Where Are We Now?
Total joint arthroplasty (TJA) infection causes severe morbidity that may result in mortality, and generates substantial costs both to the patient and the healthcare system. Early studies found that the use of negative-pressure body exhaust suits decreased the risk of deep infection following TJA [1, 4]. However, more-recent work has found an equal or higher infection rate with use of modern positive-pressure surgical helmet systems compared to conventional surgical gowns [2, 5]. It is not known why surgical helmet systems have not yielded similar decreases in infection rates as those reported with body exhaust suits. There are numerous challenges in answering this question among cases employing surgical helmet systems. These challenges include: (1) Conducting adequately powered studies of TJA infection, a rare event; and (2) using culture-positive TJA infection as a study endpoint as opposed to less-meaningful surrogates for infection.
Where Do We Need To Go?
This current study examines the gown-glove interface as a potential source of contamination with use of surgical helmet systems during TJA. It is theorized that positive pressure within the gown causes contaminated skin cells to escape through the unsealed gown-glove interface. Using 0.5 micron fluorescent powder as a surrogate for contaminated skin particles, the authors demonstrate that the gown-glove interface is a source of contamination in several types of surgical helmet systems equal to that of a conventional gown during simulated TJA. The study proposes that increased contamination at the gown-glove interface may occur with stiffer gowns, likely due to a further compromised gown-glove seal. While there may be sufficient evidence to propose a study examining a secure band placed at the glove cuff to seal the gown-glove interface, several unanswered questions remain. First, does contamination at the gown-glove interface result in TJA infection? Second, is there a difference in sterile technique surgeons employ with use of surgical helmet systems that may explain the higher infection rate observed in some studies as compared to traditional gowns? Third, do the findings of early studies demonstrating a lower infection rate with use of negative pressure body exhaust suits compared to traditional gowns hold true in the context of contemporary surgical protocols?
How Do We Get There?
In order to determine if contamination at the gown-glove interface results in TJA infection, an adequately powered, prospective randomized controlled trial evaluating TJA infection rate of surgeons wearing a surgical helmet system with and without a secure band at the glove cuff should be conducted. However, a pilot study in which culture swabs are obtained of the gown-glove interface at the conclusion of TJA performed with and without a secure band at the glove cuff may be more practical. Multiple studies have demonstrated that surgical helmet systems should not be considered sterile, and a glove change should be performed following contact with the surgical helmet systems [3, 6]. However, surgeons may not strictly adhere to this practice, which may explain the higher infection rates with surgical helmet systems observed in some studies. A study of this hypothesis may be performed by counting the number of contacts made with the surgical helmet system during TJA, which would not occur with use of a conventional gown. In studies conducted more than 30 years ago, use of body exhaust suits was found to decrease TJA infection rate. Since that time, factors with relevance to infection risk have changed, including emergence of resistant bacteria, increased obesity, advent of new immunosuppressive drugs, and shorter operative times. As a result, the presumed benefits of negative pressure body exhaust suits may be revisited in a registry study comparing TJA infection rate among surgeons wearing a modern, less cumbersome version of a body exhaust suits versus a conventional gown.
Footnotes
This CORR Insights® is a commentary on the article “The Gown-glove Interface Is a Source of Contamination: A Comparative Study” by Fraser and colleagues available at: DOI: 10.1007/s11999-014-4094-8.
The author certifies that he, or any member of his immediate family, has no funding or commercial associations (eg, consultancies, stock ownership, equity interest, patent/licensing arrangements, etc) that might pose a conflict of interest in connection with the submitted article.
All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research ® editors and board members are on file with the publication and can be viewed on request.
The opinions expressed are those of the writers, and do not reflect the opinion or policy of CORR ® or the Association of Bone and Joint Surgeons®.
This CORR Insights® comment refers to the article available at DOI: 10.1007/s11999-014-4094-8.
References
- 1.Blomgren G, Hambraeus A, Malmborg AS. The influence of the total body exhaust suit on air and wound contamination in elective hip-operations. J Hosp Infect. 1983;4:257–268. doi: 10.1016/0195-6701(83)90026-9. [DOI] [PubMed] [Google Scholar]
- 2.Hooper GJ, Rothwell AG, Frampton C, Wyatt MC. Does the use of laminar flow and space suits reduce early deep infection after total hip and knee replacement? The ten-year results of the New Zealand Joint Registry. J Bone Joint Surg Br. 2011;93:85–90. doi: 10.1302/0301-620X.93B1.24862. [DOI] [PubMed] [Google Scholar]
- 3.Kearns KA, Witmer D, Makda J, Parvizi J, Jungkind D. Sterility of the personal protection system in total joint arthroplasty. Clin Orthop Relat Res. 2011;469:3065–3069. doi: 10.1007/s11999-011-1883-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Lidwell OM, Lowbury EJ, Whyte W, Blowers R, Stanley SJ, Lowe D. Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomized study. Br Med J (Clin Res Ed). 1982;285:10–14. doi: 10.1136/bmj.285.6334.10. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Shaw JA, Bordner MA, Hamory BH. Efficacy of the Steri-Shield filtered exhaust helmet in limiting bacterial counts in the operating room during total joint arthroplasty. J Arthroplasty. 1996;11:469–473. doi: 10.1016/S0883-5403(96)80038-6. [DOI] [PubMed] [Google Scholar]
- 6.Singh VK, Hussain S, Javed S, Singh I, Mulla R, Kalairajah Y. Sterile surgical helmet system in elective total hip and knee arthroplasty. J Orthop Surg (Hong Kong). 2011;19:234–237. doi: 10.1177/230949901101900222. [DOI] [PubMed] [Google Scholar]