Use of dentomaxillofacial cone beam computed tomography in dentistry

Kıvanç Kamburoğlu 1
PMCID: PMC4473305  PMID: 26120381

Abstract

Cone-beam computed tomography (CBCT) was developed and introduced specifically for dento-maxillofacial imaging. CBCT possesses a number of advantages over medical CT in clinical practice, such as lower effective radiation doses, lower costs, fewer space requirements, easier image acquisition, and interactive display modes such as mutiplanar reconstruction that are applicable to maxillofacial imaging. However, the disadvantages of CBCT include higher doses than two-dimensional imaging; the inability to accurately represent the internal structure of soft tissues and soft-tissue lesions; a limited correlation with Hounsfield Units for standardized quantification of bone density; and the presence of various types of image artifacts, mainly those produced by metal restorations. CBCT is now commonly used for a variety of purposes in oral implantology, dento-maxillofacial surgery, image-guided surgical procedures, endodontics, periodontics and orthodontics. CBCT applications provide obvious benefits in the assessment of dentomaxillofacial region, however; it should be used only in correct indications considering the necessity and the potential hazards of the examination.

Keywords: Radiography, Dentistry, Dentomaxillofacial, Radiology, Cone-beam computed tomography


Core tip: Cone-beam computed tomography (CBCT) is now commonly used for a variety of purposes in oral implantology, dento-maxillofacial surgery, image-guided surgical procedures, endodontics, periodontics and orthodontics. CBCT applications provide obvious benefits in the assessment of dentomaxillofacial region, however; it should be used only in correct indications considering the necessity and the potential hazards of the examination.

CONE BEAM COMPUTED TOMOGRAPHY

Cone-beam computed tomography (CBCT) was developed and introduced specifically for dento-maxillofacial imaging[1]. A practical cone-beam algorithm for tomographic reconstruction of 2-D projection data was first illustrated by Feldkamp in 1984, who, used a back-projection formula to directly reconstruct a 3-D density function from a set of two-dimensional projections. CBCT units dedicated to dento-maxillofacial radiology could not be marketed for another 15 years because economic X-ray tubes, high-quality detector systems and sufficiently powerful personal computers were unavailable. Eventually, in 1999, the first dento-maxillofacial CBCT unit, the NewTom DVT 9000, designed by Attilio Tacconi and Piero Mozzo and produced by QR, Inc. of Verona, Italy, was introduced in Europe[2,3]. Today, new technological specifications and settings include multiple field of views (FOVs) and voxels that can better address a variety of specific tasks. There are also several hybrid machines offering CBCT imaging along with panoramic and cephalometric radiography. CBCT possesses a number of advantages over medical CT in clinical practice, such as lower effective radiation doses, lower costs, fewer space requirements, easier image acquisition, and interactive display modes such as mutiplanar reconstruction that are applicable to maxillofacial imaging. However, the disadvantages of CBCT include higher doses than two-dimensional imaging; the inability to accurately represent the internal structure of soft tissues and soft-tissue lesions; a limited correlation with Hounsfield Units for standardized quantification of bone density; and the presence of various types of image artifacts, mainly those produced by metal restorations[4-6].

CBCT is now commonly used for a variety of purposes in oral implantology, dento-maxillofacial surgery, image-guided surgical procedures, endodontics, periodontics and orthodontics. Whereas early CBCT devices were dedicated to implantology and dental imaging, today, applications extend to the face and skull base as a whole. Depending on the FOV used, CBCT images may show part or all of the nasal cavity, paranasal sinuses, airway, cervical vertebrae and temporal bone. In fact, specific ear, nose and throat imaging programs have been increasingly included in CBCT systems, suggesting that CBCT may at some point entirely replace medical CT imaging in certain otolaryngology-related applications[3]. CBCT has also been found to provide reliable and accurate 3D analysis of the upper airway that can be of help in assessing the presence and severity of obstructive sleep apnea[7]. Imaging of the temporal bone represents another promising area for CBCT, whose high-resolution and nearly artifact-free multi-planar reconstruction images make it possible to precisely assess the intra-cochlear position of the electrode, including visualization of each individual contact[8].

Concerns over liability issues related to CBCT remain unresolved. CBCT machines are increasingly being marketed specifically to orthodontists and implantologists or dentists who place implants in private practices. Unlike other advanced medical imaging systems, CBCT scanners are generally owned and operated by non-radiologists who lack the training necessary to interpret CBCT images. However, clinicians who order CBCT scans are responsible for interpreting the entire image volume, given the possibility that incidental findings - the likelihood of which increase when a larger head volume is included in the scan - may have significant health consequences for the patient[6]. There is no informed consent process or signature waiver that would allow the clinician to interpret only a specific area of an image volume. As a result, the clinician may be considered liable for a missed diagnosis, even one that falls outside the area of his/her expertise. In case of any questions regarding image data interpretation, referral to a specialist in oral and maxillofacial or medical radiology is recommended[6,9].

CBCT applications provide obvious benefits in the assessment of dentomaxillofacial region, however; it should be used only in correct indications considering the necessity and the potential hazards of the examination. Comparative radiation dosages should be weighed against diagnostic benefits in selecting the appropriate imaging modality for specific purposes. Future improvements in CBCT imaging can be expected to result in novel systems with better diagnostic abilities and lower effective doses[10].

Footnotes

P- Reviewer: Galiatsatos AA, Kanzaki H, Li YZ, Peker I, Rattan V S- Editor: Ji FF L- Editor: A E- Editor: Liu SQ

Conflict-of-interest: The Author declares no conflict of interest.

Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/

Peer-review started: December 11, 2014

First decision: January 8, 2015

Article in press: May 6, 2015

References

  • 1.Angelopoulos C, Scarfe WC, Farman AG. A comparison of maxillofacial CBCT and medical CT. Atlas Oral Maxillofac Surg Clin North Am. 2012;20:1–17. doi: 10.1016/j.cxom.2011.12.008. [DOI] [PubMed] [Google Scholar]
  • 2.Miracle AC, Mukherji SK. Conebeam CT of the head and neck, part 1: physical principles. AJNR Am J Neuroradiol. 2009;30:1088–1095. doi: 10.3174/ajnr.A1653. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Miracle AC, Mukherji SK. Conebeam CT of the head and neck, part 2: clinical applications. AJNR Am J Neuroradiol. 2009;30:1285–1292. doi: 10.3174/ajnr.A1654. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Acar B, Kamburoğlu K. Use of cone beam computed tomography in periodontology. World J Radiol. 2014;6:139–147. doi: 10.4329/wjr.v6.i5.139. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Scarfe WC, Li Z, Aboelmaaty W, Scott SA, Farman AG. Maxillofacial cone beam computed tomography: essence, elements and steps to interpretation. Aust Dent J. 2012;57 Suppl 1:46–60. doi: 10.1111/j.1834-7819.2011.01657.x. [DOI] [PubMed] [Google Scholar]
  • 6.Benavides E, Rios HF, Ganz SD, An CH, Resnik R, Reardon GT, Feldman SJ, Mah JK, Hatcher D, Kim MJ, et al. Use of cone beam computed tomography in implant dentistry: the International Congress of Oral Implantologists consensus report. Implant Dent. 2012;21:78–86. doi: 10.1097/ID.0b013e31824885b5. [DOI] [PubMed] [Google Scholar]
  • 7.Enciso R, Nguyen M, Shigeta Y, Ogawa T, Clark GT. Comparison of cone-beam CT parameters and sleep questionnaires in sleep apnea patients and control subjects. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010;109:285–293. doi: 10.1016/j.tripleo.2009.09.033. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Ruivo J, Mermuys K, Bacher K, Kuhweide R, Offeciers E, Casselman JW. Cone beam computed tomography, a low-dose imaging technique in the postoperative assessment of cochlear implantation. Otol Neurotol. 2009;30:299–303. doi: 10.1097/MAO.0b013e31819679f9. [DOI] [PubMed] [Google Scholar]
  • 9.Wright B. Contemporary medico-legal dental radiology. Aust Dent J. 2012;57 Suppl 1:9–15. doi: 10.1111/j.1834-7819.2011.01653.x. [DOI] [PubMed] [Google Scholar]
  • 10.Senel B, Kamburoglu K, Uçok O, Yüksel SP, Ozen T, Avsever H. Diagnostic accuracy of different imaging modalities in detection of proximal caries. Dentomaxillofac Radiol. 2010;39:501–511. doi: 10.1259/dmfr/28628723. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from World Journal of Radiology are provided here courtesy of Baishideng Publishing Group Inc

RESOURCES