Dear Editor,
Five-aminolevulinic acid (5-ALA)-derived fluorescence is approved for fluorescence-guided resections of malignant gliomas, relying on selective synthesis and accumulation of protoporphyrin IX (PPIX) within malignant glioma cells [5]. However, the first use of fluorescence for brain tumour surgery was in 1948 by G.E. Moore [3] using fluorescein sodium, a strongly fluorescing and non-toxic (apart from rare anaphylaxis [2]) compound. In malignant brain tumours with their inherent blood-brain barrier breakdown, fluorescein is extravasated and might serve to mark tumours.
Today, fluorescein sodium is again under scrutiny [1, 4] using a novel filter system by Zeiss (YELLOW 560) for the microscope. This filter visualises fluorescein and allows good background discrimination. Furthermore, fluorescein can be injected any time and is low in cost. Nevertheless, its use in brain tumour surgery is off-label and thus restricted to clinical studies.
Little is known about the best timing of i.v. fluorescein application before resection. Injecting fluorescein too early might result in unspecific propagation with oedema, whereas acute injections might be useful for detecting abnormally perfused tumour tissue. Levels in the blood will be high, especially with acute injections, leading to fluorescence of all perfused brain tissue. To our knowledge, such time-resolved information on the specificity of fluorescein are not available. Therefore, we conducted a small pilot study using two timing regimes in four patients pre-treated with 5-ALA (20 mg/kg, Gliolan; medac, Wedel, Germany), comparing early (35 min prior to durotomy, as previously described [4]) with acute injections of fluorescein (4 mg/kg, Fluorescein Alcon 10 %; Alcon, Freiburg, Germany). We used a Leica M530 OH6 (Leica Microsystems, Heerbrugg, Switzerland) equipped with a FL400 filter, freely interchangeable with an experimental band pass filter system for detecting fluorescein fluorescence without superimposed background information (Leica FL560) and allowing simultaneous visualisation of both fluorophores.
An example of fluorescein application prior to opening of the dura is given in the Fig. 1. This patient presented with a secondary malignant glioma in the right fronto-temporal region with patchy contrast enhancement. PPIX fluorescence was predominantly noted in one area, shining through the cortex, and was patchier in other areas. Fluorescein was found corresponding to porphyrin fluorescence, but was also visible in the dura, the cerebrospinal fluid (CSF) and weakly throughout the brain. After corticotomy fluorescein was found spreading through the arachnoid space away from the lesion, corresponding to regions of superficial coagulation for extending the corticotomy, along the corticotomy margins and in blood.
In a second patient, a patient with recurrent low-grade glioma, in whom fluorescein was given before opening of the dura, fluorescence was found in the brain adjacent to the tumour and in the dura itself. However, fluorescence appeared patchy or missing in the macroscopically detectable tumour. The tumour was not positive for 5-ALA fluorescence. At the end of the resection, after tumour removal had been confirmed by intra-operative ultrasound, diffuse green fluorescence was observed along all resection margins. Biopsies taken from this area were devoid of tumour.
In a third case, a patient with temporal glioblastoma, we attempted acute injection (Supplementary video) to determine whether fluorescein would correspond to porphyrin fluorescence. Fluorescein was visible in normally perfused brain. In the tumour cavity, fluorescein was in fact extravasated in the region of gross and necrotic tumour, but was not or vaguely visible in the marginal tumour. Blue light illumination for PPIX showed the adjacent white matter to carry strong red PPIX fluorescence, signifying tumour. We had a similar experience with a final patient after debulking of the main tumour mass and acute injection.
Overall, we observed no clear value of fluorescein in our small study, which we closed prematurely. Clearly, further work elucidating optimal timing and dosing of fluorescein is warranted.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Acknowledgments
We gratefully acknowledge technical support by Dr. Roger Spink, Leica Microsystems, Heerbrugg, Switzerland
Patient consent
Informed patient consent was obtained from all patients treated in the context of this study.
Conflict of interest
Walter Stummer has received consultant fees from medac, Wedel, Germany. All other authors report no conflict of interest.
References
- 1.Acerbi F, Broggi M, Eoli M, Anghileri E, Cuppini L, Pollo B, Schiariti M, Visintini S, Ori C, Franzini A, Broggi G, Ferroli P. Fluorescein-guided surgery for grade IV gliomas with a dedicated filter on the surgical microscope: preliminary results in 12 cases. Acta Neurochir (Wien) 2013;155:1277–1286. doi: 10.1007/s00701-013-1734-9. [DOI] [PubMed] [Google Scholar]
- 2.Dilek O, Ihsan A, Tulay H. Anaphylactic reaction after fluorescein sodium administration during intracranial surgery. J Clin Neurosci. 2011;18:430–431. doi: 10.1016/j.jocn.2010.06.012. [DOI] [PubMed] [Google Scholar]
- 3.Moore GE, Peyton WT, French LA, Walker WW. The clinical use of fluorescein in neurosurgery; the localization of brain tumors. J Neurosurg. 1948;5:392–398. doi: 10.3171/jns.1948.5.4.0392. [DOI] [PubMed] [Google Scholar]
- 4.Schebesch KM, Proescholdt M, Höhne J, Hohenberger C, Hansen E, Reimenschneider MJ, Ullrich W, Doenitz C, Schlair J, Lange M, Brawanski A. Sodium fluorescein-guided resection under the YELLOW 560 nm surgical microscope filter in malignant brain tumor surgery—a feasibility study. Acta Neurochir (Wien) 2013;155:693–699. doi: 10.1007/s00701-013-1643-y. [DOI] [PubMed] [Google Scholar]
- 5.Stummer W, Novotny A, Stepp H, Goetz C, Bise K, Reulen HJ. Fluorescence-guided resection of glioblastoma multiforme by using 5-aminolevulinic acid-induced porphyrins: a prospective study in 52 consecutive patients. J Neurosurg. 2000;93:1003–1013. doi: 10.3171/jns.2000.93.6.1003. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.