Abstract
Cardiogenic shock (CS) is a life-threatening condition associated with significant morbidity and mortality. Pharmacological therapy is often the first line of treatment but mechanical support can provide substantial hemodynamic improvement in refractory CS. Percutaneous mechanical support devices are placed in a minimally invasive manner and provide life-saving assistance to the failing myocardium. We review the percutaneous devices currently available, the evidence behind their use, and the new advances in percutaneous technology being evaluated for the treatment of CS.
Keywords: cardiogenic shock, percutaneous mechanical support, heart-assist device
Introduction
Cardiogenic shock (CS) is a serious complication of acute myocardial infarction, with the mortality rate being as high as 50%.1 CS is defined by systemic hypoperfusion with systolic blood pressure <80 mmHg in the setting of marked decrease in cardiac index (<1.8 L/mm/m2) with elevated left ventricular filling pressures (pulmonary wedge pressure >18 mmHg).2 The low output state during CS can lead to multiorgan failure, which is associated with significant morbidity and mortality.
The pathophysiology of CS relates primarily to left ventricular pump failure, which results in decreased systemic and coronary perfusion.3 Systemic hypoperfusion results in catecholamine release and activation of systemic inflammatory and coagulation cascades.4 The interplay of these mechanisms then leads to further myocardial ischemia and dysfunction. Although pharmacologic agents such as inotropes and vaso-constrictors are the initial treatment modalities to improve perfusion, they do not break this vicious cycle.1 Mechanical circulatory support can interrupt this downward spiral by improving hemodynamics and providing time for myocardial recovery.4 Percutaneous mechanical support can augment cardiac output and therefore serve as a bridge to recovery. The goal of this review is to provide an overview of the percutaneous mechanical support devices currently available for patients with CS.
Intra-Aortic Balloon Pump (IABP)
IABPs were first introduced in humans in the 1960s and are the most commonly used form of mechanical hemodynamic support in CS.5,6 The balloon is advanced from the common femoral artery into the aorta, with the proximal tip placed before the left subclavian artery (Fig. 1).7 Inflation of the balloon occurs in diastole, augmenting diastolic pressure to increase coronary blood flow. Deflation occurs in systole, decreasing afterload and promoting left ventricular blood outflow. The net effect is decreased myocardial oxygen consumption, increased cardiac output, and lower peak left ventricular wall stress.8 The hemodynamic benefit with IABP is increased cardiac output of 0.5–1 L/min.9 Major complications associated with IABP are low (0.5%), and include limp, bowel, and renal ischemia.7 The mortality rate with IABP is less than 0.05%.10 IABP should be used cautiously in peripheral arterial disease and is contraindicated in patients with severe aortic regurgitation and aortic dissection.7
Figure 1.
Illustration of intra-aortic balloon pump located distal to left subclavian artery (Pictorial reprinted with permission from artist Ridha Gilani).
However, there is conflicting evidence regarding the benefit of IABP in CS, and randomized trials have been difficult to perform in this patient population.11 The data from the Should We Emergently Revascularize Occluded Coronaries for Cardiogenic Shock (SHOCK) Trial Registry demonstrated lower in-hospital mortality for patients with CS after myocardial infarction if treated with IABP.12 Results from the cohort study Global Utilization of Streptokinase and TPA for Occluded Coronary Arteries (GUSTO-1) showed that early use of IABP had lower mortality at 30 days and 1 year.13 More recently, the Intra-aortic Balloon Support for Myocardial Infarction with Cardiogenic Shock (IABP-SHOCK II) trial evaluated 600 patients in CS after myocardial infarction, and randomized them to IABP versus no IABP.14 This study found no significant difference in all-cause mortality between the two groups at 30 days. Therefore, the 2013 American College of Cardiology/American Heart Association (ACC/AHA) STEMI and European Society of Cardiology (ESC) STEMI guidelines give IABP therapy in CS class IIa and IIb recommendations, respectively.11,15
Percutaneous Left Ventricular Assist Devices – Impella® and Tandem Heart®
The Impella (Abiomed Inc.) is an axial flow pump on a pigtail catheter that crosses the aortic valve to unload the left ventricle by delivering nonpulsatile blood flow to the ascending aorta (Fig. 2).16 Currently, there are three Impella systems available for femoral introduction. The larger Impella 5.0 system provides up to 5 L/min and requires femoral cutdown for placement due its 21 Fr motor pump.17 The Impella 2.5 device is introduced from a femoral percutaneous approach and can deliver an output of 2.5 L/min through a 12 Fr motor pump. The Impella CP uses the same delivery platform as the Impella 2.5 but is able to provide 4 L/min through a 14 Fr motor pump.
Figure 2.

The Impella with the inflow area in the left ventricle and the outflow area in the ascending aorta (Reprinted with permission from Abiomed).
The contraindications to the placement of the device include moderate aortic stenosis or insufficiency, ventricular septal defect, left ventricular thrombus, and significant peripheral vascular disease.18 Although aortic stenosis is considered an exclusion criterion in clinical trials with Impella, a small series showed that implantation was feasible in patients with severe AS and left ventricular impairment.19,20 A balloon-assist technique can be used to facilitate device implantation if unassisted attempts fail.20 The most commonly reported complications of Impella placement include limb ischemia, vascular injury, and bleeding requiring blood transfusion.21 Hemolysis has been reported in 5%–10% of patients during the first 24 hours.22 Proper positioning of the inlet cannula reduces risk of hemolysis and aortic valve injury.4 One small study evaluated the safety profile of Impella in comparison to IABP and found similar vascular and bleeding risk, with blood transfusions occurring in 38.4% and 32.2% of patients in the Impella and IABP groups, respectively.23
The hemodynamic benefits of Impella have been evaluated in small, randomized controlled trials and observational studies. The Impella LP 2.5 versus IABP in Cardiogenic Shock (ISAR-SHOCK) trial randomized 26 patients with CS due to acute myocardial infarction to treatment with Impella or IABP.24 The Impella resulted in greater increase in cardiac index (CI) at 30 minutes when compared to IABP (Impella CI 1.71 L/min/m2 at baseline to 2.20 L/min/m2 at 30 minutes vs IABP CI 1.73 L/min/m2 at baseline to 1.81 L/min/m2) but this difference was not statistically significant and there was absolutely no difference in mortality rates at 30 days. A retrospective review by Lemaire et al evaluated the use of Impella in 47 patients, where the indication for placement included cardiogenic shock in 15 and postcardiotomy cardiogenic shock in 32. Successful Impella wean and ventricular function recovery occurred in 72% of patients.25 The 30-day mortality in this high-risk population was 25%, which is significantly lower than the 50% morality often seen in patients with cardiogenic shock.1,25 The USella Registry compared the outcomes of CS in acute myocardial infarction patients supported with Impella 2.5 before percutaneous coronary intervention (pre-PCI) versus those that received the device after percutaneous coronary intervention (post-PCI). The study found better survival to discharge in the pre-PCI group in the setting of refractory CS (65.1% vs 40.7%, P = 0.003).26 A recent meta-analysis involving 2,843 patients from 13 trials compared the safety and efficacy of IABP, percutaneous left ventricular assist device (LVAD), and medical therapy (MT) in patients undergoing high-risk PCI. Mechanical hemodynamic support showed no survival benefit over medical therapy even in cardiogenic shock (IABP vs MT, P = 0.230; LVAD vs MT; P = 0.535), but was associated with an increase in moderate to severe bleeding.27
Impella technology is becoming increasingly important in the management of CS because it improves hemodynamics.28 The Impella CP combines the added benefit of percutaneous deliverability and higher cardiac output. Although no direct hemodynamic comparison has been described between the Impella CP and 2.5 L, a recent case series showed that the Impella CP device was safe with low incidence of vascular complications.29 Further prospective randomized and adequately powered studies are necessary to evaluate the usefulness of Impella CP in CS refractory to pharmacotheraphy.
The TandemHeart® device (CardiacAssist Inc.) is an external centrifugal pump, with a 21 Fr inflow cannula placed transeptally into the left atrium and an outflow cannula placed into the femoral artery (Fig. 3).28 Oxygenated blood is pumped into the femoral artery and can provide 3.5–4.5 L/min of cardiac output.4 The insertion time on average can exceed 30 minutes in nonemergent situations.30
Figure 3.
TandemHeart external centrifugal pump placed transeptally into the left atrium and the outflow cannula placed into the femoral artery (Reprinted with permission from CardiacAssist).
The requirement of transeptal puncture increases the risks and complexity of device placement. The complications associated with device placement include tamponade, major bleeding, aortic insufficiency, critical limb ischemia, arrhythmias, and residual atrial septal defect, which can later require closure.18 One case series found that access site bleeding occurred in 25% of patients.31 Contraindications include aortic insufficiency, ventricular septal defect, and significant peripheral artery disease.18 It can be particularly useful in cases of CS complicated by significant aortic stenosis.
Two randomized, controlled trials and a retrospective analysis have evaluated the efficacy of TandemHeart in CS. The first study randomized 41 patients with acute myocardial infarction presenting with CS to IABP or TandemHeart and showed higher cardiac index but no mortality benefit at 30 days (43% TandemHeart vs 45% IABP).32 Complications such as severe bleeding (n = 19 vs n = 8, P = 0.002) and limb ischemia (n = 7 vs n = 0, P = 0.009) were encountered more frequently with TandemHeart. A second study randomized 30 patients presenting with CS and found similar hemodynamic improvement with TandemHeart when compared to IABP but no improvement in survival at 30 days.33 A larger retrospective study analyzed 117 patients with CS refractory to IABP and vasopressor support treated with TandemHeart.34 Hemodynamic improvement after implantation included an increase in cardiac index (0.52 to 3.0 L/min/m2), systolic blood pressure, mixed venous oxygen saturation, and urine output. A decrease was seen in pulmonary capillary wedge pressure, lactic acid level, and creatinine. The mortality rate at 30 days was 40.2%.
Despite the hemodynamic improvement seen with Impella and TandemHeart in comparison to IABP, no study has shown a survival benefit. Therefore, the 2013 ACC/AHA STEMI guidelines give class IIb recommendation for alternative left ventricular assist devices for circulatory support in patients refractory CS.15
Extracorporeal Membrane Oxygenation (ECMO)
ECMO was first used in adults in 1972, and is able to serve the function of both the heart and lungs.35 Deoxygenated blood taken out of the body through a drainage cannula is passed through an oxygenator and returned to the systemic circulation.36 The oxygenator is a gas exchange device that directly oxygenates and removes carbon dioxide from the blood. Blood flow is generated by a centrifugal pump, where a rotating impeller spins blood outwards at high flow rates with minimal trauma to blood components.7 When combined with an oxygenator, the TandemHeart can also serve as the external centrifugal pump for ECMO (Fig. 4). If blood is removed from a central vein and returned into the venous system, the process is referred to as veno-venous ECMO (VV-ECMO).37 When blood is drained from the venous system and returned into the arterial system, the process is known as veno-arterial ECMO (VA-ECMO).37 VV-ECMO provides respiratory support, while VA-ECMO is used for cardiorespiratory support, including CS. Complications associated with VA-ECMO include severe bleeding, hemorrhagic stroke, embolic phenomenon, nosocomial infections, and multiorgan dysfunction.38,39 Advances in extracorporeal technology, including the advent of new pumps and oxygenators, have decreased these risks significantly.40
Figure 4.
TandemHeart device in VA-ECMO (left) and VV-ECMO configuration (right) (Reprinted with permission from CardiacAssist).
The benefit of ECMO in CS patients has been evaluated in small nonrandomized studies. The survival rate associated with ECMO in these studies ranged from 31%–64%.38,41–43 The Extracorporeal Life Support Organization (ELSO) registry data collected from 223 ECMO centers reported 4,042 adults treated for CS, with a survival rate of 40% at discharge.44 One cohort study from a single institution prospectively compared the outcomes of Impella and TandemHeart versus ECMO for postinfarction or decompensated cardiomyopathy-related CS.45 No difference was seen between the two groups with respect to hospital mortality, wean from mechanical support, bridge to long-term destination therapy and transplant, or limb complications.
The timing of when to initiate ECMO is controversial, as there are no consensus recommendations from the ACC/AHA.7,15 ESC STEMI guidelines note that ECMO can be used in CS as destination therapy or a bridge to transplant, but the evidence for benefit is limited.11 Randomized, controlled trials are ultimately necessary to determine the true benefit of ECMO in CS.46
Advancement in Percutaneous Ventricular Assist Devices
Newer percutaneous ventricular assist devices are in development for CS with the goal to provide hemodynamic support while simultaneously limiting complications by using smaller delivery systems. Thoratec Corporation’s HeartMate PHP™ is a catheter-based axial flow pump that can provide up to 5 L/min.47 Inserted percutaneously through the femoral artery, the 12 Fr catheter contains a distal collapsible, covered nitinol cannula with an impeller that expands to 24 Fr. A clinical trial for the evaluation of the HeartMate PHP in CS is currently under way. The Reitan Catheter Pump (RCP) is another transcatheter pump undergoing evaluation for CS. The RCP is a 14 Fr collapsible propeller inside a protective cage that is positioned in the descending part of the thoracic aorta via the femoral artery.48 An initial small, prospective, nonrandomized study of 14 patients showed 30% improvement in cardiac index at 24 hours (1.85 to 2.45 L/min/m2; P = 0.08), 22% reduction in serum creatinine at 24 hours (174 to 142 umol/L P = 0.0002), and an increase in glomerular filtration rate (GFR) from 50.2 to 61 mL/min (P = 0.001).48 The Impella RP (Right Percutaneous) System (Abiomed Inc.) is a percutaneous microaxial pump that is being evaluated for right ventricular failure.49 It aspirates blood from the inferior vena cava and expels it into the pulmonary artery at the maximum rate of up to 4.4 L/min. It may serve as a percutaneous hemodynamic support option in CS secondary to right ventricular failure.
Conclusions
Although percutaneous mechanical support devices used in CS can improve hemodynamics, studies have not shown clear mortality benefit. However, it is obvious that there are numerous logistic and ethical challenges in performing a large randomized study in CS patients, such as appropriate patient selection, device selection, timing of initial support initiation, and cost effectiveness.4 Randomized, controlled trials comparing the various percutaneous devices currently available may shed light on appropriate patient and device selection, and further advances in technology may also lead to improved outcomes in this sick patient population.
Acknowledgments
We wish to thank D Gershon Lewental for comments that greatly improved the manuscript.
Footnotes
ACADEMIC EDITOR: Thomas E. Vanhecke, Editor in Chief
FUNDING: Authors disclose no funding sources.
COMPETING INTERESTS: Authors disclose no potential conflicts of interest.
Paper subject to independent expert blind peer review by minimum of two reviewers. All editorial decisions made by independent academic editor. Upon submission manuscript was subject to anti-plagiarism scanning. Prior to publication all authors have given signed confirmation of agreement to article publication and compliance with all applicable ethical and legal requirements, including the accuracy of author and contributor information, disclosure of competing interests and funding sources, compliance with ethical requirements relating to human and animal study participants, and compliance with any copyright requirements of third parties. This journal is a member of the Committee on Publication Ethics (COPE).
Author Contributions
Conceived and designed the review article, wrote the first draft of the manuscript: FSG. Jointly developed the structure and arguments for the paper: FSG, LG. Contributed to writing: FSG, SF, RD, LG. Agreed with manuscript results and conclusions: FSG, LG. All authors read and approved the final version.
REFERENCES
- 1.Babaev A, Frederick PD, Pasta DJ, Every N, Sichrovsky T, Hochman JS. Trends in management and outcomes of patients with acute myocardial infarction complicated by cardiogenic shock. JAMA. 2005;294(4):448–54. doi: 10.1001/jama.294.4.448. [DOI] [PubMed] [Google Scholar]
- 2.Mann D, Zipes D, Libby P, Bonow R. Braunwald’s Heart Disease: A Textbook of Cardiovascular Medicine. 10th ed. Vol. 2. Mosby: US Elsevier Health Bookshop; 2012. [Google Scholar]
- 3.Reynolds HR, Hochman JS. Cardiogenic shock: current concepts and improving outcomes. Circulation. 2008;117(5):686–97. doi: 10.1161/CIRCULATIONAHA.106.613596. [DOI] [PubMed] [Google Scholar]
- 4.Kar B, Basra SS, Shah NR, Loyalka P. Percutaneous circulatory support in cardiogenic shock: interventional bridge to recovery. Circulation. 2012;125(14):1809–17. doi: 10.1161/CIRCULATIONAHA.111.040220. [DOI] [PubMed] [Google Scholar]
- 5.Thiele H, Allam B, Chatellier G, Schuler G, Lafont A. Shock in acute myocardial infarction: the Cape Horn for trials? Eur Heart J. 2010;31(15):1828–35. doi: 10.1093/eurheartj/ehq220. [DOI] [PubMed] [Google Scholar]
- 6.Kantrowitz A. Initial clinical experience with intraaortic balloon pumping in cardiogenic shock. JAMA. 1968;203(2):113. [PubMed] [Google Scholar]
- 7.Cove ME, MacLaren G. Clinical review: mechanical circulatory support for cardiogenic shock complicating acute myocardial infarction. Crit Care. 2010;14(5):235. doi: 10.1186/cc9229. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Kern M. Coronary artery disease. Coron Artery Dis. 1991;2:649–60. [Google Scholar]
- 9.Gabauer I, Nosál’ová V, Okolicány J, Trnovec T, Styk J, Holec V. Distribution of cardiac output following 2 hours of intra-aortic balloon counterpulsation. Bratisl Lek Listy. 1980;73(1):26–35. [PubMed] [Google Scholar]
- 10.Stone GW, Ohman EM, Miller MF, et al. Contemporary utilization and outcomes of intra-aortic balloon counterpulsation in acute myocardial infarction: the benchmark registry. J Am Coll Cardiol. 2003;41(11):1940–5. doi: 10.1016/s0735-1097(03)00400-5. [DOI] [PubMed] [Google Scholar]
- 11.Steg PG, James SK, Atar D, et al. ESC Guidelines for the management of acute myocardial infarction in patients presenting with ST-segment elevation. Eur Heart J. 2012;33(20):2569–619. doi: 10.1093/eurheartj/ehs215. [DOI] [PubMed] [Google Scholar]
- 12.Hochman JS, Sleeper LA, Godfrey E, et al. Should we emergently revascularize occluded coronaries for cardiogenic shocK: an international randomized trial of emergency PTCA/CABG-trial design. The SHOCK Trial Study Group. Am Heart J. 1999;137(2):313–21. doi: 10.1053/hj.1999.v137.95352. [DOI] [PubMed] [Google Scholar]
- 13.Anderson RD, Ohman EM, Holmes DR, Jr, et al. Use of intraaortic balloon counterpulsation in patients presenting with cardiogenic shock: observations from the GUSTO-I Study. J Am Coll Cardiol. 1997;30(3):708–15. doi: 10.1016/s0735-1097(97)00227-1. [DOI] [PubMed] [Google Scholar]
- 14.Thiele H, Zeymer U, Neumann F-J, et al. IABP-SHOCK II Trial Investigators. Intraaortic balloon support for myocardial infarction with cardiogenic shock. N Engl J Med. 2012;367(14):1287–96. doi: 10.1056/NEJMoa1208410. [DOI] [PubMed] [Google Scholar]
- 15.O’Gara PT, Kushner FG, Ascheim DD, et al. American College of Cardiology Foundation. American Heart Association Task Force on Practice Guidelines. American College of Emergency Physicians. Society for Cardiovascular Angiography and Interventions 2013 ACCF/AHA guideline for the management of ST-elevation myocardial infarction: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol. 2013;61(4):e78–140. doi: 10.1016/j.jacc.2012.11.019. [DOI] [PubMed] [Google Scholar]
- 16.Valgimigli M, Steendijk P, Sianos G, Onderwater E, Serruys PW. Left ventricular unloading and concomitant total cardiac output increase by the use of percutaneous Impella Recover LP 2.5 assist device during high-risk coronary intervention. Catheter Cardiovasc Interv. 2005;65(2):263–7. doi: 10.1002/ccd.20380. [DOI] [PubMed] [Google Scholar]
- 17.Siegenthaler MP, Brehm K, Strecker T, et al. The Impella recover microaxial left ventricular assist device reduces mortality for postcardiotomy failure: a three-center experience. J Thorac Cardiovasc Surg. 2004;127(3):812–22. doi: 10.1016/j.jtcvs.2003.09.055. [DOI] [PubMed] [Google Scholar]
- 18.Naidu SS. Novel percutaneous cardiac assist devices: the science of and indications for hemodynamic support. Circulation. 2011;123(5):533–43. doi: 10.1161/CIRCULATIONAHA.110.945055. [DOI] [PubMed] [Google Scholar]
- 19.Badawi RA, Grise MA, Thornton SN. Impella 2.5 assisted balloon aortic valvuloplasty and percutaneous coronary intervention as a bridge to heart transplantation. J Invasive Cardiol. 2012;24(5):229–30. [PubMed] [Google Scholar]
- 20.Spiro J, Venugopal V, Raja Y, Ludman PF, Townend JN, Doshi SN. Feasibility and efficacy of the 2.5 L and 3.8 L Impella percutaneous left ventricular support device during high-risk, percutaneous coronary intervention in patients with severe aortic stenosis. Catheter Cardiovasc Interv. 2014;85(6):981–9. doi: 10.1002/ccd.25355. [DOI] [PubMed] [Google Scholar]
- 21.Remmelink M, Sjauw KD, Henriques JP, et al. Effects of left ventricular unloading by Impella recover LP2.5 on coronary hemodynamics. Catheter Cardiovasc Interv. 2007;70(4):532–7. doi: 10.1002/ccd.21160. [DOI] [PubMed] [Google Scholar]
- 22.Dixon SR, Henriques JP, Mauri L, et al. A prospective feasibility trial investigating the use of the Impella 2.5 system in patients undergoing high-risk percutaneous coronary intervention (The PROTECT I Trial): initial U.S. experience. JACC Cardiovasc Interv. 2009;2(2):91–6. doi: 10.1016/j.jcin.2008.11.005. [DOI] [PubMed] [Google Scholar]
- 23.Boudoulas KD, Pederzolli A, Saini U, et al. Comparison of Impella and intra-aortic balloon pump in high-risk percutaneous coronary intervention: vascular complications and incidence of bleeding. Acute Card Care. 2012;14(4):120–4. doi: 10.3109/17482941.2012.741244. [DOI] [PubMed] [Google Scholar]
- 24.Seyfarth M, Sibbing D, Bauer I, et al. A randomized clinical trial to evaluate the safety and efficacy of a percutaneous left ventricular assist device versus intra-aortic balloon pumping for treatment of cardiogenic shock caused by myocardial infarction. J Am Coll Cardiol. 2008;52(19):1584–8. doi: 10.1016/j.jacc.2008.05.065. [DOI] [PubMed] [Google Scholar]
- 25.Lemaire A, Anderson MB, Lee LY, et al. The Impella device for acute mechanical circulatory support in patients in cardiogenic shock. Ann Thorac Surg. 2014;97(1):133–8. doi: 10.1016/j.athoracsur.2013.07.053. [DOI] [PubMed] [Google Scholar]
- 26.O’Neill WW, Schreiber T, Wohns DH, et al. The current use of Impella 2.5 in acute myocardial infarction complicated by cardiogenic shock: results from the USpella Registry. J Interv Cardiol. 2014;27(1):1–11. doi: 10.1111/joic.12080. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Lee JM, Park J, Kang J, et al. TCT-65 the efficacy and safety of mechanical hemodynamic support in patients undergoing high-risk percutaneous coronary intervention with or without cardiogenic shock: Bayesian approach network meta-analysis of 13 randomized controlled trials. J Am Coll Cardiol. 2014;64(11):B19. doi: 10.1016/j.ijcard.2015.01.081. [DOI] [PubMed] [Google Scholar]
- 28.Acharya D, Loyaga-Rendon RY, Tallaj JA, Pamboukian SV, Sasse MF. Circulatory support for shock complicating myocardial infarction. J Invasive Cardiol. 2014;26(8):E109–14. [PubMed] [Google Scholar]
- 29.Venugopal V, Spiro J, Zaphiriou A, et al. Percutaneous mechanical ventricular support in acute cardiac care: a UK quaternary centre experience using 2.5 L, 3.8 L and 5.0 L Impella Catheters. Cardiol Ther. 2014 doi: 10.1007/s40119-014-0033-8. [Epub ahead of print] [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Al-Husami W, Yturralde F, Mohanty G, et al. Single-center experience with the TandemHeart percutaneous ventricular assist device to support patients undergoing high-risk percutaneous coronary intervention. J Invasive Cardiol. 2008;20(6):319–22. [PubMed] [Google Scholar]
- 31.Vranckx P, Meliga E, De Jaegere PPT, Van den Ent M, Regar ES, Serruys PW. The TandemHeart, percutaneous transseptal left ventricular assist device: a safeguard in high-risk percutaneous coronary interventions. The six-year Rotterdam experience. EuroIntervention. 2008;4(3):331–7. doi: 10.4244/eijv4i3a60. [DOI] [PubMed] [Google Scholar]
- 32.Thiele H, Sick P, Boudriot E, et al. Randomized comparison of intra-aortic balloon support with a percutaneous left ventricular assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shock. Eur Heart J. 2005;26(13):1276–83. doi: 10.1093/eurheartj/ehi161. [DOI] [PubMed] [Google Scholar]
- 33.Burkhoff D, Cohen H, Brunckhorst C, O’Neill WW. A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock. Am Heart J. 2006;152(3):469.e1–8. doi: 10.1016/j.ahj.2006.05.031. [DOI] [PubMed] [Google Scholar]
- 34.Kar B, Gregoric ID, Basra SS, Idelchik GM, Loyalka P. The percutaneous ventricular assist device in severe refractory cardiogenic shock. J Am Coll Cardiol. 2011;57(6):688–96. doi: 10.1016/j.jacc.2010.08.613. [DOI] [PubMed] [Google Scholar]
- 35.Hill JD, O’Brien TG, Murray JJ, et al. Prolonged extracorporeal oxygenation for acute post-traumatic respiratory failure (shock-lung syndrome). Use of the Bramson membrane lung. N Engl J Med. 1972;286(12):629–34. doi: 10.1056/NEJM197203232861204. [DOI] [PubMed] [Google Scholar]
- 36.Gattinoni L, Carlesso E, Langer T. Clinical review: extracorporeal membrane oxygenation. Crit Care. 2011;15(6):243. doi: 10.1186/cc10490. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Lafç G, Budak AB, Yener AÜ. Cicek OF. Use of extracorporeal membrane oxygenation in adults. Heart Lung Circ. 2014;23(1):10–23. doi: 10.1016/j.hlc.2013.08.009. [DOI] [PubMed] [Google Scholar]
- 38.Combes A, Leprince P, Luyt CE, et al. Outcomes and long-term quality-of-life of patients supported by extracorporeal membrane oxygenation for refractory cardiogenic shock. Crit Care Med. 2008;36(5):1404–11. doi: 10.1097/CCM.0b013e31816f7cf7. [DOI] [PubMed] [Google Scholar]
- 39.Smedira NG, Moazami N, Golding CM, et al. Clinical experience with 202 adults receiving extracorporeal membrane oxygenation for cardiac failure: survival at five years. J Thorac Cardiovasc Surg. 2001;122(1):92–102. doi: 10.1067/mtc.2001.114351. [DOI] [PubMed] [Google Scholar]
- 40.Combes A, Bacchetta M, Brodie D, Müller T, Pellegrino V. Extracorporeal membrane oxygenation for respiratory failure in adults. Curr Opin Crit Care. 2012;18(1):99–104. doi: 10.1097/MCC.0b013e32834ef412. [DOI] [PubMed] [Google Scholar]
- 41.Jaski BE, Lingle RJ, Overlie P, et al. Long-term survival with use of percutaneous extracorporeal life support in patients presenting with acute myocardial infarction and cardiovascular collapse. ASAIO J. 1999;45(6):615–8. doi: 10.1097/00002480-199911000-00018. [DOI] [PubMed] [Google Scholar]
- 42.Kim H, Lim SH, Hong J, et al. Efficacy of veno-arterial extracorporeal membrane oxygenation in acute myocardial infarction with cardiogenic shock. Resuscitation. 2012;83(8):971–5. doi: 10.1016/j.resuscitation.2012.01.037. [DOI] [PubMed] [Google Scholar]
- 43.Bermudez CA, Rocha RV, Toyoda Y, et al. Extracorporeal membrane oxygenation for advanced refractory shock in acute and chronic cardiomyopathy. Ann Thorac Surg. 2011;92(6):2125–31. doi: 10.1016/j.athoracsur.2011.07.029. [DOI] [PubMed] [Google Scholar]
- 44.Paden ML, Conrad SA, Rycus PT, Thiagarajan RR. Extracorporeal life support organization registry report 2012. ASAIO J. 2013;59(3):202–10. doi: 10.1097/MAT.0b013e3182904a52. [DOI] [PubMed] [Google Scholar]
- 45.Chamogeorgakis T, Rafael A, Shafii AE, Nagpal D, Pokersnik JA, Gonzalez-Stawinski GV. Which is better: a miniaturized percutaneous ventricular assist device or extracorporeal membrane oxygenation for patients with cardiogenic shock? ASAIO J. 2013;59(6):607–11. doi: 10.1097/MAT.0b013e3182a8baf7. [DOI] [PubMed] [Google Scholar]
- 46.Abrams D, Combes A, Brodie D. Extracorporeal membrane oxygenation in cardiopulmonary disease in adults. J Am Coll Cardiol. 2014;63(25 pt A):2769–78. doi: 10.1016/j.jacc.2014.03.046. [DOI] [PubMed] [Google Scholar]
- 47.Kandzari D, Ebner A, Muller P. TCT-126 first-in-human experience with a novel high-flow percutaneous heart pump. J Am Coll Cardiol. 2013;62(18):B41. [Google Scholar]
- 48.Keeble T, Smith E, Ferrari M, et al. TCT-378 interim analysis of the reitan catheter pump (RCP) heart failure efficacy study: RCP improves cardiovascular and renal function in acute decompensated heart failure (ADHF) J Am Coll Cardiol. 2012;60(17):B108. [Google Scholar]
- 49.Cheung A, Freed D, Hunziker P, Leprince P. TCT-371 first clinical evaluation of a novel percutaneous right ventricular assist device: the Impella RP. J Am Coll Cardiol. 2012;60(17):B106–7. [Google Scholar]