, via a regression equation derived from the data presented by [28], E = 0.001ρ 1.3266, where E is in GPa and ρ is in kg/m3. Lastly, elements were assigned values of Poisson’s ratio. Experimentally determined values for ν in living cancellous bone are quite variable, and it is unclear as to how this variation correlates to variation in density [29]. Thus, a conservative approach was taken here, whereby all cancellous bone elements in each model were assigned a value of ν = 0.3 [30], pending further data.
To represent the effects of articular cartilages at the proximal and distal ends of the radius, the inferred articular surfaces (reconstructed for the distal end) were modelled as a tessellated network of stiff beam elements. This helps to reduce the incidence of point artifacts in the results of a FEA [28,30].
Comparative FEA of incomplete heterogenous and homogenous models
To investigate the potential error introduced by modelling a compositionally and spatially heterogenous volume of cancellous bone as a single, homogenous volume, we tested a number of different loading regimes applied to the incomplete heterogenous and incomplete homogenous finite element models:
Uniaxial compression directed parallel to the bone’s long axis, with loads applied to the proximal end.
Uniaxial tension directed parallel to the bone’s long axis, with loads applied to the proximal end.
Uniaxial torsion about the long axis of the bone, with a positive moment applied at the proximal end.
Anteroposterior bending, with an anteriorly directed force applied at the posterior surface of the bone at its midshaft.
Mediolateral bending, with a medially directed force applied to the lateral surface of the bone at its midshaft.
The first three models were restrained in translation at a small number of nodes in the centre of the distal end; the last two were restrained in translation at a small number of nodes in the centre of both ends. Each model was analyzed as a linear static system; hence, the magnitude of applied forces in a given loading regime is unimportant, only that they are consistent between models.
FEA of complete homogenous radius model
Based on the identified orientation and nature of displacement of the fracture (see Results and Discussion), the complete homogenous finite element model was used to identify the loading regime that caused the radius to fracture. To prevent free-body movement of the model under loading, the distal end was restrained in translation at a small number of nodes in the centre. Given that the fracture and bone presents features associated with impact-type situations (trauma), rather than those associated with bone fatigue (stress fractures), tendon avulsion, or prior pathology [17,18], all force vectors used in a given loading regime (simulating the external, fracture-causing load) were of the same magnitude and orientation. The applied loads did not incorporate any ‘background loading’ as might occur during normal use, such as that produced by muscular action. This is because strain in the area of interest (the proximal end of the bone) is typically very low during normal use [31]. Hence, strain results in the proximal end of the model will almost completely reflect the applied external loads.
To determine which loading regime was responsible for the fracture, each model was analyzed as a linear static system, and the results were assessed according to two criteria:
Strain field pattern: the correct loading regime would result in regions of high von Mises strain (a measure of distortion) which are aligned with the orientation of the fracture and are spatially restricted to the extent of the fracture. It has been suggested that von Mises stress is a good predictor of failure in bone [30], although in a linearly elastic model it will show the same pattern as its strain equivalent.
Stress field pattern: the desired loading regime will produce a stress field in which the orientation of maximum (σ 11), minimum (σ 33), and intermediate (σ 22) principal stresses in the region of the fracture are consistent with shear fracturing along the orientation of the fracture plane and in the correct direction of displacement [32]. In particular, σ 11 is at a high angle to the fracture plane, σ 33 is at a low angle to the fracture plane, and σ 22 is parallel to the fracture plane and perpendicular to the direction of slip.
The identification of the loading regime that satisfied these criteria proceeded in an iterative ‘trial and error’ fashion. Recognizing that the mode of fracture (see Results and Discussion) required a force applied somewhere on the proximolateral end of the bone and with a component directed distally [32–34], this was used as an initial starting point for force vector orientation and area of application in the FEA. The results from this loading regime were used to guide the set-up of the next loading regime (i.e., alter the orientation of the force vectors, or its area of application, or both), and so on until a solution was achieved.
Results and Discussion
Fracture and callus
The CT scans reveal a single fracture plane in the proximal end of the radius (Fig 5a–5h). The fracture lies just beneath the endosteal surface, and is parabolic in mediolateral view and almost concentric with the margins of the bone in transverse section. The healing process has produced a callus, which is perforated by six sizeable lesions (pits) that occasionally form subsurface canals (Fig 5i–5l), indicating post-traumatic infection of the bone, with pus formation (suppurative osteomyelitis) [35]. The callus is demarcated distally by a pronounced groove, where the fracture nears the bone surface (Fig 5b and 5d).
Osteological microstructure
The architecture of cancellous bone in the proximal end of the radius has a preferred trabecular orientation (Fig 5m and 5n), with a degree of anisotropy (the relative magnitudes of primary and tertiary material eigenvectors [21]) of 1.27. Moreover, the primary axis of the fabric ellipsoid is almost perfectly aligned with the bone’s long axis (Fig 5o): the axis of primary trabecular alignment is essentially parallel to the long axis of the bone. This suggests that the radius underwent remodelling throughout life as a response to frequent, axially directed loads [25,36–39]. This would occur if the animal spent considerable time on land with the limbs in a sprawling position, and the forearm held approximately vertically to support the animal’s weight. This interpretation receives further support from the morphology of a single nutrient foramen which pierces the distal medial surface of the radius (Fig 5p and 5q). The low-angle of entry (~20°) into the bone would theoretically reduce potentially dangerous stress concentrations produced under axial loading [25], thus serving as an additional adaptation to weight support.
Heterogenous versus homogenous finite element models
The comparative FEA between the incomplete heterogenous and incomplete homogenous finite element models revealed no significant difference in their biomechanical performance under each loading regime tested (Fig 6), consistent with the results of previous work [40]. Both models predicted very similar stress and strain field patterns; furthermore, comparison of mean von Mises brick strain [28] between the two models for each loading regime showed very small differences in model results (Table 2), with a maximum difference of ~1.5%. Importantly, this means that a complete model with a homogenous volume of cancellous bone captures the biomechanical behaviour of the bone with sufficient accuracy to address the question of fracture mechanics in the radius of Ossinodus.
Table 2. Results of comparative FEA between heterogenous and homogenous models.
Loading regime | Heterogenous (με) | Homogenous, (με) | Difference in means relative to heterogenous (%) |
---|---|---|---|
Uniaxial compression | 24.010 [243.416] | 24.134 [232.951] | 0.515 |
Uniaxial tension | 24.010 [243.416] | 24.134 [232.951] | 0.515 |
Uniaxial torsion | 42.002 [336.307] | 42.649 [325.280] | 1.541 |
Anteroposterior bending | 18.195 [49.845] | 18.421 [50.137] | 1.243 |
Mediolateral bending | 21.427 [26.759] | 21.519 [27.810] | 0.426 |
Outlines comparison between von Mises brick strain results (reported as mean [standard deviation]) for both the incomplete heterogenous and incomplete homogenous models under each of the five test loading regimes.
Evaluation of fracture scenario
The orientation of the fracture and the nature of the surrounding bone allows for the sense of displacement along the fracture to be determined. Given that the fracture nears the bone surface at a distinct groove in the fossil (Fig 5b and 5d), this indicates distal displacement of an external fragment (or fragments) of bone, which subsequently healed out of position (Fig 7a).
In the FEA of the complete homogenous model, a total of nineteen different loading regimes were tested before the predicted stress and strain results were deemed to satisfy the two criteria of strain and stress field patterns. The loading regime which would have resulted in fracture was found to be a force applied to almost the entire width of the proximal-most lateral surface of the bone; this force was essentially axially directed, towards the distal end (Fig 7b–7d). This loading regime produced the expected patterns of localized high von Mises strain and a principal stress field consistent with the hypothesized mode of displacement (Fig 7e–7k).
Since the model was analyzed as a linear static system, the absolute magnitude of applied forces in the simulation was unimportant; nevertheless, the simulation does facilitate estimation of the magnitude required for fracture. In the simulation, the applied force which satisfied the above criteria had a magnitude of 56.1 Newtons (N), and peak von Mises strain in the fracture zone in this solution was approximately 300 με (Fig 7e–7h). The yield strain of bone may be assumed to be 6,000 με [25]. In a linear system, strain is directly proportional to stress, and hence force; therefore, the actual force required for fracture is
Dividing by gravitational acceleration (F = ma g, where a g = 9.8 m/s2), this is equivalent to a loading mass of m = 114 kg.
To express this loading mass in terms of the Ossinodus individual concerned requires that its body mass is known. Given that Ossinodus likely had body proportions similar to that of many other early tetrapods from the Late Devonian to Early Carboniferous, especially Pederpes (Fig 1a; see also [16,22,41]), the individual the radius belonged to is estimated as having a total (snout—tail) length of 1–1.5 m. (The range in the estimate given here is due in large part to uncertainty in the relative length of the tail; see [41].) The mass of this individual may be estimated via comparison to the Chinese giant salamander, Andrias davidianus, which reaches total lengths of 2 m and masses of 50 kg [42], and has body proportions similar to that of many early tetrapods. For an Ossinodus of length l Ossinodus = 1–1.5 m, its mass m Ossinodus would hence be
To be conservative (in terms of calculating the relative magnitude of the impact force) the mass of the Ossinodus individual is estimated to be 10–25 kg. Expressed in terms of the animal’s body weight, the fracturing force is therefore
Crucially, forces of this large relative magnitude are very difficult to achieve in water, because of drag and the cushioning effect water has on impacting bodies [27,43]. In contrast, these large forces could easily be experienced on land, such as falling off a log or rock, or being caught in the collapse of unstable ground.
The plausibility of a fall scenario is demonstrated here using basic Newtonian mechanics. Consider a situation in which an Ossinodus of mass m = 25 kg falls some distance s h, experiencing an impact force of F = 1,120 N. Important to the force experienced is the distance s d over which the body decelerates from free-fall to a standing stop on the ground (with deceleration a), which may be assumed to be approximately equal to the dorsoventral depth of the animal’s body, say 0.15 m [16]. Slowing down to a final velocity of v f = 0 m/s from free-fall, the maximum free-fall velocity reached prior to deceleration, v max, is:
The height of free-fall can now be calculated, assuming a standing start (v i = 0 m/s):
That is, a 25 kg Ossinodus would only have to fall 85 cm to sustain the impact force of 1,120 N sufficient to fracture its radius: the large forces required for fracture could be easily achieved in a fall on land. This is the minimum distance required to fall, based on the uppermost limit of estimated body mass (25 kg). If a lighter animal was involved, the corresponding fall distance would increase; for example, if a 15 kg animal were involved (and the s d is scaled appropriately to reflect the smaller depth of the animal’s body), it would have to fall about 110 cm. As all of the estimations and assumptions underpinning the above calculations have been made on the conservative side (e.g., the purposeful overestimation of body mass), we are confident that the force required for the radius to fracture in the manner it did was very large, and that a fall on land is entirely possible from a mechanical perspective. Consistent with a fall hypothesis, the mode of displacement along the fracture (Fig 7a) is very similar to that of proximal radius fractures in humans which result from a fall onto an outstretched arm, where the humerus impacts upon the radial head [33,34]. Since the force required for fracture in the FEA was a distributed load, this excludes the possibility that it resulted from a bite (predatory or otherwise), where an impacting tooth would produce a spatially concentrated load. We therefore conclude that the most plausible explanation for the fracture in the radius of Ossinodus was that the animal was living on land and sustained a fall.
Conclusions
This study demonstrates the potential utility of a combined palaeopathological-biomechanical approach for elucidating the lifestyle of extinct organisms. In addition to the results of FEA, we have observed two anatomical features in the radius of Ossinodus—cancellous bone architecture with preferential trabecular alignment parallel to the long-axis of the bone, and nutrient foramina that pierce the bone at low angles of entry—that likely would have served as important adaptations to terrestrial weight support. A consilience of the three lines of evidence reported here strongly suggest that Ossinodus spent a significant part of its life on land, which is augmented by its exceptional degree of ossification, presaging the condition observed in later amniotes. Concluding that Ossinodus was at least partly adapted to a terrestrial lifestyle then, the skeletal morphology shown by Ossinodus may be used as a basis for interpreting the lifestyle of other stem tetrapods. For instance, comparison of the gross osteology of known elements for Ossinodus and Tulerpeton [15], as well as Pederpes [22], suggests that these stem tetrapods may too have been at least partly terrestrially adapted, although this remains to be further tested.
Ossinodus is the oldest biomechanically demonstrable, terrestrially adapted tetrapod, being at least two million years older than Casineria kiddi [10], and at least five million years older than the East Kirkton tetrapod assemblage [9]. These small (generally less than 40 cm long), Scottish tetrapods have previously been widely regarded as the oldest known terrestriality adapted vertebrates [1,9,10]. Moreover, the large size of certain recovered fossil bones of Ossinodus, such as the skull table, cleithrum and interclavicle [14], when scaled according to its likely body proportions [41] suggests that some Ossinodus individuals may have reached over 2 m in length. (That is, the radius which formed the basis for the current study quite probably belonged to an individual which was not fully grown.) The finding that large, terrestrially adapted tetrapods were already present in Gondwana by the mid-Viséan raises the possibility that the first terrestrial vertebrates were not small European forms, but large animals from Gondwana. This in turn necessitates a revision of our current understanding of the physiological and biogeographical context in which terrestriality in vertebrates evolved.
Acknowledgments
We thank K.K.W. Siu and Monash Biomedical Imaging for assistance with performing the CT scanning, and A.A. Warren, A.G. Cook, R. Ptasznik, and Y. Gouda for discussion. We greatly appreciate the constructive comments of two anonymous reviewers, and the editor, which helped improve the clarity and content of the manuscript. The staff of the Queensland Museum is thanked for assistance with access to the collection and literature. Specimen QMF 37451 and a copy of the CT scan data are held in the Geosciences Collection of the Queensland Museum, Brisbane, Australia.
Data Availability
Specimen QMF 37451 and a copy of the CT scan data are held in the Geosciences Collection of the Queensland Museum, Brisbane, Australia. These data will be made freely available to all qualified researchers upon a request being made to the Collections Manager.
Funding Statement
MJP is supported by a QUT research grant, CRM by an ARC grant (DR0986471) and a Monash University research grant, and CAB by an ARC QEII Fellowship DP110101127, a Human Frontiers Research Program (LT000130/2009-L), and an ARC Discovery Project DP 1096002. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
References
- 1. Clack JA. Gaining Ground: The Origin and Evolution of Tetrapods. 2nd ed Bloomington: Indiana University Press; 2012. [Google Scholar]
- 2. Shubin NH, Daeschler EB, Coates MI. The early evolution of the tetrapod humerus. Science 2004; 304: 90–93. [DOI] [PubMed] [Google Scholar]
- 3. Boisvert CA. The pelvic fin and girdle of Panderichthys and the origin of tetrapod locomotion. Nature 2005; 438: 1145–1147. [DOI] [PubMed] [Google Scholar]
- 4. Daeschler EB, Shubin NH, Jenkins FA Jr. A Devonian tetrapod-like fish and the evolution of the tetrapod body plan. Nature 2006; 440: 757–763. [DOI] [PubMed] [Google Scholar]
- 5. Shubin NH, Daeschler EB, Jenkins FA Jr. The pectoral fin of Tiktaalik roseae and the origin of the tetrapod limb. Nature 2006; 440: 764–771. [DOI] [PubMed] [Google Scholar]
- 6. Ahlberg PE, Clack JA, Lukševičs E, Blom H, Zupiņš I. Ventastega curonica and the origin of tetrapod morphology. Nature 2008; 453: 1199–1204. 10.1038/nature06991 [DOI] [PubMed] [Google Scholar]
- 7. Boisvert CA, Mark-Kurik E, Ahlberg PE. The pectoral fin of Panderichthys and the origin of digits. Nature 2008; 456: 636–638. 10.1038/nature07339 [DOI] [PubMed] [Google Scholar]
- 8. Ahlberg PE. Humeral homology and the origin of the tetrapod elbow: a reinterpretation of the enigmatic specimens ANSP 21350 and GSM 104536. Spec Pap Palaeontol 2011; 86: 17–29. [Google Scholar]
- 9. Rolfe WDI, Clarkson ENK, Panchen AL, eds. Volcanism and Early Terrestrial Biotas. Trans R Soc Edinburgh Earth Sci 1994; 84: 175–464. [Google Scholar]
- 10. Paton RL, Smithson TR, Clack JA. An amniote-like skeleton from the Early Carboniferous of Scotland. Nature 1999; 398: 508–513. [Google Scholar]
- 11. Coates MI, Clack JA. Romer’s gap: tetrapod origins and terrestriality. Bull Mus Natl Hist Nat, Paris 1995; 17C: 359–372. [Google Scholar]
- 12. Smithson TR, Wood SP, Marshall JEA, Clack JA. Earliest Carboniferous tetrapod and arthropod faunas from Scotland populate Romer’s Gap. Proc Natl Acad Sci USA 2012; 109: 4532–4537. 10.1073/pnas.1117332109 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. Thulborn T, Warren AA, Turner S, Hamley T. Early Carboniferous tetrapods in Australia. Nature 1996; 381: 777–780. [Google Scholar]
- 14. Warren AA, Turner S. The first stem tetrapod from the Lower Carboniferous of Gondwana. Palaeontology 2004; 47: 151–184. [Google Scholar]
- 15. Lebedev OA, Coates MI. The postcranial skeleton of the Devonian tetrapod Tulerpeton curtum Lebedev. Zool J Linn Soc 1995; 114: 307–348. [Google Scholar]
- 16. Bishop PJ. The humerus of Ossinodus pueri, a stem tetrapod from the Carboniferous of Gondwana, and the early evolution of the tetrapod forelimb. Alcheringa 2014; 38: 209–238. [Google Scholar]
- 17. Warren AA, Ptasznik R. The earliest fractured tetrapod bone. Alcheringa 2002; 26: 459–463. [Google Scholar]
- 18. Rothschild BM, Martin LD. Skeletal Impact of Disease. New Mexico Mus Natl Hist Sci Bull 2006; 33: 1–226. [Google Scholar]
- 19. Rayfield EJ. Finite element analysis and understanding the biomechanics and evolution of living and fossil organisms. Ann Rev Earth Planet Sci 2007; 35: 541–576. [Google Scholar]
- 20. Tsafnat N, Wroe S. An experimentally validated micromechanical model of a rat vertebra under compressive loading. J Anat 2011; 218: 40–46. 10.1111/j.1469-7580.2010.01289.x [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21. Ketcham RA, Ryan TM. Quantification and visualization of anisotropy in trabecular bone. J Microsc 2004; 213: 158–171. [DOI] [PubMed] [Google Scholar]
- 22. Clack JA, Finney SM. Pederpes finneyae, an articulated tetrapod from the Tournaisian of Scotland. J Syst Palaeontol 2005; 2: 311–346. [Google Scholar]
- 23. Milner AC, Lindsay W. Postcranial remains of Baphetes and their bearing on the relationships of the Baphetidae (= Loxommatidae). Zool J Linn Soc 1998; 122: 211–235. [Google Scholar]
- 24.International Commission on Radiological Protection. Report on the Task Group on Reference Man. ICRP Publication. 1975; No. 23. 480 p.
- 25. Currey JD. Bones: Structure and Mechanics. Princeton: Princeton University Press; 2002. [Google Scholar]
- 26. Erickson GM, Catanese J, Keaveny TM. Evolution of the biomechanical properties of the femur. Anat Rec 2002; 268: 115–124. [DOI] [PubMed] [Google Scholar]
- 27. Vogel S. Comparative Biomechanics: Life’s Physical World. Princeton: Princeton University Press; 2003. [Google Scholar]
- 28. McHenry CR, Wroe S, Clausen PD, Moreno K, Cunningham E. Supermodeled Sabercat, predatory behaviour in Smilodon fatalis revealed by high resolution 3D computer simulation. Proc Natl Acad Sci USA 2007; 104: 16010–16015. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29. Wirtz DC, Schiffers N, Pandorf T, Radermacher K, Weichert D, Forst R. Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur. J Biomech 2000; 33, 1325–1330. [DOI] [PubMed] [Google Scholar]
- 30. Dumont ER, Piccirillo J, Grosse IR. Finite-Element Analysis of Biting Behaviour and Bone Stress in the Facial Skeletons of Bats. Anat Rec 2005; 283A: 319–330. [DOI] [PubMed] [Google Scholar]
- 31. Biewener AA, Taylor CR; Bone strain: A determinant of gait and speed? J Exp Biol 1986; 123: 383–400. [DOI] [PubMed] [Google Scholar]
- 32. Anderson EM. The Dynamics of Faulting. 2nd ed Edinburgh: Oliver & Boyd; 1951. [Google Scholar]
- 33. Mason ML. Some observations on fractures of the head of the radius with a review of one hundred cases. Brit J Surg 1954; 42: 123–132. [DOI] [PubMed] [Google Scholar]
- 34. Amis AA, Miller JH. The mechanisms of elbow fractures: an investigation using impact tests in vitro . Injury 1995; 26: 163–168. [DOI] [PubMed] [Google Scholar]
- 35. Hanna RR. Multiple injury and infection in a sub-adult theropod dinosaur Allosaurus fragilis with comparisons to allosaur pathology in the Cleveland-Lloyd Dinosaur Quarry collection. J Vertebr Paleontol 2002; 22: 76–90. [Google Scholar]
- 36. Huiskes R, Ruimerman R, van Lenthe GH, Janssen, JD. Effects of mechanical forces on maintenance and adaptation of form in trabecular bone. Nature 2000; 405: 704–706. [DOI] [PubMed] [Google Scholar]
- 37. Ruimerman R, Hilbers P, van Rietbergen B, Huiskes R. A theoretical framework for strain-related trabecular bone maintenance and adaptation. J Biomech 2005; 38: 931–941. [DOI] [PubMed] [Google Scholar]
- 38. Tsubota K, Suzuki Y, Yamada T, Hojo M, Makinouchi A, Adachi T. Computer simulation of trabecular remodelling in human proximal femur using large-scale voxel FE models: Approach to understanding Wolff’s law. J Biomech 2009; 42: 1088–1094. 10.1016/j.jbiomech.2009.02.030 [DOI] [PubMed] [Google Scholar]
- 39. Wang H, Ji B, Liu XS, Guo XE, Huang Y, Hwang K-C. Analysis of microstructural and mechanical alterations of trabecular bone in a simulated three-dimensional remodelling process. J Biomech 2012; 45: 2417–2425 10.1016/j.jbiomech.2012.06.024 [DOI] [PubMed] [Google Scholar]
- 40. Walmsley CW, McCurry MR, Clausen PD, McHenry CR. Beware the black box: investigating the sensitivity of FEA simulations to modelling factors in comparative biomechanics. PeerJ 2013; 1: e204 10.7717/peerj.204 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41. Warren AA. New data on Ossinodus pueri, a stem tetrapod from the Early Carboniferous of Australia. J Vertebr Paleontol 2007; 27: 850–862. [Google Scholar]
- 42. Wang X, Zhang K, Wang Z, Ding Y, Wu W, Huang S. The decline of the Chinese giant salamander Andrias davidianus and implications for its conservation. Oryx 2004; 38: 197–202. [Google Scholar]
- 43. Donoghue OA, Shimojo H, Tagaki H. Impact forces of plyometric exercises performed on land and in water. Sports Health 2011; 3: 303–309. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Specimen QMF 37451 and a copy of the CT scan data are held in the Geosciences Collection of the Queensland Museum, Brisbane, Australia. These data will be made freely available to all qualified researchers upon a request being made to the Collections Manager.